Loading...
HomeMy WebLinkAboutIn-Place Density Report_Test-0001-0012_7393482 1.12.21Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1 Building Pad Fill: House Pad. NW End of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 2 Building Pad Fill: House Pad. SW End of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 3 Building Pad Fill: House Pad. SE End of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 4 Building Pad Fill: House Pad. NE End of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 5 Building Pad Fill: House Pad. Center of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 6 Building Pad Fill: House Pad. SW End of Pad 1.0 Bottom of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 7 Building Pad Fill: House Pad. SE End of Pad 1.0 Bottom of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 8 Building Pad Fill: House Pad. NE End of Pad 1.0 Bottom of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks Pass: Density Pass Fail: Density Fail Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 1 9/24/20 20-255 (Modified) A --9.5 118.5 13.5 113.1 128.4 12 95 95 Pass 2 9/24/20 20-255 (Modified) A --9.5 118.5 14.5 111.2 127.3 12 94 95 Fail 3 9/24/20 20-255 (Modified) A --9.5 118.5 15.8 110.1 127.5 12 93 95 Fail 4 9/24/20 20-255 (Modified) A --9.5 118.5 14.8 111.3 127.8 12 94 95 Fail 5 9/24/20 20-255 (Modified) A --9.5 118.5 13.7 113.0 128.5 12 95 95 Pass 6 2 12/8/20 20-255 (Modified) A --9.5 118.5 13.8 114.8 130.6 12 97 95 Pass 7 3 12/8/20 20-255 (Modified) A --9.5 118.5 12.2 115.3 129.4 12 97 95 Pass 8 4 12/8/20 20-255 (Modified) A --9.5 118.5 13.6 114.8 130.4 12 97 95 Pass AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. Page 1 of 2 In-Place Density Report Test Method: ASTM D6938 Permit # SLC 2007-0678 Report Date: 1/11/2021 Client: Cole Construction Santa Rosa Beach, FL 32459 3295 W. County Highway 30A F Project: 2926 S. Header Canal Road 113-20-64-5517 Fort Pierce, FL 34945 2926 S. Header Canal Road Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone: 772-878-0072 Port St. Lucie Branch Test Information Test #Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 9 Building Pad Fill: House Pad. NW End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 10 Building Pad Fill: House Pad. NE End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 11 Building Pad Fill: House Pad. SE End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 12 Building Pad Fill: House Pad. SW End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie Remarks Pass: Density Pass Comments Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%)Remark 9 1/6/21 20-308 (Modified) A --10.0 110.5 14.3 108.0 123.4 12 98 95 Pass 10 1/6/21 20-308 (Modified) A --10.0 110.5 15.9 107.4 124.5 12 97 95 Pass 11 1/6/21 20-308 (Modified) A --10.0 110.5 15.4 106.8 123.2 12 97 95 Pass 12 1/6/21 20-308 (Modified) A --10.0 110.5 17.3 107.8 126.4 12 98 95 Pass AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. Page 2 of 2 In-Place Density Report Test Method: ASTM D6938 Permit # SLC 2007-0678 Report Date: 1/11/2021 Client: Cole Construction Santa Rosa Beach, FL 32459 3295 W. County Highway 30A F Project: 2926 S. Header Canal Road 113-20-64-5517 Fort Pierce, FL 34945 2926 S. Header Canal Road Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone: 772-878-0072 Port St. Lucie Branch This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Jan 11, 2021 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies.