HomeMy WebLinkAboutBuilding Plans1430 CULMER DRIVE NE, PALM BAY, F=L 32907
• STATE OF FLORIDA DESIGN CRITERIA:
CERTIFIED BUILDING CONTRACTOR: •FLORIDA BUILDING CODE, RESIDENTIAL,
6TH EDITION (2017)
*ALL LOCAL AND STATE CODES
DR HORTON HOMES
1430
CULVER DRIVE NE
PALM
BAY, FL 32907
TEL:
(321) 733-7092
FAX:
(321) 733-7972
• STATE OF FLORIDA
PROFESSIONAL ARCHITECT:
MICHAEL C. ANDERSON
AR No. 17305
A.B. DESIGN GROUP, LLC
551 S. APOLLO BLVD., SUITE 202
MELBOURNE, FLORIDA 32901
Tel: (321) 802-3591
DRAWING / CONTRACT DOCUMENT
REVIEW BY BUILDER
THE BUILDER ASSUMES ALL LIABILITY FOR
INTERPRETATION OF THE CONTRACT DOCUMENTS.
IF ANY ASPECT OF THE CONSTRUCTION (AS
DESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND
IN NEED OF FURTHER DETAILING OR EXPLANATION IN
ORDER TO BUILD THIS PROJECT BASED ON THIS
DRAWING SET, THE CORRECT PROCEDURE IS FOR THE
BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR
INFORMATION) TO THE ARCHITECT OR ENGINEER FOR
CLARIFICATION.
AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN
RFI's IN WRITTEN/DRAWN FORMS IN A TIMELY
MANNER. AB DESIGN GROUP TAKES NO
RESPONSIBILITY FOR INTERPRETATIONS OF
CONSTRUCTION BY THE 'BUILDER WHEN NO RFI's HAVE
BEEN GENERATED FOR UNCLEAR ASPECTS OF THE
CONSTRUCTION BASED ON THE DRAWING SET.
•OCCUPANCY
•CONSTRUCTION TYPE
• MIN. INTERIOR FINISH
•BASIC WIND SPEED
•EXPOSURE
el —STORY RESIDENCE
•2—STORY RESIDENCE
— RESIDENTIAL, GROUP R3
— VB
— CLASS B
— Vult=160 MPH
Vasd=124 MPH
—C
— MAX. HEIGHT AS PER LOCAL
AND STATE CODES
SQ.FT.
CALC.'S
1ST FLR. LIVING
1104
SQ. FT.
2ND FLR. LIVING
1501
SQ. FT.
TOTAL LIVING
2605
SQ. FT.
GARAGE
43-1
SQ. FT.
PORCH
III
SQ. FT.
COVERED LANAI
80
SQ. FT.
TOTAL
3233
SQ. FT.
A/C VOLUME 224032 CU. FT.
Tel= (321) 733-7092
Fax: (321) 733-7972
ABBREVIATIONS I REVISIONS
ARV.
ADS
ALT.
AMP_
BD.
CT,
CAR.
CLG.
.R.
CON('.
CPT
ABOVE
DJU wDLTLC)NISC
1LIH2 :ABLE
AMPLR!ATF,
BOARD AGE
CENTEF
CABLNL. LINT;
CTIL.INCT
C I CAR
(ONCRI,
C ARPLI-Te
LAV
LUM.
M.0
MPR.
MIN.
M.T.
'MTD.
MTL.
NTs_
O'C.
PL
P_R.
LAVATORY
AIEll1C INE CABINET
MEDICI E
MANTiT'AC'TURER
MINIMUM
NIFTALTHRESHOLD
MOUNTED
METAL.
NOT TO SCALE
ONCENILR
PI OPERI Y I_INI_
PUSH BUIION
DATE
DESCRIPTION
2-STORY CMU CONVERSION
APPLIED COMMENTS FROM M. SEA'
51D SET ISSUED
, , PER MARK 50WES
ADDED ELEv. J E K WITN SIDIPdd
51D SET RE -ISSUED
FOOTING REVISIONS PER M. 50U1E.9
0628A1
1245/11
01/16AB
02/13/18
02/20/18
04AJIIB
08AT/18
C.T.
D.
DBL..
CERAMIC HLE
DRYER
T)OUBLI-
PH
VI ,T.
PIYWD.
PHONT
PLAIT:
PLYWOOD
ADDED VALLEY FRAMING DETAIL; UPDATED BOLLARD DETAIL
DETAIL- 'ADDING BAR TO BOND SEAM' ADDED TO &1.2A
01/26/19
D.C.
DI'AT CLA7FD
PR.
PAIR
DIA,
DTAMF1'FR
P.T.
PRESSURE TREATED
02/26A9
PLAN MAINTENANCE
DIAL
DISP OS >\
DIYPAL
R
RAll.
RISER;
RADIUSDISP.
03/29/19
REVISED LINTEL SIZE AT FRONT ENTRY DOOR
04/25A9
ADDED ADDITIONAL RECEPTACLE IN GARAGE PER WILL BATSON
UP.
OR,
DEEP
DOOR
REF.
REF.
RETURN Ala GRILE
REFRIGFR4'1'OR
04/25A9
REVISED HVAC VOLUMES ON SCFT CALC SCHEDULE
DS. DOWNSPOUT RNT. ROOM
DTI_
DETAIL
R O.
ROUGH OPENING
04/26/19
UPDATED LEDGER BOLT SIZE t SPACING
D.W DISHWASHT-R s C SOLID C ORE TXTDR,
P.A.
EACH
S.D_
SMOKE DETECTOR
FIEV_
ELEVATION
S, [I
SINGLE IIUNG
06AW9
REVISED I -JOIST LAYOUT
Fp.
BXH.
FQUAL
EXHAUST
EXHAUST
SHT.
SHTHG.
SHEET
SHEA�EHING
06/21/19
ADDED LED LIGHTS TO KITCHEN t BATHROOMS PER MARK BODES
09/13A9
LEDGER BOLT SPACING vISED
EXT.
P.GJr'x.
I__X II:RIOR
FIXEDGLASS
sli% R.
SDO
SHOWER
SIMILAR
F G. FUEL GAS SL. SLIDING
PTV_
FINISH
SL. CT..
SLIDING GLASS
IIR_
FLOOR
STD.
STANDARD
FLUOR.
F'I UORPSC'FNT
SWS
SHEAR WAIT.
FR. DR.
FRRNCH DOOR
SECTION
FTC_
POOTINCi
TGAIR
TEMPERED GLASS
GA.
GAUGE
IHK.
THICK
G,1R_DISP_ GARBAGE DISPOSAL IO.('. TOPOE CURB
GL'1'
GROUND -FAULT CIRCUIT
T.O.P.
TOP OF PT_ATP
IN IERRUPTER T.O.S. TOP OF SLAB
CL_
GLASS
TYP_
TYPICAL.
-
GYP. BD. GYPSUM BOARD I.N.O. UNLESS NOTED
H.B.
HORRBIR
OTHERWISE.
H.C.
HOLLOWCORT
VP_
VAPOR PROOF
HDR.
HRADFk
NV'
WASHER
HGT.OR HT
IIFIGITT
W/
WITH
INSUI_ INSULATION R'D. WOOD
INT.
INTP_RIOR
WDW_
WINDOW
W/H WATER HEATER
W.L.
WROUGHT IRON
Fib 0 4 Pon
M1%
INDEX OF DRAWINGS
ARCHITECTURAL SHEET
PG
CS —COVER
SHEET
PG
GN—GENERAL
NOTES
PG
Al —FIRST
FLOOR PLAN
PG
AlA—FLOOR
PLAN SECTIONS/DETAILS
PG
A2—SECOND
FLOOR PLAN
PG
A3H—FRONT
& REAR ELEVATIONS "H"
PG
A411—LEFT
& RIGHT ELEVATIONS "H"
PG
E1—FIRST
FLOOR ELECTRICAL PLAN
PG
E2—SECOND
FLOOR ELECTRICAL PLAN
PG
Pl—PLUMBING
PLAN
PG
Ml—FIRST
FLOOR HVAC PLAN
PG
M2—SECOND
FLOOR HVAC PLAN
PG
Di —DETAILS
PG
D2—DETAILS
PG
D3—DETAILS
PG
WAl—WALL
ASSEMBLY DETAILS
PG
WA2—WALL
ASSEMBLY DETAILS
PG
WA3—WALL
ASSEMBLY DETAILS
PG
WA6—WALL
ASSEMBLY DETAILS
STRUCTURAL SHEET
DESCRIPTION
2rwz—z-,imel
REVIEWED FOR
MODE COMPLIANCE
ST, LUCIE COUN11ye
BOCC L
PG S1—FOUNDATION PLAN
PG S1.lA—DETAILS
PG S1.2—FIRST FLOOR DOWEL PLAN
PG S1.2A—DETAILS
PG S2—FIRST LIFT BEAM PLAN AND NOTES
PG S2.1A—DETAILS
PG S3—FIRST FLOOR FRAMING PLAN
PG S3.1A—DETAILS
PG S3.113—DETAILS
PG S3.1C—DETAILS
PG S4—SECOND FLOOR DECK PLAN
PG S4.2—SECOND FLOOR DOWEL PLAN
PG S5—SECOND LIFT BEAM PLAN AND NOTE
PG S6—ROOF FRAMING PLAN
PG SN1—DETAILS
PG PA1—PRODUCT APPROVALS
DESCRIPTION
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
F
rA
114
W
O
F
R.
V
W
C
F
A
F:
SUBDIV. & LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
COVER
SHEET
160 MPH EXP. C
ARCHITECT
STATE OF FLORIDA
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305
PRINT DATE: 10 14 19
SCALE: 1/4"= l' — O"
SHEET
c IS
GENERAL NOTES
SITE WORK
1.
ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR)
1.
REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT).
TIMBER
6th EDITION, (2017) .AND IN CONJUNCTION WITH ASCE 7-10. ALL REFERENCED CHAPTERS, CODE SECTIONS
AND TABLES STAT
D
1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED
IN THESE DOCUMENTS ARE UNDER FBCR 6TH EDITION (2017) UNO.
2.
REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES,
HEREIN:
SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL
A AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL)
2.
WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR
DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL
B. NATIONAL FOREST PRODUCTS ASSOCIATION:
BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY
FINISH GRADES, PLANTING AND IRRIGATION.
I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION
THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL B
C. SOUTHERN PINE INSPECTION BUREAU:
DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2
3.
ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE
I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER
ARCHITECT.
D. TRUSS PLATE INSTITUTE:
3.
DO NOT SCALE DRAWINGS, THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK
I NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI-2014)
PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
4
NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN'/2 THE HORIZONTAL
E. A1PA . -THE ENGINEERED WOOD ASSOCIATION:
i. ENGINEERED WOOD CONSTRUCTION GUIDE
DISTANCE FROM THE NEAREST EDGE OF THE FOOTING.
F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS
4.
THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTIO
J
OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK
5
ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL. PLACE IN 8"
2. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED.
THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE
o
LAYERS AND COMPACT TO 95 /o MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH D1557. THE
CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR
BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS.
3. MINIMUM NAILING PER CHAPTER 6- WA CONSTRUCTION
WALL COS UCTION AND TYPICAL NAILING SCHEDULE ON PLANS:
FABRICATION OF THE WORK.
5.
THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES TECHNIQUES,
6
COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED.
4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION.
OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODE
S.
7,'
DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE)
5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1.
6.
THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR
8.
EXCAVATIONS TO BE A MINIMUM OF 3 0 BEYOND NEW FOOTING LINE.
6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL 24" AND THE MINIMUM AREA SHALL BE 8 FT SQ.
SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING
.
CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED.
9.
THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE
PLUMBING
7.
DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS.,
REQUIREMENTS.
1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40)AS APPROVED BY THE BUILDING OFFICIAL.
2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX "A" (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS.
8.
THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER
10.
THIS BUILDING IS NOT DESIGNED TO A FLOOD ZONE, UNO. CONTRACTOR IS TO VERIFY THE
3. CONDENSATION LINES SHALL BE MINIMUM %" PVC (SCHEDULE 40), INSULATED WITH" AMAFLEX.
'/2
ELEVATION OF THE FINISHED FLOO
AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL
�
4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH.
9.
NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED.
CODES HAVING JURISDICTION, INCL
FILLUSTATE,
CITY, AND COUNTY BUILDING AND ZONING CODES
5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE.
6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS OR RIDGES,
GARAGES AND CARPORTS
11.
SWIMMING POOL; DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP
7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2,.
1.
GARAGE DOOR
DRAWING
8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903
A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET
9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE,
B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER
12,
TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES,
10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2.
C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER
BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMENT PROTECTION
LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE
EXTERIOR WALL COVERINGS
2.
AS PER SECTION R302.5.BE OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING
APPLICATION 0 E I EDT THE
F THE TERMITE. PROTECTIVE TREATMENT; A CERTIFICATE OF COMPLIANCE SHALL B ISSUED 0
1. ALL EXTERIOR WALL COVERINGS AND SOFFIT HALL BE
S S CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR
PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH
BUILDING DEPARTMENTSTATEMENT:
BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWINGS
THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH
C TABLE R30L2(2) AS MODIFIED BY TABLE
IN THICKNESS SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS
SOLID WOOD DOORS NOT LESS THAN 1 THICKNESS, SOLID
INCHES"THE
AN
BUILDING HAS RECEIVED A COMPLLTE TREATMENT FOR!; THE PREVENTION OF SUBTERRANEAN TERMITES
R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE
1-3/8 INCHES THICK, OR 20 MINUTE FIRE RATED DOORS.
RA
TREATMENT 1S IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF
3.
AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRA THE WALLS�OR CEILINGS SEPARATING THE
AGRICULTURE AND CONSUMER SERVICES."
EXTERIOR FINISHES
DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A'MINIMUM NO 26 GAGE (0.48 MM) SHEET STEEL 1" MIN. RIGID
1. WHEN PLASTERING WITH CEMENT, PLASTER'SHALL NOT BE LESS THAN THREE COATS, 4" THICK, OVER FRAMED WALLS
ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR 0101a' APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE
APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERB OF VAPOR BARRIER, NOT LESS
GARAGE. '
THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE.
2 STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIMED IN ACCORDANCE WITH
I�
SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NQT
ASTM-C926 & ASTM-C1063-12a.
4.
AS PER SECTION R302.6 & TABLE R302.6: THE GARAGE
LESS THAN 1/2 -INCH GYPSUM BOARD APPLIED Td THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE
3. LATH & ACCESORIES PER ASTM-C-1063-11A & R703.7.1. ALL STUCCO APPLICATION DETAIL§ INCLUDING BUT NOT LIMITED TO:
SEPARATED FROM ALL HABITABLE ROOMS ABOVA BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT.
ALL STUCCO CONTROL JOINTS KICK -OUT DET,
LIES
WHERE THE SEPARATION IS A FLOOR -CEILING APMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE
"L" FLASHING HORIZONTAL
- NTH AND PAPER DETAILS
PROTECTED BY NOT LESS THAN'/2-INCH GYPSUM BOARD OR EQUIVALENT.
PIPE PENETRATION DETAILS VENT PENETRATION DETAILS
WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS
".. u
CASING BEAD DETAILS DRIP EDGE DETAILS
CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS
WINDOW CASING DETAILS _ STUCCO TO SIDING TRANSITION DETAILS
WINDOW FLASHING DETAILS
4. SHALL BE INSTALLED PER ASTM-C1063 -11A AND R703.7.w.
FIRE RESISTANT CONSTRUCTION
UNDER STAIR PROTECTION:
1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED
ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. R302.7.
CONSTRUCTION OBSERVATION
CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF AB DESIGN GROUPS
SERVICES FOR THIS PROJECT.
IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW
OF THE BUILDER'S / CONTRACTOR'S PERFORMANCE OR ANY OTHER CONSTRUCTION' PHASE SERVICES, AND THAT SUCH SERVICES WILL
BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND
FOR CONSTRUCTION OBSERVATION.
EXTERIOR CEILINGS
1. EXTERIOR CEILING TO BE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING
MEMBERS. THE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1
1/4" TYPE°"W" DRYWALL SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS) .
ole�
4ZO
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA32901
I PH: 321-802-3591
www.abdesigngroup.com
` AA #: 0003325 J
,49M"-
7,
w
lw
I�
z
6
U
r� G
I,
I
�F
CREEKSIDE
LOT #72
F
�1
PROJECT#
04321.200 072R1
OIDEX.
4EHB
"',"605- HAYDEN
"
RIGHT
�g
?' AGE:
GENERAL
NOTES
NZ
' [PH EXP. C t
ARCHfTECT
STATE OF FLORIDA
DCT 1 7 2019
C.�QNDERSONI
:AR NC a `1173 i5
I - Tit I 1T 10 14 19
�A / /
SCALE: 1/4"=1'-0"
SHEET
,
IN G
t
J`p`
CONTROL DATE: 07120119 (CM)
[4Y'
J
AROUND
WIND DESIGN
SEISMIC
SUBJECT TO DAMAGE FROM
IWINTERI
ICE BA
IER
FLOOD
AIR
MEAN
SNOW
DESIGN
DESIGN
UNDERTL
ENT
HAZARDS a
FREEZING
ANUAL
SPEED
TOPOGRAPHIC
WEATHERING"
FROST LINE
TERMITE°
j
LOAD
(MPI-I)'
EFFECTSk
CATAGORY°
DEPtHb
TEMP'
iv"'EQUI
Dn
INDEX'
TEMPI
NA
I60 C
NA
jNEGLIGA5LE
I NA
I VERY HEAVY
42
NA'
SEE -SURVEY1
NA
I NA
FLAME, SPREAD AND SMOKE INDEX FOR WALL AND CEILING FINISHES SHALL BE IN
ACCORDANCE WITH SECTION FBC R302.9.1 THROUGH FBC R302.9.4
FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN
m"
0'-0"
ACCORDANCE WITH SECTION FBC R302.10.I THROUGH FBC R302.105
4"
7'-41 -4'L
391_811
2l' -10"
COVERED
LANAI
I I
I
` I H B.
6068 S.G.D. (2) 3052-5H
0
2 -S
3052-SH
EGRESS
12-1'-4"
0
DINING I BEDROOM #2
ROOM I e LIVING n e s cLG.
FISE-EP1Cs TRUSS n 8'-8' CLG. I ROOM
DOUBLE TOP PLATE 2x CONTINOUS STRESS i 8'-8' Cl-G.
BLOCKING MID WALL
SP4.32'O.-MAx tY _�'_ 3` 8 5'-8" 3'-S" 6'-10, 3'-8 9'-0"
2x STUD8 • 16' OZ. MAX,
UDl1 Ql _
;' T a G SUBPLoOR GLUED
AND SCREWED AS PER I �{Q
FASTNER SCHEDULE (Z) 2ID6S
A
IST FLOOR STUDS TO
2ND FLOOR STUDS I I I '-
61MPBON MSTA-36 •
32' Or— MAX Ell
p I z�QIPOST II �PIE_rT FLOOR TRAS L'' - 1TU Il/ ILD
O VIC II CIV
a BATH #2
II a'-s' cLG
a --- _
--------------
KITCHEN � ��.; � y I I C
8' CLG. Q 74-o
DOI 01 F TOP PLATE 2x STUDS • I6. OG MAX, rr • _. 'n
vAx 2x CONTINOUS STRESS SECURE BT. PLATE TO STUD W/15LOCKNG MID WALL SIMPBCIJ W4 aw or-MAXSECUR'_ BT. PLATE TO SLAB -
W/Rj'9'ANICHORBOLTW/2' �0 2'-8" �� S'0" I ° ° 3-8 5'-4" 3'-4" 5-8" 3'
WASHER T' EMBED. MIN.. 32' `�
HEIGHT OF GARAGE OG. MAX, EPDXY NOT -_-- 2868 SC W.H.
VARIER WITH SLOPE REQUIRED FOR EXPANSION .�. �, i -- pP f i STAIR DATA A 20 MIN. //P U
L
W eoPOe i REFi — Irv' RISER ® l54'
�"''�� � 3-SH i � i -- ARCH 15 TREADS a 1ID' Ai
BOLLARD OND.
PC===V ASREQ.
- •' ' 4• CCW— REINFORCED W) •'X&' WL4XIJA - B PER BLDG..
' W6F OR NOERMESH ON 6-MIL VAPOR -» CODE
Z RETARDER ON I'm I-cON1PACTED CLE
w AN II
.. FILL- TERMITE TREATMENT TO BE
U I'I ® BOR.A-CARS. E APPLIED AT FRAMIW
(2) 9 R12AR ON 0"IRe
GARAGE
n III
2 STORY INT. WALL AT GARAGE FLEX Gllly FOYER
A SCALE:
m
3068
III W/12'
III TRANS 2'-10" 6'_0" '-10" I°
- nt�
I I :, .I I:I r•1I�1
(2) 3052-SH I 10„
PORCH b
0 g1.61 CLG I � 16'-0' X 11-0' O.W.
1 If l r--------------
`�---------- ---- 7
— v
1771— 1:11.1
'74" ®'-0"
ra a'.. ... 9 -�' 20' 4
18 -®" 21'-8"
O ALLS t� s
FIRST FLOOR PLAN
SCALE: 1/4' = 1'-0'
NOTE:2-STORY GYPSUM BOARD
I
...: OPENINGS BETWEEN THE GARAGE E RESIDENCE SHALL BE
a EQUIPPED WITH SOLID WOOD DOOR NOT LESS THAN 134'
(35mm) IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL
pp I DOORS NOT LESS THAN 14b'(35mm) THICK, OR 20-MINUTE
t� n FIRE -RATED DOORS
f r € *'
THE GARAGE SHALL BE SEPARATED FROM THE RESIpEN�E ITS
ATTIC AREA BY NOT LESS THAN 1/2'(12.1mm) GYPSUM BOAMa APPLIED
TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE FWOMS
W 0z AV HINR000S SHALL BE SEPARATED FROM ALL HABITABLE ROOMS B'f NOT LESS
THAN %'(15.9mm) TYPE X GYPSUM BOARD OR EQUIVALENT
UNDER STAIR PROTECTION:
N= r ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS,
N,Ac i, fax �3 a - _, * UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED
FIGURE ,2(7) SIDE WITH 1/�2 INCH GYPSUM BOARDS. FBCR 2011 (6TN ED.) 302.1
COMPONENT "NT AND CLADDING PRESSURE, ZONES
IRi
15'_4"
SQ.FT.
CALL. S
IST FLR, LIVING
2ND FLR LIVING
1104
1501
SQ. FT.
SQ. FT.
TOTAL LIVING
GARAGE
PORCH
COVERED LANAI
2605
431
III
80
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
TOTAL
3233,
SQ. FT.
A/C VOLUME
22403.2
GU. FT.
•. . _ .. pot . .. m:
. 1'.4 .' . •• t Ljj
OPBfP
AND TYPE
DO
FOOTAGE
ZONE
100 MPH WIND M
REMARKS
MIN. WINDOW
10
5
34/-45
CRITERIA
EXTERIOR SWING
21
5
32/-42
DR MIN. CRITERIA
S.G.D. MIN.
14
5
30/-3l
�1
CRITERIA
56
s
8010 O.H.D.
5
325/-38.0
}
160l0 O.H.D.
112
5
30.9/-34.4
SOFFIT
N/A
5
I 31b/-38.8
a ROOF TILE N/A -6829/ IF
3
. -58.29 APPLICABLE
BASIC WIND SPEED MPH = 160 (Vult) INTERNAL
PRESSURE COEFFICENT = t 0.18 BLDG. CAT.=II,
EXP.=C, MEAN ROOF HT. = 15'-9"
PRESSURES HAVE BEEN MODIFIED PER FBCR 6TH ED.
(2017) R301.2.1 TO MEET TESTED ALLOWABLE OR
NOMINAL WIND LOAD VALUES FROM THE PRODUCT
MANUFACTURER. COMROL DATE 03/20/16
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA3290
PH: 321-802-3591
www.abdesigngroup.com
AA # 00003325
I-17. 8e LOT:
CREEKSIDE
LOT #72
4
jROJECT#
04321.200 072RI
.`
MODEL:
{ 4EHB
k
Iv 99 9"
2005—HAYDEN'
,41
AGE SWING:
RIGHT
:
�-
=I�
T`AGI IE
r
'
" FIRST
FLOOR PLArd
� n
� yam_%z
ARCHFECT•
STATE OF FLORUA
,ZCT 17 2019
MI EL C. AiNDERSON
AR NO 17305
DATE- 10/14/19
SCALE: 1 /4"= V — 0"
20 i'. aio
L
i
A BAR -DETAIL
ARCH DTL.
B SCALE: I/2'=1'-0'
42' H. HALF WALL
W/ CAP
3/4' TtG SUB FLOOR
GLUED i SCREWED
PER FASTENER
SCHEDULE
10'-0 3/4' 2ND FIN. FLR.
V-8' BRCS. HCsT.
(2) LAYERS OF 3/4' PLYWOOD
OR (2) LAYERS OF 3/4' SUB
FLOOR MATERIAL RIPS FOR
SOLID NAILING /
SECURE TREADS TO STRINGER
WK3)'8 3' SCREWS • EA
STRINGER, UNTHREADED SHANK
TO EXTEND BEYOND THICKNESS
OF SUB -FLOOR SHEATHING
� PRE-ENG'D
FLOORING SYSTEM \ \
(SEE FLOOR \
FRAMING SHEET) \
/4' KICK
NOTE \ PLATE I' MAX.
STAIRS RISERS TO CONFORM TO FBCR 6TH \ \oSIVCs
EDITION (2011) \ MIN. O
MIN. TREAD=10' MAX. RISER-1 3/4' 3/16. STAIR DATA:
MAX. VARIATION IN RISERS/TREADS 16R ®� r�q • \ r
ADJACENT TO EACH OTHER 3/8' MAX, 15 TREADS A S T 0 R • \ a
VARIATION IN ANY RISER/TREAD HANDRAIL 10'+ 1' NOSING
CIRCULAR CROSS SECTION DIA. TO BE 1 1/4' w U
+-1/4' OR PROVIDE EQUIVALENT
GRASPABILITY WINDERS- MIN. 6' WIDE • 3-2x12 SYP STRINGER \ = Q
NARROW END MIN. 11' WIDTH • 12' FROM REINFORCED W/2X4 SPF \ = z
NARROW END 34' MIN. HANDRAIL HGT. W/CONT. BEAD OF f w
NOTE:
*ENCLOSED ACCESSIBLE SPACE UNDER
STAIRS SHALL HAVE WALLS, UNDER STAIR
SURFACE AND ANY SOFFITS PROTECTED ON
THE ENCLOSED SIDE WITH 1/2' GYPSUM
BOARDS. FBCR 3021.
SUB -FLOOR ADHESIVE
PL-400 OR SIMILARE • \ U
EA HORIZONTAL RUN
1 SECURE STRINGER
O.C.
\ \
STAIR SECTION
C
'^\ M11 Fi`"w W IIVG
MASONRY NAILS a 2X4 P.T.
SLEEPER INTO SLAB WITHIN 8'
OF EACH END, 32' O.G. MAX.
AHU
42' H. 1/2
WALL W/
CAP
HANDRAIL a 36'
W/ 2X4 RE-INFOR
THE CLEAR SPACE BETWEEN
THE HANDRAIL AND THE WALL
SHALL BE NO LESS THAN 1 1/211
AS PER FBCR R311.18.2
NOTE:
HANDRAIL ENDS SHALL BE
RETURNED TO THE WALL OR
TERMINATE INTO A NEWEL
POST.
NOTE:
I. HANDRAILS SHALL HAVE EITHER A CIRCULAR CROSS SECTION WITH A
DIAMETER OF la"± 2" OR A NONCIRCULAR CROSS SECTION WITH A
PERIMETER DIMENSION OF AT LEAST 4" BUT NOT MORE THAN (o 1/4" AND
A LARGEST CROSS SECTION DIMENSION NOT EXCEEDING 2 1/4'. EDGES
SHALL HAVE A MINIMUM RADIUS OF 1/5".
2. THIS RAILING SYSTEM IS DESIGNED TO RESIST ,A LOAD OF 50 PLF
FOR A CONCENTRATED LOAD OF 200 POUNDS APPLIED IN ANY
DIRECTION AT THE TOP OF SUCH BARRIERS AT ANY LOCATION ON THE
SAFEGUARD, WHICHEVER CONDITION PRODUCES THE MAXIMUM
STRESSES- PER SECTION 160-1B.1 / F.B.G. 201-1
HANDRAIL SECTION
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
y
�I
U
w
>� w
0.
W
q
"4 SETA 8e LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SUITING:
RIGHT
PAGE:
FLOOR PLAN
SECTIONS
DETAILS
60 MPH EXP. C
ARCHrrECT:
STATE OF FLORIDA
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305 0
rscaar a DATE-
10 14 19
SCALE: 1/4"=1'-0"
34HEET
AI A
2'-4"
1-4111
3052-SH,
G' -MC CC
BEDROOM 4
�1
1
V
'/
---
W.c. o
4'-41, 3' 0" 2 -411
BEDROOM #3
8'-81 CLG.
r
EGRESS
(2) 3052
I
UPSTAIRS
LIVVING
SI rl r.LG.
I
W.I.C.
8'-81 CLG.1 ATTIC: I I °�
WGCESS i I — rn
omcm
®�:=1
1� 2
F6YAW
;
i�
W.LC.
8'-81 CLG.
I
t
LINE OF IST I -_
FLOOR BELOW J TEMF
----- ------ — — — -------
10 0" S'-0" 5'-4"
13'-4" 2'-4" 2'-4' 8'-0"
18'-01
391- S lI
ffl�%3Y
2'-t311
3052 -SH
BEDROOM #5
8'-81 CLG.
c
�4'-2'
G
"..- 6'_61
OFT. ii ffT
0. u1 W. i
OWNER'S SUITE
8'-8' CLG.
14'-0"
3052-SH
EGRESS
7-4°
SECOND FLOOR PLAN
SCALE: 1/4 = 1'-0'
3052 -SH
EGRESS
71_01
13'
N
r
FrrRrrn
w
y
U
W
13
F
0.
w
4
F
A
ti
SUBDIV. & LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
SECOND
FLOOR PLAN
60 MPH EXP. i
ARCHrmcT-
STATE OF FLORIDA
V),--L-
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305
PRINT 10 14 /19
DATE• /
SCALE: 1/4"=1'-0"
SHEET
A 2
SHINGLE
FYPON "
DECORATIVE
VE
SHUTTER OR
EQUIVALENT
2ND-1 LR.
BRCx. 1-4GT.
FYPON
BKTI IXI1
OR
EQUIVALENT
6' RAISED I I 6' RAISED
BAND (TYR) I I 12 7 BAND
0' 0 3/4,'r�10'-0 3/4"
2ND FIN. FLR. I ''2ND FIN. FLR-
8 _ �__ _ �8'-8" CLG. HGT.
3 ENTJ✓� OPT. COACH
45
I I
A I ��
4' RAISED TYP. I I 0
BAND (TYP.) I
8' RAISED
BAND (TYR) I
0 -0" FIN. FLR,r, I —
I5'-8" 2ND FLIP, _
SRG. HGT.
I
i
I
i
I
' I
I
10'-0 3/4 2ND
FIN. FLR./BRCs. HGT_
8'-8" CLG. HGT.r I
4B
i A
I
TYP.
' I
j
0'-0" FIN. FLR.
II�
I1�
FRONT ELEVATION
FLASHING AS PER FBCR R103.4
OFF RIDGE VENT
Ia
r H
12
_ — _ — _ — _ — — — _ — _ — — —
II II�
CL
k
I I
I I
I I
4B I I
A I
I I
TYP_
-----------------I
R EAR ELEVATION
SCALE: 1/4 = I'-0' TEXTURED FINISH
LIGHT
m
0
-- _ 60'-0" FIN. FLR.
_ 18 -8 2ND FLR.
BRG. HGT.
r
3/1' 2ND FLR.
FIN. FLR./BRG. HGT.
_ 8'-8" CLG. HGT.
oO'-O" FIN. FLR.
MODEL 2605- HAYDEN -4EHB (2-Story) j
AREA OF ATTIC
= 1541 SQ_ FT.
NETFREE VENTILATION AREA
REQUIRED
1/ 300
REQUIRED VENTILATION AREA
= 1541 /300
= 5.14 SQ. FT.
5.14
= 739.68 SQ. IN.
MIN. REQUIRED VENTILATION
= .4X 739.68
IN UPPER PORTION OF ATTIC
= 295.872 SQ. IN.
(BALANCETO BE PROVIDED IN
SOFFIT VENTS)
OFF RIDGE VENTILATION AREA
= 138 SQ. IN. PER VENT (net free area)
TOTAL# OF VENTS REQUI RED
= 2.14
TOTAL tt OF VENTS PROVIDED
= 3
SOFFIT VENTILATION AREA
7 SQ, IN.PERLINEAR FT(net free
area)
LINEAR FEET OF SOFFIT REQUIRI
42.27
551 S. APOLLO BLVD.,
SUITE 202
IELBOURNE, FLORIDA3290J
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
El
r�
W
h x
k
�
I
h
G k+
r4
61
"
N�
+I
E
s
I
I[
tE
ty
h
Poi
I'y
M1
4EEt''
e
k
6'
I
xf
SUEO11� 8e LOT:
a
g� CREEKSIDE
LOT #72
,PROJECT
ROJECT
04321.200/072R1
MODEL: `
4EHB
"2605—HAYDEN"
,GARAGE S WMG:
RIGHT
.GE:
FRONT & 4
REAR
ELEVATION "H"
r
u MPH EXP. C
.S µ ARCHPT�CT �r t
STATE OF FLORIDA
MIN. ,'HA .:L
AR WY) 1911305
DATE: 10/14/19 1.
SCALE: 1 /4"=1' — O"
SHEET
o
IS'-S" 2ND FLR.h
10'-0 3/4' 2ND FLIR
FIN. FLRJSRCz. HCsT_
8'-8' GLa. H4GT_�
i
0'-0" FIN. FLR. -
I,&'-8" 2ND FLR.
BRCS. HGT.
10'-0 3/4' 2ND FLR:
FIN. FLR —
8 -8 RS. HGT. _
P ENTRY
0 -0 IFIN.110
FLR
LEFT h"LEVATION
SCALE: 1/4 = I'-0' TEXTURED FINISH
RIGHT ELEVATION
SGALE: 1/4 = I'-0' TEXTURED FINISH
DOLLN
10ON
I-t OR
%LENT
2ND FLR.
HCsT.
3/4" 2ND FLR.
LR/5RG. HGT.
5RG. HGT.
TRY
" FIN. FLR.
® ■
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE,, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
0003325
�. V
4
:
Lu
uj
f'
N
cQ
a
N
�' fm
CREEKSIDE
LOT #72
PROJECT#
04321.200 072Rl
1%0L:
4EHB
' "2605-HAYDEN"
aARAGE SWING:
�I
RIGHT
RIGHT &
LEFT
ELEVATION "H"
60 MPH EXP.
ANC'e-1I T IEOT
STATE OF FLORID,,
OCT 17 2019 _
MICHAEL C. ANCtERSON
AR NO 17305
DATE- 10 14 19
SCALE: 1/4"=1'-0"
17TEET
FBI\\ =IAIIl
■
ELECTRICAL LEGEND
SYMBOL
DEFINITION
NOTES
125V OUTLET
20 AMP SINGLE POLE
110V OUTLET
110V OUTLET
0OF OUTLET WILD
TO SWITCH
110V OUTLET
EQUII-IGFI
INTERU D W/GRJD NTERUPTER (TAMPERER
RESISTANT TYPE)
220V OUTLET
(4) WIRE CONNECTION
I, WP
EXT. WATERPROOF
GROUND FAULT
GFI
OUTLET
INTERRUPTER
SWITCH
SWITCH
3-WAY OF ER.
I
I'
SWITCH
4-WAY OPER
�34
WALL MOUNTED
V.
LIGHT
CEILING LIGHT
O
LED GLG LIGHT
O VP
VAPOR PROOF
LIGHT
O
RECESSED CAN
_.n. ..
SCONCE
RE
W
VENT. FAN
1 CR`1 PER SQ FT.
VENT. FAN
W/LIGHT
I OR'1 PER SQ. FT.
VANITY LIGHT
FIXTURE
(SPEG'S TBD BY
BUILDER)
4'X2'
FLUORESCENT
WRAP
LIGHT
AROUND
AROUND
1_._. g
(RECESSED)
{{ �
TIC
4'X1'
FLUORESCENT
2-BI11-B WRAP
�'fl
LIGHT
AROUND
!SURFACE MNT.)
2' FLUORESCENT
4' FLUORESCENT
ppp
4' TRACK LIGHT
PANEL
METER
SMOKE DETECTOR
W1 HARDWIREUP
WALL MOUNTED
BATT. BACK-UP
SD.
SMOKE DETECTOR
W/ HARDWIRE
9/GOB
CARBON MONOXI
SMOI� DETECTOR
BATT. BACK-UP W/
HARDWIRE
INTER -CONNECTED
SHALL BE A DISTANCE
C421OF
NOT LESS THEN 4'
FROM WALL
'I
I PENDANT LIGHT
L�
NATURAL GAS
OUTLET
i
;TELEPHONE JACK
i
-1,
WAVER HEATER
IGNITION SOURCE
I DISCONNECT
TO BE ELEVATED
A/
AIR CONDITIONING
DISCONNECT
TV
TELEVISION JACK
CEILING BOX REQUIRED
O
J-BOX
TO BE SUPPORTED IN
ACCORDANCE W/ BOX
MARKED AS SUCH FOR
INSPECTION
CEILING BOX REQUIRED
TO BE SUPPORTED IN
CEILING FANLIGHT
ACCORDANCE W/ BOX
MARKED AS SUCH FOR
INSPECTION
24' INCANDESCENT
LIGHT STRIP
nn®
36' INCANDESCENT
LIGHT STRIP
nnnnnnnn
®
48' INCANDESCENT
LIGHT STRIP
_
FLOOD LIGHT
OPT. SECURITY
KP. -
KEYPAD
P8-
PUSH-BUTTON
FOR CHIMES
USB PORT
• LOCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS TO
BE VERIFIED • HOMEOWNER F'RE-CONSTRUCTION.
MEETING.
• ALL 15 4 20 AMP BRANCH. CIRCUITS TO BE ARCS FAJLT
PROTECTED PER ELECTRICAL PROVISIONS OF FBGR
6TH EDITION (2011 4 NEC 21012 2014 EDITIONL
• 20 AMP DEDICATED LAUNDRY CIRCUIT.
• GFI a ISLAND (NOT ON KITCHEN CIRCUIT)
• DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL
• BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF
50 CFM INTERMITTENT PER ELECTRICAL PROVISIONS OF
SECTION MIBO13 E=19 6TH EDITION (2011).
• LAUNDRYROOM RECEPTACLE SHALL BE GROUND
- FAULT CIRCWT-INTERRUPTER,PROTECTION FOR
PERSONNEL ON FEEDERS
• WIRING METHOD SHALL BE NONMETALLIC CABLE PER
ELECTRICAL PROVISIONS OF MOOR 6TH ED (2011).
• ALL WOW TO COMPLY WITH ELECTRICAL PROVISIONS
OF THE FBCR 6TH ED (2gi1)
• al I I AMPS SHALL BE SELECTED BY BUILDER AND
15% OF LIGHTING MUST BE ESERG=Y EFFICIENT TYPE PER
par- ENERGY CONSERVATION (RESIDENTIAL ENERGY
FFFICIfiNr-Y) 21211 6th EDITION 9404.1
n F FT
I I
COVERED
_,LANAI
CEILING MTD•
LIGHT TO i3E
INSTALLED,
UP I
PROVIDEGFI
OPT. FAN \
J-BOX FOR \
11-11
PRE -WIRED
DINING LIVING CLG FAN
ROOM ROOM
PRE -WIRED I-
45
CLG FAN
BDRM. #2
i I ,
L -- L SWITCH IN ,
CABINET / ��--------
OUTLET
_ /TO 2ND FL.
LU
R DWI SWITCH S/ O
q KITCHEN - BATH #2 III �L
r I I I I I
I
I
J FI 1 t TOR 1 ��
c'W , T
PAN. `\ �,. ( WH 1 �'
--- - t UFI • 44 CsFI a 44 S. FOR
Ar-A A.F.F. GARAGE
OPC GFI I S%CO i DOOR
/5OLLARP\�OND.
- - 1 AS REQ. �
t
PER HLDG.
/ ` \ CODI= rpm
FLEX ,/ i a
14111
K.EY LESS
FIXTURE
/� U4 METER
PRE -WIRED FOYER GFI 11 z VERIpD
GLG FAN I GARAGE LOC.
I DOOR
PREWIRE `,
L -U �� GARAGE IRRIGATION
.B: FOR 1
CHIMES \
�> \ Li L I� L
PORCH
OPT)COACH
LIGHT
FIRST FLOOR ELECTRICAL PLAN
SCALE: 1/4' = 1'-0'
----.-----__\
I = I
LED LIGHTING
SINGLE LAV.
BATH" 2
OUTLET
45' APP.
Will Panel MAIN -A
PANEL:. 8/16 wp crt. breaker VOLTAGE: 120/240 V-1Ph MAIN: 150 Amp M.C.B
FEEDER: 341 Cu THWN & 1-#6 Cu (G) in 1 12" C. OR 3-#2i0 AL THWN & 146 Cu (G) in 11/2" C.
Wire
Pole
Bkr
Description
Watts
Circuit
1
Circuit
Watts
Description
Bkr
Pole
Wire
#12
1
20 1
Exterior Receptacle GFI for TUG
1200
1
2
Space
#12
2
20
Irrigation Pump ..
1000
3
4
Space
5
6
6240
A/C C.U.
40
2 -
#8
SPace
7
8
PANEL -A
PAN E142 crt. breaker VOLTAGE: 120/ 240 V -1Ph MAIN: 150Amp M.L.O.
FEEDER: 3- #1 Cu THWN & 1- #6 Cu (G) in 1 1/2 C. OR 3- #2/0 AL THWN & 1- #6 Cu (G) in 1 1/2 C.
Wire
Pole
Bkr
Description
Watts
Circuit
Circuit
2
Watts
Description
Bkr
Pole
Wire
# 12
# 12
1
1
20
20
Small Appliance
1500
1800
1
8000
Range
50
2
#6
Microwme / Hood GFI
#12
1
20
Small Appliance
1500
5
6
4500
Water Heater
25
2
#10
#12
1
20
Refrigerator -
1500
7
8
# 12
1
20
Dining Receptacles AFCI
1500
9
10
1200
Disposal GFI
20
1 -
#12
#12
1
20
IBath GFI Receptacles
1200
11
12
1500
Dishwasher GFI
20
1
#12
#14
1
15
Foyer/ Flex /Hall AFCI
900
13
14
5000
Dryer GFI
30
2
#10
#14
1
15
1-Nng Rm, Lane!, Kitchen, bin. Us AFCI
900
15
16
Space
17
1500
Washer GFI
20
1
#12
#14
1
15
SD & C/O AFCI
900
19
1000
Garage Door Opener GFI.
20
1
#12
1
15
Space
Bedroom #2 / Bathroom #2 AFCI
21
23
1200
Garage Us & Receptacles GFI
20
1
#12#14
900
r22
900
Owners Suite AFCI
15
1
#14
#14
1
15
Bedroom #3 AFCI
900
25
900
Owners Bathroom AFCI
15
1
#14
#14
#12
1
1
-15
20
Bedroom#4/Opt. Bed#5/Opt. Loft AFCI
900
27
1200
1000
2nd Floor Hall/STO 2hd FL Liv./Laun. AFCI
20
1
#12
#12
Exterior Lights and Recept GFI
1000
28
Irrigation controls Only.
20
1
Space
31
32
Space
Space
33
34
Space
Space
35
36.
Space
Space
37
38
Space
#8
2
35
A/C A.H.U.
(Heater 5 KVA at 65%)
5525
39
40
Space
41
42
Space
Load subject to demand factor calculations / line
17600
2%500
Lo@d subject to demand factor calculations / line
Demand Factor Calculations:
ABBREVIATIONS:
AFCI: ARC FAULT CIRCUIT INTERRUPTER
NC: NON -COINCIDENT LOAD
GFI: GROUND FAULT INTERRUPTER
Total load subject to demand factor
45500
First 10000 watts at 100%
10000
Remaining watts at 40%
14200
Total A/C load
11765
LOAD CALCULATION IS BASED ON AIC NON -COINCIDENT LOAD I
Total Connected Load Watts
35965
Total Amps (watts/ 240 volts)
149.9
150 AMP ELECTRICAL RISER
NOT TO SCALE.
GENERAL NOTES:
A. ELECTRICAL MATERIALS AND INSTALLATIONS 844ALL
COMPLY WITH ELECTRICAL PROVISIONS OF THE POOR 6tH
EDITION (201-0 LOCAL CODES, AND ALL LOCAL POWER
COMPANY REQUIREMENTS.
B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS
NOTED OTHERWISE.
POWER COMPA
TRANSFORMER
GRADE
PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY
ELECTRICAL SERVICE. PROVIDE 34I COPPER (CU) IN
1-1/2" DIA SCHEDULE 00 PVC CONDUIT OR PROVIDE 3
0210 ALUMINUM (AL) IN 2" DIA SCHEDULE 00 PVC
CONDUIT UNLESS SERVICE IS PROVIDED BY THE
ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC
COMPANY PRIOR TO BID.
PROVIDE 342/0 CU, THWN • 1% OU IN 2' CONDUIT OR 3
'4/0 AL, THWN • 1% CU IN 2' CONDUIT.
(CONDUIT TO TERMINATE ABOVE SOFFIT • OVERHANG.)
COMBINATION SERVICE
DISCONNECT SWITCH AND
M ELECTRIC METER IN
NEMA 3R ENCLOSURE
150ARP
MCB
TELEPHONE SERVICE
ENTRANCE
E=IPMENT
INTERSYSTEM BONDING
TERMINAL AT LOW
VOLTAGE CONNECTIONS
150 AMP
D/240 VOLT
I PHASE
MLO
PANEL
CABLE TELEVISION
SERVICE ENTRANCE
EQUIPMENT
1 *4 CU SERVICE GROUND CONNECTED TO
CONCRETE ENCASED FOOTER STEEL PER
ELECTRICAL PROVISIONS OF THE FBCR &tH
EDITION (2011).
5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD
551 S. APOLLO BLVD..,
SUITE 202
MELBOURNE, FLORIDA32901
PH: 321-802-3591
Vvww.abd esi grigrou p.corri
AA #: 0003325
°I
VA
a tQ
w
W
rv"
9
0.
r4
Q
�
t
r'
m�
kP
n
(
'
i
Wo
W
t�
W
t'
4
:
r1 SBDI°V'.
CREEKSIDE
1 LOT #72
a
ROJECT# �+
04321.200 072R1
MODEL•
4EHB U
"2605—HAYDEN"
QARAQE SWING:
RIGHT
ka E
FIRST
FLOOR
N
ELECTRICAL
PLAN
160 MPH FBI'^
AHCH OTC
STATE OF FLORIDA
")CT 17 2019
Mill
PRINT
10 14 19
131 / /
SCALE: 1/4"=1'-0" 1
SHEET
E1
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
F
NA
W
D3
U
W
ti
F
c
V
v]
W
4
F
A
SVBDIV. & LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL
4EHB
"2605—HAYDEN"
GARAGE swlNc:
RIGHT
PAGE:
SECOND
FLOOR
ELECTRICAL
PLAN
160 MPH EXP. JC
ARCHrrECT
STATE OF FLORIDA
OCT 17 2019
AR NO 17305
T 14 10 19
/ /
FEC7,01AE: 1/4"=V-0]
SHEET
E 2
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
F
r
7 a
O
F
0.
214
h
W
C
F
A
rr
ti
iQYiiSS`� i56,.
SURDIV. �C "
v�
CREEKSIDE
u LOT #72
PROJECT*
j 04321.200 072R1
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
PLUMBING k
PLANS
60 MPH EXP.
ARCHrrECT.
STATE OF FLORIDA
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305
PRINT 14 10 19
DATE:
/ /
SCALE: 1/4"=1'-0"
SHEET
p1
f
10X6 4'
---
120 CFM FM 4
I
L
FLEX 10 12Xa GARAGE _
PASS
THRU
FOYER
lU
i
u u�- i
II
u
JI
PORCH
FIRST FLOOR
HVAC PLAN
SCALE. 1/4 = V-0'
R—VALUE SCHEDULE
FLOOR
SLA5 ON GRADE
R-0
EXTERIOR WALLS
CMU - INT INSUL
R-4.1
FRAMED WD - ADJACENT
R-13
FRAMED WD - EXTERIOR
R-13
CEILING
UNDER ATTIC
R-30
HA) -DEN EQUIPMENT SCHEDULE
4 TONS
MFG
CARRIER
G.U.
25H5C548As030@
A.H.U.
FX4DN(5,F)049L
HEAT
5 KW
SEER
15 SEER
TOTAL GAP
4-1500
ELECTRIC
208/230/I0H
SRKR
C.U.40 A.1-41135
REF LINES
-7/81, d 3/81,
?w'
x
ca
U
rq
W
F.
CIO
W
a
P.
F
A
{
CREEK:SIDE
LOT #72
i
PROJECT#
04321.200 072R1
IO EI :
4EHB
"2605-HAYDEN"
GARAGE SWING:
el
z,
RIGHT'
PAGE:
FIRST FLOOR
HVAC PLAN
160 MPH EXP. C
(PRINT 19 10 14
DATE: / /
SCALE: 1/4"=1' — 0"
SHEET
I�,a
w
23
U
O
F
ti
Cai
W
4
NE-
4
E:
ti
SIUBDIV. 8e LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL•
4EHB
2605- HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
SECOND
FLOOR
HVAC PLAN
60 MPH EXP. Cl
DATE 10/14/19
SCALE: 1/4"=1'-0"
SHEET
M2
PER FLR
PLAN
1/2' CLG.
1/2, DRYWALL
SECURE BT.
PLATE TO SLAB
W/ 10d MASONRY
NAIL e 32' O.G.
MAX
0'-0'
FIN. FLR.
nfv Tito al ATG
1SS
2x4 WOOD
STUDS 624'
O.G.
SLAE
NOTE: STUDS IN
PARTITIONS SUPPORTING
WALL HUNG PLUMBING
FIXTURES AND WALL
CABINETS SHALL BE NOT
LESS THAN 2x4, WHERE
SPACED NOT MORE
THAN 16 " O.C. OR, NOT
LESS THAN 2x6, WHERE
SPACED NOT MORE
THAN 24" O.G.
TYP. INT. WALL (NON-BRG.
SCALE: 3/4' = I'-O'
FIBERGLASS SHINGLES
OVER +'30 FELT PAPER
OR. SYNTHETIC
PRODUCT, INSTALLED
PER SECTION R905.1.1
ON a''O.S.B. SHEATHINGS
OR J' CDX PLYWOOD
SECURED PER
FASTENER SCHEDULE
PRE-ENG TRU65-
MTL. DRIP EDGE -
2x FASCIA PER —
ELEVATIONS
VENTED SOFFIT —
1/2' THICK, 2 COAT PORTLAND-J�
CEMENT PLASTER APPLIED
DIRECTLY TO MASONRY
0'-0' FIN. FLR
5/8' GYPSUM BOARD
OR 1/2' HIGH
STRENGTH CLG.
BOARD
PER ELE VAT I ON
_ SEE ENERGY CODE FORMS Fc
IN
R—VALUES
REFERENCE STRUCTURAL
I
0" PER ELEVATION
TYP- -
o-N- \
�R-4.1 INSULATION /
n WINDOW AT"i ACHMENT
SP PER MANUFACTURES
SPECIFICATIONS
/ STRUCTURAL
Ix2 P.T. FURRING—
STRIPS ®24' O.G.
8' GMU
1/2' GYP. WL. BD.—
WOOD BASE
f
5' DIA. SLEEVE,
DO NOT CUT
BOND BEAM -
SOLID GROUT
W/ CU- "5
(2) COURSE
DO NOT CUT
THE BOND
BEAM
REBARS
2A— PIPE THROUGH BOND BEAM
D1 SCALE:3/4'=1'-O'
FIBERGLASS SHINGLES
OVER *30 FELT PAPER
OR SYNTHETIC
PRODUCT, INSTALLED
PER SECTION R505.1.1
ON 116' O.S.B. SHEATHING:
OR i' CDX PLYWOOD
SECURED PER
FASTENER SCHEDULE
—REFERENCE
STRUCTURAL
PRE-ENG TRUSS
MTL. DRIP EDGE
2x FASCIA PER
ELEVATIONS
VENTED SOFFIT
1/2' THICK, 2 COAT PORTLAND
CEMENT PLASTER APPLIED
DIRECTLY TO MASONRY
I� I
n W/ WINDOW OPENING TYP. WALL SECTION
`' � NO OPENING NOTE:
PER SECTION 905.1.1 — FOR ROOF
SLOPES 2:12 TO LESS THAN 4:12, A
5 1-STORY HIP BLOCK WALL (2) LAYER UNDERLAYMENT SYSTEM
D1 SCALE: 3/4'=I'—O' 15 REQUIRED. FOR ROOF SLOPES
OF 4:12 OR GREATER, (1) LAYER
UNDERLAYMENT 15 PERMITTED BUT
MUST BE PER A5TM D226 TYPE [1,
ASTM D 4B69 TYPE Iv, OR ASTM D
675-1
CAULK AND SEAL
GAS LNE
I k PVC SLEEVE FOR GAS LINE
IQ' GYP. UL. BD.
WOOD BASE
2B GAS LINE THRU BLOCK
D 1 SCALE:
FIB LASS SHINGLES
OVER 0
30 LT PAPER OR
SYNTH IC PRODUCT,
INSTALLED R SECTION
R905.1.1 �' O.'51
SHEATHING O ' COX
PLYWOOD SECURE PER
FASTENER SCHE E
MTL. DRIP EDGE
2x FASCIA PER
ELEVATIONS
VENTED SOFFIT
PRE—ENG. GABLE TRUSS
WEEP SCREED
2x P.T. SECURED PER
STRUCTURAL DETAILS
1/2' THICK, 2 COAT
PORTLAND CEMENT
PLASTER APPLIED
DIRECTLY TO MASONRY
0'-0" FIN. FLR,L
8' CMU —
1-0'
TYP.
o-N.
1/2' THICK, 2 COAT -
PORTLAND CEMENT
PLASTER APPLIED
DIRECTLY TO
MASONRY
GALV. STEEL
TRACK BRACKETS
-
FASTENED TO
WOOD JAMB PER
PRODUCT
GALV. STEEL --
APPROVAL REa
VERTICAL TRACK 1' MIN.
BY MAUF. SLIDE
FASTENED TO
BRACKETS ROOM
W/ PRODUCT
APPROVAL REQ.
CORNER BEAD
a, CMU SEE
STRUCTURAL FOR
REINFORCEMENT
2xFi P.T. WD
ATTACHED TO FILL
CELL AS PER
PRODUCT
APPROVAL ISO.
SEALANT
BACKER ROD
WEATHER STRIP
MOULDING ALL
AROUND (BY
DOOR MANUF.)
