HomeMy WebLinkAboutPlans Examiner Review FormACCP.. ayca,a�giao-.;�soran�ca Contractor Florida Breeze Mechanical License # CAC1814113 Building Plan # County, Town, Municipality, Jurisdiction Header Information 'REQUIRED ATTACHMENTS' Manual A Form (and supporting worksheets): or MJfAE Forme (and supporting worksheets): OEM performance data (heating, cooling, blower): Manual D Friction Rate Worksheet: Duct disidbutfon system sketch: Honlie Address (Street or Lot#,. Block, Subdivision) winter Design Conditions Outdoor temperature 42. °F Indoor,temperature ..70- OF Total heat loss 39666' Btu/h Summer Design Conditions Outdoor temperature . 90 OF Indoor temperature . 75 OF Grains difference 61 A-Gr @ 50 % Rh Sensible heat gain 3.3$64 BtuM Latent heat gain 8811 Btu/h Total heat gain 42614 Btu/h Form RPER 1.01 8. Mar 10 ATTACHED YesOX Yes ❑ NonXX. Yes XQ NoEl Yes'Q No 0, Yes ❑ Now Building Orientation (Front door.faces) South North; East; West, South, Northeast, Northwest. Southeast; Southwest Number of bedrooms 5 Conditioned floor area .2605. Sq Ft Number of occupants 6: :Windows Eave overhang depth Roof �.. Q, Ft Internal shade Blinds, drapes, etc Numberof skylights Heating Equipment Data Cooling Equipmer t:Data Equipment type Heat pump Equipment type Heat pump Furnace, Heat pump, Boiler, etc. Air Conditioner, Heat pump, etc Model 25HBC548A`030* Model 25HBC548A*030* Heating output capacity 45500 . Btu/h Sensible cooling capacity 38435 8tum Heat pumps = capacity at winter design outdoor conditions Latent cooling capacity, 9314 Btu/h Auxiliary heat output capacity. Btu/11 Total cooling capacity 47749 Btu Design airflow "CFM External Static Pressure,(ESP) IWC Component Pressure Losses,(CPL) IWC Available Static Pressure.(ASP) IWC ASP = ESP - CPL . . . Longest supply duct: Longest return duct: Total Effetstive Length.(TEL) Friction Rate: Friction Rate = (ASP x 100) TEL Eave Depth Window Blower Data Heating CFM 1.839..CFM Cooling, CFM 1839 CFM Ft: Duct Materials Used (circle)• Trunk Duct: Duct board,`Flex, Sheet metal, Ft Lined sheet metal, Other (speclfy) — Ft Branch Duct: Duct board, Flex,,Sheet metal, IWC Lined sheet metal, Other (specify) Contractors Printed Name Kristin:Ketly Date 5115/2019 Contractor's Signature Reserved for use by County, Town, Municipality, or Authority having jurisdiction. ' The AHJ shall have the discretlon to accepYRequired Attachments printed from approved ACCA software -vendors, see list on -page 2 of instructions. ' ' ' If abridged version of Manual J.is used for Idad calculation; then verify residence meets' requirements, see Abridged Edition Check ist on page 13 of insfritctions, Form generated by ACCA-approved Manual J Eighth Edition version 2 Elite Software Rhvacprogram. Air Conditioning Contractors of America Manual S (Residential Equipment Selectidh) Project Information Name: City: State:. Altitude: lJ Altitude Adjustment: 1.00 'diollit Cooling Design Information Outdoor Design Temp:. 81 IF db Summer Outdoor Design Temp: 43 IF db (Winter Indoor Design Temp: 75 °F db 50 %RHF-6-3--1 IF wb Manual u Load calculations Total Load Sensible Latent SHR Heat Loss 42674 33864 8810 0.794 Airflow Calculations Design TD for Airflow 17 Design Sensible CFM 1811. OEM Information . Manufacturer: Icarrier Furnace Model #: 7 AFUL= .Coil or Fan -Coil Model #: FX4DN(B,F)049L Condenser Model #: 25HBC548A`030*I SEER: 15.0- HSPF: 8.50 (A) Manufacturer's Cooling Performance:Data - Lower Return Air Outdoor Temperature = 95 (F db) Entering Coil Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @ Rated RA Temperature 65 .1 47;660 32;990 14.670 0.6922 Rated CFM @ Design RA Temperature 1400 F77E 1 45,984. r 5,166 F1.0,818: 0,7647 Rated CFM @Rated RA Temperature 60 _ 43,470 36,430 5,04b 0.8841 -(B) Manufacturer's Cooling Performance Data Higher Return Air Outdoor Temperature = 95 (F db) Entering Coil Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @Rated RA Temperature 65 - 49,120 36,450 12.670 : 0.7421 Rated CFM @ Design RA Temperature 1900, F748,132 38,536 9,602 O.t3005 Rated CFM @ Rated RA Temperature 1 46.656 . 41,650 - : 5.,000. U928 ,vialwiaciulci s wuony renurinance uaua tmrerpo[area). . Design Return Air Outdoor Temperature = 95 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR 37- ,81 99 0.7944 Excess Latent Capacity Calculation + 504 -F— 504 , Capacity @ Design CFM / RA (F wb) 18T0.9 63:. 47,749 38,435 9;314 0.805 Equipment Capacity as a % of'Design 119.896/6 113.50% 105.72% Manutacturers Heat Pump Data Capacity Capacity Balance Supplemental @ 47 IF db @ 17'F db Point Heat Required 46.280 .26,680 .-23.8 -15.87 FManufacturer's Furnace Data Input Output Desired Calculated