HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-49
Builder Name: GHO BUILDERS
Street: 9614 KNOLLWOOD LN
Permit Office: ST. LUCIE COUNTYLNOV12020
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner:
Jurisdiction:
nty, permitting
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Clim
1. New construction or existing New (From Plans)
9. Wall Types (2473.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2163.40 ftZ
b. Frame - Wood, Adjacent
R=11.0 309.78 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. Number of Bedrooms 3
d. N/A
R= ftZ
5. 'is this a worst case? No
10. Ceiling Types (2407.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=40.0 2407.00 ftZ
6. Conditioned floor area above grade (ftZ) 2407
b. N/A
R= ftZ
Conditioned floor area below grade (ftZ) 0
c.
R= ftZ
11. Ducts
R ftZ
7. Windows(434.5 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 648
a. U-Factor: Dbl, U=0.62 434.49 ftZ
SHGC: SHGC=0.26
b. U-Factor: N/A ftZ
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
47.0 SEER:16.00
' c. U-Factor: N/A ftZ
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftZ
a. Electric Strip Heat
29.5 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 8.958 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2407.0 sgft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2407.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
15. Credits
Pstat
Glass/Floor Area: 0.181 Total Proposed Modified Loads: 77.32
PASS
Total Baseline Loads: 81.63
I hereby certify that the plans and specifications covered by
Review of the plans and
tuE ST.gT
this calculation are in compliance with the Florida Energy
specifications covered by this
ti� = s 0,�,
Code.
calculation indicates compliance
cyii'
`O
with the Florida Energy Code.
nNrs911 'n :::.•;:"��,ti
PREPARED BY:
Before construction is completed
DATE: 10/1/2020
this building will be inspected for
compliance with Section 553.908
�
* "�
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
l ��
with the Florida Energy Code.
COD WE
OWNER/AGEr. MA
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Gompliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-49
User
1
GHO BUILDERS
ST. LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2407
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 9614 KNOLLWOOD LN
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
2407 24551.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2407 24551.4 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 217.9 ft 0
2407 ft2 ---- 0 0 1
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip Flat tile/slate 2692 ft2 0 ft2 Medium
N 0.4 N 0.9 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 2407 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 40 Blown
2407 ft2 0.1 Wood
10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHFCKI _IST RFPnRT
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing Solar
Below
Ornt
To
Wall
Type
R-Value
Ft
In
EtInArea
R-Value-Fraction-AAbsor.-Gradeo-
1
N
Exterior
Concrete Block - Ext Insul
Main
4.1
63
2
9 4
589.6 f12
0
0
0.3
0
2
NE
Exterior
Concrete Block - Ext Insul
Main
4.1
8
7
11 4
97.3 ft2
0
0
0.3
0
_ 3
E
Exterior
Concrete Block - Ext Insul
Main
4.1
55
9
9 4
520.3 ft2
0
0
0.3
0
4
SE
Exterior
Concrete Block - Ext Insul
Main
4.1
2
11
11 4
33.1 ft2
0
0
0.3
0
5
S
Exterior
Concrete Block - Ext Insul
Main
4.1
36
2
11 4
409.9 ft2
0
0
0.3
0
6
W
Exterior
Concrete Block - Ext Insul
Main
4.1
55
0
9 4
513.3 ft2
0
0
0.3
0
7
-
Garage
Frame - Wood
Main
11
27
4
11 4
309.8 ft2
0
0.25
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Wood Main
None
.39
6
2
12 ft2
WINDOWS,
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame
Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
7.0 ft2
2 ft 0 in
3 ft 0 in
None
None
•
2
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
43.3 ft2
2 ft 0 in