OVERHEAD DOOR
BY OTHERS
3 ) GARAGE DOOR JAMBS
D1 SCALE: 11/2"=1'—O'
2x BLOCKING BETWEEN TRUSSES
PER STRUCTURAL DETAILS —\
-STIFFBACK AT ALL UPRIGHTS —
PER STRUCTURAL DETAILS
-PRE-ENG WO. TRUSS
PER ELEVATION
CONT. 2x RAT RUN SECURED PER
STRUCTURAL DETAILS
SEE ENERGY CODE FORMS FOR -
INSULATION R-VALUES
PER ELEVATION
5/8' GYPSUM BOARD OR 1/2'—
HIGH STRENGTH CLG. BOARD
R-4.1 INSULATION
WINDOW ATTACHI'
ix2 P.TNkI
STRIPS
1/2' GYP.
W� B.
FI53~RGLASS SHINGLES
OVER N30 FELT PAP OR
SYNTHETIC PRODU ,
INSTALLED PER CTION
R92a5.1.1 ON .5.5.
SHEATHING J' CDX
PLYWOOD EGURED PER
I'-0 FASTEN SCHEDULE
TYP. MTL. RIP EDGE
2 ASCIA PER
EVATIONS
VENTED SOFFIT
PRE—ENG. GABLE TRUSS
WEEP SCREED
—2x P.T. SECURED PER
STRUCTURAL DETAILS
A W WINDOW PENING B TYP. WALL SECTION
NO OP NG
�1-STORY GABLE BLOCK WALL
SCALE: 3/4' = I' -O'
1/2' THICK, 2 COAT
PORTLAND CEMENT
PLASTER APPLIED
DIRECTLY t0 MASONRY
CMU
0'-0' FIN. FLR
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www. abdesigngroup.com
AA #: 0003325
h
w
U
w
F
0.
D3
W
4
F
q
x
ti
SLJBDIV. 8o LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
DETAILS
�60 MPH a C
ARCHrrECT-
STATE OF FLORIDA
OCT 17 2019
MICHAEL C. ANDERSON
AR NO T7305
PRINT DATE-
10 14 19
SCALE: 1 /4"=1' — 0"
SHEET
1) 1
FIBERGLASS SHINGLES
OVER 030 FELT PAPER
OR SYNTHETIC
PRODUCT, INSTALLED
PER SECTION RS05.1.1
ON J' 0-9.8. SHEATHING
OR J' CDX PLYWOOD
SECURED PER
FASTENER SCHEDULE
PRE-ENG WD.TRUSS-
24' O.C. MAX.
METAL DRIP EDGE--`
2x FASCIA PER -
ELEVATIONS
VENTED —
SOFFIT
REFERENCE -
STRUCTURAL
1/2' THICK, 2 COAT
PORTLAND CEMENT
PLASTER APPLIED
DIRECTLY TO
MASONRY
IX2 FIRE -STOP
SEE STRUCTURAL
IX2 FIRE -STOP
1/2' THICK, 2 COAT
PORTLAND CEMENT
PLASTER APPLIED
DIRECTLY TO
MASONRY
IX2 FIRE -STOP
O.H.
H
Q
w
w
w
w
(L
ly
E
LEVATION
R-30 INSULATION
PER ENERGY
CODE FORM.
5/8' GYPSUM BOARD
OR In' HIGH STRENGTH
CLG- BOARD
Ix2 FIRE -STOP
-R-4.1 INSUL.
WINDOW ATTACHMENT
AS PER
MANUFACTURES
SPECIFICATIONS
STRUCTURAL
3/4' T 4 G SUBFLOOR
GLUED AND NAILED
AS PER NAILING
SCHEDULE
�MEV_AT_ION
ER
LEVATION
FIBERGLASS SHINGLES
OVER 030 FELT PAPER
OR SYNTHETIC
PRODUCT, INSTALLED
PER SECTION R905.1.1
ON J' O.S.B. SHEATHING
OR }' CDX PLYWOOD
SECURED PER
FASTENER SCHEDULE
PRE-ENG WD.TRUSS
—
24' O.G. MAX.
METAL DRIP EDGE)
2x FASCIA
ELEVATIONS
VENTED—�
SOFFIT
REFERENCE
STRUCTURAL
1/2' THICK, 2 COAT
PORTLAND CEMENT
PLASTER APPLIED
DIRECTLY TO
MASONRY
IX2 FIRE -STOP
SEE STRUCTURAL
5/8' GYPSUM BOARD
OR 1/2' HIGH STRENGTH CLG.
BOARD
LEVATION
IX2 FIRE -STOP
R-4.1 INSUL.
WINDOW ATTACHMENT AS PER
MANUFACTURES SPECIFICATIONS
REFERENCE STRUCTURAL
1x2 P.T. FURRING
STRIPS a 24' O.G.
8' CMU
1/2' GYP. WL. BD.
WOOD BASE
1/2' THICK, 2 COAT
PORTLAND CEMENT
PLASTER APPLIED
DIRECTLY TO
MASONRY
1X2 FIRE -STOP
si
GRp,Ai:
SINE ,
R-30 INSULATION
PER ENERGY
CODE FORM.
5/8' GYPSUM BOARD
OR 1/2' HIGH STRENGTH
CLG. BOARD
Ix2 FIRE -STOP
4.1 INSUL.
3/4' T 4 G SUBFLOOR
GLUED AND NAILED
AS PER NAILING
0m SCHEDULE
L
w
w m *LPE�I_ATION
R
LE VAf1ON
5/8' GYPSUM BOARD
OR 1/2' HIGH STRENGTH
CLG. BOARD
R-4.1 INSUL.
Ix2 P.T. FURRING
STRIPS ,111) 24' O.G.
8' CMU
1/2' GYP. WL. BD.
WOOD BASE
ti W/ WINDOW OPENING n WITHOUT WINDOW OPENING
2-STORY FIRST FLOOR BLOCK
SECOND FLOOR BLOCK
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE. FLORIDA32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
E
w
U
w
4
4
a
G
W
Q
Ewr
Q
E
ti
BUBDIV. 8e LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072RI
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
DETAILS
U MPH EXP. JC
ARCHrrECT-.
STATE OF FLORIDA
k4At__�
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305
=3RI 10/14/19
S CALF: 1 /4"=1' — 0"
SHEET
D2
SCALE: 3/4' =1' -0'
SECURE 2x6 MIN. TO BLK W/ (2)AIX8' A -BOLTS 4' EMBEDMENT MIN.
W/ 21XVA WASHER AND NUT SPACED EVENLY FROM FLOOR T(
GARAGE DOOR H I'�I IN�PRIOR TO FILL(
■m
'SECURE 2x4 ONE
FLAT TO BLK
W/ GUT NAILS.
SIDES:
2X6 GARAGE DOOR BUCK W/ (5)
J51XBF A -BOLTS 4' EMBEDMENT MIN.
W/ 21X21X16 WASHER AND NUT
SPACED EVENLY FROM FLOOR TO
GARAGE DOOR HDR IN JOINTS
PRIOR TO FILLING.
1-2X6 PT BLOCK • CENTER OF
DOOR HEADER W/(1)Y1'XS' J-BOLTS
4' EMBEDMENT W/ 2'X21X1%' WASHER
AND NUT.
E
-' (NOTES: I J
ALL ANCHORS SHALL BE IN ACCORDANCE TO
MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERI
SUCH INSTRUCTIONS ARE MORE STRINGENT
GARAGE DOOR
1 BUCK ATTACHMENT
D3 1 ScAi-r, W-P-®,
2X4=
2X4=
SECURE TO BLOCK W/ 3f6'
2X4=
SECURE TO BLOCK W/)/4'TAPCONS
(MIN. SHANK SIZE
SECURE TO BLOCK W/ W%
TAPCONS(MIN. SHANK SIZE
.145
TAPGON5
MIN. HEAD SIZE 300
(MIN- SHANK 51ZE .145
.145
MIN. HEAP SIZE 300
8' GMU
MIN. EMBEDMENT 1 Y4')
WITHIN 8' OF EACH END 4
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 Y4)
MIN. EMBEDMENT I Y4')
NOTE: STRUCTURAL 2X
lV DRYWALL
16" O.G. MAX SPACING.
NOTE: STRUCTURAL 2X
WITHIN B' OF EACH END 4
NOTE: STRUCTURAL 2X
WITHIN 8' OF EACH END 4
N OUTSIDE 4
1'X4" OR 1'X2' P.T. NAILER
2X6
MUST BE ON OUTSIDE 4
18' O.G. MAX SPACING.
MUST BE ON OUTSIDE 4
18 O.G. MAX SPACING.
SECURED ROUGH
lx4 P.T. OR 5/4'X4' MIN.
SECURE TO BLOCK W/2- 6'
SECURED THROUGH
NON-STRUCTURAL 3�i6'
2X6om
SECURED THROUGH
2X6:®
SECURE
3♦
NON-STRUCTURAL 6
SECURE tHRU FRAME 4
TAPCONS
TAPCON MIN- 1-Y4
SECURE TO BLOCK W/2-3if6'
NON-STRUCTURAL WW
TO BLOCK W/1-1/4
TAPCON5(MIN. SHANK SIZE
TAPCON MIN. 1-Y4'
EXTEND 1-Y4' INTO BLOCK
(MIN. SHANK SIZE -145
EMBEDMENT INTO BLOCK.
TAPCONS
TAPCON MIN. I-Y4'
EMBEDMENT INTO BLOCK
-145
EMBEDMENT INTO BLOCK.
W/ 3X,&' TAPCONS
MIN. HEAD SIZE .300
8 GMU
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
❑
(MIN. SHANK SIZE .145
MIN. EMBEDMENT I Y4')
Yz DRYWALL
MIN. HEAD SIZE 300
8' CMU
MIN. EMBEDMENT I Y4')
„
8 CMU
MIN. HEAP SIZE 300
WITHIN 8 OF EACH END 4
MIN. EMBEDMENT 1 Y4)
'DRYWALL
WITHIN 8' OF EACH END 4
�i" DRYWALL
MIN. EMBEDMENT I-Y4 '
WITHIN 8 OF EACH END 4
18' O.G. MAX SPACING.
2X8:®
❑ TI'X4'OR VX2' P.T. NAILER
WITHIN 8' OF EACH END 4
18 O.G. MAX SPACING.
1'X4 OR I X2 P.T. NAILER
18 O.G. MAX SPACING.
❑ 1'X4' OR I'X2" P.T. NAILER
2X8cm
2X8
18' O.G. MAX SPACING
SECURE TO BLOCK W/2-346'
N6' OS$.:+C 4' MIN.
SECURE TO BLOCK W/1-1/4 '
Xb' O.SB.
TAPCONS
SECURE TO BLOCK W/2-Wib'
X 4' MIN.
DOOR CASING
(MIN- SHANK SIZE .145
DOOR CASING
TAPCONS
DOOR CASING
TAPCONS
(MIN. SHANK SIZE
POOR CASING
DOOR JAMB OR WINDOW
MIN. HEAD SIZE 300
MIN. I Y4')
DOOR JAMB OR WINDOW
(MIN. SHANK SIZE .145
MIN. HEAP SIZE 300
.145
MIN. HEAD SIZE 300
ATTACH TO 2X PER
EMBEDMENT
WITHIN 8 OF EACH END 4
ATTACH t� 2X PER
DOOR JAMB OR WINDOW
MIN. EMBEDMENT 1 Y4')
DOOR JAMB OR WINDOW
MANUFACTURES DETAILS.
18 O.G. MAX SPACING.
MANUFACT'URES DETAILS.
WITHIN 5" OF EACH 4
ATTACH t0 2X PER
WITHIN 8' OF EACH END 4
ATTACH 70 2X PER
NOTE: SHIM AS NEEDED TO PLUMB JAMB
NOTE: SHIM AS NEEDED TO PLUMB JAMB
IVO.C. MAX SPACING.
MANUFACTURES DETAILS-
18 O.C. MAX SPACING.
MANUFACTURES DETAILS.
(DO NOT EXCEED Y4')
(DO NOT EXCEED Y4')
NOTE, Swim AS NmPED To PLAAt81 JAm (oo NOT Do=p )s')
NOTE. 84r A8 WM=
TO PU M JAM (PO NOT r=MP V)
DOOR JAMB TO BLOCK +3/4 OR +5/4
DOOR JAMB
TO BLOCK +1-15//16"
DOOR JAMB TO BLOCK +T
DOOR JAMB TO BLACK +3-7/16"
A WINDOW TO
BLACK +3/4 OR +5/4
C WINDOW TO BLACK +1-15/16" —
E WINDOW TO BLACK +3"
G WINDOW TO BLACK +3-7/16"
SCALE: N.T.S.
SCALE: N.T.S.
SCALE: N.T.S.
SCALE: N.T.S.
2X4=
2X4: ®
2X4:®
SECURE TO BLOCK W/
2X4:m
SECURE TO BLOCK W/ Wg,
SECURE TO BLOCK W/ W,&'
TAPGON5
SECURE TO BLOCK W/Y4'
TAPCONS OR
TAPCONS
(MIN. SHANK SIZE .145
TAPCONS
(MIN. SHANK SIZE .145
(MIN. SHANK SIZE -145
MIN. HEAD SIZE 300
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. HEAD SIZE 300
MIN. EMBEDMENT I Y4 )
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 Y4')
MIN. EMBEDMENT 1 Y4')
WITHIN 8' OF EACH END 4
NOTE: STRUCTURAL 2X
MIN. EMBEDMENT I V4')
WITHIN 8' OF EACH END 4
WITHIN 8' OF EACH END 4
NOTE: STRUCTURAL 2X
IS" O.G. MAX SPACING.
MUST BE ON OUTSIDE 4
WITHIN 8' OF EACH END 4 NOTE: STRUCTURAL 2X
18' O.C. MAX SPACING.
15' O.G. MAX 5PACING.
MUST BE ON OUTSIDE. 4
2X6:®
SECURED THROUGH
18' O.C. MAX SPACING. MUST BE ON OUTSIDE 4
2X6:®
2XScm
SECURED THROUGH
SECURE TO BLOCK W/2-%'
NON-STRUCTURAL W6'
2X6mm SECURED THROUGH
SECURE TO BLOCK W/2-3f,&
SECURE TO BLOCK W/2-%.'
NON-STRUCTURAL 3r6'
TAPCONS(MIN. SHANK SIZE
TAPCON MIN. 1-Y4"
SECURE TO BLOCK W/1-1/4' NON-STRUCTURAL -%`
TAPCONSCMIN. SHANK SIRE
TAPCONS
MIN.
145
EMBEDMENT INTO BLOCK
TAPCONS TAPCON MIN. I-Y4
EMBEDMENT INTO BLOCK.
.145
(MIN. SHANK SIZE .145
IN.SHANK
EMBETAPCDMENT INTO
EMBEDMENT INTO BLOCK.
MIN. HEAD SIZE 300
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
MIN- HEAD SIZE 300
MIN. EMBEDMENT 1 Y4')
8 GMU
MIN. HEAD SIZE 300
MIN. EMBEDMENT I Y4')
MIN. EMBEDMENT I Y4')
WITHIN 8' OF EACH END 4
DRYWALL
MIN. EMBEDMENT 1 Y4')
8' GMU
WITHIN 8' OF EACH END 4
8 GMU
��
WITHIN 8 OF EACH END 4
8' GMU
V
18' O.G. MAX SPACING.
I'X4' OR I'X2" P.T.NAILER
WITHIN 8' OF EACH END 4
,
DRYWALL
18' O.G. MAX SPACING.
J�" DRYWALL
18 OC. MAX SPACING.
DRYWALL
I'X4' OR I'X2' P.T. NAILER
2X8:®
2ND 2X SECURE TO
18 OG. MAX SPACING.
1'X4' OR I'X2' P.T. NAILER
❑
2X8:®
1'X4' OR 1' P.T. NAILER
❑
DOOR CASING
SECURE TO BLOCK W/2-%'
TAPCONS(MIN. SHANK SIZE
r,,,5TRUCTURALMEMBER
2X8csm
SECURE TO BLOCK W/1-1/4'
P.T. X 4' MIN.
SECURE TO BLOCK W/2-V
1N
DOOR CASING
SECURE
SECURE t0 BLOCK W/2-3i(6'
145
/(2)12d WITHIN 8' OF EACH
TAPCONS
DOOR CASING
TAPCONS
TAPCONS
(MIN. SHANK SIZE
MIN. HEAD SIZE 300
ND 4 6' TO 8° O.C. MAX
(MIN. SHANK SIZE .145
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
DOOR JAMB OR WINDOW
.145
MIN. HEAD SIZE 300
DOOR JAMB OR WINDOW
MIN. EMBEDMENT 1 Y4')
OOR CASING
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 Ya')7w
ATTACH TO 2X PER
MIN. EMBEDMENT I Y4')
ATTACH TO 2X PER
WITHIN 8" OF EACH END 4
18' O.G. MAX SPACING.
DOOR JAMB OR WINDOW
ATTACH TO 2X PER
MIN. EMBEDMENT 1 Y4')
OOR JAMB OR WINDOW
DTTACH
WITHIN 8' OF EACH END 4
MANUFACTURES DETAILS.
WITHIN 8" OF EACH END 4
MANUFACTURES DETAILS.
MANUFACTURES DETAILS.
WITHIN 8' OF EACH END 4
IS' O.C. MAX SPACING.
TO 2X PER
18' O.G. MAX SPACING-
IV D.C. MAX SPACING./4
MANUFACTURES DETAILS.
NOTE: SHIM AS NEEDED TO
PLUMB JAMB (DO NOT EXCEED Y4')
NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4')
NOTE: SHIM AS NEEDED TO
PLUMB JAMB (DG NOT EXCEED Y4')
NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4')
DOOR JAMB
TO BLOCK +1-1/2"
DOOR JAMB TO BLOCK +2 1/4"
DOOR JAMB TO BLOCK +3"
DOOR JAMB
TO BLOCK +3 3/4"
WINDOW
B
TO BLOCK +1-1 2
WINDOW
TO BLOCK +2 1/4TO BLOCK +2 1/4"
F' WINDOW TO BLOCK +T
i1 WINDOW TO BLOCK +3 3/4"
11
SCALE: N.T.S.
SCALE: N.T.S.
SCALE: N.-I
SCALE: N.T.S.
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
Iu
W
DI
0
F
U
r
F
A
ti
SVBDIV. 8e LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
DETAILS
60 MPH EXP. C
ARCHfTECT:
STATE OF FLORIDA
OCT 17 2019
MICHAEL C. ANDERSON
iIIIN AR NO 17305 oi
PRINT 10 14 19
DATE:
SCALE: 1/4"=1'—O"
SHEET
D3
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
N
113
U
W
4
U4
�F
y A
I
A�
g'
t'
SUBDIV. & LOT:
i$
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
DEz+
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
WALL
ASSEMBLY
DETAILS
60 MPH EXP. JC
ARCHITECT
TATE OF FLORIDA
OCT 17219
MICHAEL C. ANDERSONk N
AR NO 17305
DATE 10/14/19
SCALE: 1/4"=1'-0"
SHEET
LEGEND
DRAINAGE PLANE (WRS
LATER #1, STUCCO WRAP)
WRB LAYER *2 (FORTIFIBER
5UILDING PAPER)
METAL LATH
;Q0��
X—X—X—X
WOOD SHEATHINCx
OR 1/16" ZIP SHEATHING SYSTEM
( INSTALLED PER MANUF. SPECS.)
SELF-ADHESIVE FLASHING - - ---
NOTE:
METAL LATH: LATH TO BE PER SECTION
R-103.1.1 / ASTM C-84-1-mc3, MIN. 2.5 LBS.
PER SQ. YARD (UTILITY OR NOMINAL
LATH DOES NOT MEET SPECIFICATIONS)
STUCCO
FINISH
6' SELF ADHESIVE
OVER TOP E SIDES
SELF
FLASHING
UNIT
PREMANUF- DRYER
VENT GAP (SET IN
CONT. SEALANT)
SEALANT 8
TOP E SIDES
6B DRYER VENT (BLOCK)
BUILDING PAPER
OVER 'QUICK
FLASH'
PIPE THROUGH
WALL
L SELF ADHESIVE
FLASHING (INSTALL
PER MANUF. SPECS-)
BUILDING PAPER —
UNDER 'QUICK FLASH'
/ NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
A VENT PENETRATION
SCALE: N.T.S.
ELEG. METEF
VERIFY LO
AK A I V K>=C,=IYl=
STUCCO SCRATCH COAT
E 1 GOAT OF PAINT W/BACK-
ROLL PRIOR TO
ELEC. METER INSTALLATION
ELEC. METER FIELD
VERIFY LOCATION
APPLY STUCCO SCRATCH GOAT
AND ONE (1) LAYER OF PAINT
PRIOR TO INSTALLING ELEC.
METER
CAVITY TO BE FILLED
WITH RIGID POLYMERIC
ISOCYANOTE-POLYBLEND FOAM
("GREAT STUFF" OR SIMILAR)
APPLY A SILICON
BASE SEALANT AT POINT
THAT ELEC. WIRE PENETRATES
PROVIDE STUCCO SCRATCH
COAT LARGER THAN THE ELEC.
METER GAN OR METER CAN
COMBO OR METER CAN AND
DISCONNECT
ELECTRICAL, CONDUIT_
PENETRATION
WRB LAYER "I,
CUT OPENING IN STUCCO WRAP
APPROVED HOUSEWRAP
FOR SOX INSTALLATION
LAYER 01,
ujR5
WRAP I9- MEMBRANERSTUCCO FLASHING
APPLY SELF -ADHERING
MEMBRANE FLASHING
WOOD SHEATHING OVER BOX AND OVER
APPROVED WRSLAYER
STEP #1
APPROVED
HOUSEWRAP
BELOW
CUT SUCH TPA'
NO MEMBRANE
ENTERS BOX,
APPLY TO FA(
EDGE
APPLY E-Z SEAD—
OVER 60 MIN
GRADE: 'D,
FELT -PROVIDE
SEALANT AT ALL
JOINTS AND
INTERSECTIONS
5TF 1*3
.o.o. e.o
p •O.O.O ,
•O O.
,. o
.O O.
o. .o
O O.
O. .O
o ,.
o.
0 0.
; •O.O.O G
STEP #2
APPLY 60 MIN
GRADE 'D' FELT
OVER
SELF -ADHERING -
FLASHING OVER
APROVED
HOUSEWRAP
WRB LAYER 01,
STUCCO WRAP
SELF -ADHERING
MEMBRANE: FLASHING
WRB LAYER 02, FORTIFIBER
BUILDING PAPER
STET *4
ELASTOMERIC
COATING OVER
STUCCO/ G.V. FINISH
(SEE TYPICAL WALL
SECTION)
METAL LATH
STEP *5 STEP #(a
OELECTRICAL RECEPTACLE
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
IlIka AA #: 0003325
F
w
U
W
4 h
0.
v
0
F
Q
ti
SUBDIV. & LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
WALL
ASSEMBLY
DETAILS
60 MPH EXP. C
ARCHRECT:
STATE OF FLORIDA
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305
DATE: 10/14/19
SCALE: 1/4"=1'-0"
SHEET
LEGEND
DRAINAGE PLANE (UJR5
LA4'rER #1, STUCCO UJRAP)
UJRB LATER *2 (FORTIFIBER
PUILDING PAPER)
METAL LATH
5TU000
UJ001D SHEATHING
OR 1116" ZIP SHEATHING SYSTEM
(INSTALLED PER MANUF. SPECS.)
SELF—ADHESIVE FLA6HING
2 1/211
x x
L—__
CORNER BEAD
(FASTENER 4 SPACING a 7" O.C.)
NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
CMU
5/8" THICK, 3 COAT CEMENT
PLASTER APPLIED
DIRECTLY TO MASONRY
14]3LORNER BEAD C BLOCK
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
ti
W
C
W
o
U
Iw
I
I
ti
@
u
3
a
O
Z
1 LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL:
4EHB
"2605—HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
I
WALL
ASSEMBLY
DETAILS
60 MPH EXP. C
ARCHrrECT
STATE OF FLORIDA
r
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305
PRINT 10 14 19
DATE- / /
SIC AT 1/4"=V-O'
SHEET
l
I
I
I
t1 `
s �
2x6 SUB -BAND
W/1 "x4" NOTCH 6
END, WRAPPED IN
PE1=L 8 STICK
DRIP EDGE
1/8" TEXTURED
FINISH -a WOOD
1/2" TEXTURED
FINISH a CMU
METAL FASCIA
WRAP Yap FROM
STUCCO, 1" FRO
WOOD WALL
\�� EXTERIOR WALL
o (FRAME OR CMU
NOTE: NOTCH FOR 2X6
SUB SAND ONLY
�\ I
A)ELEVATION
METAL FA
2X6 SUB I:
m
ROOF KICK OUT REMOVED
\\ FOR CLARITY
� ROOF DECK (5EYOND)
-\DRIP EDGE, 1" OFF WALL
(NOT INTO STUCCO)
11/8" TEXTURED FINISH 10
WOOD, 1/2' TEXTURED
/
/ FINISH Q CMU
��2xro SUB -BAND W/I"x4" NOTCH
END, WRAPPED IN PEEL 4 STICK
METAL FASCIA WRAP 1" OFF
WOOD WALL. SUB BAND 2"
OFF WOOD WALL
1/8' TEXTURED
FINISH w WOOD,
1/2' TEXTURED
FINISH a CMU
METAL LATH
WOOD SHEATHING
OR CMU
WR5 LAYER *i,
STUCCO WRAP (FRAME ONLY)
WRB LAYER 02, FORTIFISER
BUILDINGS PAPER
(FRAME ONLY)
ROOFING CEMENT
DRIP EDGE
METAL KICK OUT
NOTE: I
IF ZIP SHEATHING
PLEASE SEE 1`1Al
PROGEDURES
PRE-ENG'D TRUSS TO BE CUT 6
WALL LINE TO AVOID CONTACT
W/TEXTURED FINISH
2 "x4 "x4' - m"
SCABBED TO TRUSS
W/126 NAILS ro'-8"
O.G. MAX.
2x SUB -BAND W/lY"x4"
NOTCH o END
METAL FASCIA WRAP
DRIP EDGE
EXTERIOR WALL
(FRAME OR CMU)
SUB BAND DETAIL 0) WALL
SUB BAND DETAIL OP WALL
W/KICK-OUT
FRAME OR CMU
FELT PAPER
DRIP EDGE
(REFERENCE POINT
ONLY, FOR WALL OFF
SET OF COMPONENTS)
METAL FLASHING, WRAPPED
MIN. Y4" ABOVE BOTTOM OF
DRIP EDGE
2x SUB -BAND
W/12"x4" NOTCH a
END, WRAPPED IN
PEEL 4 STICK
*ROOF CEMENT .9
ROOF EDGE
OMITTED FOR
CLARITY
FRAME OR CMU
WALL KICK -OUT FLASHING
FELT PAPER
DRIP EDGE
(REFERENCE POINT
ONLY FOR WALL OFF
SET OF COMPONENTS)
METAL FLASHING, WRAPPED
MIN. ,V4" 45OVE 50TTOM OF
DRIP EDGE
2x SU5-5AND
WIV22"x4" NOTCH a
END, WRAPPED IN
PEEL 8 STICK
*ROOF CEI 1r_NT a
ROOF EDGE-
OMITTED FC,R
CLARITY
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
F
w
w
ti
a
w
4
F
A
SvBDIV. 8e LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL:
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
PAGE:
WALL
ASSEMBLY
DETAILS:
SUB -BAND
60 MPH EXP. C
ARCHffECT
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305
r"ir' a 190 114
DATE: / /
SCALE: 1/4"=1'-0"
SHEET
WA6
r
�jl
f1,
III
j
a
f,' I
I 39'-8'
101-01, v 27-10"
j,
4„ T
�a
�A LJ
FM 12X18
d I ao co I o
L IN N
au
g 4" CONC.
