ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
FLA/COM-97 Version 2.2
PROJECT NAME_00-006 HEALTHSOUTH PGA
ADDRESS: _SOUTH COMMERCE CENTER DRIVE
_PORT ST. LUCIE, FL
OWNER: HEALTH SOUTH
AGENT:
BUILDING TYPE: _Institutional (Health)
CONSTRUCTION CONDITION: New construction
DESIGN COMPLETION: _Finished Building
CONDITIONED FLOOR AREA: _3076
MAX. TONNAGE OF EQUIPMENT PER SYSTEM:
Form 40OA-97
PERMITTING OFFICE:
_Port St. Lucie
CLIMATE ZONE: 6
PERMIT NO:
JURISDICTION NO:_661200
A
NUMBER OF ZONES: 1
COMPLIANCE CALCULATION:
METHOD A DESIGN CRITERIA RESULT
-----------------
-------------- ------
A. WHOLE BUILDING 84.84 100.00 PASSES
PRESCRIPTIVE REQUIREMENTS:
LIGHTING
EXTERIOR LIGHTING
1075.00
1515.00
PASSES
LIGHTING CONTROL REQUIREMENTS
PASSES
HVAC EQUIPMENT
COOLING EQUIPMENT
1. EER
9.31
8.90
PASSES
IPLV
8.30
8.30
PASSES
HEATING EQUIPMENT
1. Et
1.00
N/A
AIR DISTRIBUTION SYSTEM INSULATION
REQUIREMENTS
1. With Insulated Roof
6.00
4.20
PASSES
REHEAT SYSTEM TYPES USED
NO REHEAT SYSTEM is USED
WATER HEATING EQUIPMENT
1. EF
0.89
0.89
PASSES
PIPING INSULATION REQUIREMENTS
1. Non -Circulating
1.00
1.00
PASSES
----------------------------------------------------------------------------
COMPLIANCE CERTIFICATION:
.I hereby certi
specification's
lation are in
Florida Energ
P,PARED BY
E:
that the plans and
veredqby this calcu-
li e w'th the
is �y ode.
./A 0-A .
I. -hereby certify that
in compliance with the
Efficiency Code.
this building is
Florida Energy
Review of the plans and specifica-
tions covered by this calculation
indicates compliance with the
Florida Energy Efficiency Code.
Before construction.is completed,
this building will be inspected
for compliance in accordance with
Section 553.908, Florida Statutes.
BUILDING OFFICIAL:
DATE:
OWNER/.&GENT•
DATE:
I1zereby certify(*)
Energy Efficiency C
►' ClOI�TFi'.M
that the system design is in compliance with the Florida
SIGNER
REGISTRATION/STATE
ARCHITECT c 1
MECHANICAL: ' " K.
PLUMBING
ELECTRICAL•
LIGHTING :
(*) Signature is required where Florida law requires design to be performed
by registered design professionals. Typed names and registration numbers may
be used where all relevant information is contained on signed/sealed plans.
61
BUILDING ENVELOPE SYSTEMS COMPLIANCE
CHECK
4Q'1.------GLAZING--ZONE 1------------------------------------------------ v-
Eievation Type U SC VLT Shading Area(Sgft)
-c---------------------- ---- ---- ---- -------------- ----------
North Commercial 1.09 0.95 0.92 Continuous Ove 240
East Commercial 1.09 0.95 0.92 Continuous Ove 240
South Commercial 1.09 0.95 0.92 Continuous Ove 154
West Commercial 1.09 0.95 0.92 Continuous Ove 154
Total Glass Area in Zone 1 = 788
Total Glass Area = 788
402.------WALLS--ZONE 1------------------------------------------------ ---
Elevation Type U Insul R Gross(Sgft)
----------------------------------------- ----- ------- -----------
North Stucco/8" CMU/Air+Furring/5/8 GY 0.2 0 1040
East Stucco/8" CMU/Air+Furring/5/8 GY 0.2 0 928
South Stucco/8" CMU/Air+Furring/5/8 GY 0.2 0 732
West Stucco/8" CMU/Air+Furring/5/8 GY 0.2 0 928
` Total Wall Area in Zone 1 = 3628
Total Gross Wall Area = 3628
403.------DOORS--ZONE 1------------------------------------------------ ---
Elevation Type U Area(Sgft)
--------------------------------------------------- ----- ----------
East 1-3/4 Steel Door -Polyurethane core (24 0.29 5
West 1-3/4 Steel Door -Polyurethane core (24 0.29 3
Total Door Area in Zone 1 = 8
Total Door Area = 8
404------- ROOFS --ZONE 1------------------------------------------------ ---
Type Color U Insul R Area(Sgft)
------------------------------------ ------ ----------------------
CLGTIL/AIR/MTDECK/R-10/BUR/.073 Medium 0.073 10 3076
Total Roof Area in Zone 1 = 3076
Total Roof Area = 3076
405------- FLOORS -ZONE 1------------------------------------------------ ---
Type Insul R Area(Sgft)
-----------------------------------------------------------------
Slab on Grade/Uninsulated 0 3076
Total Floor Area in Zone 1 = 3076
Total Floor Area = 3076
406.------INFILTRATION -------------------------------------------------- ---
Infiltration Criteria in 406.1.ABCD have been met. I CHECK
MECHANICAL SYSTEMS
CHECK
----------------------------------------------------------- ---- ---
HVAC load sizing has been performed. (407.1.ABCD)
407.- ----COOLING SYSTEMS----------------------------------------------- ---
Type No Efficiency IPLV Tons
--------------------------- ------------- -------------------
1. Air Cooled ( >= 65,000 Btu/h 2 9.31 8.3 5.79
4(18------- HEATING SYSTEMS ------------------ - ---------------------------- ---
Type No Efficiency BTU/hr
-------------------------------- ---------------------------
1,,. Electric Resistance 2 1 27105
409.------VENTILATION --------------------------------------------------- ---
ICHECK
Ventilation Criteria in 409.1.ABCD have been met.
4 1-0'.=----AIR DISTRIBUTION SYSTEM---------------------------------------- ---
---------------------------------------------------------------- CHECK ---
Duct sizing and design have been performed. (410.1.ABCD) I
AHU Type Duct Location R-value
----------------------------------------------------------------
1. Packaged Constant Volume With Insulated Roof 6
CHECK
------------------------------------------------------ ---- ---
Testing and balancing will be performed. (410.1.ABCD)
411.-----PUMPS AND PIPING -ZONE ----------------------------------------- ---
Basic prescriptive requirements in 411.1.ABCD have been met.
PLUMBING SYSTEMS
411------ PUMPS AND PIPING -ZONE 1------------------------------- ------ ---
Type R-value/in Diameter Thickness
_
---------------------------
------------- 7----------
1. Non -Circulating 4 0.5 1
412.-----WATER HEATING SYSTEMS -ZONE 1----------------- -_---------------- ---
Type Efficiency'StandbyLoss InputRate Gallons
---------------
1. <=12 kW 0.89 0 4.5 30
ELECTRICAL SYSTEMS
CHECK
413------- ELECTRICAL POWER DISTRIBUTION---------------------------- ----- ---
Metering criteria in 413.1.ABCD have been.met.
414.-----MOTORS ----------------------- =--------------------------- ----- ---
Motor efficiencies in 414.1.ABCD have been met.
415------ LIGHTING SYSTEMS -ZONE 1---=----------------------------------- ---
Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)
---------- ----------------- ----------------- --- ---- - - ----------
Occupation 1 On/Off 3 None 0 4920 3076
Total Watts for, Zone 1 = 4920
Total Area for Zone 1 = 3076
Total Watts = 4920
Total Area = 3076
CHECK
Lighting criteria in 415.1.ABCD have.been met.
16. Operation/maintenance manual will be provided to owner.(102.1)
---------------- ------------------------------------------------------------
fo
14
Air S stem Sizin Summa for 00-006 HSC PGA RESERVE
Pr iect Name: 00.006 HSC-PGA RESERVE 02/11/00
i'srjepared by. RPJ INC.
12:05 PM
--;-System Information
System Name 00-006 HSC PGA RESERVE
Equipment Class PKG ROOF Number of Zones 1
System Type SZCAV Floor Area 3076.0 ftz
Sizing Calculation Information
Zone and Space Sizing Method:
Zone CFM Peak zone sensible load
Space CFM Coincident space loads
Central Cooling Coil Sizing Data
Total coil load
10.3 Tons
Sensible coil load
8.1 Tons
Coil CFM at Aug 1500
3786 CFM
Max possible CFM
3766 CFM
Design supply temp.
55.0 "F
ftzlfon "
300.0
BTU/hr/ftz
40.0
Water flow @ 10.0 °F rise
- gpm
Central Heating Coil Sizing Data
Max coil load 60382 BTU/hr
Coil CFM at Des Htg 3786 CFM
Max possible CFM 3786 CFM
Water -flow @ 20.0 °F drop - gpm
Supply Fan Sizing Data
Actual max CFM at Jul 1600 3786 CFM
Staridard CFM 3783 CFM
Actual max CFM/ftz 1.23 CFM/ftz
Outdoor Ventilation Air Data
Design airflow CFM 500 CFM
CFM/ftz 0.16 CFM/ftz
Calculation Months Jan to Dec
Siang Data Calculated
Load occurs at
Aug 1600
OA DB / WB
91.0178.0 °F
Entering DB / WB
79.1 / 65.2 "F
Leaving DB / WB
55.4/54.1 °F
Coil ADP
52.7 °F
Bypass factor
0.100
Resulting RH
44 %
Zone T-stat Check
1 of 1 OK
Load occurs at Des Htg
BTU/hr/ftz 19.6
Ent. DB / Lvg DB 66.0180.8 °F
Fan motor BHP 1.65 BHP
Fan motor kW 1.23 kW
Fan static 1.50 in. wg.
CFM/person 20.00 CFM/person
Carrier Hourly Analysis Program v4.00 Page 1
Zone Sizin Summa for 00-006 HSC PGA RESERVE
Project tine: 00.006 HSC-PGA RESERVE 02/11/00
f8reoared bv: RPJ INC. 12:05 PM
-F,izing Calculation Information
Zone and Space Sizing Method:
Zone CFM Peak zone sensible load Calculation Months Jan to Dec
Space CFM Coincident space loads Siang Data Calculated
Zone Sizina Data
Maximum
Design
Minimum
Time
Maximum
Cooling
Air
Air
of
Heating
Sensible
Flow
Flow
Peak
Load
Zone Name
MBH
CFM
CFM
Load
MBH
Zone 1
80.9
3748
3748
Jul 1600
49.7
Zone Terminal Sizing Data
No Zone Terminal Siang Data required for this system
Soace Loads and Airflows
'
Cooling
Time
Air
Heating
Zone Name /
Sensible
of
Flow
Load
Space Name
Mult
MBH
Load
CFM
MBH
Zone 9
00-006 HSC PGA RESERVE
1
80.9
Jul 1600
3748
49.7
r;.
Carrier Hourly Analysis Program v4.00 Page 2
Air System Design Load Summary for 00-006 HSC PGA RESERVE
11ro0 t Name: 00.006 HSC-PGA RESERVE 02/11/00
Prepared by: RPJ INC. 12:05 PM
�.f
DESIGN COOLING iDESIGN
HEATING
COOLING DATA AT Aug 1500
COOLING OA DB / WB 91.0 •F / 78.0 •F !HEATING
HEATING DATA AT DES HTG
OA DB / WB 43.0 •F / 36.1 -F
ZONE LOADS
Details
Sensible
BTU/hr
Latent
BTU/hr
Details
Sensible
BTU/hr
Latent
BTU/hr
Solar Loads
772 ft2
25187
-
772 ft2
-
-
Wall Transmission
2835 ft2
12705
-
2835 ft2
15395
Roof Transmission
3076 ft2
14937
-
3076 ft2
6093
Glass Transmission
772 ft2
116161
-
772 ft2
22971
Skylight Transmission
0 ft2
0
-
0 ft2
0
-
Door Transmission
21 ft2
86
-
21 ft2
170
Floor Transmission
3076 ft2
0
-
3076 f12
3754
Partitions
918 918 ft2
555
-
918 ft2
1340
-
Ceiling
0 ft2
0
-
0 ft2
0
Overhead Lighting
3426 W
9474
-
0
0
Task Lighting
0 W
0
-
0
0
-
Electric Equipment
0 W
0
-
0
0
PeopJe
25
4575
5125
O
0
0
Infiltration
-
0
01
0
0
0
Miscellaneous
-
0
0
-
0
0
Safety Factor
0%/0%
0
01
0°%
0
0
>> 7Utal Zone Loads
79235
5125
49724
0
Zone Conditioning
-
84645
5125
-
49797
0
Plenum Wall Load
0°%
0
-
0
0
-
Plenum Roof Load
0%
01
0
0
-
Plenum Lighting Load
0%
01
0
0
-
Retum Fan Load
3786 CFM
0l
-I
3748 CFM
0
-
Ventilation Load
500 CFM
7379
208851
500 CFM
14297
0
Supply Fan Load
3786 CFM
4210
-
3786 CFM
-421
-
Space Fan Coil Fans
-
0
-
-
0
-
Duct Heat Gain / Loss
1°%
792
-I
1%
497
-
>> Totals stem Loads
97027
260101
60382
0
Central Cooling Coil
-
970271
250141
0
0
Central Heating Coil
-
0
-
-1
60382
-
>> Total Conditioning
970271
2601411
603821
0
Key:
Positive values are cig loads
Negative values are htQ loads
I Positive values are htg loads
Negative values are cig loads
Carrier Hourly Analysis Program v4.00 Page 3
Space Design Load Summary for 00-006 HSC PGA RESERVE
P/bject NaPne: 00.006 HSC-PGA RESERVE 02/11/00
PFepared by: RPJ INC. 12:05 PM
im
TABLE 1.1.A. COMPONENT LOADS FOR SPACE " 00-006 HSC PGA RESERVE
" IN ZONE " Zone 1 "
DESIGN COOLING I
DESIGN HEATING
COOLING DATA AT Jul 1600 1HEATING
OA DB / WB 90.6 'F / 77.9 •F JOA
OCCUPIED T-Sc 75.0 ®F
DATA AT DES HTG
DB / WB 43.0 •F 136.1 -F
OCCUPIED T-STAT 70.0 OF
SPACE LOADS
Details
Sensible
BTU/hr
Latent
BTU/hr
Details
Sensible
BTU/hr
Latent
BTU/hr
Solar Loads
772 ftz
26907
-
772 ft2
-
-
Wall Transmission
2835 ftz
13526
-
2835 ft2
15395
-
Roof Transmission
3076 fP
13921
-
3076 fie
6093
Glass Transmission
772 ft2
' 115191
772 ft2
0
Skylight Transmission
0 ft2
01
0 ft2
0
Door Transmission
21 f12
851
21 f12
170
-
Floor Transmission
3076 ft2
0
-
3076 ft2
3754
-
Partitions
918 ft2
550
-
918 ft2
1340
-
Ceiling
0 ft2
0
0 ft2
0
-
Overhead Ughling
3426 W
9619
-
0
0
-
Task I.Ighting
0 W
0
-
0
0
-
Electric Equipment
0 W
0
-
0
0
People
25
4770
51251
0
0
0
Infiltration
-
0
0
-
0
0
Miscellaneous
-
0
0
-
0
0
Safety Factor
0% / 0%
0
01
0%
01
0
>> Total Zone Loads
80898
6125
497241
0
TABLE 1.1.B. ENVELOPE
LOADS FOR SPACE " 00-006 HSC PGA RESERVE
" IN ZONE
" Zone 1 "
Area
ft2
U-Value
BTU/hr/ft°/F
Shade
coeff.
COOLING
TRANS
BTU/hr
COOLING
SOLAR
BTU/hr
HEATING
TRANS
BTU/hr
N EXPOSURE
WALL
800
0.201
-
2966
-
4344
WINDOW 1
240
1.102
0.9501
3581
4889
7141
E EXPOSURE
WALL
816
0.201
-
5215
-
4431
WINDOW 1
70
1.102
0.9501
1044
2882
2083
DOOR
14
0.300
-
57
-
113
DOOR GLASS
28
1.103
0.950
418
592
834
S EXPOSURE
WALL
512
0.201
-'
1968
-
2780
WINDOW 1
220
1.102
0.950
3283
4372
6546
W EXPOSURE
WALL
707
0.201
-
3376
-
3839
WINDOW 1
200
1.102
0.9501
2984
13837
5951
DOOR
7
0.300
-1
281
57
DOOR GLASS
14
1.103
0.9501
2091
417
H EXPOSURE 0 DEGREE SLOPE
ROOF
3076
0.073
-1
13921
-
6093
Carrier Hourly Analysis Program v4.00 Page 4
2400 Rhode Island Ave
Fort Pierce, Florida 34950
ST. LUCIE COUNTY FIRE DISTRICT
BUREAU OF FIRE PREVENTION
PLAN REVIEW
TYPE OF PERMIT
Telephone (561)-462-2312
Fax:: (561)-462-2323
(X) New Construction ( ) Tenant Improvement ( ) Addition ( ) Renovation/alteration ( ) Shell Only
Jurisdiction: St Lucie County
Occupancy: HEALTH SOUTH/PGA LEARNING CTR
Address: 8565 Commerce Center Dr
Contractor: WPR Contracting
.Contractors address: 1565 N Park Drive #103
Arch itect/Engineer: Jaime Lichi, Architects
Building owner: PGA Golf Development Inc
Occupancy type: Business
Gross sq. ft. 3014 sq ft
Occupant load:
Construction type ( NFPA-220) Type:
F.P.B. B-00-59
Building Dept: 20020645
Number of stories: 1
Phone # 954-349-9910
City: Weston, FL Zip: 33326
Phone: 954-389-9499
Review date: 3-16-00
Automatic sprinklers: Existing
Net sq ft:
Based on:
SBCCI: Type: IV
NOTE
1. All revisions must be in compliance before the final inspection, or so noted.
2. The Fire Marshal required 24 hour notice on all inspections.
3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
4. Failed inspections require payment of fee prior to scheduling of any further inspections.
5. Permit fees are required to be paid in full prior to any inspections.
6. A copy of the required revision/s have been transmitted to the Architect ( ) Contractor ( ).
REVISIONS REQUIRED
1. A separate permit is required for alterations or additions to the fire sprinkler system.
Reviewed By:
Tony Liento
Date: March 16, 2000
Jaime lichi and associates architects, inc.
City Of Port St Lucie
ph.(954)389-9499 fax (954)389-8468
Building and Zoning Department
Re:
HealthSouth PGA
7-26-2000
Dear sir:
Please note that I have approved WPR contracting the installation of a dryer vent thruough a 4" chase wall outside
the block wall (inside the building as shown) into the mansard roof having a waterproof exhaust cap as shown.
WATER PROOF DRYER _
CAP W/ INSECT SCREEN
TRUSS SYSTEM
�CHEMENT
MANSARD ROOF
DRYER VENT IN 4' STUD
WALL ADJACENT 1"0 BLOCK WALL
EXTERIOR WALL
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR lfim mhine
REVIEWED B
DATE I
7/
4t*Z00 zc /045
1
SUM-22-00 12:40 Pf4 STLUCIEC0S4LIDWr-:,STE 5614626987
w
Serf 9}P: WR CONTRACTI40 INC, ; 854 349 3082 ; Jun42-00 12;18PM; Page Vs
S
ii
REQUEST FOR 30 DAY TEMPORARY POWER RKLEASE
DATE: //�� $T. LUCIE COUNTY BI.nG. & ZONING
,.,.,,. 4f? "" :a - O C� MG VIRGINIA AVE
PERl1IIT NUMBER: FORT PIERCE, FL 349524652
65
PROPERTY AX)DRF:SS: JUN 2
fa rrti f r L,a _ [ e Or 1,A41,1
THE UlYI1ERSYG..'�TED HEREBY REQUEST RELEASE OFEM(CTRICAL POWER TO
THE ABOVE DESCRIBED PROPERTY, FOB A PERIOD NOT TO EXCEED THIR'TY (30)
DAYS, PnR THE PVRPOSIE OF TE8TING SYSTEMS AND - EQUIPMENT IN
PREPARATION FOR VINAL INSPEC.TioN, fN CONSIDERATION OF APPROVAL OF'
T'W- RIMOVESI' WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS:
L This temporary power release In requetted for the above stated purpusc only,
and there will be no occupancy of any type, other than tbat permitted by
construction during this dale period.
2. As witness by our signatures, we hereby agree to abide by all terms and
conditions of this agreement, ineludi-mg Building Division Policy, which is
Incorporated herein by-erereacc
3. All conditions and requiremeola Listed in the attached document entitled
"Requirements for 30 Day Power for Testing" have been fulClled and the
promises is ready for compliance Lusp"tlotl.
VVE HEREBY RELEASE AND AGREE TQ HOLD HARMLESS* ST. LIfCIE COUNTY,
AND TIMJR EMPLOYEES FROM ALL LIABILITIES AND CLAIMS OF ANY TYPE OF
MATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS
TRANSACTION, INCLEMING ANY DAMAGE,q WHICEI MAY BE INCURRED DEJE TO
TIa"ISCONNECTION OF ELECTRICAL POWER IN THE EVENT OF VIOLATION OF
T AGREEME1i'1— A
i77V7 . U) PP- CO<LA-CFt 4&-, 1 d
SICNATURE
aA SIGNATURE ��
P.03
RPJ_Inc.
CONSULTING ENGINEERS
June 22, 2000
St. Lucie County Building Department
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Attn.: Mechanical Department.
Re: Health South @ PGA
8565 So. Commerce Center Drive
Port St. Lucie, Florida
Permit No. 20020645
Gentlemen,
Please be advised that the supply main ducts were transitioned as per attached sketch to
clear ey�4tin%fire atninkler lines.
