HomeMy WebLinkAboutAPPROVED, NOA Boral Galena
NOA No.: 19-0925.03
Expiration Date: 11/18/24
Approval Date: 11/21/19
Page 1 of 6
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Boral Roofing, LLC
7575 Irvine Center Drive Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Galena Spanish “S” Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manu facturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA 19-0220.05 and consists of pages 1 through 6.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 19-0925.03
Expiration Date: 11/18/24
Approval Date: 11/21/19
Page 2 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Galena Spanish “S” Concrete Roof Tile, as manufactured by Boral Roofing,
LLC as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for
High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable
Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using
the values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Dimensions
Test
Specifications
Product
Description
Galena Spanish ‘S’ Roof
Tile
L = 17"
W = 10"
H = 2.7”
Thickness: ½”
TAS 112 High profile, interlocking, one-piece, “S”
shaped, concrete roof tile equipped with
two nail holes. For direct deck, mortar or
adhesive set applications.
Trim Pieces L = varies
W = varies
Varying thickness
TAS 112 Accessory trim, concrete roof pieces for
use at hips, rakes, ridges and valley
terminations. Manufactured for each tile
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee, FL
2.2. EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Redland Technologies 7161-03
Appendix III
Static Uplift Testing
PA 102 & PA 102(A)
Dec. 1991
Redland Technologies 7161-03
Appendix II
Wind Tunnel Testing
PA 108 (Nail-On)
Dec. 1991
Redland Technologies P0647-01 Wind Tunnel Testing
PA 108 (Mortar Set)
Aug. 1994
Redland Technologies P0402 Withdrawal Resistance Testing of
screw vs. smooth shank nails
Sept. 1993
The Center for Applied
Engineering, Inc.
94-084 Static Uplift Testing
PA 101 (Mortar Set)
May 1994
The Center for Applied
Engineering, Inc.
94-083 Static Uplift Testing
PA 101 (Adhesive Set)
April 1994
NOA No.: 19-0925.03
Expiration Date: 11/18/24
Approval Date: 11/21/19
Page 3 of 6
Test Agency Test Identifier Test Name/Report Date
The Center for Applied
Engineering, Inc.
25-7183-4 Static Uplift Testing
PA 102 (2 Quik-Drive Screws, Direct
Deck)
Feb. 1995
The Center for Applied
Engineering, Inc.
25-7214-3 Static Uplift Testing
PA 102 (1 Quik-Drive Screw, Direct
Deck)
March, 1995
Redland Technologies Letter Dated Aug. 1,
1994
Wind Tunnel Testing
PA 108 (Nail-On)
Aug. 1994
The Center for Applied
Engineering, Inc.
Project No. 307025
Test #MDC-78
Wind Driven Rain
PA 100
Oct. 1994
Nutting Engineering 13343.1 Physical Properties
TAS 112
June 2007
Celotex Corporation Testing
Service
520111-3
520191-2-1
Static Uplift Testing
PA 101
Dec. 1998
March 1999
Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999
Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996
Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996
Walker Engineering, Inc. Evaluation Calculations 25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
December 1996
Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995
Walker Engineering, Inc. Evaluation Calculations Restoring Moment Due to Gravity 09/14/09
Walker Engineering, Inc. Calculations Aerodynamic Multiplier 09/14/09
American Test Lab of South
Florida
RT0624.04-14 TAS 112 07/07/14
RT0807.02-18 TAS 112 8/14/18
RT0802.06-19 TAS 112 8/02/19
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Miami-Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 Mechanically attached tiles 4/12 minimum slope.
3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.8 All products listed herein shall have a quality assurance audit in accordance with the F lorida Building
Code and Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 19-0925.03
Expiration Date: 11/18/24
Approval Date: 11/21/19
Page 4 of 6
4. INSTALLATION
4.1 Galena Spanish “S” Concrete Roof Tile and its components shall be installed in strict compliance with
Roofing Application Standard RAS 118, RAS 119 and RAS 120.
4.1 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (l x w )
Tile Profile Weight-W (lbf) Length-l (ft.) Width-w (ft.)
Galena Spanish ‘S’ Roof Tile 8.5 1.42 0.833
Table 2: Aerodynamic Multipliers - (ft3)
Tile
Profile
(ft3)
Direct Deck Application
Galena Spanish ‘S’ Roof Tile 0.235
Table 3: Restoring Moments due to Gravity - Mg (ft.-lbf)
Tile
Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or
greater
Galena
Spanish
‘S’ Roof
Tile
Direct
Deck
Direct
Deck
Direct
Deck
Direct
Deck
Direct
Deck
Direct
Deck
6.20 6.13 6.03 5.89 5.74 5.57
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf)
for Mechanically Attached Systems
Tile
Profile Fastener Type Direct Deck
(min 15/32” plywood)
Direct Deck
(min. 19/32” plywood)
Galena
Spanish ‘S’
Roof Tile
2-10d Ring Shank Nails 28.6 41.2
1-10d Smooth or Screw
Shank Nail 2 5.1 6.8
2-10d Smooth or Screw
Shank Nails 6.9 9.2
1 #8 Screw 2 20.7 20.7
2 #8 Screw 43.2 43.2
1-10d Smooth or Screw
Shank Nail (Field Clip)2 23.1 23.1
1-10d Smooth or Screw
Shank Nail (Eave Clip)2 29.3 29.3
2-10d Smooth or Screw
Shank Nails (Field Clip) 27.6 27.6
2-10d Smooth or Screw
Shank Nails (Eave Clip) 38.1 38.1
2-10d Ring Shank Nails1 33.1 48.1
1 Installation with a 4" tile head lap and fasteners are located a min. of 2 ½” from head of tile. 4/12 slope and above.
2 When using only one fastener use the hole that is approximately 4 ¾” away from interlocking edge.
NOA No.: 19-0925.03
Expiration Date: 11/18/24
Approval Date: 11/21/19
Page 5 of 6
Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile Tile Application Minimum Attachment Resistance
Galena Spanish ‘S’ Roof Tile Adhesive 29.34
3 See manufacturer’s component approval for installation requirements.
4 The Dow Chemical Company Tile Bond Average weight per patty 10.7 grams.
3M™ 2-Component Foam Roof Tile Adhesive AH-160, average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile Tile Application Minimum Attachment
Resistance
Galena Spanish ‘S’ Roof
Tile 3M™ 2-Component Foam Roof Tile Adhesive AH-160 66.5 5
3M™ 2-Component Foam Roof Tile Adhesive AH-160 38.7 6
5 Large paddy placement of 63 grams of 3M™ 2-Component Foam Roof Tile Adhesive AH-160.
6 Medium paddy placement of 27 grams of 3M™ 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf)
for Mortar or Adhesive Set Systems
Tile
Profile Tile Application Minimum Attachment
Resistance
Galena Spanish ‘S’
Roof Tile Mortar Set 24.5
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as s een below or following
statement: "Miami-Dade County Product Control Approved".
GALENA SPANISH “S” CONCRETE ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
NOA No.: 19-0925.03
Expiration Date: 11/18/24
Approval Date: 11/21/19
Page 6 of 6
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
PROFILE DRAWINGS
Boral GALENA SPANISH “S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
10"17"