HomeMy WebLinkAboutTrussJQ'i Number. 91191
Ply: 2
SEQN: 26410 / T2 / HIPM
J
m&A CONSTRUCTION /JURADOICOD 1KCD
Qty: 1
FROM:
I
DRW-
Truss Label: Al
Wgt: 663.6 Ibs
I
... / ... 05/22/2020
2 Complete Trusses Required
7- + 39
12 r.8X8 _10X10 =110
5 C D @ E0X
fE
10XI0
_=F 1`0
T1
�4X4(A3) B W2 W2
W2
=AYAIAII
lr
P 0 B1 N M K J
1r2X4 =5X6=I11010 3X4 H1010=-3X8
QX10 M5X14
46'
Loading Criteria (pso Wind Criteria Snow Criteria (Pg, Pf in PSF) Defl/CSI Criteria
A Maximum Reactions (Ibs)
TCLL: 20.00 Wind Sid: ASCE 7-10 Pg: NA Ct: NA CAT- NA PP Deflection in loc Udell U#
. Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph Pf. NA Ce: NA VERT(LL): 0.481 L 9.99 3PO
Lor R* I R- /Rh /Rw /U IRL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(rL): 0.914 L '602 '240
'P 3555 A /2045
BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.073 H - - -
H 3585 11998
EXP: D
Des Ld: 37.00 HORZ(TL): 0.139 H -
Wind reactions based on MWFRS
NCBCLL: O.GO Mean Height: 15.00 ft. Code I Misc Criteria Creep Factor: 2.0
P Brg Width = 8.0 .1Mid,'Ripq,= 1.5
TCDL: �1.0 psf
Bldg Code: FBC 2017 RES Max TC CSI: 0.638
Soffit: 0.00 BCDL: 6.0
-
H Brg Width = - . Min,Req
,
psf
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.382'
Bearing P is a rigid surface.
Spacing: 24.0 C&C Dist a: 4.60 ft Rep Factors Used: No Max YVeb CSI: 0.787
Maximum Top Chord Forces P - ef Ply-(Ibs)
Loc. from endwall: NA Fr/RT:20(0)110(0) Mfg Specified Camber.
Chords Tens.Comp. Chords* . Tens. _Comp:
GCpi: 0.18 Plate Type(s):
A-B 22 -22 D-E 4117 -7590
Wind Duration: 1.60 WAVE, HS VIEW Ver18.02.01A.0205.19 JB-C
2364 -4286 E-F 3607 -6670
Lumber Additional Notes
C-D 3116 -58M F-G 1494 -2902
Value Set: 13B (Effective 611/2013) WARNING: Fumish a copy of this DWG to the
Top chord 2x8 SP 2400f-2.OE :T1 2x4 SP #2: installation contractor. Special care must be taken
Maximum Bot Chord Forces Per Ply (Ibs)
Bot chord 2x8 SP 2400f-2.0E during handling, shipping and installation of trusses.
Chords Tens.Comp. Chords Tens. Comp.
Webs 2x4 SP #2 See "WARNING" note below.
B-0 3953 -2170 L-K 7598 -4334
Lumber value set `1313" uses design values Provide hanger or special connection at right end of
O-N 3810 -2152 K-J 7598 -4334
approved 1/30/2013 by ALSC truss for 3585 Ibs.
N-M 7255 -4171 J-1 5340 -3115
M-L 7255 -4171 I-H 10 -8
Nailnote
Nail Schedule:0.1491x3.25", min. nails
Maximum Web Forces Per Ply (Ibs)
Top Chord: 1 Row @12.00" o.c.
Webs Tens.Comp. Webs Tens. Comp.
Bot Chord: 1 Row @12.00" o.c.
Webs : 1 Row @ 4" o.c.
O-C 225 -28 E-J 828 -105t
Use equal spacing between rows and stagger nails
C-N 2283 -1103 J-F 1516 -561
in each row to avoid splitting.
N-D I206 -1658 F-I 1848 -2779
Loading
D-L 382 0 I-G 3253 -1672
L-E 247 -9 G-H 1003 -1734
#1 hip supports 7-0-0 jacks with no webs.
Left side jacks have 7-0-0 setback with 0-0-0 cant
and 2-0-0 overhang. End jacks have 7-" setback
with 0-0-0 cant and 2-0-0 overhang. Right side jacks
have 0-0-0 setback with 0-0-0 cant and 0-0-0
overhang.
Purfins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to windipressure—
r.
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT- FURNISH THIS DRAWING TO ALL CON -TRACTORS INCLUDING THE INSTALLERS
i
Trusses require extreme care in fabricating, handlinp, shi installing and bracing. Refer to and follow the latest edition of
Component Safety. Information by TPI c Te� to these functions. Installers
B(,*§I'(Building
temporary
an c, practices pHor performing shall provide
bracing per BCS1. Unless noted o herwise,top chord shall have property attached structural sheattIin
a and bottom chord shall have a proger.1y
rigid Locations for
attache, ceding shown lateral restrain( 6f webs shall have bracin q in ailed per BCSI sections
as applicable. Apply plates to each face of truss and position as shown above and on the Joint"Details, unless noted otherwise.
B3 B7 or 10,
' Refe, to TEEL OR
WOO?e T
to
drawings 160A-Z for standard plate positions.
AMBER
RQOF_ R-FLOOR TRUSSES
Alpine, a division of ITW Buildin,�Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 , CO . M MERGE CENTER DRIVE
truss in conformance ANSI PI 1, or for handling sh' * installation and bracing of trusses. A seal an this dravvin r cover
bracinge
uF9n1naVJpqineeriq
yvfth
1i this drawing, indicates acceptance of s I 1
st,n professres on solely for the design shown.(3
and Ose of this is Ke 91
for the ANSI1TPI 1 S 2.
pagSEBPJNG'FL33870
The s I bilit (60)3�8242
_y
rawing any structure responsibility of uildi gDesig%
1 er per
For more information see this lob's -general notes page and these web sites: ALPINE: ustrycom
[CC, e. orm"A
Job Number. 91191
Ply: 1
SEQN. 26359 / T68 / HIPS
/N&A CONSTRUCTION MURADO/COD /KCD
Qty: 1
FROM:
DRW:
Truss Label: A2
Wgt: 254.8 Ibs
.. / ... 05/22/2020
36'5-1/4'
2 D T2 E 6 T2 F 6 T2 G 6 T3
5
=6X6H
T7 CX4
O
T
TZZ
W3 W3 W3
(a) (a) ZZ
W4 �
=-3X8(A1) B ��r
If
A
B2
B3 I 1
B1 �4X4 —H0510 =3X4 =H0510 3X5
—5X6
SEAT PLATE REQ
r 46'
Loading Criteria (pat) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Well L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph Pf: NA Ce: NA VERT(LL): 0.471 M 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(rL): 0.875 M 628 240
B 1851 /- /- /1172 /1096 /285
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.111 1 - -
1 1720 /- /- /840 1985 /-
Des Ld: 37.00 EXP: D HORZ(TL): 0.207 I - -
Wind reactions based on MWFRS
Mean Height:15.00 It Code
NCBCLL: 10.00 TCDL: 4.0 psf Code / Misc Criteria Creep Factor: 2.0
B Width = 8.0 Min Re = 1.5
r9 q -
Soffit: 0.00 BCDL: 6.0 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.780
1 Brg Width = - Min Req = -
Load Duration:1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.578
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Spacing: 24.0 " C&C Dist a: 4.60 ft Rep Factors Used: Yes Max Web CSI: 0.891
Loc. from endwall: not in 6.50 It FT/RT:20(0)/10(0) Mfg Speed Camber.
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:1.60 WAVE, HS VIEW Ver. 18.02.01A.0205.19
A - B 44 0 E - F 3838 -5272
Lumber
B-C 2827 -3804 F-G 3259 -4513
Value Set: 13B (Effective 611/2013)
C - D 2765 -3676 G - H 1402 -2006
D - E 3209 -4312
Top chord 2x6 SP #2 :T1 2x4 SP #2:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2 :W4 2x6 SP #2:
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
B - P 3451 -2808 M - L 5187 -3896
P - O 3286 -2602 L - K 5187 -3896
Bracing
O - N 5132 -3923 K- J 3608 -2760
(a) 1x4 #2 SYP,HF,OR SPF 'T' reinforcement. 80%
N - M 5132 -3923 J -1 42 -47
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ 6' OC.
Maximum Web Forces Per Ply (Ibs)
Loading
Webs Tens.Comp. Webs Tens. Comp.
Bottom chord checked for 10.00 psf non -concurrent
C - P 250 -117 F - K 820 -868
live load.
P - D 271 -90 K - G 1166 -643
D - O 1326 -824 G - J 1750 -2064
Purlins
O-E 958 -1057 J-H 2443 -1685
In lieu of rigid ceiling provide lateral bracing to brace
E - M 329 -88 H -1 1281 -1684
BC @ 24" OC
M - F 268 -51
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1720 lbs.
-WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shi Inca, installing.and bracing. Refer to and follow the latest edition of BCSI (Building
Corral Safety. Information by TPI SBCA) y
onent and toy safPe practices pnor to performing these functions. Installers shall provide tempos
brad�g per BCSI • Unless notes olhe top chord shall have properly attached structural sheathin and bottom chord shall have a pro ryrly
attachetl rigid celfmg Locations sho w permanent lateral restraint of webs shall have bracinc.(LLin ailed per BCSI sections B3, B7 or B10, SCOSTA CORPORATION
as applicable. Apply lates to each face, of truss and position as shown above and on the JoinrDetails, unless noted otherwise. Defer to
drawings 16DA-Z for s�andard plate positions.
WOOD STEEL oR T1MBt_R
ROOF bR FLOOR TRUSSES
Alpine, a division of ITW BuildinWmponents Group Inc. shall not be responsible for any deviation from this drawin ,any failure to build the 3670 COMMERCE CENTER DRIVE
truss in onforma ce with ANSI/TPI 1, or for handlin shi to ,installation and bracin of trusses.A seal on this 9rawmq or cover page sEBRING, FL 33870
listing this drawing, indicates acceptance of prdfess��na� en ineering respongibility solely for the design showh.
yawing
The sUitdbllity (86'3)385-8242
and rise of this for any structure is the responsibillwof the building Designer per ANSI) TPI 1 Sq .2.
For more information see thislob's-general notes page and these web ales: ALPINE: aI ' e' •TPI: SBC.A:
ICC:
Job Number: 91191 1 Ply: 1 SEQN: 26360 / T70 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A3 Wgt: 2352 Ibs .. / ... 05/22/2020
i ill + 32'5-1 /4"
ga5X6 O =5X6 O =5X6 O =5X6 O =5X6
D T2 E T2 F T2 G T2 H
12
T3
OI
T5
�
m2x4
T
T1
W W W -
82X4C
(a) io
m
=3X8(A1) B
W3 W3 W3 W3 a�
Wl W4 0
r
cn
rn
A
B1
Q P 0-344 02 N M L B2 K — J
=3X4 =H0308 =3X4 MH0308m3X4 =4X6
SEAT PLATE REQ.
�
46' '
[lll-2'—{
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,PF in PSF,
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: Ni
TCDL: 7.00
Speed: 159 mph
PF. NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h/2 to h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/112013)
Top chord 2x4 SP M-31 :T1, T3 2x4 SP #2:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113'k2.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1720 lbs.
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.352 N 999 360
VERT( Q: 0.653 N 842 240
HORZ(LL): 0.096 J - -
HORZ(TL): 0.178 J - -
Creep Factor: 2.0
Max TC CSI: 0.750
Max BC CSI: 0.482
Max Web CSI: 0.850
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
*"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 1851 /- /- /1204 /1097 /272
J 1720 /- A 1843 11015 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Big Width =- Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 3203 -4241
B - C 2906 -3833 F - G 2807 -3705
C - D 2640 - 3558 G - H 1589 -2069
D - E 2867 -3709 H - I 60 -35
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - Q 3489 -2852 N - M 4161 -3129
Q - P 3109 -2424 M - L 4161 -3129
P - O 3109 -2424 L - K 3108 -2373
O-N 4176-3172 K-J 889 -694
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - Q
440 -288
F - L
637 -692
Q - D
367 -78
L - G
907 -510
D - O
910 -566
G - K
1338 -1575
O - E
652 - 708
K - H
1789 -1208
E - N
218 - 72
H - J
1426 -1820
N-F
225 -42
I-J
128 -76
SCOSTA CORPORATION
ROOF bR FLOOR TRUSSES
failure to build the 3670 COMMERCE CENTER DRIVE
or cover ge, SEBRING, FL 33870
1 . The sijftability (863)385-8242
ITruss CONSTRUCTION /JURADO/COD /KCD abel: A4 I Wgt 1I Ibs FROM: 26361 / T69 /HIPS I DRW / 05/22/2020
Job Number. 91191 Ply:
i 13 i 295-1/4'
4'6-3/4" --{
a95X6 =5X6 -5X6 -5X6
D T3 E T3 F T3 G
12 T2 T4 T
5 p W W ()n ,05X6 C a
io zo
T1 W4 W4 W4 fb) W3
W2 W5 0
3X8(A1) B zo
A 4X5_
P B1 3 N M B2 L 0 ,1� — I
/2X4 �3X4 �HD308 -3X4 =3X4 =H0308 q6
SEAT PLATE REQ.
�-2'-�
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height: 15.00 It
NCBCLL: 10.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 4.60 it
Loc. from endwall: not in 13.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 :T3 2x4 SP M31:
Bot chord 2x4 SP M31
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Bracing
(a)1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ 6" OC.
(b) 2x4 #3 or better "T' reinforcement. 80% length of
web member. Attach with 16d Box or Gun
(0.135"x3.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
SC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
46'
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Defl/CSI Criteria
PP Deflection in loc Udell U#
VERT(LL): 0.286 E 999 360
VERT(TL): 0.531 E 999 240
HORZ(LL): 0.0851 - -
HORZ(TL): 0.158 1 - -
Code / Misc Criteria
Creep Factor: 2.0
Bldg Code: FBC 2017 RES
Max TC CSI: 0.794
TPI Sid: 2014
Max BC CSI: 0.544
Rep Factors Used: Yes
Max Web CSI: 0.987
HT/RT:20(0)/10(0)
Mfg Specked Camber.
Plate Type(s):
WAVE, HS
VIEW Ver. 18.02.01A.
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1720 lbs.
0205.19
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1848 A A /1231 /715 284
1 1720 /- /- /870 /740 A
Wind reactions based on MWFRS
B Big Width = 8.0 Min Req = 1.5
1 Brg Width = - Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 2722 -3482
B - C 2671 -3739 F - G 1828 -2300
C - D 2710 -3572 G - H 114 -68
D - E 2660 -3384
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - P 3394 -2603 M - L 3659 -2777
P - O 3433 -2721 L - K 3144 -2411
O - N 2943 - 2290 K - J 3144 -2411
N - M 2943 -2290 J -1 1275 -1002
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
P - C
204 -58
L - F
539 -210
C - O
388 -280
F - J
1157 -1288
O - D
505 -264
J - G
1562 -991
D - M
673 -334
G - I
1648 -1962
M-E
487 -420
H-I
237 -13B
E - L
357 -271
*"WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricatingg hand lin shi pin installing'and bracing. Refeir and follow the latest edition of BCSI (Building
Safety Information b TPI and'SBCA) for sateiy practices poor to performing these functions Installers shall provide tempos
BCSI. Unless notes ohervvise,top chord shall have properly attached structural sheathin and bottom chord shall have a prop er ly
id cetlinAq. Locations shown forpermanent lateral restraint of webs shall have bracincLrnsalled per. BCSI sections 63, B7 or B70,
AppTy plates to each face_ of truss and position as.
above and on the JoinfgDetails, unless noted otherwise. Defer to
Of
1pi 1,ortor n
r
accetance
any structure
failure to build the 3670 COMMERCE CENTER
or cover e. SEBRING, FL 33870
If . The s I bllity (863)385-8242
Job Number 91191 Ply: SEQN:
/N&A CONSTRUCTION /JURADO/COD /KCD I Qt t '253.4 Ibs I FROM; 26362 / T56 /HIPS DRW/ 05/22/2020
Truss Label: AS
f 15'
24'5-1 /4"
1
&6-3/4" --{
vD 6
E6 T3 =F 6
O sG 6
12
T2
T4
T
T 5 �
W
W W
W
H %4X6
go5X6 C
(a)
`9
T1
W4 W4
W4
W3 W
`r°
=3X8(A1) B
W2
W6 T
M
A
Q B1
P O
N 02 M L
K B2
J
I
�2X4
=3X4=H0308
=3X4 =3X4 =H0308
=4X4
=4X5
SEAT PLATE REQ.
'
46'
�-2'—{
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: N1
TCDL: 7.00
Speed: 159 mph
IRE NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Sid: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 611/2013)
Top chord 2x4 SP #2 :T2 2x4 SP M-31:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 byALSC
Bracing
(a)1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Puriins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1720 lbs.
Defl/CSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): 0.257 N 999 360
VERT(TL): 0.478 N 999 240
HORZ(LL): 0.077 1 - -
HORZ(TL): 0.143 1 - -
Creep Factor: 2.0
Max TC CSI: 0.900
Max BC CSI: 0.441
Max Web CSI: 0.961
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1848 /- /- 11253 /711 /323
I . 1720 /- A /893 /681 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
1 Brg Width = - Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 2428 -3019
B - C 2644 -3799 F - G 1846 -2220
C - D 2504 -3316 G - H 956 -1225
D - E 2448 -3018
Maximum Bat Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - Q
3447 -2572
M - L
2767 -2083
Q - P
3404 -2697
L - K
2767 -2083
P - O
2778 -2118
K - J
1570 -1203
O-N
2778 -2118
J-1
12 -20
N - M
3163 -2372
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
Q- C
260 0
M- F
468 -207
C - P
553 -486
F - K
855 -1006
P - D
494 -224
K - G
1195 -753
D - N
442 -225
G - J
957 -1104
N - E
337 -266
J - H
1533 -1087
E - M
326 -265
H -1
1374 -1700
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"*IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme pre in fabripting handlin , shi ing, installing,and bracing. Referto and followthe latest edition of BCSI (Building
Safety Information b TPI and SBCA) for sate y practices poor to performing these functions. Installers shall provide temporary
BCSi. Unless noted oherwise,top chord shall have properly ttached structural sheathingp and bottom chord shall have a pro rly
iid ceiling. Loptions shown torpermanent lateral restraint of�webs shall have bracing mslalled per BCSI sections 63, B7 or 10, SCOSTA CORPORATION
e. AppTy plate. to each face, of truss and position as shown above and on the JOinfgDetails, unless noted otherwise. f7efer to WOOD STEEL oR TIMBER
60A Z for standard plate positlo s. ROOF bR FLOOR TRUSSES
of
ivi i,ortor n
r
acce tance
any structure
failure to build the 3670 COMMERCE CENTER DW
Aor cover Cale SEBRING. FL 33870
. The s t bility (863)385-8242
/N&A CO STRUCTION /JURADO/COD /KCD I Qtyt '239.4 Ibs FROM; 26363 / T76 /HIPS DRW/ OS/22/2020
Truss Label: A6
1T i 275-1/4" i 8'6-3/4" �{
SEAT PLATE REQ. SEAT PLATE REQ.
—1Z4„
n,8„
�-z i 173-1/2" + 33'8-1/Z'
46
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: N)
TCDL: 7.00
Speed: 159 mph
Pr: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.00 It
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP M-31 :T1, T2 2x4 SP #2:
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 byALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113'k2.5",min.)nails @ 5' OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
11
X6
TTT
1Y0.318'
1y} (o
N
SEAT PLATE REQ.
Defl/CSI Criteria
♦Maximum Reactions (Ibs)
PP Deflection in loc Udefl L/#
Gravity Non -Gravity
VERT(LL): 0.102 G 999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(TL): 0.189 G 999 240
B 556 P A /426 /176 /362
HORZ(LL): 0.027 J - -
R 1762 /- A /1139 /744 A
HORZ(TL): 0.054 J - -
T 1267 /- A 1770 /433 A
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.705
B Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.822
R Big Width = 8.0 Min Req = 2.1
Max Web CSI: 0.925
T Big Width = 8.0 Min Req = 1.5
Bearings B, R, & Tare a rigid surface.
Mfg Speed Camber.
Bearings B, R, & T require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 1289 -1520
B - C 228 -585 F - G 1695 -2042
C-D 223 -173 G-H 1613 -1914
D - E 179 -97 H - I 1079 -1484
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE I
a division of
any
3srraim or wens snap nave Dracin msranea per es
as shown above and on the Join etails, unless
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - S
486 -312
N - M
2091 -1501
S - R
481 -315
M - L
2091 -1501
Q - P
1024 - 721
L - K
1630 -1222
P - O
1022 -721
K- J
49 -79
O-N
1914 -1371
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
S- C
276 0
F- N
254
-86
C-R
406 -583
N-G
171
-91
R - Q
1185 -1463
G - L
324
-321
D-Q
432 -284
' L-H
514
-211
Q - E
1103 -1544
H - K
543
-494
E - O
902 -533
K -1
1343
-841
O - F
675 -717
I - J '
1015
-1248
of
failure to build the 3670 COMMERCE CENTER
ig or cover page_ , SEBRING, FL 33870
/n. The suitability (863)385-8242
Job Number: 91191 Ply: 1 I SEQN: 26364 / T72 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A7 Wgt: 247.8 Ibs .. / ... 05/22/2020
19
195-1/4"
10'6-W'
o5x6 =5x6 �5X6
E O F T3 G
12 T2 W W T4
5 03X6D e3X6
W6 W6 W5 I DI
g5X6C W3 W4
W9
T1
W1 W2 O O No 4 63 M L K B3 =6 JT
�3A (A1) B 3X4 =1-10308 A4 =3X6 =3X4
B1 S a6XG
inovn
I
2X4 -
N
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
i 124" i 338"
�-2 i 173-1/2' i 338-1/2"
46'
Loading Criteria (pst) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in too L/defl L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
PF NA Ce: NA VERT(LL): 0.091 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.170 F 999 240
B 549 A A /398 /176 /401
BCDL: 10.00 Risk Category:11
Snow Duration: NA HORZ(LL): 0.023 J - -
R 1788 P /- /1195 /753 A
EXP: D
Des Ld: 37.00
HORZ : 0.045 J - -
iTL)
T 1260 P P /792 /J86 A
Mean Height:15.00 ft
NCBCLL: 10.00
Code ! Mlsc Criteria Creep Factor: 2.0
Wind reactions based on MWFRS
TCDL: 4.0 psf
Soffit: 0.00 BCDL:6.0 sf
Bldg Code: FBC 2017 RES Max TC CSI: 0.780
9
B Big Width = 8.0 Min Req = 1.5'
p
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
: ax : .
TPI Std2014 Max CSI0799
R Big Width = 8.0 Min Req = .1
T Big Width = 8.0 Min Req = 1.5
Spacing: 24.0 " C&C Dist a: 4.60 ft
Rep Factors Used: Yes Max Web CSI: 0.678
Bearings B, R, & T are rigid surface.
Loc. from endwall: not in 13.00 ft
FT/RT:200 110(0) Mfg Specked Camber.
()
Bearings B, R, $ T require a seat plate.
GCp!: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 44 0 E - F 1-1522
Value Set: 13B (Effective 6/112013)
B-C 178 -569 F-G 1501 501 -1730730
Top chord 2x4 SP #2
C - D 293 -232 G - H 1408 -1772
Bot chord 2x4 SP #2
D-E 855 -1029 H-1 60 -49
Webs 2x4 SP #2
Lumber value set 1313" uses design values
Maximum Bot Chord Forces Per Ply (Ibs)
approved 1/30/2013 byALSC
Chords Tens.Comp. Chords Tens. Comp.
Loading
B-S 472 -258 N-M 1789 -1264
Bottom chord checked for 10.00 psf non -concurrent
S - R 467 -260 M - L 1570 -1110
live load.
Q - P 52 -59 L - K 1570 -1110
P - O 1146 -782 K - J 1355 -1088
Purlins
O - N 1146 -782
In lieu of rigid ceiling provide lateral bracing to brace
BC aQ 24" OC
Maximum Web Forces Per Ply (Ibs)
Additional Notes
Webs Tens.Comp. Webs Tens. Comp.
WARNING: Fumish a copy of this DWG to the
S - C 276 0 N - F 507 -474
installation contractor. Special care must be taken
C - R 391 -588 F - M 221 -104
during handling, shipping and installation of trusses.
R - Q 1204 -1494 M - G 299 -117
See "WARNING" note below.
Q - D 1218 -.1454 G - K 159 -29
D - P 1175 - 754 K - H 320 - 85
P - E 569 -645 H - J 1428 -1739
E-N 667 -392 I-J 124 -72
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
-IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricating handl!n ship ing, installing,and bracing., Referto and followthe latest edition of BCSI (Building
Safety Information b TPI and SBCA) for sa epty practices nor to performing these functions. Installers shall provide temporary
BCSI. Unl s noted o herwise,top chord shall have properi�r attached structural she.thin and bottom chord shall have a proppeerty
id ceiling. �ocations shown for permanent lateral restraint of webs shall have bracin rns�alled per BCSI sections B3, B7 or B70, SCOSTASCOSTA CO��TION
I e. AppTy plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. f�efer to WOOD STEEL OR TIMBER
60A Z for standard plate positions. ROOF bR FLOOR TRUSSES
Of
TPI 1, or for h
acceptance
any structure
failure to build the 3670 COMMERCE CENTER DRI\
Aor cover gale SEBRING, FL 33870
. The s I bllity (863)365-8242
Job Number. 91191 Ply: 1 1 SEQN: 26365 / T66 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 1 FROM: DRW:
Truss Label: A8 Wgt: 249.2 Ibs .. / ... 05/22/2020
21' 12'5-1/4" 12'6-3/4"
55X6 1112X4 a5X6
E F T3 G
12 T2 , W W7 W T4
5 P;- go3X6D H%3X8
W6 W5 W
W3 W4 1 1112X
®5X6 W 10
T1
B W1 W2 P B2 O LN J L K B3 M6 6 JS
3AX5(A1) 3X4 =3X5 =H0308 B3 m3X6 =3X4
B1 R -6X6
BhvA
SEAT PLATE REQ. SEAT PLATE REQ.
r 12'4 i-
33'8"
2' +1 123-1/2" 33'8-1/2"
SEAT PLATE REQ.
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA VERT(LL): 0.076 F 999 360
1- R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.142 F 999 240
B 549 P P /376 /180 /440
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.015 J - -
Q 1796 P P /1235 1748 P
Des Ld: 37.00 EXP: D
HORZ(TL): 0.031 J - -
S 1258 /- /- /809 /384 /-
Mean Height:15.00 It
NCBCLL: 10.00 TCDL: 4.0 psf
Code
Code / Misc Criteria Creep Factor: 2.0
reactions based on MWFRS
Soffit: 0.00 BCDL: 6.0 psf
Bldg Code: FBC 2017 RES Max TC CSI: 0.878
B Big Width = 8.0 Min Req = 1.5
Load Duration: 1.25 MWFRS Parallel Dist: It to 2h
TPI Std: 2014 Max BC CSI: 0.450
Q Big Width = 8.0 Min Req = 2.1
S Big Width = 8.0 Min Req = 1.5
Spacing: 24.0 " C&C Dist a: 4.60 it
Rep Factors Used: Yes Max Web CSI: 0.923
Bearings B, Q, & S are a rigid surface.
Loc. from endwall: not in 13.00 it
FT/RT:20(0)110(0) Mfg Specked Camber.
Bearings B, Q, & S require a seat plate.
GCp!: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
Value Set: 13B (Effective 6/1/2013)
A - B 44 0 E - F 1409 -1566
B - C 160 -566 F - G 1409 -1566
Top chord 2x4 SP #2
C - D 338 -282 G - H 1380 -1768
Bot chord 2x4 SP M-31 :131 2x4 SP #2:
D - E 933 -1194 H -1 67 -53
Webs 2x4 SP #2
Lumber value set 1313" uses design values
Maximum Bot Chord Forces Per Ply (Ibs)
approved 1/3012013 by ALSC
Chords Tens.Comp. Chords Tens. Comp.
Loading
B - R 469 -225 N - M 1203 -809
Bottom chord checked for 10.00 psf non -concurrent
R - Q 464 -227 M - L 1486 -1019
live load.
P-O 37 -41 L-K 1486 -1019
O - N 1203 -809 K - J 1452 -1153
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
Maximum Web Forces Per Ply (Ibs)
BC @ 24" OC
Webs Tens.Comp. Webs Tens. Comp.
Additional Notes
R - C 276 0 F - M 360 -300
WARNING: Fumish a copy of this DWG to the
C - Q 343 -580 M - G 213 -117
installation contractor. Special care must be taken
Q - P 1216 -1518 G - K 301 -20
during handling, shipping and installation of trusses.
P - D 1235 -1473 K - H 268 -70
See"WARNING" note below.
D-O 1198 -727 H-J 1470 -1804
O - E 498 -451 I - J 136 - 73
E - M 542 -357
-WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
-IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricatingp handling9 shi rng, installing,and bracing., Refer to and follow the latest edition of BCSI (Building
Safety Information b TPI and'SBCA) for -see y practices poor to performing these functions. Installers shall provide tempos
BCSI Unless notes oherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properyrly
]id celfing. Locations shown forpermanent lateral restraint of webs shall have braran rns�alled per BCSI sections 63, B7 or 610, SCOSTA CORPORATION
i e. Apply plates to each face of truss and position as shown above and on the Joinf9Detaiis, unless noted otherwise. F�efer to WOOD STEEL OR TIMEER
60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Of
TPI 1, or for h
acceptance
any sructure
failure to build the 3670 COMMERCE CENTER DRI)
A/i or cover paqe, , SEBRING, FL 33870
. The stjitfibility (863)385-8242
Job Number. 91191 Ply: 1 SEQN: 26366 / T75 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A9 Wgt: 253A Ibs / ... 05/22/2020
23'
8'5-1/4"
14'63/4"
slo" ®bTb
F T3 G
T2
\3X4
12 /4X4
E W H T4
5 17 (e) (a)
/5X6D W7 W6 W
a T1 /3X4 W5 W9 I \
C W
W1
=3X5(A1)B W7 W2 C5X6 B2 = X4 =H0308 = X6-3X4 & X4 3 JT
B1 move — 6
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
1Z4" 33'8"
1► 2 i 12'3-1/2"
46'
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF7 Def ICS1 Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT. NA PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf. NA Ce: NA VERT(LL): 0.074 G 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.137 G 999 240
B 561 !- /- /383 /197 /479
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.021 J - -
R 1754 /- A /1229 /701 A
EXP: D
Des Ld: 37.00
HORZ 0.043 J - -
(�):
T 1269 A A /819 /384 A
Mean Height:l5.OD ft
NCBCLL: 10.00 TCDL: 4.0 psf
Code / Misc Criteria Creep Factor: 2.0
Wind reactions based on MWFRS
Soffit: 0.00 BCDL: 6.0 psf
p
Bldg Code: FBC 2017 RES Max TC CSI: 0.812
B Brg Width = 8.0 Min Req = 1.5
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
:
TPI Std2014 Max BC CSI: 0.757
R Big Width = 8.0 Min Req = 2.1
T Brg Width = 8.0 Min Req = 1.5
Spacing: 24.0 " C&C Dist a: 4.60 It
Rep Factors Used: Yes Max Web CSI: 0.921
Bearings B, R. & Tare rigid surface.
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0) Mfg Specked Camber.
