Loading...
HomeMy WebLinkAboutMANUAL J L--r wrigni Projecty Summary Job: GARAGE LEFT Date: DEC.10,2020 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: BILTMORE MODEL, FY CONSTRUCTION 105 SE CELESTIA COURT, PORT ST LUCIE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18093 Btuh Structure 18296 Btuh Ducts 5662 Btuh Ducts 8135 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23755 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 25110 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4158 Btuh Ducts 2195 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1809 180q Equipment latent load 6352 Btuh Volume (ft3) 17292 17292 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 31462 Btuh Equiv.AVF (cfm) 110 58 Req. total capacity at 0.70 S H R 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40361-1 AHRI ref Coil TEM4AOC42S41++TDR AHRI ref 7599445 Efficiency 100 EFF Efficiency 12.5 EER, 15.5 SEER Heating input 6.0 kW Sensible cooling 25200 Btuh Heating output 20475 Btuh Latent cooling 10800 Btuh Temperature rise 16 °F Total cooling 36000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. )ft"-rk- wrigl 2020-Dec-10 12:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 1 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House M BATH 2 Exposed wall 167.0 ft 17.0 ft 3 Room height 9.6 ft 8.0 ft heat/cool 4 Room dimensions 6.0 x 11.0 ft 5 Room area 1809.0 ft2 66.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�j13A-4ocs 0.143 n 4.00 2.19 568 497 1991 1088 48 48 192 105 2 glazing,clr low-e 0.300 n 8.40 10.58 30 0 252 317 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 41 0 343 432 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 404 389 1558 851 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.19 15 2 126 438 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 272 222 887 485 0 0 0 0 I!—G� 2 glazing,clr low-e 0.300 s 8.40 10.58 30 30 252 317 0 0 0 0 D 11DO 0.390 s 10.92 10.34 20 20 223 211 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 280 280 1121 613 88 88 352 193 C 1613-30ad 0.032 0.90 1.60 1809 1809 1621 2894 66 66 59 106 F 22A-tl)h 1.358 38.02 0.00 1809 167 6350 0 66 17 646 0 6 c)AED excursion 0 -2 Envelope loss/gain 14723 7646 1250 401 12 a) Infiltration 3370 950 301 85 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 9700 250 Subtotal(lines 6 to 13) 18093 18296 1551 736 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18093 18296 1551 736 15 Duct loads 31% 44% 56621 8135 31% 44% 485 327 Total room load 23755 26431 2036 1063 Air required(cfm) 1 11200 12001 1 1 1031 48 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 1 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM M WIC 2 Exposed wall 18.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 248.0 ft 1.0 x 69.0 ft 5 Room area 248.0 ft2 69.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�j13A-4ocs 0.143 n 4.00 2.19 112 97 388 212 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 15 0 126 159 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.19 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 10.58 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 32 32 128 70 64 64 256 140 C 16B-30ad 0.032 0.90 1.60 248 248 222 397 69 69 62 110 F 22A-tl)h 1.358 38.02 0.00 248 18 684 0 69 8 304 0 6 c)AED excursion -8 -1 Envelope loss/gain 1549 829 622 249 12 a) Infiltration 318 90 142 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2300 250 Subtotal(lines 6 to 13) 1868 3219 764 539 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 10 0 0 14 Subtotal 1873 3229 764 539 15 Duct loads 31% 44% 586 1436 31% 44% 239 240 Total room load 2459 4665 1003 779 Air required(cfm) 1241 212 51 35 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 2 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name UTILITY RM ENTRY HALL 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 7.0 ft 4.0 x 7.0 ft 5 Room area 49.0 ft2 28.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.19 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!—G� 2 glazing,clr low-e 0.300 s 8.40 10.58 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 49 49 44 78 28 28 25 45 F 221%-tr)h 1.358 38.02 0.00 49 0 0 0 28 0 0 0 6 c)AED excursion -2 0 Envelope loss/gain 44 76 25 45 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 700 0 Subtotal(lines 6 to 13) 44 776 25 45 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 17 -25 -45 14 Subtotal 54 794 0 0 15 Duct loads 31% 44% 17 353 31% 44% 0 0 Total room load T70 1147 0 0 Air required(cfm) 4 52 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 3 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name GREAT ROOM DINING 2 Exposed wall 20.0 ft 27.0 ft 3 Room height 12.0 ft heat/cool 12.0 ft heat/cool 4 Room dimensions 20.0 x 13.0 ft 14.0 x 13.0 ft 5 Room area 260.0 ft2 182.