HomeMy WebLinkAboutProduct Approval 1/4/2021 Florida Building Code Online
Fist•- _ �£ r!'.y�.
ISCIS Home i Log In I user Registration Hot Topics i Submit Surcharge Stats&Facts Publications Contact C Si s-Mam•',Links I Search
Florida �, 1 q
.:"ol
Product Approval USER:Public User
p r _pp ava Mmn{>P+mdurt or Apnlleation Search>All 11cat n Lis >Application Detail
FL FL389-R10 E Y Y D
Application Type Revision
Code Version 2020 CODE COMPLIANCE
Application Status Approved S'T. LGocc CIE COUN Y
Comments h, /�
Archived
Product Manufacturer American Shutter Systems Association,Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach,FL 33407
(561)209-8263
bfeeley@eastemmetal.com
Authorized Signature Bill Feeley
Irod rig uez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A..Tlllit,Jr. P.E.
Evaluation Report
Florida License PE-44167
Quality Assurance Entity CNa/* nalAccreditation and Management Institute
Quality Assurance Contract Expiration Date /2021
Validated By enry Kampmann Jr.
Validation Checklist-Hardcopy Received
Certificate of Independence FUM Rio COI COY ASSA BLADE-1 hSlf
FLs$ R10 COI COI ASSA BLADF'I 2 p.
FI.349 RIO COI COI ASSA BLADC3 Qf
Referenced Standard and Year(of Standard) Standard YAPT
ASTM E-1886 2012
` ASTM E-1996 2012
+4 ! ASTM E-330 2002
(( TAS 201,202,203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
1141LULI Florida Building Code Online
Product Approval Method Method 1 Option D
• Date Submitted 10/15/2020
Date Validated 11/06/2020
Date Pending FBC Approval 11/06/2020
Date Approved 12/15/2020
Summa of Products
FL# Model,Number or Name Description
389.1 Bertha HV Accordion Shutter-Blade Extruded aluminum interlocking blades retained by tracks(top
3-(Non-HVHZ)-Drwg 20-165 and bottom)for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ:No Fi_389 RID 1I QRWING ASSA BLADE3.p ff
Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida,Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Large Missile Level"D".Max span is 12'-3"for 40 psf FL389 RIO AE PER ASSA BLADE3.pdf
positive ASD load and 13'-0"for 35 psf negative ASD load the Created by Independent Third Party:Yes
HV3 blade w/o window blade,5'-2"for 110 psf ASD load for
HV3 blade w/o window blade and W-11"for 62 psf,9'-11"for
55 psf HV3 blade w/window blade working in unison.Max.span
for HV3 blade w/o window blade for Installations into Metal
Stud walls is 79"for max.ASD pressure rating of+72,72 and
84"for+64,-64 psf.See sheet 5 for other spans and ASD
pressures. - _.........--.__r..-.._...,__...
389.2 Bertha HV Accordion Shutter-Blade 1 Extruded aluminum Interlocking blades retained by tracks(top
Only-(Non-HVHZ)-Drwg 20-164 and bottom)for storm protection S
Limits of Use Installation Instructions `1
Approved for use in HVHZ:No FL389 R10 IT DRWING ASSA BLADE1.pdf 1
Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida,Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Large missile level"D". Max.Span is 16'-0"for 30 p.s.f FL389 R10 AE PER ASSA BLADEi..pdf
negative ASD load depending on centermates and locking rod Created by Independent Third Party:Yes
! configuration for the HV1 blade,8'-0"for+64,-72 p.s.f.A.S.D.
load for HV blade for Keystone mountings 7-0"p.s.f.for metals
stud mountings and 8'-0"for 110 p.s.f.for HV1A working in
unison.See sheets 7, 11 and 20 respectively of installation
drawings for other spans and pressures.
389.3 Bertha HV Accordion Shutter- Extruded aluminum Interlocking blades retained by tracks(top
COMBO-(Non-HVHZ)-Drwg 20-163 and bottom)for storm protection
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL389 RIO II PRW AS5g,t3LADEI -pdf
Approved for use outside HVHZ:Yes Verified By:American Test Lab of South Florida,Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Large missile. Max. 16'-0"span at 30 p.s.f ASD load FL389 RIO AE PER ASSA BLADE1 2,pdf
for Blade 1 and 18'-0"for Blade 2.See schedules on sheet 12, Created by Independent Third Party:Yes
25 and 28 respectively
0 lJ
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA!EEO employer.Copyljaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click e e.
Product Approval Accepts:
WHIM FOR ER EMd
r Credit Card
Safe
www.floridabuilding.org/pr/pr app_ U.aspx?param=wGEVXQwtDgvYYHH2vJvx63MwsXdCOtOXPGxaL8B7Zzg%3d 7/