Bearings B, R. & T require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
Value Set: 13B (Effective 611/2013)
A- B 44 0 E - F 1147 -1336
B - C 246 -598 F - G 1296 -1373
Top chord 2x4 SP #2
C - D 338 -296 G - H 1447 -1740
Bot chord 2x4 SP #2
D - E 307 -238 H -1 1101 -1514
Webs 2x4 SP #2
Lumber value set "1313" uses design values
Maximum Bot Chord Forces Per Ply (Ibs)
approved 1/30/2013 byALSC
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B-S 499 -345 N-M 1408 -935
(a) 1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
S - R 494 -347 M - L 1408 -935
length of web member. Attach with 8d Box or Gun
Q - P 914 -671 L - K 1628 -1194
(0.113"x2.5",min.)nails @ 5' OC.
P - O 1252 -829 K - J 33 -56
O - N 1252 -829
Loading
Bottom chord checked for 10.00 psf non -concurrent
Maximum Web Forces Per Ply (Ibs)
live load.
Webs Tens.Comp. Webs Tens. Comp.
Purlins
S-C 275 0 F-N 229 -118
In lieu of rigid ceiling provide lateral bracing to brace
C - R 438 -591 N - G 223 -157
BC @ 24" OC
R - Q 1092 -1447 G - L 342 -159
D - Q 283 -224 L - H 317 -209
Additional Notes
Q - E 1125 -1507 H - K 516 -499
WARNING: Furnish a copy of this DWG to the
E - P 425 -124 K - I 1409 -930
installation contractor. Special care must be taken
P - F 234 -207 I - J 996 -1242
during handling, shipping and installation of trusses.
See "WARNING" note below.
*"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
of
m L.ocanons snown Tor ermaneni iaierai restramT oT weos span nave DracinccLLrnstaneo per bL;bi secuons tii, tT/ or b iu, — SCOSTA CORPORATION
pp y plates to each face o truss and position as shown above and on the Join, etails, unless noted otherwise. Defer to WOOD STEEL OR TIMBER
for standard plate positions. ROOF bR FLOOR TRUSSES
of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing any failure to build the 3670 COMMERCE CENTER DRIT
nce with ANSI PI 1, or for handl!n sh! !n , installation and bracin of trusses. A seal on this 31rravnng or covr page sEBRING, FL 33870
incl indicates acceptance of prdfess{TrQna� en ineering responsibjid solely for the design shown. Thee. uFtability (863)385-8242
i Cawing for any structure is the responsibilit}�of the 6uildiftg Desigrfer per ANSI7rPl 1 Sec.2.
Job Number: 91191 Ply: 1 SEQN: 26367 / T10 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A10 Wgt: 285.6 Ibs / ... 05/22/2020
r 24'6-12"- "1W5/1,6°4'0.5116"14'1-5116"—�
SEAT PLATE REa. SEAT PLATE REQ.
k124"�
2 +i 12'3-12"
i 46'
Loading Criteria (pst)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height: 15.09 ft
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)110(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF -r reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
rn1
33'8-12"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.101 H 999 360
VERT(TL): 0.188 H 999 240
HORZ(LL): 0.016 L - -
HORZ(TL): 0.033 L - -
Creep Factor: 2.0
Max TC CSI: 0.831
Max BC CSI: 0.746
Max Web CSI: 0.804
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
*"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING l
of
SEAT PLATE REQ.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 553 /- /-
/355 /198 /510
U 1779 /- /-
/1261 /645 P
W 1262 /- /-
1815 /376 /-
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
U Big Width = 8.0
Min Req = 2.1
W Big Width = 8.0
Min Req = 1.5
Bearings B, U, & W are
a rigid surface.
Bearings B, U. & W require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A-B 44 0
F-G 1294 -1217
B - C 229 -579
G - H 1372 -1356
C - D 406 -350
H -1 1399 -1422
D - E 1058 -1269
1- J 1395 -1617
E - F 1291 -1385
J - K 1405 -1836
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-V
482 -295
Q-P
1217 -775
V - U
477 -298
P - O
1408 -959
T-S
37 -41
O-N
1647 -1204
S - R
1135 -780
N - M
1647 -1204
R-Q
1135 -780
M-L
48 -57
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
V- C
275 0
G- P
E23
-591
C - U
421 -595
P - H
802
-773
U-T
1138 -1479
H-0
190
-155
T-D
1162 -1419
0-1
347
-175
D - S
1293 -897
0- J
V1
-329
S - E
511 -477
J - M
351
-206
E - Q
251 -87
M - K
1628
-1178
F-Q
210 -78
K-L
1032
-1202
un L-ocrauons snown ror ermanenT Larerai resiraim or wens snan nave oracin msrauea per LsasL secrions Lsa, is 1 or bi u, - SCOSTA CORPORATION
pp y plates to each face o truss and position as shown above and on the Join etails, unless noted otherwise. kefer to WOOD STEEL OR TIMBER
fOr standard plate positions. ROOF bR FLOOR TRUSSES
of ITW Buildingg�Components Group Inc. shall not be responsible for any deviation from this drawing any failure to build the 3670 COMMERCE CENTER DRI1
ncewith ANSITTPI 1, or for handling shipginq, installation and bracing of trusses. A seal on this drawing or cover page SEBRING, FL 33870
in indicates acceptance of pr fesstt na en ineerin respponsibilitysolely forthedesignshown. The s0itftbility (863)385.8242
L utawing for any structure is the responsibilit�of the guildtiig Designer per ANSIrrPI 1 SQ .2.
Job Number. 91191 Ply: 1 SEQN: 26368 / T44 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW.
Truss Label: A11 Wgt: 270.2 Ibs / ... 05/22/2020
SEAT PLATE REQ.
i12a"
(-2' -}- 123-1/2"
Loading Criteria (psfl
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
252-1/2" -' 47-7/W—f-,T0-6fW (- 1215/16,
SEAT PLATE REQ.
46
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: N/
Speed: 159 mph
Pf: NA Ce: NA
Enclosure: Closed
Lu: NA Cs: NA
Risk Category: II
Snow Duration: NA
EXP: D
Mean Height:15.23 ft
BCDL: 4.0 psf
Code / Misc Criteria
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 It
FT/RT:20(0)/10(0)
GCpf: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "136" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
SEAT PLATE REQ.
33V
33'sv2"
i11
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc Udefl U#
Gravity Non -Gravity
VERT(LL): 0.090 G 999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(rL): 0.167 G 999 240
B 551 /- /- /349 /199 /524
HORZ(LL): 0.015 K - -
S 1784 P P /1258 /638 P
HORZ(TL): 0.031 K - -
U 1261 P P /806 /373 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.707
B Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.773
S Brg Width = 8.0 Min Req = 2.1
Max Web CSI: 0.837
U Brg Width = 8.0 Min Req = 1.5
Bearings B, S. & U are a rigid surface.
Mfg Specified Camber.
Bearings B, S, & U require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 F- G 1342 -1336
B - C 239 -575 G - H 1459 -1514
C - D 419 -359 H -1 1483 -1702
D-E 1119 -1294 I-J 1411 -1770
E - F 1329 -1367
""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
of
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - T
478 -287
O - N
1595 -1188
T - S
473 -289
N - M
1595 -1188
R - Q
47 -52
M - L
1600 -1222
Q-P
1154 -800
L-K
34 -40
P - O
1154 -800
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
T- C
276 0
O- G
798 -694
C - S
417 -595
G - M
275 -160
S - R
1152 -1486
M - H
388 -261
R-D
1181 -1424
M-1
216 -206
D - Q
1315 -920
I - L
388 -286
Q - E
491 -446
L - J
1602 -1216
E-0
171 -101
J-K
1056 -1207
F - O 685 -577
D ❑ iu cenm LOGaDOnS snown rot ermanem imemi resrrami or wens snap nave Dracin instane0 per CGAI sections tsa, tsr or es�u, - SCOSTA CORPORATION
ca e. App yrlates to each face o truss and position as shown above and on the Join etails, unless noted otherwise. Defer to WOOD STEEL oR NO
is 160A-Z for andard plate positions. ROOF bR FLOOR TRUSSES
a division of ITW Buildi%1omponents Group Inc, shall not be responsible for any deviation from this drawing any failure to build the 3670 COMMERCE CENTER DW
conformance with ANSI 1, orfor handlin shipprn , installation and bmcin of tmsses.A seal on this cJrawmqp or cover pa a SEBRING, FL 33870
this drawing,indicates acceptance of prdfess{'8nit en ineerin__qq resppongibii solely for the design showb. The seft'lifity (863)3B5-8242
;e of this awing for any sVucture is the responsibilitylof the 6uilch g Desig�er per ANSf/TPI 1 S�c.2.
Job Number: 91191 Ply: 1 1 SEQN. 26369 / T51 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: Al2 Wgt: 264.6 Ibs / ... 05/22/2020
252-10 1 67-70 1 4'0-&16°+E---10'1-&16°
F®5X6
/3X4E T2 WO 7 T4 H 6
12 %3X4
b 5 /5X60 W5 W10 I T5
a (a)
T1 W6 wg W1
J,4X
i3X4C W3 W4 W12W
W14
W1 W2 R 82 O P O B3 N M B3 L �3 U
®3X5(A1) B 3X4 =-4X4 EH0308 =3X8 =3X6=3X8 -3X8
LA
81 T S= X6
RiYA
SEAT PLATE REQ. SEAT PLATE REQ.
A" 124° k33'8" -
�- 2' -f 123-M" -E- 33'8-1/2"
46
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.23 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: > 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 it
Fr/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 611/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 :B3 2x4 SP M-31:
Webs 2x4 SP #2
Lumber value set "139' uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF'T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",m!n.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Defl/CSI Criteria
PP Deflection in too Udefl L/#
VERT(LL): 0.087 G 999 360
VERT(TL): 0.162 G 999 240
HORZ(LL): 0.013 E - -
HORZ(TL): 0.027 E -
Creep Factor: 2.0
Max TC CSI: 0.707
Max BC CSI: 0.504
Max Web CSI: 0.818
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
-IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Of
SEAT PLATE REQ.
111
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 551 /- P /349 /200 /524
S 1783 A A /1252 /629 P
U 1261 A A /800 /342 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
S Big Width = 8.0 Min Req = 2.1
U Brg Width = 8.0 Min Req = 1.5
Bearings B, S, & U are a rigid surface.
Bearings B, S, & U require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 44 0 F-G 1315 -1375
B - C 241 -575 G - H 1464 -1592
C - D 418 -358 H -1 1520 -1772
D - E 1103 -1292 I - J 1370 -1673
E - F 1306 -1376
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - T
478 -287
O - N
1792 -1398
T - S
473 -290
N - M
1792 -1398
R - Q
44 -49
M - L
1527 -1198
Q - P
1151 -783
L - K
22 -27
P - O
1151 -783
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
T- C
276 0
O- G
859
-774
C - S
416 -594
G - M
482
-359
S - R
1138 -1486
M - H
444
-349
R-D
1169 -1422
M-1
171
-86
D - Q
1308 -899
I - L
418
-391
Q - E
475 -454
L - J
1552
-1206
E-0
184 -105
J-K
1065
-1211
F - O
645 -478
SCOSTA CORPORATION
ROD ALORRSSEOFUFOTRS
failure to build the 3670 COMMERCE CENTER DRI\
I or cover a e_ SEBRING, FL 33870
1 . The s I bllity (863)385-6242
Job Number. 91191 Ply: 1 SEQN: 26370 / T46 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: Ala Wgt: 261.8 Ibs .. / ... 05/22/2020
r 25'2-10
87-7/8" --(- 4�0-5/16" -(815/16'
Fa5X6
T2 T3
12 /3X4E yW C'i T4 �5X6 H
5 p W5 @X4
o /5X6D ( Wt IO
T5
T1 W6 a
J%4X4
/3X4C W3 W4 W
W14
B W1 W2 Q B2 P O N B3 M B3 L p3 T
a A 5(A1) 3X4 =4X4 =H0308 =M ---5X8 =4X10
B1 S = X6
move
SEAT PLATE REQ.
—124"
2 .'.
SEAT PLATE REQ.
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37es d::
D.00
Mean Height: 15.23 It
.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: > 2h
Spacing: 24.0 "
C&C Dist a: 4.60 It
Loc. from endwall: not in 13.00 It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 byALSC
Bracing
(a) 2x4 #3 or better "T' reinforcement. 80% length of
web member. Attach with 16d Box or Gun
(0.135"x3.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24- OC
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Snow Criteria (Pg, Pt in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE, HS
W.9.
33'8-1/2'
Defl/CSI Criteria
PP Deflection in loc Udell L/#
VERT(I-Q: 0.105 G 999 360
VERT(TL): 0.195 G 999 240
HORZ(LL): 0.019 K - -
HORZ(TL): 0.039 K - -
Creep Factor: 2.0
Max TC CSI: 0.874
Max BC CSI: 0.947
Max Web CSI: 0.985
Mfg Specified Camber.
VIEW Ver: 18.02.01A.0205.19
T�;
TjTTT7j{ A
1'163(18' N
yNT} n
�l
SEAT PLATE REQ.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 550 /- /- /349 /199 /524
R 1787 P A /1247 1621 /-
T 1260 /- /- 1794 /337 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
R Brg Width = 8.0 Min Req = 2.1
T Brg Width = 8.0 Min Req = 1.5
Bearings B, R, & T are a rigid surface.
Bearings B, R, & T require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 44 0 F-G 1291 -1402
B - C 236 -572 G - H 1839 -20M
C - D 420 -358 H -1 1495 -1616
D - E 1078 -1286 I - J 1324 -1609
E - F 1292 -1373
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - S 475 -282 O - N 1144 -758
S - R 471 -284 N - M 2046 -1598
Q - P 49 -56 M - L 1565 -1193
P-O 1144 -758 L-K 13 -17
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
S- C
276 0
N- G
980
-961
C - R
414 -594
G - M
595
-428
R-Q
1129 -1491
M-H
755
-612
Q-D
1158-1428
H-L
112
-190
D - P
1308 -878
L - I
429
-257
P - E
472 -445
L - J
1532
-1205
E - N
194 -121
J - K
1068
-1230
F-N
619 -402
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
**IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricatingg handlingp, sh' ing, installing bracing. Refer to and follow the latest edition of BCSI (Building
Component SafetyInformation btr TPI and'SBCA) %r sate y practices poor to performing these fugctions. Installers shall provide temporary
bracing per BCS1., Unless noted oTherwise,top chord shall have property attached structural sheathmT and bottom chord shall have a properly
attachhed rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracin.(Lins ailed per BCSI sections B3, B7 or 10, SCOSTA CORPORATIC
as applicable. Apply lates to each face of truss and position as shown above and on the Joint -Details, unless noted otherwise. kefer to WOOD STEEL oR 71M81
drawings 160A-Z for s�andard plate positions. ROOF bR FLOOR TRUST
Alpine, a division of ITW Building Components GrouD Inc. shall not be resoonsible for anv deviation from this draWna.anv failure to build the 3670 COMMERCE CENTER
I 1,orforn
acceptance
any structure
Ig. Theesuitability S 863�30658234.i287o
Job Number. 91191 Ply: 1 SEQN: 26371 / T53 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: Al 1 Wgt: 274A Ibs .. / ... 05/22/2020
i 25'2-11T
F-rYr;
107-7/8" 14'0-5/16° 1 9'9-1/8"—�{
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
12'4" 37'313/16"
f- 2' i 12'3.1/2" + 3T4-5/16°
49'7-13/16"
Loading Criteria (psf
Wind Criteria
Snow Criteria (Pg,Pt in PSF)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des d::
Des Ld: 37.00 D
Mean Height:15.23 ft
.00
NCBTCDL:
4.0 psf
Code f Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: > 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.97 It
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 53 2x4 SP M-31:
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/3012013 byALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF'T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
DefIlCSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in too Udell L/#
Gravity Non -Gravity
VERT(LL): 0.203 H 999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(TL): 0.378 H 999 240
B 543 /- A /333 /223 /524
HORZ(LL): 0.038 F - -
T 1935 /- A /1322 /622 /-
HORZ(TL): 0.074 F - -
K 1400 /- A 1931 /395 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.712
B Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.722
T Brg Width = 8.0 Min Req = 2.3
Max Web CSI: 0.989
K Brg Width = 8.0 Min Req = 1.7
Bearings B, T, & K are a rigid surface.
Mfg Specked Camber.
Bearings B, T, & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 F- G 1487 -1571
B - C 333 -556 G - H 2536 -2903
C - D 475 -354 H -1 2145 -2457
D - E 1233 -1424 I - J 2247 -2679
E - F 1456 -1574 J -K 2482 -3064
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - U
460 -256
P - O
2193 -1579
U - T
455 -259
O - N
2928 -2234
S - R
86 -98
N - M
2928 -2234
R - Q
1275 -799
M - L
2777 -2174
Q - P
1275 -799
L - K
2780 -2171
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
U- C
278 0
P- G
1093 -1095
C-T
415 -595
G-0
1049
-821
T - S
1188 -1641
O - H
893
-836
S - D
1214 -1575
H - M
604
-686
D - R
1497 -964
M -1
763
-583
R-E
511 -533
M -J
418
-386
E- P
228 -97
J- L
178
0
F - P
809 -658
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Aquire extreme care in fabricalg handling shi Ing, installing,and bracing. Referto and followthe latest edition of BCSI (Building
Safety Information b TPI q'SBCA)%,Pe y practices poor topeormingthese fugctions. installersshall provide temporarBCSI. Unless noted oherwi,top chord shall have properly attached structural sheathing and bottom chordshallave a propelyid ceilingLocatishownrpermanent lateral restint ofwebsshall have b.cinc�mstalled perBCSItions B367 or 610,eApplatestoeach faof truss and position as shown above and on the Joint Details, unless noted otherwise, f�efer to
604
Z for s�andard plate positions.
of
e to build the 3670 COMMERCE CENTER
Tr page SEBRING, FL 33870
The s0flZility (863)385.8242
Job Number: 91191 Ply: 1 SEQN: 26372 / T63 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A15 Wgt: 264.6 Ibs / ... 05/22/2020
127a1&" 4'0-5/16" } T3116"
FesxA
SEAT PLATE REQ SEAT PLATE REQ. SEAT PLATE REQ.
r1 z4" 3T3-13/16"
123-1/2" 3T45/16"
f 497-13/16"
Loading Criteria (psi)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udell U#
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): 0.219 H 999 360
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.403 H 999 240
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.042 F - -
Des Ld: 37.00
EXP' D
Mean Height:15.23 It
HORZ(TL): 0.081 F - -
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Creep Factor: 2.0
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.862
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Sid: 2014
Max BC CSI: 0.935
Spacing: 24.0 "
C&C Dist a: 4.97 ft
Rep Factors Used: Yes
Max Web CSI: 0.995
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
Mfg Specked Camber.
GCpi: 0.18
Plate Type(s):
VIEW Ver. 18.02.01A.0205.19
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 :B3 2x4 SP M-31:
Webs 2x4 SP #2
Lumber value set "13131" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113'k2.5",min.)nails @ 5' OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC@24"OC
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
T
snc
N�
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 543 /- A
/320 /236 /576
S 1934 A A
11335 /583 A
J 1516 A A
/1091 /452 A
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
S Big Width = 8.0
Min Req = 2.3
J Big Width = 8.0
Min Req = 1.8
Bearings B, S, & J are a rigid surface.
Bearings B, S. & J require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
F- G 1467 -1565
B - C 421 -554
G - H 2403 -2893
C - D 510 -409
H -1 2234 -2668
D - E 1246 -1416
I - J 2252 -2895
E- F 1430 -1565
J- K 44 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-T
458 -253
O-N
2189 -1415
T - S
453 -255
N - M
3374 -2481
R - Q
94 -104
M - L
3374 -2481
Q - P
1269 -702
L - J
2599 -1872
P - O
1269 - 702
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
T-C
278 0
F-O
814
-672
C-S
413 -695
O-G
1051
-1103
S - R
1105 -1640
G - N
982
-693
R - D
1130 -1573
N - H
1053
-1042
D - Q
1497 -866
H - L
916
-938
Q - E
468 -533
L - I
768
-508
E-O
214 -89
—WARNING"' READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin , shi mg, instailing,and bracing., Referto and followthe latest edition of BCSI (Building
Component Safety. Information b TPI and SBCA) for safPe y practices pnor to performing these functions Installers shall provide temporary
bracing per BCS1. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a properly
attached riqgid ceilingp Locations shown for permanent lateral restraint of webs shall have bracinCcL�rns5alled per BCSI sections B3, B7 or, 610, SCOSTASCOSTA CORPO]tA�ON
as applicable. qpp y plates to each face of truss and position as shown above and on the Joinmetails, unless noted otherwise, lkefer to WOOD STEEL OR TIMBER
drawings 160A Aforstandard plate positions.
ROOF bR FLOOR TRUSSES
Aloine. a division of ITVV Buildinc Components Group Inc. shall not be resnonsible for anv deviation from this drawinn.anv failure to build the 36 M
g or cover page 70 SEBRINGEFL 3�i870 —1
IIQ. The s�I gbility (663)365-8242
any
Job Number. 91191 Ply: 1 SEQN: 26373 / T62 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A16 Wgt: 253.4 Ibs / ... 05/22/2020
25' 4-W5 1i 6" 14'5-7/16" 4�0-5
=aAB
O r I
12 B3X4E W6 "+3X5 O
5 p
W (a) (a) (b H T4 05X6 M
o ,
2X4 66X6D W5 W4 T5 T �O
Ti O W3 is W
=3XSfA1) m
ff: sts
=3X5 A7 B RW1 B2 Q P O 63 N M� 64 L v
A ( ) 5X6 -3X4 =H0308 =4X10 =4X4 =4X4KIT
B1 SE X6
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
r— 7'1-1/2" 476-6116"
2'�{� 7'1" 42'6-13/16" 2
t 497-13116"
Loading Criteria (pst) Wind Criteria
Snow Criteria (P9,Pf in PSF) Defl/CS1 Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT. NA PP Deflection in loc Udefl U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA VERT(LL): 0.307 N 999 360
Loo R+ / R- / Rh / Rw / V / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.567 N 900 240
B 371 /- /- /193 /222 /572
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.079 L - -
S 1872 A /- /1315 /587 /-
EXP: D
Des Ld: . 37.00 Mean Height: 15.18 ft
HORZ(TL): 0.145 L - -
J 1724 /- /- 11145 /478 /-
NCBCLL: 10.00 TCDL: 4.0 psf
Code / Misc Criteria Creep Factor: 2.0
Wind reactions based on MWFRS
Soffit: 0.00 BCDL: 6.0 psf
Bldg Code: FBC 2017 RES Max TC CSI: 0.777
B B Width = 8.0 Min Re 1.5
q =
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
TPI Std: 2014 Max BC CSI: 0.596
S Big Width = 8.0 Min Req = 22
J Brg Width = 8.0 Min Req = 1.5
Spacing: 24.0 " C&C Dist a: 4.97 ft
Rep Factors Used: Yes Max Web CSI: 0.912
Bearings B, S, & J are a rigid surface.
Loc. from endwall: not in 13.00 it
FT/RT:20(0)/10(0) Mfg Specked Camber.
Bearings B, S, & J require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
Value Set: 13B (Effective 6/1/2013)
A - B 44 0 F - G 1828 -2212
B - C 471 -494 G - H 2742 -3636
Top chord 2x4 SP #2 :T2, T3 2x4 SP M31:
C - D 378 -373 H -1 2522 -3312
Bot chord 2x4 SP M-31 :131 2x4 SP #2:
D - E 1915 -2678 I - J 2558 -3508
Webs 2x4 SP #2
E - F 1792 - 2212 J - K 44 0
Lumber value set 1313" uses design values
approved 1/30/2013 by ALSC
Maximum Bot Chord Forces Per Ply (Ibs)
Bracing
Chords Tens.Comp. Chords Tens. Comp.
(a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80%
B - S 28 -31 O - N 2845 -1769
length of web member. Attach with 8d Box or Gun
R - Q 2227 -1413 N - M 4867 -3577
(0.113"x2.5",min.)nails @ 6" OC.
Q - P 2354 -1382 M - L 4867 -3577
(b) 2x4 *3 or better "T' reinforcement. 80% length of
P - O 2354 -1382 L - J 3175 -2172
web member. Attach with 16d Box or Gun
(0.135"x3.5",min.)nails @ G' OC.
Maximum Web Forces Per Ply (Ibs)
Loading
Webs Tens.Comp. Webs Tens. Comp.
Bottom chord checked for 10.00 psf non -concurrent
C - R 302 -289 F - O 1347 -1020
live load.
R-S 1241 -1802 O-G 1093 -1192
R - D 1809 -2695 G - N 1003 -639
Purlins
D-Q 332 -1 N-H 1674 -1735
In lieu of rigid ceiling provide lateral bracing to brace
Q - E 269 0 H - L 1670 -1856
BC @ 24" OC
E - O 565 -524 L - I 1144 -778
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
—WARNING'"° READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in jbricating handlin shi prng, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
f Safety In{ormation bTPI and SBCA) for safety practices poor to performing these functions. Installers shall provide temporary
BCSi. Unless noted herHnse,top chord shallhave property attached structuralheathing nd bottmhord shall have a pro rtyid cellinAp Locatinshown forpermanent lateral restraint of webs shall have bracing installed per BCSI sections 63, BI or �10, SCOSTA CORPORATION
60 qpplylates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. f�efer to WooD sTEEL oR TIMBt7t
60A-Z fOr andard plate positions. ROOF bR FLOOR TRUSSES
Wslon of ITW BuildinWmponents Group Inc. shall not be responsible for any deviation from this draw! any failure to build the 3670 COMMERCE CENTER DRIVE
Iformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses A seal on this drawing or cover page SEBRING, FL 33870
drawing indicates acceptance of pr6fessional engmeerin resgprimbility soleiyfor the design show The s r bility (863)385 8242
)f this c7�awing for any structure is the responsibility of the duildirrg Designer per ANSI/TPI 1 Sec.2.
Job Number. 91191 1 Ply: 1 SEQN: 26417 / T15 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: All 1 Wgt: 320.6 Ibs .. / ... 05/22/2020
44-15/16"-1 UZ-7/16 14-0-5116" 1
SEAT PLATE REQ SEAT PLATE REQ. SEAT PLATE REQ.
r--- T1-1/2426-5/16
2 TV + 42'6-13/16 2
497-13/16"
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl1CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT. NA PP Deflection in loc Udefl U#
Gravity
Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA VERT(LL): 0.361 N 999 360
LWR+ / R- / Rh
/ Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.666 N 767 240
B 350 A A
/- 227 A
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.072 F - -
V 1996 A A
A /1164 A
Des Ld: 37.00 EXP: D
Mean Height:15.00 it
HORZ(TL): 0.133 F - -
K 2512 /- /-
/- /1298 /-
NCBCLL: 10.00 TCDL: 4.0 psf
Code
Code / Misc Criteria Creep Factor: 2.0
reactions based on
MWFRS
Soffit: 0.00 BCDL: psf
p
Bldg Code: FBC 2017 RES Max TC CSI: 0.852
B Brg Width = 8.0
Min Req = 1.5
.0
Load Duration:1.25 MWFRS Parallel Dist: 0 to h/2
: ax : .
TPI Std2014 Max CSI0488
V Big Width = 8.0
K Big Width = 8.0
Min Req = 2A
Min Req = 2.1
Spacing: 24.0 " C&C Dist a: 4.97 ft
Rep Factors Used: Varies by IIMb CSI: 0.917
Bearings B, V. & K are a
rigid surface.
Loc. from endwall: not in 9.00 it
FT/RT:20(0)/10(0) Mfg Specked Camber.
Bearings B, V, & K require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp.
Chords Tens. Comp.
Lumber
Value Set: 13B (Effective 6/1/2013)
A- B 44 -44
G - H 1906 -3393
B - C 208 -160
H - I 3137 -5822
Top chord 2x4 SP #2 :T2, T4, T5 2x4 SP M-31:
C - D 1362 -2465
I - J 2504 -5141
Bot chord 2x8 SP 2400f-2.0E :B1 2x4 SP #2:
D - E 1238 -2347
J - K 2560 -5193
Webs 2x4 SP #2
E - F 1538 -2705
K- L 44 -44
Lumber value set "13191" uses design values
F - G 1321 -2346
approved 1/3012013 by ALSC
Special Loads
Maximum Bot Chord Forces Per Ply (Ibs)
--(Lumber Dur.Fac.=1.25 /Plate Dur.Fac =1.25)
Chords Tens.Comp.
Chords Tens. Comp.
TC: From 55 pIf at -2.11 to 55 plf at 51.76
B - V 78 -118
Q - P 2417 -1378
BC: From 20 pit at 0.00 to 20 plf at 49.65
U - T 50 -77
P - O 4113 -2331
BC: 858 lb Conc. Load at 46.52
T - S 2562 -1507
O - N 4113 -2331
Loading
S - R 2240 -1283
N - M 7927 -4267
R - Q 2240 -1283
M - K 4783 -2347
Bottom chord checked for 10.00 psf non -concurrent
live load.
Maximum Web Forces Per Ply (Ibs)
Purlins
Webs Tens.Comp.
Webs Tens. Comp.
In lieu of rigid ceiling provide lateral bracing to brace
U - V 1196 -1929
Q - G 202 -251
BC @ 24" OC
U - C 1158 -1807
G - P 1329 -619
Additional Notes
C - T 2326 -1256
P - H 893 -1444
T - E 499 -548
H - N 1897 -809
WARNING: Furnish a copy of this DWG to the
E - S 240 -210
N -1 1598 -2928
installation contractor. Special care must be taken
S - F 380 -98
I - M 1890 -29W
during handling, shipping and installation of trusses.
F - Q 375 -135
M - J 1808 -791
See "WARNING" note below.
*"WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handling shi rng, installing, and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety. Information by TPI and fabricating,
for safe y practices pnor to performing these functions. Installers shall provide temporary
bracifrg per BCSI. Unless noted o herwise,top chord shall have pmpedy attached structural sheathing and bottom chord shall have a properly
attachhed rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin(cCi�installed per BCSI sections B3, B7 or 10,
as applicable. Apply plates to each face of truss and position as shown above and on the JoinCDetails, unless noted otherwise. kefer to
drawings 160A-Z for standard plate positions.
Alpine, a division of ITW Buildina Comoonents Group Inc. shall not be responsible for anv deviation from this draviina.anv failure to build the
3670 COMMERCE CENTER
SEBRING, FL 33870
(863)385-8242
fim 1,oriorn
acceptance
any structure
Aror cover e
. The suillbility
Job Number: 91191 Ply: 1 SEQN: 26374 / T64 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: Alb 1 Wgt: 238.0 Ibs .. / ... 05/22/2020
21' i8'4-15/16" - -}- 14'5-7/16" --Wq
obxb 5x6
E O F
T2
12 W W - %3X4
5 j000W G T4
f
O®4X6
T1 W6 W5 �6X8(SRS)O Ip2X4
C W4 W3 H T5 66X8
W2 W9
RW1 Q g2 P O" B3 N M L B4 K J
=3AX5(A7) g 3X4 =4X6 =H0308 =3X4 =H0308 =3X4 =3X4
B1 S 11 X6
SEAT PLATE REQ. SEAT PLATE REQ.
r--7'1-1/2" 391-1/16"
1- 2' "1`_ 7-1"
i 46 4-9/16"
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf:.NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des d::
Des Ld: 37.00 D
Mean Height: 15.00 ft
.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Sid: 2014
Spacing: 24.0 "
C&C Dist a: 4.64 it
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 It
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 611/2013)
Top chord 2x4 SP #2 :T2, T4 2x4 SP M31:
Bot chord 2x4 SP #2 :64 2x4 SP M-31:
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1471 lbs.