ILL O w SLAB LL
I 3
_j LL
n
L' U LJ GJ UI C
— — — — — — F M -16 x 18 — — — — — — — — —
1 4
¢rv{ 10 '0„ 11'-8" 15' 4„ JID
IO OD 0 0,0„ v,� TfiPOF
I� SLAB JQ o wNU O20' 5" cv
N
`t 7'-51,
LL
9
1_ CW-12x12 1.1
s � --
°°
cJ
ii
L
8
op
ul
4A00
p
cr i i
F-2 x24
11
(
o
M
N
���z
II
CWC-12x1`2'
x
N
OD
"`yw
Lu
LL
OD
4" VC
,..
"�
CD
d'
A
<OD
I
U II U
I
�
UP TO 2ND FLOOR
iv
��
" 6"
0 At
a II J :
I
(FIELD VERIFY
CH
SE
�� `
I
3'
I
= 11 w
8
EXACT LOCATION)
5
`
`
r
O
O
II
y I
I
1.4
1.1
T+
TOP OF
�
.p SLAB
9' -
-
9'-0"
2'-8"
9' 4"
o
O
1
1.1
NI
CV
#3 TRANSFER STEEL
�I
a0
@ 24' O.C. MPX
cal
I
-'
N
°°
So
2
0'-0' FIN. EL V. "
I
`cm
1.1
ao
FIN. CONC. LAB
(X
x
o
4
�`LL
L
FM+16x18
OD
4
9 -�T-6„
ull
1.1
co00
b?
x
r o
N .
4"CO CIp
FM 16x18w
aSLAB
1
n L
FM-12x18
rr
I'
N
'-4"
101-01, 4„
6,4„
20'4„
18 oll
39'-8"
FOUNDATION PLAN
FOUNDATION NOTES
1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR
COMPACTING REQUIREMENTS.
2. TOP OF FINISHED SLAB SHALL BE +4-0".
3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED
OTHERWISE.
4. REFERENCE ELEVATION +4-0", SEE SURVEY PLOT FOR NGVD.
5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN
TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS
ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER
SERVICES.
6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE:
PROVIDE 1/2" FELT PAPER AT THE JOINT,
7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH AR@HITECTURAL
DRAWINGS.
8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING.
9.- WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE
WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITEGTURAL DRAWINGS
AND WITH THE MANUFACTURES SPECIFICATIONS.
10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT:
11:MIINDICATED #5 BAR, OINDICATES #6 BAR,■INDICATES #7 BAR VERTICAL
REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF BARS SHALL BE
HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN AbI STANDARD 900
HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS.
12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 5AR DIAMETERS (#5 =
30", #6 =36"), AND REINFORCING SHALL BE CONTINUOUS:
13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL
REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE
SOIL BEARING CAPACITY OF 2,000 PSF, TRANSFER REINFORCINQ (TOP STEEL) HAS
BEEN DELETED UNLESS NOTED OTHERWISE.
14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS
OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE:
A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION
C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS
15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, BUILDING
CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY.
CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, USING: F'm =
1,50 PSI, TYPE 'M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN
RUNNING BOND.
16, WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER 3 OF SLAB SUPPORTED
3-0" O/C MAX. SEE PLAN FOR WWM SIZE.
INSPECTOR NOTE:
1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING
CODE, RESIDENTIAL, 6th EDITION
SLAB SCHEDULE
SLAB
THICKNESS
REINF.
REMARKS
T6x61.4xW1.4OVER
GENERAL
3 112"MIL
VAPOR
COMPACTED FILL
BARRIEF(r
FOOTING
PROVIDE CORNER BARS, SAME SIZE QUAN I BARS SCHEWITHDULE FOUNDATION, OCEG EACH WAY.
MARK WIDTH LENGTH' THICKNESS BOTTOM REINF. TOP REINF. T.O.F.
SHORT LONG
FM-12x18 12' CONTINUOUS 181, (2) #Ss (+)0'-0"
FM 16x18 16' CONTINUOUS 181, (2) #5's (+)0 0" -
FM 20xl8 20" CONTINUOUS 18" (2) #5's (+)0 0"
FMC-16z18 16" CONTINUOUS 18" (2)#5's VARIES
CW-12x12 12" SEE PLAN 12" (2) #5's (+)0"-0"
CWC-12x12 12" SEE PLAN 12" (2) #5's VARIES
F-2424 24" 24" 12" (2) #5's 1 (2) #5's (+)0" 0"
TE-1 8" SEE PLAN 8" - (1) #5's (-)0"-4"
NOTE: WELDED WIRE MESH &
VERTICAL REBAR NOT
SHOWN FOR CLARITY
#3 TRANSFER STEEL @ 24" O.C. MAX ON 1 1/2"
CHAIRS @ FOUNDATION SLAB & WIRE TIED
TO CONTINUOUS FOOTER STEEL
+
TOP OF
A/C 51MPSON IUB
UNIT ROLL STRAP
OR EQUAL
EACH CORNER
11 OF UNIT
--- wrvc.— SECURE STRAP TO
SLAB UNITS LU/ (2) "8x1 1/4
< SUPPORT #3 W/1 1/2" CHAIRS SHIT MTL SCREWS
ti
A�TRANSFER STEEL INSTALLATION
SCALE: 3/4"=V-0"
SECURE
STRAP TO
GONG- W/
(2)-3/I6'X2'
TAP -CONS
A/C CONNECTION
TO PAD :DETAIL
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA3290J
PH: 321-8023591
www.abdesigngroup.com
AA #: 0003325
NOTE: WELDED WIRE MESH &
VERTICAL REBAR NOT
SHOWN FOR CLARITY
#3 TRANSFER STEEL @ 24" O.C. MAX ON 1 1/2"
CHAIRS @ FOUNDATION SLAB & WIRE TIED
TO CONTINUOUS FOOTER STEEL
+
TOP OF
A/C 51MPSON IUB
UNIT ROLL STRAP
OR EQUAL
EACH CORNER
11 OF UNIT
--- wrvc.— SECURE STRAP TO
SLAB UNITS LU/ (2) "8x1 1/4
< SUPPORT #3 W/1 1/2" CHAIRS SHIT MTL SCREWS
ti
A�TRANSFER STEEL INSTALLATION
SCALE: 3/4"=V-0"
SECURE
STRAP TO
GONG- W/
(2)-3/I6'X2'
TAP -CONS
A/C CONNECTION
TO PAD :DETAIL
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA3290J
PH: 321-8023591
www.abdesigngroup.com
AA #: 0003325
17
4
�
s
Lu
ul
'1
�
I'I
k�
I�
C=1 1
k� I
CREEKSIDD
LOT #72
+I al
PROJECT*
04321.200 072R1�
,MODEL:
4EHI3 "I
"2605—HAYDEN"
AGE SWING. (.
RIGHT
Y
PAGE:
C„
r
FOUNDATION
PLAN a'
160 MPH EXP. C l'
ARCHITECT -
STATE OF FLORIDA
OCT 173019
MICHAEL C. ANDERSON
AR NO 17305
". zee$n'&�'�i'��5.,'zi`t'•`as.ttxiYA;;,;..
16� 14 19
DATE:
SCALE: 1 /4"=1' — N"
SCALE: 1/4" = 1'-0"
SHEET
s l
IT
"
n�
r-
I",
Z
I
STEEL REINFORCING IN GROUTED
,
CELL SEE PLAN FOR SIZE AN
SPACING REQUIREMENTS
,
O }
F-
�I
w
`
m
J
6;
00 I
v o_ 1
_
C-- coz
8" CMU WALL
„j
O CO
o
�x
co
TOP OF SLAB
uR
LE
4
SEE SLAB SCHEDU
EXT. PORCH SLAB L
4" CHAMFER (1-STORY)
W/ 1/2" ISOLATION 6" CHAMFER (2-STORY)
JOINT (WHERE • •
APPLICABLE) z SEE SCHEDULE
FOR WxD, BAR SIZE
AND BAR QUANTITY
c
BAR SIZE
48 BAR DIA.
#3
18"
#4
24"
#5
30'
#6
36"
#7
42"
1 EXTERIOR MONO -FOOTING
SCALE: 3/4"-1' 0"
2"CAPPED
GALVANIZED PIPE
Ix W/FLANGE @ BASE
0
cn
SECURE FLANGE TO
SLAB W/(4) 1/4°Xg.1,14"
TAPCONS'
BOLLARD.-.
SCALE: 3/4"=l'-0"
LAP TOP PLATE A MIN. OF48"
AND NAIL W/ 16d COMMON
NAILS, 2-ROWS, 4" O/C BTM.
LAP TO OCCUR OVER STUD
2x4 OR 2x6 WOOD BEARING —
WALL W/ SYP No 2 STUDS SEE
PLANS FOR SPACING. SINGLE
BTM. PLATE TO BE PT.
PROVIDE DBL. TOP PLATE
VERIFY HEIGHT
OF WALL W/ PLAN
PROVIDE BLOCKING
SECURE BT. PLATE TO
SLAB W/10d MASONRY NAIL
16" O/C STAGGERED.
ADDITIONAL METAL
CONNECTORS NOT
REQUIRED WHEN NO
UPLIFT IS PRESENT.
,SEE SLAB SCHEDULE
SEE SCHEDULE
FOR WxD, BAR SIZE
AND BAR QUANTITY
INTERIOR FOUNDATION WOOD WALL
SCALE: 3/4"=V-0"
(NO UPLIFT)
1
Z
STEEL REINFORCING IN GROUTED
CELL SEE PLAN FOR SIZE AND
EL
} SPACING REQUIREMENTS
¢ r
¢w (01
m C.)w
v IL
CC U
O 8" CMU WALL
CD
z
co 0101,
— +
TOP OF SLAB
VARIES J
SEE SLAB SCHEDULE TOP OF GARAGE 4
EXT. PORCH SLAB 4" CHAMFER (1-STORY)
W/ 1/2" ISOLATION 6" CHAMFER (2-STORY)
JOINT (WHERE SEE SCHEDULE
APPLICABLE) z_ FOR. WxD, BAR SIZE
AND BAR QUANTITY
EXTERIOR MONO -FOOTING
2 @ GARAGE SCALE:3/4"=V-0"
30"
MIN. EACH WAY
MONOLITHIC FOOTING
r
FM
p -- — CORNER BARS, SAME SIZE AS BAR
IN FOUNDATION WITH 30" LEG EACH
WAY AT ALL CHANGES IN DIRECTIONS
SO THAT THE STEEL REINF. IS CONTINUOUS
MATCH AMOUNT OF CONTINUOUS BARS
ilWHEN
LL
CONTINUOUS STEEL MONOLITHIC
FOOTING REINFORCEMENT SEE SCHEDULE
RANSITIONS ARE MADE FROM FOUNDATIONS HAVING
DIFFERENT NUMBER OF CONTINUOUS BARS PROVIDE THE LEAST
NUMBER OF BARS (ie. 2 TO 3, PROVIDE 2 BARS), LINO
MONOLITHIC FOUNDATION
3 CORNER BARS DETAIL
SCALE: 3/4"=l'-0"
LA
w
on
I
NEW REINF. BAR
O IL
SECURED W/2-PART
¢
a
EPDXY. MIN. EMBED
J Q
8", LINO
p
FOLLOW ALL MANF.
= pC
SPECIFICATIONS FOR
= m
I
USE AND
~ cc)
PREPARATION OF
Z
4"
4"
HOLE.
c
w
J
o
o
Oco
O
-4" CHAMFER (1 STORY)
6" CHAMFER (2-STORY)
ADDING BAR TO
MONOLITHIC FOUNDATION
SCALE: 3/4" 9 0"
POURED LINTEL CONT. (TYP.)
8" CMU FILLED CELL (TYP.)
2X WALL FRAMING
" DIA. USP 7250SD BO
LTS LTS 5" O
S
MINIMUM EMBEDMENT INTO
GROUTED CELL, 4" FROM ENDS AND
16- O.C. VERTICALLY MAX
INTERIOR FRAME BRG WALL TO
mw
Q J
J �
U
w w
w=
U U
U
RECESS AROUND GARAGE
DOOR OPENING
LAP TOP PLATE A MIN. OF 48"
AND NAIL W/ 16d COMMON
NAILS, 2-ROWS, 4" O/C BTM.
LAP TO OCCUR OVER STUD
2x4 OR 2x6 WOOD BEARING -
WALL W/ SYP No 2 STUDS SEE
PLANS FOR SPACING. SINGLE
BTM. PLATE TO BE PT.
PROVIDE DBL. TOP PLATE
SCALE: 3/4"=V-0"
VERIFY HEIGHT
OF WALL W/ PLAN
PROVIDE BLOCKING
SECURE BT. PLATE TO
SLAB W/10d MASONRY
NAIL 16" O/C STAGGERED.
ADDITIONAL METAL
CONNECTORS NOT
REQUIRED WHEN NO
RB FOR
SONRY
ITS SET
ELEV:
U UPLIFT IS PRESENT.
w
¢ SEE SLAB SCHEDULE
_
+- 0' 0"
TOP OF SLAB
EQ. EQ. SEE SCHEDULE
FOR WxD, BAR SIZE
AND BAR QUANTITY
(DNTIE�RIOR�CU RB FOUNDATION WOOD WALL
'-0" (NO UPLIFT)
z STEEL REINFORCING IN GROUTED
SPACING REQUIREMENTS
CELL SEE PLAN FOR SIZE AND
co
Q ~
w
w _ z 8„ CMU WALL
O m1.4 1 r�
co TOP OF SLAB TOP OF SLAB
SEE SLAB SCHEDULE z w a
EXIT. PORCH SLAB
4" CHAMFER (1-STORY)
W/ 1/2" ISOLATION
6" CHAMFER (2-STORY)
•
JOINT (WHERE
APPLICABLE) z
MATCH STEEL
g
REINFORCEMENT
6" PVC CHASE iv
THRU FOOTING r
PER SCHEDULE
c� 0
6" PVC CHASE THRU FOOTING
MATCH STEEL
SEE SCHEDULE REINFORCEMENT
FOR WxD, BAR SIZE �+ PER SCHEDULE
AND BAR QUANTITY PVC CHASE
THRU FOOTING
2 SCALE: 3/4„_1,-0„
BAR SIZE
48 BAR DIA.
#3
18"
#4
24"
#5
30"
#6
36"
#7
42"
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
CREEKSIDE
LOT #72
ej
ftOJECT#
04321.200 072R1
4EHB
"2605-HAYDEN"
GARAGE SWING:
RIGHT
A .WAGE:
DETAILS
60
STATE OF FLORIDA
OCT 17 2019
MICHAEL C. ANDERSON
AR NO 17305
r'NaT:
SHEET
S1.1A
t`j
M
FIRST FLOOR DOWEL PLAN
SCALE: 1/4" = V-0"
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA32!
PH: 321-802-3591
www. a b d es i g n gro u p. co r
1 pv
r�
U
�v QQ
w �
tY
i
yy
LL
F
f7;
u
�4w,
G
CREEKSIDE
LOT #72
3 PROJECT#
04321.200 072R1 fId
-ZAODEr.
4EHB
"2605— HAYDEN"
,EGARAGE S G:
9. RIGH`I9
PAGE:
FIRST
FLOOR!
DOWEL
PLAN
0 MPH EXP. C;'
r ARCHrrECT-.
LlSTATE OF FLORIDA
M
ACT 17 ZUT9
C AEL C. ANDERSON
AR NO 17305
190 14
DATE: 1/ /
SCALE: 1 /4"=1' - 0"
SHEET
s i
IN
— W
O
CO U
TIE VERTICAL REBAR
TO HORIZONTAL
REBAR W/ 10" HOOK
r--GROUTED BOND BEAM
IIJ
p CLEAN OUT REQUIRED
Q FOR INSPECTION
co
OL 0'-0" FIN. FLR.
TIE VERTICAL REBAR
TO HORIZONTAL
REBAR W/'10" HOOK
BAR SIZE
48 BAR DIA.
#3
181,
24"
#4
#5
30"
#6
36"
#7
42"
HORIZONTAL/VERTICAL
REINFORCING
SCALE: 3/4"=V-0"
w W
� V
>
NEW REINF. BAR
SECURED Wl2-PART
IL a
I
EPDXY. MIN. EMBED
6" UNO
-
FOLLOW ALL MANF.
S
m EsSPECIFICATIONS
I
FOR
_ Cc
USE AND
PREPARATION OF
m
z co
HOLE.
w
\ �' cooQIle
STEEL REINF. OF
BOND. BEAM
ADDING BAR TO
4 BOND BEAM
SCALE: 3/4"=V-0"
ME
Z_
N
OFFSET METHOD CONTINUOUS
METHOD
HORIZONTAL/VERTICAL
REINFORCING 2
SCALE: 3/4"=V-0"
BAR SIZE
48 BAR DIA.
#3
18"
#4
24"
#5
80"
#6
36"
#7
42"
#5 BARS
FEII
1• 8" 1,
i CMU UNIT DIMENSIONS
0 ARE NOMINAL SIZES
MASONRY SYMBOLS
3 SCALE: 3/4"=V-0"
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
F�
r,
1
a;
�
f
�
�p
ll Ifi
k11
I•
a,
C
k w
k
SM
u 1
I k
}
s� A
a
E (('
k
8
t'
ffx%FV:�,"Al-I
I�
Im
CREEKSIDE
LOT #72
PROJECT#
04321.200/072R1
n
MODEL:
4EHB
r ",11-'005-HAYDEN"
-AGE SWING:
I RIGHT
hl
PAGE:
Sd
FT Q
A'v
Y+N
l
1 0) IVI 1-1 EXP. C,
ARCHITECT:
STATE OF FLORIDA
nIT 1
MICHAEL C. ANDERSON
AR NO 17305
aINT 10 14 19
SATE:
SCALE:1/4"=1'-0"
SHEET
�a2A
FRAMING NOTES:
1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE
CONCRETE TO WOOD ROOF:
USP HTA16 W/ (9) 1 Od x 1 1/2" HDG NAILS.
CONCRETE TO WOOD FLOOR:
USP LPTA W/ (10) 1 Od x 1 1/2" HDG NAILS,
WOOD TO WOOD:
USP RT16A OR LUGT2 W/ 1Od x 1 1/2" HDG NAILS, FILL ALL HOLES.
2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER
SCHEDULE.
3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE
MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS
ARE TO MATCH CONNECTOR FINISH.
5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL
MANUFACTURER SHOWN IN STRUCTURAL PLANS.
6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND
CLEAR SPAN OPENINGS.
7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4").
8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE
SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE
FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS
LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND
APPROVAL.
9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES
SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED
FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C.
10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END
UNLESS OTHERWISE SHOWN DIFFERENT.
11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON
RATIONAL ANALYSIS.
12. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS
NOTED OTHERWISE.
HEADER SCHEDULE
MARK SIZE & REMARK
DESCRIPTION
1O (2) 2X8 --------
BEAM SCHEDULE
INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / B.O.L. = BOTTOM OF LINTEL / T.O.A. = TOP OF ARCH / T.O.S = TOP OF SLAB
ABBREVIATIONS
E.E. = EACH END, O/C = ON CENTER. F.E.S. = FROM EACH SUPPORT. T.O. = THROUGHOUT
REINFORCEMENT
STIRRUPS
MARK
DESCRIPTION
(psi)
WZE
REMARKS
BTM.
TOP
MID
SIZE
SPACING
BB1
MASONRY
3000
8x16
—
(1) #5
(1) #5
N/A
—
GROUTED SOLID
BB2
MASONRY
3000
8x8
—
(1) #5
—
N/A
—
GROUTED SOLID
"CAST-CRETE" SAFE LOAD TABLES
SAFE GRAVITY LOADS
FOR
8" PRECAST
& PRESTRESSED
U-LINTELS
1
SAFE LATERAL
8" PRECAST & PRESTRESSED
LOADS
FOR
U-LINTELS
1
SAFE UPLIFT LOADS
FOR 8"
PRECAST
&
PRESTRESSED
U-LINTELS
C
SAFE
LOAD
-POUNDS
PER
LINEAR
FOOT
*WF44~m
SAFE
TOAD
I►r lc~m
�'��,��11
SAFE
LOAD
-POUNDS
PER
LINEAR
FOOT
TYPE
LENGTH
8U8
8F8-0B
8F12-0B
8F16-DB
BF20-0B.
8F24-0B
SF28-0B
8F32-DB
TYPE
LENGTH
8U8
8F8
RCMU
TYPE
LENGTH
BFB-lT
BF12-1T
8F16-lT
BF20-IT
8F24-lT-
8F28-lT
8F32-lT
8F8.16
8F12-1B
8F16-18
8F20-1B
8F24-16
BF28-1B
BF32-1B
BF8-2T
BF12-2T
BF16-2T
BF20-2T
BF242T
8F28-2T
BF32.2T
T-6" (42") PRECAST
2231
3069
3719
5163
6607
8054
9502
10951
T-6" (42") PRECAST
1025
1024
1598
T-6" (42') PRECAST
1569
2856
3524
4394
5263
6132
7001
3o69
4605
6113
7547
8974
10394
llaos
lsss
zsss
3524
4394
5263
6132
7001
4'-0" (48') PRECAST
1966
2561
2751
3820
4890
5961
7034
8107
4'-0" (48") PRECAST
765
T63
1309
4'-0" (48") PRECAST
1363
2305
3060
3815
4570
5325
6079
2693
4605
6113
7647
8974
10394
11809
1363
2305
3080
3815
4570
5325
8079
4,-0" (54") PRECAST
1589
1969
2110
2931
3753
4576
54M
6224
4' -8" (54") PRECAST
592
591
1073
4'-6-(54"} PRECAST
1207
2040
2707
3375
4043
4711
5379
2189
4375
6113
7547 0
8672
10294
11809
1207
2040
2707
3375
4043
4717
5379
5' 4" (64") PRECAST
1217
1349
1438
1999
2660
3123
3686
4249
6-4- (64") PRECAST
411
411
745
5'-0" (64") PRECAST
1018
171�11)
2276(0
2838
3399
3961
4522
1663
30M
5365
7547(3q
7342os,
8733„•)
10127,,
1016
1715
2276
2838
3399
3961
4522
5'-10" (70") PRECAST
1062
1105
1173
1631
2090
2549
3009
3470
5'•10" (70') PRECAST
340
339
616
5'-10" (70") PRECAST
909
15670s)
208q,3)
2593
3107 (a)3620
p
4133 4)
1451
2622
4360
71eet„)
6036)„)
7181u„
8328w)
929
1567
2080
2593
3107
3620
4133
6'-6" (78") PRECAST
908
1238
2177
3480
3031
3707
4383
5061
6'-6" (78") PRECAST
507
721
490
6' 6" (78') PRECAST
83512
1407(2s)
18 2,
2329,
279q,$)
3251,
3712(z)
123E
2177
3480
5381
8360
10,3943n
8825(14)
835
1407
1868
2329
2790
3251
3712
�'-6" (90') PRECAST
743
1011
1729
2632
2205
2698
3191
3685
7'-6" (90") PRECAST
424
534
363
7'-6" (90') PRECAST
727 23
106 ,
162 1,
2025(20
2426(aa
2827a)
3228 ,
loll
1729
2661
3898
5681
84670q)
6472115)
727
1224
1624
2025
2426
2827
3228
9' 4" (112") PRECAST
554
899
1160
1625
2564
3486
2818
3302
9' 4" (112") PRECAST
326
512
230
9'-4- (112") PRECAST
591
708 m
11363a
1474
181 N
2157u
25003,
752
1245
1843
2584
3486
47D5(3n
6390pr)
597
882
1318
1843
1989
2294
2619
10' 6" (126') PRECAST
475
535
890
1247
2093
2777
2163
2538
10' 6" (126") PRECAST
284
401
180
10'-6" (126") PRECAST
530
575
918(33)
1188(33)
1461(33
1T36,,
2011,
843
1052
1533
2093
2781
3643ryq
4754 Ns)
530
695
1180 p)
1472 w
1763 (2
2055
2346
11'�" (136") PRECAST
362
582
945
1366
1846
2423
3127
4006
11'4" (136") PRECAST
260
452
154
11'-0" (136") PRECAST
474
504(m)
8D03z)
1037(32)
1274
151332
17533z
sm
995
1366
1846
2423
3127
4006
494
607
1042(10)
1372(11)
1643 p)
1915(o)
2187 (s)
12'-0" (144") PRECAST
337
5O
873
1254
1684
2193
2805
3552
12'-0" (144") PRECAST
244
402
137
12'-0" (144") PRECAST
470 y
458 (,)
724 F1)
938 ,3a)
1153raz
1369m
1585(,)
540
873
1254
1694
2193
2805
3552
470
550
940(,o)
130215
1560(13)
1818,1)
2075,0
13'4" (160") PRECAST
296
471
755
1075
1428
1838
2316
2883
13'�" (160') PRECAST
217
324
110
13'�" (160") PRECAST
418 (,$)
388=
ON M
785 ,aa
964 cao,
1143p,)
1323t,,,
471
755
1075
1428
1838
2316
2883
428
460
780 (9)
1159w)
1418,m,
1ss$,o)
1887pr,
14'-0" (168") PRECAST
-
279
424
706
1002
1326
1697
2127
2630
14'-0" (168") PRECAST
205
293
100
14'-0" (168") PRECAST
384(15
358(2,)
560(zs)
724m)
889go
1054(3o
1220w
442.
706
1002
1328
1697
2127
2630
41D
425
717 m
1063 1
1
1582
1807p,)
"
14'-8' (178) PRESTRESSED
N.R.
MR
MR
MR
MR
MR
NR
MR
141-80 (176") PRESTRESSED
N.R.
284
91
14'-8" (176") PRESTRESSED
239
334 pp
520 (n)
672 (29)
825 (20
978 Qo
1131(3o)
458
783
1370
1902
2245
2517
2712
395
663
990 w)
1
1518
1734
15'-4" (184".) PRESTRESSED
N.R.
MR
MR
MR
MR
MR
MR
MR
15'�" (184") PRESTRESSED
N.R.
259
83
15'�" (184") PRESTRESSED
224
313 z0
488 (za)
827 (za)
769 ¢s)
911 0
1054)zs)
412
710
1250
1733
205e
2320
2513
230
388
818
908 ro,
1240psj
1460r
1668za)
1T-4" (208") PRESTRESSED
N.R.
MR
MR
MR
MR
MR
MR -
MR
1T�" (208") PRESTRESSED
N.R.
194
64
1T 4" (208") PRESTRESSED
187
263 ,
405
521
638
756
873
300
548
950
1326
1609
1849
2047
192
305
506 a)
,
740 us
1 005(za)
12710,
1473 3t
19' 4" (232") PRESTRESSED
N.R.
MR
MR
MR
MR
MR
MR
MR
19'-4" (2321) PRESTRESSED
N.R.
148
52
19'-4" (232") PRESTRESSED
162
229 or.
348 m
447 m
547 m
647
747 (2s,
235
420
750
1037
1282
1515.
1716
166
263
429 (a
623. os)
841,,
1059(00,
1227(m,
21' 4" (256") PRESTRESSED
N.R.
MR
MR
MR
MR
MR
MR
MR.
21'.1" (256") PRESTRESSED
N.R.
125
42
21' 4' (256") PRESTRESSED
142
2D4 (,
307 )
393 (z3)
480 (33
568 )
655 )
180.
340
598
845
1114
7359
1488
142
232
373 p,
537 a7)
721 (a,
905
1049(a,
22'-0" (2640) PRESTRESSED
N.R.
MR
MR_
MR
MR
MR
MR
MR
22'-0" (264") PRESTRESSED
N.R.
