Loading...
HomeMy WebLinkAboutWINDLOAD FORM Planning&Development Services Department • Building&Code Regulations Division M ' 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: FY 566 Project Address: 105 SE CELESTIA, PT. SAINT LUCIE, FL 34983 Permit#: Occupancy Type:R-3 Construction Type:5-B INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential, (3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Sixth Edition with 2020 Supplements using ASCE 7-10 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph ASD LRFD End Zone Width:4•4 ft 5. Mean Roof Height 15 ft Roof Pitch:4 :12 Parapet:N/A ft 6. Components&Cladding Design Pressures Used: (PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1:+28.3/-63.7 Zone 2:+28.3/-83.0 Zone 3:+28.3/-89.4 Zone 4:+37.8/-41.0 Zone 5:+37.8/-50.7 Garage: +31.9/-38.8 7. Design Loads: Floor:2500 PSF Roof/Dead:25 PSF Roof/Live:30 Balcony: N/A PSF Dock:N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure?X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided?X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure:2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Lillian Gonzalez �P"`ESZq<F- Digitally signed J Y by ^° Lillian Gonzalez Print Name Cert#&Co. Cert Auth. A=Date:2021.01.08 79442 9'. STATE OF 12:50:27-05'00' ,,`�S' G•. 'SrONAL EN.•• Signature, Date, and Seal Goarch Engineering, Inc- 1824 Richard Ln Palm Springs, FL 33406 Company Name&Address Revised 12/07/2018