Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-49 Builder Name: GHO BUILDERS Street: 9614 KNOLLWOOD LN Permit Office: ST. LUCIE COUNTYLNOV12020 City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: nty, permitting Design Location: FL, Fort Pierce County: St. Lucie (Florida Clim 1. New construction or existing New (From Plans) 9. Wall Types (2473.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2163.40 ftZ b. Frame - Wood, Adjacent R=11.0 309.78 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 3 d. N/A R= ftZ 5. 'is this a worst case? No 10. Ceiling Types (2407.0 sgft.) Insulation Area a. Under Attic (Vented) R=40.0 2407.00 ftZ 6. Conditioned floor area above grade (ftZ) 2407 b. N/A R= ftZ Conditioned floor area below grade (ftZ) 0 c. R= ftZ 11. Ducts R ftZ 7. Windows(434.5 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 648 a. U-Factor: Dbl, U=0.62 434.49 ftZ SHGC: SHGC=0.26 b. U-Factor: N/A ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 47.0 SEER:16.00 ' c. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a. Electric Strip Heat 29.5 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 8.958 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2407.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2407.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 15. Credits Pstat Glass/Floor Area: 0.181 Total Proposed Modified Loads: 77.32 PASS Total Baseline Loads: 81.63 I hereby certify that the plans and specifications covered by Review of the plans and tuE ST.gT this calculation are in compliance with the Florida Energy specifications covered by this ti� = s 0,�, Code. calculation indicates compliance cyii' `O with the Florida Energy Code. nNrs911 'n :::.•;:"��,ti PREPARED BY: Before construction is completed DATE: 10/1/2020 this building will be inspected for compliance with Section 553.908 � * "� I hereby certify that this building, as designed, is in compliance Florida Statutes. l �� with the Florida Energy Code. COD WE OWNER/AGEr. MA BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Gompliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-49 User 1 GHO BUILDERS ST. LUCIE COUNTY Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2407 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 9614 KNOLLWOOD LN County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 2407 24551.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2407 24551.4 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 217.9 ft 0 2407 ft2 ---- 0 0 1 ROOF V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 2692 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2407 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 2407 ft2 0.1 Wood 10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHFCKI _IST RFPnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ornt To Wall Type R-Value Ft In EtInArea R-Value-Fraction-AAbsor.-Gradeo- 1 N Exterior Concrete Block - Ext Insul Main 4.1 63 2 9 4 589.6 f12 0 0 0.3 0 2 NE Exterior Concrete Block - Ext Insul Main 4.1 8 7 11 4 97.3 ft2 0 0 0.3 0 _ 3 E Exterior Concrete Block - Ext Insul Main 4.1 55 9 9 4 520.3 ft2 0 0 0.3 0 4 SE Exterior Concrete Block - Ext Insul Main 4.1 2 11 11 4 33.1 ft2 0 0 0.3 0 5 S Exterior Concrete Block - Ext Insul Main 4.1 36 2 11 4 409.9 ft2 0 0 0.3 0 6 W Exterior Concrete Block - Ext Insul Main 4.1 55 0 9 4 513.3 ft2 0 0 0.3 0 7 - Garage Frame - Wood Main 11 27 4 11 4 309.8 ft2 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main None .39 6 2 12 ft2 WINDOWS, Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft2 2 ft 0 in 3 ft 0 in None None • 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft2 2 ft 0 in 3 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 31.6 ft2 6 ft 0 in 1 ft 0 in None None 4 n 1 Metal Double (Clear) Yes 0.62 0.26 N 111.6 ft2 14 ft 0 in 1 ft 0 in None None 5 ne 2 Metal Double (Clear) Yes 0.62 0.26 N 22.5 ft2 7 ft 0 in 1 ft 0 in None None 6 ne 2 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft2 11 ft 0 in 3 ft 0 in None None 7 e 3 Metal Double (Clear) Yes 0.62 0.26 N 11.7 ft2 2 ft 0 in 1 ft 0 in None None 8 e 3 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft2 2 ft 0 in 1 ft 0 in None None 9 e 3 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft2 30 ft 0 in 3 ft 0 in None None 10 se 4 Metal Double (Clear) Yes 0.62 0.26 N 12.3 ft2 5 ft 0 in 4 ft 6 in None None 11 S 5 Metal Double (Clear) Yes 0.62 0.26 N 18.0 ft2 8 ft 0 in 0 ft 6 in None None 12 s 5 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 2 ft 0 in 4 ft 4 in None None 13 s 5 Metal Double (Clear) Yes 0.62 0.26 N 36.0 f12 2 ft 0 in 1 ft 0 in None None 14 w 6 Metal Double (Clear) Yes 0.62 0.26 N 9.0 ft2 2 ft 0 in 1 ft 0 in None None 15 w 6 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft2 2 ft 0 in 1 ft 0 in None None 16 W 6 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft2 30 ft 0 in 3 ft0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 689 ft2 689 ft2 64 ft 9.3 ft 1 10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000454 2864.3 157.25 , 295.73 .1733 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 29.48 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 16 47 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM , FSEC Cert # Company Name Collector System Mode[ # Collector Model # Area Storage Volume FEF None None ft2 DUCTS -- Supply -- # Location R-Value Area -- Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 648 ft2 Attic 312 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingJan Feb Mar HeatinHJan HFeb Pq Mar Ventin Jan Feb X Mar Ceiling Fans: Apr Ma X Jun X Jul [X] Aug Se [ E Apr I May f Jun f Jul [ j Auf Sep [ ] [X] A r May [ Jun [ Jul [ ] Aug [ Se [X] Oct Nov Oct Nov Oct X Nov Dec Dec Dec 10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 10/1/2020 1:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 47.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2407 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 29.5 c) Area 7c. 434.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood .frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9b. 15. Water heating system 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF 10A1. e) Dedicated heat pump with tank EF 10A2. 4.1 f) Heat recovery unit HeatRec% g) Other 101311. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 40.0 b) Cross ventilation No 11b. c) Whole house fan No 11 c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has coi saving features which will be i display card will be completed Builder Signature:. with the Florida Building Code, Energy Conservation, through the above energy d (or exceeded) in this home before final inspection. Otherwise, a new EPL I on installed code compliant features. Date: /O r( /o)(:) (='*�0 Address of New Home: 9614 KNOLLWOOD LN City/FL Zip: FORT PIERCE, FL 34951 10/1/2020 1:43:02 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Load Short Form Job: W rJ htsoft Date: Sep 29, 2020 Entire House By: Project Information For: MW-49 9614 KNOLLWOOD LN, FORT PIERCE, FL 34951 Htg Clg Infiltration Outside db (°F) 43 90 Method Simplified Inside db (°F) 70 72 Construction quality Tight Design TD (°F) 27 18 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 68 HEATING EQUIPMENT COOLING EQUIPMENT ' Make Make Lennox Trade Trade ML14XC1 SERIES Model Cond ML14XC1-047-230A-. AHRI ref Coil CBA27UHE-048-230.+TDR AHRI ref 10259428 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.6 kW Sensible cooling 32900 Btuh Heating output 29480 Btuh Latent cooling 14100 Btuh Temperature rise 17 °F Total cooling 47000 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.70 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 370 5784 5186 278 240 HER WIC 87 1238 733 59 34 HIS WIC 44 38 229 2 11 GREAT ROOM 506 5520 5958 265 276 DINING 187 2905 2401 140 111 FOYER 75 1433 1018 69 47 NOOK 139 2551 2646 123 123 KIT 164 140 1622 7 75 BED 3 149 1589 3115 76 144 BED3WIC 33 1058 621 51 29 CABANA 76 2084 1265 100 59 BED 2 188 1830 3239 88 150 BATH 2 59 1025 1122 49 52 UTILITY 49 107 695 5 32 MECH 36 457 632 22 29 h AA QTCO t3A-rU nAA AAn4 nnCA nIgn 4n7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-01 13:11:16 �*� WrightsOf#' Right -Suite® Universal 2012 12.1.05 RSU02818 Page 1 1+M C:\Users\Jason\Documents\Wrightsoft HVAC\MW-49.rup Calc = MJ8 Front Door faces: S Entire House 2406 32248 33435 1550 1550 Other equip loads 0 0 Equip. @ 0.95 RSM 31764 Latent cooling 14200 Tf1TA1 �+ I 7AAC I 'JnnA0 I ACnnO I 4rr-n I ACClA Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-01 13:11:16 wrightsoft' Right -Suite® Universal201212.1.05RSU02818 Paget +�► C:\UserslJasonlDocuments\Wrightsoft HVAC\MW-49.rup Calc = MJ8 Front Door faces: S ->- wrightsoftt Project Summary Entire House Job: Date: Sep 29, 2020 By: Project Information For: MW-49 9614 KNOLLWOOD LN, FORT PIERCE, FL 34951 Notes: Design Information Weather: Vero Beach, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 26491 Btuh Ducts 5757 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 32248 Btuh Method Construction quality Fireplaces Infiltration Simplified Tight 0 Heating Cooling Area (ft2) 2406 2406 Volume (ft3) 24593 24593 Air changes/hour 0.11 0.06 Equiv. AVF (cfm) 45 25 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.6 kW 29480 Btuh 17 OF 1550 cfm 0.048 cfm/Btuh 0 in H2O Summer Design Conditions Outside db 90 OF Inside db 72 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 68 gr/lb Sensible Cooling Equipment Load Sizing Structure 26319 Btuh Ducts 7116 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 31764 Btuh Latent Cooling Equipment Load Sizing Structure 11884 Btuh Ducts 2315 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 14200 Btuh Equipment total load 45963 Btuh Req. total capacity at 0.70 SHR 3.8 ton Cooling Equipment Summary Make Lennox Trade ML14XC1 SERIES Cond ML14XC1-047-230A-. Coil CBA27UHE-048-230.+TDR AHRI ref 10259428 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.0 EER, 16 SEER 32900 Btuh 14100 Btuh 47000 Btuh 1550 cfm 0.046 cfm/Btuh 0 in H2O 0.70 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. •. W1'il hfisoft" 2020-Oct-0113:1L16 Right -Suite® Universal 2012 12.1.05 RSU02818 Page 1 C:\Users\Jason\Documents\Wrightsoft 1-1VAC\MW-49.rup Calc = MJ8 Front Door faces: S III 616 BANA 59 CFM COVERED �J LANAI NOOK 12"x12" BEDROOM 3 R.A.G. W/ 8"0 10x10x7 FLEX 145 CFM 10 x 10x 7 Y0 123 CFM TO 7'0 GREAT ROOM x8x6 O 75 CFM T-STAT SHALL BE WITHIN 3 FEET X It KIT HORIZONTALLY OF MAIN RETURN 10x10x7 149 CFM BEDROOM 2 A ATH 2 6x6x5 52 CFM 4-TON C 4-TON 669 �l BxBx 29 CFI ME au . mur r u. cU-1 4-TON A2 CAR GARAGE 276 CFMx 9 MASTER SUITE 12x12x9 169A6" 240CFM W/ 12"0 hmt 9'0 f , I, ■III!�Ilf i_==� ■':.47 CFM— I _ J' 1 FOYER Mn:. :noI 50 CFM EXHAUST � �oluuunwlmumm� �nuc .� nilu�nu�o� `ouuli GHO HOME5 MW-49 9614 KNOLLWOOD LN FORT FIEKCE, FL 34951 00 NOT SCALE PLANS