Loading...
HomeMy WebLinkAboutAPPROVED, NOA Boral Galena NOA No.: 19-0925.03 Expiration Date: 11/18/24 Approval Date: 11/21/19 Page 1 of 6 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing, LLC 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Galena Spanish “S” Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manu facturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA 19-0220.05 and consists of pages 1 through 6. The submitted documentation was reviewed by Freddy Semino NOA No.: 19-0925.03 Expiration Date: 11/18/24 Approval Date: 11/21/19 Page 2 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Galena Spanish “S” Concrete Roof Tile, as manufactured by Boral Roofing, LLC as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Test Specifications Product Description Galena Spanish ‘S’ Roof Tile L = 17" W = 10" H = 2.7” Thickness: ½” TAS 112 High profile, interlocking, one-piece, “S” shaped, concrete roof tile equipped with two nail holes. For direct deck, mortar or adhesive set applications. Trim Pieces L = varies W = varies Varying thickness TAS 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION 1. Okeechobee, FL 2.2. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Appendix III Static Uplift Testing PA 102 & PA 102(A) Dec. 1991 Redland Technologies 7161-03 Appendix II Wind Tunnel Testing PA 108 (Nail-On) Dec. 1991 Redland Technologies P0647-01 Wind Tunnel Testing PA 108 (Mortar Set) Aug. 1994 Redland Technologies P0402 Withdrawal Resistance Testing of screw vs. smooth shank nails Sept. 1993 The Center for Applied Engineering, Inc. 94-084 Static Uplift Testing PA 101 (Mortar Set) May 1994 The Center for Applied Engineering, Inc. 94-083 Static Uplift Testing PA 101 (Adhesive Set) April 1994 NOA No.: 19-0925.03 Expiration Date: 11/18/24 Approval Date: 11/21/19 Page 3 of 6 Test Agency Test Identifier Test Name/Report Date The Center for Applied Engineering, Inc. 25-7183-4 Static Uplift Testing PA 102 (2 Quik-Drive Screws, Direct Deck) Feb. 1995 The Center for Applied Engineering, Inc. 25-7214-3 Static Uplift Testing PA 102 (1 Quik-Drive Screw, Direct Deck) March, 1995 Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing PA 108 (Nail-On) Aug. 1994 The Center for Applied Engineering, Inc. Project No. 307025 Test #MDC-78 Wind Driven Rain PA 100 Oct. 1994 Nutting Engineering 13343.1 Physical Properties TAS 112 June 2007 Celotex Corporation Testing Service 520111-3 520191-2-1 Static Uplift Testing PA 101 Dec. 1998 March 1999 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 December 1996 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Restoring Moment Due to Gravity 09/14/09 Walker Engineering, Inc. Calculations Aerodynamic Multiplier 09/14/09 American Test Lab of South Florida RT0624.04-14 TAS 112 07/07/14 RT0807.02-18 TAS 112 8/14/18 RT0802.06-19 TAS 112 8/02/19 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Miami-Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Mechanically attached tiles 4/12 minimum slope. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.8 All products listed herein shall have a quality assurance audit in accordance with the F lorida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 19-0925.03 Expiration Date: 11/18/24 Approval Date: 11/21/19 Page 4 of 6 4. INSTALLATION 4.1 Galena Spanish “S” Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.1 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (l x w ) Tile Profile Weight-W (lbf) Length-l (ft.) Width-w (ft.) Galena Spanish ‘S’ Roof Tile 8.5 1.42 0.833 Table 2: Aerodynamic Multipliers -  (ft3) Tile Profile  (ft3) Direct Deck Application Galena Spanish ‘S’ Roof Tile 0.235 Table 3: Restoring Moments due to Gravity - Mg (ft.-lbf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Galena Spanish ‘S’ Roof Tile Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck Direct Deck 6.20 6.13 6.03 5.89 5.74 5.57 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf) for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 15/32” plywood) Direct Deck (min. 19/32” plywood) Galena Spanish ‘S’ Roof Tile 2-10d Ring Shank Nails 28.6 41.2 1-10d Smooth or Screw Shank Nail 2 5.1 6.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 1 #8 Screw 2 20.7 20.7 2 #8 Screw 43.2 43.2 1-10d Smooth or Screw Shank Nail (Field Clip)2 23.1 23.1 1-10d Smooth or Screw Shank Nail (Eave Clip)2 29.3 29.3 2-10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 2-10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 2-10d Ring Shank Nails1 33.1 48.1 1 Installation with a 4" tile head lap and fasteners are located a min. of 2 ½” from head of tile. 4/12 slope and above. 2 When using only one fastener use the hole that is approximately 4 ¾” away from interlocking edge. NOA No.: 19-0925.03 Expiration Date: 11/18/24 Approval Date: 11/21/19 Page 5 of 6 Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Galena Spanish ‘S’ Roof Tile Adhesive 29.34 3 See manufacturer’s component approval for installation requirements. 4 The Dow Chemical Company Tile Bond Average weight per patty 10.7 grams. 3M™ 2-Component Foam Roof Tile Adhesive AH-160, average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Galena Spanish ‘S’ Roof Tile 3M™ 2-Component Foam Roof Tile Adhesive AH-160 66.5 5 3M™ 2-Component Foam Roof Tile Adhesive AH-160 38.7 6 5 Large paddy placement of 63 grams of 3M™ 2-Component Foam Roof Tile Adhesive AH-160. 6 Medium paddy placement of 27 grams of 3M™ 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Galena Spanish ‘S’ Roof Tile Mortar Set 24.5 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as s een below or following statement: "Miami-Dade County Product Control Approved". GALENA SPANISH “S” CONCRETE ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE) NOA No.: 19-0925.03 Expiration Date: 11/18/24 Approval Date: 11/21/19 Page 6 of 6 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS Boral GALENA SPANISH “S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE 10"17"