39'3-9/16"
T
fD
�1
Defl/CSI Criteria
♦Maximum Reactions (Ibs)
PP Deflection in too Udell U#
Gravity Non -Gravity
VERT(LL): 0.219 L 999 360
Lou R+ / R- / Rh / Rw / U / RL
VERT(TL): 0.408 L 999 240
B 356 /- A /217 /172 /440
HORZ(LL): 0.064 J - -
S 1807 A A 11234 /612 A
HORZ(TL): 0.118 J - -
J 1471 A A /881 /401 A
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.924
B Big Width = 8.0 Min Req = 1.5
Max BC CSI: 0.826
S Brg Width = 8.0 Min Req = 2.1
Max Web CSI: 0.670
J Brg Width = - Min Req = -
Bearings B & S are a rigid surface.
Mfg Specked Camber.
Bearings B & S require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
A-B 44 0 E-F 1811 -2096
B - C 408 -386 F - G 2124 -2714
C - D 1469 - 2065 G - H 2677 -3609
D - E 1809 -2331 H -1 6 -33
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-S
93 -102
N-M
2122 -1431
R-Q
144 -163
M-L
2122 -1431
Q - P
2126 -1541
L - K
3086 -2302
P - O
2126 -1541
K - J
4418 -3555
O - N
1975 -1353
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
R - S
1343 -1737
N - F
276
-200
R - C
1343 -1702
F - L
65B
-412
C - Q
2096 -1449
L - G
822
-791
Q - D
535 -519
G - K
475
-142
D - O
247 -155
K - H
1202
-1148
O - E
307 -50
H - J
3710
-4590
E - N
372 -166
I - J
105
- 76
*"WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
s require extreme care in fabricatingg handlin ship Ing, installing,and bracing. Referto and follow the latest edition of BCSI (Building
vent Safety Information b TPI and'SBCA) for safe y practices poor to performing these functions. Installers shallprovide tempos
per BCSI. Unless noted oherwise,top chord shall have property attached structural shgathinpp and bottom chord shall have a properryly
d rigid ceiling Locations shown forpermanent lateral restraint of webs shall have bracmcLlnsialled per BCSI sections 83, 67 or B70, SCOSTA CORPORATION
cable. Apply plates to each face of truss and position as shown above and on the JoinCDeI ils, unless noted othervvise. f�efer to WOAD STEEL oR TIMBER
Is 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawl any failure to build the 3670 COMMERCE CENTER DRI)
conformance with ANSIWI 1, or for handling shiginq, installation and bracing of trusses.A seal on this drawing or cover pane sEBRING, FL 33870
this drawing, indicates acceptance of profess_ na`engrneertng. respo ^ ib)littr solelyfor the design show . The s r bility (663)385-8242
.�:
Job Number 91191 Ply:
/N&A CONSTRUCTION /JURADOICOD /KCD I W t 1250.E Ibs I FROM:26375 / T1 /HIPS I DRW.
Truss Label: A19 / ... 05/22/2020
19' 12'4-15/16"- -i 196-3116"
SEAT PLATE REQ. SEAT PLATE REQ.
i— 7'5-1/2" i
34'2-1/8"
�-z A_ 7'1" + 29'0-1/2• 5'6-1/8- 3-
a1'11-1/8"
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pf in PSE
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: N
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.19 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
:Rt Bearing Leg 2x4 SP #2:
Lumber value set 13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide hanger or special connection at right end of
truss for 1305 lbs.
N
1
Def11CSI Criteria
♦Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.122 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(TL): 0.227 F 999 240
B 366 /- A /244 /155 /395
HORZ(LL): 0.061 K - -
T 1611 /- /- /1114 1695 /-
HORZ(TL): 0.114 K - -
J 1305 /- /- /758 /403 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.683
B Big Width = 8.0 Min Req = 1.5
Max BC CSI: 0.634
T Big Width = 8.0 Min Req = 1.9
Max Web CSI: 0.781
J Brg Width = - Min Req = -
Bearings B &'T are a rigid surface.
Mfg Specified Camber.
Bearings B & T require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 1668 -1925
B - C 316 -339 F - G 1668 -1925
C - D 1491 -2069 G - H 1483 -1802
D - E 1551 -1949 H - I 1408 -1820
'"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
I P1 1, or for h
acceptance
any structure
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - T 57 -52 P - O 1737 -1203
S-R 51 -30 O-N 1615 -1096
R - Q 1870 -1352 N - L 1643 -1206
Q-P 1737 -1203 M-K 17 -4
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
S - T
1230 -1540
G - N
201
-44
S - C
1250 -1490
N - H
192
-149
C-R
1914-1381
H-L
314
-271
R- D
327 -209
L- M
108
0
D - Q
171 -202
L - K
62
-80
E- Q
306 - 7
L- I
1620
-1182
E- O
272 -237
J- K
97
0
F - O
437 -355
I - J
1569
-1489
O - G
429 -338
SCOSTA CORPORATION
ROO FbRTFLOOR TRUSSES
failure to build the 3670 COMMERCE CENTER DR])
g Or cover pege.SEBRI) 8,5 l z33870
r . The s r bilrty �3
Job Number: 91191 Ply: 1 SEQN: 26376 / T52 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A20 Wgt: 236.6 Ibs / ... 05/22/2020
1T 16'4-15/16" 96-3116' �{
SEAT PLATE REQ. SEAT PLATE REQ.
�-2' A_ TV
29'0-1/2"
41'11-1/9' —1
1
X5 b
Loading Criteria (psf Wind Criteria
Snow Criteria (Pg,PF in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in too Udell L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf. NA Ce: NA VERT(LL): 0.144 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.268 F 999 240
B 375 A A /281 /157 /357
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.077 J - -
R 1585 A A /1063 /687 /-
EXP: D
� Des Ld: 37.00 Mean Height:15.00 ft
ht:
Height:
HORZ 0.142 J - -
(rL):
J 1312 /- /- /748 /448 /-
NCBCLL: 10.00 TCDL:
Code / Misc Criteria Creep Factor: 2.0
Wind reactions based on MWFRS
Soffit: 0.00 BCDL: 6.0 psf
BldgCode: FBC 2017 RES Max TC CSI: 0.826
B Brg Width = 8.0 Min Req = 1.5
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
TPI Std: 2014 Max BC CSI: 0.938
R Brg Width = 8.0 Min Req = 1.9
J Big Width = - Min Req = -
Spacing: 24.0 " C&C Dist a: 4.19 ft
Rep Factors Used: Yes Max Web CSI: 0.760
Bearings B & R are a rigid surface.
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0) Mfg Specked Camber.
Bearings B & R require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
Value Set: 13B (Effective 6/1/2013)
A - B 44 0 E - F 1765 -2134
B - C 223 -269 F - G 1683 -2046
Top chord 2x4 SP #2
C - D 146 -163 G - H 1605 -1842
Bot chord 2x4 SP #2
D - E 1603 -2108 H -1 1457 -1868
Webs 2x4 SP #2
Lumber value set 1313" uses design values
Maximum Botns. Chord Forces Per Ply (Ibs)
approved 1/30/2013 by ALSC
Chords Tens.Comp. Chords Tens. Comp.
Loading
B-R 22 -17 N-M - 2284 -1674
Bottom chord checked for 10.00 psf non -concurrent
Q - P 1781 -1385 M - K 1704 -1231
live load.
P - O 1867 -1359 L - J 14 -8
O - N 2284 -1674
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
Maximum Web Forces Per Ply (Ibs)
BC @ 24" OC
Webs Tens.Comp. Webs Tens. Comp.
Wind
C - Q 341 -325 M - G 550 -272
Right end vertical not exposed to wind pressure.
Q - R 1220 -1515 G - K 175 -159
Q-D 1678 -2121 K-L 113 0
Additional Notes
D-P 235 -19 K-H 387 -229
Provide hanger or special connection at right end of
P - E 173 -6 K -1 1713 -1276
truss for 1312 Ibs.
E - O 430 -231 K- J 2 -6
O - F 341 -242 I - J 1070 -1255
F - M 439 -380
*`WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricatingp handlin shi mg, installing,and bracing.,Refer to and follow the latest edition of BCSI (Building
Safety Information b TPI and'SBCA) for satetpyr practices poor to pertormin these functioppe,BC
Installers shall provide tempora
BCSI. Unless noted oherwise,top chord shall have property attached st ctural sheathingg abottom chord shall have a proppeeryrly
id ceiling Locations shown forpermanent lateral restraint of webs shall have bracincLmstaS.Appllatertoeach tace,of trssand position as shown above and on the JoinCDetailunless noted otherwise. f�efer to
60A-Z for s�andard plate positions.
Of
any
ilure to build the 3670 COMMERCE CENTER
or cover qe SEBRING, FL 33870
. The s l Ability (663)365-8242
Job'Number. 91191 Ply: 1 SEQN: 26426 / T65 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A21 Wgt: 271.6 Ibs .. / ... 05/22/2020
15' 20'4-15/16" 6'6-3/16" —�
T12
5 C% 106XB D
T 4X50
T1
; ZN qqpp
A(A1) B W 4132
B1 AB 1113X6
SEAT PLATE REQ. SEAT PLATE REQ.
12X4 F5X6 11 4
= X6
=3X4 T3 �3X6_
Tq o5X6
E
=
M
i
012X4
W1
T5
W1
W1
W1
�6X1
W12
W12 W N %4X5
X B3 V
-
-6X8 W ro m
912X4 192X4
�
B5
�H0308-3X4
m3XP W15 W17 0
4 �
Q BB = O
EI2X4
F-2'—!—T1" i�T1"1-2'6"
41'11-1/6"
155-
59.5/8"--{
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
DefIJCSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT. NA
PP Deflection in loc Udell L/#
Gravity Non -Gravity
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): 0.301 H 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(rL): 0.563 H 746 240
B 331 /- /- /241 /127 /319
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.161 O - -
AB 1699 A A /1094 1742 /-
Des Ld: 37.00
EXP: D
HORZ : 0.299 O - -
�)
O 1294 P P /723 /492 /-
NCBCLL: 10.00
Mean Height:15.00 It
TCDL: 4.0 psf
Code / Mlsc Criteria
Code
Creep Factor: 2.0
reactions based on MWFRS
Soffit: 0.00
BCDL: 6.0
Bldg Code: FBC 2017 RES
Max TC CSI: 0.775
B Brg Width = 8.0 Min Req = 1.5
Load Duration:1.25
psf
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Max BC CSI: 0.809
AB Big Width = 8.0 Min Req = 2.0
O Brg Width = - Min Req = -
Spacing: 24.0 "
C&C Dist a: 4.19 It
Rep Factors Used: Yes
Max Web CSI: 0.803
Bearings B & AB are rigid surface.
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
Mfg Speed Camber.
Bearings B & AB require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS
VIEW Ver.18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 44 0 H -1 1942 -2405
Value Set: 13B (Effective 6/1/2013)
B - C 320 -336 I - J 2048 -25CA
Top chord 2x4 SP #2
C - D 1127 -1566 J - K 2048 -2564
Bot chord 2x4 SP #2
D - E 3272 -4310 K - L 1704 -2071
Webs 2x4 SP #2
E - F 3429 - 4331 L - M 1638 -1826
Lumber value set "13B"
uses design values
F - G 3196 - 4133 M - N 1466 -1845
approved 1/30/2013 by
ALSC
G - H 3168 -4095
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at right end of
truss for 1294 lbs.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B -AB
163 -198
U - T
2588 -1888
AA- Z
349 -451
T - S
258B -1888
Z-Y
56 -41
S-R
2447 -1811
X - V
3577 -2576
R - P
1664 -1227
W-U
44 -33
Q-O
19 -6
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
AA AB
1339 -1637
V - U
2948 -2105
AA- C
1331 -1588
H - U
1052 -1355
C - Z
1939 -1418
U -1
288 -352
Z-D
1050 -1287
I-S
121 -41
Z - X
1595 -1152
S - K
256 -22
D - X
2496 -1854
K - R
573 -646
E - X
302 -155
R - L
701 -433
X- Y
69 0
L- P
172 -207
X- F
972 -851
P- Q
113 0
F - V
907 -668
P - M
490 -251
G - V
152 -77
P - N
1694 -1279
V-W
32 0
P-O
0 -10
V - H
2O28 -1468
N - O
1067 -1235
"*WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling sh! Ing, installing bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety. Information by TPI and'SBCA) for safPe y practices pnor to performing these functions. Installers shall provide temporary
bracing per BCSI., Unless noted o herMse,top chord shall have property attached structural shgathinpp and bottom chord shall have a property
attached rigid ceilingg. Locai'lons shown forpermanent lateral restraint of webs shall have bracincLlnsZalled per BCSI sections B3, B7 or B10, SC TA CORPORATION
as applicable. Apply jlates to each face of truss and position as shown above and on the JoinfgDetails, unless noted otherwise. kefer to WOOD STEEL OR TIMBER
draA'ngs 160A Z for andard plate positions. ROOF bR FLOOR TRUSSES
Alpine, a division of ITW Buildin Components Group Inc, shall not be responsible for any deviation from this dravLigg any failure to build the 3670 COMMERCE CENTER DRIVE
truss in conformance with ANSIi 11, or for handlin ship In ,',nst@llafon and bracin of trusses. A seal on this drawnn or cover a e SEBRING, FL 33870
listingg this drawln� Indicates acceeptance of tgrd�essgnai en Ine... responsibilitvsolely for the desictl1n showt The seitgbility (863)385-8242
and ❑se of this cawing for any structure is a responsibillRof the uildifig Desigrier per ANSIfrP1IS ac.2.
Fnr mnrn Infnnna}inn euu fhic IrJJc ncnoral nn}a nano ann aace.uch a}a�- ni Dwc- - Wi n cwra ,.-.,,.. h•,•oafo nnn
Job Number. 91191
/N&A CONSTRUCTION /JURADO/COD /KCD
Truss Label: A22
r 13'
T 12 C
5 p
65X6 C
ro
1 T1
=3X8(A1) B W2
� A
P 81 O
/2X4 �3X4
SEAT PLATE REQ
E
Ply: 1 SEQN: 26378 / T14 / HIPS
Qty:1 FROM: DRW:
Wgt:225.4lbs .. / ... 05/22/2020
5/16"
#6-3/16"
Loading Criteria (psi)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
DefIJCSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: NA
PP Deflection in foe Udell U#
Gravity Non -Gravity
TCDL: 7.00
Speed: 159 mph
Pf. NA Ce: NA
VERT(LL): 0.230 M 999 360
Lee R+ / R- / Rh / Rw / U / RL
B 1698 A A /1139 /658 281
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.428 M 999 240
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.067 1 - -
1 1567 A A /787 /669 P
Des Ld: 37.00
EXP: DHORZ(TL):
0.124 I - -
Wind reactions based on MWFRS
Code / Misc Criteria
NCBCLL: 10.00
Mean Height: 15.00 ft
TCDL: 4.0 psf
Creep Factor: 2.0
B Borg Width = 8.0 Min Req = 1.5
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.962
I B Width = - Min Re q = -
� Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Max BC CSI: 0.446
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Spacing: 24.0 "
C&C Dist a: 4.19 ft
Rep Factors Used: Yes
Max Web CSI: 0.905
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
Mfg Specked Camber.
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18
Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01A.0205.19
A- B 44 0 E - F 2275 -28W
B - C 2358 - 3375 F - G 1564 -1932
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 136 (Effective
6/1/2013)
C - D 2373 -3178 G - H 113 -65D
- E 2287 -2871
Top chord 2x4 SP #2 :T4 2x4 SP M31:
Bot chord 2x4 M-31
Webs 2x4 SP #2
mum Forces MaxiBot Chord FP
Ply (Ibs)
)
Chords
Tens.Comp.
Chords
Tens. Comp.
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
B - P
3070 -2332
M - L
3032 -2298
P - O
3132 -2499
L - K
2585 -1978
Bracing
O - N
2583 - 2009
K - J
2585 -1978
(a) 2x4 #3 or better "T' reinforcement. 80% length of
N - M
2583 - 2009
J -1
1139 -891
web member. Attach with 16d Box or Gun
(0.135"x3.5",min.)nails @ 6" OC.
Maximum Web Forces
Per Ply (Ibs)
Loading
Webs
Tens.Comp.
Webs
Tens. Comp.
Bottom chord checked for 10.00 psf non -concurrent
P - C
277 -86
L - F
471 -210
live load.
C - O
431 -329
F - J
980 -1093
O - D
491 -230
J - G
1326 -839
Purlins
D - M
485 -217
G -1
1382 -1764
In lieu of rigid ceiling provide lateral bracing to brace
M - E
347 -271
H -1
235 -135
BC @ 24" OC
E - L
326 -278
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at right end of
truss for 1567 lbs.
-WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
*IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
inWmponents Group Inc. shall not be responsible for any deviation from this drawing any failure to build the
31�1 1, or for handlin ship In , installation and bracing of trusses.A seal on this tlratnnngg or cover page
�s acceptance of prdfessi8na� en lneennq respon Nbility solelyfor the design showfi. The suitability
or any structure is the responsibilit' of the Building Designer per ANSI/TPI 1 Sg .2.
neml notes oaae and these weh ates AI PINF• www alninzitw r TPI• www tni—I — SRrA• www shrind—f onm• IM, www Inca
SCOSTA CORPORATION
ROOF FR FLOOR TRUSSES
3670 COMMERCE CENTER DRI1
SEBRING, FL 33870
(863)385-8242
Job Number: 91191 Ply: 2 SEQN: 26410 / T2 / HIPM
/N&A CONSTRUCTION /JURADO/COD /KCD i ' Qty: 1 FROM: DRW:
Truss Label: Al Wgt: 663.6 Ibs .. / ... 05/22/2020
2 Complete Trusses Required
7- 'f' 39,
12 !08X8 =@10X10 =-10X10 =10X10
5 p C T2 D T2 E F T3 = G
B
= A
Loading Criteria (pst)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
N M L K J
5X6=H1010 B2=3X4=H10107=3X8
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 4.60 ft
Loc. from endwall: NA
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set:13B (Effective 6/1/2013)
Top chord 2x8 SP 2400f-2.0E :T1 2x4 SP #2:
Bot chord 2x8 SP 2400f-2.0E
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Nailnote
Nail Schedule:0.149W.26% min. nails
Top Chord:1 Row @12.00" o.c.
Bot Chord: 1 Row @12.00" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Loading
#1 hip supports 7-0-0 jacks with no webs.
Left side jacks have 7-0-0 setback with 0-0-0 cant
and 2-0-0 overhang. End jacks have 7-0-0 setback
with 0-0-0 cant and 2-0-0 overhang. Right side jacks
have 0-0-0 setback with 0-0-0 cant and 0-0-0
overhang.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
46
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in too Udell L/#
PF. NA Ce: NA
VERT(LL): 0.481 L 999 360
Lu: NA Cs: NA
VERT(TL): 0.914 L 602 240
Snow Duration: NA
HORZ(LL): 0.073 H - -
HORZ(TL): 0.139 H - -
Code / Misc Criteria
Creep Factor: 2.0
Bldg Code: FBC 2017 RES
Max TC CSI: 0.638
TPI Sid: 2014
Max BC CSI: 0.382
Rep Factors Used: No
Max Web CSI: 0.787
FT/RT:20(0)/10(0)
Mfg Specked Camber.
Plate Type(s):
WAVE, HS
I VIEW Ver. 18.02.01A.
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 3585 lbs.
0205.19
"'WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
any
T�
W W3
�=c
=5X10 m5X14
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
P 3555 /- /-
A /2045 /-
H 3585 A A
A /1998 A
Wind reactions based on MWFRS
P Big Width = 8.0
Min Req = 1.5
H Brg Width = -
Min Req = -
Bearing P is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A - B 22 -22
D - E 4117 - 7590
B - C 2364 -4286
E - F 3607 -6670
C - D 3116 - 58M
F - G 1494 -2902
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - O 3953 -2170 L - K 7598 -4334
O - N 3810 -2152 K - J 7598 -4334
N - M 7255 -4171 J -1 5340 -3115
M - L 7255 -4171 I - H 10 -8--
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
O - C
225 -28
E - J
828 -1058
C - N
2283 -1103
J - F
1516 -561
N - D
1206 -1658
F - I
1848 -2779
D- L
9V 0
I- G
3253 -1672
L - E
247 -9
G - H
1003 -1734
SCOSTA CORPORATION
ROD RLRRUS�OFPFOOTRSES
failure to build the 3670 COMMERCE CENTER DRI1
or cover e, , SEBRING, FL 33870
119. The s i bdrty (863)385.8242
Job Number. 91191
Ply: 1
SEQN: 26359 / T68 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD
Qty: 1
FROM:
DRW:
Truss label: A2
Wgt: 254.8 Ibs
/ ... 05/22/2020
�— 9'
36'5-1/4'
6 „
12 D=
T2 E 6
T2 FX6 T2 G 6 T3
5
O.2X4 —
T1 C
=6X6H
T T
m
W3
W3
W3
(a) (a) ZZ
W4 'v
=3X8(A1) B
l
O N M L K
B2
83 J I 1
m4X4
C
=H0510
=3X4=H0510=3X5
--5X6
SEAT PLATE REQ.
46'
Loading Criteria (pst) Wind Criteria
Snow Criteria (Pg,Pf in PsF)
Defl/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): 0.471 M 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.875 M 628 240
B 1851 /- P /1172 /1096 /285
BCDL: 10.00 Risk Category: II
Snow Duration: NA
HORZ(LL): 0.111 1 - -
1 1720 P P /840 1985 /-
EXP: D
Des Ld: 37.00
HORZ(Tt•) : 0.207 1 - -
Wind reactions based on MWFRS
NCBCLL: 10.00 Mean Height:15.00 ft
Code / Misc Criteria
Creep Factor: 2.0
B Big Width = 8.0 Min Req = 1.5
TCDL: 4.0 psf
Soffit: 0.00 BCDL: 6.0 sf
p
Bldg Code: FBC 2017 RES
Max TC CSI: 0.780
1 Brg Width = - Min Req = -
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h
TPI Sid: 2014
Max BC CSI: 0.578
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Spacing: 24.0 " C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Max Web CSI: 0.891
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 6.50 ft
FT/RT:20(0)/10(0)
Mfg Speed Camber.
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
VIEW Ver.18.02.01A.0205.19
A- B 44 0 E - F 3838 -5272
Lumber
B - C 2827 -3804 F - G 3259 -4513
C - D 2765 - 3676 G - H 1402 -2006
Value Set: 136 (Effective 6/1I2013)
D - E 3209 -4312
Top chord 2x6 SP #2 :T1 2x4 SP #2:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2 :W4 2x6 SP #2:
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.
Tens.Comp. Chords Tens. Comp.
Lumber value set " 13B" uses design values
approved 1/30/2013 by ALSC
B - P 3451 -2808 M - L 5187 -3896
P - O 3286 - 2602 L - K 5187 -3896
Bracing
O-N 5132 -3923 K-J 3608 -2760
(a) 1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
N - M 5132 - 3923 J -1 42 -47
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ 6' OC.
Maximum Web Forces Per Ply (Ibs)
Loading
Webs Tens.Comp. Webs Tens. Comp.
Bottom chord checked for 10.00 psf non -concurrent
C - P 250 -117 F - K 820 -868
live load.
P - D 271 -90 K - G 1166 -643
D - O 1326 -824 G - J 1750 -2064
Purlins
O-E 958 -1057 J-H 2443 -1685
In lieu of rigid ceiling provide lateral bracing to brace
E - M 329 -88 H -1 1281 -1684
BC @ 24" OC
M - F 268 -51
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1720 lbs.
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWNGI
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating he dlin ,ship ang, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
Corrtponent Safety Information b TPI and SBCA) for safe y practices pnor to performing these functions. Installers shall provide tempora
bracing per BCSI. Unless noted o�herwise,top chord shall have property attached structural sheathanp and bottom chord shall have a proppeerryly
attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin(,� nslailed per BCSI sections B3, B7 or 510, SCOSTA CORPORATION
as applicable. Apply plates to each face, of truss and position as shown above and on the JoinfDetailS, unless noted otherwise. kefer to WOOD STEEL OR TIMBER
drawings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Alpine, a division of ITW BuiidinlComponents Group Inc. shall not be responsible for any deviation from this drawing any failure to build the 3670 COMMERCE CENTER DRIVE
truss in conformance with ANSI PI 1, or for handling shi�ging, installation and bracing of trusses A seal on this yawing or cover page_ , SEBRING, FL 33870
listing this drawing indicates acceptance of pr ress na engineering respon ability soleiyfor the desiggn shown. The sUi bility (863)385-8242
and Ease of this drawing for any structure is the responsibility of the guildiiig Designer per ANSIITPI 1 S€c.2.
Job Number. 91191 Ply: 1 SEQN: 26360 / T70 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A3 Wgt: 2352 Ibs / ... 05/22/2020
2-6-3/4-1
-D 6 @E 6 @FX6
@G
6 @H 6
12
T3
5
11112X4 T
T1
W
%40
(a) io
3X8(A1) B
W3 W3
W7
W3
W3 in
W4 6
o,
A
_
61
Q P 0— B2 N
M L
B2 K — J
=3X4 =H0308 =3X4
�H0308=3X4
m4X6
SEAT PLATE REQ
,
c
46'
-�
�-2'-�
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Lc[- 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: .0 psf
Bldg Code: FBC 2017 RES
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
TPI Std: 2014
Spacing: 24.0 "
C$C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 It
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP M31 :T1, T3 2x4 SP #2:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumbervalue set "13B" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1720 lbs.
Defl/CSI Criteria
PP Deflection in too Udefl U#
VERT(LL): 0.352 N 999 360
VERT(TL): 0.653 N 842 240
HORZ(LL): 0.096 J - -
HORZ(TL): 0.178 J - -
Creep Factor: 2.0
Max TC CSI: 0.750
Max BC CSI: 0.482
Max Web CSI: 0.850
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
of
'Ivi 1,or Torn
acceptance
any structure
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1851 /- A 11204 /1097 /272
J 1720 A A 1843 /1015 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Big Width = - Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 3203 -4241
B - C 2906 -3833 F - G 2807 -3705
C - D 2640 -3558 G - H 1589 -2069
D - E 2867 -3709 H -1 60 -35
Maximum Bat Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - Q 3489 -2852 N - M 4161 -3129
Q - P 3109 -2424 M - L 4161 -3129
P - O 3109 -2424 L - K 3108 -2373
O - N 4176 -3172 K - J 889 -694
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
C - Q
440 -288
F - L
637 -692
Q-D
367 -78
L-G
907 -510
D - O
910 -566
G - K
1338 -1575
O - E
652 - 708
K - H
1789 -1208
E - N
218 - 72
H - J
1426 -1820
N - F
225 -42
I - J
128 - 76
SCOSTA CORPORRATTryIgON
ROOF bVP OOR TRUSSES
failure to build the 3670 COMMERCE CENTER DRB
i or cover pa e, SEBRING, FL 33870
I . The sU blhty (863)385-8242
Job Number. 91191 Ply: 1 I SEQN: 26361 / T69 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A4 I Wgt: 2422 Ibs .. / ... 05/22/2020
—13' i28'5-114"
4'6-3/4" ---{
02D T3 6 E 6 T3 F 6 T3 Ge
T4 12 T2
T
S p I
W W W W H 1112X4 T
m jo5X6 C ( a) W
ro
T1 W4 W4 W3 ZZ
Z
W2 W5 d f6
A _
P B1 O N M B2 L K — I
/2X4 =3X4 =1-10308 m3X4 =3X4 =H0308 B2
SEAT PLATE REQ.
� 46' '
�— 2'
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT. NA
PP Deflection in loc Udef L/#
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): 0.286 E 999 360
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.531 E 999 240
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.085 1 - -
Des LC:37.00
EXP: D
Height:
Mean Height:15.00 ft
HORZ(TL): 0.158 I - -
NCBCLL: 10.00
TCDL: 4.0
Code / Misc Criteria
Creep Factor: 2.0
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.794
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Sid: 2014
Max BC CSI: 0.544
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Max Web CSI: 0.987
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
Mfg Specked Camber.
GCpi: 0.18
Plate Type(s):
VIEW Ver. 18.02.01A.0205.19
Wind Duration:1.60
WAVE, HS
Lumber Additional Notes
Value Set: 13B (Effective 6/1/2013) WARNING: Furnish a copy of this DWG to the
Top chord 2x4 SP #2 :T3 2x4 SP M31: installation contractor. Special care must be taken
Bot chord 2x4 SP M-31 during handling, shipping and installation of trusses.
Webs 2x4 SP #2 See "WARNING" note below.
Lumber value set "139" uses design values Provide hanger or special connection at right end of
approved 1/30/2013 by ALSC truss for 1720 lbs.
Bracing
(a)1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ G' OC.
(b) 2x4 #3 or better'T' reinforcement. 80% length of
web member. Attach with 16d Box or Gun
(0.135"x3.5",min.)nails @ 6' OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
'"'WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
11 Pl 1, or for h
acceptance
any sructure
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1848 A A /1231 1715 1284
1 1720 /- A /870 /74D A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
1 Brig Width = - Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 2722 -3482
B - C 2671 -3739 F - G 1828 -2300
C-D 2710 -3572 G-H 114 -68
D - E 2660 -3384
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - P 3394 -26M M - L 3659 -2777
P - O 3433 -2721 L - K 3144 -2411
O - N 2943 -2290 K - J 3144 -2411
N - M 2943 -2290 J -1 1275 -1002
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
P-C
2D4 -58
L-F
539 -210
C - O
388 -280
F - J
1157 -1288
O - D
505 -264
J - G
1562 -991
D - M
673 -334
G -1
1548 -1962
M - E
487 -420
H -1
237 -138
E - L
357 -271
ms 63,137 or 131 u; —
SCOSTA CORPORATION
Ierwise. fierier to
WOOD STEEL OR TIMBER
ROOF bR FLOOR TRUSSES
failure to build the
3670 COMMERCE CENTER DRI\
i or cover e_ ,
SEBRING, FL 33870
19. The s I blllty,
(863)385-8242
Job Number. 91191 Ply: 1 I SEQN: 26362 / T56 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A5 I Wgt: 253.4 Ibs .. / ... 05/22/2020
16
zx-5X6
D
SEAT PLATE REQ.
46'
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Lc: 37.00
Mean Height:15.00 It
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 it
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 it
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/112013)
Top chord 2x4 SP 92 :T2 2x4 SP M31:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 byALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ G' OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1720 lbs.
a
2V5-1/4" -i V6-3/4
$5X6
G
H " 4X6
io
m
W6 M
11
Deft/CSI Criteria
♦Maximum Reactions (ibs)
PP Deflection in loc Udefl U#
Gravity Non -Gravity
VERT(LL): 0.257 N 999 360
Loc R+ / R- / Rh / Rw / U / RL
B 1848 /- /- /1253 /711 /323
VERT(I-Q: 0.478 N 999 240
HORZ(LL): 0.0771 - -
1 1720 /- /- /893 /681 /-
HORZ(TL): 0.143 1 - -
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.900
1 Brg Width = - Min Req = -
Max BC CSI: 0.441
Bearing B is a rigid surface.
Max Web CSI: 0.961
Bearing B requires a seat plate.
Mfg Specified Camber.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01A.0205.19
A- B 44 0 E - F 2428 -3019
B - C 2644 -3799 F - G 1846 -2220
C - D 2504 -3316 G - H 966 -1225
D - E 2448 -3018
*'WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING I
quire extreme care in fabricating, handling, shipping, installing and bracing. Refer to ani
any
siramr or wens snau nave DT,.n rnsraueD per u
as shown above and on the Jain etaiIs. unless
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - Q
3447 -2572
M - L
2767 -2083
Q - P
3404 -2697
L - K
2767 -2083
P - O
2778 -2118
K - J
1570 -1203
O-N
2778 -2118
J-1
12 -20
N - M
3163 - 2372
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
Q- C
260 0
M- F
468 -207
C - P
553 -486
F - K
865 -1006
P - D
494 -224
K - G
1195 -753
D - N
442 -225
G - J
957 -1104
N - E
337 -265
J - H
1533 -1087
E - M
326 -265
H -1
1374 -1700
of BCSI (Building
nvide tempora
ill have a Is 63, B7pro
B110,
or
rwise. kefer to
SCOSTA CORPORATION
WOOD STEEL OR TIMBER
ROOF bR FLOOR TRUSSES
iilure to build the
3670 COMMERCE CENTER DRIVE
Or cover e
SEBRING, FL 33870
The s i bility
(863)385-8242
IJob Number 91191 Ply:
Truss Label: AUCTION /JURADO/COD /KCD I W t '239.4 Ibs FROM; 26363 / T76 /HIPS DRW% 05/22/2020
r 17'
i 20'5-1/4" }+
96-3/4" -{
aE 6 F 4 G5 6 T4 8 HX6
12
2
T2
1112X4D W
W W W
T5
O T
S
a)
W5 W5 W5
W4 I Q4X6
Q5X6C
T
T1
W7
-4i-g o
W1
W2
Q B2
P O B3 N M L 83
K M3 6JT
=3AX5(A1) B
5X6
=H0308 -3X4 =3X4 =3X6 =3X4
=4X4
zu
Bt
=6X6
IS;4
SEAT PLATE REQ.
SEAT PLATE REQ
SEAT PLATE REQ.
k 12'4"
33'8"
1-2 +i 12'31/2"
46
Loading Criteria (psQ Wind Criteria
Snow Criteria (Pg,PF in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in loc Udell L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA VERT(LL): 0.102 G 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.189 G 999 240
B 556 /- A /426 /176 P362
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.027 J - -
R 1762 A /- /1139 /744 A
EXP: D
Des
HORZrn) 0.054 J - -
T 1267 A /- /770 /433 A
.00 Mean Height: 15.00 ft
NCBCLL: 1100.00
Code / Misc Criteria Creep Factor: 2.0
Wind reactions based on MWFRS
TCDL: 4.0 sf
Soffit: 0.00 P
Bldg Code: FBC 2017 RES Max TC CSI: 0.705
B Brg Width = 8.0 Min Req = 1.5
BCDL: 6.0 psf
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
TPI Std: 2014 Max BC CSI: 0.822
R Big Width = 8.0 Min Req = 2.1
T Brg Width = 8.0 Min Req 1.5
Spacing: 24.0 " C&C Dist a: 4.60 it
Rep Factors Used: Yes Max Web CSI: 0.925
Bearings B, R, & T are rigid surface.
Loc. from endwall: not in 13.00 ft
FT/RT:20 /10 Mfg Specified Camber.
0 0
() () 9 P
Bearings B, R, & T require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A- B 44 0 E - F 1-1520
Value Set: 13B (Effective 6/1/2013)
B - C 228 -585 F - G 1695 695 -20422042
Top chord 2x4 SP M-31 :T1, T2 2x4 SP #2:
C - D 223 -173 G - H 1613 -1914
Bot chord 2x4 SP #2
D - E 179 -97 H -1 1079 -1484
Webs 2x4 SP #2
Lumber value set "13B" uses design values
Maximum Bot Chord Forces Per Ply (Ibs)
approved 1/30/2013 by ALSC
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B-S 486 -312 N-M 2091 -1501
(a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80%
S - R 481 -315 M - L 2091 -1501
length of web member. Attach with 8d Box or Gun
Q - P 1024 -721 L - K 1630 -1222
(0.113"x2.5",min.)nails @ 5' OC.
P - O 1022 -721 K - J 49 -79
O - N 1914 -1371
Loading
Bottom chord checked for 10.00 psf non -concurrent
Maximum Web Forces Per Ply (Ibs)
live load.
Webs Tens.Comp. Webs Tens. Comp.
Purlins
S-C 276 0 F-N 264 -86
In lieu of rigid ceiling provide lateral bracing to brace
C - R 406 -583 N - G 171 -91
BC @ 24" OC
R - Q 1185 -1463 G - L 324 -321
D-Q 432 -284 L-H 514 -211
Additional Notes
Q - E 1103 -1544 H - K 543 -494
WARNING: Fumish a copy of this DWG to the
E - O 902 -533 K -1 1343 -841
installation contractor. Special care must be taken
O - F 675 -717 I - J 1015 -1248
during handling, shipping and installation of trusses.
See "WARNING" note below.
Of
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
4T** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
care in fabricating handlin sh! rng, installing ,and bracing. Refer to and follow the latest edition of BCSI (Building
mation b TPI and fabricating,
toy sate y practices pnor to performing these functions. Installers shall provide temporary
s noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proppeerty
xations shown for permanent lateral restraint of webs shall have bracinccLLinstalled per BCSI sections 63, 87 or B10, SCOSTA CORPORATION
ates to each face of truss and position as shown above and on the JoinfDetails, unless noted otherwise. f�efer to WOOD STEEL OR TIMBER
ndard plate positions. ROOF A FLOOR TRUSSES
any
failure to build the 3670 COMMERCE CENTER DW
ih�rTheesUit2e,flty SEB�RI3) F82 870
IJob Number. 91191 Ply: 1 SEQN: 26364 / T72 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Oty: 1 FROM: DRW.
Truss Label: A7 Wgt: 247.8 Ibs / ... 05/22/2020
rt , 19 -i 195-1/4"
10'6-3/4" -�
obw =bus -Mbxu
E T3 F T3 G
12 T2 W W W T4
5 p �3X6D e3X6
M WB W6 W5 IN
tD 5X6 W3 W4
yC
W9
T1
W1 W2 Q �-JAD O NM B3 M L K B3 =6 JT
=3A (A1) B 3X4 (al =H0308 =3X4 =3X6 =3X4
B1 S =6X6 JJ
IM
SEAT PLATE REQ.
—1 z4"
2 + 12n-10
SEAT PLATE REQ.
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BOLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category:11
EXP: D
Des Ld: 37.00
Mean Height:15.00 it
NCBCLL: 10.00
TCDL: 4.0 psf
Soffit:' 0.00
BCDL:6.0psf
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Loc. from endwall: not in 13.00 it
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/112013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "13131" uses design values
approved 1/3012013 byALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
46'
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/l0(0)
Plate Type(s):
WAVE, HS
33'8"
33'8-1/Z'
Deff/CSI Criteria
PP Deflection in too Udell L/#
VERT(LL): 0.091 F 999 360
VERT(TL): 0.170 F 999 240
HORZ(LL): 0.023 J - -
HORZ(TL): 0.045 J - -
Creep Factor: 2.0
Max TC CSI: 0.780
Max BC CSI: 0.799
Max Web CSI: 0.678
Mfg Specked Camber.
VIEW Ver: 18.02.01A.0205.19
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Of
SEAT PLATE REQ.
f
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 549 /- /-
/398 /176 /401
R 1788 A A
11195 /753 /-
T 1260 A A
1792 1386 A
Wind reactions based on MWFRS
B Big Width = 8.0
Min Req = 1.5
R Brg Width = 8.0
Min Req = 2.1
T Big Width = 8.0
Min Req = 1.5
Bearings B, R, & Tare a rigid surface.
Bearings B, R, & T require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
E- F 1334 -1522
B - C 178 -569
F - G 1501 -1730
C - D 293 -232
G - H 1408 -1772
D - E 855 -1029
H -1 60 -49
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - S
472 -258
N - M
1789 -1264
S - R
467 -260
M - L
1570 -1110
Q-P
52 -59
L-K
1570 -1110
P - O
1146 -782
K - J
1355 -1088
O - N
1146 -782
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
S- C
276 0
N- F
507
-474
C-R
391 -688
F-M
221
-104
R - Q
1204 -1494
M - G
299
-117
Q - D
1218 -1454
G - K
159
-29
D-P
1175 -754
K-H
320
-85
P - E
569 -645
H - J
1428
-1739
E - N
667 -392
I - J
124
-72
u n is ceum . Locations snown Tor ermanent imeral restraint or wens snan nave oraanc ristaneo per bL;sl sections tss, tsr or ts1u, SCOSTA CORPORATION
Ica e. App y plates to each face o truss and position as shown above and on the JoinfgDetails, unless noted otherwise. Refer to WOOD STEEL OR TIMBER
s 160A Z for standard plate positions. ROOF bR FLOOR TRUSSES
a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drav�in9 any failure to build the 3670 COMMERCE CENTER DRn
conformance with ANSIPI1, orfor handlin shippin ,installation and bracinn of trusses.A seal on this gravnnrt or cover page, SEBRING, FL 33870
this drawing, indicates acceptance of efessppna� en meenn responsibilit�yy solely for the design shoWh. The spi Qbrlity (863)365.8242
;e of this �favving for any structure is tTre responsibilit.pof the B9uildirsg Desigrfer per ANSI/TPI 1 S�c.2.
Job Number: 91191 Ply: 1 SEQN: 26365 / T66 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD City: 1 FROM: DRW:
Truss Label: AS Wgt: 249.2 Ibs .. / ... 05/22/2020
21' 12'5-1/4" 12'63/4"
160AU IOLX4 -0A6
E F G
12 O W yy7 W T4
5 I% o03X6D H\3X8
W6 W5
/5X6c W3 W4
W7
T1
W1 W2 P B2 O N J� L K 83 =g g JS
=3AX5(A1) B 3X4 =3X5 =H0308 (aal =3X6 =3X4
B1 R 6X6 �J
III�Y1
SEAT PLATE REQ. SEAT PLATE REQ.
i 124" i —
1
2X4 T
0 1'10.3n6'
�1
SEAT PLATE REQ.
f- 2' 1 12'3-1/2" i 338-1/2" - I
46'
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pt in PSF)
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 It
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP M-31 :B1 2x4 SP #2:
Webs 2x4 SP #2
Lumber value set "'I 3B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Defl/CSI Criteria
PP Deflection in too Udefl U#
VERT(LL): 0.076 F 999 360
VERT(TL): 0.142 F 999 240
HORZ(LL): 0.015 J - -
HORZ(TL): 0.031 J - -
Creep Factor: 2.0
Max TC CSI: 0.878
Max BC CSI: 0.450
Max Web CSI: 0.923
Mfg Specked Camber.
VIEW Ver: 18.02.01A.0205.19
AL Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 549 /- /-
/376 A SO /440
Q 1796 /- /-
/1235 /748 /-
S 1258 /- /-
/809 )384 /-
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
Q Brg Width = 8.0
Min Req = 2.1
S Brg Width = 8.0
Min Req = 1.5
Bearings B, Q, & S are a rigid surface.
Bearings B, Q, & S require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
E- F 1409 -1566
B - C 160 -566
F - G 1409 -15W
C - D 338 -282
G - H 1380 -1768
D - E 933 -1194
H -1 67 -53
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - R 469 -225 N - M 1203 -809
R - Q 464 -227 M - L 1486 -1019
P-O 37 -41 L-K 1486 -1019
O - N 1203 -809 K - J 1452 -1153
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
R- C
276 0
F- M
360
-300
C - Q
343 -580
M - G
213
-117
Q-P
1216-1518
G-K
301
-20
P - D
1235 -1473
K - H
258
-70
D - O
1198 -727
H - J
1470
-1804
O-E
498 -451
I-J
136
-73
E - M
542 -357
*"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fMI
ating handlin shippping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building
'iSafety Information b and SBCA) toy safely practices pnor to performing thesefunctions. Installers shall provide temposBCSI.Unless noted ovise,top chord shall have properi attached structural sheathm and bottomchord shall have apro id ceilingg Locationsn forpermanent lateral restraint of webs shall have bracincLlnjailed per BCSI sections B3, 67 or �10, SCOSTA CORPORATION
e, gppiy plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. f�efer to WOOD STEEL OR TIMBER
60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
a division of
'l F 11, or for h
acceptance
any structure
failure to build the 3670 COMMERCE CENTER DRII
or covet e. • SEBRING, FL 33870
/ . The s i blllty (863)385-8242
Job Number. 91191 Ply: 1 SEQN: 26366 / T75 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A9 Wgt: 253A Ibs / ... 05/22/2020
23' 8'51/4" 14'63/4"
90oxa m5xa
F T3 G
T2
%3X4
5 12 /4X4
E W H T4
p (a) (a)
/5X6� W W7 W6 W
T7 /3X4 W5 VY9 1 %0
C W
W11
W1 W2 O B2 P O M L B3 K I3 JT
A6(A1)8 5X6 =3X4 =H0308 83 =3X6=3X4 =4X4
131 S 6
MWA
SEATPLATEREQ. SEAT PLATE REQ.
i 1z4" i-
SEAT PLATE REQ.
33'8"
2' 1 12'3-1/2" i338.1/2'
M,
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pt in psF) Defl/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in too L/defl L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA VERT(LL): 0.074 G 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(rL): 0.137 G 999 240
B 561 /- /- /383 /197 /479
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.021 J - -
R 1754 /- P /1229 /701 P
Des Ld: 37.00 EXP: D
HORZ(TL): 0.043 J - -
T 1269 /- /- /819 1384 /-
NCBCLL: 10.00 Mean Height:15.00 ft
Code / Mist: Criteria Creep Factor: 2.0
Wind reactions based on MWFRS
TCDL: 4.0 psf
Soffit: 0.00 BCDL: 6.0 psf
p
ode: FBC 2017 RES Max TC CSI: 0.812
BldgC
B B Width = 8.0 Min Re 1.5
q =
Load Duration: 1.25 MWFRS Parallel Dist: h to 2h
TPI Sid: 2014 Max BC CSI: 0.757
R Brg Width = 8.0 Min Req = 2.1
T Brg Width = 8.0 Min Req = 1.5
Spacing: 24.0 " C&C Dist a: 4.60 It
Rep Factors Used: Yes Max Web CSI: 0.921
Bearings B, R, & Tare a rigid surface.
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0) Mfg Specked Camber.
Bearings B, R, & T require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver.18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 44 0 E - F 1147 -1336
Value Set: 13B (Effective 6/1/2013)
B - C 246 -598 F - G 1296 -1373
Top chord 2x4 SP #2
C - D 338 -296 G - H 1447 -1740
Bot chord 2x4 SP #2
D - E 307 -238 H -1 1101 -1514
Webs 2x4 SP #2
Lumber value set "1313" uses design values
Maximum Bot Chord Forces Per Ply (Ibs)
approved 1/30/2013 by ALSC
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B - S 499 -345 N - M 1408 -935
(a)1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80%
S - R 494 -347 M - L 1408 -935
length of web member. Attach with 8d Box or Gun
Q - P 914 -671 L - K 1628 -1194
(0.113"x2.5",min.)nails @ G' OC.
P - O 1252 -829 K - J 33 -56
O - N 1252 -829
Loading
Bottom chord checked for 10.00 psf non -concurrent
Maximum Web Forces Per Ply (Ibs)
live load.
Webs Tens.Comp. Webs Tens. Comp.
Purlins
S- C 275 0 F- N 329 -118
In lieu of rigid ceiling provide lateral bracing to brace
C - R 438 -591 N - G 223 -157
BC @ 24" OC
R - Q 1092 -1447 G - L 342 -159
D - Q 283 -224 L - H 317 -209
Additional Notes
Q - E 1125 -1507 H - K 516 -499
WARNING: Furnish a copy of this DWG to the
E - P 425 -124 K -1 1409 -930
installation contractor. Special care must be taken
P - F 234 -207 I - J 996 -1242
during handling, shipping and installation of trusses
See "WARNING" note below.
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricating handlin ,ship rng, installing,and bracing. Referto and followthe latest edition of BCSI (Building
Safety Information b�r TPI and SBCA) for safe y practices poor to performing t�ese functions. Installers shall provide temporary
BCSI. Unless noted o herwlse,top chord shall have propedy attached structure sheathinand bottom chord shall have a properly
Id ceiling Locations shown for permanent lateral restraint of webs shall have bracing In Iled per BCSI sections B3, 67 or 10, SCOSTASCOSTA CORPO4
5e. Apply plates to each face, of truss and position as shown above and on the Jointi Details, unless noted otherwise. f7efer to WOOD STEEL oR TIMBER
60A Z for andard plate positrons. ROOF bR FLOOR TRUSSES
of
I NI 1, or for h
acceptance
any structure
failure to build the 3670 COMMERCE CENTER DRI\
1%pp Or cover ppa a SEBRING, FL 33870
. The sU1 billty (863)385-8242
Job Number. 91191 Ply:1 SECIM 26367 / T10 / SPEC
/N&A CONSTRUCTION MURADO/COD /KCD Qly: 1 FROM: DRW:
Truss Label: A10 Wgt: 285.6 Ibs .. / ... 05122/2020
24'6-12" 141w5/tfi ro-5/16. 1 14'1-5/16" �
SEAT PLATE RE4. SEAT PLATE REM
---12'4" --i
1-7 +1 173-12" i 33'8-12"
46'
Loading Criteria (psf)
Wind Criteria
Snow Criteria ft,Pf in PSF)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: N/
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.09 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: IT to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set:13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Sot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set 1313" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live Iced.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.101 H 999 360
VERT(TL): 0.188 H 999 240
HORZ(LL): 0.016 L - -
HORZ(TL): 0.033 L - -
Creep Factor: 2.0
Max TC CSI: 0.831
Max BC CSI: 0.746
Max Web CSI: 0.804
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
SEAT PLATE REG.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 553 /- /-
1355 /198 1510
U 1779 /- A
/1261 /646 /-
W 1262 A /-
/815 /376 A
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
U Brg Width = 8.0
Min Req = 2.1
W Brg Width = 8.0
Min Req = 1.5
Bearings B, U, & W are
a rigid surface.
Bearings B, U, & W require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A-B 44 0
F-G 1294 -1217
B - C 229 -579
G - H 1372 -1356
C - D 406 -350
H -1 1399 -1422
D - E 1058 -1269
I - J 1395 -1617
E - F 1291 -1385
J - K 1405 -1835
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-V
482 -295
Q-13
1217 -775
V - U
4T7 -298
P - O
1408 -959
T-S
37 -41
O-N
1647 -1204
S - R
1135 -780
N - M
1647 -1204
R-Q
1135 -780
M-L
48 -57
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
V- C
275 0
G- P
623 -691
C - U
421 -595
P - H
802 -773
U - T
1138 -1479
H - O
190 -155
T-D
1162 -1419
0-1
347 -175
D - S
1293 -897
0- J
321 -329
S - E
511 -477
J - M
351 -206
E - Q
251 -87
M - K
1628 -1178
F - Q
210 -78
K - L
1032 -1202
"'WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating IT dlin sh! Lng, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information b TPI end SBCA) fo' sateiy practices pnor to performing these functions Installers shall provide temporary
braaggXer SCSI Unless noted o�hermse,top chord shall have property attached structural sheattlinq and bottom chord shall �ave a progeny �
attac a r!99id ceifing. Locations shown forpermanent lateral restraint of webs shall have bracincLins alied per BCSI sections 3, B7 or I .
asap livable. Apply fates to each face of truss and position as shown above and on the Joint -Details, unless noted otherwise. f�efer to
dravvi9gs 160A Z for s�andard plate positions.
Alpine, a division of ITW Buildina Components Groua Inc. shall not be responsible for anv deviation from this drawina.anv failure to build the
i F9 T , or Tor ITacce to ce
any structure
g or cover pale
in. The sgbility
3670 COMMERCE CENTER
SEBRING, FL 33870
(863)385-8242
IJob Number. 91191 Ply: 1 SEQN: 26368 / T44 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: All 1 Wgt: 270.2 Ibs / ... 05/22/2020
r 282-12"
—+ 405/16"-1 1T1-5/16' — -�
F®5X6
T3 T4 H 6
/3X4E T2
12 W7 %3X
t 5 � I W5 W10 T5
'05X6D
b � W1
T1 W6 X
f3X4C W3 W4 W12 J%4
W
W14
B W1 W2 R B2 Q P N M 84 L �3 U
®A5(A1) 3X4-4X4=H0308 =3X6=3X8 =-3X8
B1 l2X4 S= X6
SEAT PLATE REQ. SEAT PLATE REQ.
k VIC
f- 2'
4s
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.23 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.60 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 it
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
DefI/CS1 Criteria
PP Deflection in too L/defl L/#
VERT(LL): 0.090 G 999 360
VERT(TL): 0.167 G 999 240
HORZ(LL): 0.015 K - -
HORZ(TL): 0.031 K - -
Creep Factor: 2.0
Max TC CSI: 0.707
Max BC CSI: 0.773
Max Web CSI: 0.837
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
"'WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT'" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING l
quire extreme care in fabricating, handling, shipping, installing and bracing. _ Refer to ani
Of
l PI 1, or for h
acceptance
any sructure
as shown above and on
Of
SEAT PLATE REQ.
�11
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 551 /- /-
/349 /199 1524
S 1784 /- A
/1258 /638 A
U 1261 A /-
/806 /373 A
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
S Big Width = 8.0
Min Req = 2.1
U Brg Width = 8.0
Min Req = 1.5
Bearings B, S. & U are a rigid surface.
Bearings B, S. & U require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
F- G 1342 -1336
B - C 239 -575
G - H 1459 -1514
C - D 419 -359
H -1 1483 -1702
D-E 1119 -1294
I-J 1411 -1770
E - F 1329 -1367
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - T
478 -287
O - N
1595 -1188
T - S
473 -289
N - M
1595 -1188
R - Q
47 -52
M - L
1600 -1222
Q-P
1154 -800
L-K
34 -41)
P-O
1154 -800
Maximum Web Forces Per Ply(Ibs)
Webs Tens.Comp. Webs Tens. Comp.
T- C
276 0
O- G
798
-694
C - S
417 -595
G - M
275
-160
S - R
1152 -1486
M - H
388
-261
R-D
1181 -1424
M-1
216
-205
D - Q
1315 -920
I - L
388
-286
Q - E
491 -446
L - J
1602
-1216
E-0
171 -101
J-K
1056
-1207
F - O
685 -577
failure to buiilpldda� pthe 3670 COMMERCE CENTER
or 1%. TheesUitability s (�j3FL 2 2870
IJob Number. 91191 Ply: 1 SEQN: 26369 / T51 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: Al2 Wgt: 264.6 Ibs / ... 05/22/2020
67-70 1- a'0-&16"-1 101-5/16• -�
' ®5X6
T2 T3 s5X6
/3X4E W7 CL T4 H
12 .
b 5 1
®5X60 W5 (aW10 I' T5
b )
0 W6 W9 W1
03X4C W3 W4 W12W W14
W14
W1 VQ R 82 Q P O B3 N M B3 L 13 U
®3X5(A1) B 3X4 =4X4 =H0308 =W =W--21X8
A
81 T S= X6
A�xa
SEAT PLATE REQ.
r----12'4"
SEAT PLATE REQ.
SEAT PLATE REQ.
33
�-2' -}- 123-10 33'840
49
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in Ioc Udell L/#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA VERT(LL): 0.087 G 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.162 G 999 240
B 551 /- /- /349 /200 /524
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.013 E - -
S 1783 /- /- /1252 /629 /-
EXP: D
Des Ld: 37.00
HORZ(TL): 0.027 E - -
U 1261 /- /- /800 /342 /-
Mean p :15.23 ft
NCBCLL: 10.00 TCDL: 4sf
Code / Misc Criteria Creep Factor: 2.0
Wind reactions based on MWFRS
.0
Soffit: 0.00 BCDL: 6.0 psf
Bldg Code: FBC 2017 RES Max TC CSI: 0.707
B Brg Width = 8.0 Min Req = 1.5
Load Duration:1.25 MWFRS Parallel Dist: > 2h
TPI Std: 2014 Max BC CSi: 0.504
S Brg Width = 8.0 Min Req = 2.1
U Brg Width = 8.0 Min Req = 1.5
Spacing: 24.0 " C&C Dist a: 4.60 It
Rep Factors Used: Yes Max Web CSi: 0.818
Bearings B, S, & U are a rigid surface.
Loc. from endwali: not in 13.00 It
FT/RT:20(0)/10(0) Mfg Specked Camber.
Bearings B, S, & U require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 44 0 F - G 1315 -1375
Value Set: 13B (Effective 6/1/2013)
B - C 241 -575 G - H 1464 -1592
Top chord 2x4 SP #2
C - D 418 -358 H - I 1520 -1772
Bot chord 2x4 SP #2 :B3 2x4 SP M-31:
D - E 1103 -1292 I - J 1370 -1673
Webs 2x4 SP #2
E - F 1306 -1376
Lumber value set "138" uses design values
approved 1/30/2013 by ALSC
Maximum Bot Chord Forces Per Ply (Ibs)
Bracing
Chords Tens.Comp. Chords Tens. Comp.
(a) 1 x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
B - T 478 -287 O - N 1792 -1398
length of web member. Attach with 8d Box or Gun
T - S 473 -290 N - M . 1792 -1398
(0.113'1x2.6%min.)nails @ 6" OC.
R - Q 44 -49 M - L 1527 -1198
Q-P 1151 -783 L-K 22 -27
Loading
P - O 1151 -783
Bottom chord checked for 10.00 psf non -concurrent
live load.
Maximum Web Forces Per Ply (Ibs)
Purlins
Webs Tens.Comp. Webs Tens. Comp.
In lieu of rigid ceiling provide lateral bracing to brace
T- C 276 0 O - G 869 -774
BC @ 24" OC
C - S 416 -594 G - M 482 -359
S - R 1138 -1486 M - H 444 -349
Additional Notes
R-D 1169-1422 M-I 171 -86
WARNING: Furnish a copy of this DWG to the
D - Q 1308 -899 I - L 418 _391
installation contractor. Special care must be taken
Q - E 475 -454 L - J 1552 -1206
during handling, shipping and installation of trusses.
E - O 184 -105 J - K 1055 -1211
See "WARNING" note below.
F-O 645 -478
*"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme e in fIb-ca
ting handlin , shi prng, installing,and bracing. Refer to and followthe latest editionofBCSI(Building
Sfety Information bTPI and SBCA) for safely practices poor to performing these functions. Installers shall provide temporaryBCSI Unless notes herwise,top chord shall have properly attached structural sheathin and bottom chord shall havpro rd ceilingg Locationshown for permanent lateral restraint of webs shall have bracing�rns ailed per BCSI sections 63, 67 or �10, SCOSTA CORPORATION
le. Apply plates to each face of truss and position assown
sshown above and on the Joint Details, unless noted otherwise. Refer to WOOD STEEL OR TIMBER
60A- for Standard plate positiQOS. ROOF bR FLOOR TRUSSES
Of
TPI 1, or for h
acceptance
anystructure
failure to build the 3670 COMMERCE CENTER DRI\
or cover Page SEBRING. FL 33870
r . The sEjitgbility (863)385.8242
Job Number: 91191 Ply: 1 SEQN: 26370 / T46 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A13 Wgt: 261.8 Ibs / ... 05/22/2020
252-12° i87-7/8"—+4'05/16" 815/16' — -�
F®5X6
T2 T3
H X6
12 OWE � T4
Gar
5 p 12X4O
b /5X6D W5 (a VV1 I T5
0W6 J%4X
i3X4C V13 W4 yy
w1a
®3X5(A1)B wi W2 C 82 P O N B3 =—M B3 L 13
3X4 =4X4 =—H0308 IS 5x8 --4X10
A
81 S = X6
�7YA
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
r---174" 33'8"
2' 'f' 123-12"
46
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT. NA PP Deflection in loc Udell L/#
Gravity Non -Gravity
Speed: 159 mph
TCDL: 7.00 P P
Pf: NA Ce: NA VERT(LL): 0.105 G 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.195 G 999 240
B 550 /- A 1349 /199 /524
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.019 K - -
R 1787 A A /1247 /621 /-
EXP: D
i Des Ld: 37.00
HORZ : 0.039 K - -
iTL)
T 1260 /- A /794 /337 /-
Mean Height:15.23 It
NCBCLL: 10.00 TCDL: 4.0 psf
Code / Misc Criteria CreepFactor: 2.0
Wind reactions based on MWFRS
Soffit: 0.00 BCDL: 6.0 psf
Bldg Code: FBC 2017 RES Max TC CSI: 0.874
B Brg Width = 8.0 Min Req = 1.5
Load Duration:1.25 MWFRS Parallel Dist: > 2h
TPI Std: 2014 Max BC CSI: 0.947
R Big Width = 8.0 Min Req = 2.1
T Brg Width = 8.0 Min Req = 1.5
Spacing: 24.0 " C8,C Dist a: 4.60 It
Rep Factors Used: Yes Max Web CSI: 0.985
Bearings B, R, & T are a rigid surface.
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0) Mfg Specified Camber.
Bearings B, R, & T require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 44 0 F - G 1291 -1402
Value Set: 13B (Effective 6/1/2013)
B - C 236 -572 G - H 1839 -2020
Top chord 2x4 SP #2
C - D 420 -358 H -1 1495 -1616
Bot chord 2x4 SP #2
D - E 1078 -1285 I - J 1324 -1609
Webs 2x4 SP #2
E - F 1292 -1373
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Maximum Bot Chord Forces Per Ply (Ibs)
Bracing
Chords Tens.Comp. Chords Tens. Comp.
(a) 2x4 #3 or better "T' reinforcement. 80% length of
B - S 475 -282 O - N 1144 -758
web member. Attach with 16d Box or Gun
S - R 471 -284 N - M 2046 -1598
(0.135"x3.5",min.)nails @ 6" OC.
Q - P 49 -56 M - L 1565 -1193
P-0 1144 -758 L-K 13 -17
Loading
Bottom chord checked for 10.00 psf non -concurrent
Maximum Web Forces Per Ply (Ibs)
live load.
Webs Tens.Comp. Webs Tens. Comp.
Purlins
S- C 276 0 N- G 980 -961
In lieu of rigid ceiling provide lateral bracing to brace
C - R 414 -594 G - M 595 -428
BC@24"OC
R-Q 1129-1491 M-H 755 -612
Q-D 1158 -1428 H-L 112 -190
Additional Notes
D - P 1308 -878 L - I 429 -257
WARNING: Fumish a copy of this DWG to the
P - E 472 -445 L - J 1532 -1205
installation contractor. Special care must be taken
E - N 194 -121 J - K 1068 -1230
during handling, shipping and installation of trusses.
F - N 619 -402
See "WARNING" note below.