116
40
22'-0" (264") PRESTRESSED
137
197 (is)
295 (az)
379 in)
462 (a,
546 (23)
630 (a,
165
315
550
784
1D47
1205
1399
137
223
388
513 pry
BBB
863
898
24'-0" (286") PRESTRESSED
N.R.
MR
MR
MR
MR
MR
NR.
MR
24'-0" (288") PRESTRESSED
N.R.
91
33
24'-0" (288") PRESTRESSED
124
179 (,a)
267 R,)
342 (2u
418 (zp
492 !
567 (22,
129
250
450
654
BB4
709z
t2z2
124
202
319 ml
455 (ioj
6Wpil
757 vi)l
878 a)
(#) THE NUMBERS IN PARENTHESIS
REDUCTIONS FOR GRADE
40 FIELD
ARE PERCENT
ADDED
REBAR.
(#) THE
REDUCTIONS
NUMBERS
IN
FOR GRADE
PARENTHESIS
40
ARE
FIELD ADDED
PERCENT
REBAR.
- ALL VALUES TAKEN FROM "SAFE LOAD TABLES" BY CASTCRETE MAY 2015 EDITION PRECAST PRODUCTS BY OTHERS TO MEET OR EXCEED VALUES STATED ABOVE
-ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS PROVIDE MINIMUM 4" OF BEARING PAST EACH SIDE OF WINDOW OPENING
PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION-CASTE-CRETE
DIVISION ACCEPTANCE #: 16-0126.03
1:
0.❖.•:.❖.❖:❖.❖:❖.❖.❖:•.
..
cli
##•i•
co
.;: ;:•
.. •
'1♦ :•
o•—
nt ;.;.
LL
.�•� ••'
..
8F40-1T/1 WOB
8F32-1 T/l M/OB
TOP OF WOOD WALL
EL 8'-8"
1
T/1
8F44-1 T./1 M/l B
.........❖.•.. • . • .�.�. • ..•••. • • .. ...� �.� . • ..!.!.!:
8F32-1 T/1 M/OB
1
UNO, PROVIDE BB1
WHERE TRUSSES BEAR
TOP OF WALL EL. 10'-8"
FIRST FLOOR LIFT BEAM PLAN
SCALE: 1/4" = V-0"
ti
Pq
03
64
4
03
A
F
6.:
ti
SVBDIV. 8e LOT:
CREEKSIDE
LOT #72
PROJECT*
04321.200 072R1
MODEL:
4EHB
"2605- HAYDEN"
c�ARwciE SWING:
RIGHT
PAGE:
FIRST FLOOR
ILIFT BEAM
PLAN AND
NOTES
'M MPH EV. C
ARCHrrECT-
STATE OF FLORIDA
OCT 1-) 2019
MCFML C. ANDOISON
AR NO 17WS
r""°' 10 14 19
DATE:
SCALE: 1/490=10
-0ts
SHEET
S2
Y
i
#5 CORNER BAR W/ 30"-LAP FOR EACH
COURSE OF BOND BEAM
VERTICAL REBAR W/ 10" HOOK
7
wl
30" TYPICAL
#5 BAR IN BOND BEAM
CORNER
REINFORCING OF BOND ,BEAM-
OPEN FACE SHELL SO
AS TO ALLOW BENT
BAR TO BE PLACED IN
UPPER AND LOWER
BOND BEAM
SI:ALt:
SINGLE BOND BEAM
AT HIGHER ELEVATION
SINGLE BOND BEAM
AT LOWER ELEVATION
#5 BAR BENT
ASSHOWN
#5 MIN. REQUIRED IN
EACH CELL HOOKED IN
TOP BOND BEAM W/
STANDARD ACI HOOK
CORNER BARS
3 AT CORNER STEP
SCALE: 314"=1'-0"
'-01,
NOTES TO THE INSPECTOR/CONTRACTOR TYP.8"X8
1. PLACE LINTEL ACROSS TOP OF OPENING. BOND BEAM Co 1#5
2. IF BOTTOM STEEL IS REQUIRED PLACE #5 BAR IN LINTEL.
3. PLACE MASONRY UNITS AS REQUIRED TO ACHIEVE THE REQUIRED BEARING $
\N PLACE STEEL HEIGHT.
OF REINFORCING (L2) 4. THE LAST COURSE WILL BE A BOND BEAM WITH (1) #5 BAR CONTINUOUS AROUND
AS DEPICTED HEREIN. STRUCTURE. A DOUBLE BOND BEAM MAY BE SPECIFIED SO THAT THEN THE LAST 1#5
TWO COURSES ARE BOND BEAMS WITH A #5 BAR IN EACH COURSE. TYP. 8 xl6"
O���P�V / COURSELOF BOND BD THE EAMLE BISOOMIITTED ANNDND BEAM NA LINTEL S PLACED. THE STEELCIDE WITH A LINTEL THE BOND BEAM
/ REINFORCING FOR THE BOTTOM BOND BEAM IS TO BE CONTINUOUS THROUGH THE 1#5
TOP OF THE LINTEL. 8" A\r\• 6. UNO COMPOSITE MASONRY BEAM IS TO BE NOT LESS THAN 16" DEEP.
8xl 6 DBL. BOND TOP O
BEAM W/ (1) 5 BAR BOND BEAM
EACH COURSE
G 8X8 BOND BEAM TOP OF
• OQ�r\\� W/ (1) #5 BAR Loy BOND BE;
!� F =FILLED W/ GROUT _
Y\� U =UNFILLED GROUT SOLID FROM TOP
NOMINAL LINTEL TO TOP OF BOND OF OPENING
WIDTH # OF #5 S, IN 2ND BOND BEAM
BEAM COURSE SITE 5
8x8NOMINAL ��LIN PRE -OAST CONCRETE
1 6- 1 T/ 1 /O B
LINTEL W/ (1) #5 BAR (L2) MASONRY
LENGTH OF BAR WIDTH OF
QP� HEIGHT #OF#5'S,TOP OPENING-2" BEAM DESIGNATICI
4' BOND BEAM COURSE OR —
IT IS THIS ENGINEER'S INTENT # OF #5'S, BOTTOM 8x8 PRE -CAST CONCRETE SCALE: 3/4"=1'-0"
THAT XFXX 1T/1 M/OB INDICATES A DOUBLE BOND BEAM
PLACED IN LINTEL LINTEL, W/O STEEL (L1) REFER
AND XFXX - 1T/OM/OB INDICATES A SINGLE BOND BEAM TO PLAN FOR LOCATIONS TOP
OF OPENING
WINDOW
31/4"
PRE -CAST
N
WINDOW I z r
SILL _
L SPE O
TYPICAL MASONRY WINDOW
SILL CONSTRUCTION
SINGLE #5 CORNER
BAR, 30x3O TURNED UP
OR TURNED DOWN INTO
FILLED CELL
STEEL REINF. OF
BOND. BEAM
JI:ALt: I I
STEEL REINF. OF
BOND. BEAM
PROVIDE #5 BAR
AT EACH SIDE
OF ELEVATION
-- CHANGE
CHANGE IN
ELEVATION OF BOND BEAM
SCALE: 314"=l'-0"
de
Sa
WOOD SECTION
FASTENER SPACING
de =2" MIN, 2 4`.' MAX
Sa=21MIN, 9"MAX
(2) 2x4
sr =1 #" MIN, 2 7" MAX
ed = of MIN', 2 J" MAX
de =2"MIN, 2 4" MAX
sa = 2 q MIN, 9" MAX
(2) 2x6
sr =1 J' MIN, 2 Z" MAX'
ed = 4" MIN, 2 z' MAX
de =2" MIN, 2 4" MAX
sa=2q. MIN, 9"MAX
(2) 2x8
s, =1 2' MIN, 2 2" MAX*
ed=J'MIN, 2�'MAX
NOTE`,
• ADJACENT NAILS ARE DRIVEN FROM
OPPOSITE SIDES OF THE COLUMN
• ALL NAILS PENETRATE ALL
LAMINATIONS AND AT LEAST 1 4" OF
THE THICKNESS OF THE OUTERMOST
LAMINATION
WHERE:
da = END DISTANCE
sa = SPACING BETWEEN ADJACENT FASTENERS
1N A ROW
s, = SPACING BETWEEN ROWS OF FASTENERS
ed = EDGE DISTANCE
*MUST HAVE 2 OR MORE LONGITUDINAL
'ROWS OFNAILS
DOUBLE STUD W/ 10d NAIL ATTACHMENT
SCALE: N.T g_
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
c
AA, #: 0003325
i
a,
rr
$I
k1
�a
W �a
r
t
a�
u i
ezz.
S CT]BDIV. 8e LOT: `,A
h
CREEKSIDE 3
LOT #72
PROJECT#
04321.200 072R1
MODEL.
4EHB
"2605—HAYDEN"
GARAGE SWING:
RIGHT
a+
a..r
k-GE:
DETAILS
160 MPH E-A, I
ARCiirrEc T:
QTATE OF FLORIDA
// - ��
/ '
C1 OCT 1 7 2019
MICHAEL C. ANDERSON
AR NO 17305
r-��)�TT 10/14/19
SHEET
A S 11 7
-
I�
FRAMING NOTES:
C
1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE
CONCRETE TO WOOD ROOF:
USP HTA16 W1(9) 10d,x 1 1/2" HOG NAILS.
CONCRETE TO WOOD FLOOR;
USP LPTA W/ (10) 10d x 1 1/2" HDG NAILS,
WOOD TQ WOOD:
USP RTI6A OR LUGT2 W/ 10d x 1 1/2" HDG NAILS, FILL ALL HOLES.
2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER
SCHEDULE
3 ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE
MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH
MANFACTURER'S SPECIFICATIONS.
w
4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS
ARE TO MATCH CONNECTOR FINISH.
e
5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL
MANUFACTURER SHOWN IN STRUCTURAL PLANS.
6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND
CLEAR SPAN OPENINGS.
7. LINTELS SHALL HAVE 4 NOMINAL BEARING (4").
8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE
SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE
FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS
LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND
APPROVAL.
9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES
SECURE2x MEMBERS TO WALL WITH HILTI X ZF, POWDER ACCTUATED
FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG WITH WASHER @ 16' O.C.
10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END
UNLESS OTHERWISE SHOWN DIFFERENT.
11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON
RATIONAL ANALYSIS.
12. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS
NOTED OTHERWISE.
TRUSS MANUFACTURER / ENGINEER NOTES:
1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500LBS SHALL BE
FABRICATED W/ A 2x6 BTM. CHORD (MIN.)
2- COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS
WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT
SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES.
3. TRUSS COMPANY /.ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO
TRUSS CONNECTIONS.
4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN.
MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN
COLUMN SCHEDULE
SIZE & BASE PLATE OR
MARK DESCRIPTION REINFORCEMENT REMARK
WD 1 4X6 (3Y2N5/2") SYP. USP HTT4 W/5/8" DIA 5/S3.1A
PT., WOOD POST x 5" EXP. BOLT
FIRE
DRAFT STOP
FLOOR-
- 2X4 NAILER
FOR DRAFT
PRE-ENG. STOP
FLR. TRUSS
ELEV. VIEW i
PRE-ENG. FLR. JOISTS �I
�I
3/4" PLYWOOD���( )
DRAFT STOP
PRE ENG. FLR JOISTS
2X4 NAILER FOR
DRAFT STOP
3/4" PLYWOOD
DRAFT STOP
PLAN VIEW
DRAFT STOP
DETAILS
CONNEC1OR SCHEDULL
II CONI ROL DAI L:01-15-1]
Mll ek USP
SIMPSON
Mil ek USP
SIMPSON
DL5
UPLIFT
GRAVITY
DLS,
UPLIFT
GRAVITY
FAST WLR
FASI LNL
I ITA 16-1H
1625
MEFA-16
1450
- Y ] lfid 2-PLY, E E04
(8) SOd X 11/2 1 PL , (1 MB
B 1Dd 1121-PLY
( /
61d2P t 8t04
6 E,
O ,T ,
(2)H1A 16-18.
(2)
24M
(2)MElA16
1985
(12f lOtlxl 1/2
(10) Lod 11/2}-PLY,#Mp`
"S
1900
(10)14d 2-PLY, LMBLD4"
114)16d2PLVL
SED4
I HA 16
1870
1IL1 A-16
1830
(10)lad X 1112 (9)16d 2-PLY, EMBED4
(9)10d x 11/2"I-PLY, 18)16d 2-PLY, EMBED4'
I ITA 20
1870
1ILIA-20
1810
(10)10d x 11/2 , (8) I6d2-PLY, EMBE04
(9)10d x
11/2" 1-PLY, 18)16d2 PLY, EMBED4'
i
I2111TA-20
2430
I2111ETA-20
2035
:
(12)1Dd x 11/2", I -PLY, EMBED4
(10) l0d
x 11/2"" I -PLY, EMBED 4
2500
(10)16d 2-PLv, LA�BtU4"
112116tl2
PLY, EMBED 4
z
0LOGI-2
L'160
LGl-Z
2150
BLK 511/9"x 3'Wedge-BaIN An[hOry WOWH6)10d
(])-1/4'x2.1/4"iI1LN,
WOW 1616d
DI 11 A-20
2410
UL1AL-.20
248U
(l6)- Had xll/2,SPLYALT[RNATE USE OFI2111TA 20ACCCPTABLC.
(18) 1 O
x11/2, 1 PLY ALTERNATE USE OF (2) I IOTA-20 ACCEPTABUL
g
MUG115+
4175
MGT+
3965
EIS/8'A.T.R. IN HIGH STRENGTHCPDXY(MIN.12 EMBCD),(22) 10d TOWOOD)
(1)5/8
TR:INIIIGII STRCNGTII EPDXY (MIN. 12" EMBED),(22) 10d TO WOOD
IIUGT2+
9790
II6T-2+
10980
WOOD (8) 10d, MASONRY (2) 3/4 AIR
(2)9/4
1R IN HIGH SIRENGiH EPDXY (MIN. 121,MBED),(15)10dl0W000
IUGT3+
9860
IIGT-3+
10530
WOOD (8) 10d, MASONRY (2) 3/4 AIR
(2)3/4
1H I N HIGH 51 RENGI H E FOXY (MIN. I2EMBEDI(16) 10d 10 WOOD
I
LUGid
3525
LG13-SOS2.5
3295
CORE (4)3/8"X5"Wedgo-Bolt+ Anchors, WOOD (12) WS25
(12)SUS
/4x3 10 GIRDER,(4)3/8"xS" 111 LN I ID IO WALL
LPTA
1510 PARALLLL IO WALL
P6NPENUICUTARIO WALL.
LTA2
1210 PARALLLL IU WALL
1210 PERPENDICULARTO
WALL
(10110d x 11/2'
(10)106
,
11/2
MUG115
415O
VGT
4940
(1)5/8"A.T.R. INNIGHSTRENGTH EPDXY(MIN.1VEMBED),(4)IMTOP/(6)1dFACE/(12)lOd BAOCOFTRUSS
H.15/8
T.R. IN IIIGII STRENGTII EPDXY IMIN. 12' EMULDI,(16) SD51/4"x3"
I ILET
7185
(2) Val
7185
(2) 5/8" A.I.R. IN HIGH 51 RENGI H EPDXY (MIN. IVEMBED),(8) lad
(2)5/8
,1.R, I N HIG H SI R LNGI H L FOXY f MIN. 12 IMBED), (32)SM 1/41'x3"
MTW 12
1195
MTS-12
LOBO
(14)lOd x 11/2',(14)30d
(14)10d
1.1/2"
H1W16 -
12W
HIS-16
1150
(16) 10d X 11/,,(16110d
(16110d
11/2
111W 20
15M
I11 S-20
1450
(24)10d X 11/2;('20)10d
(24) Bad
11/2
111W 24
1530
1115-24
1450
(24) 10d X 11/2,(20) 10d
(24)10d
x 11/2
LSTA 12++
930
LSTA-12 ++
925
(10) Bad -
(10)lOtl
LSTA 18++
1235
LSTA-19 HE
1235
(14)10d
(14)10tl
MSIA18++
1310
MS1 A-18++
1315
(14)10d
(14)lod
MS1A-24,
1640
MS1A,24«
1640
(18)10d
(is)lod
MS1A 30++.
2UG5
MSI A-M++
2050
(22)lod
(22)lad
MSTA36.
2065
MSTA-36++
2050
(26)lad
(26)30d
N
KSTI236
3890
MSTI-36
3800
(26)10dx 11/2
(36)10tl
11/2
KTS1248
5140
`
M51148
M65
(49)10d X11/2"
(49)10d(11/2"-
LHAb
1210
116
950
(16) 8d x 11/2',(16) 8d)
BISBE
PLATE$Da8d TOSTUDS
SP124
1030
SP4
885
(b)10c IOS1UDS(6)1M10PUMIF -
(6)10d
11/2 TSTUDS
MP34
5251N F1 @16D'%
A34
513IN F1@
180W.
(9)8tlx31/2"10 BEAM, (4)Bdxll/2"10 P051.
(4)8dx
1/2 10 BtAM,(48dx11/2"lO POST.
HHCP2
SEE
HCP2
645
(10)Wdxll/2-IOIRUSS,(10)10dX11/2"1OPLAIL
(12)10tl(1112"
R116A
1380
IUDA
1140
(9)10tl x11/2 TO TRUSS (8)10d Xt 1/2 TO PIATC
1810d
( )
112
(
MUGl15&PIIL]0.4
4175
VGl&IIDU4
4565
(28)1(10101R S,Il IS'WOOD .-N:10'QM W/5/%1H R1ADtD NOD
(16)SUS1/4x3lOW()tIDH(+SOS
1/9x2112" W1 I HREADLD ROD, (2)NUTS/WASHER/2 PLY '
MUGT15&PIICWA
4D5
VGT&IID]B
4940
(28)1Od101 RUSS,(10)WS3 WOOD SCREWSTO POST W/5/8"IHREADWROU
(16)SUS
1/4x3"10 WUW(31-3/4":SI DO BOLTS.W/IHRLADLDROD,(2) NU15/WASHER/2PLY
PAU44
2535
6A5
ABU 44Z
2200'
6665
(1) 5/8" A.I.R. IN IIGI I SI RLN6111 EPDXY, (MIN.]" EMBED) IN COW, (12) 16d1UWOOD
(1)S/8"
1.R. IN I IIGI 151 RLNGIII LPDXV,(MIN:]'LMBLD) IN:CONG, 11211bd10 WOOD .
PAU66
2390
16005
ABU 662
2300
12000
(1) 5/8' A.I.R. IN IIGI I SI NENGI II EPDXY, (MIN.]' LMBLDIIN CONC.,(12)lbd10WOOD
(1)5/H'
1.R. IN 11161151 RLNGII I EPDXY, (MIN, J"LMBLD) INCONE.(12)16d TO WOOD
LTS19 +++
1205
L1119++C
1340
(1)3/4" A.I:R. IN I Hal 15) RLNG111 EPDXY, (MIN.]" LMBLD) IN COW,(8)1M IU WOOD
(113/4
I.N. IN II IGI I SI RLNG111 EPDXY, (MIN. ]"LMBLD) INCON6.,(8)10d10WOOD
LI S20B+++
1100
-1120B+++
ICED
(113/4' A.T. R. I N I I IGI I STR ENGTI I EPDXY, (MIN.] EMBED) IN COW.,(1011M x 1-1/2 TO WOOD
(1)1/2
T.R. IN HIGH STRCNGTII EPDXY, (MIN .}" EMBED) INCONC., 1101 10dTO WOOD
�
2
11745
4160
IITT4
4235
(1)5/8" A.I.R. IN HIGH SI SENGI H EPDXY (MIN.]" EMBED) IN GERI(18) 16d X 21/Z"
(115/8
1N IN HIGH S1RtNG1HEPDXVIMIN.]"EMBEU,IINCONC., (2611fitl%Pl/2"
ZZ
11745
5005
IITTS
509C
(1)5/H"A.I.R, N HIGH S1RIFNGTH EPDXY (MIN.]" EMBED) IN CONI(26) 16tl X21/P'
(1)5/%
1.R. IN HIGH S1 RkNG1 H EPDXY IMIN. 7" EMBED,) IN CORE, (26)166 X 21/2".
Q
u PHU11+
14395
HHD011-SUS
1�.
11830
(1) 1' ALR. INIIIGH STRCNGTII CPO%Y,.MIN.ID"EMBED IN CONE., (29)W53 WOW SCREWS -(11
A
R IN IIIGII STRCNGTII CPO%Y,1MIN 10 " EMBED) IN COW., (24) SIDS Y, x2X"WOODSCREWS
PI ID5A
6525
1107B
6645
(1)5/8 A,6- IN HIGH SIRLNGIH EPDXY, (MIN ]" LMBLD)INCONC H4)WMWWOSCREWS
(1)]/8
B IN HIGH Si RENGiH EPDXY (MIN ]"LMBEU)INCUNC„13)3/4 S1UDBOL1STOW00D
TDXS
]8]0
(1)7/8"A.8. IN H IG H X IIIENG1 H L PDXV,(MIN,]"LMBEU)IN CONC.(3)]/W SI UD BOLL S 10 WOOD
NFM35Xi2U
2580
]130.
MBI IA
3.56/1125
3475
5330
(1)1/2"'1-8ULI W MIN b"EMBED &NO] LLSS I I IAN4 FROM EDGE OF CONCW/1/4"IAA IIW RAMSLI/RLDI ILAD
UYNA BULI SLEEVE ANCHOR 08k0 W/MINS"LMBEU INSIALLEUINFAC6(14)IDtlAIUUISI
(1)3/4
EPO%V,I
IR, IN 111611 S1 RLNGT I I EPDXY,(MIN 6d5"LMBLDMLNH IN CM:U.IOE,(1)3/4" AA.R IN I IIGI I SI RLNGI II
8t0MEN INCMUTAC 18'lUdlO BEAM
IN 6.75"kM 1) E,( 1 M
I IUS4121F
3060'
2710(100%)
HUSCAI2
(WOOD)
3635
2660(100%)
(10) 16d 10 HEADER, (10) 16d 10 WOOD
(10) I Ed
10 HEADER, (10) 16d 10 WOOD
33xs H2s%1
3265 (125%)
¢
w
LD
I4D9101F IEMDI
1950
5000
IIUC410
(fMU6
1H00
45U0
(19)1/4' x3"' WS3 SCREWS, (10) 10d TO
_
WOOD. USP (20) 3/16 IAPELR+, (10110d 10 WOOD
(18)1/4
23/4 11111N(9 PER kLANGL)lOCMO, (10)lOd IU WUOUt
Z
S
IID21UQ1F(OMU)
1950
5000
IIUC2102
LEND)
Iwo
4500
(18)1/4""z.3"' WS3 SCRLWS,(10µ0d10
WOOD USN (20)3/16""TAPPER+,{1U11UtlTU WOOD :
(18)1l4
x23/41. 111 LN 19 PER FEANGLI IO CMU,(101 iDd1U WOOD:
IIp21D-31F (COOT
1950
5000
IEMU)Q3
1800
4500
WUUDaUSP (20�/i6R9APPER+'11010d 3U WOW
(18)1/4
2 i/4 1 II EN(9 VER HANGE)IU CMU, (lU)lOd IU WOOD'.
LGUMLG-2
2125
6U65
LGUM26-L SUS
1430
5595.
(4)3/8"%4"Wedge BolN Anchors, WUOU(4)WSS WOOD SCNLWS "
(43/H x4111
LN IIDANCIIOHS(2 PER ttANGL)tU CMU, 411/4X2-1/1 SIri XRLW5l0 WOW
Ski
BM1 TO CMU WALL W/USP -
LGUM46 WI(4r/e x4" WEDGE
BOLTS AND (4) WS3 WOOD
SCREWS TO BM1, BLOCK W/
1/2" PL%WOOD EA. SIDE OF BM1
Los® a EJ3u aICJ1EN
,
'r3
L2G GT 1 A
i�
C.
9A 10B 3
II II II II 11 11 II II II II II II II II II II II II II II II .
II II II II II II II II II II II II II II II LI II I, II
II II II II II II II II (I 11 II II II II II II II II II II
II (( II II II II II II II 11 II II II II II II II II II II
IIIii ii ii ii J3IL IIJ2 Lo 11 II J9 II II II II
III II II it II II 11 II II II II II II If II
NI---IE II II II II II II II II II 2xWALL W/ II II II II II II
u n n 11 11 n
III (( II II II II ii ii li SYPN0.2 II II II II II II II II
II I II II II 11 2x4 WOOD WW/ STUDS @
ALL 12" O.C. aD
SYP. NO.2
w II II u u u STUDS@ I u n WDI u n I u
12" O.C.
BM1 2X6WOOii II II II
WALL W/ DBL.
4 STUD UNDER
_-_ J4 ===-41 EACH JOIST
J6 II
3.1 II i, II II Il II. II
to�� II II I ,II II IF ��
3 10B 9A III - - -
S3,1 3.1 3.1
-___--
11= 4
3.1
10B 9A
3.1 3.t
PRE-FABRIt TED FL
OOR I
JOISTS @ 24" O.C.
III o,
3 10B 9B II ;
-
3.1 3.1 3.1 --- - -�'_
- - - - - _ -
1A
T
3.1 CJ5E=
11 II II II II II III
�'e I I II II II II
1 I CJ3E
II 11 II II II II II
11-1 11 11 EJ6E
CAE u
11 IF II L_11 11 -It j II
- H 11 11
EGE
Lu M
U U U
FIRST FLO
SCALE:'1/4" = V-0"
II LI / 'DBLSTUD� II II II II
II II n n II I I 3.1 1 11 (I
II II WOOD
WALL W DBL.
PROVIDE DRAFTSTOPPING
n n STUD UNDER II ALONG THIS TRUSS AS TO II
I� II EACH JOIST II PER 012 00 S.F.
ERFBCR 30I)
n n II n n L Ir
II _ II II II II J7 II II II II
L-1--LLL1 �4L -A-11
rLL
9A 10B 3
3.1
OR FRAMING PLAN
I -JOIST
rd
551 S. APOLLO BLVD.,
SUITE 202
nl MELBOURNE,
I
A,
FLORIDA 3290
PH: 321-802-3591
www.abdesitgngrm
h
sW
04
U
W
Ir1
0
r
v
4
f�
E-
(�'.. Q
E I'
Y^
t
CREEKSIDE
LOT #72
I,
,-"ROJECT#
04321.200/072R1 s
2AODEL:
4EHI3
�s
"2605-HAYDEN"
GARAGE SWINGE:
RIGHT
I PAGE:
FIRST FLOOR
FRAMING
PLAN
5dRXXD
ARC�I�I ECT
STATE OF FLORIDA
1
v -
OCTT T `2Q19
p `4 c'N'-VIES C. ANDERSON
R N0 T7305
.A, 7kEe 10/14/19
i. _.
SCALE: 1 /4"=11- 0'1
SHEET
S 3
ENGINEERED WOOD TRUSSE PLYWOOD SHEATHING, SEE
@ 24" O/C, SUBMIT SHOP ' ROOF/WALUFLOOR
DRAWINGS FOR REVIEW SHEATHING
AND APPROVAL FASTENER SCHEDULE"
PLYWOOD SHEATHING, SEE 2) USP HTA16 TRUSS ANCHOR
"ROOF/WALUFLOOR NITH (9) 1 Od x, 1 1/2" NAILS TO
SHEATHING TRUSS EA. PROVIDE 4" MINIMUM NOTE: FOR (A) W/ SINGLE
FASTENER SCHEDULE" DONCRETE EMBEDMENT. DEL PLY, A PT SYP #2 2"X6"X4'-O"
A-(1)USP HTA16 TRUSS ANCHOR WITH (9) TRAP, 1 EACH SIDE WRAPS UP MAY BE ADDED W/ 1Od
1Dd x 1 P H TO TRUSS. ANCHOR
AND OVER TRUSS (NOT NAILS, 2 ROWS, 3 O/C TO
B-(2) USP HTA16 TRUSS ANCHOR WITH (9) SHOWN) FACILITATE 2-PLY
10d x 1 1/2" TO TRUSS EA STRAP. FL#17680 SED IN UPLICONFT
EC WITH CONNECTOR. '
DBL STRAP, 1' EACH SIDE WRAPS UP AND EAVY UPLIFTCONNECTOR
OVER TRUSS (NOT SHOWN) L#1768Q
(A) USP LUGT2 W/ (5) 1/4"x3" POWERS
1x2, 2x WOOD FASCIA WEDGE BOLT& (16) 16 GALV. NAILS TO
SEE ARCHITECTURAL TRUSS (2PLY) #FL17240 (NOT SHOWN)
2x. SECURED W/ (3).16d (B) USP RFUS STEEL CONNECTOR WITH (4)
GALV. COMMON NAILS ENGINEERED WOOD 3/4"x6" WEDGE BOLTS AND
1x2 SECURED W/ 10d TRUSSES C@ 24" O/C, 1x2, 2X WOOD FASCIA (12) WS3 SCREWS FL#6223
GALV.. COMMON NAILS SUBMIT SHOP DRAWINGS SEE ARCHITECTURAL .
12" O/C FOR REVIEW 2x SECURED W/(3) 16dZ/z
AND APPROVAL GALV. COMMON NAILS. IF 4 BOLTS ARE USED
lx2 SECURED W/ 10d MASONRY BOND ENSURE THAT CELLS ARE GROUTED
GALV. COMMON NAILS BEAM SOLID, 8" EACH WAY OF BOLTS
MASONRY BOND BEAM 12 O/C A ALLOWABLE
SCHEDULE
SEE SCHEDULE UPLIFT = U:3980 LBS, L:1785 LBS (2PLY)
A ALLOWABLE UPLIFT = U:1870 LBS, L:710LBS (1 STRAP) B ALLOWABLE UPLIFT U:9000 LBS, L:1310 LBS (4 WEDGE BOLTS IN RFUS)
B ALLOWABLE. UPLIFT = U:2430 LBS, L:1310LBS (2 STRAPS)
TYPICAL TRUSS/ „ , „ _
1 A 1 B SCALE' 3/a =1 -o TYPICAL ROOF
GIRDER CONNECTOR(S) 2A 2B sCALE:3/4"=1-a'
GIRDER CONNECTOR(S)
3/4" T & G SUBFLOOR GLUED AND
SCREWED AS PER SCHEDULE
LSTA12 20 GAUG
W/ l Odxl/2 HPG OMMON NAILS.
@ EACH END TONAL OF 10
SERIES
BACKER BLOCK
THICKNESS
4500.
3/4" WOOD PANELS
6Q00
(2) 1/2" WOOD PANELS
60
(2) 1/2" WOOD PANELS
90
2x LUMBER
SERIES
BACKER BLOCK
THICKNESS
4500
3/4" WOOD PANELS
6000
(2) 1/2" WOOD PANELS
60
(2) 1/2" WOOD PANELS
90
2x LUMBER
LVUI-JOIST WITH -
BACKER BLOCK
PRE,
-ENG I -JOIST
5/8" GYPSUM BOARD OR 1/2" HIGH
STRENGTH CLG. BOARD
SECURE I -JOIST TO TOP PLATE
w/ (2) 12d TOENAILS
DOUBLE TOP PLATE
�— 2x4 OR 2x6 WOOD BEARING
WALL W/ SYP No 2 STUDS SEE
PLANS FOR SPACING. SINGLE
BTM. PLATE TO BE PT.
PROVIDE DBL. TOP PLATE
PROVIDE BLOCKING
1/2" GYP. WL. BD.
J <)
��LE: I -JOIST CONNECTION @ L.B.W.
3/4"=V-0' (NO UPLIFT)
NOTCH DEPTH 1/4*D
O
HOLE EDGE>5/8"
T HOLE DIAMETER
< 2'5*D SGL. STUD
OUTER 1/3OF
SPAN ONLY
—HOLE EDGE>5/8"
N__�
BTM. HOLE DIAMETER
PLATE <3/5*D DBL STUD
STUD NOTCHING
AND BORING LIMITS
8 SCALE: 1 1 J2"=1'-0"
HTT16 W/ 5/8" A.B. WITH
MIN. 7" EMBEDMENT
TO SLAB & (20) 16d x
2-1/2" NAILS TO POST-,
POST TO SIT DIRECTLY
ON SLAB
LVL/WOOD POST CONNECTIONS
A - USP TFL1716 G < 1230 LBS, U < 140 LBS W/ (2) 3/4"° WEDGE-BOLT/J-BOLT, 5" MIN.
EMBED (6) 1Od GALV. COMMON NAILS TO HEADER AND (2) 1Odxl-1/2" GALV. COMMON
NAILS. TO JOIST FL#17241
B - USP TFL2316 G < 1230 LBS, U < 140 LBS W/ (2) 3/4"° WEDGE BOLT/J BOLT, 5" MIN.
EMBED (6) 10d GALV. COMMON NAILS TO HEADER AND (2) 10dxl-1/2" GALV. COMMON
NAILS. TO JOIST FL#17241
BB - USP THF23160 GI < 1335 LBS, U < 140 LBS W/ (2) 3/4"° WEDGE-BOLT/J BOLT, 5 MIN.
EMBED (22) 10d GALV; COMMON NAILS TO HEADER AND (2) 1 Odxl-1/2" GALV. COMMON
NAILS. TO JOIST FL##241
C - USP TH035160 G � 2280 LBS, U < 265 LBS W/ (4) 3/4"°WEDGE-BOLT/J-BOLT, 5" MIN.
EMBED (12) 10d GALV I: COMMON NAILS TO HEADER AND (2) 1 Odxl-1/2" GALV: COMMON
NAILS. TO JOIST FL#17241
D - USP HBPH7116 G < 4140 LBS, U < 1610 LBS W/ (8) 3/4"° WEDGE-BOLT/J-BOLT, 5" MIN.
EMBED (16) 10d GALV!,. COMMON NAILS TO HEADER AND (10)'16d GALV: COMMON NAILS.
TO JOIST FL#25749 WOOD LEDGER
ATTACHMENT DETAIL
9 SCALE: 3/4"=1'-0"
# 1175 UPLIFT USP
HTWM20 W/10 1 Od TO
TRUSS AND (4) 1/4"x21/4"
TAPCONS TO CONT
POURED LINTEL
# 1900 UPLIFT (2) USP
HTWM20 INSTALLED ON
OPPOSITE FACES OF
BLOCK WALL W110 10d TO
TRUSS AND (4) 1/4"x 21/4"
TAPCONS TO CONT
POURED LINTEL
PRE-ENG TRUSS
CONTINUOUS BOND BEAM
-- TAP CONS MIN. 2"
COVER 2"APART
REPAIR OF MULTIPLE
MISPLACED EMBEDDED TRUSS ANCHOR
6'-0" MAX (W/1 X4)
OR 10'-0" MAX (W/2X4)
n n Jl_
lx4 DIAGONAL
BTM. CHORD
BRACING, SEE
PLAN FOR LOCATION
o U a MAY NOT BE
N ¢ a >- REQUIRED
F7
BTM. CHORD OF
I `T WOOD ROOF TRUSSES
lx4 BTM. CHORD BRACING 6'-O" O/C END WALL OR OTHER
MAX.; OR 2x4 BTM: CHORD BRACING END TYPE CONDITION, IF
10'-0" O/C MAXSECURED W/ (2) 10d DEPICTED SEE PLAN
COMMON NAILS AT EACH CHORD
INTERSECTION TYP. BTM. CHORD BRACING
6 SCALE 3/4"=l'-O"
SUALL: 314"=l'-U"
(2) 2X4 No.2 SYP DIAG. —
BRACE W/ (3) 12d @ EA.
TRUSS (DIAG. BRACE TO
COVER5TRUSSES)
0'-0" TO 30'- , 1) "X" BRACE
30'-1" TO 80'-0\FASCIA,
(1) "X" BRACE @
(2) "X" BRACE D
FROM CENTER
2x WOSEE APRE-ENG GABLE STIFFBACK (A
TRUSS ENG)
SEE SCHEDULE FOR 7"'
BOND BEAM REQ. .",
b
F
2x4 BLOCKING BETWEEN
/BOLT
WHERE
G IS PRE TAT
. (AT SH HING
2 PT. PLATE
1/2" DIA.
BOLT W/ 2"SET IN HIGHH EPDXY 6"ED. AT 32" OC
MAX.
SECURE GABLE TO 2x8
P.T. PLATE W/ 12d's 8"
O.C. MAX
CONT. 2x4 SECURED W/
(2) 1 Od's @ EACH TRUSS
TO BE INSTALLED @
10'-0" O.C. MAX.
_� BLOCK WALL W/ GABLE E�
7 J PRE-ENG'D TRUSS '
Eiji
24"
24" MAX. w,' I -JOIST
8" END
SPACING
8" MAX
END (W/I-JOI�T
TRUSS BR OR BTM
TYP.
TYP.
vP.
PACIN
SEE FRAMING FRAM NG PLAN
LED E
..LEDGER BD.
MAX.
MAX
.MAX
FROM
THE USE OF ALTERNATE MATERIALS MAY BE
LE2X8 SYP P.T.
DGER BOARD
C3
LU EDGE LEDGER BOARD TO
3/4"EXP.
.BOLT/J-BOLT W/ 2"
USED SO LONG AS THEY CONFORM TO THE
BOLT
BOLT'J BOLT51 2" TO BE USED
WASHER WITH I -JOIST.
BE USED WITH I -JOIST
1.ENSURETHAT RE
WASHER & 5112"
MIN EMBED. (TYP)
OI I O\A ING
FOLLOWING
.51/2
MIN EMBED. (TYP)
BOLTS/J BOLTS ARE PLACED
r L L V V
lr-I
INTO GROUTED CELLS, 8" ALL
AROUND BOLT. FRONT
2. SPLICE OF FRONT AND REAR LEDGER
'
1. METAL STRAPS FOR. ROOF AND FLOOR CONNECTIONS
LEDGER SHOULD LAP A MIN OF
A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS
Z
00
4' s":?
-
EQUIVALENT OR GREATER UPLIFT AND LATERAL (F1 AND F2) LOAD CAPACITIES
�
3. ALL BOLTS TO HAVE WASHERS 2 2X12
I�
AS THE ONE SPECIFIED., CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND
4, EXP.`BOLTS/J-BOLTS SHOULD svP PT
NOT BE ANY CLOSER THAN s"
ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE
O/C.
z_
THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO
co
ONLY LEDGER IN DIRECT
�
A USP RT16A (FL#17236) OR LUGT2 (FL#17240). ROOF TRUSSES ARE SUBJECT TO UPLIFT, Fl,
2) 2X8
CONTACT .REAR LEDGER) WITH REAR
(
_
H
AND F2 FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE
SYP PT
CMU REQUIRED TO BE P.T. LEDGER
SUBJECT TO Fl AND F2 FORCES.
FLOOR JOIST LEDGER SCHEDULE
MARK
A
SIZE
DOUBLE SYP 2x8
BOLT SIZE
1/2"
ENDSPACING
8" MAX.
CENTRALSPACING
24" O/C MAX.
B
DOUBLE SYP 2x12
(2) 3/4"
8" MAX.
24" O/C MAX.
1-JOIST WOOD LEDGER DETAIL
ALTERNATE MATERIALS
SCALE: 3/4"=l'-O"
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
� I
CREEKSIDE
LOT #72
PROJEC'']P
04321.200 072R1
'MODEL:
4EHB
"2605-HAYDEN"
GARAGE S VnNG:
RIGHT
PAC3'E: ')
I;
DETAILS
(I -JOIST)
EXF
ALM
I
ARCI-iITEC T:
STATE OF FLORIDA
OCT 17 2U19 _ f ^
MICHAEL C. ANDERSON
AR NO 17305
-ItINT 14 10 19
DATE: / /
SCAT :1/4"=1'-0"
SEiEET . 1
SGALE: 3/4"=l'-0
■
USP LFTA6 W/,
(16) 8d COMMON NAILS 2x STUDS #8 WOOD SCREWS x 2"
USP LFTA6 W/ (16) 8d EACH END LONG @ 3" O.C.;
COMMON NAILS, EACH FL#17244 STAGGERED
END EVERY STUD OR ON #8 WOOD SCREWS NI AS SHOWN
EACH END OF "BUNDLE x 2 LONG @ 3" O.C.; oil
OF STUDS CENSTAGERRND OFF DBL.2X8 SYP #2 LEDGER.
PLYWOOD FLOOR
3/4 AS SHOWN SEE BOLT SCHEDULE,
SHEATHING MI 10/S3.1A.
8" CMU WALL
REINF PER PLAN 8" CMU WALLJ_
REINF PER PLAN
• _PER ELEVATION 3/4 /4
3 „
PER ELEVATION
;. O �z N SCREW PATTERN LL3� SCREW PATTERN
,�p I JOIST (SEE mz
O o�¢"J FRAMING PLAN) �O_
it zuw O 0Ln¢
PER ELEVATION w In m I
PER ELEVATION N
-
(2) 2x4 P.T. W/ DBL 2X12 SYP #2 LEDGER. SEE 2x4 P.T. CEILING _ Qa M I -JOIST (SEE
MASONRY NAILS NAILER W/ FRAMING PLAN) j
BOLT SCHEDULE, 10/S3.1A.
@ 12" O.C. MASONRY NAILS
USP SPTH4/SPTH6 BTM. 1 X2 FIRE STOP C 12 O.C.
12, PLATE STRAPS W/ 10d x 1 ; J
I -JOIST I LVL 1X2 FIRE -STOP -
1/2""DGNAILS FL#,7239 SECTION DETAIL SECTION DETAIL
WALL / FLOOR FRAMING, AT I -JOISTS PERPENDICULAR AT I'JOISTS PARALLEL
I -JOIST PARALLEL TO WALL TO EXTERIOR WALL TO EXTERIOR WALL
SCALE3/4"_i'-0'
NOT USED 2 - 3 SCALE: 3/4"=1'-0"
`ry 1 `.
1
l� t
9
Y1
r
k$
N
I
N
Q1
(N
Hi
t
5 NOT USED_ NOT USED NOT USED
i
I
PRE-ENG GABLE TRUSS
2x4 BLOCKING BETWEEN TRUSSES
AT FIRST TWO BAYS 4'-0" O.C. (AT STRAP TRUSS TO PL. PRE-ENG
SHEATHING SEAMS) (BLOCKING ® PRE-ENG'D WOOD SEE SCHED. BELOW ROOF TRUSS
j NOT SHOWN FOR CLARITY) TRUSS (TYP) 24" O.C.
MAX
C '
a
2X4 DIAGONAL BTM. CHORD PER ELEVATION
BRACING. SEE PLAN FOR `— FOR STRAPPING
LOCATION VERIFY PRE-ENG ROOF TRUSS
W/ TRUSS PLAN TRUSS TO TOP PLATE 5/8" GYPSUM BOARD OR 1/2" HIGH
SECURE 2x6 PT PLATE TO BLK A -USP MTW-12 U < 1195 LBS 4x4/4x6 SYP N0.2
E STRENGTH CLG. BOARD
W/ 1/2" DIA. ANCHOR BOLT W/ 2" eE1
WASHER SET IN HIGH
W/ (14) 10d GALV, COMMON SECURE TRUSS TO TOP PLATE wl (2) WOOD POST TO
A STRENGTH EPDXY 6" MIN.
NAILS, 16d TOENAILS SLAB. SEE
EMBED. AT 32" OC MAX. B - (2)USP MTW-12 U < 2390
DOUBLE TOP PLATE SCHEDULE a:
SECURE GABLE TO 2x8 P.T. LBS W/ (14) 10d GALV.
PLATE W/ 12d's 8" O.C. MAX
COMMON NAILS EA. 2x4 OR 2x6 WOOD BEARING BELOW FOR
�j CONNECTION
WALL W/SYP No 2 STUDS SEE FL#17239 �
PLANS FOR SPACING. SINGLE
r` l CONC- POURED BTM- PLATE TO BE PT.2
LINTEL COURSE PROVIDE DBL. TOP PLATE
o^
PROVIDE BLOCKING. '.
.o .
It USP SPTH4 OR SPTH6 BTM
AND TOP PLATE ANCHORS W/ SE GYP. WL, BD.
SECURE BT. PLATE TO SLAB W/
10d x 1 1/2" COMMON NAILS 1/2"x9" WEDGE ANCHOR W/ 2"
FILL ALL HOLES, DO NOT USE TRUSS/WOOD POST CONNECTIONS
CONT.2x4 SECURED W/ (2) 10ds Ca) WASHER SET IN HIGH STRENGTH
TRUSS TO BE INSTALLED C 10'-0" O.C. MAX. 10d x 3' EPDXY 5-1/2':' EMBED. MIN. @ 16" 10a 10b 10C
OC MAX. SCALE: 3/4"=V-0"
GABLE END BRACING W/ PRE-ENG
jGABLE TRUSS @ CMU WALL TRUSS TO POST CONNECTION'
SCALE: 3,4"=V-0" A - USP MTW-12U < 1195 LBS W/ (14) 10d GALV, COMMON NAILS. FL#17244 ^�
• q B - USP HTW-20 U < 2045 LBS W/ (20) 10d VALV, COMMON NAILS. FL#17244
C - USP MUGT/PHD4A U < 3715 LBS MUGT TO TRUSS W/ (4) 10d GALV.
COMMON NAILS TOP; (6) 10d GALV. COMMON NAILS FACE, (12) 10d
COMMON NAILS BACK, (1) 5/8"°A T.R. TO PHD4A AND (10) WS3 WOOD �//�/�
TRUSS CONNECTION @ L.B.W. SCREWS TO POST FL#17240/FL#172419 4t,
9a 9b POST TO SLAB CONNECTION
SCALE: 3/4"=1'-0" A&B - USP PAU44 POST BASE, <U:2,265 G:6,775 W/ 5/8 DIA. x 6" EXP. BOLT FL#17239
USP PAU46 POST BASE <U:2,265 GA3,815 W/5/8 DIA. x 6" EXP. BOLT FL#17239
C - USP HTT4 POST ON SLAB <U:4,465 W/ 5/8" A.B. WITH MIN. 7" EMBEDMENT TO SLAB
& (20) 16d x 2 1/2" NAILS TO POST. FL#17324
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA32901
PH: 321-$02-3591
www.abdesigngroup.com
� AA #. 0003325
CREEKSIDE
LOT #72
ImROJECTIP
04321.200 072RI
4EHB
"2605—HAYDEN"
x GARAGE SWING:
RIGHT
.AGE:
DETAILS
(I —JOIST)
i
b'30 MPH EXP. '
ARCHrrECT
STATE OF FLORIDA
4
MIOH EL C. ANDERSON
AR NO T7305
1INT 190 14
.ATE: 1/ /
SCALE: 1/4"=1'-0" 1
SHEET
3.1B
m
VTT SPACING (1) AT EACH END
AND 6'-0" O.C. MAX.
SIDE VIEW \\L
PRE-ENGINEERED
VALLEY TRUSS CONNECTION
1 SCALE: N.T.S.
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA'32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
W
o
F
V
G]
6y
k q
w
A
F
i
i
s1
CREEKSIDF, e
LOT #72
PROJECT#
O4y3^y2�f1.. 2001072R y
'y"
4EHB
"2605—HAYDEN"
GARAGE SWING:
RIGHT
k`
PAGE:
a�a T
p i
r;
4".
1 60) MI' l EX-f-," f
ARCHiI EC
STATE OF FLORIDA
OCT 17 *19
UCHAEL C. ANDERSON
AR NO 17305
19 10 14 -;.
DATE: / /
SCALE: 1/4" =1' — 0:a°
SKEET
S3.I
551 S. APOLLO BLVD.,,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
CYBIMV. 8GT.
CREEKSIDE
LOT #72
PROJECT
04321.200/072R1
1103DEr.
4EHB
"2605-HAYDEN"
GARAGE SWING:
NV
RIGHT
PAGE:
SECOND
FLOOR
DECK PLAN
20 APH EXP.
ARCHTECT:
STATE OF FLORIDA
L !
EL C. ANDERSCs
2Pla h.,
illNO 17305
DATE: 10/14/DIT 19
SCALE: 1/4"=1'—O"
SHEET
S4
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA32901
PH: 321-802-3591
www.abdesigngroup.com
s AA #: 0003325
F=o
pox
Fu
Y
N ti,
N
L,5
4
P
t
�
r!
O
U4
k�
A
f
4� Q
F
a
l;
�i
d
w
�
xl
F�
t�
x �
A 32 P+
�7
m
3
A3
CREEKSIDE
LOT #72
PROJECT#
04321.200/072R1
MODEL:
4EHB
"2605-HAYDEN" m;
, GAGE SWING:
k RIGHT
r PAGE;
l
SECOND FLOOR
DOWEL PLAN
U160 MPH EXP.0
,R-C-ITECT� -
STATE OF FLORIDA
t p�T
ANDERSON
F"FUNT 1914
DATE: 10 / /
SCALE: 1 /4"=1' - 0"
SHEET
S4.,f
FRAMING NOTES:
1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE
CONCRETE TO WOOD ROOF:
USP HTAt6 W/ (9) 1 Od x 1 1/2" HDG NAILS.
CONCRETE TO WOOD FLOOR:
USP LPTA W/ (10) 1 Od x 1 1/2" HDG NAILS,
WOOD TO WOOD:
USP RT16A OR LUGT2 W/ 1Od x 1 1/2" HDG NAILS, FILL ALL HOLES.
2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER
SCHEDULE. 1
3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE
MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS
ARE TO MATCH CONNECTOR FINISH.
5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL
MANUFACTURER SHOWN IN STRUCTURAL PLANS.
6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND
CLEAR SPAN OPENINGS.
7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4").
8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE
SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE
FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS
LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND
APPROVAL.
9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES
SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED
FASTENER; ZF 72 P8S36, .177" ' x 2 7/8" LONG, WITH WASHER @ 16" O.C.
10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END
UNLESS OTHERWISE SHOWN DIFFERENT.
11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON
RATIONAL ANALYSIS.
12. ALL ELEVATIONS ARE REFERENCED FROM U-0", FINISH FLOOR. UNLESS
NOTED OTHERWISE.
HEADER
SCHEDULE
MARK
SIZ
DESCRI
&
TION
REMARK
(2)
8
BEAM SCHEDULE
INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / B.O.L. = BOTTOM OF LINTEL /T.O.A. = TOP OFARCH /T.O.S =TOP OF SLAB
ABBREVIATIONS E.E. = EACH END, O/C = ON CENTER, F.E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT
MARK
DESCRIPTION
(psi)
SIZE ZE,
REINFORCEMENT
STIRRUPS
REMARKS
BTM.
`TOP
MID
SIZE
SPACING
BB1
MASONRY
3000
8x16
—
(1) #5
(1) #5
N/A
GROUTED SOLID
gB2
MASONRY
3000
8x8
—
(1) #5
—
N/A
—
GROUTED SOLID
1 ♦♦ 8F16-lT/0M/0B 81`16-iT/OM/OB 8F16-1T/OM/OB y
1
1 ♦♦ 2 ®## 1
Cli ♦♦♦
1 ♦♦ �� 1
♦♦ 1
� 1
GT ♦<
♦ — .-
1 1
1 ♦♦♦♦ ,I,
1
1 ♦♦ I� 1
1 ♦ I U.N.O. PROVIDE B82 WHERE 1
1 ♦♦ � ROOF TRUSSES BEAR, 1
♦ TOP OF WALL EL 10'-0" 1
1So1
1
♦♦
+*�
1
1
1
♦♦
♦
}___.�
I�
1
1
1
1
1
�I
♦♦
1
1
1
1
I
♦
♦♦
1
��
1
`
"CAST-CRETE"
SAFE
LOAD TABLE
1
♦�
All
10,
��
##
SAFE LATERAL
LOADS FOR
SAFE GRAVITY LOADS FOR 8" PRECAST
& PRESTRESSED
I1-LINTELS
Be PRECAST '& PRESTRESSED U-LINTELS
COFF
I IPLIFT
LOADS FOR 8"
PRECAST & PRESTRESSED
U LINTELS
. w9
SAFE
LOAD - POUNDS PER LINEAR FOOT
C Any
SAFPL OAD
SAFE LOAD - POUNDS PER LINEAR FOOT
1
I
�� 1
GT
1
TYPE
8FMI3
8F12.0B
OF16.OB
8F20-OB
BF24-OB
8F28-OB
BF32-OB
TYPE
RCMU
TYPE
8FB-iT
8F12.1T
BF16-1T
8F20-1T
BF244T
BF28.1T
BF32-1T
`
LENGTH
8U8
8F8-1B.
8F12-iB
OF16-16
8F20
8F241B
OF28-1B
BF32-iB
LENGTH
SU8
SF8
LENGTH
8FB-z7
SF72-2T
SF18-27
BF2D-2T
BF24-2T
BF28-2T
BF32-2T
#
I
6132
7001•
1
,� ♦♦
1
3'-6" (42")
PRECAST
2231
3069
4805
8113
7547
8974
10394
PI809
3'-6" (42") PRECAST
1025
1024
1598
3' 6"
1569
2655
3524
4394
I
,
,'
2751
5325
6079
1
♦♦
Nt
4'-0" (48')
PRECAST
1966
808
4'-0' (48") PRECAST
765
763
1309
4'-0"
(48")
PRECAST
3060
3615
457�
5325
8D79
,
25931
4605
6113
T547
as7a
1D39a
11107
t363
23Ds
O
1
,
1989
2110
2931
3753
4576
5400
6224
GT
4'-6' (54")
PRECAST
1599
4'-6" (54") PRECAST
592
591
1W3
'(
1
�,
2189
4375
6113
7547 m
8672
10294
11809
� ♦
1349
1438
1999
25B0
3123
3686
4249
�
1016
171`5n)
2276 1q
2838
3399
3961
4522
1
�
', ♦
1
5'-4" (64")
PRECAST
1217
734T{,»
8733p9,
1012709)
5'4" (64") PRECAST
411
411
745
5'4"
(64")
PRECAST
1016
1715
2276
2838
3399
3961
:4522
1
- ♦`
�r
1663
3090
5365
7547091
�
�
1
11 DS
1173
1631
2090
2549
3009
3470
PRECAST
909
1567ry»
2 1s
2593 9
3107ycj
3620 4j
4133 (»
,�
1
T-10" (70")
PRECAST
1062
V-10" (70") PRECAST
340
339
616
F-10"
(70")
929
2080
2593
3107
3620
4133
—_ _— __.
___.
4360
381�
74383 �»
506 �)
1567
' `
1
6'-6"
PRECAST
908
1238
-. 267�7
3480
30
3707(7»
, "
6-6" (78) PRECAST
507
721
490
„
6-6
"
(78)
PRECAST
835 1s
1407ps,
iB6lizn
2329 s
279(>11e1
3251n<,
3712pz
IL .`.
BF16.1 T/OM/..
OB m
1
0
(78")
39Qs0
_
w,
'.
3251
3712
..
m
'� r
■
1
•
(
727 1a
1065(zs,
162E si,
2025 °"
24211 �
28271m)
3228 z4,
III
1 �. r J
1
♦
♦
1
101i
1729
2632
2205
2698
3191
3685
T-6" 10"
(' )
PRECAST
743
8467Np
6472ps,
T-6' 90" PRECAST
( )
424
534
363
T-6"
90"
( )
PRECAST
727
1224
1624.
2025
2426
2827
3228
Q
1
♦
1
1011
1729
2661
3898
5681
1
I 8F161T/OM/OB 8F161T/OMlOB 8F16-1T/OM/OBE
9'-4" (112")
PRECAST
554
sss
11sD
lszs
z684
3466
2818
33oz
9'4" (112") PRECAST
326
512
230
9'4"
(112")
PRECAST
ss1
708(0)
113s„,
1474
19St„'
21571m)
2500(3aj
1
1
-
752
1245
1843
2504
3486
4705p ,
6390pr,
691
862
1318
1643
1969
2294
2619
1
- - - -
10'-6- (126")'
PRECAST
475
535
890
1247
2093
2777
2163
2538
10'-0' (126') PRECAST
284
401
180
10'-6"
(126")
PRECAST
530
575(m,
..916'",
118803)
146'y33)
173603)
2011,33,
�„
♦--1
643
1052
1533
2093
2781
3B430»
4754(45,
530
695
11801s)
1472 (q
1763 z
2055
2346
"..
582
945
1366
1846
2423
3127
4006
474
504 in
800 (3z)
103T0z)
1274M
1513M)
1753(sz)
-
1 V4" (136")
PRECAST
362
11'4" (136") PRECAST
260
452
154
11'4"
(136')
PRECAST
-' - -- -
-
-
I
_
582
945
1366
1846
2423
3127
4006
494
607
1042no)
1372(11)
164:t je,
1915o)
2187(5)
I`
540
873
1254
1084
2193
2805
3552
470 9
458(,,,
724 31
938.3z
11&t )
1369
1585 rz
12'-0" (144")
PRECAST
337
12'-0" (144") PRECAST
244
402
137
124
(144")
PRECAST
540
873
1254
1684
2193
2805
3552
470
550
940,1o)
1302,s,
1560(13,
1818(„)
2075„0)
471
755
1075
1428
1838
2318
2883
418 ,s
386 (z)
607.3u,
785,,)
96400
114300
1323(3,)
13'4" (160")
PRECAST
296
13'4' (160") PRECAST
217
324
110
13'4"
(160")
PRECAST
471
755
1075
1428
1838
2378
2883
428
460
780 IR
11591z4
1418po
165319,
1887(1r)
' 4'-6" (54") PRECAST
1zo7
z6ao
2707
3375
4043
4711
5379
1207
2040
2707
3375
404:1
4T71
5379
�•j
14'-0' (168") PRECAST
"
279
- 424
706
1002
1326
1597 2127 2630
14'-0' (168") PRECAST
1697 2127 2630
205
293
100
14'-0" (168") PRECAST
38413
358(21)
560.20
724(m)
889 0
1054 )
1220(w
442
706
1002
1326
410
425
717 (9)
1063(zU
1358p3)
1582p2)
1807,21,
14'-8" (176") PRESTRESSED
N.R.
NR
NR
NR
NR
N.R.
284
-.
91
14'-8" (176") PRESTRESSED
239
334pn
520(,
6721z9
825
978 9
1131(w
NR NR 'R
14'-8" (17611) PRESTRESSED
2245 2517 2712
458
783
1370
1902
246
395
663
980 (2o)
130:ta
1518
1734,m7
o-1
NR NR NR
15'4" (184") PRESTRESSED
2056 2320 2513
i
15'4" {1'84")PRESTRESSED
N.R.
NR
NR
NR
NR
N.R.
259
83
15'4" (184") PRESTRESSED
224
313 »)
4860,)
627.1zp.
769p9)
911 (z9)
1054ps)
412
710
1250
1733
230
368
616 »
9081po)
124(1pa,
1460a7,
1668 ps)
1T-4" (208")PRESTRESSED
N.R.
NR
NR
NR
NR
N.R.
194
64
tT4" (203") PRESTRESSED
187
263 19
405 ps)
521'(27)
638 (R)
756 in
873 (21)
"
�
NR NR NR
1T4' (208") PRESTRESSED
1609 1B49 2047
300
548
950
-1328
192
308
508 (61
740'. p9)
tOD5,z7
1271 1
1473 3t
t9'-4" (232") ,PRESTRESSED
N.R.
NR
NR
NR
NR
N.R.
148
52
19'4" (232").PRESTRESSED
162
229 (17)
348 ps)
447'.(21)
547 ps)
647 ps)
747 ps)
'i
NR NR NR
19'4' (232") PRESTRESSED
1282 1515 1716
235
420
T50
IN7
166
263
429 (a)
623 (13)
841 im)
105900>
1227(30)
21'-411 (256") PRESTRESSED
N.R.
NR
NR
NR
NR
NR NR NR
21'4" (256") PRESTRESSED
1114 1359 1488
N.R.
125
42
2t'4" (256") PRESTRESSED
142
204 (1s
307 (23)
393'(23)
480 in,
568 v)
655 (m)
iB0
340
598
846
142
232
373 p,
537. p7
7211zs1
905 p91
1048(z9)
22'-0" (264") PRESTRESSEDEN.R.
NR
NR
NR
NR
N.R.
116
40
22'-0' (284") PRESTRESSED
137
197 (1s)
295
379 m
462 z3
546 3
639 m
NR NR NR
22'-0" (264") PRESTRESSED
1047 1285 1399
165
315
550
784
137
223
358 p
513 (17)
888. (zal
883 p6)
999 (m)
24'-0" (288") PRESTRESSED24'-0"
NR
NR
NR
NR
NR NR NR
(288") PRESTRESSED
884 1092 1222
N.R.
91
33
24'-0" (288') PRESTRESSED-,
124
119 (1a)
267 p1)
342 p1)
416.. p1)
492 p0
567 (zz)
129
250
450
554
124
202'
319 p)
455 0s)
606(zs)
757 R7)
B76 p7)
(#) THE NUMBERS IN PARENTHESIS
REDUCTIONS FOR GRADE 40 FIELD
ARE PERCENT
ADDED
REBAR.
W THE
REDUCTIONS
NUMBERS
IN
FOR GRADE
PARENTHESIS
40
ARE
FIELD ADDED
PERCENT
REBAR.
ALL VALUES TAKEN FROM "SAFE LOAD TABLES" BY CASTCRE�E MAY 2015 EDITION - PREC
T PRODUCTS BY OTHERS TO MEET bR EXCEED VALUES STATED ABOVE
-ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS - PROVIDE
MINIMUM 4" OF BEARING PAST EAbH SIDE OF WINDOW OPENING
PRODUCT
DIVISIO
CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION-CASTE-CRETE
ACCEPTANCE#:16-0126.03
SECOND FLOOR LIFT BEAM PLAN
Ah
551 S. APOLLO BLVD.,
SUITE 202 I°
MELBOURNE, FLORIDA32901
PH: 321-802-3591
www.abdesigngroup.com
h
w
�y
0.
a y
q
W
ca �
A
I
r
,-0
B;
F
CREEKSIDE
LOT #72 15
c'
04321.200 072R1 '
4EHB
"2605- HAYDEN"
GARAGE SWING:
RIGHT
SECOND
FLOOR
LIFT BEAM
PLAN
pr y jp7I'TJE
F) x
STATE OF FLOC a=(:M
MICFtAtEL C. AND � N
Ali b0 -T,3S
D'ATEr 10/14/19
SCALE: 1 /4"=1' — 0"
SKEET
L®
FRAMING NOTES:
1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE
CONCRETE TO WOOD ROOF:
USP HTA16 W/ (9) 1 Od x 1 1/2" HDG NAILS.
CONCRETE TO WOOD FLOOR:
USP LPTA W/ (10) 1 Od x 1 1/2" HDG NAILS,
WOOD TO WOOD:
USP RT16A OR LUGT2 W/ 1 Od x 1 1/2 HDG NAILS, FILL ALL HOLES.
2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER
SCHEDULE.
3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE
MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS
ARE TO MATCH CONNECTOR FINISH.
5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL
MANUFACTURER SHOWN IN STRUCTURAL PLANS.
6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND
CLEAR SPAN OPENINGS.
7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4").
8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE
SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE
FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS
LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND
APPROVAL.
9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES
SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED
FASTENER, ZF 72 P8S36, .177" ° x 27/8 LONG, WITH WASHER @ 16" O.C. .
10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END
UNLESS OTHERWISE SHOWN DIFFERENT.
11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON
RATIONAL ANALYSIS.
12. ALL ELEVATIONS ARE REFERENCED FROM 0'-011, FINISH FLOOR. UNLESS
NOTED OTHERWISE.
TRUSS MANUFACTURER / ENGINEER NQLES:
1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 1_815 SHALL BE
FABRICATED W/ A 2x6 BTM. CHORD (MIN.)
2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS
WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT
SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES.
3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO
TRUSS CONNECTIONS.
4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN.
MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN
COLUMN SCHEDULE
MARK
SIZE &
BASE PLATE OR
REMARK
DESCRIPTION
REINFORCEMENT
4X6 (3Y2"x5Y2")SYP.
USP HTT4 W/518" DIA
5/S3.tA
WD-1
PT., WOOD POST
x 5" EXP. BOLT
CONNECTOR SC[ I [DUE[ -
I I CONTROL DATC:01-05-12
Miiek USP
SIMPSON:
MiTek USP
SIMPSON ;
DES
UPUH
GRAVITY
DES.
UPUFI
GRAVITY
FASILNLR
FASILNLR ."mx16
IIIA IS
1625
MUAA%
1450
(9)1Dd X 11/2' 1-PLY, 1])lbd2PLY,CM6C04'
(8)10d x 1112' 1- PLY, (W),l'6tld. PLN„
(211TA16-18
2430
R)META-16
1985
(12110d x 11/2'1-PLYLMBLD4
(10110d x 11/2"1-PLY, EMBED 4"
1900
(10)16d 2-PLY,. LMBL04" -
H1ALU
1820
HEI A-20
1910
(10) W 11/2', (6)36d __CMBE 4' ,.,
(9)lBdxll/2"4MPLY,
HH 16d 2-PLY, EMBED 4"
y
(2)1IIA20
2430
(2)1ILIA 20
2035
(12110dx 11/2'. 1-PLY, EMBED 4"
I(5)1/4166
(10110d
11/2"1-PLY,EMBEDW'
�WOOD
C
2260.
UST -2
'2150.
BLKoo
'x 3�Wed8cBaltFA" rl, WO6p(16)IBd
{7))1/4"x2L1/4MJ
11 EN, (16) 16d
2430
BE AL20
2480
(lb)-10dx11/2,A PLY AU LRNAIL USE OF(21111A 10 ACCLPIABLL
(181 10
x11/2, 1 PLY ALI LRNAI L USLOF(2) I ILIA20:ACCLPIABU
4175
MGI+
3965
(1)5/8"A.T31 IN HIGH STRENGTII EPDXY(MIKU'CMBED), 122) 10d TOWOOD)
(1)5/8
TR IN I IIGI I STRENGTI I EPDXY (MIN. 12' EMBED).(22) 10d TO. WOOD
9790
IIGI-2+
1098U
WOOD (9) IN, MNSONRY(2)3/4'ATR -
(2)3/9
TR IN I IIGI I STRCNGTI IEPDXY (MIN 11'EMBED),(16) 1pd TO WOOD
9860
HGT-3+
10530
WOOD (9) lOd, MASONRY (2) 3/4'AAA
(2)3/4
.1 H I N H I G H SI R LNGI H E PO%Y(M IN 12 EMBED), (16) 10d 10 WOOD
r1lucli
3525
LGT3-SD52.5
3285
CONC(4)3/8'%5AI WMW-Bok+ Anchor WOOD(12) WS25
(12)SOS
J4"x3 10 GIRDER,(4)3/8" x5111 EN HDIO WALL
153UPARALLLLIOWALL
PCRPCNDINIAR TO WALL
L1 A2
1210 PARALLH OWALL14TO
1210 PLRPLNDIr_JLARIU
WAIL
(10)10dx 10'(10110d
13/L"
41]5
VG1
4940
(1)S/8-A:T.ft INIIIGIISTRCNOTII CPDXYI((M""IN.12'CMBCDI,(4)10d TOP/16110d FACE/(12) 10d 0ACK OF TRUSS
(1)5/8"
T.R. IN I IIGI I STRENGTI I EPDXY(MIN, 12T EMBED 116)5%1/4N37185
(2)VGI
7185
(2)5/8'A.T.R IN HIGH STRCNGTI I EPDXY(JEEL 2' EMBED),(8) 10d
(2)5/8--1
T.R. IN I IIGI I STRENGTI I EPDXY (MIN 12" EMBED), 132) SIBS 1/4"0
MTW 12
1195
MTS-12
1000
(14) 10d x 11/2', r14) 101
(14)10d
(16) 10d)
11/2"
I ITW 16
1260
1 ITS-16
u5o
(16) 10d% 11106) 1LM
11/2
H1W20
1530
HIS-20
1450
(24)1Ed%11/Y, 0)3M
(24)10d
11/2 "
H1W24
1530
IIIS-24
1450
124)10dIII 1/Y, )10d
(24)10d
11/2
LS1A 12,
930
LSIA-12++
925
(10130d
(10110d
LSTA 18++
1235
ESTA-18++
1215
(14110d
(14)111d
MSTA-18++
1310
MSTA 19,
1315
(14)10d
(141 UXI
MS1 A-24++
1640
MSIA-24 r+
1640
(18)SBd
(1811Ud
MS1 A-M++
2065
M51 A-30 ++
2050
(22)l0d _.
(22110d
Q<
MblA-36«
2065
MST A-36r
2050
-
(26110d `. -
(2611DI
KST1236
3890
M511-36
3800
IN) 1WX 11/2'
(36)lod
11/2
KTS1249
5140
MSTI-48
5065
148110d%1])2
(48)IOd
31/2
LF1 A5
1210.
HE
950 -.
(16)8dxllW,(1(r)8d)
(8) Sd TO
PLATES, (8)8d TOSTUD9
SR124
103D
SP4
885
(6) l0d TO MILES (6) 10d TO PLATE
(6)10dx
11/2TO STUBS
MP34
5251N F1@160%
A34
5151N F1@
16W"
(4)Edx 11/2' 10 ELAM,(4) 8d x 11/2" 10 VOSI
(4)Ed. 11/1
10 BEAM, (4) 8d x 11/2" 10 POS1.
HHCP2
ROD
H02
645
(1011Wx 11/2' 10 TRUSS. (10) IW X 11'' 10 PIAIL
(12)10d
11/2.1
Ni1fiA
1380
HIM>114U
(9110tlx 11/2-TOT RUSS, Q ELI x 111A?0 PLAIL"
(:us) 10d)
11/2"
MUG115 & PI IU4A
4125
1 Iu4
VG & I U
4565
810d TO TRUSS 10 WS3 WOOD SCR STO POAW/ 58'TIIRE4D[DROD
ill .1 6lY/
16 SDS
1 I
OD (10)-SOS TIIREADCD ROD WASI CRIB PLY
4'x3"TO WO / / 2.NUT5 /
/ l 1 / ,U /
MU(iT15&PI1D4A
1 4125
VGl&IIB]3
4940
(28)10d TO TRUSS, (10) WS3 WOOD SCRFIWSTO POSTW/5/8'TIIREADED ROD
(16)SDS 1/4"x3"TO WOOD, (33/4"STUD BOLTS WITHREADED ROD, (2) NUTS/WASI ICR/ZPLY
PAU"
2535
6]]5 `
ABU 44Z
2200
6665
(1)5/8'A.I.X. IN HIGH SI RENGI H LPDXV"(MIN. r EMBED) IN CONC,(12)16d 10 W 0D
(1)5/8 A I. R IN H IG H 51 RENGI H EPDXY, (MIN. T" LMBEU) IN CONC,(12)16d 10 WOOD
PAUEB
2380
16005
ABU 66Z
2300
12DD0
(1)5/8' A.I.R. IN HIGH SI RLNGIII LPDXt(MIN.]" LMBLB)INCONC,(12)lWlOWOOD
(1)5/8"A.1.R. IN III GI I Si RLNG111:EPDXY, (MIN ]" 1MBLD) INCONC,(12116d IDWOOO
Lt519++i
1205
L1119.
B40
(1)3/4-A.I.R INIIIGIISIRLNG111LP0%YI(MIN.]"LMBLD)INCONC,(8)1Dtl 10 WOO -
(1)3/4".AA.R.
IN I IIGI I SI RENGI I FLPDXY,(MIN ] EMBED) INCONC,(811Ud 10 WOOD
L152U8+ro
1100
L11208 ♦♦+
1500
(1)3/4-A.1.R.INIIIGIISIRLNG111LPDXYj-(MIN.2'LMBL011N CO NC,I10)lOdxll/FO WOOD
(1) 1121, AA.R.
IN I I G I I Si RLNGI I I LRPO l (MINT EMBED.) IN CONC,(10) 10d 10 WOODP
S
111145
4160
11714
4235
(1) 5/8' A.T.R.IN IIIGI StRENGTIICPDXY$MINJ'EMBED) IN CONC, 118) 16dX21/2"
(1)5/8"4
T. R. IN HIGH STRENGTH EPDXY (MIN T'[MBED,),INCONC.,126)16d%21/T'
U
Z"
11R15
5005
IITb
5090
(1)5/8'A.1.0.1N HIGH SI RENGIH EVO%V(MIN. T'EMBEU) IN CONE, (26)16tlX21%1':�
(1)5/8'.A.1.R.
IN HIGH STRENGTH EPDXY (MIN 7"EMdE6,)IN CONE, 126)16d %11/2"
c"
UVHUllf
14395
IT IDQI1 SDS
25+
11810
(1)1"A.1.R.IN IIIGII SIRLNG111 EPDXY(MIN.10"EMBED) INCUNC. (24)W53 W000SCRLWS
4) 1'
IN IIIGI151RLNGTII EPDXY, (MIN:10"LM0L6.1NNNG, (24)SCS /. x2N"WOOD SCREWS
PI IDSA
6525
HU28
6(+:45
(1)5/8"A.B. IN I RON STRENGTI I EPDXY, (MIN 7' EMBED) IN COI (14) W53 WOOD: SPEWS
(1)2/8
B IN II IGI I STRENGTI I EPDXY, (MIN. 2 EMBED I IN CONC,(3) 3/4 STUD BOLTSTO WOOD
TDX9
7820
(1)7/8"A.B. IN HIGH SI RENGI H EPDXY, (MIN.J"EMBEO)IN CDNC.(3)2/B $I UU BOLTS IU WOOD
NFM35%12U
2580
J130
MBIIA
3.56/1115
34]5
5330
(1)1/2"'I-BOLI WMIN B"EMBED&NOI, UIIHAN 4" FROM EDGE OECONCW/ 3/4" CIA II W RAMSEI/REDHEAD
DYNA BOLT SLEEVE ANCI FOR OR CQ W/MIN 5'CMBCD INSTALLED IN PACC(14)10d ATJOIST
EPDXY ,(
IINCE6,755"EMBEDMENT I IN CM,U.IOR, (1)3/4" AAA IN HIGH SI RLNGIH
INRbNS'IGH Sl RLGII IN
1 110d 10 BEAM
IIUS4121F
3060
2710HOM)
HUSC411
(W000)
3635
Il86D(1H1Y)
(SO) 16d TOIICADER,{10)16tl TO WOOD
(10)16d011[AD[R,
(10)16d TO WOOD
3325 25°e)
BD65 f125'M1
N
ZK .
IIU4IUIF (CMU
1950.
-5000
ICMU)
CMU)
1800
4500
WOOD. US BU)3/1WSI 5CRLw9,(10) SUtl 10
WOOD. USP I2U)i/16""TAPPER+, (10) 10d 10 WOOD
(18)1/4
2-3/4..1I1LN 19 PER #LANGLhOONU, NO)30d10 W003;
Q
Z
HD210-21F(CMU)
1950
5000
IIUC2IU-2
(CNI U)
1800
4500
(19)1/4"'x3' WS3 SCREWS, 10d 10 :
WOOD. USP (2013/16"" I APPER , (10) 10d 10 WOOD.
(18)1/4"Ix2-3/4"
111 EN 19 PER FLANGE) IU CMU,(10) 10d lO WOOD,
H0210-31F(CMU)
1.950
5000 'lIUC2103
(CMU)
1800
4500
(19)1/4""x 3' WEB SCREWS, (10) 1061O. 11
WOOD. USP (20)3/1G TAPPER, (10) 10d TO WOOD
(18)1/4
23/11 II TEN (9 PER FLANGE) IUCMU,(10)]WHOWOODi
LGUM26-2
2125
6065
LGUM262SM
1430
5595
(4)3/8"X4"WMBc Bolt, Anchors, WOOD(4)W53 WOODSCREWS
(4)3/8x
111 LN HD ANCHORS(1 PER FLANGL)IQ CIVIL, (4)1/4%2.1%2 SMSCRLWSIOWOOLI
r2
U U
ROOF FRAMING PLAN
SCALE: 1/4" = V-0"
En m
uo M .-
U U 0
1 551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
mmommmmI
g svBDIV. & LOT:
CREEKSIDE
LOT #72
a 1'in
(iili 4
x, f�
PROJECT* I1
04321.200 /072R1
MODEr.
4EHB
"-HAYD
,, 260/5���gmE�wN'
F$ V9
T=�IGE:
i
ROOF FRAMING .'
PLAN AND
NOTES
10 MPH EXP. C
ARCHrrECT-
STATE OF FLORIDA
_ rs
I
P,
N
' OCT 1,r �1i9
MICHAEL C. ;%)NE)F7(a_sQ1;
PRINT DATE: 10 14 19
SCALE: 1/4"=1'-0" h
b
.MEET'
I
YI
)Tj'
GENERAL NOTES:
ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. MAXIMUM AGGREGATE SIZE SHALL BE 3/4".
T'..-^`Fan .... :',. fuffiu vu`�.. .,.. .c ."..--.._, ,.°��i%+'dFh.�i,' - „x-r:`L;...,C„ � �•�un
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND
WOOD;.
"A"
AR HITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS: CONSULT
PROVIDE 6°!° AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER
NON -BEARING WOOD WALLS TOP PLATES &STUDS CAN 8E SPF.
. GABLEENDAR
HITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN
O O O O 0
ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS; FBC-R 2017, 6th EDITION
ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 3/4
ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING,
a 0 '2 O O 3 0 2 0 0 3 a
3 -
AO 318-14, BUILDING CODE. REQUIREMENTS
PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON
CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. ED = 1100 PSI AND A MODULUS OF
- 0 0 0 0 0 0 -
FO STRUCTURAL CONCRETE, ACI 530-13/ASCE 5-13 AISI SPECIFICATION FOR THE DESIGN OF
ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE
COD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASCE 7-10 AND AISC SPECIFICATIONS
DRAWINGS. SEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE
-PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES
0 O
O 0 O 0
ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND
FORM -WORK:
SHALL BE RATED TO RETENTION LEVELS OF 0.25PCF OF A BORATE PRESERVATIVE TREATMENT: DISODIUM
CORROBORATE TETRAHEDRAL (DOT) WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY
0 0
0 O 0
SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE_ ON THE PROJECT,
FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS,
REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE.. NAILS, SPIKE, BOLTS USED
O
O 0
EXCEPT WHERE A.DIFFERENT DETAIL IS SHOWN.
AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347,
W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT
B
"RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK.
CONTAINS MORE THAN 112' OF HEARTWOOD.
0 0
ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE
O O O 0
O O
DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT
EXCLUSIONS FROM THESE PLANS:
MINIMUM NAILING PER FBCR`2017, 6th EDITION. SEE NAILING SCHEDULE ON PLANS.
. 0 0 0 0
TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE .AFFECTED PART
WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS
-
0 0
OF THE WORK.
ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL. DEPENDING
PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER
` 2 1 2 2 1 2 '
THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING
ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED. BUT ARE BY OTHERS.
SYP #2
q• "A - A'
1S COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY. TO DETERMINE ERECTION PROCEDURES AND
UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE.. SEAT PLATES SHALL BE PROVIDED
0 0
SE@UENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
WELDED WIRE MESH:
AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES.
0 0 0 0
DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
0 O O 0 0
TEMPORARY BRACING,GUYS OR TIE -DOWNS.
WELDED WIRE MESH, SHALL BE ASTM At85, GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE ACI
WOOD TRUSSES:
0
TYPICAL DETAILS, MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL BE
O 0
O 0 O O 0 OO
THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION
SUPPORTED WITH. 2' CHAIRS SPACED T-0" OC, EACH WAY..
TO BE S-GRADEDAND UMBER AND ITS FIN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR
STRESS -GRADE LUMBER AND ITS FASTENINGS'BYTHE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND.
O OOO OO OO
REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS.
SEALED BY PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS.
O O O 0
O O O O
DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR
REINFORCING STEEL:
CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0. "AND E
036 B MANUFACTURED FROM STEEL
O O O O O O O
TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
REBAR SHALL BE ASTM A615 GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A615
MEETING THE REQUIREMENTS OF ASTM A446, GRADE A; AND SHALL BE HOT -DIPPED GALVANIZED.
C? O O O O O
I
GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE
0 50 0 0 00 2 00
DESIGN LOADS:
W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI. STANDARDS AND SPECIFICATIONS.
DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL
2
Q 0
CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL
STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND "TPI/WTCA BCSI 1"
0 17, O .. 0
0 O OO 0 O
ROOFLIVE LOAD FLOOR: LIVE LOAD 40psf
AND VERTICAL BARS SHALL LAP 6x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEER'S
COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED
0 00 2 2 0 0 00
20 psf TOP CHORD non concurrent
REVIEW.
TYP. MIN LAPS: SHALL BE AS FOLLOWS #4BAR - 25" #6 BAR - 36"
WOOD TRUSSES.
O O 0 O O O 0 O 0 0 0 O O 0
0 psf BTM CHORD -non-concurrent
#5 BAR - 30" #7 BAR - 42"
TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF
\/
0 0 0 0 0 OOOO
PROVIDE 36" x 36" CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEEDETAILS
LOCATIONS WITH GUSSETS; CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR
O O O O
0 0 0 0
DEAD LOAD DEAD LOAD
15 TOP CHORD 20 TOP CHORD l
FOR ADDITIONAL INFORMATION.
INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI A58.1-1982.
0 0 O 0 0 0
pef psf
0 Q
L
(7psf w/ ASPHALT SHINGLES) (10 psf w/ No GYPCHETE)
ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING,
HURRICANE. STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
'P O 0 0
0 0 0 0 0
10 psf BTM CHORD 5 psf BTM CHORD
THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH
O 0 0 0 0
3 O O O O O "a 2 O O O O 3 a
DEAD LOAD TO RESIST WIND UPLIFT: 10psf
MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE
CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT
0 0 0 0 0- O 0 0 0 O
BALCONY LIVE LOAD 60'.psf
WALL..
TRUSSES/GIRDERSTO COLUMNS AND WALLS FOR APPROVAL,
"A-
.> HIPRODE>
WIND: 'DEAD LOAD SPEED =17) MPH SECOND GUST STAIRS LIVE 40 psf
RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL
ROOF &FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TORE USED AS GUIDE FOR BEARING
S
ROOF" WIND DESIGN PRESSURES
(ASCE 7 10 (BBC EXPOSURE C, RISK CATEGORY 11)
S
INTO INTERSECTING WALLS AND HK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE.
HOOK
DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE, TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL
NET (GROSS) ASCE 7-10
LIVE LOADS: UNINHABITABLE ATATTICTIC WITHOUT STORAGE: tOpsf, UNINHABITABLE ATTIC WITH LIMITED
-
LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT
ZONE 1 = PSF (49.48)
STORAGE: 20psf, HABITABLE ATTICS. AND ATTICS SERVED WITH FIXED STAIRS: 30 sf BALCONIES (EXTERIOR)
P p O ES ( IOR)
DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS
AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE
' ZONE2 = 39.48 PSF (49.48)
39.48
AND DECKS: 40psf,. GUARDS AND HANDRAILS: 200psf, GUARD IN -FILL COMPONENTS: SOpsf, PASSENGER
WITHOUT THE APPROVAL OF THE ENGINEER. -
STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL
ZONE = 67:16 PSF (77.16)
GARAGES: SOpsf, ROOMS OTHER THAN SLEEPING ROOM:40 sf, SLEEPING ROOMS: 30
p psf, STAIRS:
PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION
"A"= 4'-0-0 " END ZONE DISTANCE
40 sCLE
p
MASONRY:
PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED ANDSEALED BY A FLORIDA
.
BASIC WIND SPEED: 160 MPH
MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE
LICENSED PROFESSIONAL ENGINEER:.
WIND EXPOSURE: "C"
SHOP DRAWING REVIEW: r
"SPECIFICATION MASONRY STRUCTURES" (ACI 500/ASCE 5/TMS 402, BUILDING. CODE REQUIREMENTS FOR
MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS
THE HURRICANE
U CANE STRAPS SPECIFIED ON THE WALL. SECTIONS AND PLANS ARE PROVIDED TO FACILITATE TI I.i_
RISK CATAGORY: II
SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT
PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE.
CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS
APPLICABLE INTERNAL -
OF THE CONTRACT DOCUMENTS ONLY: IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
PROVIDED BY THE TRUSS. ENGINEER,
PRESSURE COEFFICIENT +- 0A0
COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIME NSIONS,`ETC.
Y
- CONCRETE MASONRY BLOCK ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW OC
THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE
ALL;, SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT.
MANUFACTURED IN CONFORMANCE WITH ASTM 0-90, GRADE f'm = 7500 P51. BLOCK SHALL BEPLACED USING
OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-10 COMPONENT
CLADDING
AND CLADDING WIND LOAD PRESSURES. THE DELE ATE ' TRUSS ENGINEER SHALL BE RESPONSIBLE FOR
G
DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM
RUNNING BOND UNLESS OTHERWISE NOTED, LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE
-D
ALL T TRUSS NNE
SS O USS CONNECTIONS.
ROOF DIAPHRAGM
OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED
PLACING CONCRETE FOR IN -WALL COLUMNS. dROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH
U FOR ASPHALT SHINGLE ROOF, USE MIN 7/16"
WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT
ASTM C-47fi, AND SHALL PROVIDER MINIMUM C®MPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS UNLESS
ALL SHEET METAL FRAMING CONNECTORS SHOWN ®N THE PLANS SHALL BE "USE STRUCTURAL
O.S.B. OR 1/2" CDX EXT. PLYWOOD, FOR
ROOF/ WALL/ FLOOR
DOCUMENT WILL GOVERN OVER THE
S SHOP DRAWINGS CHECKED, UNLESS OTHERWISE SPECIFIED IN
WRITING BY THE ARCHITECT.
SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8"
COURSE AGGREGATE, AND SHALL BE PLACED W/ A SLUMP OF 8" TO 10". USE ONLY MECHANICAL VIBRATION
-
CONNECTORS" BY USE, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS
CEMENTITIOUS TILE AND METAL ROOFING, USE
I
WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE
MIN. 5/8 CDX EXT. PLYWOOD, WITH 8d RING
i
TO CONSOLIDATE GROUT.
LATEST CATALOG.
SHANK GUN NAILS AT 4" O.C. AT SUPPORTED SHEATHING
FOUNDATION/ SITE PREPARATION' ; .
TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE
PANEL EDGES AND Sd RING SHANK GUN NAILS
FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf, FOOT,INC�,.r
PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS
AT 6" O.C. AT INTERMEDIATE SUPPORTS. SEE FASTENER SCHEDULE
EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95 % OF -THE-
SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO
DETAIL.
-MO DIFIED'PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D j557rTREATALL
CELLS TO BE FILLED.
ROOF SHEATHING TO GABLE ENDFRAME USE
SOIL FOR TERMITE PROTECTION-
8d GUN NAILS @4"O.C.0 EDGEWISE 2x4
1
FILL CMU CELLS SOLID WITH. GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL
BLOCKING ALL PANEL JOINTS W/ IN 4' OF GABLE NAIL SCHEDULE
U
THE:OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY
REINFORCING.
Fnln
SU I CESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE
SIZE
TYPE
MIN. LENGTH
MIN. DIA.
SHANK
TENSILE STR.
SHANK
8d
RING SHANK,
2 1/2"
0.120"
170,000
RING
RINGS
SCREW SHANK
PER I
PER INCH)
8d
SCREW SHANK
2 1/2"
0.120"
PNEUMATIC
SCREW -NAILS
GE -TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE -- . ;, LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O.
CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE
MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL STRUCTURAL STEEL:
BE MADE BY THE GEO=TECH. ENGINEER. THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE
C NGRETE: SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS,
9TH EDITION, BY THE:AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM
CO CRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: A36, Fy = 36 ksi FOR ANGLES, PLATES; AND W-SHAPES. STRUCTURAL, TUBING SHALL BE ASTM A 500,,. GRADE B,
o" Fy = 46 ksi. STRUCTURAL. PIPE SHALL BE ASTM-53, GRADE B, TYPE E OR S, Fy = 35ksi. TUBE AND PIPE
2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP.
3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5".S'TROCTURAL TERRACE SLAB
1. NAIL SIZE PER ASTM F1664
TOP CORD BLOCKING AT 4'
ANCHOR BOLTS AT THE COLUMN HALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL
:I
INTERNATIONAL STAPE NAIL & TOOL
2. INTER O
0. C- MAX. IN FIRST 2 FRAMING
+'
,CO<�TRACTORSHALL
SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX -PRIOR TO s
25-NBASES
BOLTS
OTHER BOLTS SHALL BE ASTM A325-NBOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL
„
CONCRETE
PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5" +/ PRIOR TO THE ADC.ITION OF PLASTICIZER
BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD.
ASSOCIATION (ISANTA) ESR 1539
SPACES AT EACH END.
."-
RAFTER OR TRUSS'.
CO
CRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 301 ANDASTM C-94ORMEASURING; MIXING, TRANSPORTING, ETC.
ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J-BOLTS ARE TO BE STEEL.
ROOF SHEATHING
CO
ETE. TICKETS. SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS
CR E
ADE
ED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY REASON THERE IS A
I,
DE
Y IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES,. THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE
EXTERIOR SHEATHING ''"'•
I
RES
ONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY NON
USE 1/2" CDX OR 7/16" O.S.B. PLY WITH 8d RING
COMPLIANCE WITH THE ABOVE
SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES
AND 8d RING SHANK GUN NAILS 4" O.C. TOP &
Z
REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS,
`
BOTTOM PANEL AND 8d RING SHANK GUN
0
A.
3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS):
NAILS .AT6" O.C.ATINTERMEDIATE 'SUPPORTS
OR 7/16"'ZIP SHEATHING SYSTEM (INSTALLED
w..3
m
-. B.
FOR CONCRETE EXPOSED TO EARTH AND/OR.WEATHER:
1-112'FOR#SAND SMALLER
PER MANUF. SPECS.) SEE DETAIL.
T FOR #6AND LARGER
c
C.
FOR CONCRETE NOT EXPOSED TO WEATHER.
-
-,
BUILDING LENGTH
L
3/4" FOR SLABS WALLS AND JOISTS
1-1/2" FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS
,`�
1
ROOF SHEATHING LAYOUT
AND ENDWALL BRACING
FOR GABLE END FRAMING
8d RING SHANK GUN NAILS @ 4" O.C.
TOP & BOTTOM EDGES
z
co
FASTENER SCHEDULE
z
WINDOW
AND
DOOR BUCK
FASTENERS
FASTENER
w
Z (�
APPLICATION
SIZE
TYPE
SPACING, -__
REMARKS
APPLICATION
SIZE
TYPE-
SPACING
REMARKS
�
(� LUC
G SHANK GUN NAILS
8d RING
1x2 PT FURRING TO
CASE HARDENED COIL
B" O/C
GARAGE DOOR BUCK
14"CIA
TAPCON MASONRY
--
11i2"EMBEp.,.4"END DIST..
z
@ 6" O.C; IN FIELD
MASONRY / CONC.
NAIL 1. 1/2" LONG
---
- --
TO MASONRY/GONG
— - —
NO WASHER
FASTENER
8" O/C
11/2" EDGE DIST.
'V
SGD, AL. EXT. DOORS
1 x PT, SEE NOTE fi
CASE HARDENED COIL
NAIL 1. 1/2' LONG
9" O/C
STAGGERED
WINDOW/DOOR/ FASTENED
INTO MASONRY/GONG.
GARAGE DOOR BUCK
TO MASONRY/GONG
-1/2" DIA W/
WASHER
EXPANSION
24' O/C
4" EMBED., 4" END DIST.,
= O
3 EDGE DIST
'IT-
0
-
WINDOW BUCK
CASE HARDENED COIL
9'O/C
WINDOW/DOOR/FASTENED
METAL STRAP TO
CONTACT THIS ENGINEER FOR SPACING.
aU
Z
tx PT, SEE NOTE 6
NAIL 1 112" LONG.
STAGGERED
INTO MASONRY/CONC.
MASONRY / CONC.
REQUIREMENTS Q S
J
Q
"6
EXT. SWING DOOR
(2( 3/16"DIA
'TAPCON
18" O/C
1 1/2' EMBED, 8"END.
NON -BEARING WOOD
1Y2"
EXPANSION
4" EMBED. 4" END
",
BUCK 2x PT SEE NOTE 6
NO WASHER
FASTNER
DIST., 1 1/2" EDGE DIST.
WALL TO CONE SLAB
W/ WASHER
BOLT
24 O/G
V'
DIST., 3" EDGE DIST.
Q
Z. w
Z J
TYP.
F
EXT. SHEATHING ATTACHMENT OR ROOF SHEATHING (O.S.B
zx PT WINDOW BUCK
Z Q
J W
(3 LL
r E3-1
I O BE O I HVCTU HAL GRADE)
PT TO SYEEL COL.; SEE
0.1 WIPASH21i8"
W/ WASHER
9'G/C.
STAGGERED
4- END. DIST,712'
EDGE DIST.
NOTE 6
Y CaJ
U)
J
NOTES
Q
Z
1 STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS
U
- Z
`L
2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND / OR NOA
_ O
Z m Z
Cf)-
Z W
3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED
= w C7
4. RAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN
5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOAOR THE SPACING DETAILED ABOVE -
Z
LU
(�
C
6. WINDOW AND DOOR BUCKS SHALL BD AS WIDE OR WIDER AS THE DOOR OR. WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. h>k MEMBERS ARE NAILED AND
LijU �
Sd RING SHANK GUN NAILS 12" O.C. IN
2x MEMBERS ARE SECURED W/ TAPCONS OR PAFTOTHE SUBSTRATE.
00
2'
U N U
FIELD or 8d x 2 1/2" SCREW SHANK
Z
� O
00 LU
PNEUMATIC SCREW -NAILS @ 12" O- N
FIELD
AA
V
z
r
a
a
00
TYP.
3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS
�..=_�:-thN3ie`?T. ..,., a:`- or "'�.�"F, �di'fTC. �`Rs, .Tip.: •:__,..SQL-� „iin�-`,a .,::... ".: 3..: .. q'�3
t�:�%'��.a �'±Y.RX^.;
.
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321-802-3591
www.abdetigngroup.com
AA #: 0003325 �3
I„ W
i7
W
o-3
C3
0
I
o
A,
ky
q
A
4�
a
Cl
f
1
i
I
r,.
1751
F
I
4
�
m
m1
a U
4
I�
640
d
sURIr 8e LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
�.. ODEL•
,a
4EHB
2605-HAYDEN"
,ARAGE SWING:
rl
RIGHT
PAkGE:
r
R
�pp
DETAILF
Y{
,-
Ni
5{
60 MPH EXP. C:;
ARCHrrECT.
-ATE OF FLORIDA
I
J
l^
MICHAEL C. ANLZERSO
APR NO 17305
IffINT
_DATE: 10/14/19
SCALE: 1/4"= V — 0"
II SHEET _ r
S I
3
Planning & Development Services Department
Building & Regulations Division
Procluct KevIeW Attldavlt
.................. -- ......................... ......... ------------------ -- ................... ....... ............ ................... ........... ........ -- .................... ............... - .......... .... ......
....... ---------
........... ........ ......
FL # or Miami -Dade
......... ....................... --- .. ............ . ......... ........... ...... 11 ----- ......... ................................... ........... - ................. ........ . ....................
FLORIDA PRODUCT REVISION EXPIRATION Product Model # Manufacturer Glass Description method of Attachment Building Design
Pressure
Product Design
Pressure
APPROVAL REVISION DATE
1/4"
concrete screw 611 edge distance @ head, 4" edge distance @ jamb, 4" each side
of
transom centerline to bucking. fastener spacing @ 15" o/c max. @ head and jamb.
FL5891.2
R6 12/3112021
Swing door
Smooth Star
Thermo-Tru
N/A
Min, embedment of all anchors to be 11/4" (+36) / (-47)
(+67) / (-67)
--------- -- -- ------I--
-------------- --- - -- - ---------- ------------ ---- - -- ------------------ ---
------------- - - --------------- -
----------------- -- - ---------- ---- --- --------
-------
— -----------
----__-__--
Type 1: 3/16" or 114" ELCO Ultracon anchor 6" max, from corners, 113/4" a/c at jamb,
16" @ head. 11/4" embedment, Type 11: 3/16" or 1/4" ITW concrete tapton anchor. 6"
max. from comers, 7 1/4" o/c at jamb, 101/4"@ head, 11/4" embedment, Two
additional tapcons midspan and one at lower frame required vertically each side,
FL16103,1
R12 4/3012020
SH Window
Ply Gem 1500
Ply Gem
Non Impact Install
per manufacturers recommended requirements. (+38) (-49)
(+50) (-50)
Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max, from corners, 14�'o/c at iamb, 10"
@ head. 11/4" embedment. Type II: 3/16" or 114" ITW concrete tepcDn anchor. 6"
max, from comers, 8 1/2" o/c at jamb, 6" @ head. 11/4" embedmenL Eight
additional tapcons top and bottom required bontontally, one midspan vertically each
F1.16100.1
R6 6/30/2020
Vertical Mullion
Ply Gem 1500
Ply Gem
Not) Impact
side, Install per manufacturers recommended requirements. N/A
N,,A
Type 1: 3/16"cirl/4!'ELCO Ultracon anchor 6" max, from corners, 14" o/c atjamb, 16"
---
@ head / sill, 11/4" embedment. Type ll: 3/16" or 1/4" ITW concrete tapron anchor.
6" max, from comers, 8 1/2" o/catjamb, 10 1/2" @ head / silL 11/4" embedment.
Five additional tapcons top and bottom required horitontally,two midspan vertically
FL16104,2
R5 11/30/2022
Fixed Window
Ply Gem 1500
Ply Gem
Non Impact
each side. Install per manufacturers recommended requirements, (+38) (-48)
�+55) (-55)
1/4P concrete tapcon anchor. 2 1,/2" minimum edge distance. 6" max c/o from comers
and 20 3/4" max o/c elsewhere top, vertically and bottom, 21/2"min embedment.
FL146�4,1
R3 12/31/2019
Sliding Glass Door
Builders Series 4780 w/
Ply Gem
Non Impact
(+33) 1 (-41)
(+50) (-So)
Sill Riser
1/4" concrete screw 6" edge distance @ head, 4" edge distance @jamb, 4" each side
of transom centerline to bucking. Fastener spacing @ 1511 o/c max. @ head and jamb,
FL20461.17
R4 12/211/2019
Opaque single
Smooth Star
Therma-Tru
N/A
Min. embedment of all anchors to be 11/4" (+36) / (-47)
(+47) I (-47)
door with transom
x 2-3/4" HIM sleeve anchors 6" from ends 22" O/C
FL161
RiO 12/3112020
Double Garage
16.2x7 73 W6
Clapay
N/A
(+29)/ (-35)
(+36) (42)
Door
Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" di a.
heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per
shingle placed 6 -1/8" above the butt edge, approx. V and 13" from each end and 1/21'
F1,700iij
RIO 12/21V2620
Roof
IKO Cambridge
N/A
above each cutout, Drive nails straight so that nail head is flush with, but not cutting (+36) (-47)
N/A
into shingle surface.
Miami -Dade approved corrosion risstant tin caps and 12 ga. 1-1/4" annular ring
R4, 12/31/2020
Imerweb
N/A
shank nails spaced 6"O,C. at all laps and three staggard rows fastened 12" D.C. in the
N/A
FL15216,1
(PENDING APPROVAL)
Underlayrnent
Rhino U-20
field,
.................... . .... . .. ... .....
........................... ........... . ... ........ ..
.......... . . ------------ - -
.. . ....
.....
. . ...........
Position Vent Flange beneath loosened shingles aligned w/ deck opening. Apply ASTM
D 4586 orASTM D 3409, Type I roofing cement/mastic to the underside of the vent
flange at both the inside and outside perimeter and to continuously surround and seal
the flange. Slide the top and side flanges of the vent underneath the shingles and
allow the bottom flange to lie on top of the shingles. Attach the vent with galvanized
or stainless steel roofing nails having a min 12 ga shank, min 3/8" diameter head and
sufficient length to penetrate through the sheathing {ring shank nails shall be used in
the HVHZ). Nails shall be located I" from the edge of the flange and 8"O.C. along all
Fll
R2 9/9/2026
Off Ridge Vent
OFF -RIDGE VENT WITH
TAIVICO
N/A
four sides of the vent. All exposed fasteners shall be seated with roofing N/A
N/A
BAFFLE
cement/mastic. all loosened shingles shall be adheared down with roof
cement/mastic. Refer to and follow ALL Manufacturers installation instructions, AOR
is not responsible for Errors, Ornssions or interpritations of this Installation Method.
Apply Roofing Sealant on all seams inside the Roof Collar. Apply Roofing Sealant
along all (4) sides of the bottom of the Vent Flashing, Install in location under
shingles to roof deck, Fasten Base Rang to Decking using 11/4" Ring Shank Nails.
Fasten Base Flange w/(1) nail ea corner @V'frorn edge. Fasten each Side of Base
flange using (3) nalles spaced nominal 5" apart and V from edge. Fasten Top and
Bottom using (3) nails spaced a nominal 5" apart and V from edge for a total of 22
FL3792
R11 9/1612021
Roof Vent
770-D
Lomanaco
N/A
nails. Seal all seams and nail heads and loose shingles. Refer to and follow ALL N/A
N/A
(alternate)
Manufacturers installation instructions. AOR is not responsible for Errors, Omissions
orinterpritations of this Installation Method, AOR is not responsible for Errors,
Ornssions or misinterpretations of this Installation Method.
FL24161,1
NONE 12/31/2020
soffit
Variform Soffits
PlyiGem
N/A
F1.24161.1 (+31.6) (-38.8)
(+77.0)/(-73.6)
1/4' x 20 stainless steel or ELCO Parielmate with minimum embedment @ 13/4" in
Hurricane Panels
Hurricane Storm
concrete / masonry, 2 1/2" min, edge distance, 12" o/c max. spacing. Can be headed
FLI6291.1
R2 12/3112019
Less than 6' span
24 GAGE
panel MFG.
N/A
screw or all thread but with wing nuts. N/A
+or - 20 p.s,f.
......... --- ...... --.- ......
........... .. ..... ........... - ........
....... ...
..........
. ........ --- ....... . - ...........
..
TIC x 20 stainless steel or ELCO Panelmate with minimum embedrivirit @ 13/4" in
concrete / masonry, 2 112' min, edge distance, 12" o/c max. spacing. Can be headed
FL14943,1
R2 12/31/2019
Hurricane Panels
24 GAGE
Hurricane Storm
N/A
screw or all thread but with wing nuts. N/A
+ or - 20 p,s,f,
6� span or more
panel MFG.
Install per manufacturers recommended requirements.
FL17147:1
R3 6/27/2019
ZIP System
Wall Sheathing
Huber
N/A
N/A
Sheathing
*1
75
CK I
SONT;;ZZOL 1-"4,TEF T! i'a
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA 32901
PH: 321802-3591
www.abdesigngroup.com
AA #: 0003325
U T =4 I
BDIV. ac LOFN,�
S f 11 I-Auc -1 1;lf
COTNT
MA.TER PA
PROJECT#
MODEL:
FTINE LE
GARAGE SWING:
f.
PAGE:
r ARCHITECT=
STATE OF FLORIDA
tt
1 ZAP a
OCTU" "" 'll" R
LMICHAEL a. AND R � 1 ENW�4 �
AR NO 17305 V
DATE; zr 07/1.6/19
SCALE: 1
STIENT Flea
:0
GENERAL NOTES
SITE WORK
TIMBER
1.
ALL WORK DONE UNDER THIS CONTRACT SHALL BE !IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR)
1.
REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT).
1.
ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED
6th EDITION, (2017) . ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESE DOCUMENTS ARE UNDER
HEREIN:
FBCR 6TH EDITION (2017) UNO.
2.
REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES,
A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL)
SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL
B. NATIONAL FOREST PRODUCTS ASSOCIATION:
2.
WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR
DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HERERSEE LANDSCAPE DRAWINGS FOR FINAL
I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION
BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY
FINISH GRADES, PLANTING AND IRRIGATION.
C. SOUTHERN PINE INSPECTION BUREAU:
THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS, THESE OPENING PROTECTIONS SHALL BE
L. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER
DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2.
3.
ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE
D. TRUSS PLATE INSTITUTE:
ARCHITECT.
I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 1-2014)
3.
DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK
E. APA - THE ENGINEERED WOOD ASSOCIATION:
PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
PERFO
4.
NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN THE HORIZONTAL
I. ENGINEERED WOOD CONSTRUCTION GUIDE
DISTANCE FROM THE NEAREST EDGE OF THE FOOTING.
F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS
4.
THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION
OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK.
5.
ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAN GRANULAR FILL. PLACE IN 8" LAYERS
2.
ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED.
THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE
THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR
AND COMPACT TO 95% MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE BUILDING SITE
3.
MINIMUM NAILING PER CHAPTER 6 WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS.
CONTRACT DOCUMENTS, OF WHICH
SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS.
FABRICATION OF THE WORK.
4.
NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION.
5.
THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES,
6,
COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED.
OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES
5.
WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1.
7.
DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE)
6.
THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING, THE CONTRACTOR
1
6.
MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM: AREA SHALL BE 8 FT . SQ.
SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING
8.
EXCAVATIONS TO BE A MINIMUM OF T- 0" BEYOND NEW FOOTING LINE.
CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED,
PLUMBING
9.
THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE
1.
SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL,
7.
DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS
REQUIREMENTS.
2.
WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX "A" (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS.
3.
CONDENSATION LINES SHALL BE MINIMUM 3/<" PVC (SCHEDULE 40), INSULATED WITH''%" AMAFLEX.
8,
THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER.
10.CTO
RACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY
4.
SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH.
COMPLIES WITH ALL LOCAL CODES HAVING JURISTICTION, INCLUDING ALLAPPLICABLE STATE, CITY AND
5.
ALL CLEANOUTS SHALL BE FLUSH WITH GRADE.
9.
NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC, UNLESS SPECIFICALLY DETAILED.
TY BUILDING AND ZONING CODES. IF CONSTRUCTED IN A FLOOD ZONE, SOIL CONDITIONS MUST BE MODIFIED
ACE THE FINISHED FLOOR ELEVATION MIN V-0"ABOVE THE BFE, PER FLORIDA BUILDING CODE.
6.
NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES.
Q
7.
SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005 2
GARAGES AND CARPORTS
11.
SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE,PERMITTED SEPARATELY BY ENGINEERED SHOP
8.
FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903.
1.
-GARAGE DOOR
DRAWING.
9..
THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE,
A. ENGINEERED FOR MIN WIND LOAD, LISTED ON COVER SHEET
10.
DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2.
B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER
12.
TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES,
C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER
BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION
EXTERIOR WALL COVERINGS
2.
DIRECTLY INTO A ROOM USED FOR SLEEPING
AS PER SECTION R302.5.1: OPENINGS FROM A PRIVATE GARAGE G R C TLY
LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE
1.
ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR
PURPOSES SHALL NOT BE PERMITTED. OTHER BETWEEN THE GARAGE AND RESIDENCEBE INOTPED WITH
APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE
THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301. 2 AS MODIFIED BY TABLE
)
TEELDOORSLL
HEOPENINGSINTHICKNESS, B LESS THAN '
SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CO S
BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT:
R3012(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1:5 TIMES THE DESIGN PRESSURE(
1-318 INCHES THICK, OR 20 MINUTE FIRE -RATED DOORS
"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES.
TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF
EXTERIOR FINISHES
3.
AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE
AGRICULTURE AND CONSUMER SERVICES."
1,
WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %" THICK, OVER FRAMED WALLS
DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM N0.26 GAGE (0.48 MM) SHEET STEEL 1"MIN. RIGID
APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS
ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE
" _
THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE.
GARAGE.
Ilk
2.
STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH
ASTM•C926 & ASTM-Cl063-12a.
4.
AS PER SECTION R302:6 &.TABLE R302.6: THE GARS E SHALL BESEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT
o-
3.
LATH & ACCESORIES PER ASTM-C-1063-11A & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITEDTO:
LESS THAN 1/2 -INCH GYPSUM -BOARD APPLIED TO TIDE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMSALL BE
_ _
ALL STUCCO CONTROL JOINTS _ _ _ KICK -OUT -DETAILS
SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD (�R EQUIVALENT.
-
�`'
LL FLASHING - HORIZONTAL LATH AND PAPER DETAILS
1"WHERE
THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE
� -�
PIPE PENETRATION DETAILS
-- -- VENT PENETRATION DETAILS
PROTECTED BY NOT LESS THAN 1/2-INCH GYPSUM Ei®ARD OR EQUIVALENT.
WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS
CASING BEAD DETAILS DRIP EDGE DETAILS
CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS
-
WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS
WINDOW FLASHING DETAILS
4,
SHALL BE INSTALLED PER ASTM-C1063-15AAND R703.7,
•
FIRE RESISTANT CONSTRUCTION
,-
UNDER STAIR PROTECTION:
-
1.
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED
ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. R302.7.
EXTERIOR CEILINGS
1 EXTERIOR CEILING TO BE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING
MEMBERS. THE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1
1/4" TYPE "W" DRYWALL SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS) .
CONSTRUCTION OBSERVATION
CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF AB DESIGN GROUP'S
SERVICES FOR THIS PROJECT.
IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW
OF THE BUILDERS/ CONTRACTOR'S PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL
BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND
FOR CONSTRUCTION OBSERVATION.
I
551 S. APOLLO BLVD.,
SUITE 202
MELBOURNE, FLORIDA32901
PH. 321-802-3591
www.abdesigngroup.com
AA #: 0003325
F
W
:w
V
n w
z
F
N
Q
p
Q
o
u-
F
a
C
0
�
ri
0
E
ti
a
N
SLTHDIV 8e LOT:
CREEKSIDE
LOT #72
PROJECT#
04321.200 072R1
MODEL
4EH13
"2605-HAYDEN"
GARAGE SVfMG:
RIGHT
]PAGE:
GENERAL
NOTLEXP.JC
60 MPH
VSTATE
HrrECT-.
FFLORIDA
OCT 2 7 2020
MICHIAEL C. ANDERSON
AR NO T7305
PRINT DATE: // 10 14 19r:;
SCALE: 1 /4"=1' - 0"
SIMET {
GN