HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BROWN RESIDENCE
Builder Name: DAVE GOLDEN HOMES
Street: 3601 ARNOLD ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: BETH BROWN
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1508.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead Aggl=4.1 1268.00 ft2
b. Frame - Wood, Adjacent
R=11.0 240.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1414.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1414.00 ft2
6. Conditioned floor area above grade (ft2) 1414
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(160.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 130
a. U-Factor: Sgl, U=0.58 160.00 ft2
SHGC: SHGC=0.24
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
24.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.958 ft.
Area Weighted Average SHGC: 0.240
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1414.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 1414.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Total Proposed Modified Loads: 47.39
Glass/Floor Area: 0.113
PASS
Total Baseline Loads: 52.01
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: - -'02Y
this building will be inspected for
0,
compliance with Section 553.908
I hereby certify that this buildi designed, is in ompliance
Florida Statutes.
�,S,
with the Florida Energy CodOWNER/AGENT-BUILDING
OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9/14/2020 5:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1),- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: BROWN RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1414
Lot #
Owner Name: BETH BROWN
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: DAVE GOLDEN HOMES
Rotate Angle: 0
Street:
3601 ARNOLD ROAD
Permit Office: ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type: Single-family
FL,
New/E)asting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1414
12338
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 BEDROOM 3 152
1216 No
0
1
1
Yes
Yes
Yes
2 CLST 3 18
144 No
0
1
Yes
Yes
Yes
3 BATH 3 72
576 No
0
1
Yes
Yes
Yes
4 CLST 2 18
144 No
0
1
Yes
Yes
Yes
5 BEDROOM 2 151
1208 No
0
1
1
Yes
Yes
Yes
6 HALL 32
256 No
0
1
No
Yes
Yes
7 KITCHEN 266
2660 Yes
0
1
Yes
Yes
Yes
8 GREAT RM 247
2470 No
0
1
Yes
Yes
Yes
9 MASTER BEDROO 210
1680 No
0
1
1
Yes
Yes
Yes
10 M WIC 70
560 No
0
1
Yes
Yes
Yes
11 M BATH 94
752 No
0
1
Yes
Yes
Yes
12 LAUNDRY 48
384 No
0
1
No
Yes
Yes
13 AHU CLST 9
72 No
0
1
No
Yes
Yes
14 ENTRY HALL 27
216 No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 3 25 ft 0
152 ft2
____
1 0
0
2 Slab -On -Grade Edge Insulatio CLST 3 2 ft 0
18 ft2
----
1 0
0
3SIab-On-Grade Edge Insulatio BATH 3 8 it 0
72 ft2
1 0
0
4SIab-On-Grade Edge Insulatio CLST" 2 2 ft 0
18 ft2
____
1 0
0
9/14/2020 5:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
5SIab-On-Grade Edge Insulatio
BEDROOM 2 32 ft
0
151 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
HALL 1 ft
0
32 ft2
----
1
0
0
7SIab-On-Grade Edge Insulatio
KITCHEN 19 ft
0
266 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulatio
GREAT RM 19 ft
0
247 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulatio
MASTER BEDRO 15 ft
0
210 ft2
----
1
0
0
10SIab-On-Grade Edge Insulatio
M WIC 17 ft
0
70 ft2
----
1
0
0
11SIab-On-Grade Edge Insulatio
M BATH 10 ft
0
94 ft2
----
1
0
0
12SIab-On-Grade Edge Insulatio
LAUNDRY 1 ft
0
48 ft2
----
1
0
0
13SIab-On-Grade Edge Insulatio
AHU CLST 1 ft
0
9 ft2
----
1
0
0
14SIab-On-Grade Edge Insulatio
ENTRY HALL 1 ft
0
27 ft2
----
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 1532 ft2
0 ft2
Medium
N
0.3
No 0.9
No 20
22.6
ATTIC
v # Type
Ventilation Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Unvented
0
1414 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Unvented)
BEDROOM 3
0
Blown
152 ft2
0.1
Wood
2 Under Attic (Unvented)
CLST 3
0
Blown
18 ft2
0.1
Wood
3 Under Attic (Unvented)
BATH 3
0
Blown
72 ft2
0.1
Wood
4 Under Attic (Unvented)
CLST 2
0
Blown
18 ft2
0.1
Wood
5 Under Attic (Unvented)
BEDROOM 2
0
Blown
151 ft2
0.1
Wood
6 Under Attic (Unvented)
HALL
0
Blown
32 ft2
0.1
Wood
7 Under Attic (Unvented)
KITCHEN
0
Blown
266 ft2
0.1
Wood
8 Under Attic (Unvented)
GREAT RM
0
Blown
247 ft2
0.1
Wood
9 Under Attic (Unvented)
MASTER BEDRO
0
Blown
210 ft2
0.1
Wood
10 Under Attic (Unvented)
M WIC
0
Blown
70 ft2
0.1
Wood
11 Under Attic (Unvented)
M BATH
0
Blown
94 ft2
0.1
Wood
12 Under Attic (Unvented)
LAUNDRY
0
Blown
48 ft2
0.1
Wood
13 Under Attic (Unvented)
AHU CLST
0
Blown
9 ftz
0.1
Wood
14 Under Attic (Unvented)
ENTRY HALL
0
Blown
27 ft2
0.1
Wood
9/14/2020 5:27 PM • EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity
13-1/all le
Width
Et In
Height
Et In
Arnm
Sheathing Framing
13-Vallie Fraction
Solar
Ahcznr
Belo
(' w
l.
