Loading...
HomeMy WebLinkAboutLATERAL TOE-NAIL DETAILAUGUST 1, 2016 I LATERAL TOE -NAIL DETAIL Mil -TOENAIL a o0 0 00 MiTek USA, Inc. N ER DBY '�' L J A MITek Allglat° MiTek USA, Inc. Page 1 of 1 (Rt NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE BOTTOM CHORD SPECIES FOR MEMBERS OF DIFFERENT SPECIES. SQUARE CUT TOE -NAIL SINGLE SHEAR VALUES PER NDS 2005 (lb/nail) DIAM. SP DF HF SPF SPF-S 0 .131 88.1 80.6 69.9 68.4 1 59.7 01 .135 93.5 85.6 74.2 72.6 63.4 J I .162 118.3 108.3 93.9 91.9 80.2 z A 28 84.1 76.9 66.7 1 65.3 57.0 C .131 88.1 80.6 69.9 68.4 59.7 N .148 106.6 97.6 84.7 82.8 72.3 n 0 .120 73.9 67.6 58.7 57.4 50.1 O .128 84.1 76.9 66.7 65.3 57.0 J o .131 88.1 80.6 69.9 68.4 59.7 °' .148 706.6 97.6 84.7 82.8 72.3 VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d (0.162- X 3.5-) NAILS WITH SPF SPECIES BOTTOM CHORD For load duration increase of 1.15: 3 (nails) X 91.9 (lb/nail) X 1.15 (DOL) = 317.0 lb Maximum Capacity 45 DEGREE ANGLE BEVEL CUT SIDE VIEW (2x3) 2 NAILS \ / NEAR SIDE NEAR SIDE 5.00 ° 45.00 ° U2 I SIDE VIEW '' (2x4) U2 ,� I 3 NAILS NEAR SIDE % \ I NEAR SIDE i I NEAR SIDE VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW SIDE VIEW (2x4) (20) 3 NAILS 2 NAILS \ i NEAR SIDE \/' --�-!----a FAR SIDE I� q NEAR SIDE i �� =- NEAR SIDE ---- i FAR SIDE SIDE VIEW (W) 4 NAILS / NEAR SIDE t / ----I FAR SIDE NEAR SIDE 1_- V--- FAR SIDE SIDE VIEW (2x6) 4 NAILS / NEAR SIDE NEARSIDE NEAR SIDE V`1 NEAR SIDE AUGUST 1, 2016 LATERAL TOE -NAIL DETAIL M� II-TOENAIL_SP DO (R) MiTek USA, Inc. Page 1 of 1 NOTES: \✓ 00 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER O �O AND MUST HAVE FULL WOOD SUPPORT. (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. MiTek USA, Inc. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES ENGINEEREDFOR MEMBERS OF DIFFERENT SPECIES. 0_1 'T_"_' a mar°rc nmmlo THIS DETAIL APPLICABLE TO THE THREE END DETAILS SHOWN BELOW OE -NAIL SINGLE SHEAR VALUES PER NDS 2001 (lb/nail) DIAM. SP DF HF SPF SPF-S 19 ."1 88.0 80.6 69.9 68A 59.7 O.135 93.5 85.6 74.2 72.6 63.4 U") .162 108.8 99.6 86.4 84.5 73.8 cri z Z .128 74.2 67.9 58.9 57.6 50.3 0 .131 75.9 69.5 60.3 59.0 51 A 71 N .148 81.4 74.5 64.6 63.2 52.5 cri VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d (0.162" X 3.5") NAILS WITH SPF SPECIES BOTTOM CHORD For load duration increase of 1.15: 3 (nails) X 84.5 (lb/nail) X 1.15 (DOL) = 291.5 lb Maximum Capacity `ANGLE MAY VARY FROM 30 ° TO.60 ° 45.00 ° VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW (2x3) 2 NAILS / NEAR SIDE X NEAR SIDE SIDE VIEW SIDE VIEW (2x4) (24) 3 NAILS 4 NAILS -1 NEAR SIDE , NEAR SIDE v NEAR SIDE NEAR SIDE NEAR SIDE I NEAR SIDE NEAR SIDE ANGLE MAY 1 VARY FROM 30 ° TO 60 ° 45.00 ° L ANGLE MAY VARY FROM 30 ° TO 60 ° 45.00 ° L .. I