REVISED MANJ
Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Load Short Form Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Information InfiltrationClgHtg Blower doorMethod9041Outside db (°F) 3 (partial) / 1Shielding / stories7570Inside db (°F) 50 Pa / 0 cfmPressure / AVF1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond 14ACXS030-230A** AHRI ref Coil CBA27UHE-030-230*++TDR AHRI ref 10259390 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW6.9 Sensible cooling Btuh20020 Heating output Btuh23547 Latent cooling Btuh8580 Temperature rise °F22 Total cooling Btuh28600 Actual air flow cfm953 Actual air flow cfm953 Air flow factor cfm/Btuh0.043 Air flow factor cfm/Btuh0.047 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Bed 3 174 1789 1091 76 52 Bath 2 54 667 289 28 14 Lin 8 0 0 0 0 Bed 2 159 2754 1832 117 87 Hall 30 0 0 0 0 Laundry 52 150 782 6 37 Kit/Nook 326 2991 5027 127 238 Great Room 408 4676 5548 199 262 M Lin 9 0 0 0 0 M Bath 132 2757 1416 117 67 Wtr Clst 26 645 260 27 12 Closet 21 0 0 0 0 WIC 42 687 260 29 12 Master Suite 337 5294 3648 225 173 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W House d 1777 22410 20151 953 953 Other equip loads 1522 808 Equip. @ 0.95 RSM 19996 Latent cooling 7159 TOTALS 1777 23932 27155 953 953 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 3 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Load Short Form Oct 29, 2019Date:Mini Split Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Information InfiltrationClgHtg Blower doorMethod9041Outside db (°F) 3 (partial) / 1Shielding / stories7570Inside db (°F) 50 Pa / 0 cfmPressure / AVF1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Generic Make Generic Trade Trade Model SEER 18.0, HSPF 9.1 Cond SEER 18.0, HSPF 9.1 AHRI ref Coil AHRI ref Efficiency 9.1 HSPF Efficiency 14.7 EER, 18 SEER Heating input Sensible cooling Btuh4200 Heating output Btuh @ 47°F5970 Latent cooling Btuh1800 Temperature rise °F27 Total cooling Btuh6000 Actual air flow cfm200 Actual air flow cfm200 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.048 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.74 Capacity balance point = 45 °F ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Garage 654 7927 4176 200 200 Mini Split d 654 7927 4176 200 200 Other equip loads 0 0 Equip. @ 0.95 RSM 3984 Latent cooling 1499 TOTALS 654 7927 5483 200 200 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Building Analysis Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) Blower doorMethod)L(15-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 0 cfmPressure / AVF7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 11.828282.1Walls 8.119339.0Glazing 0.3773.7Doors 11.828191.6Ceilings 22.553733.03.0Floors 17.441632.6Infiltration 21.85217Ducts 00Piping 00Humidification 6.41522Ventilation0Adjustments 100.023932Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 11.323691.7Walls 18.1380317.6Glazing 0.4783.7Doors 10.421721.2Ceilings 000Floors 5.912400.8Infiltration 28.05869Ducts 3.9808Ventilation 22.04620Internal gains 00Blower 0Adjustments 100.020960Total Latent Cooling Load = 7159 Btuh Overall U-value = 0.207 Btuh/ft²-°F Data entries checked. 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Building Analysis Oct 29, 2019Date:Mini Split Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) Blower doorMethod)L(15-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 0 cfmPressure / AVF7.515.0Wind speed (mph) Heating Walls Other Doors Ceilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 11.99412.1Walls 1.71368.7Glazing 8.66863.7Doors 13.110381.6Ceilings 29.823663.63.6Floors 21.517022.6Infiltration 13.41059Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.07927Total Cooling Walls Glazing Doors Ceilings Infiltration Ducts % of loadBtuhBtuh/ft²Component 18.97881.7Walls 3.41449.2Glazing 16.66933.7Doors 19.18001.2Ceilings 000Floors 12.15070.8Infiltration 29.81245Ducts 00Ventilation 00Internal gains 00Blower 0Adjustments 100.04176Total Latent Cooling Load = 1499 Btuh Overall U-value = 0.207 Btuh/ft²-°F WARNING: window to floor area ratio = 2.4% - less than 5%. 