Loading...
HomeMy WebLinkAboutDBPR Approvals NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 1 of 6 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD®, Timberline® Natural Shadow®, Timberline® American Harvest®, and Fortitude™ Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 2 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HD®, Timberline® Natural Shadow®, Timberline American® Harvest®, and Fortitude™ Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications Product Description GAF Timberline HD® Manufacturing Locations #1, 2, 3, 4, 5, 6, 7 13 1/4” x 39 3/8” TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with a laminate profile GAF Timberline Natural Shadow® Manufacturing Locations #1, 2, 3, 4, 5, 6, 7 13 1/4” x 39 3/8” TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with a laminate profile GAF Timberline® American Harvest® Manufacturing Locations #2, 4, 5, 6 13 1/4” x 39 3/8” TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with a laminate profile GAF Fortitude™ Manufacturing Location #4 13 1/4” x 39 3/8” TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with a laminate profile MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis, TX 6. Tuscaloosa, AL 7. Dallas, TX NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 3 of 6 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16 Underwriters Laboratories, Inc. Underwriters Laboratories, Inc Underwriters Laboratories, Inc Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. PRI Asphalt Technologies, Inc. Underwriters Laboratories, Inc. PRI Asphalt Technologies, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Center for Applied Engineering ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 11CA48924 10CA21994 10CA28717 05CA47541 06CA31580 GAF-101-02-02 06NK05159 GAF-098-02-02 02NK41809 03NK26444 257989 10/24/11 04/22/11 07/26/11 11/10/06 11/30/06 11/02/05 08/09/06 11/08/05 08/11/02 10/17/03 05/13/97 Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. TAS 107 TAS 107 TAS 107 TAS 107 TAS 107 TAS 107 TAS 107 01NK45803 06NK05159 04NK04273 05CA42840 02NK41811 03CA35209 04CA13850 04/13/94 08/09/06 02/20/04 11/11/05 11/11/02 10/17/03 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. TAS 100 TAS 100 TAS 100 TAS 100 GAF-044-02-01 GAF-098-02-01 GAF-101-02-01 GAF-116-02-02 01/13/04 11/08/05 11/09/05 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 ELK-084-02-01 ELK-085-02-01 ELK-086-02-01 ELK-087-02-01 ELK-088-02-01 ELK-107-02-01 ELK-108-02-01 ELK-109-02-01 10/16/02 10/15/02 10/14/02 10/24/02 10/21/02 10/16/02 10/09/03 10/09/03 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 4 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 5 of 6 DETAIL A COURSE LAYOUT FULL FULL 17" OFF 11" OFF 6" OFF 1st 2nd 3rd 4th 5th DECK 5-5/8" Exposure NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 6 of 6 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN END OF THIS ACCEPTANCE BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL22202-R3 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Tuff Shed, Inc. Address/Phone/Email 1777 South Harrison Street Suite 600 Denver, CO 80210 (303) 474-5567 bgrimes@tuffshed.com Authorized Signature Tom Saurey bgrimes@tuffshed.com Technical Representative Patrick Kessler Address/Phone/Email 1777 S Harrison Street Denver, CO 80210 (303) 753-8833 Ext 5617 pkessler@tuffshed.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturer Association Validated By Window and Door Manufacturers Association Referenced Standard and Year (of Standard)Standard Year ASTM E330 2014 TAS 202 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 09/20/2018 Date Validated 09/24/2018 Page 1 of 3Florida Building Code Online 10/29/2020http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquYPIHVa8bq... Date Pending FBC Approval Date Approved 10/02/2018 Summary of Products FL #Model, Number or Name Description 22202.1 Side-hinged Wood Shed Door (Outswing - Double Door) Side-hinged Wood Shed Door (Outswing - Double Door) Maximum Size 80.25" wide by 84" high Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +42/-42 Other: Structural only Certification Agency Certificate FL22202_R3_C_CAC_TUFF456CCL.pdf Quality Assurance Contract Expiration Date 06/14/2028 Installation Instructions FL22202_R3_II_AP-FL-PGEN-03 (Double Door).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 22202.2 Side-hinged Wood Shed Door (Outswing Double Door) HVHZ Side-hinged Wood Shed Door (Outswing - Double Door) HVHZ Maximum Size 80.25" wide by 84" high Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +54/-54 Other: Structural only Certification Agency Certificate FL22202_R3_C_CAC_TUFF456CCL.pdf Quality Assurance Contract Expiration Date 06/14/2028 Installation Instructions FL22202_R3_II_AP-FL-PGEN-03 (Double Door - HVHZ).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 22202.3 Side-hinged Wood Shed Door (Outswing Single Door) Side-hinged Wood Shed Door (Outswing - Single Door) Maximum Size 56" wide by 83.75" high Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +42/-42 Other: Structural only Certification Agency Certificate FL22202_R3_C_CAC_TUFF456CCL.pdf Quality Assurance Contract Expiration Date 06/14/2028 Installation Instructions FL22202_R3_II_AP-FL-PGEN-02 (SIngle Door).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 22202.4 Side-hinged Wood Shed Door (Outswing Single Door) HVHZ Side-hinged Wood Shed Door (Outswing - Single Door) HVHZ Maximum Size 56" wide by 83.75" high Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +54/-54 Other: Structural only Certification Agency Certificate FL22202_R3_C_CAC_TUFF456CCL.pdf Quality Assurance Contract Expiration Date 06/14/2028 Installation Instructions FL22202_R3_II_AP-FL-PGEN-02 (SIngle Door - HVHZ).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Page 2 of 3Florida Building Code Online 10/29/2020http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquYPIHVa8bq... Page 3 of 3Florida Building Code Online 10/29/2020http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquYPIHVa8bq... 10/12/2018 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvMdF6zR4iHLm1meckcmccE%2bTQwzL8fUG4%3d 1/3   BCIS Home   Log In   User Registration    Hot Topics   Submit Surcharge   Stats & Facts   Publications   Contact Us   BCIS Site Map   Links   Search      Product Approval  USER: Public User   Product Approval Menu > Application Detail   FL #FL5822­R7 Application Type Revision Code Version 2017 Application Status Approved   Comments Archived   Product Manufacturer Smart Vent Products, Inc. Address/Phone/Email 430 Andbro Dr Unit 1 Pitman, NJ 08071 (877) 441­8368 info@smartvent.com   Authorized Signature Michael Graham info@smartvent.com   Technical Representative Michael Graham Address/Phone/Email 430 Andbro Dr Unit 1 Pitman, NJ 08071 (877) 441­8368 info@smartvent.com   Quality Assurance Representative Address/Phone/Email   Category Structural Components Subcategory Products Introduced as a Result of New Technology   Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer   Evaluation Report ­ Hardcopy Received   Florida Engineer or Architect Name who developed the Evaluation Report Hermes F. Norero P.E. Florida License PE­73778 Quality Assurance Entity Architectural Testing, Inc., an Intertek Company Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E.   Validation Checklist ­ Hardcopy Received   Certificate of Independence FL5822_R7_COI_Smart Vent COI SS 2017­08­18 .pdf   Referenced Standard and Year (of Standard)   Equivalence of Product Standards Certified By     Sections from the Code   1612.5(1)(1.2) 1708.2     10/12/2018 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvMdF6zR4iHLm1meckcmccE%2bTQwzL8fUG4%3d 2/3   Product Approval Method Method 2 Option B   Date Submitted 08/17/2018 Date Validated 08/17/2018 Date Pending FBC Approval 08/23/2018 Date Approved 10/08/2018   Summary of Products FL #Model, Number or Name Description 5822.1 SmartVent Model #1540­510 Dual Function Flood and Ventilation Vent Limits of Use  Approved for use in HVHZ: Yes  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +100/­100  Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). Installation Instructions  FL5822_R7_II_1540­510 SS 2017­08­23.pdf  Verified By: Hermes F. Norero, P.E. Florida P.E. 73778  Created by Independent Third Party: Yes Evaluation Reports  FL5822_R7_AE_PER5022 