Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Empress Condo - Elevator Upgrade - revision
SHEET:DRAWN BY:CHECKED BY:JOB #:PROJECT #:DESCRIPTIONCADDATEMARKSYSTEM:CHKISSUE DATE:ISSUE LOG:Revisions shown with # symbol 18" x 24" - Arch C Size 315 South 7th StreetPhone: 772 672-4636Fort Pierce, FL. 34950Fort Pierce Engineering, Inc.Dependable Mechanical, Electrical& Plumbing DesignFax: 772 672-4637C.A. No. 28173DRAWING INDEXLEGENDSPROJECT DIRECTORYJOHNSON CONTROLS CONTACTSSCOPE OF WORKAPPLICABLE CODES & STANDARDSDEVICE TAG LEGENDABBREVIATIONS LEGENDSYSTEM SEQUENCE OF OPERATIONSFIRE ALARM SYSTEMELEVATOR UPGRADEEMPRESS CONDO·FA: = FACP (NON-NETWORK)·#: = NODE NUMBER·T#: = TRANSPONDER NUMBER·#:T# = NODE:TRANSPONDER NUMBER·N#: = NAC EXTENDER NUMBERDEVICE NUMBER·D# = DOOR HOLDER CIRCUIT NUMBER·F# = FIRE PHONE CIRCUIT·H# = AUDIBLE (HORN) CIRCUIT NUMBER·M# = IDNET LOOP NUMBER·P# = POWER CIRCUIT NUMBER·S# = SPEAKER CIRCUIT NUMBER·V# = VISUAL CIRCUIT NUMBER·Z# = ZONE NUMBER·(L#) = IDNET ISOLATED LOOP NUMBERBRANCH / ISOLATED LOOP DESIGNATOR:CIRCUIT DESIGNATORPANEL DESIGNATOR1:T2:V12-1(L1)SiteEMPRESS CONDO9600 S OCEAN DRIVEJENSEN BEACH, FL 34957General ContractorNICOLS CONTRACTING9250 BELVEDEREROYAL PAL BEACH, FL 33411Johnson Controls District - 2621830 PARK LANE SOUTHJUPITER, FL 33458PHONE: 561-277-4140FAX: 561-747-7307SERVICE: 561-277-4140PHONE: Sales RepresentativePETER KEPCHARPETER.KEPCHAR@JCI.COM561-277-4193PHONE: Drawings Prepared ByHOWARD SEVRINSKYHOWARD.SEVRINSKY@JCI.COM561-277-4192PHONE: Drawings Reviewed BySCOTT DIRKSCOTT DIRK@JCI.COM561-277-4156OCCUPANCY TYPE(S):SPRINKLER PROTECTION:R-1 RESIDENTIAL GROUPBUILDING IS FULLY SPRINKLEREDMODIFY EXISTING FIRE ALARM SYSTEM: TO INSTALL NEW HEAT DETECTORS IN THE ELEVATOR LOBBIES AND ELEVATOR MACHINE ROOMS, ALONG WITHRELAYS AND MONITOR MODULES FOR ELEVATOR RECALL.AS SHOWN ON DRAWINGS.CONNECT NEW DEVICES TO EXISTING INITIATING DATA LOOP.ALL NEW WIRING TO BE CLASS B.THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. ITIS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK.JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECKWITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS.FLORIDA FIRE PREVENTION CODE, SIXTH EDITION (2017) -NFPA 1, FIRE CODE, 2015 EDITION -NFPA 101, LIFE SAFETY CODE, 2015 EDITIONFLORIDA BUILDING CODE, SIXTH EDITION (2017) -INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION -NFPA 70, NATIONAL ELECTRIC CODE, 2014 EDITION -NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2013 EDITIONAC=ABOVE CEILINGAFF=ABOVE FINISHED FLOORAHJ=AUTHORITY HAVING JURISDICTIONALM=ALARMANN=ANNUNCIATORBMS=BUILDING MANAGEMENT SYSTEMC=CEILING MOUNTEDCD=CANDELA RATINGDET=DETECTORDGP=DATA GATHERING PANELE=EXISTING TO REMAINEOL=END OF LINEEPO=EMERGENCY POWER OFFER=ELEVATOR RECALLFAA=FIRE ALARM ANNUNCIATORFACP=FIRE ALARM CONTROL PANELFATC=FIRE ALARM TERMINAL CABINETFBO=FURNISHED BY OTHERSFCC=FIRE COMMAND CENTERFSD=FIRE SMOKE DAMPERFTR=FIRE ALARM TRANSPONDERH=HIGH HUMIDITYHT=HEIGHTHVAC=HEATING VENTILATION & AIR CONDITIONINGIMS=INFORMATION MANAGEMENT SYSTEMMAX=MAXIMUMMIN=MINIMUMN/A=NOT APPLICABLENAC=NOTIFICATION APPLIANCE CIRCUITNDU=NETWORK DISPLAY UNITNEC=NATIONAL ELECTRIC CODENFPA=NATIONAL FIRE PROTECTION ASSOCIATIONNIC=NOT IN CONTRACTNPU=NETWORK PROCESSING UNITNTS=NOT TO SCALEPAP=PRE-ACTION PANELRC=EXISTING TO REMOVE AND COVERRD=EXISTING DEVICE TO BE RELOCATEDRL=RELOCATED DEVICERR=REMOVE EXISTING & REPLACE WITH NEWSCC=STATUS COMMAND CENTERSLC=SIGNALING LINE CIRCUITSMK=SMOKESUPV=SUPERVISORYTAC=TRUEALERT ADDRESSABLE CONTROLLERTOS=TOP OF SHAFTTRBL=TROUBLETS=TAMPER SWITCHTYP=TYPICALUON=UNLESS OTHERWISE NOTEDVCC=VOICE COMMAND CENTERVT=VALVE TAMPERW=WATTAGEW/=WITHW/O=WITHOUTWF=WATERFLOWWG=WIRE GUARDWP=WEATHERPROOFXP=EXPLOSION PROOFFIRE ALARM SYMBOL LEGENDSYMBOLDESCRIPTIONBRANDMODELBACKBOXWIRETYPEPANELS4100ES FIRE ALARM CONTROL PANEL, 120 VACSIMPLEX4100-9111SIMPLEX CABINETN/AINITIATING DEVICESADDRESSABLE STANDARD HEAT SENSOR W/REMOTE LED OUTPUT BASESIMPLEX4098-9733 HEAD4" SQ, 1-1/2" D WITH4098-9832 ADAPTER PLATEM4098-9789 BASEADDRESSABLE PHOTOELECTRIC SMOKE SENSORW/ STANDARD BASESIMPLEX4098-9714 HEAD4" SQ, 1-1/2" D WITH4098-9832 ADAPTER PLATEM4098-9792 BASEHEAT DETECTOR RATE OF RISE 135 DEGREEWEATHERPROOFTHERMOTECH302-ET1354" ROUND WP ELECTRICALBOXZMODULES AND RELAYSINDIVIDUAL ADDRESSABLE MODULESIMPLEX4090-9051SINGLE GANG 2-1/2" DW/COVERMRELAY IAMSIMPLEX4090-90024" SQ. 2-1/8" D W/ DBL.GANG COVERMRISOLATOR RELAYSPACE AGERIC-2SINGLE GANG 2-1/2" DW/COVEREND-OF-LINE RESISTOR 3.3K (EOL)SIMPLEX4081-9002END-OF-LINE RESISTOR 4.7K (EOL)4081-9003END-OF-LINE RESISTOR 6.8K (EOL)4081-9004END-OF-LINE RESISTOR 10K (EOL)4081-9008FACPZAIMWPAOM10KRSACCEPTABLECABLE TYPESFIRE ALARM WIRE LEGENDFPLR FPLP THHN TFFN OUTDOOR ** C.I.CIRCUIT DESCRIPTIONCONSTRUCTIONGAUGECIRCUIT PROPERTIESMIDNETUTP SOLID18 AWG60µF MAX TOTAL LINECAPACITANCEXXRRELAY2 COND. STRANDED14 AWGXXXXZZONE CIRCUIT2 COND. SOLID14 AWGXXXXCONDUIT SIZEMAX CONDUCTOR AREACONDUIT SIZEMAX CONDUCTOR AREA1-1/4"0.598 SQ INCH*3/4"0.213 SQ INCH*1-1/2"0.814 SQ INCH*1"0.346 SQ INCH*2"1.342 SQ INCH** 40% CONDUIT FILL PER N.E.C.STP = SHIELDED TWISTED PAIRITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEMINSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODELTHAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLEUPON REQUEST.LAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\jdirks\Johnson Controls\Project Electronics - 262-WestPalmBeach\4 Residential\Empress Condo\Elevator Upgrade\FA-001.dwg1/11/2021 11:35:40 AM JDIRKS 262:619390203SCOTT DIRKHOWARD SEVRINSKY8/20/20FIRE ALARM SYSTEMEMPRESS CONDO9600 S OCEAN DRIVEJENSEN BEACH, FL 349571830 PARK LANE SOUTH JUPITER, FL 33458 PHONE: 561-277-4140 SERVICE: 561-277-4140 FAX: 561-747-7307 DISTRICT - 262FA-001COVER SHEETJOHNSON CONTROLS © 2021REV 1EMPRESS CONDOELEVATOR UPGRADE© Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.GENERAL NOTES1.THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OFCONDUITS IS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGESSHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.2.SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJORDEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SOAS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE.3.CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS INCIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH AREAFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.4.A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FORINSTALLATION.5.THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20ABRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIREALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BEPERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT.6.UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSONCONTROLS NO LATER THAN 7 DAYS AFTER FINAL TEST.7.THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER.8.DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICALREPRESENTATIVE.9.ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TOPROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THEFIRE ALARM INSTALLER.10.THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOFASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED.11.INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED ANDNON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS'FOR SPECIFIC CODE REFERENCES.12.ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES.13.FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIREALARM WIRES IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWERLIMITED WIRE.14FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPEFPLP.15.FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLESINSTALLED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR.16.FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WETLOCATIONS.17.FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCEAPPLICABLE ELECTRICAL CODES, WHERE APPLICABLE.18.ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.19.ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE.20.ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.21.120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.22.MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS.23.EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY; HOWEVER, ANYEXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. JOHNSON CONTROLSMAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS.IMPORTANT NOTICE TO USER: This information may not be sold or transferred to any third party, used on other projects or additions to theproject for which it was prepared, or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use orreuse of altered files by the user or any third party and such use will be a user's sole risk. User shall, to the fullest extent permitted by law,defend, indemnify, and hold Johnson Controls harmless from any and all claims for loss, damage or injury arising directly or indirectly from anysuch unauthorized use.SYSTEM OUTPUTS ACTUATE COMMON ALARM SIGNAL INDICATOR ACTUATE AUDIBLE ALARM SIGNAL ACTUATE COMMON SUPERVISORY SIGNAL INDICATOR ACTUATE AUDIBLE SUPERVISORY SIGNAL ACTUATE COMMON TROUBLE SIGNAL INDICATOR ACTUATE AUDIBLE TROUBLE SIGNAL ACTUATE APPROPRIATE LOCATION INDICATOR ACTUATE ALL AUDIBLE EVACUATION SIGNALS ACTUATE ALL VISIBLE EVACUATION SIGNALS UNUSED DISPLAY CHANGE OF STATUS TRANSMIT ALARM SIGNAL TO SUPERVISING STATION TRANSMIT SUPERVISORY SIGNAL TO SUPERVISING STATION TRANSMIT TROUBLE SIGNAL TO SUPERVISING STATION UNUSED RELEASE ELEVATOR FIRE DOORS MAIN FLOOR ELEVATOR RECALL ALTERNATE FLOOR ELEVATOR RECALL ELEVATOR HAT FLASH ELEVATOR SHUNT TRIP FAN SHUTDOWNCTRL UNIT ANNUNCIATIONNOTIFICATIONFIRE SAFETY CONTROLSYSTEM INPUTSABCDEFGHIJKLMNOPQRSTU1HEAT SENSOR/DETECTORXXXXXXX2MAIN FLR. ELEV. LOBBY SMOKE DETECTORXXXXXXXXXX3ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR)XXXXXXXXXX4ELEVATOR MECH. ROOM HEAT DETECTORXXXXXXXX5ELEVATOR MECH. ROOM SMOKE DETECTORXXXXXXXXXX6ELEVATOR SHAFT HEAT DETECTORXXXXXXXX7ELEVATOR SHAFT SMOKE DETECTORXXXXXXXXXX8ELEVATOR POWER MONITORXXXXX9FIRE ALARM AC POWER FAILUREXXXX10FIRE ALARM SYSTEM LOW BATTERYXXXX11OPEN CIRCUIT OR GROUND FAULTXXXX12CLASS B NOTIFICATION CIRCUIT (NAC) - SHORTXXXXSheet List TableSheet NumberSheet TitleGeneral Information (FA-000 Series)FA-001COVER SHEETRisers (FA-200 Series)FA-201RISER DIAGRAMTypical Details (FA-700 Series)FA-701WIRING TYPICALSSITE PLANNSCALE:N.T.S.SITE PLAN1 1-11-2021 SCD CB CHANGES PER FIELD COMMENTS 1 MMMMMMMMMMMMM1ST FLOOR2ND FLOOR3RD FLOOR4TH FLOOR5TH FLOORAIMM 1 - 52FL ELEVATOR LOBBYWPZZ6.8KAIMM 1 - 63FL ELEVATOR LOBBYWPZZ6.8KAIMM 1 - 74FL ELEVATOR LOBBYWPZZ6.8KAIMM 1 - 85FL ELEVATOR LOBBYWPZZ6.8KAIMM1- 96FL ELEVATOR L O B B Y WPZZ6.8K6TH FLOOR7TH FLOOR8TH FLOOR9TH FLOOR10TH FLOOR11TH FLOOR12TH FLOORPENTHOUSEAIMM1-107FL ELEVATOR LOBBYWPZZ6.8KIDNet - M1IDNet - M1IDNet - M1IDNet - M1IDNet - M1IDNet - M1IDNet - M1AIMM1-118FL ELEVATOR LOB B Y WPZZ6.8KAIMM1-129FL ELEVATOR LO B B Y WPZZ6.8KAIMM1-1310FL ELEVATORLOBBYWPZZ6.8KAIMM1-1411FL ELEVATORLOBBYWPZZ6.8KAIMM1-1512FL ELEVATORLO B B Y WPZZ6.8KIDNet - M1IDNet - M1IDNet - M1IDNet - M1IDNet - M1IDNet - M1AOMPRIM1-19ELEV MACHIN E RMRAOMALTM1-20ELEV MACHINE RMRM14TH FLOORAIMM1-1614FL ELEVATO R LO B B Y WPZZ6.8KIDNet - M1AOMM1-22ELEV MACHINE RMSHRRRAOMEWLM1-21ELEV MACHINE RMRAIMM1-23ELEV MACHINE ROOMTO MONITOR SHUNT TRIP ZM1-24TOP OF ELEVATOR SHAFTTOS4100ESLOCATED IN 1FLLOBBYEXISTINGFACP2 PAIR TELCOCAT5 CABLE ETHERNET DROPTERMINATE W/RJ-45 FEMALEJACKRJ-31X JACKSUPPLIED BY ECTO TELEPHONEMOUNTINGBOARDTO TELEPHONEMOUNTING BOARD2 PAIR TELCORJ-31X JACKSUPPLIED BY ECLINE 2LINE 114' RJ45 CABLE (2080-9047)SUPPLIED WITH PANEL14' RJ45 CABLE (2080-9047)SUPPLIED WITH PANEL1SSP120 VOLT ACTO PRIMARYELEVATORRECALL TO ALTERNATE ELEVATOR RECALL TO ELEV LIGHT TO CONTROL SHUNT TRIP POWERSEM1-1ABOVE FACPSM1-41FL ELEVATOR LOBBY SM1-18TOP OF ELEVATORSHAFT TOSAIMM1-17PENTHOUSE ELEVLOBBYWPZZ6.8KMIDNet - M1ROOF MECH ROOMM1-25TOP OF ELEVATOR SHAFTTOSM1-26ROOF ELEV MACH ROOMM1-27R O O F E L E V M A C H R O O M M1-28R O O F E L E V M A C H R O O M M1-29ROOF ELEV MACH ROOMSM1-30ROOF ELEV MACH ROOMSM1-31ROOF ELEV MACH ROOMEMPRESS CONDO 4100es FACPStandbyTotalAlarmTotalModuleQtyDescriptionCurrentStandbyCurrentAlarmPanel Equipment4100-911114100 CONFIG. DOMESTIC 120V*0.37300.37300.47000.47004100-06343POWER DISTRIBUTION MODULE 120V0.00000.00000.00000.00004100-06362BOX TO BOX HARNESS KIT0.00000.00000.00000.00004100-06372AUDIO BOX TO BOX HARNESS KIT0.00000.00000.00000.00004100-12411MESSAGE EXPANSION BOARD - 8 MINUTES0.00200.00200.01700.01704100-12482100 WATT EXPANSION NAC BOARD0.01680.03360.06000.12004100-12491100 WATT CLASS A ADAPTER0.00100.00100.06000.06004100-12701MASTER TELEPHONE, PHONE CONTROL0.08000.08000.14000.14004100-12722EXPANSION PHONE CONTROLLER0.08000.16000.14000.28004100-1279122" BLANK DISPLAY MODULE0.00000.00000.00000.00004100-128018 SWITCH, 8 RED LED MODULE0.00000.00000.02400.02404100-1288164/64 LED/SWITCH CONTROLLER0.02000.02000.21200.21204100-13143ANALOG 100W AMP W/6 B NACS 120VAC 25V0.08500.25503.800011.40004100-23005EXPANSION BAY (PHASE 10 ONLY)0.00000.00000.00000.00004100-23203AUDIO EXPANSION BAY KIT0.00000.00000.00000.00004100-320618 RELAYS - 3 AMP0.01500.01500.19000.19004100-50057ZONE MODULE, 8 IDC, CLASS B0.07500.52500.19501.36504100-51013EXPANSION PWR SUPPLY (XPS) - 120VAC 60HZ0.05000.15000.05000.15004100-51153EXPANSION NAC MODULE - 3 NACS0.02500.07500.02500.07504100-60521EVENT REPORTING DACT0.03000.03000.04000.04004100-96201BASIC AUDIO WITH MICROPHONE - ANALOG0.25500.25500.58500.5850Panel Totals1.974615.1280IDNet Addressable Devices (SLC)4090-900114IDNET SUPERVISED IAM*Constant current draw of .8mA standby and 1mA alarm per address used.Devices requiring additional current are accounted for in the sectionlabeled "Miscellaneous Peripheral Devices Requiring Additional SystemPower".4090-90024IDNET RELAY IAM*4098-97145TRUEALARM PHOTO SMOKE SENSOR4098-97336TRUEALARM HEAT SENSOR*4098-979211TRUEALARM SENSOR BASE*Peripheral Totals0.00000.0000RUI Totals00.00000.0000Address Totals29Addresses0.02320.0290* Device Address current draw included below (See Additional Current Draws):System Totals*:Standby1.9978Alarm15.15701. 2-wire detector alarm current is included in the alarm current of the Initiating Device Circuit.2. Backup Amplifier assumes Main Amplifier alarm current on failure.StandbyStandbyAlarmAlarmBattery Set #1 (Cabinet/Charger #1)CurrentTotalCurrentTotalSelect ALL Power Supplies on this battery set:SPS-11.53603.4580XPS-10.05000.0500XPS-20.05000.0500Sub Total1.63603.5580Additional Current Draws:RUI Connected Peripheral Devices0x 0.0035= 0.0000x 0.0035= 0.0000MAPNET/IDNet Device Address Communication Current29x 0.000800= 0.0232x 0.001000= 0.0290Sub Total1.65923.5870Spare addressable point capacity0%0x 0.0008= 0.0000x 0.001= 0.0000Total1.65923.5870Standby Time =24Hrsx 1.6592= 39.8208Standby AhAlarm Time =15Min0.25 x 3.587= 0.8968Alarm Ah40.7176Additional Spare Battery Capacity =0%+0.000040.7176Battery Discharge Factor =20%+8.1435Minimum Battery Required2081-9296 50AH (2x)48.8611Battery Supplied2081-9296 50AH (2x)* System Totals represent total system current requirements. Those currents may be distributed between multiple battery sets or power supplies as shown above.StandbyStandbyAlarmAlarmBattery Set #2 (Cabinet/Charger #2)CurrentTotalCurrentTotalSelect ALL Power Supplies on this battery set:XPS-30.05000.0500Amp-10.10183.8600Amp-20.10183.8600Sub Total0.25367.7700Additional Current Draws:MAPNET/IDNet Device Address Communication Current0x 0.000800= 0.0000x 0.001000= 0.0000Sub Total0.25367.7700Spare addressable point capacity0%0x 0.0008= 0.0000x 0.001= 0.0000Total0.25367.7700Standby Time =24Hrsx 0.2536= 6.0864Standby AhAlarm Time =15Min0.25 x 7.77= 1.9425Alarm Ah8.0289Additional Spare Battery Capacity =0%+0.00008.0289Battery Discharge Factor =20%+1.6058Minimum Battery Required2081-9274 10AH (2x)9.6347Battery Supplied2081-9274 10AH (2x)StandbyStandbyAlarmAlarmBattery Set #3 (Cabinet/Charger #3)CurrentTotalCurrentTotalSelect ALL Power Supplies on this battery set:Amp-30.08503.8000Sub Total0.08503.8000Additional Current Draws:MAPNET/IDNet Device Address Communication Current0x 0.000800= 0.0000x 0.001000= 0.0000Sub Total0.08503.8000Spare addressable point capacity0%0x 0.0008= 0.0000x 0.001= 0.0000Total0.08503.8000Standby Time =24Hrsx 0.0850= 2.0400Standby AhAlarm Time =15Min0.25 x 3.8= 0.9500Alarm Ah2.9900Additional Spare Battery Capacity =0%+0.00002.9900Battery Discharge Factor =20%+0.5980Minimum Battery Required2081-9272 6.2AH (2x)3.5880Battery Supplied2081-9272 6.2AH (2x)IDNET CHANNEL M1ADDRESSES IN USE: 29 (11.6%) | SPARE ADDRESSES: 221 (88.4%) SWITCH SETTINGSAddressDevice TypePoint TypeLocation Description12345678M1-1PHOTOSMOKEABOVE FACP1-1XONM1-2SPARE1-2XONM1-3SPARE1-3XXONM1-4PHOTOSMOKE1FL ELEVATOR LOBBY1-4XONM1-5IAMHEAT2FL ELEVATOR LOBBY1-5XXONM1-6IAMHEAT3FL ELEVATOR LOBBY1-6XXONM1-7IAMHEAT4FL ELEVATOR LOBBY1-7XXXONM1-8IAMHEAT5FL ELEVATOR LOBBY1-8XONM1-9IAMHEAT6FL ELEVATOR LOBBY1-9XXONM1-10IAMHEAT7FL ELEVATOR LOBBY1-10XXONM1-11IAMHEAT8FL ELEVATOR LOBBY1-11XXXONM1-12IAMHEAT9FL ELEVATOR LOBBY1-12XXONM1-13IAMHEAT10FL ELEVATOR LOBBY1-13XXXONM1-14IAMHEAT11FL ELEVATOR LOBBY1-14XXXONM1-15IAMHEAT12FL ELEVATOR LOBBY1-15XXXXONM1-16IAMHEAT14FL ELEVATOR LOBBY1-16XONM1-17IAMHEATPENTHOUSE ELEV LOBBY1-17XXONM1-18PHOTOSMOKETOP OF ELEVATOR SHAFT1-18XXONM1-19RIAMRELAYELEV MACHINE RM1-19XXXONM1-20RIAMRELAYELEV MACHINE RM1-20XXONM1-21RIAMRELAYELEV MACHINE RM1-21XXXONM1-22RIAMRELAYELEV MACHINE RM1-22XXXONM1-23IAMHEATELEV MACHINE ROOM1-23XXXXONM1-24HEATHEATTOP OF ELEVATOR SHAFT1-24XXONM1-25HEATHEATTOP OF ELEVATOR SHAFT1-25XXXONM1-26HEATHEATROOF ELEV MACH ROOM1-26XXXONM1-27HEATHEATROOF ELEV MACH ROOM1-27XXXXONM1-28HEATHEATROOF ELEV MACH ROOM1-28XXXONM1-29HEATHEATROOF ELEV MACH ROOM1-29XXXXONM1-30PHOTOSMOKEROOF ELEV MACH ROOM1-30XXXXONM1-31PHOTOSMOKEROOF ELEV MACH ROOM1-31XXXXXONM1-32SPARE1-32XONTHRUONM1-250SPARE1-250XXXXXXONNOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES.THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS.ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING.POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES.SHEET:DRAWN BY:CHECKED BY:JOB #:PROJECT #:DESCRIPTIONCADDATEMARKSYSTEM:CHKISSUE DATE:ISSUE LOG:Revisions shown with # symbol 18" x 24" - Arch C Size 315 South 7th StreetPhone: 772 672-4636Fort Pierce, FL. 34950Fort Pierce Engineering, Inc.Dependable Mechanical, Electrical& Plumbing DesignFax: 772 672-4637C.A. No. 28173SCALE:N.T.S.RISER DIAGRAMLAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\jdirks\Johnson Controls\Project Electronics - 262-WestPalmBeach\4 Residential\Empress Condo\Elevator Upgrade\FA-201.dwg1/11/2021 11:35:43 AM JDIRKS 262:619390203SCOTT DIRKHOWARD SEVRINSKY8/20/20FIRE ALARM SYSTEMEMPRESS CONDO9600 S OCEAN DRIVEJENSEN BEACH, FL 349571830 PARK LANE SOUTH JUPITER, FL 33458 PHONE: 561-277-4140 SERVICE: 561-277-4140 FAX: 561-747-7307 DISTRICT - 262FA-201RISER DIAGRAMJOHNSON CONTROLS © 2021REV 1EMPRESS CONDOELEVATOR UPGRADE© Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.RISER NOTES:1.RISER IS A DIAGRAMMATICAL REPRESENTATION OF THESYSTEM ARCHITECTURE IN BUILDING CROSS SECTION. IT ISNOT INTENDED TO REPRESENT ACTUAL WIRE RUNS, PANELCONFIGURATIONS OR PENETRATIONS. REFER TO FLOORPLANS AND PANEL DETAILS FOR CIRCUIT ROUTING ANDCONFIGURATION INFORMATION.2.ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICALCODES. REFER TO 'APPLICABLE CODES & STANDARDS' ONSHEET FA-001 FOR SPECIFIC CODE REFERENCES.KEYED NOTES:120VAC PRIMARY POWER SOURCE SHALL BE AMECHANICALLY PROTECTED BRANCH CIRCUIT. THE CIRCUITDISCONNECTING MEANS SHALL HAVE A RED MARKING, ANDBE IDENTIFIED AS "FIRE ALARM CIRCUIT"1FIRE ALARM SYMBOL LEGENDSYMBOLDESCRIPTIONBRANDMODELBACKBOXWIRETYPEPANELS4100ES FIRE ALARM CONTROL PANEL, 120 VACSIMPLEX4100-9111SIMPLEX CABINETN/AINITIATING DEVICESADDRESSABLE STANDARD HEAT SENSOR W/REMOTE LED OUTPUT BASESIMPLEX4098-9733 HEAD4" SQ, 1-1/2" D WITH4098-9832 ADAPTER PLATEM4098-9789 BASEADDRESSABLE PHOTOELECTRIC SMOKE SENSORW/ STANDARD BASESIMPLEX4098-9714 HEAD4" SQ, 1-1/2" D WITH4098-9832 ADAPTER PLATEM4098-9792 BASEHEAT DETECTOR RATE OF RISE 135 DEGREEWEATHERPROOFTHERMOTECH302-ET1354" ROUND WP ELECTRICALBOXZMODULES AND RELAYSINDIVIDUAL ADDRESSABLE MODULESIMPLEX4090-9051SINGLE GANG 2-1/2" DW/COVERMRELAY IAMSIMPLEX4090-90024" SQ. 2-1/8" D W/ DBL.GANG COVERMRISOLATOR RELAYSPACE AGERIC-2SINGLE GANG 2-1/2" DW/COVEREND-OF-LINE RESISTOR 3.3K (EOL)SIMPLEX4081-9002END-OF-LINE RESISTOR 4.7K (EOL)4081-9003END-OF-LINE RESISTOR 6.8K (EOL)4081-9004END-OF-LINE RESISTOR 10K (EOL)4081-9008FACPZAIMWPAOM10KRSACCEPTABLECABLE TYPESFIRE ALARM WIRE LEGENDFPLR FPLP THHN TFFN OUTDOOR ** C.I.CIRCUIT DESCRIPTIONCONSTRUCTIONGAUGECIRCUIT PROPERTIESMIDNETUTP SOLID18 AWG60µF MAX TOTAL LINECAPACITANCEXXRRELAY2 COND. STRANDED14 AWGXXXXZZONE CIRCUIT2 COND. SOLID14 AWGXXXXCONDUIT SIZEMAX CONDUCTOR AREACONDUIT SIZEMAX CONDUCTOR AREA1-1/4"0.598 SQ INCH*3/4"0.213 SQ INCH*1-1/2"0.814 SQ INCH*1"0.346 SQ INCH*2"1.342 SQ INCH** 40% CONDUIT FILL PER N.E.C.STP = SHIELDED TWISTED PAIRITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEMINSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODELTHAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLEUPON REQUEST.GENERAL NOTES:1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESSNOTED OTHERWISE.2.THE DEVICE ADDRESSES INDICATED ON THESE DRAWINGS ARE ANALPHANUMERIC DESCRIPTION OF WHICH CIRCUIT THE DEVICE IS LOCATED ON.DEVICES MAY BE ASSIGNED A DIFFERENT NUMBER WITHIN THE PANEL PROGRAM.CONSULT WITH A JOHNSON CONTROLS TECHNICIAN BEFORE APPLYING APHYSICAL LABEL TO ANY DEVICES.111 1-11-2021 SCD CB CHANGES PER FIELD COMMENTS SHEET:DRAWN BY:CHECKED BY:JOB #:PROJECT #:DESCRIPTIONCADDATEMARKSYSTEM:CHKISSUE DATE:ISSUE LOG:Revisions shown with # symbol 18" x 24" - Arch C Size 315 South 7th StreetPhone: 772 672-4636Fort Pierce, FL. 34950Fort Pierce Engineering, Inc.Dependable Mechanical, Electrical& Plumbing DesignFax: 772 672-4637C.A. No. 28173LAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\jdirks\Johnson Controls\Project Electronics - 262-WestPalmBeach\4 Residential\Empress Condo\Elevator Upgrade\FA-701.dwg1/11/2021 11:35:47 AM JDIRKS 262:619390203SCOTT DIRKHOWARD SEVRINSKY8/20/20FIRE ALARM SYSTEMEMPRESS CONDO9600 S OCEAN DRIVEJENSEN BEACH, FL 349571830 PARK LANE SOUTH JUPITER, FL 33458 PHONE: 561-277-4140 SERVICE: 561-277-4140 FAX: 561-747-7307 DISTRICT - 262FA-701WIRING TYPICALSJOHNSON CONTROLS © 2021REV 1EMPRESS CONDOELEVATOR UPGRADE© Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.CLASS B WIRING(-)ADDRESSABLE RELAY MODULESERIESCONNECTIONIDNet SLC(+)IDNet SLCTERMINATION VIEWN.C.MOUNTING OPTION "A"4"(102mm) SQUARE BOX4090-9002 RELAY IAMCOVER PLATESIMPLEX 4090-90021.MAINTAIN CORRECT POLARITY ON TERMINALCONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECURE UNDERTERMINALS. NEVER LOOP WIRES UNDERTERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJAPPROVED METHODS.WIRING NOTES(-)(-)OPTIONAL TAPLOCATIONFOR IDNet SLCT-TAP (SPLICE)CONNECTION12345678123456781234567812345678CN.O.1.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4090-0002 FROM HTTP://WWW.SIMPLEX-FIRE.COM(+)(+)TO CONTROLLEDDEVICE. SEE DATASHEET FOR POWERRATING LIMITATIONS.MOUNTING OPTIONSOPTION 1DESCRIPTIONNOTEA4" (102mm) SQUARE BOX, 2-1/8" MINIMUM DEPTH WITH DOUBLE GANG COVER PLATEBY OTHERSB4" (102mm) SQUARE BOX, 2-1/8" MINIMUM DEPTH WITH SIMPLEX 4090-9801 TRIM PLATEFOR SEMI-FLUSH MOUNTED BOXBOX BY OTHERS, PLATES ORDEREDSEPARATELYC4" (102mm) SQUARE BOX, 2-1/8" MINIMUM DEPTH WITH SIMPLEX 4090-9802 TRIM PLATEFOR SURFACE MOUNTED BOXBOX BY OTHERS, PLATES ORDEREDSEPARATELYDEVICE MOUNTING HEIGHT REFERENCEPER NFPA 72SIDE WALLCEILINGVISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS1.MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO TOPOF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW2.177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24"(610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER INTENSITY ISTO COMPENSATE FOR A POSSIBLE SMOKE LAYER.AUDIBLE ONLYAUDIBLE/VISUAL& VISUAL ONLYAPPLIANCESSYNCHRONIZE MORETHAN TWO APPLIANCESIN ANY FIELD OF VIEW.NOTE: REFER TO THE PROPER DEVICEINSTALLATION INSTRUCTIONSFOR BACKBOX MOUNTING HEIGHT.NOTE: MEASUREMENTSSHOWN ARE TO THE CLOSESTEDGE OF THE DETECTOR.THE 4" REQUIREMENT FOR SMOKE DETECTORS HASBEEN REMOVED FROM THE 2010 EDITION OF NFPA 72CEILING MOUNTEDSMOKE/HEATDETECTORACCEPTED HEREHEAT DETECTORSNEVER HEREWALL MOUNTEDSMOKE/HEAT DETECTOR4"(102mm)4"(102mm)3' (914mm)MINIMUMA/C SUPPLYOR RETURNDIFFUSERFINISHEDFLOORFIREMAGNETICDOORHOLDERFIREPHONEJACKFOR CEILING HEIGHTS LESS THAN 86"(2180mm), THE VISUAL LENS MOUNTING HEIGHTSHALL BE WITHIN 6" (150mm) OF THE CEILING.96" MAX (ADA, IBC, NFPA)(2440mm MAX)ABOVE FINISHED FLOORTO TOP OF LENS48" MAX (ADA) (1219mm)48" MAX (NFPA, ADA) (1219mm MAX)42" MIN (NFPA) (1067mm MIN)MEASUREMENTS SHOWN ARETO TOP OF PULL HANDLEMANUAL PULLSTATIONTO EXIT DOOR5' (MAX.)(1524mm)DOORWIDTHLESS 3"(76mm)5"(127mm)90" MIN (2286mm MIN)ABOVE FINISHED FLOOR(OTHER MOUNTING HEIGHTS SHALL BEPERMITTED BY THE AHJ PROVIDING IT MEETSTHE SOUND LEVEL OUTPUT REQUIRED.)NFPA 72 AUDIBLE APPLIANCE 6" MIN(152.4mm MIN) BELOW FINISHED CEILINGFIREFINISHEDWALL12" (305mm)MAXIMUM TO TOP OF SENSOR80" MIN (ADA, IBC, NFPA)(2032mm MIN)ABOVE FINISHED FLOORTO BOTTOM OF LENSWIRING NOTESSERIESCONNECTIONTERMINATION VIEW: DEVICE REAR733-896(4.7K 1/2W)ELECTRICAL BOXCOVERPLATEYELREDGRAYYELBLKRED(-)ADDRESSABLE INPUT MODULESIMPLEX 4090-9051 (IAM)CLASS B WIRING1.MAINTAIN CORRECT POLARITY ON TERMINALCONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECURE UNDERTERMINALS. NEVER LOOP WIRES UNDERTERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTED ANDAHJ APPROVED METHODS.1.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4090-0001 FROM HTTP://WWW.SIMPLEX-FIRE.COMIDNet SLC(+)(-)T-TAP (SPLICE)CONNECTION733-984(1.8K 1/2W)MOUNTING OPTION "A"4090-9051 IAMGRAYBLK733-886(6.8K 1/2W)(+)OPTIONAL TAPLOCATION FOR IDNetSLCIDNet SLC(+)(-)MOUNTING OPTIONSOPTION 1DESCRIPTIONNOTEASINGLE GANG BOX, 2-1/2" (64mm) DEEP WITH SINGLE GANG COVER PLATEBY OTHERSB4" SQUARE BOX, 2-1/2" (64mm) DEEP WITH COVER PLATEBY OTHERSC4" OCTAGONAL BOX, 2-1/2" (64mm) DEEP WITH COVER PLATEBY OTHERSCLASS B WIRINGSENSOR BASE WITH REMOTE LED CONNECTION1.MAINTAIN CORRECT POLARITY ONTERMINAL CONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECUREUNDER TERMINALS. NEVER LOOP WIRESUNDER TERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTEDAND AHJ APPROVED METHODS.4.100 FT. MAXIMUM WIRE DISTANCE FROMTHE 4098-9780 BASE TO THE RELAY.WIRING NOTESIDNetSLC(-)(+)(-)(+)(-)(+)OPTIONAL TAP LOCATIONFOR IDNet SLCT-TAP (SPLICE)CONNECTIONSERIESCONNECTIONIDNetSLCTERMINATION VIEW: DEVICE REARREMOTE LED(-)(+)TO RELAY(-)(+)3' (941mm)MIN.4" (102mm)CEILING MOUNTED SENSORHEAT SENSORS NEVER HERE12"(305mm)MAXIMUMTO TOP OFSENSORFINISHED WALLWALL MOUNTED SENSORSIMPLEX 4098-97891.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4098-0019 FROM HTTP://WWW.SIMPLEX-FIRE.COMSENSORMOUNTING OPTION "A"BASEELECTRICAL BOX#6-32 SCREWWITH WASHER(NOT SUPPLIED)#8-32 x 1-1/4" PANHEADMACHINE SCREW(TIGHTEN TO 4-6 in.-lbs.)MOUNTING OPTION "B"MOUNTING OPTIONSOPTION 1DESCRIPTIONNOTEASINGLE GANG BOX, 2-1/8" (54mm) DEEP - FLUSH MOUNTBY OTHERSB4" (102mm) OCTAGONAL BOX, 1-1/2" (38mm) DEEP, MINIMUM - FLUSH MOUNTBY OTHERSC4" (102mm) SQUARE BOX, 1-1/2" DEEP (MIN) W/ SIMPLEX 4098-9832ADAPTER KITBOX BY OTHERS, 4098-9832 ORDEREDSEPARATELYD4" (102mm) SQUARE BOX, 1-1/2" DEEP (MIN)W/ SINGLE GANG COVER PLATE 3/4" (19mm) EXTENSIONBY OTHERS0=OFF1=ON2412422442452432402472482502512492532542552522461931941961971952092102112122131922081451461481491471611621631641651441601761771781791801811992002022032012152162172182192052062072212222232042201511521541551531671681691701711571581591731741751561721831841851861871881891901911501661821982142242252262272282292302312322332342352362372382391286432786842423516ADDRESS SHOWN ABOVE IS 1201ON1OFF1291301321331319798100101991131141151161179611212881828485834950525351656667686948648013513613913813710310410610710511912012112212314214114310911011112512612710812414087889190895556585957717273747594939561626377787960769254708610211813433343637351245317181920210163239404342417810119232425262746454713141529303112284462238DIP SWITCHES 5 THRU 8DO NOT USE ADDRESS 0 FOR AN IDNET ADDRESS9NOTE:THE 4098-9771, -9794, -9795, -9798 SOUNDER BASES HAVE A 9-POSITION DIP SWITCH. THE FIRST EIGHT DIP SWITCHES SET THESOUNDER BASE ADDRESS. DIP SWITCH POSITION 9 IS SET TO OFF OR ON DEPENDING UPON THE SOUNDER BASE POWERSOURCE. WHEN THE SOUNDER BASE IS CONNECTED TO A 24 VDC POWER SOURCE, DIP SWITCH POSITION 9 IS SET TO “OFF”AND THE 24 VDC POWER IS SUPERVISED BY THE SOUNDER BASE. WHEN THE SOUNDER BASE IS POWERED BY THE PANEL’SNOTIFICATION APPLIANCE CIRCUIT (NAC), DIP SWITCH POSITION 9 IS SET TO “ON” AND THE POWER IS SUPERVISED BY THENAC AND NOT THE SOUNDER BASE. THE 4098-9770 AND -9797 BASES HAVE THE SAME LAYOUT, BUT DOESN’T OFFERSOUNDER FUNCTIONALITY. THEY USE AN 8-WAY DIP SWITCH ONLY.SEENOTEDIPSWITCHES1 THRU 4DIP SWITCH SETTINGS - INITIATINGSIMPLEX IDNet1.MAINTAIN CORRECTPOLARITY ON ALLCONNECTIONS.2.USE ONLY AHJ APPROVEDWIRE SPLICE METHOD.WIRING NOTES1.FOR ADDITIONAL INFORMATION, REFER TO MANUFACTURER DATA SHEET.(-)(+)TO ADDITIONAL INITIATING DEVICES OR RETURN TOFIRE ALARM CONTROL PANEL FOR CLASS AAPPLICATION.IF LAST INITIATING DEVICE ON CIRCUIT IN A CLASS BAPPLICATION CONNECT AN END-OF-LINE RESISTORWITH A VALUE DEPENDENT ON THE MONITORINGDEVICE.FROM FIRE ALARMCONTROL PANELOR PREVIOUSINITIATING DEVICECONVENTIONAL HEAT DETECTORSIMPLEX 2098-9490 & 2098-9891 (THERMOTECH 302-ET)MOUNTING OPTIONSOPTION1DESCRIPTIONNOTEA3-1/2" OR 4" OCTAGONAL BOX, 1-1/2" DEEP WITH AP-P ADAPTER PLATESUPPLIED BY ELECTRICAL CONTRACTORHEAT SENSOR(+)(-)FINE SILVER CONTACT POINTSEXPANSION STRUTSHIGH EXPANSION SENSINGSHELL 0.040 ANODIZEDHEAT CONTROL SLEEVESETTING SCREWDEVCON HERMETIC SEAL4" OCTAGONAL BOX 1 1/2"DEEPSUPPLIED BY CONTRACTORELECTRICAL BOX3 1/2" OCTAGONAL,SUPPLIED BY CONTRACTORTHREADED HUB COVER1/2" CONDUIT THREAD(HAND TIGHTEN ONLY)1 1-11-2021 SCD CB CHANGES PER FIELD COMMENTS CLASS B WIRING1.MAINTAIN CORRECT POLARITY ONTERMINAL CONNECTIONS.2.ALWAYS CUT CONDUCTORS AND SECUREUNDER TERMINALS. NEVER LOOP WIRESUNDER TERMINALS.3.ANY WIRE SPLICES TO BE MADE BY LISTEDAND AHJ APPROVED METHODS.WIRING NOTESIDNetSLC(-)(+)(-)(+)STANDARD SENSOR BASE(-)(+)OPTIONAL TAPLOCATIONFOR IDNet SLCT-TAP (SPLICE)CONNECTIONSERIESCONNECTIONIDNet SLCTERMINATION VIEW: DEVICE REAR3' (941mm)MIN.4" (102mm)CEILING MOUNTED SENSORHEAT SENSORS NEVER HERE12"(305mm)MAXIMUMTO TOP OFSENSORFINISHED WALLWALL MOUNTED SENSORSIMPLEX 4098-97921.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4098-0019 FROM HTTP://WWW.SIMPLEX-FIRE.COMMOUNTING OPTIONSOPTION 1DESCRIPTIONNOTEASINGLE GANG BOX, 2-1/8" (54mm) DEEP - FLUSH MOUNTBY OTHERSB4" (102mm) OCTAGONAL BOX, 1-1/2" (38mm) DEEP, MINIMUM - FLUSH MOUNTBY OTHERSC4" (102mm) SQUARE BOX, 1-1/2" DEEP (MIN) W/ SIMPLEX 4098-9832ADAPTER KITBOX BY OTHERS, 4098-9832 ORDEREDSEPARATELYD4" (102mm) SQUARE BOX, 1-1/2" DEEP (MIN)W/ SINGLE GANG COVER PLATE 3/4" (19mm) EXTENSIONBY OTHERSMOUNTING OPTION "C"MOUNTING OPTION "D"SENSORBASEELECTRICAL BOX#8x1" THREAD FORMINGPANHEAD SCREW(TIGHTEN TO 4-6 in.-lbs.)#6-32 x 1-1/4"PANHEAD SCREW(TIGHTEN TO 4-6 in.-lbs.)4098-9832ADAPTERPLATE KITADAPTERBRACKET8-32 x 1-1/4"PANHEAD MACHINESCREW (TIGHTENTO 1-3 in.-lbs.)1