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Component Constructions Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) Blower doorMethod)L(15-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 0 cfmPressure / AVF7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-9 Ext Bd Ins, 8" Thk, 1/2" DW 0.071396n 6811.728132.0510.0 6161.727362.0510.00.071358e 7071.728432.0510.00.071411s 491.72582.0510.00.07128sw 2691.723212.0510.00.071156w 471.72562.0510.00.07128nw 23691.7228282.0510.00.0711378all Partitions (none) Windows Impact: Impact; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (1 ft window ht, 1 ft sep.); 6.67 ft head ht 186.93197.5400.2603n Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.67 ft head ht 1107.071368.7000.30016n 33521.51368.7000.30016e 49421.52008.7000.30023e 93917.34718.7000.30054all Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (4 ft window ht, 1 ft sep.); 6.67 ft head ht 25821.51048.7000.30012e Impact: Impact; NFRC rated (SHGC=0.20); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (7 ft window ht, 8 ft sep.); 6.67 ft head ht 89021.24029.5700.33042e Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (2 ft window ht, 1 ft sep.); 6.67 ft head ht 369.07358.7000.3004s Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 14.6 ft sep.); 6.67 ft head ht 2299.972008.7000.30023s 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W Impact: Impact; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.67 ft head ht 23315.31368.9900.31015sw 31520.21408.9900.31016w 63020.22808.9900.31031w 25616.01448.9900.31016nw 143318.47018.9900.31078all Doors DftDoor: Fbrgl 783.73773.697.00.12721w Ceilings R-20 Icynene: Attic, Shingle Roof, R-20 Spray Foam, 1/2" DW 21.00.4051777 21721.2228191.59 Floors On Grade, Tile Flr 00537328.700.989187 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 3 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Component Constructions Oct 29, 2019Date:Mini Split Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) Blower doorMethod)L(15-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 0 cfmPressure / AVF7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-9 Ext Bd Ins, 8" Thk, 1/2" DW 0.071150n 2581.723082.0510.0 1381.721642.0510.00.07180e 2621.723132.0510.00.071152s 1311.721562.0510.00.07176w 7881.729412.0510.00.071459all Partitions (none) Windows Impact: Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.67 ft head ht 1449.211368.7000.30016s Doors DftDoor: Fbrgl 673.73663.697.00.12718n 6263.736203.697.00.127168w 6933.736863.697.00.127186all Ceilings R-20 Icynene: Attic, Shingle Roof, R-20 Spray Foam, 1/2" DW 21.00.405654 8001.2210381.59 Floors On Grade, Tile Flr 00236628.700.98983 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Project Summary Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor:0 Slash Pine Trail, Fort Pierce, FL 34951 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh17193 Structure Btuh14282 Ducts Btuh5217 Ducts Btuh5869Central vent (48 cfm) 1522 Btuh Central vent (48 cfm) Btuh808 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh23932 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh19996 Method Latent Cooling Equipment Load SizingBlower door Shielding / stories 3 (partial) / 150 Pa / 0 cfmPressure / AVF Structure Btuh3631 Ducts Btuh1683Central vent (48 cfm) Btuh1846 CoolingHeating Outside air17771777Area (ft²) Equipment latent load Btuh7159 1558515585Volume (ft³)Air changes/hour 0.280.50 Equipment Total Load (Sen+Lat)Btuh27155 Equiv. AVF (cfm) 73131 Req. total capacity at 0.70 SHR ton2.4 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond 14ACXS030-230A**AHRI ref Coil CBA27UHE-030-230*++TDR AHRI ref 10259390Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW6.9 Sensible cooling Btuh20020Heating output Btuh23547 Latent cooling Btuh8580 Temperature rise °F22 Total cooling Btuh28600Actual air flow cfm953 Actual air flow cfm953 Air flow factor cfm/Btuh0.043 Air flow factor cfm/Btuh0.047Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Project Summary Oct 29, 2019Date:Mini Split Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor:0 Slash Pine Trail, Fort Pierce, FL 34951 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh6868 Structure Btuh2931 Ducts Btuh1059 Ducts Btuh1245Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh7927 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh3984 Method Latent Cooling Equipment Load SizingBlower door Shielding / stories 3 (partial) / 150 Pa / 0 cfmPressure / AVF Structure Btuh1157 Ducts Btuh342Central vent (0 cfm) Btuh0 CoolingHeating (none)654654Area (ft²) Equipment latent load Btuh1499 52345234Volume (ft³)Air changes/hour 0.340.61 Equipment Total Load (Sen+Lat)Btuh5483 Equiv. AVF (cfm) 3053 Req. total capacity at 0.70 SHR ton0.5 Heating Equipment Summary Cooling Equipment Summary Make Generic Make GenericTrade Trade Model SEER 18.0, HSPF 9.1 Cond SEER 18.0, HSPF 9.1AHRI ref Coil AHRI refEfficiency 9.1 HSPF Efficiency 14.7 EER, 18 SEER Heating input Sensible cooling Btuh4200Heating output Btuh @ 47°F5970 Latent cooling Btuh1800 Temperature rise °F27 Total cooling Btuh6000Actual air flow cfm200 Actual air flow cfm200 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.048Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.74Capacity balance point = 45 °F Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 1...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Bed 3 2 Exposed wall 187.3 ft 15.0 ft 3 Room height 8.8 dft 8.0 heat/coolft 4 Room dimensions ft173.8x1.0 5 Room area 1776.8 ft²173.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 414 396 813 681 120 104 214 180 .GG ImpactImpact 0.2600.260 nn 7.547.54 6.936.93 3 0 19 18 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 16 0 136 110 16 0 136 110 .DD DftDoorDftDoor 0.1270.127 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 451 358 736 616 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 12 0 104 258 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 16 0 136 335 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 23 0 200 494 0 0 0 0 GG ImpactImpact 0.3300.330 ee 9.579.57 21.1821.18 42 0 402 890 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 438 411 843 707 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.079.07 4 4 35 36 0 0 0 0 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.979.97 23 0 200 229 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 swsw 2.052.05 1.721.72 44 28 58 49 0 0 0 0 GG ImpactImpact 0.3100.310 swsw 8.998.99 15.3415.34 15 2 136 233 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 224 156 321 269 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 16 0 140 315 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 31 0 280 630 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ww 3.693.69 3.733.73 21 21 77 78 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nwnw 2.052.05 1.721.72 44 28 56 47 0 0 0 0 GG ImpactImpact 0.3100.310 nwnw 8.998.99 15.9715.97 16 0 144 256 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 1777 1777 2819 2172 174 174 276 212 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 1777 187 5373 0 174 15 430 0 6 c) AED excursion 0 -27 Envelope loss/gain 13030 8422 1056 475 12 a) Infiltration 4163 1240 309 92 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 0 0 Appliances/other 3700 200 Subtotal (lines 6 to 13)17193 14282 1365 767 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 8 6 14 Subtotal 17193 14282 1373 773 15 Duct loads 30%41%5217 5869 30%41%417 318 Total room load 22410 20151 1789 1091 Air required (cfm)Air required (cfm)953 953 76 52 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 2...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath 2 Lin 2 Exposed wall 6.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x9.0 ft2.5x3.0 5 Room area 54.0 ft²7.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 48 45 93 78 0 0 0 0 .GG ImpactImpact 0.2600.260 nn 7.547.54 6.936.93 3 0 19 18 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .DD DftDoorDftDoor 0.1270.127 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ee 9.579.57 21.1821.18 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.079.07 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.979.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 swsw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 swsw 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nwnw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 nwnw 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 54 54 86 66 8 8 12 9 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 54 6 172 0 8 0 0 0 6 c) AED excursion -7 0 Envelope loss/gain 370 155 12 9 12 a) Infiltration 124 37 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)494 192 12 9 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 17 13 -12 -9 14 Subtotal 512 205 0 0 15 Duct loads 30%41%155 84 30%41%0 0 Total room load 667 289 0 0 Air required (cfm)Air required (cfm)28 14 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 3...