Loading...
HomeMy WebLinkAboutCompaction TestUES Project No: Workorder No: Report Date: 3330.1700113.0000 221441-1 01/13/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:GHO HOMES CORPORATION UES Technician:Mark Rogers 590 NW Mercantile Place Port St. Lucie, FL 34986 Date Tested:12/31/2021 Project:17-6977 GHO SCATTERED LOTS- PORT ST. LUCI GFA Proposal #17-6977.00 terrik@ghohomes.com, workdone@ghohomes.com, County, Type of Test: Area Tested:2646 Conifer Drive, Lot 63, Fort Piece Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Northeast corner of lot 0-1 ft 103.8 12.5 101.3 12.2 98 Pass 2 Southwest corner of lot 103.8 12.5 100.8 12.1 97 Pass 3 Center of lot 0-1 ft 0-1 ft 103.8 12.5 101.9 12.2 98 Pass Remarks:Above stripped surface 1-2, 2-3’ HCP=60+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. Reviewed By GFA International, Inc Certificate of Authorization No. 4930 John Kent Senior Project Engineer STATE OF FLORIDA Professional Engineer No. 63218 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1