Loading...
HomeMy WebLinkAbout2003-21_OaksIndian River 12 _SPRev_01-12-21Sig2SURVEYOR'S REPORT 1 This Survey shall not be valid unless sealed with an embossed Surveyor's Seal 2 No underground improvements have been located as part of this Survey. 3 The last field date of this Survey was: 4-18-19. 4 This Survey was prepared using the Plat of Record only. No other documents were provided and no search of the public records was performed by this office. 5 This Survey was prepared in accordance with the Standards for the practice of Surveying & Mapping as defined in 5J-17.050-052FAC. 6 By acceptance of this survey all parties agree that the signing surveyor's liability is limited to the amount paid for said Survey. 7 Unless other wise noted all bearing and distances are in accordance with the record plat and have been verified by field measurements. See map for bearing base. 8 Parcel/Lot line locations have been based on found survey control along the South Right of Way line of Eden Creek Lane. 9 LEFT BLANK. 10 The Legal Description shown hereon was provided by the client and/or his/her representatives. 11 No ownership of fence lines has been determined as part of this Survey. 12 Off set calls to found survey control are relative to the nearest property corner, intersection of lines, point of curvatures (PC), point of reverse curvatures (PRC) or other identifiable point. 13 Compliance with local zoning requirements and or with requirements set forth by other State, Public, and/or Private entities has not been verified as part of this Survey. 14 There is no platted Easement adjacent to the Right of Way, Therefore it appears that there is an apparent use of the property by the Florida Power & Light Co, Pad as shown hereon. 15 Elevations shown hereon (0.00) are in accordance with the north American Vertical Datum of 1988. LEGEND C — Concrete CIE — Covered Entry CAC — Concrete Pad with Air Conditioning CB — Catch Basin CBS — Concrete Block Structure CUP — Corrugated Metal Pipe CPE — Concrete Pad with Pool Equipment CTV — Cable TV Box FFE — Finished Floor Elevation GV — Water Gate Valve HYD — Fire Hydrant OIL — Overhead Utility Line PP — Power Pole SSMH — Sanitary Sewer Manhole TCB — Telephone Communications Box UB — Utility Box WM —Water Meter X00.00 - existing Elevations. El. - Elevation FFE - Finished Floor Elevation 00.00 - Proposed Finished Grade FEMA Flood Zone data shown here on is based on the visual inspection of the digital Flood Hazardous Maps provided by the Federal Emergency Management Agency (FEMA) and is limited to the accuracy of such maps. Flood Zone: X Community #: 120285, Panel #:313, Suffix: K, Date: 2.19.2020 Mr. Young and Ms. Barry LEGEND FCM — Found 4"x4"Concrete Monument FIP — Found }" Iron Pipe FIPC — Found Iron Pipe with Cap FIR — Found 15 Iron Rod FIRC — Found 15 Iron Rod with Cap SIRC — Set 15 Iron Rod with Cap "LB17357" FIPC — Found 112" Iron Pipe with Cap FM — Found Mag Nail FMD — Found Mag Nail with Disk FN — Found Nail FNTT — Found Nail with Tin Tab FPK — Found PK Nail FPKD — Found PK Nail with Disk FRRS — Found Rail Road Spike /CO — In Pavement Cut Out Prepared By: Regina C. Kamer, PSM#4363 Kamer Surveying, Inc. LB#7357 °p I FND#5 RC 4049 X0.33'E o LEGAL DESCRIPTION Lot 12, OAKS AT INDIAN RIVER, according to the Plat thereof, as recorded in Plat Book 33, page(s) 10 and 10A, Public Records pf St Lucie County, Florida. VACANT \ \ 6"Deep Detention Swale / Lot 11 0„ w 187.58' (P) \ �`� 552.501 h N53 0656"E 187.89' (M) \ I 1 —4�12 �7g160 d m —� — -----95.20'------- °I I Lot 12 One Story Re,'k" Lane En121 Eden Creek m o� °I 7 o I �33 1n \ ° C \10 �7S36I \\ \\ N �7Q 30 --— u7 \ Water L1ner L0 ell proposed W 14.25-1 �7S z� ---- 14.32 �. `S8`9 09 �s FND#5 S89 g �S� C 4049 7g 06 os, 66 r-J %J \ Prepared For: Mr. Young & Ms. Barry 15 t Lot used Concrete Drive \ Prop � w •� - 1g.3 3 Garage El' 15 67 e i ResidencFloor t 16.0 e Story FinlshednatelY Height .O PEos r ,eld lepat d toApprd 0 F \a sublet 1.00 16.68 C' Wit° 729 0 7 co o/ II • 33"E 194 g5 (M�(P) 00 N45 06 - l a w/ VACANT Lot 13 , �73 96 I I 77 I FND - PCP LS1272 N, W \ Q0 rn, / PGP \ Fop 512�2 ��,� g03o0, R'1.06 30 �D�1 56 5 N35.9 PG \ L--68•17' / \ R=50.0011 ' 1 6=78'07' 14 \ FN 5 RC D 049 Ga?®5 `3 7Q T l 0-� I t0,ry � �r•`33 17 \ -t \ 0 n \ _n CD 0 U) \ 6— n (°• I d ao T, \ % I n \ � I I \ \ I \ J / g.00 \ Tan; w 12.67 5.5 FC D40 cw o �50 5.5 0 �722' -�-77 . SO A-77 . 6S A 70 . 90 1 I �6 P' s) co 10.16' �` o o d flco �o t00 FND — PCP 72 ,0 A u, \ o LS 12 O O. O L Center Line o F� �� L=197.41' i oo' /o Cl�„�7) OO 6 22 �12'42>, ��pp 0- ` cm`Y�p � L=98.70' ,� \ 7�9 R=50 00' 7 0A=113.06'09" o / ti Sao ------------- Co 77 OOS( Ch c" I o I I b I 7�90 90 I I I I I I I I I I I KARNER SURVEYING, INC. Rp ryg i n a Dig t "signed by Regina Residential & Commercial Surveying Services i< rller Ka Darner, PSM 2021.01.L2 2740 SW Martin Downs Blvd.#333, Palm City, F1.34990 , �$M 13:13:19-05'00' Phone: (772)288 7206 Fax:(772)223 8181 `-- VWW.KARNERSURVEYINGINC.COM learner®comcost.net A2ErVeb .dS,� y- sea Date: 1.9.2021 Revision 11-1pt/on, Site Plan 1.12.2021 Add Water Line