02/14/2019 v date reapplY 02/22/19
Mid -States Asphalt & Cant Strip, Inc.
1637 51st Ave
Tuscaloosa, AL 35401
(205)394-3078
moises@msaroof.com
Moises Rached
molses@msaroof_com
Moises Rached
1637 51st Ave
Tuscaloosa, AL 35401
(205) 469-7101
moises@msarOOf.COm
Moises Rached
1637 51st Ave
Tuscaloosa, AL 35401
(205) 469-2101
moises@msaroof.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - HardcOpy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74071
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2022
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
FL17401 RS CDI MSA170oLZ 2020 FB Eval QUIK-Stick rinal.pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D 1970
2015
TAS 103
2020
TAS 110
2000
UL 1897
2012
Equivalence of Product Standards
Certified by
https:l141oridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQwtDgtCUGgvjQiz6GugLSXh%2bJESYGWxrsQnisUkaU3UhgnbvQ%3d%3d 112
9/812020
Flarida Building Code Online
Sections From the Code
Product Approval Method
Date Submitted
Date Validated
Summant of
FL #
17401.1
Method 1 option D
02/14/2019
09/03/2020
Model, Number or Name
QUIK-Stick Ice & Water Granular,
QUIK-Stick Ice & Water Sand, QUIK-
Stick HT Smooth, QUIK-Stick HT Pro,
QUIK-Stick FS
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +4/-52.5
other: Refer to Evaluation Report for Limitations of Use. Wind
uplift applicable to QUIK-Stick HT only.
Description
Self -Adhered Underlayments
Installation Instructions
FL17401 RS II MSA17001.2 2J20 FBC Fva1 Qum: -Stick
finaI.pdf R. Priest PE-74021
Verified By: Zachary
Created by Independent Third Party: Yes
Evaluation Reports
K-Stick
20 F CQUI
FL4A
l:.ppp L
Created by Independent Third Party: Yes
NIM
ContactUs260k Blau. r Stgne Ingd Tallahassee FL 3239 Phone: 85_� e487-1824 Statemen Refund Statement
The State of Florida is an pgJEEA employee gap ht 2007-20 3 State of Florida.:: Privacy StatementAccessibility _ —��—
hone or traditional mail. If you have any questions, please contact 950.487.1395. "Pursuant to Section 455.275{1},
under Florida law, email addresses are public retards. If you do not want your a -mail address released in response to apublic-records request, do not send e4ectr❑nit
mail to this entity. Instead, contact the office by p Y I a personal address, please
Florida Statutes, effective goober 1, 2012, licensees 4icenseci under Chapter 455, F.S. must provide the Department with an email address if they have and. The le ai s
provided may be used far official communication wlth the licensee. However email addresses are public record. IF you do not wish t❑ supply P
provide the y Department f with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
M W-3 0 ECnEa.
Credit•
Safe
tiE'C'll1"tt�` �f t.TIL It'4
https:llfloridabuilding.orglprlpr app_dti.aspx?param=wGEVXQwtDqtCUGgvjQiz6GugLSXh%2bJESYGWxrsQnisUkaU3UhgnbvQ%3d%3d 212
Certificate of Authorization No, 29824
CREEK
17520 Edinburgh Drive
Tampa, FL 33647
($13) 480-3421
TECHNICAL SERVICES, LLC
EVALUATION REPORT FLORIDA BUILDING CODE, 7T" EDITION (2020)
Manufacturer: MID -STATES ASPHALT AND CANT STRIP, INC. Issued August 31, 2020
1637 51 s` Street
Tuscaloosa, AL 35401
(800)489-2391
wvvw.msaroof.com
Manufacturing Location: Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1504.3.1, 1507.1.1
Properties:
Physical properties
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
BWR-514-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
BWR-522-02-01
ASTM D 1970
201 Sa
PRI Construction Materials Technologies (TST5878)
BWR-533-02-01
TAS 103
2020
PRI Construction Materials Technologies (TST5878)
BWR-534-02-01
ASTM D 1970
ASTM D
2015(2016)
PRI Construction Materials Technologies (TST5878)
BWR-543-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST5878)
WRMI-011-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-007-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST6049)
MSA-026-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-048-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-054-02-01.1
TAS
TAS 103
2020
PRI Construction Materials Technologies (TST6049)
MSA-054-02-01.1
TAS 103
2020
PRI Construction Materials Technologies (TST6049)
MSA-056-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-057-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-060-02-01
ASTM 0 1970
2015a
PRI Construction Materials Technologies (TST6049)
MSA-060-02-02
TAS 103
2020
TAS 110
2000
PRI Construction Materials Technologies (TST6049)
MSA-062-02-01
ASTM D 1623
2017
PRI Construction Materials Technologies (TST6049)
1085T0602
TAS 110
2000
PRI Construction Materials Technologies (TST6049)
1085T0007
ASTM D 1623
2017
MSA17001.2 FL17401-R5 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SEFZVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
MID -STATES ASPHALT AND CANT STRIP, INC
Self -Adhering Underlayments
QUIK-Stick Ice & Water
QUIK-Stick Ice & Water Granular is an ASTM D 1970 self-adhesive undertayment
Granular
constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced
with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x
66.8-ft and has a nominal thickness of 50 mils.
QUIK-Stick Ice & Water Granular is permitted to be used as prescribed in FBC Section
1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure
on the roof deck shall be limited to a maximum 30 days.
QUIK-Stick Ice Water
QUIK-Stick Ice & Water Sand is an ASTM D 1970 self-adhesive underlayment
Sand
constructed from SBS modified asphalt with a fiberglass mat reinforcement and surfaced
with sand. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft
and has a nominal thickness of 50 mils.
QUIK-Stick Ice & Water Sand is permitted to be used as prescribed in FBC Section
1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure
on the roof deck shall be limited to a maximum 30 days.
QUIK-Stick HT Smooth
QUIK-Stick HT Smooth is an ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind
Concrete and Clay Tile Installation Manual, Sixth Edition compliant self-adhesive
underlayment constructed from SBS modified asphalt with a fiberglass mat
reinforcement and woven poly -fabric surface. The product is supplied in 2-sq. rolls with
nominal dimensions of 3-ft x 66.8-ft or 3-ft 3-in x 61-ft and has a nominal thickness of 60
mils.
QUIK-Stick HT Smooth (Woven Facer) is to be used as prescribed in FBC Section
1507.1.1 and Table 1507.1.1.1. QUIK-Stick HT is permitted to be used with
mechanically attached or adhered clay or concrete tile roofing using either ICP
'n
Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.), DAP Touch Seal9)
Storm Bond Roof Tile Adhesive or DuPontTm TILE BONDYm Roof Tile Adhesive.
Exposure on the roof deck shall be limited to a maximum 90 days_
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens_ Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
rQUIK-Stick HT Pro
QUIK-Stick HT Pro is an ASTM D 1970 self-adhesive underlayment constructed from
SSS modified asphalt with a fiberglass mat reinforcement and poly -fabric surface. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a
nominal thickness of 60 mils.
QUIK-Stick HT Pro is permitted to be used as prescribed in FBC Section 1507.1.1 and
Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof
deck shall be limited to a maximum 30 days.
QUIK-Stick FS QUIK-Stick FS is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt with a fiberglass mat reinforcement and textured film surface. The
product is supplied in 2-sq. roils with nominal dimensions of 3-ft x 66.8-ft and has a
nominal thickness of 45 mils.
QUIK-Stick FS is permitted to be used as prescribed in FBC Section 1507.1.1 and Table
1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall
be limited to a maximum 30 days.
MSA17001.2 FL17401-R5 Page 2 of
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify GREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRnni1CT APPLICATION
MID -STATES ASPHALT AND CANT STRIP, INC
Self -Adhering Underlayments
Min. Roof Slope: 2:12 or in accordance in with the FBC
Application: All underlayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum B" end laps staggered min. B ft.from preceding course.
It is permissible to back nail the underayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment).
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1 — QUIK-Stick Hi Smooth only
Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: QUIK-Stick HT Smooth shall be fully adhered to the optionally primed plywood deck.
Maximum Design -52.5 psf
Pressure:
MSA17001.2 FL17401-R5 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS '
MID -STATES ASPHALT AND CANT STRIP, INC
Self -Adhering Underlayments
1) This evaluation report is not for use in the HVHZ_
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions_ Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 70' Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
�NOr,►R�r i rR rrA����i
-.
tiP•'��.�GENSF • SJ�
1 No 74021 l
N
3 STATE OF :4UZ
:�.n • A'� O R , P �N -Z'
/ 0 N AL �t�`��,
��rrrnr111"
CERTIFICATION OF INDEPENDENCE
2020.08.31
14:10:07
-04' 00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
MSA17001.2 FL17401-R5 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.