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�j13A-4ocs 0.143 n 4.00 2.19 240 199 798 436 168 153 613 335 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 15 0 126 159 2 glazing,clr low-e 0.300 n 8.40 10.58 41 0 343 432 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 156 156 625 341 11 2 glazing,clr low-e 0.300 a 8.40 29.19 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 10.58 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 260 260 233 416 182 182 163 291 F 22A-tl)h 1.358 38.02 0.00 260 20 760 0 182 27 1027 0 6 c)AED excursion -4 -4 Envelope loss/gain 2134 1279 2553 1122 12 a) Infiltration 531 150 716 202 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 200 300 Subtotal(lines 6 to 13) 2664 1629 3269 1624 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 1 3 14 Subtotal 2664 1629 3271 1626 15 Duct loads 31% 44% 834 724 31% 44% 1024 723 Total room load T3498 2353 4294 2349 Air required(cfm) 1771 107 217 107 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 4 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name KITCHEN FOYER 2 Exposed wall 0 ft 6.0 ft 3 Room height 12.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 263.0 ft 6.0 x 9.0 ft 5 Room area 263.0 ft2 54.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.19 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 48 28 111 60 I!-G� 2 glazing,clr low-e 0.300 s 8.40 10.58 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 20 20 223 211 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 263 263 236 421 54 54 48 86 F 22A-tl)h 1.358 38.02 0.00 263 0 0 0 54 6 228 0 6 c)AED excursion -8 -4 Envelope loss/gain 236 413 610 353 12 a) Infiltration 0 0 106 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2600 1200 Subtotal(lines 6 to 13) 236 3013 716 1583 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 29 52 1 3 14 Subtotal 265 3065 717 1586 15 Duct loads 31% 44% 83 1363 31% 44% 224 705 Total room load 348 4428 942 2291 Air required(cfm) 18 201 48 104 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 5 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name CLST 2 BEDROOM 2 2 Exposed wall 0 ft 20.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 2.0 ft 1.0 x 151.0 ft 5 Room area 18.0 ft2 151.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.19 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 104 89 356 195 I!-G� 2 glazing,clr low-e 0.300 s 8.40 10.58 0 0 0 0 15 15 126 159 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 56 56 224 123 C 16B-30ad 0.032 0.90 1.60 18 18 16 29 151 151 135 242 F 22A-tl)h 1.358 38.02 0.00 18 0 0 0 151 20 760 0 6 c)AED excursion 0 -4 Envelope loss/gain 16 29 1602 714 12 a) Infiltration 0 0 354 100 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 700 Subtotal(lines 6 to 13) 16 29 1956 1513 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -16 -29 15 27 14 Subtotal 0 0 1971 1540 15 Duct loads 31% 44% 0 0 31% 44% 617 685 Total room load 0 0 2588 2225 Air required(cfm) 0 0 131 101 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 6 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name HALL BATH 2 2 Exposed wall 0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 4.0 x 6.0 ft 11.0 x 5.0 ft 5 Room area 24.0 ft2 55.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 40 40 160 88 11 2 glazing,clr low-e 0.300 a 8.40 29.19 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 10.58 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 24 24 22 38 55 55 49 88 F 22A-tl)h 1.358 38.02 0.00 24 0 0 0 55 5 190 0 6 c)AED excursion 0 -1 Envelope loss/gain 22 38 400 174 12 a) Infiltration 0 0 88 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 250 Subtotal(lines 6 to 13) 22 38 488 449 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -22 -38 102 48 14 Subtotal 0 0 590 498 15 Duct loads 31% 44% 01 0 31% 44% 185 221 Total room load 0 0 775 719 Air required(cfm) 0 01 39 33 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 7 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name CLST 3. AHU CLST 2 Exposed wall 2.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 8.0 x 2.0 ft 3.0 x 2.0 ft 5 Room area 16.0 ft2 6.