HomeMy WebLinkAbout2003-21_OaksIndian River 12 _SPRev_01-12-21Sig2SURVEYOR'S REPORT
1 This Survey shall not be valid unless sealed with an embossed Surveyor's Seal
2 No underground improvements have been located as part of this Survey.
3 The last field date of this Survey was: 4-18-19.
4 This Survey was prepared using the Plat of Record only. No other documents were
provided and no search of the public records was performed by this office.
5 This Survey was prepared in accordance with the Standards for the practice of
Surveying & Mapping as defined in 5J-17.050-052FAC.
6 By acceptance of this survey all parties agree that the signing surveyor's liability is
limited to the amount paid for said Survey.
7 Unless other wise noted all bearing and distances are in accordance with the record
plat and have been verified by field measurements. See map for bearing base.
8 Parcel/Lot line locations have been based on found survey control along the South
Right of Way line of Eden Creek Lane.
9 LEFT BLANK.
10 The Legal Description shown hereon was provided by the client and/or his/her
representatives.
11 No ownership of fence lines has been determined as part of this Survey.
12 Off set calls to found survey control are relative to the nearest property corner,
intersection of lines, point of curvatures (PC), point of reverse curvatures (PRC) or
other identifiable point.
13 Compliance with local zoning requirements and or with requirements set forth by
other State, Public, and/or Private entities has not been verified as part of this Survey.
14 There is no platted Easement adjacent to the Right of Way, Therefore it appears
that there is an apparent use of the property by the Florida Power & Light Co, Pad as
shown hereon.
15 Elevations shown hereon (0.00) are in accordance with the north American Vertical
Datum of 1988.
LEGEND
C — Concrete
CIE — Covered Entry
CAC — Concrete Pad with Air Conditioning
CB — Catch Basin
CBS — Concrete Block Structure
CUP — Corrugated Metal Pipe
CPE — Concrete Pad with Pool Equipment
CTV — Cable TV Box
FFE — Finished Floor Elevation
GV — Water Gate Valve
HYD — Fire Hydrant
OIL — Overhead Utility Line
PP — Power Pole
SSMH — Sanitary Sewer Manhole
TCB — Telephone Communications Box
UB — Utility Box
WM —Water Meter
X00.00 - existing Elevations.
El. - Elevation
FFE - Finished Floor Elevation
00.00 - Proposed Finished Grade
FEMA Flood Zone data shown here on
is based on the visual inspection of
the digital Flood Hazardous Maps
provided by the Federal Emergency
Management Agency (FEMA) and is
limited to the accuracy of such maps.
Flood Zone: X Community #: 120285,
Panel #:313, Suffix: K, Date: 2.19.2020
Mr. Young and Ms. Barry
LEGEND
FCM — Found 4"x4"Concrete Monument
FIP — Found }" Iron Pipe
FIPC — Found Iron Pipe with Cap
FIR — Found 15 Iron Rod
FIRC — Found 15 Iron Rod with Cap
SIRC — Set 15 Iron Rod with Cap "LB17357"
FIPC — Found 112" Iron Pipe with Cap
FM — Found Mag Nail
FMD — Found Mag Nail with Disk
FN — Found Nail
FNTT — Found Nail with Tin Tab
FPK — Found PK Nail
FPKD — Found PK Nail with Disk
FRRS — Found Rail Road Spike
/CO — In Pavement Cut Out
Prepared By: Regina C. Kamer, PSM#4363
Kamer Surveying, Inc. LB#7357
°p I FND#5
RC 4049
X0.33'E
o
LEGAL DESCRIPTION
Lot 12, OAKS AT INDIAN RIVER, according
to the Plat thereof, as recorded in Plat
Book 33, page(s) 10 and 10A, Public
Records pf St Lucie County, Florida.
VACANT \ \ 6"Deep Detention Swale
/ Lot 11
0„ w 187.58' (P) \
�`� 552.501
h N53 0656"E 187.89' (M) \
I 1
—4�12 �7g160
d
m
—� — -----95.20'-------
°I
I Lot 12
One Story Re,'k" Lane
En121 Eden Creek
m
o�
°I
7
o I �33
1n \
°
C \10
�7S36I \\
\\ N
�7Q
30 --—
u7 \
Water L1ner
L0 ell
proposed W
14.25-1
�7S
z� ----
14.32 �.
`S8`9 09 �s FND#5
S89 g �S� C 4049 7g 06
os, 66
r-J %J \
Prepared For:
Mr. Young & Ms. Barry
15 t Lot
used Concrete Drive \
Prop �
w
•� - 1g.3
3 Garage
El' 15 67
e
i ResidencFloor t 16.0
e Story FinlshednatelY Height
.O PEos r ,eld
lepat d toApprd 0 F
\a sublet
1.00
16.68
C' Wit° 729
0 7
co
o/
II
• 33"E 194 g5 (M�(P)
00
N45 06
- l a w/ VACANT
Lot 13 ,
�73
96
I
I
77
I
FND - PCP
LS1272
N,
W \
Q0
rn,
/ PGP
\ Fop 512�2 ��,� g03o0,
R'1.06 30
�D�1
56 5
N35.9 PG \
L--68•17' / \
R=50.0011 ' 1
6=78'07' 14 \
FN 5
RC D 049 Ga?®5
`3 7Q
T
l 0-�
I t0,ry � �r•`33
17
\
-t \
0
n
\ _n
CD
0
U)
\ 6— n (°•
I
d
ao
T, \ % I
n
\ � I
I \ \ I
\ J
/ g.00 \ Tan;
w 12.67 5.5 FC D40
cw
o �50
5.5
0
�722'
-�-77
. SO
A-77
.
6S
A 70
.
90
1
I �6 P'
s) co
10.16' �` o
o d flco �o t00 FND — PCP
72
,0 A u, \ o LS 12
O O. O L
Center Line
o F� �� L=197.41' i
oo' /o Cl�„�7) OO 6 22 �12'42>,
��pp 0- `
cm`Y�p � L=98.70'
,� \ 7�9 R=50 00'
7 0A=113.06'09"
o /
ti Sao -------------
Co 77
OOS(
Ch
c" I
o I I
b I
7�90
90 I
I
I
I I
I
I
I I
I I
KARNER SURVEYING, INC. Rp ryg i n a Dig t "signed
by Regina
Residential & Commercial Surveying Services i< rller Ka
Darner, PSM
2021.01.L2
2740 SW Martin Downs Blvd.#333, Palm City, F1.34990 , �$M 13:13:19-05'00'
Phone: (772)288 7206 Fax:(772)223 8181 `--
VWW.KARNERSURVEYINGINC.COM learner®comcost.net A2ErVeb .dS,� y- sea
Date:
1.9.2021
Revision 11-1pt/on,
Site Plan
1.12.2021
Add Water Line