Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Specs
IL •Smith PROLINE° STANDARD COMMERCIAL -GRADE RESIDENTIAL ENHANCED HEATING ELEMENTS CODE COMPLIANCE COMMERCIAL -GRADE RESIDENTIAL ELECTRIC WATER HEATERS • Dual 4500 watt elements for fast recovery • Meets UBC and ICC National Codes and and reliable operation.* listed with CEC. • Incoloy stainless steel lower element lasts longer than a standard copper element. DYNACLEANW DIFFUSER DIP TUBE • Helps reduce lime and sediment buildup and maximizes hot water output. Made from long-lasting PEX cross -linked polymer (diffuser design is not used on lowboy models.) HIGH ENERGY FACTORS • Eco-friendly non-CFC foam insulation, heat traps and other features combine to yield a higher Energy Factor that maximizes savings on operating costs. CO REGARD'" AN0DE ROD • Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods. BLUE DIAMOND1 GLASS COATING • Provides superior corrosion resistance compared to industry standard glass lining. ENHANCED -FLOW BRASS DRAIN VALVE • Our residential water heaters have a solid brass, tamper resistant, enhanced -flow, ball type, drain valve. • Uses a standard female hose fitting that allows for fast and easy draining during maintenance. • Designed for easy operation, this valve includes an integral screwdriver slot that features a'/4 turn (open/close) radius; which not only permits full straight - through water flow but also a quick and positive shut off. 'Model ENL-20 has a single element. • Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended. APPROVED FOR MANUFACTURED HOUSING • All residential electric water heaters are compliant with HUD Standards for mobile homes/manufactured housing. CERTIFIED TO UL 174 FOR HOUSEHOLD ELECTRIC WATER HEATERS CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE DESIGN -LISTED BY UNDERWRITERS LABORATORIES • Certified at 300 psi test pressure and 150 psi working pressure. • Listed according to UL 174 standards governing storage tank -type electric water heaters. 6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or go to hotwater.com. (�9 November 2018 A. 0. Smith Corporation. All rights reserved. www.hotwater.com 1800.527-1953 Toll -Free USA IA. 0. Smith Corporation 1500 Tennessee Waltz Parkway I Ashland City, TN 37015 Page 1 of 2 AOSRE50608 CSI�Y�I�h I COMMERCIAL -GRADE � RESIDENTIAL ELECTRIC WATER HEATERS Rated Flrst, Hour Rective @ 90'F Rlse ElementVlfatta a 249V g i3rTitenslons m Inches Approx ; Model Numher Nominal - Storage Ra#mg IiEF Sht m� ppP gg ,Capaoty., Volume {Gallons) G„allon Standard Mmrmum Maximum A B ,C VUetght{lbs)` ,U1 hill -: ENT-30t 30 27 48 0,89 21 4500 1000 6000 46-112 39-112 19 95 ENT-40t 40 36 53 0.92 21 4500 3500 6000 61-114 53-114 18 118 ENT-50t 50 46 59 0,92 21 4500 @ 3000 6000 60-112 51-114 20-112 125 ENT-50Wt 50 46 45 0.88 11 - 1000 2500 60-112 51-114 20-112 125 ENT 55t 55 55 72 0.93 21 4500 2500 6000 56-112 48-112 24 145 Sh6ft Models': . ENS13-30* 30 27 50 9.90 21 4500 1000 6000 39 30-112 20 95 ENS-30t 30 27 47 0.89 21 4500 1000 6000 39-314 30-112 22 94 ENS-40t 40 37 55 0.92 21 4500 @ 4500 6000 49-314 40-314 20-112 109 ENS-40Wt 40 37 41 0.88 18 - 1000 4000 49-314 40-314 20-112 109 ENS-50t 50 46 57 0.92 21 4500 2500 6000 49-114 40-318 23 161 Low:ilo To�":Cbnnect:Madels . . ENL-20 19.9 19 MIA NIA 21 4500 1000 6000 30 21-114 20 65 ENLB-30*t 28 26 43 0.89 21 4500 1000 6000 30 21-314 20 90 ENL-30t 28 26 44 0.90 21 4500 1000 6000 311/4 21-314 24 115 ENL-36t 36 33 51 0.92 21 4500 @ 4500 6000 32 24 24 118 ENL-36Wt 36 33 37 0.89 18 - 1000 4000 32 24 24 118 ENL-40t 38 35 50 0.89 21 4500 1000 6000 33 112 24 26 118 ENLB-40*t 38 35 51 0.92 21 4500 ® 4500 6000 32 24 23 118 ENLB-40W*t 38 35 38 0.90 18 - 1000 4000 32 24 23 118 ENLB-50*t 48 44 60 0.93 21 4500 @ 4000 6000 34 25 26.112 172 ENLB-50W*t 48 44 40 0,91 16 1000 3500 34 25 26-112 172 ENL-50t 51 48 54 0.92 21 4500 4000 6000 36 25 261121 172 Male 314" water connections on 8" center. *Models ship with supplied insulation blanket. tFor 10-year tank and 10-year parts warranty, change "E" to "P" in the model number (example: ENT-30 becomes PNT-30). ENL-20 is a single element configuration only. Models requiring a lower wattage than what is listed in the minimum wattage column and showing the @ symbol, will change to a "W" suffix model number. "W" suffix models are available dawn to 1kW. (example: ENS-40 using 4,000 watt elements or less will become "ENS-40W"). Top T&P is not available on the 10 year lowboy models. Dimensionsand specifications subject to change without notice in accordance with our policy of continuous produa improvement. T&P VALVE ACCESS PANEL ACCESS PANEL DRAIN VALVE ANODE OR OPTIONAL TOP T&P LOCATION FOR ENL-20 SECOND ANODE ROD FOR LOWBOYS — OR OPTIONAL TOP T&P (All Other Models) JUNCTION BOX T&P VALVE For technical information call 8001 Smith Corporation © November 2018 A. 0. Smith Corporation. All rights reserved. Page 2 of 2 www.hotwater.com 1800.527-1953 Toll -Free USA I A. 0. Smith Corporation 1 500 Tennessee Waltz Parkway I Ashland City, TN 37015 AOSRE50608