HomeMy WebLinkAbout16032913 - iko shingles noa
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 1 of 4
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Iko Industries Ltd.
40 Hansen Rd. S.
Brampton, Ontario CANADA
L6W3H4
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Cambridge, Cambridge HD, and Biltmore AR Asphalt Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.14-0603.02 and consists of pages 1 through 4.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 2 of 4
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves a roofing system using Cambridge AR, Cambridge HD, and Biltmore AR asphalt shingles
manufactured by IKO Industries Ltd. as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Specifications
Product Description
Cambridge
Manufacturing Location #1, 2, 3
13 3/4" x 40 7/8" TAS 110 A heavy weight, fiberglass reinforced
laminate asphalt shingle.
Cambridge HD
Manufacturing Location #1, 2, 3
13 3/4" x 40 7/8" TAS 110 A heavy weight, fiberglass reinforced
laminate asphalt shingle.
Biltmore AR
Manufacturing Location #1, 2
13 3/4" x 40 7/8" TAS 110 A heavy weight, fiberglass reinforced
laminate asphalt shingle.
MANUFACTURING LOCATION
1. Kankakee, IL
2. Wilmington, DE
3. Sylacuaga, AL
EVIDENCE SUBMITTED
Test Agency
Test Identifier Test Name/Report Date
PRI Construction Materials Inc. IKO-050-02-01 TAS 100 12/21/09
IKO-076-02-01 TAS 100 02/21/12
IKO-114-02-01 TAS 100 09/25/14
IKO-099-02-01 TAS 100 05/12/14
IKO-096-02-01 ASTM D 3462 09/27/13
IKO-095-02-01 ASTM D 3462 09/27/13
IKO-121-02-01 ASTM D 3462 09/25/14
IKO-100-02-01 ASTM D 3161 (TAS-107) 05/21/14
IKO-115-02-01 ASTM D 3161 (TAS-107) 09/25/14
FM Approvals 3041689 ASTM D 3462 02/23/11
3036971 ASTM D 3161 (TAS-107) 01/04/09
3042673 ASTM E 108 04/12/11
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 3 of 4
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
1. Shingles shall be labeled with the Miami-Dade Seal as seen below, or the wording “Miami-Dade County
Product Control Approved”.
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 4 of 4
DETAIL A
CAMBRIDGE, CAMBRIDGE HD, BILTMORE AR COURSE LAYOUT
SECOND COURSE
THIRD COURSE
FIRST COURSE
EDGE OF ROOF
4"
14"
24"Note: Roofing Cement not shown in this layout.
This drawing is for course layout only. See Detail B
for nailing and cement placement details.
DETAIL B
CAMBRIDGE, CAMBRIDGE HD, BILTMORE AR
END OF THIS ACCEPTANCE
40 7
8"
13 3
4"
6 3
8"5 7
8"
1"1"1"1"
EXPOSURE