Attachment
RPJ/hp
4207 Salzedo Street • Coral Gables, FL 33146 • Phone: (305) 441-1523 • Fax: (305) 567-9476
E-Mail: rpjmep0bellsouth.net
J
A � � �►,c �
drou oo iOjc\,, iWc 'h.w4,
hL UAW -IL
z
u
Im
V
a
D
n
n
o-
a
n
n
N
m
3
r
o
i
z
w
c
0
0
ROOFTOP A/C UNIT SCHEDULE
UNIT DESIGNATION
RTU-1
RTU-2
AREA SERVED
SEE PLANS
SEE PLANS
LOCATION
ROOF
ROOF
UNIT SEER
10.0
9.0
UNIT TYPE
ROOFTOP
OW
ROOFTOP
DOWFLOW
REFRIGERANT TYPE
R-22
R-22
ELECTRICAL SERVICE AVAILABLE
208/3/60
208/3/60
TOTAL AIR, CFM
2000
2400
OUTSIDE AIR, CFM
250
250
w
EXTERNAL STATIC PRESSURE. IN. OF WATER
--
--
kn
<
FAN SPEED RPM
—
--
BHP (MAX.) / FLA.
1.5/5.9
2.0 / 5.8
ENTERING AIR TEMP., F DB/WB
80/67
--
LEAVING AIR TEMP., F DB/WB
FACE VELOCITY, FPM (MAX.)
--
--
TOTAL CAPACITY, MBH
60.8
78.2
SENSIBLE CAPACITY, MBH
45.3
57.6
TYPE AND THICKNESS
i" T.A.
i" T.A.
J
FACE AREA, SQ. FT. (MIN)
--
NO. OF COMPRESSORS
1
1
CAPACITY REDUCTION. PERCENT EA.
100%
100%
COMPRESSOR RPM. (MAX.)
--
--
MOTOR POWER UNIT, KW (MAX.)
--
--
TOTAL FULL LOADAOCKED MOTOR AMPS
17.5/110.0
20.9/142.0
TYPE OF FAN & NO.
PROPELLER — 1
ROPELLER-1
AMBIENT AIR TEMP., F
95
95
oFAN
MOTOR HP. EACH
1/4
1/4
0
k'
MAX. CONDENSING TEMP., F
--
--
TYPE
ELECTRIC STRIP
ELECTRIC STRIP
a
HEATING CAPACITY. BTUH
--
--
=
NO. OF STAGES & KW/STAGE
1 — 7.9
1-7,9
PREFAB ROOF CURB 14" HIGH
NO
NO
SEACOAST CONSTRUCTION
YES
YES
a
SURE TRIP, HOT GAS REHEAT
--
--
VIBRATOR ISOLATOR TYPE
INTERNAL
INTERNAL
MIN. STATIC DEFLECTION, IN.
--
--
OPERATiNG WEIGHT, LBS.
395
470
DESIGN MANUFACTURER
CARRIER
CARRIER
MODEL NO.
50TJO06-5
50TJD07-5
MCA/MOCP
34.7/40
36.1/45
REFRIG. CHARGE
--
--
1. GENERAL
A. ALL WORK SHALL be done in accordance with the tndarld Building
Code and with all applicable regulations.
B. DRAWNGS: Refer to all drawings for coordinationifo
theHVAC work.
C. ARRANGE AND PAY for all permits, licenses, inspections and tests.
Obtain the required certificates and present to owner.
D. GUARANTEE: The completed installation shall be fully guaranteed
against defective materials and/or improper workmanship for a
minimum of one year for material and labor. Compressors shall
be guaranteed for a period of five years.
2. SHOP DRAWNGS: Contractors shall submit for approval, within 30 days
after signing contract, a minknum of five copies of fully descriptive
literature, including but not limited to: air outlets.
3. DESIGN PARAMETERS:
A Outdoor design temperature (Summer): 91 F DB and 79 F WB
B. Outdoor design temperature (Wnter): 45 F
C. Indoor design temperature (Summer): 78 F DB
D. indoor design temperature (Wnter} 72 F DB
4. ALL THERMOSTATS SHALL have heating mode maximum setting of 75 F, and
cooling mode minimum setting of 70 F. The thermostat shall be arranged
to prevent the simultaneous operation of heating and cooling.
5. ELECTRICAL CONTROLS and power wiring: Under electrical contract.
6. EQUIPMENT SPECIFIED BY manufacturer's number shall include all
accessories, controls, etc., listed in the catalog as standard with the
equipment. Optional or additional accessories shall be furnished as
specified
7. MATERIALS:
A. DUCTWORK:
a. All supply air ductwork shall be 1 1/2" inch thick fiberglass
ductboard, fabricated and installed as per latest edition
of SMACNA °Fibrous Glass Duct Manual.' R-6.0 min.
b. All toilet exhaust ductwork shall be galvanized sheet metal
or aluminum duct not lighter than 26 gage.
c. All duct dimensions are clear inside dimensions.
d. Flexible insulated ductwork with 1 1/2" thick fiberglass insulation
with FRK vapor barrier, class I air duct, U.L listed. R-6.0 min.
e. Dryer ductwork: 26 ga. min, galvanized steel, having a
smooth interior surface with pints running in the direction
of airflow and without sheet metal screws or other fasteners
in the air stream. Maximum length shall not exceed 25 feet.
wall caps shall be provided with backdraft damper.
8. PROVIDE metal round fittings with damper operator at all flexible duct
connection to supply duct.
9. TEST & BALANCE: Contractor shall test & balance all ventilation & air
conditioning systems of Test & Balance report to owner for approval.
10. CONTROLS: Air Conditioning System shall be started & stopped thru individual
thermostat. Individual thermostat shall start/stop supply fan & activate
cooling/heating system as selected. A activation of unit duct smoke
detectector shall sound alarm bell, and indicating light, and shag stop
fan coil unit.
AIR DISTRIBUTION SCHEDULE
DESIGN MANUFACTURER
SIMBOL USE
TYPE
ACCESORIES
& MODEL Mo.
O SUPPLY AIR
LOUVERED FACE
DIFFUSERSMODULE
O.B.D.
PRICE AMDA
2424
o RETURN AIR
LOUVERED CEILING
---
PRICE 70
FLASHING & COUNTERFLASHING
O/A INTAKE W/ VOLUME DAMPER
& BIRD SCREEN
R TU
ROOF CURB • ..
III 11 I I I_ STEEL JOIST
SUPPLY DUCT f
(RETURN DUCT BEHIND) J SMOKE DETECTOR SUSPENDED CEILING
(WHERE SPECIFIED)
TYPICAL AZC MOUNTING DETAIL
NO SCALE
SECURE UNIT TO ROOF CURB
WITH 3/8"0 BOLTS 6' O.C.
(MIN. TWO PER SIDE)
UNIT MOUNTED ON
PRE —FABRICATED ROOF CURB
UNIT CURB MOUNTED ON TOP CHORD
OF STEEL JOIST. W 3l8" 0 BOLTS TO
UPPORT O EVERY 6 —0 O.C.
MIN. TWO PER SIDE)
ROOF INSULATION
METAL DECK
VENTII
UNIT DESIGNA
AREA SERVED
OPERATING W
LOCATION
FAN TYPE
LL
TOTAL AR, C
DRIVE TYPE
FAN WHEEL T
FAN Tip SPEE
FAN SPEED, I
TOTAL STATIC
FAN MOTOR I
FAN MOTOR S
STARTER FUR
ELECTRICAL S
MASONARY Of
DESIGN MANL
MODEL NUME
j0
a
SERVICE SWf
SMOKE DETE
FIRE DAMPEf
CONSTRUCTI(
MULTiBLADE
BIRDSCREEN
SOLID STATE
THERMOSTAT
FACTORY FAE
FILTER AND f
AIR DUCT (SEE PLAN VIEW)
LOW FRICTION LOSS
BRANCH TAKE —OFF FITTING
METAL ROUND FITTING
QUADRANT OPERATOR TO BE
OUTSIDE INSULATION
PROVIDE INSULATION GUARD
WHERE NECESSARY
SEAL JOINT W/
DUCT SEALER AND
TAPE
AIR JnFLLOW
V
`\\\ AIR FLOW
INSULATED FLEX. DUCT
SEAL JOINT WITH DUCT
SEALER AND TAPE
DIFFUSER WITH OPPOSED �V
BLADE DAMPER INSULATE DIFFUSER TOPS.
ADAPTOR ROUND TO SQUARE
IF REQUIRED —
FLEXIBLE DUCT CONNECTION DETAIL
N.T.S.
NUt uurl;
CEILING P1F,
SCALE 11400
e1'-O"
OUTDOOR AIR CALCULATIONS AS PER ASHRAE 62-89
AREA
DESIGNATION
FLOOR
AREA, SF (.)
PERSONS
1000 SFPERSONS
TOTAL
CFM
ERSOREQUIRED
:LFjL
CFM
CFM
PROVIDED
SYSTEM
DESIGNATION
THERAPY
1198
20
24
15
--
360
OFFICES
955
7
7
20
140
TOTAL
500
500
RTU-1,-2
(a) NET OCCUPIABLE AREA
ST. LUCIP Gwn r
BUILDING Dlvlslo
RIgv1LTWZD
!OR PLIA
ItIVILWID
MUif it KRFT ON JOB
R,J, Inc.
NA9Ch
PE # 16395
4207 SALZEDO STREET
CORAL GABLES, FL 33146
PHONE: (305) 441-1523
FAX: (305) 567-9476
cfi
,_ .... .m, .-.. MINe.6. ._.. . .. < -,. ... i �
1111111 .. ,. n ......, ' w .,.s $u.......,_.J1,
,
1,�Ya_.+'
'. G
"£ M
v
a;prtF ��Ef
«
hr „' h�
{
(.. .
ti
M.
c v;: .; Y. .. n
d. .. i. ei.
.. F .!
, .... _ .. � .n. .... .:«.5. t �.� ,;.. . , n,:. .s. , .. ..
.:...... . .v n.. ic-u.... -:.. .. .: ., .., ..
N✓ ... i` .N .. ,.s.. ...e., i1
.e,. x. .. ,... v!Y
..w �'. .*'r.."., S %+. .' .x�.-., x�9i. F f ,.a.
..a:. '::„r d .. ;n_ i s
, ,n .. ,a:.... xis-.r ,.> ;.... i ..t..
kS t Se. fYs,k. �'$.{
T.. y+%. P `_�µ<y St :4".t
Y �... ...
al:.. aY y( �'�,
n '...1
?-
GENERAL NOTE5:
I. All general notes given herein apply to all allied trades for the project amended elsewhere
to include isolated conditions.
2. Items and Features are indicated or noted in one prime view or area of a drawing. Coordinated all
auxiliary views and provide these items and features not repeated as intended in the prime view
presented
3. All existing dimensions given on the construction documents were give Finish to Finish .
Contractor shall verify all existing conditions before beginning work , Any discrepancies that may
conflict with work to be carried out are to be brought to the architect's attention as soon as
possible,
4. All nominal layout dimensions given in new construction are to rough walls, partitions and
structure.
5. Coordinate ceiling grid with electrical layout and mechanical distribution grills.
6. The physical characteristics of any equipment substituted and approved as equal shall have
identical characteristics and properties, fit in spaces provided, and satisfy all required functional
and aesthetic requirements. Coordinate all changes with affected trades.
1. Factory pressure treat all wood in contact with masonry or subject to constant moisture or vermin
attack Field repair all surfaces after any work is done, and replace any existing rotted wood.
a. Some connections indicated on this documents are schematic and shall be secured to all
components rigidly to structure and each other, Use fasteners designecl For their specify purpose only
and as per manufacturer recommendations.
