Loading...
HomeMy WebLinkAboutProduct Approval; Metal RoofingEY-A.I. uAnwN REPORT OF AMTAL S>, :,ES 11A �C']C , Rd 'GORATION' FLORIDA BUILDING CODE 6TO JOITION (2011) FLORIODA .PRWCT APPROM— FL ,14645.112-R3 cs R �,. �0 T Prepared For: Metalsales M-anufaeturinng Corporatid.n 545 South 3rd Street, Suite 1'00. Looi ville,1KY :40202 'I['elpp one (502) 855-4300 Fax: (502) 855.4200 Prepared B : Bala Sockalingam, Ph.D., P.E. IFloa nda Professional Engineer #6.22:4.0 1216 N Lansing Ave:; Suite-C Tulsa, ok 74106 Telephon.o: (918) 492-5992 FAX: (866)- 3664543 RECEIVED NOV 1. 9.. ;1010 Permitting Department St. Lucie County T.his.repori consists of Evaluataorn .Report (3 Pages including cover) ��0q�s�>ltanirpsagy�4 Installation Details (1 Page). �®%��P SQC�!�C/�V' '�-io� I,oad'Span Table ( Page) ��a ��,•�� E N° fi•a, 9,�� Report Nm. C2182-12. bate: 9.937 No 62240 w a STAT E. 0 r 44 �' �{, v® •••'•• MOO- 0 o _ . C� :'26 C7 FL 14645.12-R3 C2182-12 9.9.17 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Image II Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 7/16" thick OSB or min. 15/32" thick Plywood or min. W thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Allowable Uplift Load: 20.8 psf @ fastener spacing of 24" o.c (Factor of Safety = 2) 63.5 psf @ fastener spacing of 6" o.c 86.55 psf @ fastener spacing of 6" o.c with 3/8" bead adhesive in panel sidelap Fastener Pattern: #10 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of/4". Sidelap Adhesive: Schnee -Morehead SM7108 Permathane adhesive Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) `Uplift Resistance of Roof Assemblies' & UL1897-98 `Uplift Tests for Roof Covering Systems'. Test Equivalency: The test procedures in UL 580-94 comply with test procedures prescribed in UL 580-06. The test procedures in UL 1897-98 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4 FL 14645.12-R3 C2182-12 9.9.17 Page 3 of 3 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580/UL1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T176-11, Reporting Date 4/26/11 Project No. T260-11, Reporting Date 8/15/11 ROOF PANEL ROOF PANEL EXISTING SHINGLES SEE DETAIL 1 (OPTIONAL) _ / MIN. 2X_ WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. NEW UNDERLAYMENT - (REQUIRED ONLY FOR NEW CONSTRUCTION) MAX. 16" �- MINIMUM ATTACHMENT: EXISTING UNDERLAYMENT 8d x 2.5" LONG RING SHANK NAIL (OPTIONAL) OR #8 x 2" LONG WOOD SCREWS SPACED m 6" O.C. IN THE FIELD & AT EDGES FASTENING PATTERN 1 EXISTING SHINGLES NEW UNDERLAYMENT SEE DETAIL 2 (OPTIONAL) (REQUIRED ONLY FOR ADHESIVE IN THE / n \ NEW CONSTRUCTION) -� PANEL SIDELAP EXISTING UNDERLAYMENT LN�MINIMUM ATTACHMENT: (OPTIONAL) 8d x 2.5" LONG RING SHANK NAIL MIN. 2X_ WOOD RAFTER/JOIST/ OR #8 x 2" LONG WOOD SCREWS TRUSS AT MAX. 24" O.C. SPACED ® 6" O.C. IN THE FIELD & AT EDGES FASTENING PATTERN 2 NEW UNDERLAYMENT TYPICAL PANEL INSTALLATION X—SECTION (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES #10 PANCAKE SCREW (OPTIONAL) @ MAX. 24" O.C. PANEL MIN 26 GA. DETAIL 1 EXISTING UNDERLAYMENT - (OPTIONAL) NEW UNDERLAYMENT - (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) DETAIL 2 EXISTING UNDERLAYMENT (OPTIONAL) - OSB 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) SIDELAP ADHESIVE NOM. 3/8" BEAD #10 PANCAKE SCREW ® MAX. 6" O.C. PANEL /—MIN 26 GA. OSB 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) i n- SiDELAP ADHESIVE LOCATION PANEL FASTENER SPACING PER UPLIFT LOAD TABLE. \—OSB 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) PANEL FASTENER SPACING PER ALLOWABLE PRESSURE TABLE. \—OSB 7/16 THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA (t = 0.018'. MAx, EFFECTIVE COVERING WIDTH OF PANEL = 16". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING do STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE. THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSISIUTY OF OTHERS. D- IX o U ON 0 �N Z O "t O Q 0- Yh LL I z o u' Q OfLd J DD 1J I cn _� N J Aso No Lno m w CL J � w W 0 OL a m w Q 0 Z ux� Us .aFiN m �s sc a II 1 OF 1 II METAL SALES MANUFACTURING CORPOIRATION, Image IM, pfift Loads (M, n. 26 ga.) DescriptionFastener S 1. pacing I along Panel Length Allow -able Uplift Load Coverage width: 1611 Panel Fastener, #I O= 12 pancake. head screws 6 615 8 58. ... ....... ..... . 10 . .. ..... . . . . ....... 12 . ..... .. 49.8 41.5 .... . ....... . . 35.6 31,J 14 16 IS ------20 22 24 22..6 . . . .. ..... .......... 20,8 With Sidelap an Sealant I 6 - 86.55 Notes: 1. The bold numbers indicate dosign.loadsQ.alculated from test data with safetyfactor of 2. 2. Panels niust be installed as per Evaluation Report FL 14645.12 and Metal Sales euttefit installationprocedure. 3. Three or more, span .5 condition. E 1q. 0 No 62240 S TAT E 0 F 014U 4F 0 R 1 1216 N Lansing Ave,, Suite C Tulsa,.Ok 74106 918 492 5992 .Bala Sockalingam, Ph.D., P.E. FL 62240