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 16 16 64 35 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.19 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 10.58 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 16 16 14 26 6 6 5 10 F 221%-tr)h 1.358 38.02 0.00 16 2 76 0 6 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 154 60 5 10 12 a) Infiltration 35 10 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 190 70 5 10 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -190 -70 -5 -10 14 Subtotal 0 0 0 0 15 Duct loads 31% 44% 0 0 31% 44% 0 0 FF -T Total room load 0 0 0 0 Air required(cfm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 8 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 BEDROOM 4 2 Exposed wall 32.0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 170.0 ft 11.0 x 12.0 ft 5 Room area 170.0 ft2 132.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 96 96 384 210 96 81 324 177 11 2 glazing,clr low-e 0.300 a 8.40 29.19 0 0 0 0 15 2 126 438 LV�✓ 13A-40cs 0.143 s 4.00 2.19 120 105 420 230 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 10.58 15 15 126 159 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 40 40 160 88 0 0 0 0 C 16B-30ad 0.032 0.90 1.60 170 170 152 272 132 132 118 211 F 22A-tl)h 1.358 38.02 0.00 170 32 1217 0 132 12 456 0 6 c)AED excursion 4 44 Envelope loss/gain 2460 954 1025 871 12 a) Infiltration 566 160 212 60 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 400 550 Subtotal(lines 6 to 13) 3026 1514 1237 1480 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 102 48 7 12 14 Subtotal 3129 1562 1244 1492 15 Duct loads 31% 44% 9791 695 31% 44% 389 663 Total room load 4107 2257 1633 2156 Air required(cfm) 1 1 207 102 1 182198 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 9 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: DEC.10,2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name CLST 4 2 Exposed wall 0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 2.0 x 9.0 ft 5 Room area 18.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6V�j13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 10.58 0 0 0 0 V�✓ 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 11 l C 2 glazing,clr low-e 0.300 e 8.40 29.19 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 2 glazing,clr low-e 0.300 s 8.40 10.58 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 W 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 18 18 16 29 F 22A-tr)h 1.358 38.02 0.00 18 0 0 0 6 c)AED excursion 0 Envelope loss/gain 16 29 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 16 29 Less external load 0 0 Less transfer 0 0 Redistribution -16 -29 14 Subtotal 0 0 15 Duct loads 31% 44% 0 0 Total room load 0 0 Air required(cfm) 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k —r"- wrigl 2020-Dec-1012:58:50 Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 10 ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S L-7 wrignI Duct System Summary Job: GARAGE LEFT Date: DEC.10,2020 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: BILTMORE MODEL, FY CONSTRUCTION 105 SE CELESTIA COURT, PORT ST LUCIE, FL Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/ return available pressure 0.500/ 0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1200 cfm 1200 cfm Total effective length (TEL) 182 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH 2-A h 775 39 33 1.000 5.0 Ox 0 VIFx 4.5 95.0 BEDROOM 2 h 2588 131 101 1.000 7.0 Ox0 VIFx 12.1 95.0 BEDROOM 3-A h 4107 207 102 1.000 7.0 Ox0 VIFx 9.2 95.0 BEDROOM 4 c 2156 82 98 1.000 7.0 Ox0 VIFx 18.1 115.0 st1 DINING h 4294 217 107 1.000 7.0 Ox0 VIFx 19.5 115.0 st1 FOYER c 2291 48 104 1.000 7.0 Ox0 VIFx 28.3 115.0 st2 GREAT ROOM h 3498 177 107 1.000 7.0 Ox 0 VIFx 39.5 115.0 st2 KITCHEN c 2214 9 101 1.000 7.0 Ox0 VIFx 28.6 115.0 st2 KITCHEN-A c 2214 9 101 1.000 7.0 Ox0 VIFx 18.3 115.0 st1 M BATH h 2036 103 48 1.000 6.0 Ox0 VIFx 47.2 135.0 st3 M WIC h 1003 51 35 1.000 5.0 Ox 0 VIFx 38.6 135.0 st3 MASTER BEDROOM c 2332 62 106 1.000 7.0 Ox0 VIFx 39.5 135.0 st3 MASTER BEDROOM-A c 2332 62 106 1.000 7.0 Ox0 VIFx 38.6 135.0 st3 UTILITYRM c 1147 4 52 1.000 6.0 Ox0 VIFx 38.4 135.0 st3 • • Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 281 347 1.000 637 10.0 0 x 0 VinlFlx st2 st2 Peak AVF 514 659 1.000 839 12.0 0 x 0 VinlFlx st1 Peak AVF 308 305 1.000 565 10.0 0 x 0 VinlFlx )l ftu-P�F W ri 2020-Dec-10 12:58:56 . -........., .,a... Right-SuiteO Universal 201919.0.08 RSU08101 Page 1 �L •-' ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 1200 1200 0 0 0 0 Ox 0 VIFx )I ftu-P�11- W ri 2020-Dec-10 12:58:56 . -........., M„ .,a... Right-SuiteO Universal 2019 19.0.08 RSU08101 Page 2 �L •-' ...Wrightsoft HVAC\BILTMORE MODEL-CELESTIA CTrup Calc=MJ8 Front Door faces: S This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.