1
N
Exterior
Concrete Block - PolysllkBROOM 3
4.1
13
0
8
0
104.0 ft2
0
0
0.3
0
2
W
Exterior
Concrete Block - PolysWDROOM 3
4.1
12
0
8
0
96.0 ft2
0
0
0.3
0
3
W
Exterior
Concrete Block - Polystyre6LST 3
4.1
2
0
8
0
16.0 ft2
0
0
0.3
0
4
W
Exterior
Concrete Block - PolystyrdaATH 3
4.1
8
0
8
0
64.0 ft2
0
0
0.3
0
5
W
Exterior
Concrete Block - Polystyre6LST 2
4.1
2
0
8
0
16.0 ft2
0
0
0.3
0
6
E
Exterior
Concrete Block - PolystpMROOM 2
4.1
8
0
8
0
64.0 ft2
0
0
0.3
0
7
S
Exterior
Concrete Block - PolystWDROOM 2
4.1
13
0
8
0
104.0 ft2
0
0
0.3
0
8
W
Exterior
Concrete Block - PolysoODROOM 2
4.1
11
0
8
0
88.0 ft2
0
0
0.3
0
9
N
Exterior
Concrete Block - PolystyrthTCHEN
4.1
19
0
10
0
190.0 ft2
0
0
0.3
0
10
S
Exterior
Concrete Block - PolystyMEAT RM
4.1
19
0
10
0
190.0 ft?
0
0
0.3
0
11
E
Garage
Frame - Wood GREAT RM
11
4
0
10
0
40.0 ft2
0
0.1
0.3
0
12
N
Exterior
Concrete Block - PolystV&STER BE
4.1
15
0
8
0
120.0 ft2
0
0
0.3
0
13
N
Exterior
Concrete Block - PolystyreM WIC
4.1
7
0
8
0
56.0 ft2
0
0
0.3
0
14
E
Exterior
Concrete Block - PolystyreM WIC
4.1
10
0
8
0
80.0 ft2
0
0
0.3
0
_ 15
E
Exterior
Concrete Block - Polystyrdd BATH
4.1
10
0
8
0
80.0 ft2
0
0
0.3
0
16
S
Garage
Frame - Wood M BATH
11
11
0
8
0
88.0 ft2
0
0.1
0.3
0
17
S
Garage
Frame - Wood LAUNDRY
11
5
0
8
0
40.0 ft2
0
0.1
0.3
0
18
S
Garage
Frame - Wood AHU CLST
11
3
0
8
0
24.0 ft2
0
0.1
0.3
0
19
E
Garage
Frame - Wood AHU CLST
11
3
0
8
0
24.0 ft2
0
0.1
0.3
0
20
S
Garage
Frame - Wood ENTRY HALL
11
3
0
8
0
24.0 ft2
0
0.1
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated GREAT RM
None
.27
3
8
24 ft2
2
S
Insulated ENTRY HALL
None
.23
3
6 8
20 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Single Yes
0.58
0.24
Y
15.0 ft2
1 ft 4 in
1 ft 4 in
None
None
2
W 4
Metal Low-E Single Yes
0.58
0.24
Y
6.0 ft2
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
3
S 7
Metal Low-E Single Yes
0.58
0.24
Y
30.0 ft2
1 ft 4 in
1 ft 4 in
None
None
4
N 9
Metal Low-E Single Yes
0.58
0.24
Y
9.0 ft2
1 ft 4 in
1 ft 4 in
None
None
5
N 9
Metal Low-E Single Yes
0.58
0.24
Y
20.0 ft2
11 ft 4 in
1 ft 4 in
None
None
6
S 10
Metal Low-E Single Yes
0.58
0.24
Y
36.0 ft2
6 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
7
S 10
Metal Low-E Single Yes
0.58
0.24
Y
8.0 ft2
6 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
8
N 12
Metal Low-E Single Yes
0.58
0.24
Y
30.0 ft2
1 ft 4 in
1 ft 4 in
None
None
9
E 15
Metal Low-E Single Yes
0.58
0.24
Y
6.0 ft2
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
9/14/2020 5:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
572 ftz
572 ftz
r34 ft - 8 ft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000388
1439.4 79.02 148.61 .1392 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 17 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 24 kBtu/hr 720 cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
/
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ftz
DUCTS
V #
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 130 ftz
Attic
13 ft2 Default Leakage Garage (Default) (Default)
1 1
9/14/2020 5:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
• f
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan
Feb
Mar
Apr
Ma
X Jun
Jul
Aug
Se
Oct
] Nov
Dec
Heatin1XIJan H
Feb
Mar
ki
�Xj
APr
I
May
Jun
f Jul
Au
ri
Sep
f Oct f X] Nov
0
XDec
Ventin Jan
Feb
Mar
Apr
May
[ Jun
[ Jul
Aug
Se
[ Oct Nov
[ Dec
Thermostat Schedule: HERS
2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
66
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8 Ibs/s .ft.
ft2
ft
0.3
ENTRY HALL
9/14/2020 5:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
r
d
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Garage
3. No. of units (if multiple -family)
3.
1
RECEIVED
4. Number of bedrooms
4.
3
13. Cooling system: Capacity p-2rg
a) Split system SEER 16.0 T028
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER f
c) Ground/water source SEER/COP
WNP� em
6. Conditioned floor area (sq. ft.)
6.
1414
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor: (weighted average)
7a.
0.580
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.240
14. Heating system: Capacity
17.0
c) Area
7c.
160.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance
Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
No
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has co pied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be ' Called (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be complet d ased on installed code compliant features.
Builder Signature: Date: ZOL�
Address of New Home: 3601 ARNOLD ROAD City/FL Zip: FORT PIERCE, FL
9/14/2020 5:28:22 PM I EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1