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Hall 2 Exposed wall 26.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft158.8x1.0 ft8.5x3.5 5 Room area 158.8 ft²29.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 112 112 230 193 0 0 0 0 .GG ImpactImpact 0.2600.260 nn 7.547.54 6.936.93 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .DD DftDoorDftDoor 0.1270.127 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 100 84 173 145 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 16 0 136 335 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ee 9.579.57 21.1821.18 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.079.07 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.979.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 swsw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 swsw 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nwnw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 nwnw 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 159 159 252 194 30 30 47 36 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 159 27 760 0 30 0 0 0 6 c) AED excursion 57 -1 Envelope loss/gain 1551 924 47 35 12 a) Infiltration 547 163 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 200 0 Subtotal (lines 6 to 13)2097 1287 47 35 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 15 11 -47 -35 14 Subtotal 2113 1298 0 0 15 Duct loads 30%41%641 534 30%41%0 0 Total room load 2754 1832 0 0 Air required (cfm)Air required (cfm)117 87 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 4...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Laundry Kit/Nook 2 Exposed wall 0.5 ft 20.0 ft 3 Room height 8.0 heat/coolft 9.5 heat/coolft 4 Room dimensions ft6.5x8.0 ft326.0x1.0 5 Room area 52.0 ft²326.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.2600.260 nn 7.547.54 6.936.93 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .DD DftDoorDftDoor 0.1270.127 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 0 0 0 0 114 91 187 157 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 23 0 200 494 GG ImpactImpact 0.3300.330 ee 9.579.57 21.1821.18 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 4 4 8 7 76 53 109 91 GG ImpactImpact 0.3000.300 ss 8.708.70 9.079.07 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.979.97 0 0 0 0 23 0 200 229 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 swsw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 swsw 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nwnw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 nwnw 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 52 52 82 64 326 326 517 398 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 52 1 14 0 326 20 574 0 6 c) AED excursion -20 -126 Envelope loss/gain 105 51 1786 1243 12 a) Infiltration 10 3 490 146 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 500 1700 Subtotal (lines 6 to 13)115 554 2276 3549 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 19 14 14 Subtotal 115 554 2295 3563 15 Duct loads 30%41%35 228 30%41%696 1464 Total room load 150 782 2991 5027 Air required (cfm)Air required (cfm)6 37 127 238 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 5...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Great Room M Lin 2 Exposed wall 32.5 ft 6.0 ft 3 Room height 9.5 heat/coolft 8.0 heat/coolft 4 Room dimensions ft408.3x1.0 ft3.0x3.0 5 Room area 408.3 ft²9.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 0 0 0 0 24 24 49 41 .GG ImpactImpact 0.2600.260 nn 7.547.54 6.936.93 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .DD DftDoorDftDoor 0.1270.127 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 133 91 187 156 24 24 49 41 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ee 9.579.57 21.1821.18 42 0 402 890 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.079.07 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.979.