3 ft 0 in
None
None
3
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
31.6 ft2
6 ft 0 in
1 ft 0 in
None
None
4
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
111.6 ft2
14 ft 0 in
1 ft 0 in
None
None
5
ne
2
Metal
Double (Clear)
Yes
0.62
0.26
N
22.5 ft2
7 ft 0 in
1 ft 0 in
None
None
6
ne
2
Metal
Double (Clear)
Yes
0.62
0.26
N
20.0 ft2
11 ft 0 in
3 ft 0 in
None
None
7
e
3
Metal
Double (Clear)
Yes
0.62
0.26
N
11.7 ft2
2 ft 0 in
1 ft 0 in
None
None
8
e
3
Metal
Double (Clear)
Yes
0.62
0.26
N
6.5 ft2
2 ft 0 in
1 ft 0 in
None
None
9
e
3
Metal
Double (Clear)
Yes
0.62
0.26
N
20.0 ft2
30 ft 0 in
3 ft 0 in
None
None
10
se
4
Metal
Double (Clear)
Yes
0.62
0.26
N
12.3 ft2
5 ft 0 in
4 ft 6 in
None
None
11
S
5
Metal
Double (Clear)
Yes
0.62
0.26
N
18.0 ft2
8 ft 0 in
0 ft 6 in
None
None
12
s
5
Metal
Double (Clear)
Yes
0.62
0.26
N
21.7 ft2
2 ft 0 in
4 ft 4 in
None
None
13
s
5
Metal
Double (Clear)
Yes
0.62
0.26
N
36.0 f12
2 ft 0 in
1 ft 0 in
None
None
14
w
6
Metal
Double (Clear)
Yes
0.62
0.26
N
9.0 ft2
2 ft 0 in
1 ft 0 in
None
None
15
w
6
Metal
Double (Clear)
Yes
0.62
0.26
N
43.3 ft2
2 ft 0 in
1 ft 0 in
None
None
16
W
6
Metal
Double (Clear)
Yes
0.62
0.26
N
20.0 ft2
30 ft 0 in
3 ft0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
689 ft2
689 ft2
64 ft
9.3 ft
1
10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000454
2864.3 157.25 , 295.73 .1733
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1 29.48 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 16 47 kBtu/hr cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Main
0.94 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM ,
FSEC
Cert # Company Name
Collector
System Mode[ # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
-- Supply --
# Location R-Value Area
-- Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 648 ft2
Attic
312 ft2 Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
HeatinHJan HFeb Pq Mar
Ventin Jan Feb X Mar
Ceiling Fans:
Apr Ma X Jun X Jul [X] Aug Se [
E Apr I May f Jun f Jul [ j Auf Sep [ ]
[X] A r May [ Jun [ Jul [ ] Aug [ Se [X]
Oct Nov
Oct Nov
Oct X Nov
Dec
Dec
Dec
10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ftz
0 ft
0.3
Main
10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
47.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2407
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.620
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.260
14. Heating system: Capacity
29.5
c) Area
7c. 434.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood .frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9b.
15. Water heating system
9c.
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
10A1.
e) Dedicated heat pump with tank EF
10A2. 4.1
f) Heat recovery unit HeatRec%
g) Other
101311. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 40.0
b) Cross ventilation No
11b.
c) Whole house fan No
11 c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has coi
saving features which will be i
display card will be completed
Builder Signature:.
with the Florida Building Code, Energy Conservation, through the above energy
d (or exceeded) in this home before final inspection. Otherwise, a new EPL
I on installed code compliant features.
Date: /O r( /o)(:) (='*�0
Address of New Home: 9614 KNOLLWOOD LN City/FL Zip: FORT PIERCE, FL 34951
10/1/2020 1:43:02 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Load Short Form Job:
W rJ htsoft Date: Sep 29, 2020
Entire House By:
Project Information
For: MW-49
9614 KNOLLWOOD LN, FORT PIERCE, FL 34951
Htg Clg Infiltration
Outside db (°F) 43 90 Method Simplified
Inside db (°F) 70 72 Construction quality Tight
Design TD (°F) 27 18 Fireplaces 0
Daily range - L
Inside humidity (%) 30 50
Moisture difference (gr/lb) 0 68
HEATING EQUIPMENT
COOLING EQUIPMENT
' Make
Make Lennox
Trade
Trade ML14XC1 SERIES
Model
Cond ML14XC1-047-230A-.
AHRI ref
Coil CBA27UHE-048-230.+TDR
AHRI ref 10259428
Efficiency
100 EFF
Efficiency 13.0 EER, 16 SEER
Heating input
8.6
kW
Sensible cooling 32900
Btuh
Heating output
29480
Btuh
Latent cooling 14100
Btuh
Temperature rise
17
°F
Total cooling 47000
Btuh
Actual air flow
1550
cfm
Actual air flow 1550
cfm
Air flow factor
0.048
cfm/Btuh
Air flow factor 0.046
cfm/Btuh
Static pressure
0
in H2O
Static pressure 0
in H2O
Space thermostat
Load sensible heat ratio 0.70
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
370
5784
5186
278
240
HER WIC
87
1238
733
59
34
HIS WIC
44
38
229
2
11
GREAT ROOM
506
5520
5958
265
276
DINING
187
2905
2401
140
111
FOYER
75
1433
1018
69
47
NOOK
139
2551
2646
123
123
KIT
164
140
1622
7
75
BED 3
149
1589
3115
76
144
BED3WIC
33
1058
621
51
29
CABANA
76
2084
1265
100
59
BED 2
188
1830
3239
88
150
BATH 2
59
1025
1122
49
52
UTILITY
49
107
695
5
32
MECH
36
457
632
22
29
h AA QTCO t3A-rU
nAA
AAn4
nnCA
nIgn
4n7
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-01 13:11:16
�*� WrightsOf#' Right -Suite® Universal 2012 12.1.05 RSU02818 Page 1
1+M C:\Users\Jason\Documents\Wrightsoft HVAC\MW-49.rup Calc = MJ8 Front Door faces: S
Entire House
2406
32248
33435
1550
1550
Other equip loads
0
0
Equip. @ 0.95 RSM
31764
Latent cooling
14200
Tf1TA1 �+
I 7AAC
I 'JnnA0
I ACnnO
I 4rr-n
I ACClA
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Oct-01 13:11:16
wrightsoft' Right -Suite® Universal201212.1.05RSU02818 Paget
+�► C:\UserslJasonlDocuments\Wrightsoft HVAC\MW-49.rup Calc = MJ8 Front Door faces: S
->- wrightsoftt Project Summary
Entire House
Job:
Date: Sep 29, 2020
By:
Project Information
For: MW-49
9614 KNOLLWOOD LN, FORT PIERCE, FL 34951
Notes:
Design Information
Weather: Vero Beach, FL, US
Winter Design Conditions
Outside db
43
OF
Inside db
70
OF
Design TD
27
OF
Heating Summary
Structure
26491
Btuh
Ducts
5757
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
32248
Btuh
Method
Construction quality
Fireplaces
Infiltration
Simplified
Tight
0
Heating Cooling
Area (ft2)
2406
2406
Volume (ft3)
24593
24593
Air changes/hour
0.11
0.06
Equiv. AVF (cfm)
45
25
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.6 kW
29480 Btuh
17 OF
1550 cfm
0.048 cfm/Btuh
0 in H2O
Summer Design Conditions
Outside db
90
OF
Inside db
72
OF
Design TD
18
OF
Daily range
L
Relative humidity
50
%
Moisture difference
68
gr/lb
Sensible Cooling Equipment Load Sizing
Structure 26319 Btuh
Ducts 7116 Btuh
Central vent (0 cfm) 0 Btuh
Blower 0 Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 31764 Btuh
Latent Cooling Equipment Load Sizing
Structure
11884
Btuh
Ducts
2315
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
14200
Btuh
Equipment total load
45963
Btuh
Req. total capacity at 0.70 SHR
3.8
ton
Cooling Equipment
Summary
Make Lennox
Trade ML14XC1 SERIES
Cond ML14XC1-047-230A-.
Coil CBA27UHE-048-230.+TDR
AHRI ref 10259428
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
13.0 EER, 16 SEER
32900
Btuh
14100
Btuh
47000
Btuh
1550
cfm
0.046
cfm/Btuh
0
in H2O
0.70
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
•. W1'il hfisoft" 2020-Oct-0113:1L16
Right -Suite® Universal 2012 12.1.05 RSU02818 Page 1
C:\Users\Jason\Documents\Wrightsoft 1-1VAC\MW-49.rup Calc = MJ8 Front Door faces: S
III
616
BANA 59 CFM
COVERED
�J
LANAI
NOOK
12"x12"
BEDROOM 3
R.A.G.
W/ 8"0
10x10x7
FLEX
145 CFM
10 x 10x 7
Y0
123 CFM
TO
7'0
GREAT ROOM
x8x6
O
75 CFM
T-STAT SHALL BE WITHIN 3 FEET
X It
KIT
HORIZONTALLY OF MAIN RETURN
10x10x7
149 CFM
BEDROOM 2 A
ATH 2
6x6x5
52 CFM
4-TON C
4-TON 669
�l BxBx
29 CFI
ME
au . mur
r u.
cU-1
4-TON
A2 CAR GARAGE
276 CFMx 9
MASTER
SUITE
12x12x9
169A6" 240CFM
W/ 12"0 hmt 9'0
f
, I,
■III!�Ilf
i_==�
■':.47
CFM—
I
_
J'
1
FOYER
Mn:.
:noI
50 CFM
EXHAUST
�
�oluuunwlmumm�
�nuc .�
nilu�nu�o�
`ouuli
GHO HOME5
MW-49
9614 KNOLLWOOD LN
FORT FIEKCE, FL 34951
00 NOT SCALE PLANS