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabricatinNhed
nlin ,shipppinginstallingand bracing. Refertoandfollowthe latest edition of BCSI(BuildingfSafetyIformation b TPI anBCA)or ieTypractnor toperforming hesefunctons. Installrsslprovide temposUnessnoted o herwisep chord sh�a I have properiattached structural sheathin and bottom chord shall haveaprrylyilinggLocationsshownfoermanent lateral restraint of webs shall have bracing9�msalled per BCSI sections B3, B7 or10, SCOSTA CORPORATION
le. eppl�r plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. f�efer to WOOD STEEL. oR T MBER
60A-LZ fo standard plate positions. ROOF bR FLOOR TE�USSES
Of
IIvi 1,orforn
r
accetance
any structure
ilure to build the 3670 COMMERCE CENTER DRII
or cover a eSEBRING, FL 33870
The s 1 bility (863)385-8242
Job Number. 91191 Ply: 1 SEQN: 26371 / T53 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A14 Wgt: 274A Ibs .. / ... 05/22/2020
252-12° f107-7/8" 14'05116" 1 99-118" �
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
12'4" 37'313/16"
�- 2' 1 12'3-1/2"
Loading Criteria (pst)
Wind Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height:15.23 it
NCBCLL: 10.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration:1.25
MWFRS Parallel Dist:> 2h
Spacing: 24.0 "
C&C Dist a: 4.97 ft
Loc. from endwall: not in 13.00 It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 61112013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2 :B3 2x4 SP M-31:
Webs 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
length of web member. Attach with 8d Box or Gun
(0.113"x2.6%min.)nails @ 6' OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT. W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE, HS
3T4-5/16"
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.203 H 999 360
VERT(TL): 0.378 H 999 240
HORZ(LL): 0.038 F - -
HORZ(TL): 0.074 F - -
Creep Factor: 2.0
Max TC CSI: 0.712
Max BC CSI: 0.722
Max Web CSI: 0.989
Mfg Specked Camber.
VIEW Ver: 18.02.01A.0205.19
-WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
of
any
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 543 /- /-
/333 /223 /524
T 1935 /- A
/1322 /622 /-
K 1400 /- A
/931 /395 /-
Wind reactions based on MWFRS
B Big Width = 8.0
Min Req = 1.5
T Brg Width = 8.0
Min Req = 2.3
K Big Width = 8.0
Min Req = 1.7
Bearings B, T, & K are a rigid surface.
Bearings B, T, & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
F- G 1487 -1571
B - C 333 -556
G - H 2536 -2903
C - D 475 -354
H -1 2145 -2457
D - E 1233 -1424
I - J 2247 -2679
E - F 1456 -1574
J - K 2482 -3064
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - U
460 -256
P - O
2193 -1579
U - T
455 -259
O - N
2928 -2234
S - R
86 -98
N - M
2928 -2234
R - Q
1275 -799
M - L
2777 -2174
Q - P
1275 - 799
L - K
2780 -2171
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
U- C
278 0
P- G
1093
-1096
C - T
415 -595
G - O
1049
-821
T - S
1188 -1641
O - H
893
-836
S - D
1214 -1575
H - M
604
-685
D - R
1497 -964
M -1
763
-583
R-E
511 -533
M-J
418
-386
E- P
228 -97
J- L
178
0
F - P
809 -668
ns ti tsrf�efer nu' —
SCOSTA CORPORATION
a
ierviiROOF
bR FLOOR TRUSSES
failure to build the
3670 COMMERCE CENTER DRIB
i or cover pa e, ,
SEBRING, FL 33870
. The sUi blllty
(863)W5-8242
Job Number: 91191 Ply: 1 SEQN: 26372 / T63 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW.
Truss Label: A15 Wgt: 264.6 Ibs / ... 05/22/2020
r 252-1/2' + 127-7/8"
T
snc
NT
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
124" i3T3-13/16"
2 123-1/2" + 3T45/16' 2 -
r
49'7-13/16
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl/CSl Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT. NA PP Deflection in foe Udefl U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA VERT(I-Q: 0.219 H 999 360
Lee R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(rL): 0.403 H 999 240
B 543 /- /- 1320 /236 /576
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.042 F - -
S 1934 /- /- /1335 /583 /-
EXP: D
Des Ld: 37.00
HORZ 0.081 F - -
(TI-)�
J 1516 /- /- /1091 /452 /-
Mean Height:15.23 It
NCBCLL: 10.00 TCDL: 4.0 psf
Code
Code / Misc Criteria Creep Factor: 2.0
reactions based on MWFRS
Soffit: 0.00 BCDL: 6.0 psf
Bldg Code: FBC 2017 RES Max TC CSI: 0.862
B Brg Width = 8.0 Min Req = 1.5
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
TPI Std: 2014 Max BC CSI: 0.935
S Brg Width = 8.0 Min Req = 2.3
J Brg Width = 8.0 Min Req = 1.8
Spacing: 24.0 " C&C Dist a: 4.97 ft
Rep Factors Used: Yes Max Web CSI: 0.995
Bearings B, S, $ J are a rigid surface.
Loc. from endwall: not in 13.00 It
FT/RT:20(0)/10(0) Mfg Speed Camber.
Bearings B, S, & J require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02. 11A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - B 44 0 F - G 1467 -1565
Value Set: 136 (Effective 6/1l2013)
B - C 421 -554 G - H 2403 -2893
Top chord 2x4 SP #2
C - D 510 -409 H -1 2234 -2668
Bot chord 2x4 SP #2 :B3 2x4 SP M-31:
D - E 1246 -1416 I - J 2252 -2895
Webs 2x4 SP #2
E - F 1430 -1565 J - K 44 0
Lumber value set "l3B" uses design values
approved 1/30/2013 by ALSC
Maximum Bet Chord Forces Per Ply (Ibs)
Bracing
Chords Tens.Comp. Chords Tens. Comp.
(a) 1x4 #2 SYP,HF,OR SPF "T' reinforcement. 80%
B - T 458 -253 O - N 2189 -1415
length of web member. Attach with 8d Box or Gun
T - S 453 -255 N - M 3374 -2481
(0.113'k2.5",min.)nails @ 5' OC.
R - Q 94 -104 M - L 3374 -2481
Q-P 1269 -702 L-J 2599 -1872
Loading
P - O 1269 -702
Bottom chord checked for 10.00 psf non -concurrent
live load.
Maximum Web Forces Per Ply (Ibs)
Purlins
Webs Tens.Comp. Webs Tens. Comp.
In lieu of rigid ceiling provide lateral bracing to brace
T - C 278 0 F - O 814 -672
BC @ 24" OC
C - S 413 -595 O - G 1051 -1103
S - R 1105 -1640 G - N 982 -693
Additional Notes
R - D 1130 -1573 N - H 1053 -1042
WARNING: Furnish a copy of this DWG to the
D - Q 1497 -865 H - L R16 -938
installation contractor. Special care must be taken
Q - E 468 -533 L - I 768 -508
during handling, shipping and installation of trusses.
E - O 214 -89
See "WARNING" note below.
-WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabriptinp handlin shi in installing,and bracing. Referto and followthe latest edition of BCSI (Building
t Safety Information b TPI and SBCA) to' sate y practices poor to performing these functions Installers shall provide temporary
BC;PpVlatetoe.chface0PSS.nd
., Unless noted oherwise,top chord shall have propedy attached structural sheathingp and bottom chord shall have a proppeerly
qqid lingg. Locations shown for permanent lateral restraint of webs shall have bracincLrnslalled per BCSI sections B3, B7 or 610, SCOSTASCOSTA CORPORA��N
rle. ly position as shownboveand on the Joint Details, unless noted otherwise. f�efer to WOOD STEELORTIMBER60Aforsndard plate positionROOF bR FLOOR TRUSSES
of
rrPI 1, or for h
acceptance
anystructure
failure to build the 3670 COMMERCE CENTER DRI\
or cOVer e _ SEBRING, FL 33670
r . The s I bilrty (863)365-8242
Job Number. 91191 Ply: 1 SEQN: 26373 / T62 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A16 Wgt: 253.4 Ibs / ... 05/22/2020
25' 4-1¢ 1� 6" 14'5-7/16" 4 /1� 99-1B"
io
r--- 7'1-1/2" 42'6-5/16"
��{� TV 42'6-13/16" _ - 2' J
r 497-13/16"
Loading Criteria (pst) Wind Criteria
Snow Criteria (Pg,Pi in PSF) Defl/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in too Udefl U#
Gravity
Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf. NA Ce: NA VERT(LL): 0.307 N 999 360
Loc R+ / R- / Rh
/ Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.567 N 900 240
B 371 /- /-
/193 /222 /572
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.079 L - -
S 1872 P P
/1315 /587 /-
EXP: D
Des Ld. 37.00
HORZ 0.145 L - -
(T-)
J 1724 !- /-
/1145 l478 /-
Mean Height:15.18 ft
NCBCLL: 10.00
Code / Misc Criteria Creep Factor: 2.0
Wind reactions based on MWFRS
TCDL: 4.0 psf
Soffit: 0.00
Bldg Code: FBC 2017 RES Max TC CSI: 0.777
g Big Width = 8.0
Min Req = 1.5
BCDL: 6.0 psf
p
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
TPI Std2014 Max BC CSI0596
: : .
S Big Width = 8.0
J Big Width = 8.0
Min Req = 22
Min Req = 1.5
Spacing: 24.0 " C&C Dist a: 4.97 It
Rep Factors Used: Yes Max Web CSI: 0.912
Bearings B, S, & J are a
rigid surface.
Loc. from endwall: not in 13.00 It
FT/RT:20(0)/10(0) Mfg Specked Camber.
Bearings B, S, & J require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp.
Chords Tens. Comp.
Lumber
A - B 0
F - G -2212
Value Set: 13B (Effective 611/2013)
B-C 471 -494
G-H 2742 -3636
Top chord 2x4 SP #2 :T2, T3 2x4 SP M31:
C - D 378 -373
H - I 2522 -3312
Bot chord 2x4 SP M-31 :B1 2x4 SP 92:
D - E 1915 -2578
I -J 2558 -3508
Webs 2x4 SP #2
E - F 1792 -2212
J - K 44 0
Lumbervalue set "13B" uses design values
approved 1/30/2013 by ALSC
Maximum Bot Chord Forces Per Ply (Ibs)
Bracing
Chords Tens.Comp.
Chords Tens. Comp.
(a) 1x4 #2 SYP,HF,OR SPF -r reinforcement. 80%
B - S 28 -31
O - N 2845 -1769
length of web member. Attach with 8d Box or Gun
R - Q 2227 -1413
N - M 4867 -3577
(0.113"x2.5",min.)nails @ 6" OC.
Q - P 2354 -1382
M - L 4867 -3577
(b) 2x4 #3 or better "T' reinforcement. 80% length of
P - O 2354 -1382
L - J 3175 -2172
web member. Attach with 16d Box or Gun
(0.135"x3.5",min.)nails @ 6" OC.
Maximum Web Forces Per Ply (Ibs)
Loading
Webs Tens.Comp.
Webs Tens. Comp.
Bottom chord checked for 10.00 psf non -concurrent
C - R 302 -289
F - O 1347 -1020
live load.
R - S 1241 -1802
O - G 1093 -1192
R - D 1809 - 2695
G - N 1003 -639
Purlins
D-Q 332 -1
N-H 1674 -1735
In lieu of rigid ceiling provide lateral bracing to brace
Q - E 269 0
H - L 1670 -1855
BC @ 24" OC
E - O 565 -524
L - I 1144 -778
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
—IMPORTANT-
of
FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
the latest edition of BCSI (Building
Installers shall provide temporar botto chord shall have a prop ely
per 13 SI sections B3, B7 or B10, SCOSTA CORPORATION
anless noted otherwise. Defer to WOOD STEEL
OR TIMBER
TPI T, or for h
acceptance
any sructure
R LO
ROOb F FOR TRUSSES
failure to build the 3870 COMMERCE CENTER DRh
g or cover ppaa�gge SEBRING, FL 33870
In. The sUrtability (863)385-8242
Job Number: 91191 Ply: 1 SEQN: 26417 / T15 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: Al Wgt: 320.6 Ibs / ... 05/22/2020
23, 4'4-15/16" 14'5-7/16" 4'0-5/16" 39-1/8"
r
SEAT PLATE REQ. SEAT PLATE REQ. SEAT PLATE REQ.
7'1-112 42'6-5119'
r r �+ T1" 42'6-13/16" 2'
497-13/16"
Loading Criteria (pA
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in loc Udell L/#
Gravity Non -Gravity
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): 0.361 N 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.666 N 767 240
B 350 /- /- !- /227 /-
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.072 F - -
V 1996 P P P /1164 /-
Des Ld: 37.00
EXP: D
HORZ(TL): 0.133 F -
K 2512 P /- P /1298 P
NCBCLL: 10.00
Mean Height:15.00 ft
Code / Misc Criteria
Creep Factor: 2.0
Wind reactions based on MWFRS
Soffit: 0.00
. TCDL: 40 psf
BCDL: 6.0 sf
p
Bldg Code: FBC 2017 RES
Max TC CSI: 0.852
B B Width = 8.0 Min Re 1.5
q =
Load Duration:1.25
MWFRS Parallel Dist: 0 to h/2
TPI Sid: 2014
Max BC CSI: 0.488
V Big Width = 8.0 Min Req = 2.
K Big Width = 8.0 Min Req = 2.1
Spacing: 24.0 "
C&C Dist a: 4.97 it
Rep Factors Used: Varies by
Ifmb CSI: 0.917
Bearings B, V, & K are a rigid surface.
Loc. from endwall: not in 9.00 it
FT/RT:20(0)/10(0)
Mfg Specified Camber.
Bearings B, V, & K require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE, HS
VIEW Ven 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A- B 44 -44 G - H 1906 -3393
Value Set: 13B (Effective 6/1/2013)
B - C 208 -160 H -1 3137 -5822
Top chord 2x4 SP #2 :T2, T4, T5 2x4 SP M-31:
C - D 1362 -2465 I - J 2504 -5141
Bot chord 2x8 SP 2400f-2.0E :B1 2x4 SP #2:
D - E 1238 - 2347 J - K 2560 -5193
Webs 2x4 SP #2
E - F 1538 -2705 K- L 44 -44
Lumber value set "13B"
uses design values
F - G 1321 -2346
approved 1/30/2013 by ALSC
Special Loads
---(Lumber Dur.Fac =1.25 / Plate Dur.Fac. 1.25)
TC: From 55 plf at -2.11 to 55 pif at 51.76
BC: From 20 plf at 0.00 to 20 plf at 49.65
BC: 858 lb Conc. Load at 46.52
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC@24"OC
Additional Notes
WARNING: Furnish a copy of this DWG to the
installation contractor. Special rare must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-V
78 -118
Q-P
2417 -1378
U-T
50 -77
P-O
4113 -2331
T - S
2562 -1507
O - N
4113 -2331
•S - R
2240 -1283
N - M
7927 -4267
R - Q
2240 -1283
M - K
4783 -2347
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Camp.
U - V
1196 -1929
Q - G
202 -251
U-C
1158 -1807
G-P
1329 -619
C - T
2326 -1256
P - H
893 -1444
T- E
499 -548
H - N
1897 -809
E - S
240 -210
N -1
1598 -2928
S - F
380 -98
I - M
1890 -2986
F - Q
375 -135
M - J
1808 -791
""WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
-IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handling shi ing, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
Componenf Safety Information by TPI pnr7 SBCA) toy."Fetpy practices pnor to performing these f nctions Installers shall provide temporary
bracing er BCSI.. Unless noted o herwise,top chord shall have properly attached structural sheatkin and botto n chord shall have a property
attache rigid ceilingg Locations shown forpermanent lateral restraint of webs shall have bracincLins ailed per BCSI sections B3, B7 or B10, SCOSTA CORPORATION
as applicable. AppTjr elates to each face, of truss and position as shown above and on the Joinge'tails, unless noted otherwise. kefer to WOOD STEEL OR TIMBER
dravrings 160A Z for standard plate positions. ROOF bR FLOOR TRUSSES
Alpine. a division of ITW Buildinc Comoonents Group Inc. shall not be responsible for anv deviation from this drawina.anv failure to build the 3670 COMMERCE CENTER DRI\
rri i,orTor n
acceptance
any structure
or cover e, , SEBRING, FL 33870
/ . The s ' bllrty (863)385-8242
Job Number. 91191 Ply: 1 SEQN: 26374 / T64 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A18 Wgt: 238.0 Ibs .. / ... 05/22/2020
21' -i- 8'4-15/16" A. 14'5-7/16" T 3/q
ObAb vbXe
E T3 F
T2
12 W W %3XX4 T4
5 ®5X6D
®4X6 W6 W5 yy a°6X8(SRS) 102C4
T1 C W4 W3 H 9 Ie6X8
W2 W9
RW1 Q B2 P O� B3 N M L B4 K J
=3AX5(A1) B 3X4 =4X6 =H0308 =3X4 _H0308 =3X4 =3X4
BI S 01 X6
SEAT PLATE REQ. SEAT PLATE REQ
39'3-1/16"
Loading Criteria (psf)
Wind Criteria
TOLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des .00
Des Ld.37es
Mean Height: 15.00 ft
: .00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 4.64 ft
Loc. from endwall: not in 13.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 :T2, T4 2x4 SP M31:
Bot chord 2x4 SP #2 04 2x4 SP M31:
Webs 2x4 SP #2
Lumber value set 13B" uses design values
approved 1/30/2013 byALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
WARNING: Fumish a copy of this DWG to the
installation contractor. Special care must be taken
during handling, shipping and installation of trusses.
See "WARNING" note below.
Provide hanger or special connection at right end of
truss for 1471 Ibs.
46'4-9/16"
Snow Criteria (Pg,PF in PSF)
Pg: NA Ct: NA CAT: W
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE, HS
39'3-9/16"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.219 L 999 361)
VERT(TL): 0.408 L 999 240
HORZ(LL): 0.064 J - -
HORZ(TQ: 0.118 J - -
Creep Factor: 2.0
Max TC CSI: 0.924
Max BC CSI: 0.826
Max Web CSI: 0.670
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
any
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 356 P P
/217 /172 1440
S 1807 P /-
/1234 /612 P
J 1471 P P
/881 /401 P
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
S Big Width = 8.0
Min Req = 2.1
J Big Width = -
Min Req = -
Bearings B & S are a rigid surface.
Bearings B & S require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
E - F 1811 -2096
B - C 408 -386
F - G 2124 -2714
C - D 1469 -2065
G - H 2677 -3609
D - E 1809 -2331
H -1 6 -33
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-S
93 -102
N-M
2122 -1431
R-Q
144 -163
M-L
2122 -1431
Q - P
2126 -1541
L - K
3086 -2302
P - O
2126 -1541
K - J
4418 -3555
O - N
1975 -1353
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
R - S
1343 -1737
N - F
276
-200
R - C
1343 -1702
F - L
658
-412
C - Q
2096 -1449
L - G
822
-791
Q - D
535 -519
G - K
475
-142
D - O
247 -155
K - H
1202
-1148
O - E
307 -50
H - J
3710
-4590
E - N
372 -166
I - J
105
-76
SCOSTA CORPORATION
ROOF bR FLOOR TRUSSES
failure to build the 3670 COMMERCE CENTER DRn
IXor cover page SEBRING, FL 33870
The stfillibility (863)365-6242
Job Number. 91191 Ply:1 SEQN: 26375 / T1 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW.
Truss Label: A19 Wgt: 250.6 lbs / ... 05/22/2020
r 19, 12'4-15/16" 10'63/16" -�
SEAT PLATE REQ. SEAT PLATE REQ.
j 7'5-1/2" --�
�-A_-7'1°
Loading Criteria (pat)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 4.19 It
Loc. from endwall: not in 13.00 It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set:13B (Effective 611/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP 92
Webs 2x4 SP #2
:Rt Bearing Leg 2x4 SP #2:
Lumber value set "1313" uses design values
approved 1/30/2013.byALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide hanger or special connection at right end of
truss for 13051bs,
41'11-1/8"
Snow Criteria (Pg,PF in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
34'2-1/8"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.122 F 999 360
VERT(fL): 0.227 F 999 240
HORZ(LL): 0.061 K - -
HORZ(TL): 0.114 K - -
Creep Factor: 2.0
Max TC CSI: 0.683
Max BC CSI: 0.634
Max Web CSI: 0.781
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 366 A /- /244 1155 1395
T 1611 A (- /1114 1695 P
J 1305 /- P /758 /403 P
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
T Brg Width = 8.0 Min Req = 1.9
J Brg Width = - Min Req = -
Bearings B & T are a rigid surface.
Bearings B & T require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 1658 -1925
B - C 316 -339 F - G 1668 -1925
C - D 1491 -2069 G - H 1483 -1802
D - E 1551 -1949 H -1 1408 -1820
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - T 57 -52 P - O 1737 -1203
S-R 51 -30 O-N 1615 -1096
R - Q 1870 -1352 N - L 1643 -1206
Q-P 1737-1203 M-K 17 -4
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
S-T
1230 -1540
G-N
201
-44
S - C
1250 -1490
N - H
192
-149
C-R
1914-1381
H-L
314
-271
R- D
327 -209
L- M
108
0
D-Q
171 -202
L-K
62
-80
E-Q
306 -7
L-I
1620
-1182
E- O
272 -237
J- K
97
0
F - O
437 -356
I - J
1569
-1489
O - G
429 -338
-WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabripi; handlin , shi ping, installing,and bracing. Ref
erto and followthe latest edition of BCSI (Building
t Safety Information b� TSBCA) for safety practices poor to performing these functions Installers shall provide tempos
r BCSI. Unless noted o heop chord shall have propedy attached structural sheathin and bottom chord shall have a pro rryly
qqid ceiling Locations shopermanent lateral restraint of webs shall have bracincLinsalled per BCSI sections B3, B7 or10,
le. Apply lates d each of truss and position as shown above and on the Joint Details, unless noted otherwise. F�efer to
60A Z for s�andard plate positions.
of
failure to build the 3670 COMMERCE CENTER
or cover pageSEBRING, FL 33870
1. The sp 9bihty (863)385-8242
I/N&A Truss IC�ONNSTRUO CONSTRUCTION /JURADO/COD /KCD I Wat i236.6 Ibs FROM: 26376 / T52 /HIPS I DRW% 06122/2020
1T
SEAT PLATE REQ. SEAT PLATE REQ.
k— 7'1-1l2" A-
16'4-15/16"
34'9-5/8"
963116' =-{
I
X5 b
2'+--TV +
29'0-1/2"
41'11-1/9'
69-5/8"�{
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Deft/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in loc Udell U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): 0.144 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA
VERT(rL): 0.268 F 999 240
B 375 /- /- /281 /157 /357
BCDL: 10.00 Risk Category: II
Snow Duration: NA
HORZ(LL): 0.077 J - -
R 1585 /- /- /1063 1687 /-
EXP: D
Des Ld: 37.00
HORZ(TL): 0.142 J - -
J 1312 !- /- /748 /448 /-
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.0 psf
Code / Misc Criteria
Creep Factor: 2.0
Wind reactions based on MWFRS
Soffit: 0.00 BCDL: 6.0 psf
p
Bldg Code: FBC 2017 RES
Max TC CSI: 0.826
B B Width = 8.0 Min Req = 1.5
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Max BC CSI: 0.938
R Brg Width = Min Req = 1.9
J Brg Width = - Min Req = -
Spacing: 24.0 " C&C Dist a: 4.19 ft
Rep Factors Used: Yes
Max Web CSI: 0.760
Bearings B & R are a rigid surface.
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
Mfg Specked Camber.
Bearings B & R require a seat plate.
GCpi: 0.18
Plate Type(s):
Maximum Top Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE
VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber
Value Set: 13B (Effective 611/2013)
A - B 44 0 E - F 1765 -2134
B - C 223 -269 F - G 1683 -2046
Top chord 2x4 SP #2
C - D 146 -163 G - H 1605 -1842
Bot chord 2x4 SP #2
D - E 1603 -2108 H - I 1457 -1868
Webs 2x4 SP #2
Lumber value set "13B" uses design values
Maximum Bot Chord Forces Per Ply (Ibs)
approved 1/30/2013 by ALSC
Chords Tens.Comp. Chords Tens. Comp.
Loading
B - R 22 -17 N - M 2284 -1674
Bottom chord checked for 10.00 psf non -concurrent
Q - P 1781 -1385 M - K 1704 -1231
time load.
P - O 1867 -1359 L - J 14 - 8
O - N 2284 -1674
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
Maximum Web Forces Per Ply (Ibs)
BC @ 24" OC
Webs Tens.Comp. Webs Tens. Comp.
Wind
C-Q 341 -325 M-G 550 -272
Right end vertical not exposed to wind pressure.
Q - R 1220 -1515 a G - K 175 -159
Q-D 1678-2121 K-L 113 0
Additional Notes
D - P 235 -19 K - H 387 _229
Provide hanger or special connection at right end of
P - E 173 -6 K -1 1713 -1276
truss for 1312 lbs.
E - O 430 -231 K - J 2 -6
O - F 341 -242 I - J 1070 -1255
F - M 439 -380
""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabricating handlin , shippting, installing,and bracing. Referto and followthe latest edition of BCSI (Building
if Safety Information b TPI an 'SBCA) for saffe y practices poor to performing these functions. Installers shall provide temporarx
r)3CSI. Unless noted oherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propenY
qqid ceiling Locations shown for permanent lateral restraint of webs shall have bracincLrns�alled per BCSI sections 63, B7 or 610, SCOSTA CORPORATION
le. Apply plates to each face of truss and position as shown above and on the Joinf"Details, unless noted otherwise, F�efer to WOOD STEEL OR TIMBER
60A-Z for standard plate'Illons. ROOF bR FLOOR TRUSSES
of
Fivi 1,ortorn
acceptance
any structure
failure to build the 3670 COMMERCE CENTER DRI\
q or cover p��qe_ , SEBRING, FL 33870
r9. The S tBbrhty (863)385-8242
Job Number. 91191 Ply:1 I SEQN: 26426 / T65 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: A21 Wgt: 271.6 Ibs / ... 05122/2020
15, 294-15/16" 6'6-3/16" —�
T
T
T
SEAT PLATE REQ. SEAT PLATE REQ.
k— 71-1/2 349-5/8"
�-2' TVA{- T1" Z6" 1951/2" -}- 59-5/8"
41'11-1/8"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category': II
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf -
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 4.19 It
Loc. from endwall: not in 13.00 It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at right end of
truss for 1294 lbs.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): 0.301 H 999 360
VERT(TL): 0.563 H 746 240
HORZ(LL):0.161 O - -
HORZ(TL): 0.299 O - -
Creep Factor: 2.0
Max TC CSI: 0.775
Max BC CSI: 0.809
Max Web CSI: 0.803
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
`*IMPORTANT'" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
of
ivi i,orrorn
acceptance
any structure
N %k4X5
io
n
W17 0
u
4
F-
I
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 331 /- A
/241 /127 P319
AB 1699 A A
/1094 1742 A
O 1294 A A
1723 /492 A
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
AB Big Width = 8.0
Min Req = 2.0
O Big Width = -
Min Req = -
Bearings B & AB are a rigid surface.
Bearings B & AB require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
H- I 1942 -2405
B - C 320 -336
1- J 2048 -2564
C - D 1127 -1566
J - K 2048 -2564
D - E 3272 -4310
K - L 1704 -2071
E - F 3429 -4331
L - M 1638 -1826
F - G 3196 - 4133
M - N 1466 -1845
G - H 3168 -4095
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B -AB
163 -198
U - T
2588 -1888
AA- Z
349 -451
T - S
2588 -1888
Z - Y
56 -41
S - R
2447 -1811
X - V
3577 -2576
R - P
1664 -1227
W-U
44 -33
Q-O
19 -6
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
AA AB
1339 -1637
V - U
2948 -2105
AA- C
1331 -1588
H - U
1052 -1356
C - Z
1939 -1418
U -1
288 -352
Z-D
1050-1287
I-S
121 -41
Z - X
1595 -1152
S - K
256 -22
D - X
2496 -1854
K - R
573 -646
E - X
302 -155
R - L
701 -433
X-Y
69 0
L-P
172 -207
X-F
972 -851
P-Q
113 0
F - V
907 -668
P - M
490 -251
G - V
152 -77
P - N
1694 -1279
V-W
32 0
P-O
0 -10
V - H
2O28 -1468
N - O
1067 -1235
SCOSTA CORPORATION
ROOF bR FLOOR TRUSSES
failure to build the 3670 COMMERCE CENTER DRI\
Ig or cover e_ SEBRING, FL 33870
A. The s 1 bllity (863)385-8242
Job Number: 91191 Ply: SEQN:
/N&A CONSTRUCTION /JURADO/COD /KCD I 1I FROM: 26378 / T14 /HIPS I DRW /
Truss Label: A22 Qt 225.4 Ibs 05/22/2020
13'
24'4-15/16"
-i- 4'6-3/16" -{
c5DX6 @E 6
O = F 6
5G
12Tb O
T5
T
5 p
H 012X4
W W
W
W
FO
in ®5X6C
W4
W4
W4 (a) W3
A
T7 W2
=3X8(A1) B
W5 0
� A
P B1 O N M B2
L K
=
J B2 — I
02X4 =3X4 =H0308 =3X4
=3X4 =H0308
=4X4
SEAT PLATE REQ.
41'11-1/8"
[-�2'—j
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,PP in PSF)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: N)
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 4.19 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/112013)
Top chord 2x4 SP #2 :T4 2x4 SP M31:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 2x4 #3 or better "T" reinforcement. 80% length of
Web member. Attach with 16d Box or Gun
(0.135"x3.5",min.)nails @ 6" OC.
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at right end of
truss for 1567 Ibs.
Defl/CSI Criteria
♦Maximum Reactions (Ibs)
PP Deflection in loc Udefl L/#
Gravity Non -Gravity
VERT(LL): 0.230 M 999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(TL): 0.428 M 999 240
B 1698 A A /1139 1658 1281
HORZ(LL): 0.0671 - -
I 1567 A /- /787 1669 /-
HORZ(TL): 0.1241 - -
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.962
1 Brg Width = - Min Req = -
Max BC CSI: 0.446
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Max Web CSI: 0.905
Mfg Specked Camber.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01A.0205.19
A - B 44 0 E - F 2275 -2865
B - C 2358 -3376 F - G 1564 -1932
C - D 2373 -3178 G - H 113 -65
D - E 2287 -2871
'*WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
any
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - P 3070 -2332 M - L 3032 -2298
P - O 3132 -2499 L - K 2585 -1978
O - N 2583 -2009 K- J 2585 -1978
N - M 2583 - 2009 J -1 1139 -891
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
P-C
277 -86
L-F
471 -210
C - O
431 -329
F - J
980 -1093
O - D
491 -230
J - G
1326 -839
D - M
485 -217
G -1
1382 -1764
M - E
347 -271
H -1
235 -135
E - L
326 -278
SCOSTA CORPORATION
ROOFDbR FLOOR TRUSSES
failure to build the 3670 COMMERCE CENTER DRn
I or cover e, SEBRING, FL 33870
I . The s ! billty (863)385-8242
Job Number. 91191 Ply: 1 SEQN: 26379 / T13 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW.
Truss Label: A23 Wgt: 2282 Ibs / ... 05/22/2020
2&4-15/16" i
2'6-3H6"I
T
—3X8(A1
A i
SEAT PLATE REQ.
41'11-1/8"
['- 2' -`{
Loading Criteria (p4
Wind Criteria
Snow Criteria (Pg,PP in PSF)
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
psf
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to It
TPI Sid: 2014
Spacing: 24.0 "
C&C Dist a: 4.19 ft
Rep Factors Used: Yes
Loc. from endwall: not in 13.00 it
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE, HS
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 :T2 2x4 SP M31:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumber value set "136" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
of
DefI/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.256 E 999 360
VERT(TL): 0.475 E 999 240
HORZ(LL): 0.074 J - -
HORZ(TL): 0.137 J - -
Creep Factor: 2.0
Max TC CSI: 0.662
Max BC CSI: 0.444
Max Web CSI: 0.827
Mfg Specked Camber.