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 swsw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 swsw 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 176 124 254 212 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 31 0 280 630 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ww 3.693.69 3.733.73 21 21 77 78 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nwnw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 nwnw 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 408 408 648 499 9 9 14 11 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 408 33 932 0 9 6 172 0 6 c) AED excursion -139 -4 Envelope loss/gain 2780 2326 285 89 12 a) Infiltration 796 237 124 37 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)3576 3924 409 126 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 12 9 -409 -126 14 Subtotal 3588 3932 0 0 15 Duct loads 30%41%1089 1616 30%41%0 0 Total room load 4676 5548 0 0 Air required (cfm)Air required (cfm)199 262 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 6...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name M Bath Wtr Clst 2 Exposed wall 21.5 ft 6.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft131.5x1.0 ft6.5x4.0 5 Room area 131.5 ft²26.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 40 40 82 69 0 0 0 0 .GG ImpactImpact 0.2600.260 nn 7.547.54 6.936.93 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .DD DftDoorDftDoor 0.1270.127 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 80 68 140 117 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 12 0 104 258 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ee 9.579.57 21.1821.18 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 52 52 107 89 52 48 98 83 GG ImpactImpact 0.3000.300 ss 8.708.70 9.079.07 0 0 0 0 4 4 35 36 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.979.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 swsw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 swsw 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nwnw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 nwnw 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 132 132 209 161 26 26 41 32 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 132 22 617 0 26 7 186 0 6 c) AED excursion 48 -7 Envelope loss/gain 1258 742 361 144 12 a) Infiltration 444 132 134 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1701 874 495 184 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 414 130 0 0 14 Subtotal 2115 1003 495 184 15 Duct loads 30%41%642 412 30%41%150 76 Total room load 2757 1416 645 260 Air required (cfm)Air required (cfm)117 67 27 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 7...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Closet WIC 2 Exposed wall 0 ft 7.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft7.0x3.0 ft7.0x6.0 5 Room area 21.0 ft²42.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.2600.260 nn 7.547.54 6.936.93 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 8.708.70 7.077.07 0 0 0 0 0 0 0 0 .DD DftDoorDftDoor 0.1270.127 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 8.708.70 21.5021.50 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ee 9.579.57 21.1821.18 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 0 0 0 0 56 56 115 96 GG ImpactImpact 0.3000.300 ss 8.708.70 9.079.07 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.979.97 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 swsw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 swsw 8.998.99 15.3415.34 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 8.998.99 20.1820.18 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ww 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nwnw 2.052.05 1.721.72 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 nwnw 8.998.99 15.9715.97 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 21 21 33 26 42 42 67 51 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 21 0 0 0 42 7 201 0 6 c) AED excursion -1 -7 Envelope loss/gain 33 25 382 141 12 a) Infiltration 0 0 144 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)33 25 527 184 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -33 -25 0 0 14 Subtotal 0 0 527 184 15 Duct loads 30%41%0 0 30%41%160 76 Total room load 0 0 687 260 Air required (cfm)Air required (cfm)0 0 29 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 8...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:House Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Suite 2 Exposed wall 45.8 ft 3 Room height 8.8 heat/coolft 4 Room dimensions ft337.3x1.0 5 Room area 337.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Blk Wall, Stucco Ext 0.071 n 2.05 1.72 70 70 144 121 .G Impact 0.260 n 7.54 6.93 0 0 0 0 .G Impact 0.300 n 8.70 7.07 0 0 0 0 .D DftDoor 0.127 n 0.00 0.00 0 0 0 0 11 W Blk Wall, Stucco Ext 0.071 e 2.05 1.72 0 0 0 0 G Impact 0.300 e 8.70 21.50 0 0 0 0 G Impact 0.300 e 8.70 21.50 0 0 0 0 G Impact 0.300 e 8.70 21.50 0 0 0 0 G Impact 0.330 e 9.57 21.18 0 0 0 0 W Blk Wall, Stucco Ext 0.071 s 2.05 1.72 198 198 406 340 G Impact 0.300 s 8.70 9.07 0 0 0 0 G Impact 0.300 s 0.00 0.00 0 0 0 0 G Impact 0.300 s 8.70 9.97 0 0 0 0 W Blk Wall, Stucco Ext 0.071 sw 2.05 1.72 44 28 58 49 G Impact 0.310 sw 8.99 15.34 15 2 136 233 W Blk Wall, Stucco Ext 0.071 w 2.05 1.72 48 33 67 56 G Impact 0.310 w 8.99 20.18 16 0 140 315 G Impact 0.310 w 8.99 20.18 0 0 0 0 D DftDoor 0.127 w 3.69 3.73 0 0 0 0 W Blk Wall, Stucco Ext 0.071 nw 2.05 1.72 44 28 56 47 G Impact 0.310 nw 8.99 15.97 16 0 144 256 C R-20 Icynene 0.405 -1.59 1.22 337 337 535 412 F On Grade, Tile Flr 0.989 -28.68 0.00 337 46 1315 0 6 c) AED excursion 233 Envelope loss/gain 3003 2063 12 a) Infiltration 1042 310 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 200 Subtotal (lines 6 to 13)4045 2573 Less external load 0 0 Less transfer 0 0 Redistribution 17 12 14 Subtotal 4061 2585 15 Duct loads 30%41%1232 1062 Total room load 5294 3648 Air required (cfm)225 173 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-07 13:14:55Right-Suite® Universal 2021 21.0.02 RSU27054 Page 9...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Right-J® Worksheet Oct 29, 2019Date:Mini Split Vicki Lynne BarenbergBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Mini Split Garage 2 Exposed wall 82.5 ft 82.5 ft 3 Room height 8.0 dft 8.0 heat/coolft 4 Room dimensions ft654.3x1.0 5 Room area 654.3 ft²654.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nn 2.052.05 1.721.72 168 150 308 258 168 150 308 258 .GG ImpactImpact 0.2600.260 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG ImpactImpact 0.3000.300 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .DD DftDoorDftDoor 0.1270.127 nn 3.693.69 3.733.73 18 18 66 67 18 18 66 67 11 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ee 2.052.05 1.721.72 80 80 164 138 80 80 164 138 GG ImpactImpact 0.3000.300 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3300.330 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ss 2.052.05 1.721.72 168 152 313 262 168 152 313 262 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3000.300 ss 8.708.70 9.219.21 16 13 136 144 16 13 136 144 GG ImpactImpact 0.3000.300 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 swsw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 ww 2.052.05 1.721.72 244 76 156 131 244 76 156 131 GG ImpactImpact 0.3100.310 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD DftDoorDftDoor 0.1270.127 ww 3.693.69 3.733.73 168 168 620 626 168 168 620 626 WW Blk Wall, Stucco Ext 0.071Blk Wall, Stucco Ext 0.071 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG ImpactImpact 0.3100.310 nwnw 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC R-20 IcyneneR-20 Icynene 0.4050.405 --1.591.59 1.221.22 654 654 1038 800 654 654 1038 800 FF On Grade, Tile Flr 0.989On Grade, Tile Flr 0.989 --28.6828.68 0.000.00 654 83 2366 0 654 83 2366 0 6 c) AED excursion 0 0 Envelope loss/gain 5166 2424 5166 2424 12 a) Infiltration 1702 507 1702 507 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)6868 2931 6868 2931 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 6868 2931 6868 2931 15 Duct loads 15%42%1059 1245 15%42%1059 1245 Total room load 7927 4176 7927 4176 Air required (cfm)Air required (cfm)200 200 200 200 Bold/italic values have been manually overridden 2021-Jan-07 13:14:57 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Duct System Summary Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.550 / 0.150 in H2O in H2O0.550 / 0.150 Lowest friction rate in/100ft0.157in/100ft0.157 Actual air flow cfm953cfm953 Total effective length (TEL) ft446 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3200.031.8VlFx0x04.00.2371634667hBath 2 st3200.030.2VlFx0x07.00.2391041412754hBed 2 st2200.010.8VlFx0x06.00.26162911789hBed 3 st4300.046.1VlFx0x08.00.1591571192774cGreat Room st1205.034.2VlFx0x07.00.2301571192774cGreat Room-A st2200.013.0VlFx0x07.00.258143762514cKit/Nook st3200.028.1VlFx0x07.00.241143762514cKit/Nook-A st2200.011.4VlFx0x04.00.260448782cLaundry st4300.046.8VlFx0x07.00.159801412757hM Bath