Loading...
HomeMy WebLinkAboutEnergy CodeFARM R405-2017 FIILORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Bemiett Residence Builder Name: Street: XXX Avenue S Penrit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34947 Pen -nit Number: Owner: Cheiyl & Johhny Bennett Jurisdiction: St. Lucie County Design Location: FL, 1-ort Pierce County: St. Lucie (Floridan Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2407.9 sqft.) Insulation Area 2. Single family or multiple; family Single-family a.. Concrete Block - Int Insul, E•:xterior R=5.4 2099.90 ft2 b. Frame - Wood, Adjacent R=11.0 308.00 ft2 3. Number of units, if multiple family 1 c:. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2672.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2672.00 ft2 6. Conditioned floor area above grade (ft2) 2672 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(248.0 sgft.) Description Area a.. Sup: Attic, Ret: Attic, AH: AHU 6 105 a. U-Factor: Sgl, U=0.65 248.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a„ Central Unit 41.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00- SHGC: Area Weighted Average Overhang Depth: 5.637 ft. Area Weighted Average SHGC; 0.250 14. Hot water systems 8. Floor Types (2672.0 sgft.) Insulation Area a.. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2672.00 ft2 b. Conservation features EF: 0.950 b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Total Proposed Modified Loads: 78.36 Glass/Floor Area: 0.093 PASS Total Baseline Loads: 78.67 I hereby certify that the plans and specifications covered by Review of the plans and RVE SZA this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance ,y = �p with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 7-30-20 this building will be inspected for compliance with Section 553,908 �I I hereby certify that this building, as designed, is in compliance Floricla Statutes. with the Florida Energy Code. COD'S OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R4102.4.1.1 and this project: requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2). FILE COP�( 7/29/2020 1:05 PM EnergyGaugeO USA 6.0,02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Flags 1 of 7 FORM R405-2017 INPUT SUMMARY CHFCKLIIST RFPf)RT PROJECT Title: Bennett Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2672 Lot Al Owner Name: Cheryl & Johhny Bennett Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: XXX Avenue S Permit Office: St, Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lurie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single family FL, 34947 New/Existing: New (from Plans) Comment: CLIMATE / Design Temp Int Design Terrip Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Plerre FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Nume Area Volume 1 Entire House 2672 25116.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master :suite 321 3017.4 No 2 1 1 Yes Yes Yes 2 M Bath 144 1353.6 No 1 I Yes Yes Yes 3 Toilet 24 225.6 No 0 1 Yes Yes Yes 4 M WIC 133 1250.2 No 0 1 No Yes Yes 5 Hall 23 216.2 No 0 1 Yes Yes Yes 6 WIC 3 42 394.8 No 0 1 Yes Yes Yes 7 Bath 3 72 676.8 No 0 11 No Yes Yes 8 AHU 24 225.6 No 0 1 No Yes Yes 9 Bedroom 3 174 1635.6 No 1 1 1 Yes Yes Yes 10 Laundry 72 676.8 No 1 I No Yes Yes 11 Hall 44 413.6 No 0 1 No Yes Yes 12 Den 169 1588.6 No 2 I Yes Yes Yes 13 Foyer 112 1052.8 No 0 1 Yes Yes Yes 14 Great Room 450 4230 No 2 1 Yes Yes Yes 15 Dining 208 1955.2 No 2 •1 Yes Yes Yes 16 Kitchen 316 2970.4 Yes 2 1 Yes Yes Yes 17 Pantry 20 188 No 0 1 Yes Yes Yes 18 Bath 2 60 564 No 0 1 Yes Yes Yes 19 WIC 2 30 282 No 0 1 No Yes Yes 20 Hall 18 169.2 No 0 1 No Yes Yes 21 Bedroom 2 216 2030.4 No 2 1 1 Yes Yes Yes 7/29/2020 1:05 PM EnergyGaugeO USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Woad Carpet 1 Slab -On -Grade Edge Insulatio Master Suite 51 ft 321 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulatio M Bath 11 ft 144 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio Toilet 3ft 24 ft2 ---- 1 0 0 4SIab-On-Grade Edge Insulatio M VVIC 1 ft 133 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulatio Hall 1 3 ft 23 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulatio WIC 3 6 ft 42 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulatio Bath 3 1 ft 72 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio AHU 1 ft 24 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 3 13 ft 174 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Laundry 1 ft 72 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio Hall 2 1 ft 44 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio Den 6 ft 169 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulatio Foyer 9 ft 112 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulatio Great Room 18 ft 450 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulatio Dining 38 ft 208 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulatio Kitchen 17 ft 316 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulatio Pantry 4 ft 20 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulatio Bath 2 loft 60 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulatio WIC 2 1 ft 30 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulatio Hall 3 1 ft 18 ft2 ---- 1 0 0 21SIab-On-Grade Edge Insulatio Bedroom 2 34 ft 216 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2988 ft2 0 ft2 Medium N 0.6 No 0.9 No 20 26.6 ATTIC / ' V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2672 ft2 N N 7/29/2020 1:05 PM EnergyGaugeO USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Master Suite 0 Blown 321 ft2 0.1 Wood 2 Under Attic (Unvented) M Bath 0 Blown 144 ft2 0.1 Wood 3 Under Attic (Unvented) Toilet 0 Blown 24 ft2 0.1 Wood 4 Under Attic (Unvented) M WIC 0 Blown 133 ft2 0.1 Wood 5 Under Attic (Unvented) Hall 1 0 Blown 23 ft2 0.1 Wood 6 Under Attic (Unvented) WIC 3 0 Blown 42 ft2 0.1 Wood 7 Under Attic (Unvented) Bath 3 0 Blown 72 ft2 0.1 Wood 8 Under Attic (Unvented) AHU 0 Blown 24 ft2 0.1 Wood 9 Under Attic (Unvented) Bedroom 3 0 Blown 174 ft2 0.1 Wood 10 Under Attic (Unvented) Laundry 0 Blown 72 ft2 0.1 Wood 11 Under Attic (Unvented) Hall 2 0 Blown 44 ft2 0.1 Wood 12 Under Attic (Unvented) Den 0 Blown 169 ft2 0.1 Wood 13 Under Attic (Unvented) Foyer 0 Blown 112 ft2 0.1 Wood 14 Under Attic (Unvented) Great Room 0 Blown 450 ft2 0.1 Wood 15 Under Attic (Unvented) Dining 0 Blown 208 ft2 0.1 Wood 16 Under Attic (Unvented) Kitchen 0 Blown 316 ft2 0.1 Wood 17 Under Attic (Unvented) Pantry 0 Blown 20 ft2 0.1 Wood 18 Under Attic (Unvented) Bath 2 0 Blown 60 ft2 0.1 Wood 19 Under Attic (Unvented) WIC 2 0 Blown 30 ft2 0.1 Wood 20 Under Attic (Unvented) Hall 3 0 Blown 18 ft2 0.1 Wood 21 Under Attic (Unvented) Bedroom 2 0 Blown 216 ft2 0.1 Wood WALLS # ()rnt Adjacent TO S ace WaII Tipp p Cavity R,/Etue Width Et In Et Height In Arpa_ Sheathing Framing RAM]- Fraction Solar Below Absor G-de° _ 1 N Exterior Concrete Block - Int InsMaster Suite 5.4 20 0 9 5 188.3 ft" 0 0 0.4 0 - 2 E Exterior Concrete Block - Int InsLMaster Suite 5.4 15 0 9 5 141.3 ff 0 0 0.4 0 _ 3 W Exterior Concrete Block - Int InsiMaster Suite 5.4 16 0 9 5 150.7 ff 0 0 0.4 0 4 W Exterior Concrete Block - Int InSLII M Bath 5.4 11 0 9 5 103.6 ff 0 0 0.4 0 _ 5 W Exterior Concrete Block - Int Instil Toilet 5.4 3 0 9 5 28.3 ft2 0 0 0.4 0 _ 6 N Exterior Concrete Block - Int Instil Hall 1 5.4 3 0 9 5 28.3 ft2 0 0 0.4 0 7 W Exterior Concrete Block - Int Instil WIC 3 5.4 6 0 9 5 56.5 ft2 0 0 0.4 0 _ 8 W Exterior Concrete Block - Int InsuBedroom 3 5.4 13 0 9 5 122.4 ft2 0 0 0.4 0 _ 9 S Exterior Concrete Block - Int Instil Den 5.4 6 0 9 5 56.5 ft2 0 0 0.4 0 10 S Exterior Concrete Block - Int Instil Foyer 5.4 8 0 9 5 75.3 ft2 0 0 0.4 0 11 W Exterior Concrete Block - Int Instil Foyer 5.4 1 0 9 5 9.4 ft2 0 0 0.4 0 12 N Exterior Concrete Block - Int InsLGreat Room 5.4 18 0 9 5 169.5 ft' 0 0 0.4 0 13 N Exterior Concrete Block - Int Instil Dining 5.4 16 0 9 5 150.7 ff 0 0 0.4 0 _ 14 E Exterior Concrete Block - Int Instil Dining 5.4 13 0 9 5 122.4 ft2 0 0 0.4 0 _ 15 W Exterior Concrete Block - Int Insul Dining 5.4 9 0 9 5 84.8 ft2 0 0 0.4 0 16 E Exterior Concrete Block - Int Insul Kitchen 5.4 17 0 9 5 160.1 ft2 0 0 0.4 0 -17 E Exterior Concrete Block - Int Insul Pantry 5.4 