Loading...
HomeMy WebLinkAboutOC SHINGLE DURATION VER 2020Business Professional Regulation W IS ft,,, Tea in 1 user Reaxrau n Im T.W. dbbda reorl go Prus Aoproval Prod Puallc uee, 122® Supnrz surmanse I apu a ncts Pvbuouore conl.n m ',. ons sne Map onl¢ ses.ro Fro".P "a a NPnutbn Mall FL 6 FLR16 Application Type Revision Code Version 2020 Application Status Pending FBC Approval Comments Archived Product Manufacturer Owens Corning Address/Phone/Emall One Owens Corning Parkway Toledo, OH 43659 (740) 4047829 greg.keeler@owenscaming.mm Authorized Signature Greg Keeler greg. Keeler@owenscarning.mm Technical Representative Mel Sanaant Add,ss/Phone/Email i Owens Coming PKWY Toledo, OH 43659 (419) 376-8360 mel.sancant@owenscomig.mm Quality Msurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Processional Engineer Evaluation Report - HardcopY Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminan Evaluation Report Florida License PE-59166 Quality Assurance Entity PRJ Construction Materials Technologies, LLC Quality Assurance Contrec Expiration Date 01/O1/2099 Validated By John W. KnetaAch, PE Validation Checklist - HardcoPY Received Certificate of Independence F 1➢6]4 001 R16 2010 01 Coi NI KIN N aL Referenced Standard and Year (of Standard) Standard Year A D1970 2015 ASTM D3161 2016 ASTM 03462 2010 ASTM D7158 2019 Equivalence of Product Standards Certified By Sections from the Code Prod.d Approval Method Method 1 Option D Data Submitted 12/11/2020 Date Validated 12/17/2020 Data Pending PIC Approval 12/26/2020 Summary a Products r FL s bludelr Number or Name ttescriptlon 30674.1 Owens Coming AsphaR Roofing 3-tab, 4-tab, laminated, starter and hip A ridge shingles Shingles and Starters Limits of use Approved for use In HPI No t Installation Instructions m ul Approved for use outside Will Yes FIL1Install Rlfi 0 11 11 FINA 0. OC PF ALT SHINGLES FL10674-R16pol Design DResistsnt N/A esign Pressure: N/A Verified By: Robert d. M. Nieminen PE - 59166 Other: Refer [o ER, Section S. Created by Independent Third Party: Yes Evaluation Reports FL106]4 Rlb AE 20 0 11 FINA R 0 A PH T SHINGES FL10674-Rl6pol Creabed by Independent Third Party: Yes O Nwt 6aNan,.,:: ZiMil as' eb Williams, 1113's Ppone'-50187-1.1 The small of Honda is an WEO employee GwnF�a grva,dominant ;; -ep ry�en.�nt. ofad'd statement Undid, mtHondda aw, emall adamod. are pYn; rtwde. If you do nM want your e-nad adores¢ mleaand In MsWw W a publicrecpEs rtpues[, do not aerd electronic am an ¢moll address wM[b [ao be made avdu. m W Me public 2adetemiu nle If ,in a If you do no you art a Ilttnaee Product AePrml l[mph ®®®R® Credt Card Sate 21 ENGINEER EVALUATE 9N RFPr NEMO l etc. Certificate ofAuthonzation #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 TEST CONSULT Owens Corning Evaluation Report 037940.02.12-1131 One Owens Corning Parkway FL30674-1136 Toledo, ON 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 11: 12/21/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the Th Edition (2020) Florida Building Code sections noted herein. DESCRiPRON: Owens LABEUNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPUANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: ao�ov;^, , — i'N �9 sti :•,• meisonngeualaoseanM ngwasaunriad bracken Robert J.M. Merriman, P.E.-<."..' ••,•�9^``�:�i:,,£' Nieminen,Peon12/11/2020. mNdoesr eamasan Florida Registration No. 59166, Florida DCA ANE1983 aecwnloalNslened aowmant. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is notowned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the Product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02028 NEW ETC, LLC ROOFING SYSTEMS EVALUATION: OONEMOJetc. r• Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 71° Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Pr<�wn Property StanOrd Year 1507.2.4, R905.2.3 Physical Pmperties ASTM D1970 2015 1507.2.5, R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 3. REFERENCES: Lnft Examination Reference Date Owens Coming Declaration Equivalency Declaration 08/06/2019 PRI (TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC(CER9626) Physicals& Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC(CER9626) Physicals& Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LUC(TST9628) Wind Resistance IICA34308 02/19/2012 UL LLC(TST9628) Physicals& Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TS19628) Physical Properties Classification letter 10/02/2015 PRI(QUA9110) qualityContml Service Confirmation 04/OS/2020 PRI(QUA9330) quality Control Florida BCIS Current DESCRIPTION:4. PRODUCT TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material DescriptionStandard Starter Stin Shingle H-TX, OR Accessory Starter Starter Strip Plus MN, OR ASTM D3462 starter strips for asphalt roofshingles SRS TopShleld Starter MN, OR Strips Starter Shingle Roll NH ASTM D1970 minemisudaced, fiberglass -reinforce self-adheringsBS modmM bltumenrtarter Supreme' GA, CA, CO, I -TX, NI, OH, TN, OR, It A5TM D3462 fiberglass reinforced 3-tab asphalt roof shingles Berkshire' MN ASTM D3462 fiberglass reinforced, 4-tab asphalt roofshin les Duration'Premium CA, OR Asphalt Shingles g Duration' Premium COOL CA ASTM 03462 fiberglass reinforced, laminated asphalt roof shingles TruDeftnitlon' Duration' IN, CM CO,1-TX, FL, Nl, OH, MN, OR, GA, IL, TN TruDefnition' Duration' Designer Color Collectlon Oakridge GA, IN, CA, CO, H-TX,-TX, FL, NI OH, TN TruDefinition'Oakridge' H-TX,I-TX WeatherGuard' HP TN NEMO ETc, LL[ Evaluation Report 037540.02.11-1111 Qmpm .M.hnntadoam,ss 7a'EDITION (2020)FBC NON-HVHZ EVALUATION FL306]4-RS6 Owens Carving Asphalt Roof Shingles Revision 11: 12/11/ZO20 Page 2 of 10 ONFruiniptr TABLE 1: ASPHALTSHINGIE COMPONENTS Type Product Plants) Material DescriptionStandard Berkshire HIPand Ridge Shingles with Sealant MN Hip and DuraRidgee Hip and Ridge Ridge Shingles with Sealant MN ASTM D3462 fiberglass reinforced, hip and ridge Shingles asphalt roof shingles ProEdgee GA, CA OH, OR WeatherGuard' HP Hip and Rid e5hingles TN 5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE ZA: WINO CLA59IFicA71oNs, AsP TSHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Supreme ASTM D3361(F) &ASTM D7158(11) Berkshire' Duration Premium Duration' Premium COOL TruDefinition Duration TruDefnition' Duration' Designer Color Collection Oakndgea TruDeOnRion Oakrldgee Weathertivard* HP 5.5.1 Classification by ASTM D715g: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO mq LLC Evaluation Report 037M.02.12•g11 [ert�iWrtoJAUMONxmion Y32A56 7' EDITION (2020) FBC NON-WHZ EVALUATION FL106741136 Owens Coming Asphalt go& Shingles R¢Wsbn 12:12/11/2020 Page 3 of 10 ONEMOJetc. TAgur 28: WIND CluSSDICATIONS, STARTER STRIPSAND HIP & RIWs Type Product FBC Table 1507.2.7.1 or R905.2.6.1 Starterstdps Starter Strip Shingle ASTM D3161, Class Starter Strip Plus SRS TopShield Starter HIP &Ridge Shingles Berkshire' Hip and Ridge Shingles with Sealant ASTM D3161, Class F DuraRidge° Hip and Ridge Shingles wRh Sealant PmEdge° WeatherGuard' HP Hip and Ridge Shingles 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Pagel of this Evaluation Report. 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use In reroof (tear -oft) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 Attetsoarr STARTED: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published Instructions, using minimum five (5) nails per strip. Figure 1: Minimum Nallm& Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEMO ETC, L C Evulanti Report 0379W.0212•N31 Cerfd ate ofAUMoNmrion p33455 7- EDITION (2020) I'M NON-HVHZ EVALUATION F406741136 Owens Carning Asphaft Roof Shingles Reeisron 11: 22/12/2020 Page 4 Pf 10 6.2.2 fkimojetc. Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Figure 3: Starter Shingle Roll 6.3 ASPHA TSHINp1FS: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published Instructions, using minimum four (4) nails per shingle In accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five (5) nails per shingle. ➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Nasn.l Ma .... d.. A —pare wind A.. High wind de.v.nea y A/aa P/r/ vienrPf aermeix A.. ean,. = + ++ m E.poyun E�p..icidn Figure 4: Minimum Nailing, Supreme (Standard Size) N. .I M.merd or Arw p.r. Wind Ar... High wind Menmey Ares pen.iwrtee nnena,.x Aa.. viem.r hnn. IAi * f+• IB 4• ,• Le' Ex"Sure Eapomcmn Figure 5: Minimum Nailing, Supreme (Metric Sim) NEMO ETC, UC Evaluation Report 037M.M.12-KII eenglmte ufA. d aden #3205 7'a EDITION (2020) FBC NON-HVHz EVALUAIION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 5 of 10 6.3.1.2 Berkshire.. SeabM Arip Li III• MSaNIO 0N" 0Yf 9h' 0YY 1 Figure 6: 5-Nall Pattern, Berkshire ONEMOjeft. Srlen[stlip 1 /Le lvah iniatlor Figure ): 6-Nail Pattern, Berkshire sea6mnnp Lzmatgyl4M a s�rn p 1" l re{" 1 ASOXaX roaTgsncenr Cemmlo dahrMtle eVeM1a Figure 8: Mansard or Steep Slope Pattem,Berkshire NEMO ETC, LLC Evaluation Report 032940.02.12-101 Ceniift. ajAufFatlm(p002455 PE09ION 12020) FBC NON-HVHZ EVALUATION FLW674-1116 Owens Corning Asphalt goof Shingles Revision 11: 22/11120M Page 6 of 10 ONEMOletc. 6.3.1.3 Durationa Premium, TmDefinitione Duration, Duration* Premium COOL & TruDefinition' Duration' Designer Color Collection: Figure 9: Standard 0-N211 Pattern, Duration 6-Nail Fastening Pattern surewaMIDraanNpan WEq r fiat 1Ypcal Ir I. F1 F� [L 8118" Sy8 Figure 10: 4Nail Pattern, Duration Na Greater Than 21:12 ...xae®lummnp area.mh r Nen. ryq[m tg^ Fgure 11: Mansard or Steep Slope Pattern, Duration NEMD Err, LLC EvaluaUOn Repun 037M.OZ.1Z•R31 redlfWWojAuthozvIYna3W5 T'vEDITION (2020)FaC NON-NVNZ EVALUATION FI10167"16 Causes Corning Asphalt Reol Shingles Revision 11: 12/11/20M Page 7 P110 6.3.1.4 TruDeFlnition' Oakridgen Oakride W: 4 Nil Paltan Es4uwn,t.4daws T ISM &pow wtq 65N 6E Eyacddndm66/Ryu:g. Cb✓ Expasltiott&66R{ Figure 12: Standard 4-Nail Pattern, Oakridge 6.3.1.5 WeatherGuarde HP: u^ ONEMOletc. 6 Nall Pytum Epuwnays6Naws 1'P T 5�CxpauN Cb� fi6N Fkpoww� FkpaMG'ds66/B➢WB. Ex{oadvn G66/BWIp Figure 13:6-Nail Pattern, Oakrdge swensa w...we . r-NAA Taw! rmure av: mansara or meep-mope Pattern, Oakndge 6 Nei Pattern EsWesre con 6 dakos NO 6 W from Late. of dingle 6518'EFpowre 6Fas[emrs Om a 6 tl8oW. deb Eaposign de 5 6g fig. 6 sujetAi4rss Pate iNaia k iFja t• rPi isµ NR �pts EANNaLAeers 6e mN &,kg Was Chase, Fee W in seemMtotde t�eo5o de $fee de 1191l Figure 15: 6-Nail Pattern, WeatherGuard HP figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HIP NEMO ETC, LW EnaluatlOn Report 039940.02.12-1131 CeniAmt,0fA,ehwaaWn R324S5 Y"EDITION (2020)FK NON-HVHI EVALUATION FL30674-Ri6 Owens Corniry Asphalt Roof Shingles Rentalon 11: 12/11/2020 Page 8 of 10 ONEMOletc. 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. D Berkshire' Hip and Ridge Shingles with Sealant and DuraRidgee Hip and Ridge Shingles with Sealant require minimum two (2) nails per shingle. ➢ WeatherGuard' HP Hip and Ridge Shingles and Prolidgee require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire- Hioand Ridge with Sealant and D rallid es Hip and Ridge Shingles with Sealant Prevailing Wind Direction Direction del vlenW predominance 6.4.1.2 WeatherGuard-HP Hip and Ridge Shi gles- Fig. A vrawp name �—olr«mn° W Ib I I i A I I I �pauw Figure 19: Isometric View, WeatherGuard Fig. B ToPviaw Vima superior 1 1" 2W NYI as p awYYfprnYlg (ANNYi' I I I. AIL I Sim I� I �. 12' Figure 18: Plan View, Berkshire and Durallidge Fig. C Hip & Ridge Shingle Fastening TopVW We WIY r. T R" r r 1" 1 6" sapow. ie +r —al Figure 20: Plan View, Weathercivard HP Hip and Ridge NEMO rTS LLE EValUatlen Report 037940.02d2-R31 Gsrsf.o JAodprkarbn Y32455 TTM EDITION (2020) Pat NON-NVK EVAWATION FE30674-1136 Owens corning Asphalt Roof shingles Revision 11: IZIIVZ020 Page 9 of 10 6.4.1.3 ProEdge- NNEMO I etc. Prevailing Wind Dirasclon Seale"gtnp fi'Eapesure Fetlen TL- Feewl ne en wlih lInK cement Figure 21: Isometric View, ProEdge SWedeld •—it'—= Fr 1" PRlben IY &alanl 7A' B'EWspNip Figure M: Plan View, ProEdge 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. Construction Materials Technologies, LLC- - END OFEVALUATION REPORT - MEMO ETC, LLC EvaluatiDn Repon 0373a0A2.12-R31 RMprurcofpuMwIIa(wn p33055 7- EDITION 120201 Fat NON-NVNI EVPLUATION FL10E)MRlb Owens Corning Asphah Roof shingles Revision 11: 12/11/20M Page 10 of 10