HomeMy WebLinkAboutLATERAL TOE-NAIL DETAILAUGUST 1, 2016 I LATERAL TOE -NAIL DETAIL Mil -TOENAIL
a o0
0 00
MiTek USA, Inc.
N ER DBY '�'
L J
A MITek Allglat°
MiTek USA, Inc. Page 1 of 1
(Rt
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER
AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE BOTTOM CHORD SPECIES
FOR MEMBERS OF DIFFERENT SPECIES.
SQUARE CUT
TOE -NAIL SINGLE SHEAR VALUES PER NDS 2005 (lb/nail)
DIAM.
SP
DF
HF
SPF
SPF-S
0
.131
88.1
80.6
69.9
68.4
1 59.7
01
.135
93.5
85.6
74.2
72.6
63.4
J
I
.162
118.3
108.3
93.9
91.9
80.2
z
A 28
84.1
76.9
66.7
1 65.3
57.0
C
.131
88.1
80.6
69.9
68.4
59.7
N
.148
106.6
97.6
84.7
82.8
72.3
n
0
.120
73.9
67.6
58.7
57.4
50.1
O
.128
84.1
76.9
66.7
65.3
57.0
J
o
.131
88.1
80.6
69.9
68.4
59.7
°'
.148
706.6
97.6
84.7
82.8
72.3
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d (0.162- X 3.5-) NAILS WITH SPF SPECIES BOTTOM CHORD
For load duration increase of 1.15:
3 (nails) X 91.9 (lb/nail) X 1.15 (DOL) = 317.0 lb Maximum Capacity
45 DEGREE ANGLE
BEVEL CUT
SIDE VIEW
(2x3)
2 NAILS
\ / NEAR SIDE
NEAR SIDE
5.00 °
45.00 °
U2 I SIDE VIEW
'' (2x4)
U2 ,� I 3 NAILS
NEAR SIDE
% \ I NEAR SIDE
i I NEAR SIDE
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
SIDE VIEW
SIDE VIEW
(2x4)
(20)
3 NAILS
2 NAILS
\ i NEAR SIDE
\/'
--�-!----a FAR SIDE
I� q NEAR SIDE
i ��
=-
NEAR SIDE
---- i FAR SIDE
SIDE VIEW
(W)
4 NAILS
/ NEAR SIDE
t / ----I FAR SIDE
NEAR SIDE
1_- V--- FAR SIDE
SIDE VIEW
(2x6)
4 NAILS
/ NEAR SIDE
NEARSIDE
NEAR SIDE
V`1
NEAR SIDE
AUGUST 1, 2016 LATERAL TOE -NAIL DETAIL M� II-TOENAIL_SP
DO (R) MiTek USA, Inc. Page 1 of 1
NOTES:
\✓ 00 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER
O �O
AND MUST HAVE FULL WOOD SUPPORT. (NAIL MUST BE DRIVEN THROUGH AND
EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
MiTek USA, Inc. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES
ENGINEEREDFOR MEMBERS OF DIFFERENT SPECIES.
0_1
'T_"_'
a mar°rc nmmlo THIS DETAIL APPLICABLE TO THE
THREE END DETAILS SHOWN BELOW
OE -NAIL SINGLE SHEAR VALUES PER NDS 2001 (lb/nail)
DIAM.
SP
DF
HF
SPF
SPF-S
19
."1
88.0
80.6
69.9
68A
59.7
O.135
93.5
85.6
74.2
72.6
63.4
U")
.162
108.8
99.6
86.4
84.5
73.8
cri
z
Z
.128
74.2
67.9
58.9
57.6
50.3
0
.131
75.9
69.5
60.3
59.0
51 A
71
N
.148
81.4
74.5
64.6
63.2
52.5
cri
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d (0.162" X 3.5") NAILS WITH SPF SPECIES BOTTOM CHORD
For load duration increase of 1.15:
3 (nails) X 84.5 (lb/nail) X 1.15 (DOL) = 291.5 lb Maximum Capacity
`ANGLE MAY
VARY FROM
30 ° TO.60 °
45.00 °
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
SIDE VIEW
(2x3)
2 NAILS
/ NEAR SIDE
X NEAR SIDE
SIDE VIEW SIDE VIEW
(2x4) (24)
3 NAILS 4 NAILS
-1 NEAR SIDE , NEAR SIDE
v NEAR SIDE NEAR SIDE
NEAR SIDE I NEAR SIDE
NEAR SIDE
ANGLE MAY
1 VARY FROM
30 ° TO 60 °
45.00 °
L
ANGLE MAY
VARY FROM
30 ° TO 60 °
45.00 °
L ..
I