Loading...
HomeMy WebLinkAboutENERGY CALCS FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BILTMORE MODEL Builder Name: Street: 105 SE CELESTIA COURT Permit Office: ST LUCIE COUNTY City, State,Zip: PORT ST LUCIE,FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (1756.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a Concrete Block-Int Insul, Exterior R=4.1 1524.00 ftz b. Frame-Wood,Adjacent R=13.0 232.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (1809.0 sqft.) Insulation Area a Under Attic(Vented) R=30.0 1809.00 ftz 6. Conditioned floor area above grade(ftz) 1809 b.N/A R= ftz c. R= ftz Conditioned floor area below grade(ftz) 0 11. Ducts R ftz 7. Windows(115.0 sqft,) Description Area a Sup:Attic,Ret:Attic,AH:AHU CLST 6 150 a U-Factor: Dbl, U=0.29 45.00 ftz SHGC: SHGC=0.29 b. U-Factor: Dbl, U=0.61 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.33 a-Central Unit 36.0 SEER:15.50 c. U-Factor: Dbi,U=0.29 30.00 ftz SHGC: SHGC=0.26 13.Heating systems kBtulhr Efficiency d. U-Factor: N/A ftz a Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.296 14.Hot water systems a Electric Cap:50 gallons 8. Floor Types (1809.0 sqft.) Insulation Area EF:0.980 a Slab-On-Grade Edge Insulation R=0.0 1809.00 ftz b. Conservation features b. N/A R= ftz None c.N/A R= ftz 15.Credits None Glass/Floor Area: 0.064 Total Proposed Modified Loads: 55.44 PASS Total Baseline Loads: 61.49 I hereby certify that the plans and specifications covered by Review of the plans and �� S TAp� this calculation are in compliance with the Florida Energy specifications covered by this v,� O� Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 12-10-210120 this building will be inspected for c-• �` compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ♦'1 � �g� with the Florida Energy Code. OD jAFF D OWNER/AGENT- - BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 12/10/2020 1:04 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BILTMORE MODEL Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1809 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 90 Street: 105 SE CELESTIA COU Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: PORT ST LUCIE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1809 17292 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M BATH 66 528 No 0 1 Yes Yes Yes 2 MASTER BEDROO 248 1984 No 0 1 1 Yes Yes Yes 3 M W IC 69 552 No 0 1 Yes Yes Yes 4 UTILITY RM 49 392 No 0 1 No Yes Yes 5 ENTRY HALL 28 224 No 0 1 No Yes Yes 6 GREAT ROOM 260 3120 No 0 1 Yes Yes Yes 7 DINING 182 2184 No 0 1 Yes Yes Yes 8 KITCHEN 263 3156 Yes 0 1 No Yes Yes 9 FOYER 54 432 No 0 1 Yes Yes Yes 10 CLST 2 18 144 No 0 1 No Yes Yes 11 BEDROOM 2 151 1208 No 0 1 1 Yes Yes Yes 12 HALL 24 192 No 0 1 No Yes Yes 13 BATH 2 55 440 No 0 1 Yes Yes Yes 14 CLST 3. 16 128 No 0 1 Yes Yes Yes 15 AHU CLST 6 48 No 0 1 No Yes Yes 16 BEDROOM 3 170 1360 No 0 1 1 Yes Yes Yes 17 BEDROOM 4 132 1056 No 0 1 1 Yes Yes Yes 18 CLST 4 18 144 No 0 1 No Yes Yes 12/10/2020 1:04 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation M BATH 17 ft 0 66 ft2 ---- 1 0 0 2 Slab-On-Grade Edge Insulation MASTER BEDRO 18 ft 0 248 ft2 ---- 1 0 0 3 Slab-On-Grade Edge Insulation M W IC 8 ft 0 69 ft2 ---- 1 0 0 4 Slab-On-Grade Edge Insulation UTILITY RM 1 ft 0 49 ft2 ---- 1 0 0 5 Slab-On-Grade Edge Insulation ENTRY HALL 1 ft 0 28 ft2 ---- 1 0 0 6 Slab-On-Grade Edge Insulation GREAT ROOM 20 ft 0 260 ft2 ---- 1 0 0 7 Slab-On-Grade Edge Insulation DINING 27 ft 0 182 ft2 ---- 1 0 0 8 Slab-On-Grade Edge Insulation KITCHEN 1 ft 0 263 ft2 ---- 1 0 0 9 Slab-On-Grade Edge Insulation FOYER 6 ft 0 54 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation CLST 2 1 ft 0 18 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation BEDROOM 2 20 ft 0 151 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation HALL 1 ft 0 24 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation BATH 2 5 ft 0 55 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation CLST 3. 2 ft 0 16 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation AHU CLST 1 ft 0 6 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation BEDROOM 3 32 ft 0 170 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulation BEDROOM 4 12 ft 0 132 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulation CLST 4 1 ft 0 18 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1959 ft2 0 ft2 Medium N 0.1 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1809 ft2 N N 12/10/2020 1:04 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) M BATH 30 Blown 66 ft2 0.1 Wood 2 Under Attic(Vented) MASTER BEDRO 30 Blown 248 ft2 0.1 Wood 3 Under Attic(Vented) M W IC 30 Blown 69 ft2 0.1 Wood 4 Under Attic(Vented) UTILITY RM 30 Blown 49 ft2 0.1 Wood 5 Under Attic(Vented) ENTRY HALL 30 Blown 28 ft2 0.1 Wood 6 Under Attic(Vented) GREAT ROOM 30 Blown 260 ft2 0.1 Wood 7 Under Attic(Vented) DINING 30 Blown 182 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 263 ft2 0.1 Wood 9 Under Attic(Vented) FOYER 30 Blown 54 ft2 0.1 Wood 10 Under Attic(Vented) CLST 2 30 Blown 18 ft2 0.1 Wood 11 Under Attic(Vented) BEDROOM 2 30 Blown 151 ft2 0.1 Wood 12 Under Attic(Vented) HALL 30 Blown 24 ft2 0.1 Wood 13 Under Attic(Vented) BATH 2 30 Blown 55 ft2 0.1 Wood 14 Under Attic(Vented) CLST 3. 30 Blown 16 ft2 0.1 Wood 15 Under Attic(Vented) AHU CLST 30 Blown 6 ft2 0.1 Wood 16 Under Attic(Vented) BEDROOM 3 30 Blown 170 ft2 0.1 Wood 17 Under Attic(Vented) BEDROOM 4 30 Blown 132 ft2 0.1 Wood 18 Under Attic(Vented) CLST 4 30 Blown 18 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo 1 N=>E Exterior Concrete Block Int Insul M BATH 4.1 6 0 8 0 48.0 ft2 0 0 0.1 0 2 W=>N Exterior Concrete Block Int Insul M BATH 4.1 11 0 8 0 88.0 ft2 0 0 0.1 0 3 N=>E Exterior Concrete Block Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.1 0 4 W=>N Exterior Concrete Block Int InsuMASTER BE 4.1 4 0 8 0 32.0 ft2 0 0 0.1 0 5 W=>N Exterior Concrete Block Int Insul M W IC 4.1 8 0 8 0 64.0 ft2 0 0 0.1 0 6 S=>W Garage Frame-Wood M W IC 13 9 0 8 0 72.0 ft2 0 0.1 0.1 0 7 S=>W Garage Frame-Wood UTILITY RM 13 7 0 8 0 56.0 ft2 0 0.1 0.1 0 8 S=>W Garage Frame-Wood ENTRY HALL 13 4 0 8 0 32.0 ft2 0 0.1 0.1 0 9 N=>E Exterior Concrete Block-Int InsuGREAT ROO 4.1 20 0 12 0 240.0 ft2 0 0 0.1 0 10 N=>E Exterior Concrete Block-Int Insul DINING 4.1 14 0 12 0 168.0 ft2 0 0 0.1 0 11 E=>S Exterior Concrete Block-Int Insul DINING 4.1 13 0 12 0 156.0 ft2 0 0 0.1 0 12 S=>W Exterior Concrete Block-Int Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.1 0 13 W=>N Garage Frame-Wood FOYER 13 9 0 8 0 72.0 ft2 0 0.1 0.1 0 14 S=>W Exterior Concrete Block-Int InsuBEDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.1 0 15 W=>N Exterior Concrete Block-Int InsuBEDROOM 2 4.1 7 0 8 0 56.0 ft2 0 0 0.1 0 16 E=>S Exterior Concrete Block-Int Insul BATH 2 4.1 5 0 8 0 40.0 ft2 0 0 0.1 0 17 E=>S Exterior Concrete Block-Int Insul CLST 3. 4.1 2 0 8 0 16.0 ft2 0 0 0.1 0 18 E=>S Exterior Concrete Block-Int InsuBEDROOM 3 4.1 12 0 8 0 96.0 ft2 0 0 0.1 0 19 S=>W Exterior Concrete Block-Int InsuBEDROOM 3 4.1 15 0 8 0 120.0 ft2 0 0 0.1 0 20 W=>N Exterior Concrete Block-Int InsuBEDROOM 3 4.1 5 0 8 0 40.0 ft2 0 0 0.1 0 21 E=>S Exterior Concrete Block-Int InsuBEDROOM 4 4.1 12 0 8 0 96.0 ft2 0 0 0.1 0 12/10/2020 1:04 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>W Insulated FOYER None .27 3 6 8 20 ft2 2 S=>W Insulated ENTRY HALL None .27 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>E 3 Vinyl Low-E Double Yes 0.29 0.29 N 15.0 ft2 1 ft 0 in 0 ft 11 in None None 2 N=>E 9 Metal Low-E Double Yes 0.61 0.33 N 40.0 ft2 1 ft 0 in 0 ft 11 in None None 3 N=>E 10 Vinyl Low-E Double Yes 0.29 0.29 N 15.0 ft2 1 ft 0 in 0 ft 11 in None None 4 S=>W 14 Vinyl Low-E Double Yes 0.29 0.26 N 15.0 ft2 1 ft 0 in 0 ft 11 in None None 5 S=>W 19 Vinyl Low-E Double Yes 0.29 0.26 N 15.0 ft2 1 ft 0 in 0 ft 11 in None None 6 E=>S 21 Vinyl Low-E Double Yes 0.29 0.29 N 15.0 ft2 1 ft 0 in 0 ft 11 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 29 ft 8 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000425 2017.4 110.75 208.29 .1582 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15.5 36 kBtu/hr 1080 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 12/10/2020 1:04 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ftz Attic 15 ftz Default Leakage AHU CLST (Default)c(Default)c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb ]Mar Apr May n Jun Jul X Aug Se Oct Nov Dec Heatin Jan Feb lX]Mar f Apr f May Jun �xl Jul 4 Aug 4 Sep Oct Nov X Dec Venting Jan Feb X Mar [X]Apr [ May Jun Jul [ Aug [ Sep [ Oct [X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 M BATH Default(8 Ibs/sq.ft. ftz ft 0.3 M TOILET Default(8 Ibs/sq.ft. ftz ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ftz ft 0.3 M W IC Default(8 Ibs/sq.ft. ftz ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ftz ft 0.3 POWDER RM Default(8 Ibs/sq.ft. ftz ft 0.3 ENTRY HALL Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ftz ft 0.3 WIC 4 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8lbs/s .ft. ftz ft 0.3 HALL 12/10/2020 1:04 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units (if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 36.0 a) Split system SEER 15.5 5, Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1809 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.401 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.296 14. Heating system: Capacity 27.0 c) Area 7c. 115.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-f actor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame(Insulation R-value) 10131. 13.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling tans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: kr Date: 12-to-Le2o Address of New Home: 105 SE CELESTIA COURT City/FL Zip: PORT ST LUCIE, FL 12/10/2020 1:05:14 PM EnergyGauge®USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.