NCI Group Inc.
14031 West Hardy
Houston,TX.77060
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 5V Crimp Panel
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable Building Code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA 911-0810.10 and consists of pages 1 through 7.
The submitted documentation was reviewed by Gaspar J Rodriguez.
REVIEWED FOR
S+
CODE COMPLIANCE NOA No.: 15-0629.04
M{AMNDADE COUNTY Expiration Date: 02/26/21
i
ST. LU C 0 E COUNTY Approval Date: 10/22/15
BOCC f� / Page 1 of 7
r
ROOFING ASSEMBLY APPROVAL:
Category: Roofing
Sub-Category: Non-Structural Metal Roofing
Materials: Steel
Fire Classification: See General Limitations#1
Maximum Design Pressure: -146 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Specifications Product Description
5V Crimp Roof Panel Length :various TAS 125 Corrosion resistant,
Width:26 1/8" galvalume,performed,
(Coverage width : 24") standing seam,coated,pre-
Thickness : 0.0217 finished,metal panels.
MANUFACTURING LOCATION:
1. Houston,TX
2. Adel,GA
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Farabaugh Engineering and T139-08 TAS-100 03/13/08
Testing,Inc.
Force Engineering& 07-293T-06A-C TAS-125 01/16/06
Testing,Inc.
Underwriters Laboratories, File R8116 Standard Requirements for Metal 06/97
Inc. Project 97RT4520 Roofing Systems
Miami-Dade County TAS-125
Center for Applied MTS Job No.257829 Wind Driven Rain 10/96
Engineering, Inc. Miami-Dade County TAS-100
Underwriters Laboratories, File R11609 UL 580 02/02
Inc. Project OIRT10456 TAS-125
PRI Asphalt Technologies, MBC-003-02-01 Wind Driven Rain 11/01
Inc. TAS 100
NOA No.: 15-0629.04
MIAMMADE COUNTY Expiration Date: 02/26/21
Approval Date: 10/22/15
Page 2 of 7
SYSTEM DESCRIPTION
SYSTEM A-1: 115V-Crimp"26 Ga.Metal Panel
Deck Type: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank.
Slope Range: 2":12" or greater
Maximum Uplift The maximum allowable design pressure for the 24"wide panel shall be
Pressure: —90 psf.(See General Limitation#2)
Deck Attachment: In accordance with applicable Building Code,but in no case it shall be less than
#6 x 2"screws or 8d common annular ring shank nails spaced at 6"o. c. In re-
roofing,where deck is less than 19/32"thick(minimum 15/32")the above
attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be a ASTM D 226 Type II installed with a
minimum 4"side-laps and 6"end-laps. Underlayment shall be fastened with
corrosion resistant tin-caps and 1'/4"annular ring-shank nails,spaced 6"o.c. at all
laps and two staggered rows 12"o.c. in the field of the roll.
Valleys: Valley construction shall be in compliance with Roofing Application Standard
RAS 133 and with NCI Group's current published installation instructions.
Fire Barrier Any approved fire barrier having a current NOA. Refer to a current fire directory
Board: listing for fire ratings of this roofing system assembly as well as the location of
the fire barrier within the assembly. See Limitation# 1.
Metal Panels and Install the "5V-Crimp Panels" including flashing penetrations, valleys, and
Accessories: accessories in compliance with NCI Group's current published installation
instructions and in compliance with the minimum requirements detailed in
Roofing Application Standard RAS 133.
NCI Group "5V-Crimp Panels" shall be installed with a minimum #14 corrosion
resistant fasteners with sealing washers of sufficient length to penetrate
5/16"through the sheathing. Fasteners shall be spaced in accordance with fastener
detail herein as follows:
1. Panel side ribs shall be fastened along side of the panel inside ribs,one
fastener at the overlap and one fastener at the underlap. Center panel rib
shall be fastened with two fasteners at the each side of center panel.
2. All fasteners at center rib,underlap rib, and overlap rib shall be spaced
at a maximum of 36 inches o.c.parallel to the roof slope. See Detail A
herein.