4 0 9 5 37.7 ft2 0 0 0.4 0 _ 18 E Exterior Concrete Block - Int Instil Bath 2 5.4 10 0 9 5 94.2 ft2 0 0 0.4 0 _ 19 E Exterior Concrete Block - Int InsuBedroom 2 5.4 10 0 9 5 94.2 ft2 0 0 0.4 0 7/29/2020 1:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIIRT RPPf)RT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Zips p RA/aluP Ft In Ft Iq Area R-\/alua Frgntinn Ahslor GrnflP.01, _20 SE Exterior Concrete Block - Int InsuBedroom 2 5.4 5 0 9 5 47.1 ft2 0 0 0.4 0 _21 S Exterior Concrete Block - Int InsuBedroom 2 5.4 8 0 9 5 75.3 ft2 0 0 0.4 0 _22 SW Exterior Concrete Block - Int InsuBedroom 2 5.4 5 0 9 5 47.1 ft2 0 0 0.4 0 _ 23 W Exteriov Concrete Block - Int InsuBedroom 2 5.4 6 0 9 5 56.5 ft2 0 0 0.4 0 _24 N Garage Frame - Wood Bedroom 3 11 14 9 4 130.7 ft, 0.23 0.4 0 _25 N Garage Frame -Wood Laundry 11 8 9 4 74.7 ft2 0.23 0.4 0 26 N Garage Frame -Wood Den 11 7 9 4 65.3 ft2 0.23 0.4 0 _27 E Garage Frame - Wood Den 11 4 9 4 37.3 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Foyer None .39 6 6 10 41 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 2 W 4 Metal Low-E Single Yes 0.65 0.25 Y 16.0 ft2 2 ft 0 in 1 ft 4 in None None 3 W 8 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 9 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5 N 12 Metal Low-E Single Yes 0.65 0.25 Y 82.0 ft2 13 ft 0 in 1 ft 4 in None None 6 N 13 Metal Low-E Single Yes 0.65 0.25 Y 24.0 ft2 2 ft 0 in 1 ft 4 in None None 7 E 14 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 8 E 16 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 9 SE 20 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 10 S 21 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 2 ft 0 in 1 ft 4 in None None 11 SW 22 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # FIopr Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 6; 6 ft2 696 ft2 33 ft 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000299 2093.1 114.91 216.1 .1104. 5 7/29/2020 1:05 PM EnergyGauge® USA 6.0.02 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKL114T RFPC]RT HEATING SYSTEM # System 'Type Subtype Efficiency Capacity Block Ducts 1 Electric :Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype [Efficiency Capacity Air Flow SHR Block Ducts 1 Central [Jnit/ Split BEER: 16 41.5 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # Systern Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER, SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / Supply --- --- Return---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attie 6 105 ft2 Attic 25 ftz Default Leakage AHU (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: y Ceiling Fans: CoolingJan Heatin Feb Mar Jan Feb HX A r �C� Apr I un Jul May Mun I May 11 ri Aug Se ri Oct Nov HX Dec Venting Mar Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/29/2020 1:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Flags 6 of 7 FORM R405-201-20117 INPUT SUMMARY CHECKLIIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Suite Default(8 Ibs/sq.ft. ft2 ft 0.3 M Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 De%ult(8 Ibs/sq.ft, ft2 ft 0.3 Bath 3 De%ult(8 Ibs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Den Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 3 Default(8 Ibs/s .ft. ft2 ft 0.3 Bedroom 2 7/29/2020 1:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY BARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, adclition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 41.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2672 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 248.0 8, Skylights a) U-factor:(weighted average) Ba. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assemt)ly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 5.4 1061. 11.0 10132. 11 a. 0.0 11 b. 11 c. 11 d. No 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this hoMe has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection, Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Horne: XXX Avenue S City/FL Zip: Fort Pierce, FL 34947 7/29/2020 1:05:41 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1