HomeMy WebLinkAboutProduct Approval; 5V Crimp 26GA Steel Roof Panel FBCr
M c4-u ( it %tr
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th.ed.)
Compliant with Florida Product Approval Rule # 611320-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC-Sec. 1507.4.3
Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.2.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachmn,t snerifvraFinne ahn„o
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" o.c.
16" o.c.
8" O.C.
6" o.c.
FASTENER SPACING (ALONG Panel width)
12" O.C.
12" ox.
12" o.c.
12" o.c.
FASTENER SIZE 1#9
#10
#10
#10:
Reference Data:_ ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & 1897-041 Test Report EM893.01-450-18 05/02/14
- Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY--OL 1897-04 is equivalent to test standard UL 1897-1*Design pressure margin of safety 2:1
.,s�� f►rnr,..
.��` C u
Locke Bowden, P.E. does not have, not will acquire a financial in 1148160 ,",,�,,,rh an•'�+facturing or distributing products
under this evaluation. a' vtly �``Q •o '�
Locke Bowden, P.E. is not owned, operated, or controlled by air coaiparN;)rnbjddfar:turee, or distributing products under this
report. a
m-
4 COPY
''f.` TONAL ,•,i'�
} 10 FI-17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 611320-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5.-Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
15/32" or greater Plywood, or
Wood plank
24-
3!8"
OPTIONAL 3T7RINHONS
Panel Profile,
Nominal 12" Nominal 12"
O.C. O.C.
Fasten '
f9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Panel Spaced 12" o.c. across the Panel VVdth
Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
- Mod plank