9. Do not scale drawings or make assumptions of size by visual reference. Report any missing
dimensions to the Architect.
10. Manufacturer's name and model are given to establish a minimum required function, performance,
and aesthetic value. Other products conforming to these documents may be presented to the
Architect for approval.
II. Finish materials and colors patterns and textures shall be coordinated by the owner.
12, Obtain clarification and interpretation to these documents and specifications, including additional
detail; directly from Architect
13. Demolition work to include removal of all existing structures necessary to complete new
Facilities. Refer to documents for location of work
14. Alteration of work as shown to include cutting and patching existing partitions, ceilings, floor
and the work of other trades. Cut, remove and patch after refinish existing construction as c lied
for on the documents, so as to leave work complete and in satisfactory condition. Surfaces f
existing work that will be in contact with new wore, to be prepared to receive bond neatly and
carefully, materials and methods to match existing adjacent work I
15. Exercise extreme caution in the protection of e istine adjacent work Damage to existing areas
which are to remain are to be their original con ition at Contractor's expense.
16. Were work is done above existing ceilings. Car fully remove existing panels and store them as per
manufacture's recommendations in a protected a ea.
17. Waste material and rubbish from alteration operations shall be removed from site as rapidly as
possible and shall not be allowed to accumulate on the premises. Disposal of material shall be at
the discretion of the Contractor, Open fires will not be permitted for disposal of waste. Contractor
shall provide an exterior area to collect demol shed material no to be reused.
la, Protect all concealed utilities. Prior to demolition of any structure, General Contractor must
remove portions of ceiling and open chases in real of said building floor to allow inspections of
these spaces. Electrical subcontractor shall ca anc/ or reroute existing active utilities as required.
Electrical Lines or similar hazards with which a worker might come in contact, shall be encased or
19, 2grounded.
11 work is to be done in accordance with local' codes and requirements. The contractor is td bid
the work to conform with local code requirements.
20. Execution of demolition and alteration of work` hall progress in a manner as not to interfere with
the safety and convenience of those employed in and about premises. Features of protectio of,
employees and public shall comply with minimum s andards of the Florida Industrial Commission
and all applicable codes and ordinances.
21. At the end of the days work, cover all work likely to be damages. Any work damaged by failur to
provide protection shall be removed and replaced with new work at the Contractor's expense.
22, Contractor agrees to hold Owner, Architect, and or any of their employees or agents, harmless
From any and all damage and claims which may raise by reason of any negligence on part of the
Contractor, any of his subcontractors, and/ or subcontractor materials and equipment supplier
and/ or its employees or agents; in performance of this contract.± and, in case any action is b ought
therefore against Owner, Architect, and/ or any of their employees or agents reserve the right to
defend such action and charge all costs thereof to the Contractor.
N
0
c
n
COMMERCE CENTER DR.
Slfi LOCT-,-[ION
NORTH
leg R
RY LUCIE OUNtV
BUILDING DIVISION
REVIEWED
�.HM
FOR co
F ��
AND vEnMrc
no RKPW" M WILL BEUM " KEPT ON Joe OR
'108 MADE
1
` ST. LUCIE COUNTY
FIRE DISTRICT
f >
II REVIEWED FOR COMPLIANCE
AND
SURTUCT TO FINAL FIELD INSPECTION
V. DATE: 3 -/G - OG
SEE ATTACHED REVISION SHEET
2400 Rhode Island Ave. Tel: (561) 462.2312
' t.,Pierce, FL 34�50 Fax: (56I) 462-` 5s 13
F
CIO
UU
CD
Mai
0
W
=
�
i
01
CA
vw
vw vw
vw
VY
AT
10'-0"'
02
CA
vw
vw vw
vw
VY
AT
10'-0"
03
CA
cw
�w cw
cw
VY
AT
10,_O"
SLIP RESISTANT
12
CA
cw
GW GW
GW
VY
AT
10'-0"
11
CA
cw
cw ow
Gw
VY
AT
10'-0"
09
VCT
cw cw
VyAT
cw
10'-0"
08A
VCT
Gw
GW GW
Gw
VY
AT
10'-0"
07
CA
cw
Gw
VY
TO 5'-0" MIN
WAINSCOT TO W-O" MIN
CAULK
2- METAL STUDS
AT HEAD AND JAMB
SOLID CORE DOOR
HOLLOW METAL FRAME
3/4' UNDERCUT
PER MECHANICAL
5/8' GYP WALLBRD.
BOTH SIDES
ICAULK---\ L L
2-METAL STUDS —I
AT HEAD AND JAMB
SOLID CORE DOOR —
MR,�'yPLfiWG+HIN
DOOR SCHEDULE
NUMBER
TYPE
MATL
SIZE
THICK
FINISH
I HARDWARE
FRAME MATL
FRAME FINISH
JAMB
HEAD
REMARKS
DOI
A
SC-WD
3'-0"x7'-0"
1-3/4"
PAINT
1,2,3,5,
H METAL
PAINT
2 A2-1
1/A2-1
45 MIN:
D02
A
SC-WD
3'-O"x7'-O"
1-3/4"
PAINT
1,3,5,6;
H METAL
PAINT
2/A2-1
t A2-1
D03
A
SC-WD
3'-0"x7' O"
1-3/4"
PAINT
1,2,3,5,
H METAL
PAINT
2/A2-1
1/A2-1
D04
-
SC-WD
3'-0"x7'-O"
1-3/4"
PAINT
1,4,5,E
H METAL
PAINT
-
-
SELF CLOSER
D05
-
SC-WD
3'-0"x7'-O"
1 -3/4"
PAINT
F4 5,6
H METAL
PAINT
-
-
SELF CLOSER
D06
-
SC-WD
3'-0"x7'-O"
1-3/4"
PAINT
1,4,5,E
H METAL
PAINT
-
-
SELF CLOSER
D06
-
SC-WD
3'-0"x7'-O"
1-3/4"
PAINT
1,4,5,6 -
H METAL
PAINT
-
-
SELF CLOSER
D07
A
SC-WD
3'-0"x7'-O"
1-3/4"
PAINT
1 1,2,3;5
1 H METAL
PAINT
2/A2-1
1/A2-1
D08
I A
SC-WD
3'-0"x7'-O"
1-3/4"
PAINT
1,2,3,5,
H METAL
PAINT
2/A2-1
1/A2-1
EX
EXISTING
Name:
Number Floor
I
FINISH SCHEDULE
Base Ceilin Height North t Eas South
West
Remark
G
04
CA
VY
AT
10,-0',
VW
VW
VW
VW
ING
08B
CA
VY
AT
10'-0"
GW
GW
GW
GW --
GW --
INTAKE
03
CA
VY
AT
1,0'-0"
GW
GW
GW
O
09
VCT
VY
AT
1'O'-0"
GW
GW
GW
GW
SLIP RESIST
[TREATMENT
06
T
T
AT
10'-0"
T
T
T
T
WAINSCOT TO
PATIENT THER
07
CA
VY
AT
10'-0"
GW
GW
GW
GW
E
400
CA
CA
AT
10'-0"
GW
GW'
GW
GW
08A
VCT
VY -
AT
1.0,-0,,
GW
GW
GW
GW
PTION
02
CA
VY
AT
—To'--O"
VW
VW
VW
VW
MENT 1
12
CA
UY
AT_
1'0'-0"
GW
GW
GW
GW
MENT 2
11
CA
VY
AT
10'-0"
GW
GW
GW
GW
/ STORAGE
04
VCT
VY
AT
10'-0"
GW
GW
GW
GW
SLIP RESIST
N
05
T
T
AT
1 10'-0"
1T
T
T
I T
I WAINSCOT TO
won]
Hamm
EQUIPMENT SCHEDULE
Equipment Number:
Furniture Type:
SPECIFICATION
Finish:
Width:
Depth:
Color:
Remarks:
AO1A
THERAPY TABLE
BY
TE
AN
A01B
THERAPY TABLE
BY'TENAN
A01C
THERAPY TABLE
BY',TENANT
A02'
WALL CABINET
PLAS LAM
36"
12"
BY TENANT
BY
TE
ANt
A02
WALL CABINET
PLAS LAM
36"
12"'
BY TENANT
BY
TENANT
A02
WALL CABINET
PLAS LAM
36"
12"'
BY TENANT
BY
TENANT
A03
ICE MACHINE
BY TENANT
BY
TENANT
A04'
H&C PACK RACK-
BY TENANT
BY
TENANT
A04
H&C PACK RACK
BY TENANT
BY
TENANT
A05
U/C REFRIGERATOR
BY TENANT
BY
TENANT
A06
FIRE EXTINGUISHER
2A-10BC
WALL MOUNT
BY
TENANT
A07
WSHER/ DRYER
STACKABLE
BY
TENANT
A08
PORTABLE HYDRO T
BY
TENANT
DWARE LEGEND
" PR. 55. HINGES
OP
CK5ET THESE PLANS AND ALL PROPOSED WORK
RIVACY LOCKSET ARE SUBJECTTOANY CORRECTIONS
lo5>=R REQUIRED BYflELDINSPECTORSTHAT
ILENCERS MAY BE NECESSARY IN ORDER TO
L: REDUCED STRIP
RESHOLD. COMPLY WITH ALL APPLICABLE CODI;
ATHER STRIP
FNOTES:
ES:L LOCK SETS t0 BE SCHLAGE OR EQUAL, LEVER TYPE WITH STAIN CHROME FINIS
L HARDWARE TO SE MEDIUM COM17 ERGIAL QUALITY
AX 1/2" HIGH THRESHOLD OR STEP AT EXTERIOR DOORS
ER A.D.A.
OCCUPANCY:
B MEDICAL OFFICES
LIFE SAFETY:
A 2 EXITS REQUIRED
2 EXITS PROVIDED
al
LEGEND ROOM NAME
OFFICE
ROOM NUM R
FLOOR MATERIAL FINISH
BASE MATERIAL FINISH
CEILING MATERIAL
BED
WALL FINISHES
BY ORIENTATION
CEILING HEIGHT
T CERAMIC TILE
CA CARPET
M MARBLE ON THIN SET
AT 2'X4' ACOUSTICAL CEILING TILE F155URED
GW GYPSUM WALLBOARD PAINTED W/ LATEX PAINT
EGGSHEL FINISH OR FLAT
VY= 4' VINYL BASE
XY GYPSUM WALLBOARD PAINTED W/ EPDXY PAINT'
IIIIIIIIIIIIHOR
400
CA
cw
GW
cw
CA
AT
10'-0"
FINISH NOTES
I. CADET TO BE GLUE DOWN, MEDIUM COMMERCIAL GRADE
2. CEILING TILE TO BE FISSURED WHITE AS MANUFACTURER BY ARMSTRONG
3. ALL FINISHES TO HAVE MINIMUM CLASS 'C' FLAME SPREAD RATING
4. ALL FINI5HE5 COLORS, ETC. AS SELECTED BY TENANT
5. VCT TO BE 12'xl2'xl/8' AS MANUFACTURER BY ARMSTRONG OR EQUAL.
6. CAULK PERIMETER OP ALL DOOR t WINDOW FRAME5 AND GAPS
AT DISSIMILAR MATERIALS.
"MMEA
mmummm
FRAMING NOTES
1. ALL H.C. TOILET DIMENSIONS ARE CLEAR DIMENS40N -TO F1NI
FRAMING CONTRACTOR TO VERIFY THAT ALL DIMS LY D3OCS.
WHEN ROOM DIMS ARE FINISHED NOT IN THE ROUGH,
2- HALLWAYS (IF ANY) TO BY A MIN. CLEAR DIMENSk7N 4"
FINISP TO FINISH, NOT ROUGH
3. DOOR JAMB RETURN DIMEN510N5 ARE REQUIRED TRO 14OUt E D S
FOR ACTUAL DIMS. (DO NOT GUESS) CALL ARCHITECT IF A Y QV NS
F Y!
{
;� cY
Z »
I� 2:T
rB�N fk'
'yf�ti �a
28
f YU"
y
r�I
E�
� k
rt
F+P,:xm
�±anc
6ik.3�8d
q �
f�aucG �'
e
Vir-VISIONS
A\
JL
MAwN JL
CrEMM
JL
DATE 9-9-99
PROJECT NO.
130099
-f NO.
A2-1
NEW 2X4 FLUORESCENT
W/ tRISMAtIG LENS
NEW 2X4 FLUORESCENT
W/ EMERGENCY LlksNT
NEW 2X4 FLUORESCENT
W/ PARABOLIC LENSE
NEUJ 2x2 FLUORESCENT
NEW A/C D IF47U6EF,.
EXISTING RETURN AIR
DUCTED
TO REMAIN AS IS
EXISTING A/C DIMU6ER TO REMAIN
AS IS
"P NEW HI -HAT
®
EXIT LIG4.1T5
k:
NEW EMERGENCY /EXIT LIGWTS
O
EXISTING WI-WAT
FIRE SPRINKLER (EXISTING)
"-'U EXISTING EXWAUST FANS
FFL T ® CEUNG L AN
SCALE 1/4"=14-0"
F"„EVI910N9
r.
JL
-------------
g' DmwN JL
JL
rm 1_2-00
No.
130099
ol
4 HYDRO ROOM CABINET
SCAL1 1/2"=1,-O„
SCALE 1/2"=1'-O"
E
EXISTING ACOUSTICAL CEILING —
YINYL WALL PAPER
STYLE 'tlz
NEW SOFFIT
BOTTOM ELEV +$'-0'
VINYL WALL PAPER
STYLE "I z
WALL PAPER
OPENING JAMBS, PROVIDE
9
PLAS LAM. Old 3/4' PLYWD CORNER PROTECTORS
AT ALL EXPOSED SURFACES BOTH 5IDE8 �
Q
1'Fi' EDGE
PLAS LAM FINISH
TYP.
FULL SPLASH
- VINYL WALLPAPER
STYLE "2
3/4'x4' PLYWD. LEDGER
PLAS LAM FINISH
1/2' GYP. WALL
ON 4' METAL STUDS PLAS LAM. ON S/4' PLYWD `
AT 16' C.C. 2S GA MIN TAPERED LEGS
�+
VINYL BASE FILE CABINET BEYOND
�xDJ. ELV�S
e
m
® THERAPY TABLE
a BY TENANT
i
EXISTING ACOUSTICAL CEILING
LINE OF NEW SOFFIT BEYOND I/2' G7P. WALLBRD
BOTTa'1 ELEV +$'-0' ON 4' METAL STUD$
AT 16' OG. 28 GA MIN
WALL PAPER
LAS LAM. ON 3/4' PLYWO
WINDOW JAMBS,
`/ ALL EXPOSED SURFACES
CORNER PROTEG
BOTH SIDES
a' EDGE
PLAS LAM FINISH
5
TYP.
FULLH
FULL SPLASH
FULL SPLASH
VINYL WALLPAPER
�— STYLE 02
m
14' GYP. WALLBRD
N
"'
AT 4'METAL STUDS
C 28 GA MIN
CABINET
ILE CABNET
®
VINYL SASE
SCALE 1/2"=,'-O"
ADJUSTABLE 844ELVE
BRACKETS TYP —
3/4' PLYWOOD W/
PLAS LAM FINISH
CABINET INTERIOR
TO BE MELAMINE FINISH
ALL EDGES, AND SHELVES
4' BACK PLAS LAM CCUN COUNTER —
314, PLYWOOD W/
PLAS LAM FINISH _
PLYWOOD DRAWER
W/ PLAS LAM EMERIOR
FINISH ON EX
POSED
3/4' PLYWOOD W/ —
PLAS LAM FINISH
CABINET INTERIOR
TO BE MELAMNE FINISH
ALL EDGES, AND SHELVES
DRAIIGR
SHELF IR II O
TREATMENT OEM CABINET 11 SE C TI i '.
SCALE 1/2"=1'-O" A3.1 SCALE 1/2"=1'-O"
e■■■■
■■■■■■■■■■■■■■■■■■I
■■
■■■■■■
■■
■■
■■
■■■■■I■■■ii■■ei�■si
I�
■■■iii�==�
iiii■■■■■■■■■
■■�■■■■■�■�
Iol ■\�
■■
■■■■■
SCALE
.F
s
SCALE 1/2"=,'-O"
— PLAS LAM ON 3/4' PLYWD PLAS LAM FNISI4 '
3/41x4' PLYWD. LEDGER
RECEPTION ELEVATION
SCALE 1/'"=V-O"
�
.'-A,
a 0
Lr =AINT
SHELF
/
3/4"RLY
dam' W/
—
o
SHELF
.9
PENCIL
DRALLER
KNEE SPACE
"m
KNEE SPACE
L- FILE `— FILE
CABINET CABINET
g CHARTIKV A
SCALE
9
;a
RE �( V �K N ELEVATION
cv
6f
J
2
',WORAEN BATH t r
a
r
x
SCALE 1/2"=1 -O"
SCAT. E 1/2"=1'-O„
J
PAINT
3/4"
PLA3
PLYWOOD W/
LAM FINISH
/
\
/
/
\
\
.
—�7 i�
\.
7�
\ of
ii
SHELF
4" BACK SPLASH
PLAS LAM COUNTER
DRAWER
REF.
BY OTHERS
INK
—
N
/4" PLYWOOD W/
PLAS LAM FINISH
—
COORDINATE REFRIG
UE W/ MANUF
SPECS
�_Ce__A TING/ PREP ARE,A
SCALE 1 2 =, -O
t�:
A\
I JL
:,r3 mm JL
cif-clKw
lmmgmml�
JL
C'ROXE-CT NO.
13099
:MEET NO.
A3-1
9"-0 �1
A.F.F.
l�F(\hYl I VPMVL
uA MEN BATHROOM L. A I ' 1S MEN F „ATHROOM ELEVATION
/2"_T-0.. vc SCALE 1/2"_1'-O"
V-03 /kk
A.F.F.
BATHROOM I
BATHROOM ELEVATION
SCALE 1/2"=1'-O"
4x
F GRAB BAR
'GRAB BAR
=R
IGn%�^93E29C3h9".�
L
JL
men JL
JL
I-9-0m
FPMFKOXJE-CTT
ab
17) BA-r WINDOW lLG I>?
ISA cl.w, FAIL I-W
i VY'a LQVG LAG COLYB
INTO wrap. ELMCIH'i _._ v
+33' AFF
]N6 CONLUp. i'..
RNER
V/' GYP WKLOIm RI -.�/
]ad LLb.6TLb0 AT 4' GG
",'• "^'BUM WALLFRD
)EB OF WALL
TAL 6TIlD8
TO WALL EDGE
OVER PUNISH
TO MATCH EXIST
-INISH AND COLOR
DILL
WINDOW MULL
SCALE 3'-7'-O"
0
MTL STUD DRAFTSTOP
® CEILING HT-
Q
Q
@
U
N
A.' 25 GA. MTL. RUNNER
TIE WIRE TO STRUCTURE
ABOVE BY S.C.
SUSPENDED ACOUSTICAL LAY -IN
CLG.
R-11 INSULATION
5/8" GYP. WALL BOARD EA. SIDE
3-5/8" 25 GA. MTL. STUDS a 1611 O.C_
(PROVIDE 20 GA STUDS AT ANY
PLUMBING HANGINUG FIXTURE LOCATION
AND HANGING CABINETS)
PROVIDE WOOD BLOCKING FOR
ALL WALL MTO CABINETS AND
SHELVES, ETC,
MTL GHANNEL SECURED WITH
POWDER ACTUATED FASTENER
® 24' O.C.
-VINYL BASE
FINISHED FLOOR
a
MTL STUD DRAFTSTOP
® CEILING HT:
- 3%, 25 GA. MTL. RUNNER
TIE WIRE TO STRUCTURE
ABOVE BY Ca.C.
SUSPENDED ACOUSTICAL LAY -IN
CLG.
�5/6" GYP. WALL BOARD EA. SIDE
z 3-5/8" 25 GA- MTL. STUDS 0 Ill O.C.
(PROVIDE 20 GA STUDS AT ANY
1L PLUMBING HANGINUG FIXTURE LOCATION
AND HANGING CABINETS)
PROVIDE WOOD BLOCKING FOR
U PROVIDE WOOD BLOCKING FOR
H ALL WALL MTD CABINETS AND
(K SHELVES, ETC.
W I
N
MTL- CHANNEL SECURED WITH
POWER ACTUATED FASTENER
m 24' O.C.
VINYL BASE
FINISHED FLOOR
0
SCALE I 1 H.C. I „ T -mo,Rmoa I P INSULATED PARTTPNON-RATED I
� O
O®� CLASSIFIED SYSTEM NO. WL2003
1 HR AND 2HR FIRE RATED PENETRATION
ONE NON-METAL PIPE THRUOGH GYPSUM WALLBRD WALLS
OHR PIRATED GYP RD ASSEMBLY
OONE NON-METALIO PIPE OR CONDUIT TO BE CENTERED
WINN OPENING
THE ANNULAR SPACE BEIWEEN PIPE OR CONDUIT
AND PERIPHERY OF OPENING SHALL HE MIN 1/4' MIN
AND MAX 3/S' PIPE TO RIGIDLY SUPPORTED
ON BOTH AIDES OF CSWI ASSEMBLY.
OPVC NOM 2' Did OR OndLLER SCHEDULE 40 CORE PVC
PIPE FOR WE IN al (PRECCE80 OR SUPPLY)
OI[ VENTED (DRAM W IBT OR vENT>PIPING 5Y6TEM
r
O VENTED
`VALIC NJ'Ipp�M 4' DI4 OR 9MALLEft
(SCHEDULE 40 ORE NECPYC CONDUIT METALLED M ACCORDANCE WITH
ARTICLE 947 CF THE NCODE AND NFPA NO.'10
Be
OCPVC PIPE NOM 2' DOA OR SFMAPER SORT CPVC PIPE FOR USE IN CLOSED
PROCESS OR SUPPLY) OR VENTED (DRAIN WAIST OR VENT)
PIPMG 8Y8TEM3
3� FIRE STOP SYSTEM
INSTALLED $YMETRICAI-LY ON BOTH BIDER
OF WALL ASSEMBLY . THEMI HOURLY F AND T RATINGS FOR THE PIKE STOP SYSTEMS
2 a„A ARE Ea TO THE HOUiY RATING OF THE WALL ASSEMBLY IN WHICJH IS INSTALLED
THE DETAILS FOR THE FI STOP ARE AS FOLLOWS:
Od FILL VOID OR CAYITY MATERIALS- WRAP STRIP- NOM I/4' THICK
IN MECENT ELASTOMERIC Tell F4CED ON ONE SIDE WITH ALWMINUM
3B' 1A FOIL, SUPPLIED IN 2'. WIDE STRIPS NOM. 2' WIDE STRIP TIGHTLY WRAPPED
J AROUND NONMETALIG PIPE(FOIL SIDE WT) WITH SEAM BUTTED. WRAP STRIP
LAYER EECURLY WITH STEEL WIRE OR ALNIINUM FOIL TAPE SLID
INTO ANNULAR SPACE APROX 1-1/4' SUCH THAT APROX S/4' IN, OF THE
WRAP STRIP PRO EB.iROM THE WALL EWEdCE.
MN8'SOTAM '4 CO. witeP
IU VOID OR OH THICINESS OF CAULK YORMAFLTTY APPLIED NTO ANNULAR SPACE BETWEEN WRAP
STRIP AND PERIPHERY OF OPENING. A NOM 1/4' CIA BEAD OF CAULK OR
PUTTY TO BE APPLIED TO THE WRAP 8TRIP /WALL INTERFACE AND TO THE
EXPOSED EDGE OP THE WRAP STRIP LAYERS APROX W4' NCTPROM THE WALL & ACE
rl M IOTA MMNS d MIR 00. CP MOP CALK ORMM-:HINT
MOT& L RATINGS APPLY Cl "M O 21141! ELK R Will
OFOIL TAPE -MOT W iIW- NOT. 4' WIDE, 3 MIL THICK ALUM TAPE
C WRAPPED� WRAP, FLUSH WITH BOTH SIDES OF THE I(ITEIM 3A).
WAl AND PROCEEDING
C
OUTWARD. TAPE B NOT REQUIRED FOR PIPES SHOWN IN REM5 24yB AND 20
®� CLASSIFIED SYSTEM NO. WL2063
2HR FIRE RATED PENETRATION
\\1) PLASTIC PIPE THRUOGH CONCRETEFLOOR OR WALLS
OPRERATED GYP WALLBRD ASSEMBLY
2 O PASTIC PIPE UP TO 4' CIA
SO4 40 P.V.C. PIPE FOR USE
M CLOSED OR OPEN PLUMBING
SYSTEFIB, A MAX ANULAR SPACE 5/8' IS REQUIRED
5 5 3 4 5 O
3 WRAPPED S Y6- IND OUTER
WRAP STRIPE, CONTINUOUSLY
WRAPPED APo30UND OUTER CINCUNFEf�NCE
� PIPE IN TO STACKS CF I] WRAPS
OTREMSTOP- Ml PREFABRICATED STEEL COLLAR .
WRAPPED OVER STACKED STRIPS
AND MECHAICALLT FASTENED TO FLOOR
OR WALL ASSEMBLY
2 O TREMBTOP HYRE 616 MIN I/4' SEALANT APPLIED
AT THE INTEWACE OF THE STEEL COLLAR AND CONCRETE SLAB
AD THE INTE PACE OF THE STEEL DOLLAR AND PIPE
O®L CLASSIFIED SYSTEM NO. WL1020
2HR FIRE RATED PENETRATION
METAL PIPE THRUOGH GYPSUM WALLBRD WALLS
OPRERATED GYP WALLBRD ASSEMBLY
OMETdLIC PIPE MAX S PENETRATING ❑EMS
WITHIN OPENING
q A) TETALIO PPE-2' VIA OR SMALLER SCH 5 OR HEAVIER
B) CONDUIT-2" CIA OR SMALLER ELECTRICAL METALIC
TUBMG OR STEEL CONDUIT
CH_5 O
3 MET4LIC SLEVE NO. 30 MEG GALV SHEET 8TSEL FITTED
WillOPO4RE .SLEEVE IS MECHANICALLY
USING CONCRETE ANCHORS
2 O PACKING MATERIAL- MN 4' THICKNESS � CERABLAKE'
® ® ® ® ® MLY -PS OR CERAMIC FIBER INBJLAINSULATIONMIAMIAS0 PCP)
FlRPACKED INTO OPENING AS A PERMANENT
FORK
- A „A O 'TREMSTOP PIPE SIL MIN 1i SEALANT AAPLIED
®
. 7 WTHI a OPENING, FLW°H WITH BOTH SIDES
OF WALL ASSEMBLY. ADDITIONAL MATERIAL
TO: BE INSTALLED SUCH AS THAT A MIN, V4' CROWN B FORMED
® ® �„ ARROUND PENETRATING ITEM
ri2 I
3.
FIRS: RAT
EXTEND BRACING INTO - 1
ADJACENT STRUCTURAL MEMBER
O
5/8" GYP WALLBRD
ON 25 GA. MTL STUDS
AT 16" G.C.
ANCHOR STUDS W/ TEK SCREWS
MIN. 2 AT EACH CONNECTION —
24"
-.... _.-..,-.._.._-.__._._--- _.__------------ —_
4` 6f (3,FJ�: IJI "I III_�l II,� R 5N""16, II uI ,..-
N
i. HT:
-0]
EXISTING ACOUSTICAL TILE
50TT OF SOFFIT
N.T.S.
nN r
tiara,
3fi
au
F'
e
t>'
.>
3 '
Damn
/
�W
LID
I
'
�aa.TWsa �^
a.
FC3aP �
t'
C
€si�NR
"
JL
DRAWN JL
CHECKED
JL
ATE
i-9-00
y PROJECT NO.
°730099
Oil
1
SHEET NO.
,. 4-1
FIRE PROTECTION SYSTEM
1. EXISTING FIRE SPRINKLER SYSTEM SHALL BE revised and
adjusted to Provide a fully automatic wet pipe sprinkler
system, providing 100% coverage of all areas. System
shall match existing. System shall be designed and installed
as per latest NFPA 13 manual.
2. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY to obtain
approval of sprinkler shop drawings from building's
insurance carrier, the fire marsholl, and all local
authorities having jurisdiction, It shall be the
contractor's responsibility to verify sufficient water
flow and pressure available to the system.
3. CONTRACTOR SHALL VISIT job site prior to bidding.
4. SPRINKLER HEADS (U.L. LISTED): TO MATCH EXISTING.
5. ADJUST ALL EXISTING SPRINKLER HEAD DROPS as required for
new heads and to integrate with new suspended ceiling.
I
,D.
*ARMOVER (BEATER THAN 24" IN
LLENNG GERHALL BE SUPPORTED BY
ARMOVER DETAIL
N.T.S.
a
J
W
N
0
0
O
N
a)
m
0
v
U
a
a)
b
m
3
m
3
6
w
(D
Lf)
�.
z
w
i
:o
0
o
i
0
0
i
3
LEGEND
SYMBOL
•N
�O ER
DESCRIPTION
NEW PENDANT HEAD
RELOCATED HEAD (SEE
RELOCATION DETAIL)
EXISTING UPRIGHT FIRE
itr J SPRINKLER HEAD TO BE
1p REMOVED.
NEW 1" ELBOW
EXISTING 1' NIPPLE
EXISTING BRANCHUNE
CEILING NEW CHROME
FIRE SPRINKLER HEAD.
*ARMOVER GREATER THAN 24" IN
LENGTH SHALL BE SUPPORTED B1
A HANGER.
RELOCATION DETAIL
N.T.S.
F
I
V
O
O
vi
O
•F+
V
�
01
A
CO
V~
i
V
O
LM
r
w
v9
b
d
C
�
N3
IMM
FLOOR PLAN
. PLUMBING
FlAlq==rzllm
RMINATE COND.
WN CONDENSATE
!YVELL
EXISTING
SERVICE
(VERIFY
BEFORE
I
va
W,
0
cp
P,
M2
CIO
IN
ll
(u
k",
W;"*
1p
All
E
mw,m7p �-,WW4%
I
OEI*
RIMS
zm.
FWAg',
RFJ
Sq
M
1300ciGn,'�
m
TO EXISTING
3" VTR
2"
.kl /
3'
/
�1/2"
P-2
F TUB P-3A p'' f 2
3" FD 2« �. L2
P=SH"
zl_� —� /
P--6H
1 1/22'' �` .,� �1 1f2" 3' 3" /
I 2" I I `\ 2" 3" FD _ " .�"
P-5H � 3' 2'
2" / L2" 2"—h P�2H
2" 2" � � �, r 1 7 /2" 3" FD "
`®y 3" 4/
2»
WCO
41 (.)
3'
2« 3"FD r
0000
2
i/2" iRAP
RESEAL (TYP.) 421
2" 20 Pv1
2'
'I,
SANITARY PIPING ISOMETRIC
TIE—IN TO EXISTING ��
1" WATER SERVICE --
1" - -
(21 1/2«
1/2' I
1/2' /' /s - \��\� - 1/2.
> ' ® `I a P-2
1/2° �'- 1 �`-�w1f2. 3/4`\�\
1/2 t 3/4« \T �' 1/2' 1/2'
3 4" H & CW TO •1/2'�//�
1 /2" /2" - -// ` WATER HEATER �� /2"
1
� - //- � (SEE DETAIL) - � (IR � ANGER
HTUB
�1/2' 1 2' r .� rl - 3 1/2° 3/� �1f2" I I t
f4" �•' / \� \�� / I P-2H
�3/4" if2 �O/ -
-
I C P_2 r I P 1
ICE MACHINE t ! t t
\% �I Pe9H
-
\\�\ 1/2«
I I
tl
WATER PIPING ISOMETRIC
FIXTURE CONNECTION SCHEDULE
MARK
DESCRIPTION
WASTE
COLD
WATER
HOT
WATER
REMARKS
P-1H
WATER CLOSET (HANDICAP, TANK)
4
1/2"
--
BRIGGS ALTiMA
P-2H
LAVATORY (HANDICAP, WALL HUNG)
1 1/4
1/2"
1/2"
BRIGGS WHITMAN
FAUCET BL DE HANDLES & GRID DRAIN B & K OR EQUAL
P-3
SINK
2
1/2"
i/2'
COUNTER TOP, S.S
P-4H
ELECT WATER COOLER
1 1/4
1/2
__
BI LEVEL FOR HCP'D EBCO MODEL PBAMSL
W
WASHER
2
1/2"
1/2"
H—TUB
HYDRO TUB
2
1/2'
1/2'
FD
FLOOR DRAIN
3
1/2'
--
1/2' TRAP RESEAL
EWII
ELECTRIC WATER HEATER
--
3/4"
3/4`
40 COON LOW BOY,
, 5KW
60 PER
E 0ENT 2 ELEMENTS
NON89
P-5H
SHOWER (HANDICAPPED)
2"
1/2"
1/2"
WITH ANTI —SCALD PRESS VALVE
P-6H
URINAL (HANDICAPPED)
2'
3/4"
--
BRIGGS
PERFORATED CAP
CLEAN OUT
DRAIN PAN
18" MIN
PITCH DOWN
TOWARD DRAIN
CLEAN OUT
4" MIN
DRAIN LiNE SHALL BE AT LEAST THE
SAME SIZE AS THE NIPPLE ON THE
DRAIN PAN
TYPICAL CONDENSATE DRAIN TRAP
NO SCALE
3/4" HEAT
TRAP
HOT WATER TO
SYSTEM.
P & T RELIEF
VALVE.
ELECTRIC WATER
HEATER
GENERAL:
1. A. ALL WORK SHALL BE DONE in accordance with the South Florida
Building Code (Broward Edition) and with all applicable regulations.
B. DRAWINGS: Refer to all drawings for coordination of the
plumbing work.
C. ARRANGE AND PAY for all permits, licenses, inspections
and tests. Obtain the required certificates and present
to owner.
D. GUARANTEE: The completed installation shall be fully
guaranteed against defective materials and/or improper
workmanship for a minimum of one year for material and
labor.
2. SHOP DRAWINGS: Contractor shall submit for approval, within
30 days of signing contract, a minimum of five copies of fully
descriptive literature, including but not limited to: drain
and plumbing fixtures.
3. PLUMBING FIXTURES: Fixtures shall be as specified and shall be
furnished and installed by this contractor. Fixtures shall be
complete with drains, traps, supplies and any other accessory
required fixtures shall comply with the SFBC water conservation
standards.
4. MATERIALS:
A, PIPING:
a. Soil, waste vent and Condensate Drain: Sanitary pipe,
PVC, DWV, Schedule 40.
b. Domestic water. Copeer pipe, Type L with sweat wrought
copper fittings. Type M" in concealed spaces Is
acceptable. Isolate piping from concrete with
insulating material.
c. Domestic water supply assembly: Chrome finish tubing
with angle off valves.
d, Condensing drain : pvc,dwv pipe and fittings
B. INSULATION:
a. Condensate drain: 3/4 in. thick, foam plastic
insulation, fire resistant type.
5. ALL AUTOMATIC ELECTRIC water heaters shall meet the local
energy conservation standards.
6. PIPING TEST AND DISINFECTiONS:
A Test: All sanitary and domestic water supply piping shall
be tested for leaks before piping is concealed or connected
to equipment and plumbing fixtures.
7. VALVES: Domestic water valves shall be of bronze body,
sweat ends.
9. ALL OUTDOORS FLOOR clean outs shall be terminated up to grade
and shall be marked.
10. CONTRACTOR SHALL COORDINATE exact location of sanitary, and
domestic water piping before starting any work. Notify
Architect/Engineer of any deviations from design drawings.
11. DRAINS:
Floor Drain: FD Josam 30003-5s-50
12. CLEANOUTS:
A. Wall: Josam 58890-15
B. Finished Floor Josam 56020-88-15
13. CONTRACTOR to fire protect and seal all openings and pipe
penetrations thru fire rated walls and ceiling. Materials and
methods to fire rating shall be approved by local authorities.
14. PROVIDE CEILING/WALL ACCESS DOORS where indicated on drawings
and when required to access mechanical equipment. Doors shall
be recessed type, fire rated if in fire rated wall or ceilings.
As Inanufactured by Karp model ROW and KATR.
15. PLUMBING CONTRACTOR SHALL saw cut or core drill existing slabs to
Install new plumbing work. Patch slab to match existing.
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODED,
COLD WATER SUPPLY
—SHUT—OFF VALVE
—HEAT TRAP
—WATER SUPPLY
TO HEATER.
P & T RELIEF LINE
FULL SIZE
TO OUTSIDE, TERMINATE
POINTING DOWN 6"
ABOVE GRADE.
K1\PLDETAIL\EVHC3M
ROOFTOP A/C UNIT SCHEDULE
UNIT DESIGNATION
RTU-1
RTU-2
AREA SERVED
SEE PLANS
SEE PLANS
LOCATION
ROOF
ROOF
UNIT SEER
10.0
90
UNIT TYPE
R00
DOMFLOW
ROOFTOP
REFRIGERANT TYPE
R-22
R-22
ELECTRICAL SERVICE AVAILABLE
208/3/60
208/3/60
TOTAL AIR, CFM
2000
2400
o
OUTSIDE AIR, CFM
250
250
EXTERNAL STATIC PRESSURE. IN. OF WATER
--
--
z
FAN SPEED RPM
--
—
if
BHP (MAX.) / FLA.
1.5/5.9
2.0 / 5.8
ENTERING AIR TEMP., F DB/WB
80/67
--
LEAVING AIR TEMP., F DB/WB
--
--
o
FACE VELOCITY, FPM (MAX.)
--
--
TOTAL CAPACITY, MBH
60.8
78.2
w
SENSIBLE CAPACITY, MBH
45.3
57.6
TYPE AND THICKNESS
1" TA.
i" T.A.
J
FACE AREA, SQ. FT. (MIN)
--
NO. OF COMPRESSORS
1
1
CAPACITY REDUCTION. PERCENT EA.
100%
100%
o
COMPRESSOR RPM. (MAX.)
MOTOR POWER UNIT, KW (MAX.)
--
--
TOTAL FULL LOAD/LOCKED MOTOR AMPS
i7.5/110.0
20.9/142.0
TYPE OF FAN & NO.
PROPELLER - i
ROPEUIER-1
AMBIENT AIR TEMP., F
95
95
FAN MOTOR HP. EACH
1/4
1/4
MAX. CONDENSING TEMP., F
--
--
TYPE
ELECTRIC STRIP
ELECTRIC STRIP
HEATING CAPACITY. BTUH
--
--
=
NO. OF STAGES & KW/STAGE
1 — 7_.9
—
1-7.9
PREFAB ROOF CURB 14" HIGH
NO
NO
SEACOAST CONSTRUCTION
YES
YES
SURE TRIP, HOT GAS REHEAT
--
--
ViBRATOR ISOLATOR TYPE
INTERNAL
INTERNAL
MIN. STATIC DEFLECTION, IN.
--
--
OPERATiNG WEIGHT, LBS.
395
470
DESIGN MANUFACTURER
CARRIER
CARRIER
MODEL NO.
50TJ006-5
507JO07-5
MCA/MOCP
39sy
36.1/45
REFRIG. CHARGE
--
—
GENERAL NOTES-IIVAC
1. GENERAL
A. ALL WORK SHALL be done in accordance With the standard Budding
Code and with all applicable regulations.
B. DRAWINGS: Refer to all drawings for coordination of the HVAC work.
C. ARRANGE AND PAY for all permits, license& inspections and tests.
Obtain the required certificates and present to owner.
D. GUARANTEE: The completed installation shall be fully guaranteed
against defective materials and/or improper workmanship for a
minimum of one year for material and labor. Compressors shah
be guaranteed for a period of five years.
2. SHOP DRAWINGS: Contractors shall submit for approval, within 30 days
after signing contract, a minimum of five copies of fully descriptive
literature, including but not limited to: air outlets.
3. DESIGN PARAMETERS:
A Outdoor design temperature (Summer): 91 F DB ind 79 F WB
B. Outdoor design temperature (Writer)., 45 F
C. Indoor design temperature (Summer): 78 F DB
D. Indoor design temperature (Mnter): 72 F DB
4. ALL THERMOSTATS SHALL have heating mode maximum setting of 75 F, and
tooting mode minimum setting of 70 F. The thermostat shall be arranged
to prevent the simultaneous operation of heating and cooling.
5. ELECTRICAL CONTROLS and power wiring: Under electrical contract.
6. EQUIPMENT SPECIFIED BY manufacturers number shall include all
accessories, controls, etc., listed in the catalog as standard with the
equipment. Optional or additional accessories shall be furnished as
specified.
7. MATERIALS:
A. DUCTWORK:
a. All supply air ductwork shall be 1 1/2" Inch thick fiberglass
ductboard, fabricated and installed as per latest edition
of SMACNA "fibrous Glass Duct Manual. R-6.0 min.
b. All toilet exhaust ductwork shall be galvanized sheet metal
or aluminum duct not lighter than 26 gage.
c. All duct dimensions are clear inside dimensions.
d. Flexible insulated ductwork with 1 1/2" thick fiberglass insulation
with FRK vapor barrier, class I air duct, U.L. listed. R-6.0 min.
e. Dryer ductwork: 26 ga. min. galvanized steel, having a
smooth interior surface with pints running In the direction
of airflow and without sheet metal screws or other fasteners
in the air stream. Maximun length shall not exceed 25 feet.
wall caps shall be provided with backdraft damper.
8. PROVIDE: metal round fittings with damper operator at all flexible duct
connection to supply duct.
9. TEST & BALANCE Contractor shall test & balance all ventilation & air
conditioning systems of Test & Balance report to owner for approval.
10. CONTROLS. Air Conditioning System shall be started & stopped thru individual
thermostat. Individual thermostat shall start/stop supply fan & activate
cooling/heating system as selected. A activation of unit duct smoke
detectector shall sound alarm bell, and indicating light, and shall stop
fan coil unit.
AIR DISTRIBUTION SCHEDULE
DESIGN MANUFACTURER
SIMBOL USE
TYPE ACCESORIES
& & MODEL Mo.
TTT(A ®—SUPPLY AIR
LOUVERED FACE OED —w PRICE AMDA
DIFFUSERS MODULE 24X24
LOUVERED CEILING -- PRICE 70
V RETURN AIR
FLASHING & COUNTERFLASHING
O/A INTAKE W/ VOLUME DAMPER
& BIRD SCREEN
R TU
— SECURE UNIT TO ROOF CURB
WITH 3/8"0 BOLTS 6' O.C.
(MIN. TWO PER SIDE)
UNIT MOUNTED ON
PRE —FABRICATED ROOF CURB
UNIT CURB MOUNTED Ott TOP CHORD
OF STEEL JOIST. W 3/8 is BOLTS TO
SUPPORT 0 EVERY 6-0 O.C.
(MIN. TWO PER SIDE)
ROOF INSULATION
t METAL 'DECK —�
fillLI I I STEEL JOIST —
SUPPLY DUCT
(RETURN DUCT BEHIND) SMOKE DETECTOR SUSPENDED CEILING
(WHERE SPECIFIED)
TYPICAL A/C MOUNTING DETAIL
NO SCALE
VENTII
UNIT DESIGN
AREA SERVE
OPERATING V
LOCATION
FAN TYPE
zQ
4
TOTAL AIR, t
DRIVE TYPE
FAN WHEEL
FAN TIP SPE
FAN SPEED,
TOTAL STATK
FAN MOTOR
FAN MOTOR
STARTER FUF
ELECTRICAL !
f
MASONARY 0
Q
DESIGN MANI
MODEL NUMI
K{
SERVICE SW
SMOKE DEfE
FIRE DAMPS
CONSTRUCTK
MULTIBLADE
BiRDSCREEN
SOLID STATE
THERMOSTAT
FACTORY FAE
FILTER AND f
AIR DUCT (SEE PLAN VIEW)
LOW FRICTION LOSS
BRANCH TAKE —OFF FITTING
METAL ROUND FITTING
QUADRANT OPERATOR TO BE
OUTSIDE INSULATION
PROVIDE INSULATION GUARD
WHERE NECESSARY
- SEAL JOINT 'W/
DUCT SEALER AND
TAPE q-
FLOW
.R WITH OPPOSED
DAMPER
R ROUND TO SQUARE
AIR FLOW
INSULATED FLEX. DUCT
SEAL JOINT WITH DUCT
SEALER AND TAPE
INSULATE DIFFUSER TOPS,
FLEXIBLE DUCT CONNECTION DETAIL
N.T.S.
