HomeMy WebLinkAboutIn-Place Density Report_Test-0001-0012_7393482 1.12.21Test Information
Test #Test Location Elevation Reference
Gauge
Make / Model / SN / Calibrated Field Technician
1 Building Pad Fill: House Pad. NW End of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
2 Building Pad Fill: House Pad. SW End of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
3 Building Pad Fill: House Pad. SE End of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
4 Building Pad Fill: House Pad. NE End of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
5 Building Pad Fill: House Pad. Center of Pad 1.0 Bottom of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
6 Building Pad Fill: House Pad. SW End of Pad 1.0 Bottom of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie
7 Building Pad Fill: House Pad. SE End of Pad 1.0 Bottom of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie
8 Building Pad Fill: House Pad. NE End of Pad 1.0 Bottom of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie
Remarks
Pass: Density Pass
Fail: Density Fail
Comments
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
Test Results
Test #
Retest
Of Test Date Proctor ID Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry
Density (pcf)
In Place
Moisture
(%)
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
(%)Remark
1 9/24/20 20-255
(Modified)
A --9.5 118.5 13.5 113.1 128.4 12 95 95 Pass
2 9/24/20 20-255
(Modified)
A --9.5 118.5 14.5 111.2 127.3 12 94 95 Fail
3 9/24/20 20-255
(Modified)
A --9.5 118.5 15.8 110.1 127.5 12 93 95 Fail
4 9/24/20 20-255
(Modified)
A --9.5 118.5 14.8 111.3 127.8 12 94 95 Fail
5 9/24/20 20-255
(Modified)
A --9.5 118.5 13.7 113.0 128.5 12 95 95 Pass
6 2 12/8/20 20-255
(Modified)
A --9.5 118.5 13.8 114.8 130.6 12 97 95 Pass
7 3 12/8/20 20-255
(Modified)
A --9.5 118.5 12.2 115.3 129.4 12 97 95 Pass
8 4 12/8/20 20-255
(Modified)
A --9.5 118.5 13.6 114.8 130.4 12 97 95 Pass
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.
Page 1 of 2
In-Place Density Report
Test Method: ASTM D6938
Permit # SLC 2007-0678
Report Date: 1/11/2021
Client:
Cole Construction
Santa Rosa Beach, FL 32459
3295 W. County Highway 30A F
Project:
2926 S. Header Canal Road
113-20-64-5517
Fort Pierce, FL 34945
2926 S. Header Canal Road
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone: 772-878-0072
Port St. Lucie Branch
Test Information
Test #Test Location Elevation Reference
Gauge
Make / Model / SN / Calibrated Field Technician
9 Building Pad Fill: House Pad. NW End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
10 Building Pad Fill: House Pad. NE End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
11 Building Pad Fill: House Pad. SE End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
12 Building Pad Fill: House Pad. SW End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie
Remarks
Pass: Density Pass
Comments
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
Test Results
Test #
Retest
Of Test Date Proctor ID Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry
Density (pcf)
In Place
Moisture
(%)
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
(%)Remark
9 1/6/21 20-308
(Modified)
A --10.0 110.5 14.3 108.0 123.4 12 98 95 Pass
10 1/6/21 20-308
(Modified)
A --10.0 110.5 15.9 107.4 124.5 12 97 95 Pass
11 1/6/21 20-308
(Modified)
A --10.0 110.5 15.4 106.8 123.2 12 97 95 Pass
12 1/6/21 20-308
(Modified)
A --10.0 110.5 17.3 107.8 126.4 12 98 95 Pass
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.
Page 2 of 2
In-Place Density Report
Test Method: ASTM D6938
Permit # SLC 2007-0678
Report Date: 1/11/2021
Client:
Cole Construction
Santa Rosa Beach, FL 32459
3295 W. County Highway 30A F
Project:
2926 S. Header Canal Road
113-20-64-5517
Fort Pierce, FL 34945
2926 S. Header Canal Road
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone: 772-878-0072
Port St. Lucie Branch
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Jan 11, 2021 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.