Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revisions; Add Details for Window Install
OFFICE USE ONLY: DATE FILED: REVISION FEE: (� PERMIT # RECEIPT # Q Q2 t—I 1 PLANNING & DEVELOPMENT SERVICES BUILDING & CODEREGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: Ocean nP ��� y © J-/ J 10701 S. Ocean Drive Lot #866 JF .,� Jensen Beach, FL 34957 RECEIVED DEC 22 2020 Permitting Department St. Lude county DETAILED DESCRIPTION OF PROJECT REVISIONS: . Add detail for window install. it was not on original plans per review. Request change center bean attachment CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC13232 BUSINESS NAME: JWN Builders QUALIFIERS NAME: James Newman ADDRESS: 1701 SE Carvalho Street CITY: Port St. Lucie STATE: FL PHONE (DAYTIME): 772-201-8947 OWNER/BUILDER INFORMATION: NAME: Mark Tlumacki ADDRESS:10701 S. Ocean Drive Lot #866 CITY: Jensen Beach ST PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130117 ST. LUCIE CO CERT. #: 18615 ZIP: 34983 FAX: 772-871-9500 FL ZIP; 34957 FAX: FILE COPY ZIP: FAX: --- -- DEMOLITION NOTES AND LEGEND 1. CONTRACTOR TO FIELD VERIFY EXIST. CONDITIONS AND CROSS CHECK WITH THE DWG5 AND IF THEIR ARE ANY DESCREPENCIE5 TO NOTIFY THE ARCHITECT BEFORE PROCEEDING WITH WORK EXIST. AREAS TO BR REMOVED ❑1 REMOVE EXIST WALL ® REMOVE EXIST KITCHEN 3� REMOVE EXIST WINDOW AND FRAME IN ® REMOVE EXIST WINDOW FRAME IN PUT THE EXIST WINDOW OVER NEW KITCHEN SINK 0 ❑7 F—k 1Tm%/ THE STRUCTURAL ACCORDANCE WITH THE 6 TH EDITION 2017 FLORIDA BUILDING CODE 2017 THE FOLLOWING SUPERIMPOSED LOADING HAVE BEEN UTILIZED. KEYNOTES ROOF LIVE LOAD: 30 PSF SYSTEM FOR THE BUILDING HAS BEEN DESIGNED IN DEAD LOAD: 25 P5F EXIST DONT USE 33% STRESS INCREASES FOR ROOF TRUSSES WIND LOAD 170 MPH AS PER ASCE 7-10 RISK CATT.II NEW 2x4 WOOD STUDS @ 16" O.C. EXPOSURE " C " ® NON STRUCTURAL WIND DIRECTIONALITY FACTOR =.85 INTERNAL PRESSURE COEFFICIENTT = 0.1.18 NEW 2x4 WI) STUD WALL CODES W/ R-11 INSUL FLORIDA BUILDING CODE 2017 RESIDENTIAL, LOCAL CODES AND GOVERNING REGULATONS. ACI 318-02 NEW 2x4 WD STUD WALL ACI 421.1-R92 W/ R-11 IN5UL A.I.S.C. NINTH EDITION N.D.5. 2001 lO NEW RANGE / OVEN A5CE 7-02 02 NEW REF. O3 NEW DBL SINK W/ GARB. DISP ® NEW DISHWASHER EXIST H. 2 © 2-3�i'X11�4� PARALLAM BEAM 2.OE ® 4 x 4 WOOD POST DOOR SCHEDULE SIZE MARK TYPE & MAT. W H THK. AO 21_8" 6'-8" 1-3/4" WOOD/ W/ RAISED PANEL O 2'_6" 6'-8" 1-3/4" WOOD/ W/ RAISED PANEL O 4' 0" 6'-8" 1-3/4" WOOD BI FOLD RAISED PANEL 5'-0" 6'-8" WOOD SLIDING pO RAISED PANEL NEW 31" x 38 %" SINGLE HUNG EXIST. ® WINDOW IMPACT BY PGT PRODUCT APPROVAL # 20-0401.11 EXIST. EXP. DATE AUG 23, 2023 09 EXIST WINDOW RELOCATED FROM EXIST. THE EXIST KITCHEN LOCATION ®0 NEW 4 x 4 WOOD POST 2 @1 NEW 2 - 2 x 12 WOOD HDR W/ NEW 2 x 4 WOOD STUDS AT EA END EXIST. EXIST. IJ—�J Go N 12 -0' BEDROOM A5T OO EXIST. - N i I cD 