HomeMy WebLinkAbout2011-0330 Engineer ReportMENGINEERING 84485 144207-3320717593 1 Page 1/4 Date: January 11th, 2021 ASCE 7 Components & Cladding Wall Pressure Calculator Prepared For: 6710 Benjamin Rd. #200 Tampa FL Project: Snyder Project Address: 9650 S ocean drive 2009 Jensen Florida NOTE: Thls tilgltally sealed filets being provkled In an unlccked format at the building departments request. Please review any changes/markups to ensure integrity of the source document to prevent fraud. Digitally signed by Frank Bennardo Date: 2021.01.11 12:00:37-05'00' Frank Bennardo, PE FL46549 or Richard Neet, PE FL8fi488 The following has been considered in determining allowable stress design (ASD) wall opening pressures for the referenced location. location. ASCE: ASCE 7-10 (6TH EDN FLORIDA BUILDING CODE, 2017 FBC, 20151BC) Wind Velocity: 170 MPH Exposure Category: D Kd: 0.85 Kzt: 1 Elevation Above Sea Level: 0 FT Minimum Building Dimension: 170FT Mean Roof Height: 189FT Unit Elevation: 170FT ROOF SLOPE: FLAT (<100) Number Of Openings: 5 Shutter: YES Mark: 1 Height Of Opening: 62 IN Width Of Opening: 52 IN Zone: 4 Mark: 2 Height Of Opening: 62 IN Width Of Opening: 72 IN Zone: 4 Mark: 3 Height Of Opening: 96 IN Width Of Opening: 142 IN Zone: 4 Mark: 4 Height Of Opening: 96 IN Width Of Opening: 70 IN Zone:4 Mark: 5 Height Of Opening: 96 IN Width Of Opening: 142 IN Zone: 4 Based on the above, the following ASD design pressures apply far the a C) 5 ;at 5 5 J . ram pLEVgT10N Bul faf LEASTNON.iONNTPI...) DIMEN I Part IRIGHT s a PUtN VIEW . -rirni,ue COMPLEX \ CORNERS 5„5, r.urT.,o.oamoeasou,wm aT„aT oeoM/3' ..00�,Te.oa. Corp, Office: 160 SW 12[h Avenue Suite 106, Dee�eld Beach, Florida 33442 (954) 354-0660 (8fifi) 396-9999 Team@EngineeringExpress.com EngineeringExpress.com ENGINEERING 84485 1 44207-3320717593 1 Page 2/4 1::- 'ti`a r[ J!i . d ,� i ;' c._ 3 opening marks which shall correspond with contractor -supplied building ayout: a: 17 FT Mark: 1 Wall Positve Pressure: 633PSF Wall Negative Pressure: -65PSF Mark: 2 Wall Positve Pressure: 61.9PSF Wall Negative Pressure:-63.8PSF Mark: 3 Wall Positve Pressure: 55.7PSF Wall Negative Pressure:-59.7PSF Mark: 4 Wall Positve Pressure: 59.6PSF Wall Negative Pressure:-62.3PSF Mark: 5 Walt Positve Pressure: 55.7PSF Wall Negative Pressure:-59.7PSF Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only (Gcpi=+-0.18). Results are based on contractor -supplied data and are not field verified by this office. Input shall be verified by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your openings, visit Engineering Express.com/Wind.