NOA No.: 15-0629.04
MIAM4DADECOUNW Expiration Date: 02/26/21
Approval Date: 10/22/15
Page 3 of 7
5V CRIMP PANEL
DETAIL A
12" 0.5"
24"COVERAGE
PANEL OVERLAP FASTENER w/WASHER
- - - - - - - - - - - -- --- - - - - - - - - ---- - - --- - ---- - - - - ---
- ----- - - - - --- - - - - --
SUBSTRATE PANEL UNDERLAP
FASTENING PATTERN AT FIELD, EAVE & RIDGE OF PANEL
Fastener w/Washer
Spaced at 36" o.c.
5V Panel
NOA No.: 15-0629.04
MAMMADE COUNTY Expiration Date:02/26/21
VVYWITIA1 Approval Date: 10/22/15
Page 4 of 7
SYSTEM A-2: 115V-Crimp"26 Ga.Metal Panel
Deck Type: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank.
Slope Range: 2":12" or greater
Maximum Uplift
Pressure: See Table B Below. (See General Limitation#2)
Deck Attachment: In accordance with applicable Building Code,but in no case it shall be less than #6 x
2"screws or 8d common annular ring shank nails spaced at 6"o. c. In re-roofing,where
deck is less than 19/32"thick(minimum 15/32")the above attachment method must be in
addition to existing attachment.
Underlayment: Minimum underlayment shall be a ASTM D 226 Type 11 installed with a minimum 4"
side-laps and 6"end-laps. Underlayment shall be fastened with corrosion resistant tin-
caps and 1'/4"annular ring-shank nails,spaced 6"o.c.at all laps and two staggered rows
12"o.c. in the field of the roll.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with NCI Group current published installation instructions.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing
for fire ratings of this roofing system assembly as well as the location of the fire barrier
within the assembly. See Limitation# 1.
Metal Panels and Install the "5V-Crimp Panels" including flashings penetrations, valleys, and accessories
Accessories: in compliance NCI Group's current published installation instructions and in compliance
with the minimum requirements detailed in Roofing Application Standard RAS 133.
NCI Group "5V-Crimp Panels" shall be installed with a minimum#10-15 corrosion
resistant fasteners with sealing washers of sufficient length to penetrate 3/16"through the
sheathing. Fastener shall be spaced at a maximum of 12"o.c.perpendicular to the slope,
in rows spaced as noted below in Table B running parallel to the slope of the roof.
Fastener shall be placed at high points of panel ribs. See Detail B herein.
TABLE B
MAXIMUM DESIGN PRESSURES
Roof Areas Field Perimeter and Corners
Maximum Design Pressures —74.75 PSF —146 PSF
Maximum Fastener Spacing 24" OC 12" OC
1. Extrapolation shall not be allowed
NOA No.: 15-0629.04
MIAMI•DADECOUNTY Expiration Date: 02/26/21
Approval Date:10/22/15
Page 5 of 7
5V CRIMP PANEL
DETAIL B
12" 05.
24 COVERAGE
PANEL OVERLAP FASTENER w/WASHER
SUBSTRATE PANEL UNDERLAP
FASTENING PATTERN AT FIELD, EAVE & RIDGE OF PANEL
#10-15 Fastener w/Washer
spaced as noted in Table B.
5V Panel astener Spacing
as perTable B
Spacing as per
Table B
NOA No.: 15-0629.04
MLAMMADe COUNW Expiration Date: 02/26/21
Approval Date: 10/22/15
Page 6 of 7
LIMITATIONS
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e.field,
perimeters,and corners). Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening
at enhanced pressure zones(i.e.perimeters, extended corners and corners).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133
4. All panels shall be permanently labeled with the manufacturer's name and/or logo,and the following statement:
"Miami-Dade County Product Control Approved" or with the Miami-Dade County Product Control Seal as
seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo,and/or model.
MMMI-DADE COUNTY
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE