Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BROWN RESIDENCE Builder Name: DAVE GOLDEN HOMES Street: 3601 ARNOLD ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: BETH BROWN Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1508.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead Aggl=4.1 1268.00 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1414.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1414.00 ft2 6. Conditioned floor area above grade (ft2) 1414 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(160.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 130 a. U-Factor: Sgl, U=0.58 160.00 ft2 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 3.958 ft. Area Weighted Average SHGC: 0.240 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1414.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1414.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 47.39 Glass/Floor Area: 0.113 PASS Total Baseline Loads: 52.01 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: - -'02Y this building will be inspected for 0, compliance with Section 553.908 I hereby certify that this buildi designed, is in ompliance Florida Statutes. �,S, with the Florida Energy CodOWNER/AGENT-BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9/14/2020 5:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1),- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BROWN RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1414 Lot # Owner Name: BETH BROWN Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: DAVE GOLDEN HOMES Rotate Angle: 0 Street: 3601 ARNOLD ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/E)asting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1414 12338 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 152 1216 No 0 1 1 Yes Yes Yes 2 CLST 3 18 144 No 0 1 Yes Yes Yes 3 BATH 3 72 576 No 0 1 Yes Yes Yes 4 CLST 2 18 144 No 0 1 Yes Yes Yes 5 BEDROOM 2 151 1208 No 0 1 1 Yes Yes Yes 6 HALL 32 256 No 0 1 No Yes Yes 7 KITCHEN 266 2660 Yes 0 1 Yes Yes Yes 8 GREAT RM 247 2470 No 0 1 Yes Yes Yes 9 MASTER BEDROO 210 1680 No 0 1 1 Yes Yes Yes 10 M WIC 70 560 No 0 1 Yes Yes Yes 11 M BATH 94 752 No 0 1 Yes Yes Yes 12 LAUNDRY 48 384 No 0 1 No Yes Yes 13 AHU CLST 9 72 No 0 1 No Yes Yes 14 ENTRY HALL 27 216 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 3 25 ft 0 152 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulatio CLST 3 2 ft 0 18 ft2 ---- 1 0 0 3SIab-On-Grade Edge Insulatio BATH 3 8 it 0 72 ft2 1 0 0 4SIab-On-Grade Edge Insulatio CLST" 2 2 ft 0 18 ft2 ____ 1 0 0 9/14/2020 5:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5SIab-On-Grade Edge Insulatio BEDROOM 2 32 ft 0 151 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulatio HALL 1 ft 0 32 ft2 ---- 1 0 0 7SIab-On-Grade Edge Insulatio KITCHEN 19 ft 0 266 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio GREAT RM 19 ft 0 247 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio MASTER BEDRO 15 ft 0 210 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio M WIC 17 ft 0 70 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio M BATH 10 ft 0 94 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 48 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulatio AHU CLST 1 ft 0 9 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulatio ENTRY HALL 1 ft 0 27 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1532 ft2 0 ft2 Medium N 0.3 No 0.9 No 20 22.6 ATTIC v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1414 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 3 0 Blown 152 ft2 0.1 Wood 2 Under Attic (Unvented) CLST 3 0 Blown 18 ft2 0.1 Wood 3 Under Attic (Unvented) BATH 3 0 Blown 72 ft2 0.1 Wood 4 Under Attic (Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 5 Under Attic (Unvented) BEDROOM 2 0 Blown 151 ft2 0.1 Wood 6 Under Attic (Unvented) HALL 0 Blown 32 ft2 0.1 Wood 7 Under Attic (Unvented) KITCHEN 0 Blown 266 ft2 0.1 Wood 8 Under Attic (Unvented) GREAT RM 0 Blown 247 ft2 0.1 Wood 9 Under Attic (Unvented) MASTER BEDRO 0 Blown 210 ft2 0.1 Wood 10 Under Attic (Unvented) M WIC 0 Blown 70 ft2 0.1 Wood 11 Under Attic (Unvented) M BATH 0 Blown 94 ft2 0.1 Wood 12 Under Attic (Unvented) LAUNDRY 0 Blown 48 ft2 0.1 Wood 13 Under Attic (Unvented) AHU CLST 0 Blown 9 ftz 0.1 Wood 14 Under Attic (Unvented) ENTRY HALL 0 Blown 27 ft2 0.1 Wood 9/14/2020 5:27 PM • EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity 13-1/all le Width Et In Height Et In Arnm Sheathing Framing 13-Vallie Fraction Solar Ahcznr Belo (' w l. 1 N Exterior Concrete Block - PolysllkBROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 2 W Exterior Concrete Block - PolysWDROOM 3 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 3 W Exterior Concrete Block - Polystyre6LST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0 4 W Exterior Concrete Block - PolystyrdaATH 3 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 W Exterior Concrete Block - Polystyre6LST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.3 0 6 E Exterior Concrete Block - PolystpMROOM 2 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 7 S Exterior Concrete Block - PolystWDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 8 W Exterior Concrete Block - PolysoODROOM 2 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 9 N Exterior Concrete Block - PolystyrthTCHEN 4.1 19 0 10 0 190.0 ft2 0 0 0.3 0 10 S Exterior Concrete Block - PolystyMEAT RM 4.1 19 0 10 0 190.0 ft? 0 0 0.3 0 11 E Garage Frame - Wood GREAT RM 11 4 0 10 0 40.0 ft2 0 0.1 0.3 0 12 N Exterior Concrete Block - PolystV&STER BE 4.1 15 0 8 0 120.0 ft2 0 0 0.3 0 13 N Exterior Concrete Block - PolystyreM WIC 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 14 E Exterior Concrete Block - PolystyreM WIC 4.1 10 0 8 0 80.0 ft2 0 0 0.3 0 _ 15 E Exterior Concrete Block - Polystyrdd BATH 4.1 10 0 8 0 80.0 ft2 0 0 0.3 0 16 S Garage Frame - Wood M BATH 11 11 0 8 0 88.0 ft2 0 0.1 0.3 0 17 S Garage Frame - Wood LAUNDRY 11 5 0 8 0 40.0 ft2 0 0.1 0.3 0 18 S Garage Frame - Wood AHU CLST 11 3 0 8 0 24.0 ft2 0 0.1 0.3 0 19 E Garage Frame - Wood AHU CLST 11 3 0 8 0 24.0 ft2 0 0.1 0.3 0 20 S Garage Frame - Wood ENTRY HALL 11 3 0 8 0 24.0 ft2 0 0.1 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated GREAT RM None .27 3 8 24 ft2 2 S Insulated ENTRY HALL None .23 3 6 8 20 ftz WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.58 0.24 Y 15.0 ft2 1 ft 4 in 1 ft 4 in None None 2 W 4 Metal Low-E Single Yes 0.58 0.24 Y 6.0 ft2 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 3 S 7 Metal Low-E Single Yes 0.58 0.24 Y 30.0 ft2 1 ft 4 in 1 ft 4 in None None 4 N 9 Metal Low-E Single Yes 0.58 0.24 Y 9.0 ft2 1 ft 4 in 1 ft 4 in None None 5 N 9 Metal Low-E Single Yes 0.58 0.24 Y 20.0 ft2 11 ft 4 in 1 ft 4 in None None 6 S 10 Metal Low-E Single Yes 0.58 0.24 Y 36.0 ft2 6 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 7 S 10 Metal Low-E Single Yes 0.58 0.24 Y 8.0 ft2 6 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 8 N 12 Metal Low-E Single Yes 0.58 0.24 Y 30.0 ft2 1 ft 4 in 1 ft 4 in None None 9 E 15 Metal Low-E Single Yes 0.58 0.24 Y 6.0 ft2 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 9/14/2020 5:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 572 ftz 572 ftz r34 ft - 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000388 1439.4 79.02 148.61 .1392 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM / FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS V # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 130 ftz Attic 13 ft2 Default Leakage Garage (Default) (Default) 1 1 9/14/2020 5:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 • f FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar Apr Ma X Jun Jul Aug Se Oct ] Nov Dec Heatin1XIJan H Feb Mar ki �Xj APr I May Jun f Jul Au ri Sep f Oct f X] Nov 0 XDec Ventin Jan Feb Mar Apr May [ Jun [ Jul Aug Se [ Oct Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 66 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/s .ft. ft2 ft 0.3 ENTRY HALL 9/14/2020 5:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 r d 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 RECEIVED 4. Number of bedrooms 4. 3 13. Cooling system: Capacity p-2rg a) Split system SEER 16.0 T028 5. Is this a worst case? (yes/no) 5. No b) Single package SEER f c) Ground/water source SEER/COP WNP� em 6. Conditioned floor area (sq. ft.) 6. 1414 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor: (weighted average) 7a. 0.580 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.240 14. Heating system: Capacity 17.0 c) Area 7c. 160.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has co pied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be ' Called (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be complet d ased on installed code compliant features. Builder Signature: Date: ZOL� Address of New Home: 3601 ARNOLD ROAD City/FL Zip: FORT PIERCE, FL 9/14/2020 5:28:22 PM I EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1