WALL CAP W/ DAMPER
IN
-- - SCALE 1/400-18-099
OUTDOOR AIR CALCULATIONS AS PER ASHRAE 62-89 ®�
AREA
FLOOR
PERSONS
TOTAL
CFM
CFM
CFM
CFM
SYSTEM
DESIGNATION
AREA. SF M
1000 SF
PERSONS
ERSONS
FT 2
REQUIRED
PROVIDED
DESIGNATION H
THERAPY
1198
20
24
15
--
360
OFFICES
955
7
7
20
--
�140
TOTAL
500
500
RTU-172
(') NET OCCUPIABLE AREA
THESE PLANS AND ALL PROPOSED WO
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THA`
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODF'
tJCIA
C
0
0
Y
r
,gym p
w
QO
TM
,: !D
sffl C4
i
texas: $f
i a„•
Mil
_: _0 /i ri s;
u
m
EXTEND EXISTING
Z C. (VERIFY LOCATI
NEW 4#3/0 THHN CU NEW 4#3/0 THHN CU
& 1#6 CU (GR) IN EXISTING & 1# CU (GR) IN NI
— 2 C. 2° C.
J
----------
I 14
EXISTING 4-3/0 THHN CU
IN 2° C.
I
I —EXISTING FPL
METER CAN
I (PROVIDE
�r _1 F_ I NEW METER)
EXISTING I I I
200 A. 3P
SAFETY SWITCH I I I I
W/200 A L J L J
FUSES
rEXISTING 12 X 12 X L — — —
L------ WIREWAY J
I
EXISTING 2 SETS OF 350 MCM CU AND
FPL 0 TH CU CONDUCTORS TO
T TYPE: yp SQUARE Mi LOAD CENTER ,RLTS: 120/208V,30,4Wi
PANEL
LOAD:»
ofts R
®mmv mom
�„
■�1■��
Its
In
M■MEIMM
-I/
WIMIRMATA
ME1110110001MMIN
M
MMWA
In
-----
0
o 00'i
WASHER
® THRU TIME CLOCK
HEATING LOAD LARGER, COOLING LOAD NON —CONCURRENT.
CONNECTED LOAD: 53990 VA
25% OF LIGHTING LOAD: 1500 VA
25% OF LARGER MOTOR: 2492 VA
57982 VA
THESE PLANS AND ALL PROPOSED WORK
x C) Fd ; PLAN —POWER ARE SIMCT TO ANY CORRECTIONS
REQUIRED BY FIELD WPECTORS THAT
--------- _^- -�- a — SCALE 1/4"21'-0" MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODFA
�i
19
Kwl_ _'0T Irgl`m
e01101a
s
100W X'MER
120V-24V IN
J. BOX A/C UNIT
F
I i
CKT. A/C UNIT
CKT. CONTROL
It
DUCT SMOKE DETECTOR
NOTIFIER CAT # DH400 ACDC SERIESOR EQUAL
�;_2C--REMOTE SOUNDER /LED
ANNUNCIATOR.
NOTIFlER CAT. # APA451
OR EQUAL MTD. ON
WALL ® 7-6" A.F.F. ( MAX ).
REMOTE TEST SWTCH
NOTIFIER CAT. # RTS451 KEY
MTO. ON WALL 0 4'-6" A.F.F. ( MAX }
1— GENERAL CONDITIONS: THE GENERAL CONDITIONS FORM A PART
OF THE SPECIFICATIONS FOR THIS TRADE EACH SUB —CONTRACTOR
MUST READ GENERAL CONDITIONS, AS WELL AS THE SPECIFICATIONS
FOR WORK OF OTHER TRADES AND TO ASCERTAIN WHAT WORK AND
MATERIALS HE MUST APPLY TO THE OTHER CONTRACTORS.
2— SITE INVESTIGATION: IT SHALL BE THE RESPONSABILITY OF BIDDERS
TO VISIT THE SITE AND TO ACQUAINT THEMSELVES WTH AL INFORMATION
REGARDING THE NEW BUILDING.
3— DESIGN: THE INSTALLATION OF THE WRING SYSTEM SHOWN ON
THESE DWGS. SHALL CONFORM TO THE REGULATIONS OF LOCAL CODES
AND ORDINANCES, N.E C. AND LOCAL UTILITY COMPANIES.
4— MINIMUM STANDARDS: THE MATERIAL, INSTALLATIONS AND WORKMANSHIP
FURNISHED UNDER THIS SECTION SHALL CONFORM TO THE REQUIREMENTS
OF LOCAL CODES AND N.E.C., ALL MATERIALS USED SHALL BE USTED
OR BEAR U.L APPROVAL
5— GUARANTEE: THIS SUB —CONTRACTOR SHALL FURNISH A WRITTEN
GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT, SHALL BE
FREE FROM DEFECTS OR WORKMANSHIP AND MATERIALS FOR A PERIOD OF
ONE YEAR, AT CONTRACTOR'S EXPENSE, REPAIR AND REPLACE ALL WORK
WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE.
6— RACEWAYS AND FITTINGS:
a) RIGID GALVANIZED : 1-1/20 OR LARGER , AND IN SLAB ABOVE GRADE
b) PVC : IN OR UNDER GND FLOOR SLAB , OR UNDERGROUND ONLY .
a) EMT, MC OR BX RACEWAYS/SYSTEMS : ALL OTHER LOCATION,
FITTING TO MATCH THE APPROVED
USED RACEWAY.
7— CONDUCTORS: THE MINIMUM CONDUCTOR NO. 12 SOLID CU. TYPE °THW'
INSULATION.
8— ALL EQUIPMENT LISTED ON DWIS. BY CATALOG NO. SHALL BE
LIMITED TO THE KIND AND MANUFACTURE LISTED. NO SUBSTITUTION
SHALL BE ALLOWED UNLESS APPROVED BY THE ENGINEER A WRITTEN
GUARANTEE OF THREE YEARS AND CREDIT FROM BASIC BID SHALL BE
SUBMITTED WTH SHOP DRAWINGS.
9— CONTRACTOR TO INSTALL AND/OR CONNECT ALL EQUIPMENTS
AND CONTROLS SUPPLED BY OWNER, OR ANY OTHER TRADE. SEE
OTHER TRADES DRAWINGS AND SPECIFICATIONS.
10— ALL FEEDERS AND BREAKERS SHALL BE COORDINATED WITH
EQUIPMENT'S PLATE AT SITE.
STORE SIGN J—BOX
(VERIFY LOCATION)
CEILING SHOW WINDOW
OUTLET (TYP)
LIGHT FIXTURE.
SCALE 1/4"=1'-O"
FLUORESCENT LAY —IN
(TURES W/3—T32 BULBS
2GY SAVING BALLAST AND
IC LENS (TYP)
PLANS AND ALL P{q0
McCT TO POSED WORt,
?ED BY A°E t0CT10NS
ENE FIELD Nap
YIN OMER To
TWAT
WITH ALL APPLICAB ODPF
COMBINATION EXIT/ SIGN
EMERGENCY LIGHT W/bATTERY
PACK CONNECTED AHEAD OF
SWITCH (TYPICAL)
:'J � cUS �
�' ;
"
J.
jaime lichi and associates architects, inc. ph.(954)389-9499 fax (954)389-8468
City Of Port St Lucie „ 20D Z. & 41
Building and Zoning Department _
Re:HealthSouth PGA
7-26-2000
Dear sir:
Please note that I have approved WPR Contracting to install a 4" dry4i vent frowhe iriterior of the wash room, to
be surface mounted to finished drywall; to:includai 6"X6" galvanized metal chase, painted white, to extend from
ceiling grid.to 40". off. Said ve4t,extends-froni`c"g grid to vertical portion of mansard room trusses and should
be installed with a waterproof exhaust cap as shown.
WATER PROOF DRYER ?'
CAF'W/ INSECT SCREEN !'
MANSARD ,ROOF
OPEN'VEB JOISV SYSTEM
h'RYER.VENT IN 6°x6' GALV. MTL
ATTACHED TO EXIST DRYWALL
EXIST ACCOUST CLG. ;,r • i J
METAL DRYER VE '
5.'x6' METAL CHASE TO • ... EXTERIOR. WALL
CEILING FROM 40'. A.F.F.
5/8.' GYP WALLBRD
{ •P.T. 3/4' FURRING
4.0' IF.
y DRYER ATTAEHEMENT
12!,
0A.F.
SECTION
_. -P.T, 3/4' FURRING.
•'cr,..- 5/8' GYP WALLBRD .
'x6' METAL CHASE TO
4" METAL RYE.R. VENT CEILING FROM 40' A.F.F.
OW__ E�
Sincerely;'
2`
Jaime Liclu � AUG 1 0 / ,,(({{JJ��
Architect 15482
,unit' Public Wor1<4
R f .7nc,
CONSULTINGENGINEERS
-,L bgpwl'5-
June 22, 2000
St. Lucie County Building Department
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Ann.: Mechanical Department
Re: Health South @ PGA
8565 So. Commerce Center Drive' ,
Port St: Lucie, Florida
Permit No. 20020645
Gentlemen,'
Please be 'sed tM the supply main ducts w sitioned as per attached'sketch to
clear e s fire er lines.
Sin ly
��.
- .;, :. .?,yam � •,
1 ena 7r., PT.
Attachment 4.
RPJ/hp
`42;7' zedo Street • Coral Gables, FL 33146 Phone; (305) 441-1523 • Fax: (305) 567-9476
E-Mail: rpjmep@bellsouth.net
id o- �, A �. 1- 41011< a
.-NU S OA) Lin, 0(-1r
ALL U✓N�t..
jaime lichi and associates architects, inc.
ph.(954)389-9499 fax (954)389-8468
1027 lido court weston, florida 33326
City Of Port St Lucie
7-17-2000
ATTN.: FIELD BUILDING INSPECTOR
RE: HeathSouth PGA
Please note I have approved the use of 3 grab bars at the shower location instead of on
continuous grab bar as per my documents. Also
the nurse call has been deleted at this time.
Thank you f your cooperation.
Si '�
7
fl
_3V. P. R. CONTRACTING, ' 1565 N. PARK DRIVE BUILDING "E" SUITE 103, WESTOTj, FLORIDA 33326
INC.
W o DO a (0
F-) F A
X E
JUL 10 2000 Date:
Number of pages including cover sheet: 21,11'.1
FAX
I g1'
To:
Phone:
Faxphone: 66 I L4 6 2 114
CC:
REMARKS: El Urgent
o,t.ev- flel
From.�
tg,
.,W
Mobile:.
Phone:
954 3&0
re
,Faary nq� `34
7t
H
'YES
,#se 0, ent
M�v
40 0,4,
Al.
a