VIEW Ver: 18.02.01A.0205.19
X4
JL
M
1
♦Maximum Reactions (Ibs)
Gravity . Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1698 P /- /1115 /1007 /273
J 1567 A /- /763 1926 P
Wind reactions based on MWFRS
B Big Width = 8.0 Min Req = 1.5
J Brg Width = 3.5 Min Req = 1.5
Bearings B & J are a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 E- F 2684 -3517
B - C 2336 -3365 F - G 2333 -3045
C - D 2373 -3180 G - H 1351 -1730
D - E 2472 -3171 H - I 59 -33
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - R
3065 -2341
N - M
3425 -2582
R - Q
3134 -2541
M - L
3425 -2582
Q - P
2748 - 2152
L - K
2557 -1957
P - O
2748 - 2152
K - J
791 -619
O - N
3497 -2661
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
R - C
329 -97
F - L
567 -623
C - Q
373 -285
L - G
801 -460
Q - D
350 -128
G - K
1153 -1358
D - O
693 - 409
K - H
1540 -1043
O - E
511 -537
H - J
1290 -1644
E-N
162 -57
I-J
126 -74
N - F
224 -52
"'WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
JT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
r care in fabricating handlin ship rng, installing, and bracing. Refer to and follow the latest edition of BCSI (Building
mation b TPI and SBCA) toi safe y practices pnor to performing these functions. Installers shall provide temporary
s notea o�herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proppeerty
acations shown for permanent lateral restraint of webs shall have bracing -installed per BCSI sections B3, B7 or B10, SCOSTA CORPORATTOW
ates to each face of truss and position as shown above and on the Joint -Details, unless noted otherwise. kefer to WOOD STEEL OR TIMBER
ndard plate positions. ROOF bR FLOOR TRUSSES
I rl 1, or tar n
acceptance
any structure
failure to buildthe3670 COMMERCE CENTER DR])
r%. The spi Ability S (8w� B,5- 870
Job Number. 91 f91 Ply:
SEQN:
I T &A CONSTss Label: RUCTION /JURADO/COD /KCD IA24 W t 11 Ibs I FROM: 26380 / T81 / HIPM I DRW / OS/22/2020 I
i 9,
32'11-1/8"
5 12 �D 6 T2 E 6 T2 FX6 T2 GX6 T3 -5 H
__1 T1 TT
tk2X4C W W ! io
W3 W3 W3 W3 W4
3X8(A1) B W1 0
A
61 P O N 82 M L K 62 J p13X It
=3X4 =H0308 =3X5 =3X4 =H0308 -3X5 =5X6
SEAT PLATE REQ.
�— 2' —{
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,PP in PSF)
DeHICSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: NA
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): 0.345 M 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.641 M 782 240
B 1698 P A 11087 /1007 /285
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.085 1 - -
1 1567 P P 1769 /932 P
Des Ld: 37
EXP: D.00
HORZ(TL): 0.157 I - -
Wind reactions based on MWFRS
NCBCLL: 10.00
Mean Height:15.00 ft
TCDL: 4.0 Height:
Code I Misc Criteria
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.5
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.769
1 Brg Width = 3.5 Min Req = 1.5
Load Duration:1.25
MWFRS Parallel Dist: h/2 to h
TPI Std: 2014
Max BC CSI: 0.465
Bearings B & I are a rigid surface.
Bearing B requires a seat plate.
S
Spacing: 24.0 "
C&C Dist a: ft
Rep Factors Used: Yes
Max Web CSI: 0.996
dwa
Loc. from endwall: not in 6.5D ft
�/RT:20(0)/10(0)
Mfg Specked Camber.
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18
Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:1.60
WAVE, HS
VIEW Ver. 18.02.01A.0205.19
A - B 44 0 E - F 3134 -4286
Lumber
B-C 2576 -3450 F-G 2616 -3611
Value Set: 13B (Effective 6/1/2013)
C - D 2423 - 3285 G - H 1094 -1564
D - E 2736 -3646
Top chord 2x4 SP M-31 :T1 2x4 SP #2:
Bot chord 2x4 SP M31
Webs 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Lumber value set "138" uses design values
Chords Tens.Comp. Chords Tens. Comp.
approved 1/30/2013 by ALSC
B - P 3132 -2587 M - L 4180 -3147
P - O 2904 -2316 L - K 4180 -3147
Loading
O-N 2904 -2316 K-J 2861 -2190
Bottom chord checked for 10.00 psf non -concurrent
N - M 4218 - 3232 J -1 17 -22
Ike load.
Purlins
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
C - P 293 -157 F - K 726 -776
P - D 287 -48 K - G 1023 -580
Wind
D-N 1013 -613 G-J 1497 -1771
Right end vertical not exposed to wind pressure.
N - E 715 -781 J - H 2O48 -1420
E - M 230 - 68 H -1 1203 -1538
M - F 255 -59
a division of
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWNG!
IT- FURNISH THIS DRAW NG TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Im 1,ortorrI
acceptance
any structure
rtal notes page an
e to build the 3670 COMMERCE CENTER
cover ppa� e. SEBRING, FL 33870
The sUit2brhty (863)385-8242
Job Number: 91191
Ply: 2
SEQN: 26411 / T55 / HIPM
/N&A CONSTRUCTION /JURADO/COD /KCD
Qty: 1
FROM:
DRW:
Truss Label: A25
Wgt: 616.0 Ibs
.. / ... 05/22/2020
2 Complete Trusses Required
34'11-1/8"
@=10DX10 @=1EX10 @=1FX10
512
C___
O _ G
T1
�W2�� �WM2
T
W2
=5X6(A1)B
W2 W3 D
`° "
A
1
P B1 O N M 82 L K J
B2 I H
,F2X4=7X6=4X6 =3X4 =H0710 =4X4
=-4X10 105X14
SEAT PLATE REQ.
AL 41'11-1/8"
Loading Criteria (psf) Wind Criteria Snow Criteria (P9,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Sid: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udell U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph Pf: NA Ce: NA VERT(LL): 0.343 L 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.651 L 769 240
P 3236 /- /- A /1867 A
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.056 H - -
H 3270 A A A 11823 A
Des Ld: 37.00 EXP: DMean Height:15.00 ft HORZ(TL): 0.107 H - -
Wind reactions based on MWFRS
NCBCLL: 0.00 Code / Misc Criteria Creep Factor: 2.0
TCDL: 4.0 psf
P Brg Width = 8.0 Min Req = 1.5
Soffit: O.OD BCDL: 6.0 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.578
H B Width = 3.5 Min Re 1.5
q =
Load Duration:1.25 TPI Sid: 2014 Max BC CSI: 0.315
MWFRS Parallel Dist: 0 to h/2
Bearings P & ui are a rigid surface.
Spacing: 24.0 " C&C Dist a: 4.19 it Rep Factors Used: No Max Web CSI: 0.619
Bearing P requires a seat plate.
Loc. from endwall: NA FT/RT:20(0)/10(0) Mfg Specified Camber.
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:1.60 WAVE,HS MEWVer.18.02.01A.0205.19
A-B 22 -22 D-E 3436 -6330
Lumber
B - C 2136 -3857 E - F 2977 -5501
Value Set: 13B (Effective 611/2013)
C - D 2687 -4987 F - G 1231 -2386
Top chord 2x8 SP 2400f-2.OE :T1 2x4 SP #2:Bot
chord 2x8 SP 2400( 2.0E
Maximum Bot Chord Forces Per PI Ibs
We
Webs 2x4 SP #2
Chords Tens.Com Chords Tens. Comp.
P• P•
Lumber value set "13B" uses design values
B - O 3554 -1957 L - K 6291 -3585
approved 1/30/2013 by ALSC
O - N 3437 -1936 K - J 6291 -3585
N - M 3437 -1936 J -1 4387 -2556
Nailnote
M- L 6105 -3505 I- H 8 -6
Nail Schedule:0.149lx3.25", min. nails
Top Chord:1 Row @12.00" o.c.Bot
Maximum Web Forces Per Ply (Ibs)
o.c.
Chord: 1 Row @4"
We
Webs : 1 Row @ 4" o.c.
o.c.
Webs Tens.Com Webs Tens. Comp.
P• p•
Use equal spacing between rows and stagger nails
O - C 220 -40 E - J 713 -927
in each row to avoid splitting.
C - M 1827 -883 J - F 1305 -493
Loading
M - D 962 -1313 F - I 1553 -2345
#1 hip supports 7-0-0 jacks with no webs. -
D - L 264 0 1- G 2740 -1411L
- E 174 0 G - H 914 -1580
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
`*IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shi ping, installing and bracing. Refer to and follow the latest edition of
Component Safety. Information
BCSI (Building
b TPI and SBCA) for sateiy practices pnor to performing these functions Installers shall provide tempora
bracing er BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathingg and bottom chord shall have a proper
attach6:1 n id ceiling Locations shown forpermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, SCOSTA CORPORATION
as a Appiq plates to each face of ttruss and as shown above and on the Join�etails, unless noted Defer to
.plicapgle. position otherwise.
drawings 9 b0A Z for standard plate positions.
WOOD STEEL oR TIMBER
ROOF bR FLOOR TRUSSES
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this dravdn ,any failure to build the 3670 COMMERCE CENTER DRIVE
truss in conformance with ANSI PI 1, or for handling shi�gin installation and bracinct of trusses.A seal on this drrawing or cover page_ SEBRING, FL 33870
listing this drawing,indicates acceptance of profess na engpineerin�gq resp ri tbilit solely for the desir shown.
and �ise of thisawing for any structure is p e responsi ility7of the guildifrg Desigrfer per ANSI1TPI 1 S .2.
•
The sUitabillty (86.3)3gs8242
For more information see thislob's general notes a e and these web sites ALPINE: co • TPI: www • SBCA:
• ICC:
I T &A ussLabel:
/JURADO/COD /KCD I W t 11162 Ibs I FROM:26412 / T99 /HIPS DRW/ 05/22/2020
Job Number 91191 Ply: SEQN:
I- T
7'
a5X8 1112X4 y5X8
C D T2 E
12
T
5 p
Ti W1 W
o' W1 W2 W1 T1
=3X8(A1)B �F=AK 61 J IH B1
1113X5 =7X6 1113X5
�— 2' ---{
Loading Criteria (pst)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 0.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration:1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwail: NA
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x6 SP #2
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
#1 hip supports 7-0-0 jacks with no webs.
Left side jacks have 7-0.0 setback with 0-0-0 cant
and 2-0-0 overhang. End jacks have 7-M setback
with 0-0-0 cant and 2-0-0 overhang. Right side jacks
have 7-0-0 setback with 0-0-0 cant and 0.0-0
overhang.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Snow Criteria (Pg,Pt in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): 0.158 D 999 360
VERT(TL): 0.292 D 890 240
HORZ(LL): 0.040 H - -
HORZ(TL): 0.074 H - -
Creep Factor: 2.0
Max TC CSI: 0.763
Max BC CSI: 0.735
Max Web CSI: 0.146
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
2' --
fl
M
v
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
K 1703 A A
/- /1014 /-
F 1708 A /-
!- /1018 /-
Wind reactions based on MWFRS
K Brg Width = 8.0
Min Req = 2.0
F Brg Width = 8.0
Min Req = 2.0
Bearings K & F are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A-B 44 -44
D-E 1992 -35M
B - C 1958 -3475
E - F 1968 -3485
C - D 1992 -3565
F - G 44 -44
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - J 3150 -1748 I - H 3193 -1767
J-1 3183-1757 H-F 3160 -1758
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - J 636 -165 I - E 459 -276
C -1 471 -288 H - E 647 -177
D -1 446 -430
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT"" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
7uire extreme care in fabricatingp handlin ship Ing, installing.and bracing. Refer to and follow the latest edition of BCSI (Building
t Safely Information b TPI and SBCA) for safety practices poor to performing these functions. Installers shall rovide tempo
ra
BCSI. Unless noted ohervuise,top chord shall have propedy attached structural sheathin� and bottom chord sfPall have a pro
�e Ir y
iiid ceilingg. Locations shown forpennanent lateral restraint of webs shall have braving rns ailed per BCSI sections B3, 67 or 10, SCOSTA CORPORATION
e._ Apply plates to each face, of truss and posaioIn as shown above and on the Joint Details, unless noted othervuise. I�efer to WOOD STEEL oR TIMBER
a division of
any
R6OFbRFLOORTR6S5ES
failure to build the 3670 COMMERCE CENTER DRII
or cover Cage SEBRING, FL 33870
II . The s t bility (863)385-8242
Job Number. 91191 Ply: 1 SEQN: 26381 / 75 / HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: B2 I Wgt: 106A Ibs / ... 05/22/2020
9' 4 -}, 9'
i
1=
Loading Criteria (pso
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
D
Des Ld: 37.00
Mea
Mean Height:15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwali: not in 9.00 It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP M31 :T2 2x4 SP #2:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
M
Def11CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): 0.043 H 999 360
VERT(TL): 0.077 H 999 240
HORZ(LL): 0.016 G - -
HORZ(TL): 0.029 G - -
Creep Factor: 2.0
Max TC CSI: 0.582
Max BC CSI: 0.238
Max Web CSI: 0.066
Mfg Specified Camber.
VIEW Ver. 18.02.01A.0205.19
11
m
m
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc _R+ / R- / Rh / Rw / U / RL
B 940 /- /-
1618 /570 228
E 940 /- /-
/618 /570 /-
Wind reactions based on MWFRS
B Big Width = 8.0
Min Req = 1.5
E Brg Width = 8.0
Min Req = 1.5
Bearings B & E are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
D- E 967 -1446
B- C 968 -1446
E- F 44 0
C - D 973 -1157
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - I 1250 -633 H - G 1144 -685
1- H 1144 -635 G - E 1250 -682
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
I-C 293 0 H-D 184 -116
C-H 183 -116 D-G 293 0
'"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"IMPORTANT`* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qauire extreme care in fabricatingp handling; shi ing, installing,and bracing. Referto and followthe latest edition of BCSI (Building
f Safety Information b PI and'SBCA) for sate�j/ practices poor to performing these functions Installers shall provide temporarg
SCSI., Unless noted o�herw. top chord shall have properly attached structural sheathing and bottom chord shall have a pro nY
�Id ceiling Locations shown forpermanent lateral restraint of webs shall have bracin mslalled per BCSI sections 63, 67 orSCOSTA CORPORATION
e. Apply plates to each face of truss and position as shown above and on the Join�etails, unless noted otherwise. f7efer to woOD sTEEL oR TIM6ER
60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Of
any
failure to buiilplddagthe 3670 COMMERCE CENTER DRII
1%. Theesbitbbility sE(B�� 8,5-8 42
Job Number: 91191 Ply: SEQN:
/N&A CONSTRUCTION /JURADO/COD /KCD I 1I FROM26382 / T86 /HIPS DRW:
Wgt Truss Label: B3 Ibs ... / ... 05122/2020
10'11-1/4"
10'7-5/8"
SEAT PLATE REQ. SEAT PLATE REQ.
21'83/8"
�--- 2 ---
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT. NA
PP Deflection in loc Udell L/#
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
VERT(I-Q: 0.065 1 999 360
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.120 1 999 240
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.023 G - -
Des Ld: 37.00
EXP: D
Mean Height: 15.00It
HORZ(TL): 0.043 G -
NCBCLL: 10.00
TCDL: 4.0 psf
Code / Misc Criteria
Creep Factor: 2.0
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.644
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
TPI Sid: 2014
Max BC CSI: 0.602
Spacing: 24.0 "
C&C Dist a: 3.00 It
Rep Factors Used: Yes
Max Web CSI: 0.152
Loc. from endwall: not in 9.00 It
FT/RT:20(0)/10(0)
Mfg Specified Camber.
GCpi: 0.18
Plate Type(s):
VIEW Ver. 18.02.01A.0205.19
Wind Duration:1.60
WAVE
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
9D
s�.
rn
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 935 /- A /602 /567 )229
F 809 /- A /449 /464 A
Wind reactions based on MWFRS
B Big Width = 8.0 Min Req = 1.5
F Big Width = 4.4 Min Req = 1.5
Bearings B & F are a rigid surface.
Bearings B & F require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 D- E 1022 -1339
B - C 1064 -1536 E - F 1089 -1510
C - D 995 -1362
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp: Chords Tens. Comp.
B -1 1368 -895 H - G 932 -526
I - H 932 -526 G - F 1340 -892
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C -1 36B -275 D - G 424 -260
I - D 457 -254 G - E 369 -261
"WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fI
bricatingg handlin shi pIng, installing,and bracing. Refertoand followthe latest edition of BCSI (BuildingSaety Inforation bTPI and'SBCA)orsaeppracespoor toperforming tj�ese functions. Installers shall provide tempoBSnless noteherwtpchord shallhave proedyached struural) sheathin and bottomchord shallhaveaproeryrly�Id ceiling. Locationshown forpermanent lateral restraint of webs shall have bracin ms�alled per BCSI sections 63, 67 or B10'
i e. Apply lates to each face of truss and position as shown above and on the JoinfgDetails, unless noted otherwise. Defer to
60A-Z for sV ndard plate positions.
of
III 1,, or for h
acceptance
any structure
failure to build the 3670 COMMERCE CENTER
or cover a e, , SEBRING, FL 33870
1. The s I blllty (863)385-8242
IJob Number: 91 f91 Ply: 1 SEON: 26383 / T85 /HIPS
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW.
Truss Label: B4 Wgt: 100.8 Ibs / ... 05/22/2020
1
is
SEAT PLATE REQ.
F-- 2' ---�
9' + 4' 8'8-3/8"
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Sid: ASCE 7-10
TCDL: 7.00 Speed: 159 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
Des Ld: 37.00 EXP: D
Mean Height:15.00 ft
NCBCLL: 10.00 TCDL: 4.0 psf
Soffit: 0.00 BCDL: 6.0 psf
Load Duration:1.25 MWFRS Parallel Dist: h to 2h
Spacing: 24.0 " C&C Dist a: 3.00 It
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set:13B (Effective 6/1/2013)
Top chord 2x4 SP M31 :T2 2x4 SP #2:
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
21'8-3/8"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Deft/CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): 0.043 G 999 360
VERT(TL): 0.078 G 999 240
HORZ(LL): 0.021 F - -
HORZ(rL): 0.039 F - -
Creep Factor: 2.0
Max TC CSI: 0.607
Max BC CSI: 0.551
Max Web CSI: 0.065
Mfg Specified Camber.
VIEW Ver: 18.02.01A.0205.19
=3X4(A1)
s�
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 935 /- P /611 /349 /195
E 809 P P /458 /280 P
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
E Brg Width = 3.5 Min Req = 1.5
Bearings B & E are a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 C- D 1025 -1144
B - C 1002 -1429 D - E 994 -1404
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - H 1235 -781 G - F 1124 -760
H-G 1134 -787 F-E 1211 -751
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
H- C 288 0 G- D 205 -12B
C-G 194 -127 D-F 264 0
"'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabricating handlin shi Ing, installing,and bracing. Referto and followthe latest edition of BCSI (Building
t Safety Information b TPI end SBCA) for sate y practices poor to performing these functions. Installers shall provide temporary
r BCSI Un ess notes o hennn. top chord shall have properly attached st aural sheathing and bottom chord shall have a properly
qid ceiling. Locations shown for permanent lateral restraint of webs shall have bracinc�msZalled per BCSI sections 63, B7 or B10, SCOSTA CORPORATION
e. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Defer to WOOD STEEL OR TIMBER
60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Of
rTPI 1, or for h
r
acce tance
any structure
failure to build the 3670 COMMERCE CENTER DRI\
or cover a SEBRING, FL 33870
1. The s ! bility (863)385-8242
Job Number 91191 Ply: SEQN:
Truss
CONSTRUCTION CTION /JURADO/COD /KCD I QQj: 1113.4 Ibs I FROM26413 / T87 /HIPS I DRW. 05/22/2020 I
V--- 7'
U8-3/8" -{
--5Xa QIZX4 O =4 E U
C D
T 12
6 W1 W
T1 3
W1 W2 W1
1 F
=4X16(B3) B
A J 81 1 H G 62
1113X8 =BX8 1112X4
SEAT PLATE REQ.
21'8-318"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 61112013)
Top chord 2x4 SP #2 :T1 2x4 SP M31:
Bot chord 2x6 SP M-14
Webs 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 byALSC
Special Loads
--(Lumber Dur.Fac =1.25 / Plate Dur.Fac=1.25)
TC� From 55 plf at -2.11 to
55 plf at
7.00
TC: From 28 plf at 7.00 to
28 plf at
8.83
TC: From 55 plf at 8.83 to
55 plf at
21.70
BC: From 20 plf at 0.00 to
20 plf at
7.03
BC: From 10 pit at 7.03 to
10 ptf at
8.83
BC: From 20 plf at 8.83 to
20 plf at
21.70
TC: 427 lb Conc. Load at 7.03
BC: 423 lb Conc. Load at 7.03
BC: 843 lb Conc. Load at 8.83
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of dg!d ceiling provide lateral bracing to brace
BC @ 24" OC
Snow Criteria (Pg,Pt in PSF)
Pg: NA Ct: NA CAT. W
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Varies b
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
DeflICSI Criteria
PP Deflection in loc Udell U#
VERT(LL): 0.140 D 999 360
VERT(rL): 0.259. D 993 240
HORZ(LL): 0.032 G - -
HORZ(TL): 0.059 G - -
Creep Factor: 2.0
Max TC CSI: 0.624
Max BC CSI: 0.847
lddRM eb CSI: 0.296
Mfg Specked Camber.
=3X8(A1)
a
m
6
1
♦ Maximum Reactions (ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
J 1969 /- A /- /1146 /-
F 1400 /- /- /- /777 /-
Wind reactions based on MWFRS
J Brg Width = 8.0 Min Req = 2.0
F Brg Width = 3.5 Min Req = 1.7
Bearings J & F are a rigid surface.
Bearing J requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01A.0205.19 J A- B 44 -44 D - E 1997 -3694
B - C 2313 -4205 E - F 1631 -2912
C - D 1998 -3694
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - I 3821 -2072 H - G 2628 -143B
I - H 3874 -2085 G - F 2626 -1442
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C -1 1046 -260 H - E 1311 -688
C- H 109 -222 G- E 245 0
D-H 176 -163
"'WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
JT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
care in faIt
ting handlin shi rng, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
mat
b nd SBCA)or to y pctiestperfrminthesfunctionstlshall provide teponotedse,top chord shad have propedattached structural sheathingq and bottom chord shallhave aproxahonsorermanent lateral restraint of webs shall have bracinggmslalled per BCSI sections B3, 67 or 610, SCOSTAatestoeace of truss and posit!on as shown above and on the JoinCDetails, unless noted the. Defer to WOOD STEEL OR TIMBER
ndard plate positions. ROOF bR FLOOR TRUSSES
Of
any
failure to build the 3670 COMMERCE CENTER DRI)
iQ �r TheesUit2elfty S (863 8SF8L242870
Job Number: 91191 Ply:1 SEQN: 26414 / T21 / HIPM
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: C1 Wgt: 75.6IN / ... 05/22/2020
r T 9' _I
T T
W1 W1 M
3X5(A1) B
y 1
A 9H 5 1113X6 F
1112X4 =5X8 �
SEAT PLATE REQ.
16'
Loading Criteria (p4 Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.DD Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT. NA PP Deflection in loc Udefl L/#
Gravity Non -Gravity
Speed: 159 mph
TCDL: 7.00 P P
Pf: NA Ce: NA
VERT(LL): 0.061 H 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.115 H 999 240
B 1178 !- A !- /718 A
BCDL: 10.00 Risk Category: II
Snow Duration: NA
HORZ(LL): 0.018 F - -
F 1286 /- A A /712 A
Des Ld: EXP: D 37.OD
HORZ(TL): 0.034 F - -
Wind reactions based on MWFRS
Mean Height: 15.00 ft
NCBCLL: 0.00 TCDL: 4.0 psf
4.0
Code / Misc Criteria
Creep Factor: 2.0
B B Width = 8.0 Min Re 1.5
r9 q =
Soffit: 0.00 BCDL: P sf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.576
F Brg Width = - Min Req = -
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h!2
TPI Std: 2014
Max BC CSI: 0.690
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Spacing: 24.0 " C&C Dist a: 3.00 ft
Rep Factors Used: No
Max Web CSI: 0.459
Loc, from endwall: NA
FT/RT:20(0)/10(0)
Mfg Specified Camber.
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18
Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:1.60
WAVE
VIEW Ver. 18.02.01A.0205.19
A- B 44 -44 C- D 844 -1521
Lumber
B-C 1179 -2083 D-E 844 -1521
Value Set: 13B (Effective 611/2013)
Top chord 2x4 SP #2
Maximum Bot Chord Forces Per Ply (Ibs)
Bot chord 2x4 SP #2
Chords Tens.Comp. Chords Tens. Comp.
Webs 2x4 SP #2
B - H 1859 -1023 G - F 15 -8
Lumber value set "13B" uses design values
H - G 1889 -1030
approved 1/30/2013 by ALSC
Loading
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
#1 hip supports 7-0-0 jacks with no webs.
Left side jacks have 7-0-0 setback with 0-0-0 cant
C - H 604 -141 G - E 1803 -1001
and 2-1-6 overhang. End jacks have 7-M setback
C - G 222 -440 E - F 757 -1198
with 0-0-0 cant and 2-1-6 overhang. Right side jacks
D - G 564 -553
have 0-0-0 setback with 0-0-0 cant and 0-0-0
overhang.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at right end of
truss for 1286 Ibs.
*"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin_q shi Ing, installing, and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety. Information b TPI an g SBCA) or safely practices pnor to performing these functions. Installer provide temporary
braci�g�er BCSI. Unless noted o hervvise,top chord shall have property attached structural sheathing and bottom c ord shall have a proge
attac e ri id ce!ling. Locations shown forpermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 10,
as applica e. Apply lates to each face of truss and position as shown above and on the Joinf�etails, unless noted otherwise. f?efer to
draWngs 60A-Z for standard plate positions.
Alpine, a division of ITW Building Components Grout) Inc. shall not be responsible for anv deviation from this drawinn.anv failure to build the
3670 COMMERCE CENTER
SEBRING, FL 33870
(863)385-8242
II vi 1, or Torn
acceptance
any sructure
or cover page
1%. The sgbility
Job Number 9f191 Ply:
M8A CLaONNSTRUCTION /JURADO/COD /KCD bel: C2 I Qtyt?219.8 Ibs FROM26418 / T4 / HIPM I DRW.Truss 05/22/2020
I
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
2 Complete Trusses Required
8'2" iT10"
SEAT PLATE REQ.
16'
�- Z --1
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP M•31 :T2 2x4 SP #2:
Bot chord 2x8 SP 2400f--2.0E
Webs 2x4 SP #2 05 2x4 SP M31:
:W6 2x6 SP #2:
Lumber value set 1313" uses design values
approved 1/30/2013 by ALSC
Nailnote
Nail Schedule:0.148"x3.25", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @ 3.00" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
--(Lumber Dur.Fac =1.25 / Plate Dur.Fac =1.25)
TC: From 55 pif at -2.11 to 55 pff at 7.14
TC: From 28 plf at 7.14 to 28 pif at 9.06
TC: From 55 pif at 9.06 to 55 pif at 16.00
BC: From 20 pif at 0.00 to 20 pif at 7.14
BC: From 10 plf at 7.14 to 10 pif at 16.00
BC: 3585 lb Conc. Load at 7.14
BC: 1720 lb Conc. Load at 9.06,11.06,13.06,16.06
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
PF. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.106 J 999 360
VERT(TL): 0.195 J 973 240
HORZ(LL): 0.018 G - -
HORZ(TL): 0.034 G • - -
Creep Factor: 2.0
Max TC CSI: 0.397
Max BC CSI: 0.324
Max Web CSI: 0.580
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
Additional Notes
Provide hanger or special connection at right end of
truss for 7249 Ibs.
Y
c2
c�
ao
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
K 4391 /- /- /- /2511 /-
G 7249 /- /- /- /3731 A
Wind reactions based on MWFRS
K Brg Width = 8.0 Min Req = 1.8
G Brg Width = - Min Req = -
Bearing K is a rigid surface.
Bearing K requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 22 -22 D-E 1813 -3341
B - C 2887 -5165 E - F 1813 -3341
C - D 2631 - 4711
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - J 4738 -2635 I - H 4356 -2423
J -1 4702 -2617 H - G 26 -14
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
J - C
1164 -586
E - H
102 -80
C -1
625 -1114
H - F
4329 -2348
D - I
2571 -1474
F - G
1566 -2845
D - H
795 -1324
"WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
-IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabricatingg handlin ship mg, installing and bracing. Refer to and follow the latest edition of BCSI (Building
it Safety Informat!on b TPI and'SBCA) for safe y practices prior to performing these functions. Installers shall provide tempora
r BCSI.. Unless noted o herwise,top chord shall have propedy attached structural sheathin and bottom chord shall have 7 prop eryrly
44id ce!IIng Locations shown torpa m in nt lateral restPrit of webs shall have brae. ic�n ailed per BCSI sections 63, 67 or 610, SCOSTA CORPORATION
Apply plates to each face_ of truss and position as shown above and on the JoinCDetails. unless noted othenruise. E�efer to WOOD STEEL OR TIMBER
of
TPI 1, or for h
acceptance
any structure
966irtR FLOOR TRUSSES
failure to build the 3670 COMMERCE CENTER DRB
g or cover a e SEBRING, FL 33870
in. The s0!t3bihty (863)385-8242
Job Number: 91191 Ply: 1 SEQN: 26387 / T6 / GABL
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: D1 I Wgt: 70.0 Ibs / ... 05/22/2020
Loading Criteria (pso
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
h
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height: 15.00It
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C$C Dist a: 3.00 It
Loc. from endwall: Any
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 611/2013)
Top chord 2x4 SP #2
Bat chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Plating Notes
All plates are 2X4 except as noted.
Loading
Bottom'chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
See standard gable detail for more requirements.
99-5/8" i8'95/8"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
PLATING NOTES
All plates are 2X4 except as noted.
D=4X4
DeflICS1 Criteria
PP Deflection in loc Udell L/#
VERT(LL): 0.011 L 999 360
VERT(TL): 0.021 L 999 240
HORZ(LL): 0.004 H - -
HORZ(TL): 0.007 L -
Creep Factor: 2.0
Max TC CSI: 0.326
Max BC CSI: 0.292
Max Web CSI: 0.074
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
*`WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
*`IMPORTANT** FURNISH THIS DRAWNG TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Of
♦ Maximum Reactions (Ibs), or'=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A' 78 P A /37 59 /8
Wind reactions based on MWFRS
A Brg Width = 204 Min Req = -
Bearing A is a rigid surface.
Bearing A requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 137 -169 D-E 130 0
B-C 105 -35 E-F 105 -35
C-D 130 0 F-G 137 -169
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - L 227 -99 J -1 245 -105
L - K 242 -104 I - H 242 -104
K-J 245 -105 H-G 227 -99
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp.
B - L 449 -209 I - E 303 -86
C - K 303 -85 H - F 449 -209
D-J 131 -176
SCOSTA CORPORATION
ROOFD ?R FLOORRTRUSS�ES
failure to bor uiilldgthe
3670 COMMERCE CENTER DRD
1%. Theesu1 bility S (863)3G85F-8234'2
Job Number. 91191 Ply:1 SEQN: 26388 / T7 / COMN I I
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 2 FROM: DRW.
Truss Label: D2 I Wgt: 84.0 Ibs I / ... 05/22/2020
Loading Criteria (pso
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
Lumber
819-518" 8'9-5/8"
E=4X4
7SEATI SATE REQ. SEAT PWT R6..EQ.
I A 16W
�--2' 1,177-1/4"
Wind Criteria
Wind Sid: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height: 15.00 it
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
:Lt Slider 2x4 SP #2: BLOCK LENGTH = 1.91 T
:Rt Slider 2x4 SP #2: BLOCK LENGTH = 1.91T
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Snow Criteria (Pg,Pl in PSF)
Pg: NA Ct: NA CAT: W
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): 0.038 J 999 360
VERT(TL): 0.067 J 999 240
HORZ(LL): 0.017 C - -
HORZ(TL): 0.022 G - -
Creep Factor: 2.0
Max TC CSI: 0.690
Max BC CSI: 0.616
Max Web CSI: 0.357
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
2' --�
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 800 /- /- 1563 /475 /225
K 770 /- /- /536 /459 P
Wind reactions based on MWFRS
B Big Width = 8.0 Min Req = 1.5
K Brg Width = 8.0 Min Req = 1.5
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 303 -996 D - E 457 -758
H -1 45 0 E - F 476 -759
A-B 45 0 F-G 619 -954
C - D 585 -908 G - H 193 -926
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - J 804 -336 J - H 865 -410
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - C 1425 -1025 J - F 280 -226
D-J 212 -151 G-H 1368 -866
E - J 362 -61
"'WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"IMPORTANT"" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricatingp handlin ship�ng, installing,
and bracing. Referto and follow the latest edition of BCSI (Building
Safety Information b TPI and $BCA) for safe practices poor to performing these functions.Installrshall provide temporaBSI. United 0herwisetop chord shallvepropertyachedstructuralsheathingQ nd bottmcord shll have aproppee;id ceilinLtionshownfopermanentlatel restraint of webs shall have bracingg�insTalled per BCSI sections B3, 67 or 610, SCOSTA CORPORATION
le. AD.Tv Dlates to each face of truss and D.ai.n as shown above and on the JoinfDetails. unless noted otherwise. I�efer to WOOD sTEEL OR TIMBER
of
any
961TV61W FLOOR TRUSSES
failure to buildthe3670 COMMERCE CENTER DRI1
Ig or The cover Up
S (863)385 8242870
{ Job Number. 91191 Ply:1 SEQN: 26389 / T8 / COMN
I/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW.
Truss Label: D3 I Wgt: 78.4 lbs / ... 05/22/2020
Loading Criteria (pq
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
8'9-5/8" i V95/8"
D=4X4
7LLATE REQ. SEAT PI ATA0BQ.
fI 16,8„ 3 Y
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 It
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
:Lt Slider 2x4 SP #2: BLOCK LENGTH = 1.917'
:Rt Slider 2x4 SP #2: BLOCK LENGTH = 1.91T
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
17'7-1/4"
Snow Criteria (Pg,Pt in PSF)
DeflICSI Criteria
♦ Maximum Reactions (Ibs)
Pg: NA Ct: NA CAT- NA
PP Deflection in loc Udell L/#
Gravity Non -Gravity
Pf: NA Ce: NA
VERT(LL): 0.031 H 999 360
Loc R+ / R- / Rh / Rw / U / RL
Lu: NA Cs: NA
VERT(rL): 0.059 H 999 240
A 676 A A /398 /381 /148
Snow Duration: NA
HORZ(LL): 0.012 H - -
1 649 A /- /374 /369 !-
HORZ(TL): 0.023 H - -
Wind reactions based on MWFRS
Code / Misc Criteria
Creep Factor: 2.0
A Big Width = 8.0 Min Req = 1.5
Bldg Code: FBC 2017 RES
Max TC CSI: 0.254
1 Big Width = 8.0 Min Req = 1.5
TPI Std: 2014
Max BC CSI:. 0.634
Bearings A & I are a rigid surface.
Rep Factors Used: Yes
Max Web CSI: 0.264
Bearings A & I require a seat plate.
FT/RT:20(0)/10(0)
Mfg Specked Camber.
Maximum Top Chord Forces Per Ply (Ibs)
Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
WAVE
VIEW Ver: 18.02.01A.0205.19
A- B 0 -359 D - E 621 -800
B - C 776 -958 E - F 827 -1008
C-D 612 -797 F-G 0 -595
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-H 854 -613 H-G 917 -660
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
A - B 1038 -839 H - E 349 -241
C-H 291 -169 F-I 1017 -694
D-H 381 -154
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
vqire extreme care in fabricatingq handling shi pIng, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information b TPI and'SBCA) for' sate, practices prior to performing these functions Installers shall provide temporary `
r BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proppeerty
,iid ceiling Locations shown forpermanent lateral restraint of webs shall have bracinc(L�mslalled per BCSI sections B3, 67 or 610, SCOSTA CORPORATION
e. Appijr plates to each face of truss and position as shown above and on the JoinTDetails, unless noted otherwise. f7efer to WOOD STEEL OR TIMBER
60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Vision of ITW Buildinl1Components Group Inc. shall not be responsible for any deviation from this drawinq,any failure to build the 3670 COMMERCE CENTER DRR
rfonnance with ANSI PI 1, or for handling shirgin,lq installation and bracing of tmsses.A seal on this ttTTrawin or cover page SEBRING, FL 33870
drawin ,indicates acceptance of r less na ' en rneerin res onslbrlrt sotel for the desi n s ow The s i bilit
�f awl z indicates .... �fr...�*..re.e�......�:�.:rmpine rigg. r. sp n.ibility sol v or the � ion y (863)385-8242
Job Number: 01191 1 Ply: 1 SEQN: 26390 / T23 / SPEC I I
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 2 FROM: DRW:
Truss Label: D4 I Wgt: 72.8 Ibs / ... 05/22/2020
�t
III
T
-3Y
SEAT PLATE REQ.
Loading Criteria (pst)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 It
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
:Lt Wedge 2x4 SP #2::Rt Wedge 2x4 SP #2:
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
8'1-15116' - I - 82-1 /16" -I
Snow Criteria (Pg,Pr in PSF)
Pg: NA Ct: NA CAT: W
PF. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
C=4X4
32)(R)
G
SEAT PLATE REQ.
16'4"
DefUCSI Criteria
PP Deflection in loc Udell U#
VERT(LL): -0.048 F 999 360
VERT(TL): 0.082 F 999 240
HORZ(LL): -0.023 F - -
HORZ(TL): 0.034 F - -
Creep Factor: 2.0
Max TC CSI: 0.345
Max BC CSI: 0.674
Max Web CSI: 0.091
Mfg Specified Camber -
VIEW Ver. 18.02.01A.0205.19
*"WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
""IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING l
as snown aoove ana on
a division of
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 614 /- /- /336 /352 /138
G 614 /- /- /337 1352 /-
Wind reactions based on MWFRS
A Brg Width = 8.0 Min Req = 1.5
G Big Width = 8.0 Min Req = 1.5
Bearings A & G are a rigid surface.
Bearings A & G require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 871 -1062 C - D 645 -821
B - C 645 -821 D - E 872 -1064
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-F 932 -712 F-E 933 -713
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - F 359 -233 F - D 351 -235
C - F 404 -172
INSTALLERS
ow the latest edition of BCSI (Building
is. Installers shall provide tempora�
ind bottom chord shall have a pro r
led per BCSI sections B3, B7 or Biro,
s, unless noted Otherwise. kefer to
SCOSTA CORPORATION
WOOD STEEL OR TIMBER
ROOF bR FLOOR TRUSSES
n this drawing,any failure to build the
this iawing
3670 COMMERCE CENTER DRIVE
eal on or cover page
,r the design shown. The sUltability
SEBRING, FL 33870
(863)385-8242
I T &A CLaONNSTRU,CTION MURADO/COD /KCD I Qty: 40.6 Ibs I FROM26405 / T33 /HIP DRW.
/ ... 05/22/2020
Ifa
T
M
-
N
.0
M
t!')
W2
2X4(A1) B
W1
T
3-3/4"
A 61 G =3X4 F E
1112X4
�-- 2'9-15/16"
Loading Criteria (pst)
Wind Criteria
Snow Criteria (Pg,PP in PSF)
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: W
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean. Height:15.00 itNCBCLL:
0.00
TCDL: 4.0 psi
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration:1.25
MWFRS Parallel Dist: 0 to h/2
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Factors Used: No
Loc. from endwall: NA
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration:1.60
WAVE
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP M31
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumber value set "136" uses design values
approved 1/3012013 byALSC
Loading
Hipjack supports 7-0-0 setback jacks with no webs.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
a division of
910-13/16"
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc Udefl L/#
Gravity Non -Gravity
VERT(LL): 0.184 F 636 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(TL): 0.332 F 353 240
B 497 /- A /- 1344 /-
HORZ(LL): 0.043 C - -
E 296 P /0 P /83 /0
HORZ(TL): 0.077 C - -
D 255 /- /- P /227 !-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.324
B Brg Width =11.3 Min Req = 1.5
Max BC CSI: 0.668
E Brg Width =1.5 Min Req = -
Max Web CSI: 0.105
D Brg Width =1.5 Min Req = -
Bearing B is a rigid surface.
Mfg Specked Camber.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 18.02.01A.0205.19
A-B 47 -40 C-D 72 -64
B - C 339 -601
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-G 541 -296 F-E 0 0
G-F 513 -291
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
G - C 460 -95 C - F 433 -756
'"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
IT- FURNISH THIS DRAWNG TO ALL CONTRACTORS INCLUDING THE INSTALLERS
any
'sualm or wens snau nave Dracingq�staneo per tl,
as shown above and on the Joini etails, unless
In of BCSI (Building
mpro ryrly
provide tempos14�Dl�
nail have a s B3, B7 or 131O SCOSTA CORPORATION
rerwise. Defer to WOOD STEEL OR TIMBER
ROOF bR FLOOR TRUSSES
failure to build the 3670 COMMERCE CENTER DRIVE
Ior cover e" , SEBRING, FL 33870
1%. The s i blllty (863)385-8242
Job Number. 91191 Ply: 1 SEQN: 26406 / T18 /HIP_
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM. DRW:
Truss Label: CJ9 Wgt: 32.2 Ibs .. / ... 05/22/2020
12
3.54 p
2X4(A1) B
3
A
SEAT PLATE REQ.
�--- 2'9-15/16",
Loading Criteria (pst)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height: 15.00 It
NCBCLL: 0.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration:1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 It
Loc. from endwall: NA
GCpi: 0.18
Wind Duration:1.60
Top chord 2x4 SP M31
Bot chord 2x4 SP M-31
Loading
Hipjack supports 6-4-0 setback jacks with no webs.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (3) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
8'11-1/2"
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udell U#
Pf: NA Ce: NA
VERT(LL): NA
Lu: NA Cs: NA
VERT(TL): NA
Snow Duration: NA
HORZ(LL): 0.018 D - -
HORZ(TL): 0.033 D - -
Code / Misc Criteria
Creep Factor: 2.0
Bldg Code: FBC 2017 RES
Max TC CSI: 0.524
TPI Std: 2014
Max BC CSI: 0.261
Rep Factors Used: No
Max Web CSI: 0.000
FT/RT:20(0)/10(0)
Mfg Specked Camber.
Plate Type(s):
WAVE
i VIEW Ver: 18.02.01A.0205.19
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
C
Y
1
n
1
d)
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 440 /- !- /- /310 !-
D 132 A A /48 /- !-
C 308 A A /- /293 !-
Wind reactions based on MWFRS
B Big Width =11.3 Min Req = 1.5
D Brg Width =1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 46 -39 B-C 87 -83
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
SCOSTA CORPORATION
WOOD
FeR FLOORRTRUSS S
failure to build the 3670 COMMERCE CENTER DRIVE
I or cover pale SEBRING, FL 33870 -
✓ . The S I bility (863)385-8242
IJob Number 91191
T &A Css LaONSTRU4CTION /JURADO/COD /KCD I W : 118.2 1bs I FROM:26407 / T50 /HIP_ I DRW. �/22/2020 I
12 C
3.54 p
T1
2X4(A1)B 00
3-11 1/- C*
N
A B1 D
1S f,6pLATE REQ.
1- 2'9-15/16" 4'2-15/16"
Loading Criteria (pso
Wind Criteria
Snow Criteria (Pg,Pf in PS17
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: N/
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 0.00
TCDL: 4.0 psf
Code / Misc Criteria
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Factors Used: No
Loc. from endwall: NA
FT/RT:20(0)/10(0)
GCph 0.18
Plate Type(s):
Wind Duration:1.60
WAVE
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 byALSC
Loading
The following trusses need concentrated loads at the
end of their overhangs: 0-0-0 span/setback member
on the 0-1-2 cant side requires 41 Ibs and the 0-0-0
span/setback member on the 0-1-2 cant side requires
41 Ibs.
Sub -fascia beam assumptions: 2-0-0 sub -fascia beam
on the 0-1-2 cantilever side. 2-0-0 sub -fascia beam on
the 0-1-2 cantilever side.
Hipjack supports 3-0-0 setback jacks with 0-1-2
cantilever one face; 0-1-2 cantilever opposite face.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
Defl/CSI Criteria
♦Maximum Reactions (Ibs)
PP Deflection in loc Udefl U#
Gravity Non -Gravity
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
VERT(TL): NA
B 292 /- A A /238 /-
HORZ(LL): 0.006 D
D - /-7 /- 137 A A
HORZ(TL): 0.008 D -
C 27 /- A A 128 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.820
B Brg Width = 9.7 Min Req = 1.5
Max BC CSI: 0.211
D Big Width =1.5 Min Req = -
Max Web CSI: 0.000
C Brg Width =1.5 Min Req = -
Bearing B is a rigid surface.
Mfg Specified Camber.
Bearing B requires a seat plate.
VIEW Ver 18.02,01A,02�i�,19
VIEW Ver. 18.02.01A.0205.19
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 46 -39 B-C 21 -21
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
'"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricatingp handlI shipppIng, !nstalling,and bracing. Referto and followthe latest edition of BCSI (Building
Corriponent Safety. Information b TPI and'SBCA) for safely practices pnor to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathin and bottom chord shall have a pro rly
attached ' id ceiling Locations shown for permanent lateral restraint of webs shall have bracingq� ,, ailed per BCSI sections B3, B7 or B110, SCOSTA CORPORATION
as appl!capgle. Apply plates to each face , of truss and position as shown above and on the JoiIn tails, unless noted otherwise. f2efer to woOD STEEL OR TIMBER
draWngs 16'0A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for anv deviation from this drawina.anv failure to build the 3670 COMMERCE CENTER DRh
I F9 1; or for In acceptance
anystructure
g or cover page SEBRING, FL 33870
in. The spi 9bility (863)385 U42
Job Number: 91191 Ply: 1 SEQN: 26391 / T31 / EJAC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 47 FROM: DRW.
Truss Label: EJ7 I Wgt: 23.8 Ibs .. / ... 05/22/2020
4
Loading Criteria (pst)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
�- 2' 7'
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 R
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 135 (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumbervalue set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
Snow Criteria (Pg,Pl in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Def11CS1 Criteria
PP Deflection in too Udell L/#
VERT(LL): NA
VERT(fl.): NA
HORZ(LL): 0.013 D -
HORZ(TL): 0.023 D -
Creep Factor: 2.0
Max TC CSI: 0.808
Max BC CSI: 0.479
Max Web CSI: 0.000
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
"WARNING' READ AND FOLLOW ALL NOTES ON THIS DRAWING!
""IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
C
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 402 A /- /347 /222 232
D 124 A /- /67 A /-
C 162 A /- 1104 /184 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width =1.5 Min Req = -
C Brg Width =1.5 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 44 0 B-C 62 -148
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D0 0
failure.to buildthe3670 COMMERCE CENTER
�q or TheesUitabilit SEBRING, FL 33870
h y (863)385-8242
Job Number 91191 Ply:
/N&A CONSTRUCTION /JURADO/COD /KCD I Wgt 121.0 Ibs I FROM:26392 / T32 / EJAC DRW.
Truss Label: EJ7A / ... 05/22/2020
Loading Criteria (pst)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
=2X4(A
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set " 136" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
7'
Defl/CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): -0.019 C - -
HORZ(TL): 0.032 C - -
Creep Factor: 2.0
Max TC CSI: 0.875
Max BC CSI: 0.527
Max Web CSI: 0.000
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
"WARNING*" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest i
a division of
any
�sirami or wens snap nave Dracm �nsianeu per b,
as shown above and on the Join etails. unless
A]
T
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 269 /- A 1179 /112 /186
C 127 /- /- 177 /- /-
B 172 /- /- /117 /194 P
Wind reactions based on MWFRS
A Big Width = 8.0 Min Req = 1.5
C Brg Width =1.5 Min Req = -
B Big Width =1.5 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 66 -154
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 0 0
Of
failure to build the 3670 COMMERCE CENTER
or cover a e SEBRING, FL 33870
r . The s i bility (863)385.8242
IJob Number: 91191 Ply:
Truss Label: EJ6 TION /JURADO/COD /KCD I Wgt 1I Ibs I FRO�A:26393 / T57 / EJAC DRW / O5/22/2020
Loading Criteria (pso
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
C
tl
5
T1
ti
04
'
2M(A1) B
T
4"
A
B1 D
SEAT PLATE REQ.
2'
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: h to 2h
CSC Dist a: 3.00 It
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013) '
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
I'Ne load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
Snow Criteria (Pg,PP in PSi7
Pg: NA Ct: NA CAT: W
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
6'4"
DefllCS1 Criteria
PP Deflection in too Udell L/#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.009 D -
HORZ(TL): 0.016 D -
Creep Factor: 2.0
Max TC CSI: 0.683
Max BC CSI: 0.386
Max Web CSI: 0.000
Mfg Specified Camber.
VIEW Ver. 18.02.01A.0205.19
'"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT"" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
any
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 379 /- A /333 /166 /153
D 112 /- A /61 A A
C 144 A A 191 /114 /-
Wind reactions based on MWFRS
B Big Width = 8.0 Min Req = 1.5
D Big Width =1.5 Min Req = -
C Big Width =1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 44 0 B-C 55 -138
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
sns tsa, tsr or tsiu,
kefer
SCOSTA CORPORATION
lerwise. to
WOOD STEEL OR TIMBER
ROOF bR FLOOR TRUSSES
failure to buildthe3670
COMMERCE CENTER DRI1
TheesUI bility
5(8863j 8s8242870
1%.
Job Number 91191 Ply. I
SEQN:
I Tru s ONSTRUC ON /JURADO/COD /KCD I �t 19.6 Ibs I FROM:26394 / T47 / EJAC DRW:
/ ... 05/22/2020
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
=2X4(A
SEAT PLATE REQ.
r 614"
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height: 15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: h to 2h
C$C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/V2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in too Udefl U#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.012 C
HORZ(TL): 0.023 C
Creep Factor: 2.0
Max TC CSI: 0.749
Max BC CSI: 0.443
Max Web CSI: 0.000
Mfg Specked Camber -
VIEW Ver. 18.02.01A.0205.19
B
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 244 !- /- /162 156 /123
C 115 /- /- /70 A A
B 155 /- /- /106 1120 A
Wind reactions based on MWFRS
A Brg Width = 8.0 Min Req = 1.5
C Brg Width =1.5 Min Req = -
B Big Width =1.5 Min Req = -
Bearing A is a rigid surface.
Bearing A requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A - B 60 -144
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 0 0
*'WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricatingp handling sh! ing, installing and bracing. Refer to and follow the latest edition of BCSI (Building
ComponentSafety Information b TPI and'SBCA) for safPe y practices prior to performing these functions. Installers shall provide temporary
bracing er BCSI. Unless notes) o�herwise,top chord shall have properly attached structural sheathingA and bottom chord shall have a pro rly
attacher�dggid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B110, SCOSTA CORPORATIC
as appplicable. AppTyr plates to each face of truss and position as shown above and on the Joint -Details, unless noted otherwa. 17efer to WOOD STEEL OR TIMBI
draVvifrgs 160A-Z for standard plate positions. ROOF bR FLOOR TRUS:
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER
truss in conformance with ANSI, PI 1, orfor handlin shippin ,installation and bracing of trusses.A seal on this drawinqq or cover page SEBRING, FL 33a70
listing this drawinfl, indicates acceptance of �rdgfessi8na? endi eeriIn res r insiibilittr solely for the design showh. The suitability (ga3)3a5-a242
anei Icn of this aunnn fnr nnu a nlrturra is n rn�...,-. K,llit. Otis .r ne ; . — A61elMnl .1 e n
IT &A Cuss LaONSTRUCTION /JURADO/COD /KCD bel: J5 Agt:118.2 Ibs FROM: 26395 / T28 /JACK DRW/ 05122/2020
Job Number. 91191 Ply:
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
Lumber
T
2' 4'10-15/16"
Wind Criteria
Wind Sid: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 it
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration:1.60
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 byALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
Snow Criteria (Pg,PF in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
DefifCSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): NA
VERT(rL): NA
HORZ(LL): 0.005 D - -
HORZ(TL): 0.007 D - -
Creep Factor: 2.0
Max TC CSI: 0.683
Max BC CSI: 0.221
Max Web CSI: 0.000
Mfg Specified Camber.
VIEW Ver. 18.02.01A.0205.19
C
T
d'
1
00
M
N
l
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 332 /- /- 1306 /196 /176
D 84 /- A /46 /- /-
C 104 /- A /61 /121 P
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Big Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 44 0 B-C 40 -112
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabriptin handlingg shippIng, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
f SafetyInformation b TPI an� SBCA) ion safetpy practices poor to performing these functions. Installers shall provide temporary
BCS1., Unl
diness notes o herwise,top chord shall have property attached structural sheathing and bottom chord shall have a pro�erly
aid ceg Locations shown forpermanent lateral restraint of webs shall have bracincLlnstalled per BCSI sections 63, 67 or 10,
r e. Appljr plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to
60A-Z for standard plate positions.
Of
ilure to build the 3670 COMMERCE CENTER
Or cover pope SEBRING, FL 33870
The s 1 bility (863)385-8242
IJob Number: 91191 Pty: 1 SEQN: 26432 / T9 / JACK
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW.
Truss Label: J4 Wgt:17.5 Ibs / ... 05/22/2020
Loading Criteria (pso
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
=2X4(A
T
7-5/16"
i
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 it
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x6 SP #2
Lumber value set "136" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide hanger or special connection at left end of
truss for 164 Ibs.
Provide (2)16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
11) B
4'2-15/16"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/l0(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in too Udell U#
VERT(LL): NA
VERT(rL): NA
HORZ(LL): -0.003 C -
HORZ(TL): 0.004 C -
Creep Factor: 2.0
Max TC CSI: 0.377
Max BC CSI: 0.117
Max Web CSI: 0.000
Mfg Specified Camber.
VIEW Ver. 18.02.01A.0205.19
T
z.
It
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 164 /- /-
/108 /65 /112
C 84 /- A
/52 A A
B 98 /- /-
/66 /117 A
Wind reactions based on
MWFRS
A Brg Width = -
Min Req = -
C Brg Width =1.5
Min Req = -
B Big Width =1.5
Min Req = -
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A - B 38 -107
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 0 0
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabricatingp handlin , ffi
ng, installing,and bracing. Ref
erto and followthe latest edition of BCSI (Building
f Safety Information by TPI end'SBCA) for practices poor to performing these functions Installers shall provide tempora
BCSI., Unless notes olherwise,top chord sve properly attached stmcturaI sheathin and bottom chord shall have a proppeerryly
id ceiling. Locations shown forpermanentl restraint of webs shall have bracinc�ins�alled per BCSI sections B3, 67 or 610, SCOSTA CORPORATION
e. Appiy plates to each face of truss and n as shown above and on the Joint Details, unless noted otherwise. Referto WooD sTEEL oR TIMBER
60A Z for standard plate positions. ROOF bR FLOOR TRUSSES
Of
FI PI 1, or for h
acceptance
anystructure
failure to build
gthe 3670 COMMERCE CENTER DRI'
r1 . Thees 1 bility sE863Ng5-8242 0
IJob Number: 91191 ply: T &A CLaONNSTEJ3CTION /JURADO/COD /KCD Qty:Wyt 112.6 Ibs I FROM: 26397 / T61 /JACK I DRW. 05/22/2020
Loading Criteria (psi)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
3-1516,
SEAT PLATE REQ.
�--- 2' 3'
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height: 15.00It
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: > 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
a division of
Snow Criteria (Pg,Pt in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
5
Defl/CSI Criteria
PP Deflection in foe Udefl L/#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.003 D -
HORZ(TL): 0.004 D - -
Creep Factor: 2.0
Max TC CSI: 0.644
Max BC CSI: 0.165
Max Web CSI: 0.000
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
IN
7�
LO,,T^^
,ram
W
is
T
(0
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 279 /- A /284 /187 /98
D 47 P A /40 /11 /-
C 45 /- A /33 /40 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width =1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 44 0 B-C 17 -60
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
JT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
care in fabricating handl!n shin ing, installing and bracing. Refer to and follow the latest edition of BCSI (Building
mation by TPI pnd'SBCA) fog safe y practices pdor to performing these fugctions. Installers shall provide temporary
s noted oiherwlse,top chord shall have properly attached structural sheathrn and bottom chord shall have a pro rly
)cations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or �10,
ites to each face, of truss and position as shown above and on the Joinmetails, unless noted otherwise. Ikefer to
ndard plate positrons.
' Buildin Components Group Inc. shall not be responsible for any deviation from this drawingy,any failure to build the
h ANSI PI 1, or for handling shippIn , installation and bracing of trusses.A seal on this drawing or cover page
dicates acceptance of prof6sslonalg_ engineering_ FesponsrbJlity solely the design shown. The sOnability
3670 COMMERCE CENTER
SEBRING, FL 33870
(863)385-8242
Job Number. 91191
Piv-
SEQN:
T8A Css LaONNSTRUCTION /JURADO/COD /KCD bel: J3 I �t 112.61bs I 26398 / T29 /JACK I DRW; �/22/2020 I
F]
2'
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height:15.00 ft
NCBCLL: 10.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration:1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set "1315" uses design values
approved 1/30/2013 byALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
C
2' 10-15/16" -{
Snow Criteria (Pg,Pf in PSF)
Def11CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in too Udell L/#
Pf: NA Ce: NA
VERT(LL): NA
Lu: NA Cs: NA
VERT(TL): NA
Snow Duration: NA
HORZ(LL): 0.003 D
HORZ(TL): 0.004 D -
Code / Misc Criteria
Creep Factor: 2.0
Bldg Code: FBC 2017 RES
Max TC CSI: 0.644
TPI Sid: 2014
Max BC CSI: 0.164
Rep Factors Used: Yes
Max Web CSI: 0.000
FT/RT:20(0)/10(0)
Mfg Specked Camber.
Plate Type(s):
WAVE
VIEW Ver. 18.02.01A.0205.19
T
(0
r
�l
M
4
CV
A Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 277 A /-
/283 /189 /122
D 45 A A
/40 /12 /-
C 42 A /-
135 152 A
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
D Big Width = 1.5
Min Req = -
C Brg Width =1.5
Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Pet Ply (Ibsy
Chords Tens.Comp.
Chords Tens. Comp.
A-B 44 0
B-C 16 -57
Maximum Sot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
—WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shi mg, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety. Information b,y TPI and fabricating,
fog safe y practices poor to performing these functions Installers shall provide temporary
bracing er BCSI. Unless noted o herwise,top chord shall have property attached structural sheathingand bottom chord shall have a pro rly
attachesrigid ceiling Locations shown for permanent lateral restraint of webs shall have bracincLrnsalled per BCSI sections B3, 67 or �10,
as applicable. Apply plates to each face of truss and position as shown above and on the Joini"Details, unless noted otherwise. kefer to
dravOings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this draWr q.anv failure to build the
or cover a e
1. The s i bility
3670 COMMERCE CENTER
SEBRING, FL 33870
(863)385-8242
any
Job Number. 91191 Ply: 1 SEQN: 26399 / T30 / JACK I I
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 14 FROM: DRW:
Truss Label: J1 Wgt: 7.0 Ibs / ... 05/22/2020
Loading Criteria (ps0
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
4"
w
Wind Criteria
Wind Sid: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any-
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 611/2013)
Top chord 2x4 SP M31
Bot chord 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
12 C
5 �=2X4(A1)
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Ph NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
R
DefI/CSl Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.427
Max BC CSI: 0.095
Max Web CSI: 0.000
Mfg Specified Camber.
VIEW Ver. 18.02.01A.0205.19
T
8-9/16"
1
T
00
CO
Cfl
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 328 /- /-
/405 /337 170
D 1 /-31 P
/53 /47 /-
C - /-116 /-
/165 /170 P
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Req = 1.5
D Big Width =1.5
Min Req = -
C Brg Width =1.5
Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord -Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 44 0
B - C 240 -67
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
*"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
qquire extreme care in fabricatingg handlingq shi Ing, installing,and bracing. Referto and followthe latest edition of BCSI (Building
f Safety Information byy TPI and'SBCA) for satepty practices pnor to performing these functions. Installers shall provide temporary
r BCSI.. Unless noted oiherwise,top chord shall have property attached structural sheathin and bottom chord shall have a pro rfy
qqid ce!Img. Locations shown forpermanent lateral restraint of webs shall have bracinccLLlnsalled per BCSI sections B3, 67 or �10, SCOSTA CORPORATION
le. Apply plates to each face of truss and position as shown above and on the JoinFDetails, unless noted othervuise. f�efer to WooD STEEL oR TIMBER
60A Z for standard plate positions. ROOF bR FLOOR TRUSSES
a division of
im 7,ortor h
acceptance
any structure
ilure to build the 3670 COMMERCE CENTER DRIB
Or ge,.tyThe tSEBRING, FL 33870
sab(863)385-8242
Job Number: 91191 Ply:1 SEQN: 26400 / T58 / JACK
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 2 FROM: DRW:
Truss Label: J1A Wgt: 7.0 Ibs / ... 05/22/2020
12 C
5=2X4(A1) B- T
T1 av2
3-1T5116" 1 0`0
D c�
A
8
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
I -a— 21
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: If
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP M31
Bot chord 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide (2) 16d toe -nails at top chord.
Provide (2) 16d toe -nails at bottom chord.
SEAT PLATE REQ.
Snow Criteria (Pg,Pf in PSF)
Pg: NA' Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.001 D - -
HORZ(TL): 0.001 D - -
Creep Factor: 2.0
Max TC CSI: 0.427
Max BC CSI: 0.095
Max Web CSI: 0.000
Mfg Specked Camber.
VIEW Ver: 18.02.01A.0205.19
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 328 P /- /406 /337 /70
D 1 /31 /- /53 /48 A
C - /-115 A /164 /169 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width =1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing 8 requires a -seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 44 0 B- C 240 -67
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin sh! Ing, installing. and bracing., Refer to and follow the latest edition of BCSI (Building
Component Safety. Information by TPI and'SBCA) foi safety practices poor to performing these functions. Installers shall provide tempos
bracipgTer BCSI. Unless noted olherwise,top chord shall have property attached structural sheathing and bottom chord shall have a properly
attac a rigid ceiling. Locations shown forpermanent lateral restraint of webs shall have bracinccL�lnstalled per BCSI sections B3, B7 or 10, SCOSTA CORPORATION
as applicable. Apply plates to each face of truss and posdion as shown above and on the Joinf"Details, unless noted otherwise. f�efer to wOoo STEFi oR TIMBER
drawings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Alpine. a division of ITW Buildina Components GmUD Inc. shall not be resoonsihle for anv deviation from this drawino_anv failure to build the 3670 COMMERCE CENT
q or cover page SEBRING FL 33870 DRI\
I1 . The s I bility (863)385-8242
any
IT &A LONNSTRRUCTION /JURADO/COD /KCD I W t 11 Ibs FROM; 26384 / T84 / HIPM DRW ` 05/22/2020
Job Number. 91191 Ply:
abel: B6
Loading -Criteria (pat}
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height:15.00 It
NCBCLL: 10.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.00 It
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set 139" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at left end of
truss for 486 Ibs.