SS 2018­06­20.pdf  FL5822_R7_AE_SmartVent ­ Impact Requirements SS 2017­ 08­23.pdf  Created by Independent Third Party: Yes 5822.2 SmartVent Model #1540­511 Dual Function Flood and Ventilation Vent Limits of Use  Approved for use in HVHZ: Yes  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +100/­100  Other: One vent may be used for up to 400 sq. ft. of interior space (minimum 2). Installation Instructions  FL5822_R7_II_1540­511 SS 2017­02­28.pdf  Verified By: Hermes F. Norero, P.E. Florida P.E. 73778  Created by Independent Third Party: Yes Evaluation Reports  FL5822_R7_AE_PER5022 SS 2018­06­20.pdf  FL5822_R7_AE_SmartVent ­ Impact Requirements SS 2017­ 08­23.pdf  Created by Independent Third Party: Yes 5822.3 SmartVent Model #1540­520 Insulated Flood Vent Limits of Use  Approved for use in HVHZ: Yes  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +100/­100  Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). Installation Instructions  FL5822_R7_II_1540­520 SS 2017­08­23.pdf  Verified By: Hermes F. Norero, P.E. Florida P.E. 73778  Created by Independent Third Party: Yes Evaluation Reports  FL5822_R7_AE_PER5022 SS 2018­06­20.pdf  FL5822_R7_AE_SmartVent ­ Impact Requirements SS 2017­ 08­23.pdf  Created by Independent Third Party: Yes 5822.4 SmartVent Model #1540­521 Insulated Flood Vent Limits of Use  Approved for use in HVHZ: Yes  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +100/­100  Other: One vent may be used for up to 400 sq. ft. of interior space (minimum 2). Installation Instructions  FL5822_R7_II_1540­521 SS 2017­02­28.pdf  Verified By: Hermes F. Norero, P.E. Florida P.E. 73778  Created by Independent Third Party: Yes Evaluation Reports  FL5822_R7_AE_PER5022 SS 2018­06­20.pdf  FL5822_R7_AE_SmartVent ­ Impact Requirements SS 2017­ 08­23.pdf  Created by Independent Third Party: Yes 5822.5 SmartVent Model #1540­524 16" Garage Door Flood Vent Limits of Use  Approved for use in HVHZ: Yes  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: N/A  Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). See Installation Instructions for allowable pressures per door construction. Installation Instructions  FL5822_R7_II_1540­524 SS 2018­08­17.pdf  Verified By: Hermes F. Norero, P.E. Florida P.E. 73778  Created by Independent Third Party: Yes Evaluation Reports  FL5822_R7_AE_PER5892 SS 2018­08­17.pdf  FL5822_R7_AE_SmartVent ­ Impact Requirements SS 2017­ 08­23.pdf  Created by Independent Third Party: Yes 5822.6 SmartVent Model #1540­570 Wood Wall Insulated Flood Vent Limits of Use  Approved for use in HVHZ: Yes  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +100/­100  Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). Installation Instructions  FL5822_R7_II_1540­570 SS 2017­02­28.pdf  Verified By: Hermes F. Norero, P.E. Florida P.E. 73778  Created by Independent Third Party: Yes Evaluation Reports  FL5822_R7_AE_PER5022 SS 2018­06­20.pdf  FL5822_R7_AE_SmartVent ­ Impact Requirements SS 2017­ 10/12/2018 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvMdF6zR4iHLm1meckcmccE%2bTQwzL8fUG4%3d 3/3 08­23.pdf  Created by Independent Third Party: Yes 5822.7 SmartVent Model #1540­574 14.5" Garage Door Flood Vent Limits of Use  Approved for use in HVHZ: Yes  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: N/A  Other: One vent may be used for up to 200 sq. ft. of interior space (minimum 2). See Installation Instructions for allowable pressures per door construction. Installation Instructions  FL5822_R7_II_1540­574 SS 2018­08­17.pdf  Verified By: Hermes F. Norero, P.E. Florida P.E. 73778  Created by Independent Third Party: Yes Evaluation Reports  FL5822_R7_AE_PER5892 SS 2018­08­17.pdf  FL5822_R7_AE_SmartVent ­ Impact Requirements SS 2017­ 08­23.pdf  Created by Independent Third Party: Yes   Back    Next   Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850­487­1824   The State of Florida is an AA/EEO employer. Copyright 2007­2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement   Under Florida law, email addresses are public records. If you do not want your e­mail address released in response to a public­records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: