Loading...
HomeMy WebLinkAboutYOUNG- ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 79/30/2020 4:21 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY YOUNG RESIDENCE Street: City, State, Zip: JENSEN BEACH , FL , 10251 S OCEAN DRIVE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 2342 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=1.05 281.00 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2342.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1760.00 ft² b. Frame - Wood, Adjacent R=11.0 540.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=22.0 2342.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:9.893 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (281.0 sqft.) (2300.0 sqft.) (2342.0 sqft.) (2342.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 42.0 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 175 EF: 0.980 Glass/Floor Area: 0.120 Total Proposed Modified Loads: Total Baseline Loads: 71.10 73.92 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 10-1-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY 1 YOUNG RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 2342 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , JENSEN BEACH , St. Lucie 10251 S OCEAN DRIVE Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2342 23420 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 POWDER RM 42 420 No 0 Yes Yes1 Yes 2 LAUNDRY 60 600 No 0 Yes Yes1 No 3 KITCHEN/DINING 512 5120 Yes 0 Yes Yes1 Yes 4 BATH 2 56 560 No 0 Yes Yes1 Yes 5 BEDROOM 3 156 1560 No 0 1 Yes Yes1 Yes 6 LINEN 8 80 No 0 Yes Yes1 No 7 WIC 3 30 300 No 0 Yes Yes1 No 8 WIC 2 42 420 No 0 Yes Yes1 Yes 9 BEDROOM 2 169 1690 No 0 1 Yes Yes1 Yes 10 HALLWAY 66 660 No 0 Yes Yes1 No 11 FOYER 91 910 No 0 Yes Yes1 Yes 12 LIVING RM 418 4180 No 0 Yes Yes1 Yes 13 M BATH 213 2130 No 0 Yes Yes1 Yes 14 M TOILET 15 150 No 0 Yes Yes1 No 15 M WIC 2 36 360 No 0 Yes Yes1 No 16 M WIC 1 72 720 No 0 Yes Yes1 Yes 17 MASTER BEDROO 356 3560 No 0 1 Yes Yes1 Yes 9/30/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft POWDER RM 2 60 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY 3 512 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -012 ft KITCHEN/DININ 4 56 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2 5 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft BEDROOM 3 6 8 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LINEN 7 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft WIC 3 8 42 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -012 ft WIC 2 9 169 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -026 ft BEDROOM 2 10 66 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALLWAY 11 91 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft FOYER 12 418 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -022 ft LIVING RM 13 213 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -012 ft M BATH 14 15 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M TOILET 15 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 2 16 72 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -012 ft M WIC 1 17 356 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -037 ft MASTER BEDRO # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Gable or Shed Metal 2619 ft² Light 0.2 22 26.6______No586 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2342 ft² N N0 9/30/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 42 ft² 0.1 Wood______POWDER RM Blown 2 Under Attic (Unvented)0 60 ft² 0.1 Wood______LAUNDRY Blown 3 Under Attic (Unvented)0 512 ft² 0.1 Wood______KITCHEN/DININ Blown 4 Under Attic (Unvented)0 56 ft² 0.1 Wood______BATH 2 Blown 5 Under Attic (Unvented)0 156 ft² 0.1 Wood______BEDROOM 3 Blown 6 Under Attic (Unvented)0 8 ft² 0.1 Wood______LINEN Blown 7 Under Attic (Unvented)0 30 ft² 0.1 Wood______WIC 3 Blown 8 Under Attic (Unvented)0 42 ft² 0.1 Wood______WIC 2 Blown 9 Under Attic (Unvented)0 169 ft² 0.1 Wood______BEDROOM 2 Blown 10 Under Attic (Unvented)0 66 ft² 0.1 Wood______HALLWAY Blown 11 Under Attic (Unvented)0 91 ft² 0.1 Wood______FOYER Blown 12 Under Attic (Unvented)0 418 ft² 0.1 Wood______LIVING RM Blown 13 Under Attic (Unvented)0 213 ft² 0.1 Wood______M BATH Blown 14 Under Attic (Unvented)0 15 ft² 0.1 Wood______M TOILET Blown 15 Under Attic (Unvented)0 36 ft² 0.1 Wood______M WIC 2 Blown 16 Under Attic (Unvented)0 72 ft² 0.1 Wood______M WIC 1 Blown 17 Under Attic (Unvented)0 356 ft² 0.1 Wood______MASTER BEDRO Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0POWDER R 0006 10SE Concrete Block - Int Insul 0.20Exterior60.0 ft² ____ 2 11 0POWDER R 0007 10SW Frame - Wood 0.20.1Garage70.0 ft² ____ 3 11 0LAUNDRY0006 10NW Frame - Wood 0.20.1Garage60.0 ft² ____ 4 11 0LAUNDRY00010 10SW Frame - Wood 0.20.1Garage100.0 ft² ____ 5 4.1 0KITCHEN/DI 00012 10SE Concrete Block - Int Insul 0.20Exterior120.0 ft² ____ 6 11 0KITCHEN/DI 0006 10SW Frame - Wood 0.20.1Garage60.0 ft² ____ 7 11 0KITCHEN/DI 0006 10NW Frame - Wood 0.20.1Garage60.0 ft² ____ 8 4.1 0BATH 2 0005 10SW Concrete Block - Int Insul 0.20Exterior50.0 ft² ____ 9 4.1 0BEDROOM 3 00012 10SE Concrete Block - Int Insul 0.20Exterior120.0 ft² ____ 10 4.1 0BEDROOM 3 00013 10SW Concrete Block - Int Insul 0.20Exterior130.0 ft² ____ 11 4.1 0WIC 2 0003 10NE Concrete Block - Int Insul 0.20Exterior30.0 ft² ____ 12 4.1 0WIC 2 0006 10SE Concrete Block - Int Insul 0.20Exterior60.0 ft² ____ 13 4.1 0WIC 2 0003 10SW Concrete Block - Int Insul 0.20Exterior30.0 ft² ____ 14 4.1 0BEDROOM 2 00013 10NE Concrete Block - Int Insul 0.20Exterior130.0 ft² ____ 15 4.1 0BEDROOM 2 00013 10SE Concrete Block - Int Insul 0.20Exterior130.0 ft² ____ 16 4.1 0FOYER0007 10NE Concrete Block - Int Insul 0.20Exterior70.0 ft² ____ 17 4.1 0LIVING RM 00022 10NE Concrete Block - Int Insul 0.20Exterior220.0 ft² ____ 18 4.1 0M BATH 00012 10NW Concrete Block - Int Insul 0.20Exterior120.0 ft² ____ 19 11 0M BATH 00019 10SW Frame - Wood 0.20.1Garage190.0 ft² ____ 20 4.1 0M WIC 1 0003 10NE Concrete Block - Int Insul 0.20Exterior30.0 ft² ____ 21 4.1 0M WIC 1 0003 10SW Concrete Block - Int Insul 0.20Exterior30.0 ft² ____ 22 4.1 0M WIC 1 0006 10NW Concrete Block - Int Insul 0.20Exterior60.0 ft² ____ 23 4.1 0MASTER BE 00018 10NE Concrete Block - Int Insul 0.20Exterior180.0 ft² ____ 9/30/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 24 4.1 0MASTER BE 00019 10NW Concrete Block - Int Insul 0.20Exterior190.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .23 21.3 ft² None______NW LAUNDRY 882 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 SE Low-E Single 1.05 0.25 16.0 ft² 16 ft 0 in 1 ft 4 in NoneMetal None______Yes5 Y 2 SE Low-E Single 1.05 0.25 32.0 ft² 16 ft 0 in 1 ft 4 in NoneMetal None______Yes5 Y 3 SE Low-E Single 1.05 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes9 Y 4 SW Low-E Single 1.05 0.25 15.0 ft² 16 ft 0 in 1 ft 4 in NoneMetal None______Yes10 Y 5 NE Low-E Single 1.05 0.25 15.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes14 Y 6 SE Low-E Single 1.05 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes15 Y 7 NE Low-E Single 1.05 0.25 8.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y 8 NE Low-E Single 1.05 0.25 24.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y 9 NE Low-E Single 1.05 0.25 60.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes17 Y 10 NW Low-E Single 1.05 0.25 9.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes18 Y 11 NE Low-E Single 1.05 0.25 60.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes23 Y 12 NW Low-E Single 1.05 0.25 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes24 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 1008 ft² 1008 ft² 54 ft 10 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1951.7 5107.14.000318Wholehouse .1204201.5Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 9/30/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 42 kBtu/hr 1260 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 175 ft² Attic 18 ft² Prop. Leak Free Attic 70.3 cfm 0.03 0.50______1 1 --- cfm TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 POWDER RM Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN/DINING Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 3 Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 HALLWAY Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING RM 9/30/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1 Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO 9/30/2020 4:21 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������