6'6=1 /Z' -f 6'3-1 /8"
= 0^-+
12'9-5/8"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: W
Pf- NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FTlRT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in too Udell L/#
VERT(LL): 0.016 E 999 360
VERT(TL): 0.031 E 999 240
HORZ(LL): 0.008 E - -
HORZ(TL): 0.015 E - -
Creep Factor: 2.0
Max TC CSI: 0.535
Max BC CSI: 0.472
Max Web CSI: 0.483
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
T
r
W1 6
1
D
1113X6
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ ! R- / Rh / Rw / U / RL
A 486 /- A /312 /181 /127
D 476 /- A /261 /265 /-
Wind reactions based on MWFRS
A Big Width = - Min Req = -
D Brg Width = 3.5 Min Req = 1.5
Bearing D is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 674 -753 B - C 614 -634
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-E 647 -649 E-D 15 -15
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - E 337 -125 C - D 502 -432
E - C 682 -660
*"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricating,handling,ship Ing, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Safety. Information by TPI anSBCA) for safe y practices prior to performing tliese functions. Installers shall provide temporary
BCSI. Unless note r3 properly attached structure sheathing and bottom chord shall have a properly
iid ceiling Locations shown forpennanent lateral restraint of webs shall have bracin, 'tailed per BCSI sections B3, B7 or 610,
e. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. kefer to
60A-Z for standard plate positions.
a division of
i vi -i, or Tor n
acceptance
any structure
failure to build the 3670 COMMERCE CENTER
g or cover pa a SEBRING, FL 33870
in. The mllty (863)385.8242
Job Number: 91191 Ply:1 SEQN: 26385 / T49 / HIPM
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: B7 Wgt: 63.0 Ibs .. / ... 05/22/2020
r 8'6-1/2" 4'3-1/6'
Loading. Criteria (pso
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/112013)
Top chord 2x4 SP M31 :T2 2x4 SP #2:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumbervalue set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at left end of
truss for 486 lbs.
ip�
12'9-5/8"
Snow Criteria (Pg,Pr in PSF)
Pg: NA Ct: NA CAT: NP
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Deft/CSI Criteria
PP Deflection in loc Udell L/#
VERT(LL): -0.024 E 999 360
VERT(TL): 0.037 E 999 240
HORZ(LL): -0.013 E - -
HORZ(TL): 0.019 E - -
Creep Factor: 2.0
Max TC CSI: 0.380
Max BC CSI: 0.283
Max Web CSI: 0.236
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
LOG R+ / R- / Rh / Rw / U / RL
A 486 /- /- /323 /156 /166
D 476 /- /- 1286 /254 /-
Wind reactions based on MWFRS
A Brg Width = - Min Req = -
D Brg Width = 3.5 Min Req = 1.5
Bearing D is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 373 -778 B-C 2 -13
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- E 630 -464 E - D 355 -418
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
E-B 510 -75 C-D 195 -121
B - D 544 -452"
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
'"'IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabdcating handlin shi rng, installing and bracing., Ref
erto and follow the latest edition of BCSI (Building
Safety Information by TPI and'SBCA) fog satetpy practices prior to performing these functions Installers shall provide tempora
BCSI. Un ess notes o herwise,top chord shall have properly attached strt�aural sheathing and bottom chord shall have a proppeeryriy
aid ceilingg Locations shown for permanent lateral restraint of webs shall have braclncLinstalled per CSI sections 63, 67 or 610, SCOSTA CORPORATION
le. ,aqpply plates to each face of truss and position as shown above and on the JoinfDetails, unless noted othervvise. (tefer to WOOD STEEL oR TIMBER
60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
of
iIvi 1,orforn
acceptance
any structure
failure to buiilldd the 3670 COMMERCE CENTER DRI1
or 1%. The sUtt2bility S (8s j385 s2a2870
Job Number: 91191 Ply: 1 I SEQN: 26386 / T3 / HIPM
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: B8 Wgt: 63.0 Ibs / ... 05/22/2020
-Loading-Criteria (pso
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category:11
EXP: D
Des Ld: 37.00 D
Des d::
Mean Height:15.00 ft
10.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration:1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/112013)
Top chord 2x4 SP M31 :T2 2x4 SP #2:
Bot chord 2x4 SP M-31
Webs 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at left end of
truss for 486 lbs.
12'9-5/8"
Snow Criteria (Pg,Pt in PSF).
- Defl/CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in too Udell U#
Pf- NA Ce: NA
VERT(LL): -0.030 E 999 360
Lu: NA Cs: NA
VERT(TL): 0.049 E 999 240
Snow Duration: NA
HORZ(LL): -0.016 E - -
HORZ(TL): 0.026 E - -
Code / Misc Criteria
Creep Factor: 2.0
Bldg Code: FBC 2017 RES
Max TC CSI: 0.441
TPI Sid: 2014
Max BC CSI: 0.322
Rep Factors Used: Yes
Max Web CSI: 0.197
FT/RT:20(0)/10(0)
-Mfg Specked Camber.
Plate Type(s):
WAVE
VIEW Ver. 18.02.01A.0205.19
35-5/9' -,
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 486 /- A 1325 /148 /181
D 476 /- A /297 /249 A
Wind reactions based on MWFRS
A Brg Width =- Min Req = -
D Big Width = 3.5 Min Req = 1.5
Bearing D is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 317 -733 B-C 0 -10
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- E 579 -422 E - D 290 -351
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
E-B 505 -109 C-D 161 -98
B - D- 531 -429
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
wire extreme care in fabricatingg handiin , sh! !ng, installing.and bracing., Referto and followthe latest edition of BCSI (Building
Safety. Information b TPI and'SBCA) for sate y practices pnor to performing these functions. Installers shall provide tempora
BCSI. Unless noted oherwise,top chord shall have property attached structural sheathin and bottom chord shall have a pro ryrly
id ceiling. Locations shown forpermanent lateral restraint of webs shall have bracincc��insalled per BCSI sections B3, B7 or10, SCOSTA CORPORATION
e. Apply plates to each face of truss and position as shown above and on the JoiniDetails, unless noted otherwise. Defer to WOOD STEEL OR TIMBER
50A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
a division of
any
failure to build the 3670 COMMERCE CENTER DRI\
or cover e,_ SEBRING,FL33870
1. The s i bllrty (863)385-8242
Job Number: 91191 Ply: SEQN:
/N&A CONSTRUCTION /JURADO/COD /KCD [Wgt: Qty:11 Ibs FROM26415 / T22 / HIPM DRW/ �/22/2020
Truss Label: G1
S12'
ri 66-7/8" 1
8'5"
r 5'9-7/8" - i 2'7-1/8"
- Loading -Criteria (pst)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA
PP Deflection in loc L/defl L/#
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): -0.005 E 999 360
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.010 E 999 240
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): -0.004 E - -
Des Ld: 37.00
EXP: D
Mean Height:ht: 15.00 It
0.006E - -
NCBCLL: 0.00
TCDL: 4.0
Code / Misc Criteria
Code
Creep Factor: 2.0
Soffit: 0.00
BCDL: .0 psf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.417
Load Duration:1.25
MWFRS Parallel Dist: 0 to h/2
TPI Std: 2014
Max BC CSI: 0.210
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Factors Used: No
Max Web CSI: 0.141
Loc. from endwall: NA
FT/RT:20(0)/10(0)
Mfg Speed Camber.
GCpi: 0.18
Plate Type(s):
VIEW Ver. 18.02.01A.0205.19
Wind Duration:1.60
WAVE
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x6 SP #2
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
#1 hip supports 6-4-0 jacks with no webs.
Left side jacks have 6-4-0 setback with 0-M cant
and 2-0-0 overhang. End jacks have 64-0 setback
with 0-0-0 cant and 2-M overhang. Right side jacks
have 0-0-0 setback with 0-0-0 cant and 0-0-0
overhang.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
I
1
AMaximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 410 /- /- /- /228 A
D 688 /- /- /- M83 /-
Wind reactions based on MWFRS
A Brg Width = 3.0 Min Req = 1.5
D Brg Width = 3.5 Min Req = 1.5
Bearings A & D are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 338 -573 B-C 4 -5
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - E 469 -251 E - D 494 -258
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - E 452 -125 C - D 133 -132
B - D 360- -692
""WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
*IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricating handlin ship mg, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
Safety In[ormation by TPI and SBCA) fog safe y practices poor to performing these functions. Installers shall rovide tempos
BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathin and bottom chord ghpall have a pro rryly
id ceiling Locations shown forpemranent lateral restraint of webs shall have bracin insalled per BCSI sections 63, B7 or10, SCOSTA CORPORATION
Apply plates to each face_ of truss and position as shown above and on the JoinfgOetails, unless noted otherwise. Refer to WOOD STE0. OR TIMBER
Of
lips t,ortorn
acceptance
any structure
ROOF bR FLOOR TRUSSES
failure to build the 3670 COMMERCE CENTER DRI\
or cover pa e_ , SEBRING, FL 33870
Ir . The sur brhty (863)385-8242
Job Number: 91191 Ply: 2 SEQN: 26428 / T11 / SPEC
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: G2 Wgt: 162A Ibs / ... 05/22/2020
2 Complete Trusses Required
A 1112X4�_111Y4 _ _ =3�40
=3X8 �
194X1K
ll3J
■
h
I
milli1
111OX'14
8'5"
3f1/2" 8'1-12°
Loading Criteria (psf
Wind Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
TCDL: 7.00
Speed: 159 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: D
Des Ld: 37.00
Mean Height:15.00 it
NCBCLL: 0.00
TCDL: 4.0 psf
Soffit: 0.00
BCDL: 6.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 611/2013)
Top chord 2x4 SP #2
Bot chord 2x6 SP #2 :B2 2x8 SP 2400f-2.0E:
Webs 2x4 SP #2
Lumbervalue set "136" uses design values
approved 1/3012013 by ALSC
Nailnote-
Nail Schedule:0.148"x3.25", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 4.50" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
--(Lumber Dur.Fac. 1.25 / Plate Dur.Fac=1.25)
TC: From 54 plf at 0.00 to 54 pif at 8.42
BC: From 20 pif at 0.00 to 20 pif at 1.29
BC: From 10 plf at 1.29 to 10 pif at 8.42
BC: 1305 lb Conc. Load at 0.47
BC: 1312 lb Conc. Load at 2.47
BC: 1294 lb Conc. Load at 4.47
BC: 1567 lb Conc. Load at 6.47
PLB: 1309 lb Conc. Load at (0.43,12.12)
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC@24"OC
Wind
Right end vertical not exposed to wind pressure.
Snow Criteria (Pg,PP in PSF)
Pg: NA Ct: NA CAT: NP
Pf. NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
WSJ
m4X10
Defl/CSI Criteria
PP Deflection in loc Udell U#
VERT(LL): 0.089 G 999 360
VERT(TL): 0.164 G 616 240
HORZ(LL): 0.031 J - -
HORZ(TL): 0.057 J - -
Creep Factor: 2.0
Max TC CSI: 0.733
Max BC CSI: 0.808
Max Web CSI: 0.645
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
Additional Notes
Truss must be installed as shown with top chord up.
"WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
-IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Of
ivi i,ortorn
acceptance
any structure
�straim of wens snan nave Dracing mstaiiea per ts,
as shown above and on the JoinfDetails, unless
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
K 4653 /- A /- /2034 /69
E 2686 /- A /406 /1169 A
Wind reactions based on MWFRS
K Brg Width = 3.0 Min Req = 2.7
E Brg Width = 3.5 Min Req = 1.5
Bearings K & E are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 40 -96 C - D 478 -1147
B-C 39 -95
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
K-1 96 -75 H-F 57 -101
J-H 57 -102 F-E 3 -2
I- G 296 -141
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
A - K
130 -296
G - F
1450 -625
J-1
2140 -837
C-F
219 -1
B - G
362 -101
F - D
1561 -650
G - H
726 -1571
D - E
479 -1090
G-C
470 -1119
n of BCSI (Building
provide temporary
call have a properly
ns B3 B7( or Br to
iervvROO
SCOSTA CORPORATION
FbRTFLOOR TRUSSES
failure to build the
3670 COMMERCE CENTER DRIVE
ig or cover page _
SEBRING, FL 33870
in. The suttabihty
(863)335-8242
Job Number. 91191 Ply: 1 SEQN: 26409 / T48 / MONO ' I
/NBA CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: H1 I Wgt: 35.7lbs .. / ... 05/22/2020
=2M(j
L
SEAT PLATE REQ.
7'
Loading. Criteria (psti
Wind Criteria
Snow Criteria (Pg,Pf in PsF)
DefUCSI Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udell U#
TCDL: 7.00
Speed: 159 mph
Pf: NA Ce: NA
VERT(LL): 0.055 D 999 360
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(fL): 0.099 D 833 240
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.021 D - -
Des Ld: 37.00
EXP: D
HORZ 0.038 D
rn)'
Code / Misc Criteria
NCBCLL: 10.00
Mean Height:15.OD ft
TCDL: 4.0 psf
Creep Factor: 2.0
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.436
Load Duration:1.25
MWFRS Parallel Dist: 0 to h/2
TPI Sid: 2014
Max BC CSI: 0.853
Spacing: 24.0 "
C&C Dist a: 3.00 it
Rep Factors Used: Varies by
IlmdlrYMkb CSI: 0.155
Loc. from endwall: not in 9.00 it
. Ff/RT:20(0)/10(0)
Mfg Specked Camber.
GCpi: 0.18
Plate Type(s):
VIEW Ver. 18.02.01A.0205.19
Wind Duration:1.60
WAVE
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP M31
Bot chord 2x6 SP M-14
Webs 2x4 SP #2
Lumber value set "139" uses design values
approved 1/30/2013 by ALSC
Special Loads
---(Lumber Dur.Fac. 1.25 / Plate Dur.Fac. 1.25)
TC: From 55 plf at 0.00 to 55 plf at 7.00
BC: From 10 pit at 0.00 to 10 plf at 7.00
BC: 486 Ib Conc. Load at 1.06, 3.06, 5.06
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Wind
Right end vertical not exposed to wind pressure.
Additional Notes
Provide hanger or special connection at right end of
truss for 843 lbs.
w
77
l
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 1071 A /- A /449 /-
D 843 A P A M88 /-
Wind reactions based on MWFRS
E Big Width = 8.0 Min Req = 1.5
D Big Width = - Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chards Tens. Comp.
A-B 342 -521 B-C 54 -82
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-D 541 -318
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - D 352 -591 C - D' 46 - 7
-WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
*"IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
uire extreme care in fabricating hand in ship ing, installing,and bracing. Referto and followthe latest edition of BCSI (Building
Safety Information b TPI and SBCA) for safe y practices poor to performing these functions. Installers shall pmvide tempora
BCS1. Unless noted ohetwise,top chord shall have properly attached structural sheathin and bottom chord shall have a pro ryrly
id ceding Locations shown forpermanent lateral restraint of webs shall have bracincLinsalled per BCSI sections B3, 67 or �10, SCOSTA CORPORATION
e. AP
ly plates to each face, of truss and position as shown above and on the JoiniDetails, unless noted otherwise. Refer to wood sTEEL OR TIMBER
60A Z for standard plate positions. ROOF bR FLOOR TRUSSES
vision of ITW Buildingg �Components Group Inc. ,shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRn
Ifomtance with ANSI/TPI 1, or for handling shi��in�, installation and bracing of trusses. A seal on this �drawmq or cover page sEBRING, FL 33870
drawing, indicates acceptance of profess na ,engineering__responslbilrty solelyfor the design show The s i bility (a63)385 6242
Job Number. 91191 Ply: 2 SEON: 26416 / T54 / HIPM
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss Label: 11 1 Wgt: 36.4 Ibs .. / ... 05/22/2020
2 Complete Trusses Required
I _ 3' 19-1 / '
_
12
5 p
2X4(A1) A
3.15 16"
F
3'9-1 /8"
=4X5 B T2 E2X4
.4
fi
Loading. Criteria (pst) Wind Criteria . Snow Criteria (Pg,PF in PSF) Defl/CSI Criteria
♦Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in too Udefl U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 159 mph Pf; NA Go: NA VERT(LL): 0.017 E 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT 0.032 E 999 240
rn):
F 887 Pi- /- 266 /-
Risk Category: 11
BCOL: 10.00 e9 ry Snow Duration: NA HORZ(LL): 0.007 E - -
D 858 P P P P259 P
EXP: D HORZ 0.013 E - -
(TI-)� Des Ld: 37.00
Wind reactions based on MWFRS
NCBCLL: 0.00 Mean Height:15.00 it Code / Misc Criteria Creep Factor: 2.0
F Brg Width = 3.5 Min Req = 1.5
TCDL: 4.0 psf
Soffit: 0.00 BCDL: 6.0 sf Bldg Code: FBC 2017 RES Max TC CSI: 0.277
D Brg Width = - Min Req = -
P
Load Duration:1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.704
Bearing F is a rigid surface.
Spacing: 24.0 " C&C Dist a: 3.00 it Rep Factors Used: No Max Web CSI: 0.041
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Mfg Specified Camber.
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18 Plate Type(s):
A - B 15 -24 B - C 9 -29
Wind Duration:1.60 WAVE VIEW Ver. 18.02.01A.0205.19
Lumber
Maximum Bot Chord Forces Per Ply (Ibs)
Value Set: 13B (Effective 6/112013)
Chords Tens.Comp. Chords Tens. Comp.
Top chord 2x4 SP #2
A- E 32 -13 E - D 29 -8
Bot chord 2x6 SP #2
Webs 2x4 SP #2
Maximum Web Forces Per Ply (Ibs)
Lumber value set "136" uses design values
Webs Tens.Comp. Webs Tens. Comp.
approved 1/30/2013 by ALSC
B-E 40 -21 C-D 24 -78
Nailnote-
Nail Schedule:0.148'X3.25", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @ 4.75" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
--(Lumber Dur.Fac. 1.25 / Plate Dur.Fac. 1.25)
TC: From 28 plf at 0.00 to 28 plf at 3.00
TC: From 55 pif at 3.00 to 55 pif at 3.76
BC: From 10' plf at 0.00 to 10' plf at 176-
TC: 72 lb Conc. Load at 3.03
BC: 1471 lb Conc. Load at 1.82
BC: 40 lb Conc. Load at 3.03
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
Provide hanger or special connection at right end of
truss for 858 lbs.
*"WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
-IMPORTANT`* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin ,shi rng, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information by TPI fabricating,
for sate y practices prior to performing t(rese functions. Installers shall provide temporary
bracing BCS� herwise,top have and bottom chord shall have a rly
er ,Unless notes o chord shall property attached structural sheathrnp
attache�ri id ceifmg Locations shown forpermanent lateral restraint of webs shall have bracincLmslalled BCSI sections
pro
63, 67 or10, SCOSTA CORPORATION
per
as applica��e. �ppi plates to each face of truss and posdion as shown above and on the Joint Details, unless noted otherwise.
drawings 60A fo standard plate poSltlOnS.
Defer to wooD sTEEL oR TInABER
ROOF bR FLOOR TRUSSES
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing any failure
truss in ANSI PI 1, installation trusses A on this rawin or
bracing
for handling,
to build the 3670 COMMERCE CENTER DRIVE
cover
conformance with or shi In , and of seal page _ SEBRING, FL 33870
list!n this drawing Indicates acceptance of Aress{'�'na� englneerinqq res onbility soleiyfor the desip show�i. The suitability (863)385-8242
and $se of this drawing for any structure is the responsibility of the 6uilding Desigrfer per ANSI/TP11 Sec.2.
Job Number: 91191 Ply: 1 1 SEQN: 26401 / T20 / VAL
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 2 FROM: DRW.
Truss Label: V5 I Wgt:14.0 Ibs .. / ... 05/22/2020
Loading. Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
-4+ll4"
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category: II
EXP: D
Mean Height:15.00 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: h/2 to It
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Webs 2x4 SP #2
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ ZV OC
Additional Notes
See applicable standard valley or piggyback details
for more requirements.
i �-3/8" ! —3'3-1/16' �{
12 R
CO
&11-3/9' -
i 37-7/8" 4 T
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT, W
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
1113X5
Defl/CSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): -0.003 C - -
HORZ(TL): 0.005 C - -
Creep Factor: 2.0
Max TC CSI: 0.214
Max BC CSI: 0.195
Max Web CSI: 0.062
Mfg Specked Camber.
VIEW Ver. 18.02.01A.0205.19
♦Maximum Reactions (Ibs), or*=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
D' 75 /- /- /47 /32 /21
Wind reactions based on MWFRS
D Big Width = 47.4 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 23 -67
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 146 -18
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
B-C 193 -88
'"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"*IMPORTANT'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricatingp handling, she Ing, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
Corrlportent Safety. Information by TPI and'SBCA) for satety practices pnor to performing these functions. Installers shall provide temporarx
brace g per BCSI., Unless note o helwise,top chord shall have property attached structural sheathing and bottom chord shall have a pro r
attac�ied rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin, nsdailed per BCSI sections B3, B7 or g10, SCOSTA CORPORATION
as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Defer to WOOD STEEL oR TIMBER
drawings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Alpine. a division of ITW Buildina Components Group Inc. shall not be responsible for anv deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIB
g or cover ppage, , SEBRING, FL 33870
m. The SUlt�bllrty (863)385M42
rpi 1, or torn
acceptance
any sructure
Job Number. 91191 Ply:1 SEQN: 26402 / T12 / VAL
/N&A CONSTRUCTION /JURADO/COD /KCD Qty: 1 FROM: DRW:
Truss label: V6 I Wot: 11.2 Ibs ... / ... 05/22/2020
Loading. Criteria (pst)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration:1.25
Spacing: 24.0 "
Lumber
-!f+ 1,3-1/16" + 1'3-1/16-
12
5 F,—,-
3M(D1) T1 8=3X4 T1X4(D1)
C
0
D
B1
Wind Criteria
Wind Std: ASCE 7-10
Speed: 159 mph
Enclosure: Closed
Risk Category:11
EXP: D
Mean Height:15.82 ft
TCDL: 4.0 psf
BCDL: 6.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 It
GCpi: 0.18
Wind Duration:1.60
Value Set: 13B (Effective 611/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 byALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ 24" OC
Additional Notes
See applicable standard valley or piggyback details
for more requirements.
�- 310-13/16" —I
Snow Criteria (Pg,Pr in PSF)
Pg: NA Ct: NA CAT: W
Pf: NA Ce: NA
Lu: NA Cs: NA .
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 2017 RES
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc Udell U#
VERT(LL): 0.004 999 360
VERT(TL): 0.008 999 240
HORZ(LL): -0.001 - -
HORZ(TL): 0.003 -
Creep Factor: 2.0
Max TC CSI: 0.072
Max BC CSI: 0.101
Max Web CSI: 0.000
Mfg Specified Camber.
VIEW Ver. 18.02.01A.0205.19
♦Maximum Reactions (Ibs), or "=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
D` 75 /- !- 127 /23 /5
Wind reactions based on MWFRS
D Brg Width = 46.8 Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 263 -195 B - C 263 -195
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A - C 197 -222
'"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
wire extreme care in fabricatingg handlingg shi mg, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
Safety Information by TPI and'SBCA) fog safety practices prior to performing these functions. Installers shall provide temporary
BCSI. Unless noted oiherwise,top chord shall have properly attached structural shgathinqq and bottom chord shall have a properly
iid ceiling. Locations shown forpermanent lateral restraint of webs shall have bracin ns�ailed per BCSI sections B3, B7 or B10, SCOSTA CORPORATION
e. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Defer to WOOD STE0. OR TIMBER
60A Z for standard plate positions. ROOF bR FLOOR TRUSSES
Of
l PI 1, or for h
acceptance
any sructure
failure to build the 3670 COMMERCE CENTER DRI1
g or cover pa�qe, _ SEBRING, FL 33870
Fri. The Spltabrllty (863)385-8242
Job Number. 91191
Ply: 1
SEQN: 26403 / T17 / VAL
INBA CONSTRUCTION /JURADO/COD /KCD
Qty: 1
FROM:
DRW:
Truss Label: V7
Wgt: 25.2 Ibs
/ ... 05/22/2020
/ + 3'3-1 /15' 8�/S"
—3'3-1/15'�--
12
5 B=4X4
T1
T1
3X4(D1 _3X4(DC1)
A W1
1
E
B1 13 IIf2X4
Tl 0-13/16"
�-- 3'9-5/8" 3f /T 3'9-5/9-
Loading Criteria (pso
Wind Criteria
Snow Criteria (Pg,Pf in PSF) .
Defl/CSI Criteria
♦Maximum Reactions (Ibs), or'=PLF
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT. NA
PP Deflection in too Udefl U#
Gravity Non -Gravity
TCDL: 7.00
Speed: 159 mph
Pf. NA Ce: NA
VERT(LL): 0.008 D 999 360
Loc R+ / R- / Rh / Rw / U / RL
E' 75 /- /- /32 /33 !7
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(TL): 0.014 D 999 240
BCDL: 10.00
Risk Category: it
Snow Duration: NA
HORZ(LL): 0.003 D - -
Wind reactions based on MWFRS
Des Ld: 37.00
EXP: D
HORZ(TL): 0.005 D - -
E B Width = 94.8 Min Req
gA
Code / Misc Criteria
Code
NCBCLL: 10.00
Mean Height:15.41 It
TCDL: 4.0 psf
Creep Factor: 2.0
is a rigid surface.
Soffit: 0.00
BCDL: 6.0 psf
Bldg Code: FBC 2017 RES
Max TC CSI: 0.193
Maximum Top Chord Forces Per Ply (Ibs)
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
TPI Sid: 2014
Max BC CSI: 0.171
Chords Tens.Comp. Chords Tens. Comp.
A - B 199 -213 B - C 199 -214
Spacing: 24.0 "
C&C Dist a: 3.00 It
Rep Factors Used: Yes
Max Web CSI: 0.079
Loc. from endwall: not in 9.00 ft
FT/RT:20(0)/10(0)
Mfg Specified Camber.
GCpi: 0.18
Plate Type(s):
Maximum Bot Chord Forces Per Ply (Ibs)
Wind Duration:1.60
WAVE
VIEW Ver: 18.02.01A.0205.19
Chords Tens.Comp. Chords Tens. Comp.
Lumber A-D 285 -156 D-C 285 -156
Value Set: 13B (Effective 6/112013)
Top chord 2x4 SP #2 Maximum Web Forces Per Ply (Ibs)
Bot chord 2x4 SP #2 Webs Tens.Comp.
Webs 2x4 SP #2
Lumber value set " 13B" uses design values B - D 447 -286
approved 1/30/2013 by ALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid ceiling provide lateral bracing to brace
BC @ ZV OC
Additional Notes
See applicable standard valley or piggyback details
for more requirements.
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
-IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handling shi pmg, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
Componenf Safety. Information b TPI and SECA) toy sateiy practices pnor io performing these functions. Installers shall provide tempora ry0
bracing BCSI Unless have bottom have
er noted olherwise,top chord shall properly attached structural sheathingand chord shall a pro
attache �ri id ceifing. Locations shown forpermanent lateral restraint of webs shall have bracinc(L�mstalled per BCSI sections B3, B7 or 110, SCOSTA CORPORATION
Refer
as applicable. Apply plates to each face oftrussand position as shown above and on the Joinmetails, unless noted otherwise. to WOOD STEEL OR TIMBER
dravRings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing arty failure to build the 3670 COMMERCE CENTER DRIVE
truss in
conformance with ANSI�I 1, or for handlin shi in , installation and bracin of tmsses.A seal on this tlrawinqq or cover Dpaagqe SEBRING, FL 33870
listing this drawin indicates acceptance of rdgfess{'d'na� engineerin�q responibil' solely for the desigpn showTi. The sUitftbility (863)385 8242
and Fise of this �taW ng for any structure is the responsibil Qof the guifdi g Designer per ANSIITPf is €c.Z.
For more information see this ob's general notes page and these web sites ALPINE: • TPI: • SBCA: jCC:
Job Number. 91191 Ply: 1 SEQN: 26404 / T19 / VAL
/N&A CONSTRUCTION /JURADO/COD /KCD City: 4 FROM: DRW.
Truss Label: V8 Wgt: 5.6 Ibs / ... 05/22/2020
Loading Criteria (psi) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-10
TCDL: 7.00 Speed: 159 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
Des Ld: 37.00 EXP: D
Mean Height:15.00 ft
NCBCLL: 10.00 TCDL: 4.0 psf
Soffit: 0.00 BCDL: 6.0 psf
Load Duration:1.25 MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 " C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 It
GCpi: 0.18
Wind Duration:1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2
Bot chord 2x4 SP #2
Lumber value set "13B" uses design values
approved 1/30/2013 byALSC
Loading
Bottom chord checked for 10.00 psf non -concurrent
live load.
Purlins
In lieu of rigid Gelling provide lateral bracing to brace
BC @ ZV OC
Additional Notes
See applicable standard valley or piggyback details
for more requirements.
n
1'3-1 /16" --�
12
5 p
T
0
1' 11-3/8" --{
Snow Criteria (Pg,Pf in PSF)
Deft/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
Pg: NA Ct: NA CAT. NA
PP Deflection in loc Udell U#
Gravity Non -Gravity
Pf: NA Ce: NA
VERT(LL): 0.003 B 999 360
Loc R+ / R- / Rh / Rw / U / RL
Lu: NA Cs: NA
VERT(TL): 0.006 B 999 240
D* 75 /- /- /41 /21 /16
Snow Duration: NA
HORZ(LL): -0.001 B - -
Wind reactions based on MWFRS
HORZ(TL): 0.002 B - -
D Brg Width = 23.4 Min Req = -
Code I Misc Criteria
Creep Factor: 2.0
Bearing A is a rigid surface.
Bldg Code: FBC 2017 RES
Max TC CSI: 0:038
Maximum Top Chord Forces Per Ply (Ibs)
TPI Std: 2014
Max BC CSI: 0.086
Chords Tens.Comp.
Rep Factors Used: Yes
Max Web CSI: 0.000
A - B 0 -13
FT/RT:20(0)/l0(0)
Mfg Specified Camber -
Plate Type(s):
Maximum Bot Chord Forces Per Ply (Ibs)
WAVE
VIEW Ver. 18.02.01A.0205.19
Chords Tens.Comp.
A-C 62 -9
*"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
-IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
�btraint bf webs shall have bracinccC�installed per B,
as shown above and on the Joinf-Details. unless
Alpine, a division of ITW Buildin Cc
truss in conformance with ANSI�I
Ilstin this drawin indicates acc
and �se of this 9tawing for any
For more information see thislob's general nr
n of BCSI (Building
provide temporary
hall have a prorty
B3, B7 B10,
ins or
terwise. Defer to
SCOSTA CORPORATION
WOOD STEEL OR TIMBER
ROOF bR FLOOR TRUSSES
failure to build the
3670 COMMERCE CENTER DRIVE
ig or cover e
SEBRING, FL 33870
in. The s i bility
(863)385-8242