Loading...
HomeMy WebLinkAboutcompactionHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # : CONTRACTOR:Horizon Pools PERMIT #:2009-0511 JOB LOCATION:7437 Bob O Link Way NUC #234 Port St Lucie, Florida Nuc Model:MC-DR Nuc Serial #:MD60308234 P.O. #: ITEM TESTED :Pool Backfill Compaction TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE PERCENT COMPACTION 1 Southeast 0'-1'50+107.8 110.9 97.2% 2 1'-2'50+-"95.0% + 3 2'-3'50+-"95.0% + 4 3'-4'50+-"95.0% + 5 West 0'-1'50+109.4 110.9 98.6% 6 1'-2'50+."95.0% + 7 2'-3'50+-"95.0% + 8 3'-4'50+-"95.0% + 9 Northeast 0'-1'50+108.3 110.9 97.7% 10 1'-2'50+-"95.0% + 11 2'-3'50+-"95.0% + 12 3'-4'50+-"95.0% + Soil Description: Dark Brown Sand In Place Moisture: 11.7% Proctor Optimum Moisture: 13.0% Proctor Max. Dry Density: P.C.F. 110.9 @ Test Locations the Density & Penetrometer reading indicate the Degree of Compaction Meets Minimum Requirement for Plumbed Backfill Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 1/13/2021 Email to: St Luice Building Department; horizonpools.sandy@gmail.com SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 January 12, 2021 Disclaimer:Contractor is responsible to maintain the pool backfill in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the poolbackfill has been altered from the approved inspected condition. Proudly Serving Florida since 1990 107.0 108.0 109.0 110.0 111.0 112.0 10 11 12 13 14 15 16 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight