HomeMy WebLinkAboutResidential Plans Examiner Review FormACCK e Aroraaryosemsaranem County, Town, Municipality, Jurisdiction Header Information Contractor Florida Breeze Mechanical License # CAC1814113 Building Plan # EASTHAM Home Address (Street or Lot#, Block, Subdivision) CREEKSIDE LOT 71 REQUIRED ATTACHMENTS' Form RPER 1.01 8 Mar 10 ATTACHED Manual A Form (and supporting worksheets): Yes 0 No ❑ or MJ1AE Form' (and supporting worksheets): Yes ❑ No ❑X OEM performance data (heating, cooling, blower): Yes ❑X No ❑ Manual D Friction Rate Worksheet: Yes ❑ No ❑X Dud distribution system sketch: Yes ❑ No ❑X ` esign Loonanions Building Construction Information Winter Design Conditions Building " Outdoor temperature 42 OF Orientation (Front door faces) North Indoor temperature 70 OF North, East, West, South, Northeast, Northwest, Southeast, Southwest ,.t Total heat loss 25729 Btu/h Number of bedrooms 3 Summer Design Conditions Conditioned floor area 1747 Sq Ft Outdoor temperature 90 of Number of occupants 4 Indoor temperature 75 OF Windows Grains difference 61 0 Gr @ 50 % Rh Eave overhang depth Ft Roof Sensible heat gain 19699 Btu/h Internal shade <— Eave Latent heat gain 5494 Btu/h Blinds, drapes, eft Depth Window Total heat gain 25192 Btu/h Number of skylights — 0 40 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Heat pump Equipment type Heat pump 1385 CFM Heating CFM Furnace, Had pump, Boiler, etc. Air conditioner, Heat pump,etc Model 25HBC530A*030* Model 25HBC530A*030* Cooling CFM 1 A CFM Heating output capacity 28200 Btu/h Sensible cooling capacity 21300 Btu/h Heat pumps - capacity at whiter design outdoor conditions Latent cooling capacity 71 0 0 Btu/h Auxiliary heat output capacity Btum Total cooling capacity 28400 Btu/h HVAC DUCT DISTRIBUTION Design airflow 1480 CFM Longest supply duct: Ft Duct Materials Used (circle) Trunk Duct: Duct board le Sheet metal, External Static Pressure (ESP) 0.46 IWC Longest return duct: 17 Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL) 0 25 IWC Available Static Pressure (ASP) 0.213 IWC ASP = ESP - CPL Contractor's Printed Name Contractor's Signature Total Effective Length (TEL) 63 Ft Friction Rate: 0.34 IWC Friction Rate = (ASP ■ 100) + TEL Branch Dud: Duct board, lax Sheet metal, Lined sheet metal, Other (specify) Date 3/12/2020 = The AHJ shag have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of Instructions. If abridged version or Manual J is used for load calculation, then verify residence meets requirements, we Abridged Edition Checklist on page 13 of Instructions. Form generated by ACCAapproved Manual J Eighth Edition Version 2 Elite Software Rhvac program.