HomeMy WebLinkAbout2011-0330 Engineer ReportMENGINEERING 84485 144207-3320717593 1 Page 1/4
Date: January 11th, 2021
ASCE 7 Components & Cladding Wall Pressure Calculator
Prepared For:
6710 Benjamin Rd. #200
Tampa FL
Project: Snyder
Project Address:
9650 S ocean drive 2009
Jensen Florida
NOTE: Thls tilgltally sealed filets being provkled In an
unlccked format at the building departments request.
Please review any changes/markups to ensure integrity
of the source document to prevent fraud.
Digitally signed
by Frank
Bennardo
Date: 2021.01.11
12:00:37-05'00'
Frank Bennardo, PE FL46549 or Richard Neet, PE FL8fi488
The following has been
considered in determining allowable stress
design
(ASD) wall opening pressures for the
referenced location.
location.
ASCE: ASCE 7-10 (6TH EDN FLORIDA BUILDING CODE, 2017 FBC,
20151BC)
Wind Velocity: 170 MPH
Exposure Category: D
Kd: 0.85
Kzt: 1
Elevation Above Sea Level: 0 FT
Minimum Building Dimension: 170FT
Mean Roof Height: 189FT
Unit Elevation: 170FT
ROOF SLOPE: FLAT (<100)
Number Of Openings: 5
Shutter: YES
Mark: 1
Height Of Opening: 62 IN
Width Of Opening: 52 IN
Zone: 4
Mark: 2
Height Of Opening: 62 IN
Width Of Opening: 72 IN
Zone: 4
Mark: 3
Height Of Opening: 96 IN
Width Of Opening: 142 IN
Zone: 4
Mark: 4
Height Of Opening: 96 IN
Width Of Opening: 70 IN
Zone:4
Mark: 5
Height Of Opening: 96 IN
Width Of Opening: 142 IN
Zone: 4
Based on the above, the following ASD design pressures apply far the
a
C) 5 ;at 5 5 J .
ram pLEVgT10N
Bul
faf
LEASTNON.iONNTPI...)
DIMEN I
Part
IRIGHT
s a
PUtN VIEW .
-rirni,ue
COMPLEX \
CORNERS
5„5,
r.urT.,o.oamoeasou,wm aT„aT oeoM/3' ..00�,Te.oa.
Corp, Office: 160 SW 12[h Avenue Suite 106, Dee�eld Beach, Florida 33442
(954) 354-0660 (8fifi) 396-9999 Team@EngineeringExpress.com EngineeringExpress.com
ENGINEERING 84485 1 44207-3320717593 1 Page 2/4
1::- 'ti`a r[ J!i . d ,� i ;'
c._ 3
opening marks which shall correspond with contractor -supplied building
ayout:
a: 17 FT
Mark: 1
Wall Positve Pressure: 633PSF
Wall Negative Pressure: -65PSF
Mark: 2
Wall Positve Pressure: 61.9PSF
Wall Negative Pressure:-63.8PSF
Mark: 3
Wall Positve Pressure: 55.7PSF
Wall Negative Pressure:-59.7PSF
Mark: 4
Wall Positve Pressure: 59.6PSF
Wall Negative Pressure:-62.3PSF
Mark: 5
Walt Positve Pressure: 55.7PSF
Wall Negative Pressure:-59.7PSF
Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only
(Gcpi=+-0.18). Results are based on contractor -supplied data and are not field verified by this office. Input shall be verified
by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be
within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a
licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your
openings, visit Engineering Express.com/Wind.