st1205.038.7VlFx0x07.00.2261041352647hMaster Suite st1205.046.5VlFx0x07.00.2191041352647hMaster Suite-A st4300.044.3VlFx0x04.00.1601535687hWIC st4300.050.2VlFx0x04.00.1571533645hWtr Clst Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st4 Peak AVF 328 267 0.157 601 10.0 0x0 VinlFlx st1 st1 Peak AVF 717 632 0.157 671 14.0 0x0 VinlFlx st2 Peak AVF 175 249 0.258 713 8.0 0x0 VinlFlx st3 Peak AVF 251 263 0.237 595 9.0 0x0 VinlFlx 2021-Jan-07 13:14:57 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb5 0x 1410 104 69.5 0.216 526 7.0 x0 0 VlFx rt1 rb3 0x 3050 222 95.7 0.157 560 10.0 x0 0 VlFx rt1 rb4 0x 910 62 43.3 0.347 465 6.0 x0 0 VlFx rb2 0x 6070 756 62.0 0.243 541 16.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 1052 1082 0.157 496 20.0 0x0 VinlFlx 2021-Jan-07 13:14:57 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 3 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Duct System Summary Oct 29, 2019Date:Mini Split Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 CoolingHeating External static pressure in H2O0in H2O0 Pressure losses in H2O0in H2O0 Available static pressure in H2O0in H2O0 Supply / return available pressure 0.000 / 0.000 in H2O in H2O0.000 / 0.000 Lowest friction rate in/100ft0in/100ft0 Actual air flow cfm200cfm200 Total effective length (TEL) ft0 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 00VlFx0x0002402404176cGarage Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb6 0x 2400 240 0 0 0 0 x0 0 VlFx 2021-Jan-07 13:14:57 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 1 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Manual S Compliance Report Oct 29, 2019Date:House Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Cooling Equipment Design Conditions °F77.0Entering coil DB:Btuh20960Sensible gain:°F90.4Outdoor design DB: °F64.1Entering coil WB:Btuh7159Latent gain:°F77.4Outdoor design WB: Btuh28119Total gain:°F75.0Indoor design DB: cfm953Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: 14ACXS030-230A**+CBA27UHE-030-230*++TDRModel:LennoxManufacturer: cfm953Actual airflow: % of load96Btuh20020Sensible capacity: % of load120Btuh8580Latent capacity: %70SHR:% of load102Btuh28600Total capacity: Heating Equipment Design Conditions °F68.0Entering coil DB:Btuh23932Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm953Actual airflow: °F51Temp. rise:% of load98kW6.9Output capacity: Meets all requirements of ACCA Manual S. 2021-Jan-07 13:14:57 Right-Suite® Universal 2021 21.0.02 RSU27054 Page 2 ...uments\Wrightsoft HVAC\Dunn Residence Groza.rup Calc = MJ8 Front Door faces: W 629Job:Manual S Compliance Report Oct 29, 2019Date:Mini Split Vicki Lynne BarenbergBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Dunn, Groza Builders, IncFor: 0 Slash Pine Trail, Fort Pierce, FL 34951 Cooling Equipment Design Conditions °F76.6Entering coil DB:Btuh4176Sensible gain:°F90.4Outdoor design DB: °F63.4Entering coil WB:Btuh1499Latent gain:°F77.4Outdoor design WB: Btuh5675Total gain:°F75.0Indoor design DB: cfm200Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: SEER 18.0, HSPF 9.1Model:GenericManufacturer: cfm200Actual airflow: % of load101Btuh4200Sensible capacity: % of load120Btuh1800Latent capacity: %70SHR:% of load106Btuh6000Total capacity: Heating Equipment Design Conditions °F69.3Entering coil DB:Btuh7927Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: SEER 18.0, HSPF 9.1Model:GenericManufacturer: cfm200Actual airflow: °F45Capacity balance:% of load75Btuh5970Output capacity: °F-99Economic balance:Btuh1957Supplemental heat required: Meets all requirements of ACCA Manual S. Job #: 629 Performed by Vicki Lynne Barenberg for: Dunn 0 Slash Pine Trail Fort Pierce, FL 34951 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 240 Page 1 Right-Suite® Universal 2021 21.0.02 RSU27054 2021-Jan-07 13:15:58 ...ft HVAC\Dunn Residence Groza.rup N Level 1 Garage Bed 3 Bath 2 Lin Bed 2 Hall Laundry Kit/Nook Great Room M Lin M Bath Wtr Clst Closet WIC Master Suite 10 x 10 157 cfm6 x 6 44 cfm 36 x 18 756 cfm 8 x 4 35 cfm 10 x 10 143 cfm 10 x 10 143 cfm 12 x 8 141 cfm 12 x 12 141 cfm 12 x 12 91 cfm 6 x 6 34 cfm 18 x 18 305 cfm 10 x 10 135 cfm 6 " 20 " 10 " 7 " 4 " 7 " 7 " 4 " 7 " 8 "9 " 10 " 4 " 14 " 7 " 7 " 10 x 10 157 cfm 10 x 10 141 cfm 8 x 4 33 cfm 10 x 10 135 cfm 12 x 8 91 cfm 8 " 7 "4 " 7 " 6 " 0 x 12 240 cfm 0 " 240 cfm Mini Split Wall Mounted