6" o% 8'-2.1 i7'-11121. .I 61. LIVING KITCHEN 3'-6j' ® I B O i M. AT - © O I 0y 8 N O T -0" 2 -8" CLOS. HW HW N ❑ EXIST. AB2 2 N 41. EXIST. EXIST BAT AI IS B I I V A 7'-4" A-2 7'-4" I A-2 EXIST BEDROOM3'-011 4'-10" � 3'-C 11 I EDE ❑1 I I' A ❑ = N 4 \ ❑ 20'- I.II 2 o Lt N 10'-8"7TE it IST BATH 1 M KITCHEN F , 91 _ I �o ® XLIVING NEWA---- o 1 oN �, AA TER BEDROOM 2 EXIST. EXIST EX ST. DEMOLITION PLAN PLAN /4'=1,_0.. FLOOR PLAN 1/I._1'-0.. 74 - GENERAL NOTES NEW APPLIANCES ARE TO BE WIRED TO THE EXIST APPLIANCE CIRCUITS NEW RECEPTACLES ARE TO BE WIRED TO THE SAME CIRCUIT AS TH05E THAT ARE TO BE REMOVED. IF NEW RECEPTALES ARE NOT REPLACING EXIST THEY ARE TO BE WIRED TO SPARES ON EXIST. PNL ALL NEW RECEPTACLES IN THE KITCHEN ARE TO BE WIRED TO THE SMALL APPLIANCE CIRCUITS IN THE EXIST PANEL AND ARE TO BE GFI' 5 E SYMBOL LEGEND RECESSED LED LIGHT ® SPECIAL RECEPTACLE OUTLET 240V JQr DUPLEX RECEPTACLE OUTLET DEDICATED RECEPTACLE OUTLET GROUND FAULT INTERCEPTOR RECEPTA NEW LED HI HAT QO RECESSED CAN LTS (GM)SMOKE DETECTOR AND CARBON DIOXID EXHAUST FAN PLUMBING SCHEDULE DESCRIPTION FIXTURE COLD WATER HOT WATER SANITARY LINE REMARKS UNIT COUNT SUPPLY SUPPLY SIZE TO VENT LAVATORY 1 1/211 1/2" 1/2" COUNTERTOP SHOWER 2 1/2" 1/211 2" BIDET 2 1/2" 1/2" 2" TUB 2 1/2" 1/2" 2" WHIRLPOOL TUB 2 1/2" 1/2" 1/2" WATER CLOSET 4 1/2"' - 3" KITCHEN SINKS 2 1/2" 1/2" 1/2" COUNTER TOP REFRIGERATOR - 1/2" - - SHUT OFF VALVE DISHWASHER 2 - 1/2" 3/4" SAFE WASTED TO KITCH WASHER 1 4 1 1/2" 1/2" 2 LAUNDRY SINKH 2 1/2" 1/2" 1 1/2" COUNTERTOP H05E BIBS - 1/2" A/C DRAIN - - - 3/4" PVC SCHEDULE 40 N SINK PLUMBING NOTES - PROVIDE SHUT-OFF VALVE FOR EACH FIXTURE. - MATERIALS SHALL BE AS FOLLOWS: 1) COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE TYPE "L" RECEIVED COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE GROUND. "K" 2 21010 2) COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE SOFT COPPER DEC INSTALLED INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB. E 3) SANITARY WASTE AND VENT 4" DIA. AND SMALLER SHALL BE PVC P,,MltongQeaartment St. LU"e CoUntl 4) STORM LINES INSIDE BUILDING SHALL BE PVC SCHEDULE 40. STORM LINES OUTSIDE BUILDING SHALL BE PVC SCHEDULE 80, 5) IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF - BUILDING SHALL BE PVC SCHEDULE 40. EXIST VENT THRU ROOF 6) CONDENSATE DRAIN PIPE SHALL BE PVC SCHEDULE 40 PIPE AND FITTINGS. 7) WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER GAR DISP ELECTRICAL FLOOR PLAN Y4 1._1 _O.. q _ PLUMBING FLOOR PLAN ITO EXIST MAIN AV F.U. 3 v4FU %2' WR.U. _UMBING RISER DIAGRAM N.T.5. viJ� ,2, C ►IEWED FOR EXI5T MAIfTY NT OVER TO O EXIST VENT w �c �o 00 r- w M N A� ~ ® v t` N � a h W W r oo 3 en M r C) O U E~ � `O ® a �i plo Q_ ILI oc O C) Q z� z o Z 0 U U N \\tllllllll//� / 2 O.•'�\C N \ N 52046 / N LT. �O nr �•. \ A oo Q O IS,/ •.... • 'N