HomeMy WebLinkAboutOC SHINGLE DURATION VER 2020Business Professional Regulation
W IS ft,,, Tea in 1 user Reaxrau n Im T.W.
dbbda reorl go Prus Aoproval
Prod Puallc uee,
122®
Supnrz surmanse I apu a ncts Pvbuouore conl.n m ',. ons sne Map onl¢ ses.ro
Fro".P
"a a NPnutbn Mall
FL 6
FLR16
Application Type
Revision
Code Version
2020
Application Status
Pending FBC Approval
Comments
Archived
Product Manufacturer
Owens Corning
Address/Phone/Emall
One Owens Corning Parkway
Toledo, OH 43659
(740) 4047829
greg.keeler@owenscaming.mm
Authorized Signature
Greg Keeler
greg. Keeler@owenscarning.mm
Technical Representative
Mel Sanaant
Add,ss/Phone/Email
i Owens Coming PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancant@owenscomig.mm
Quality Msurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Asphalt Shingles
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Processional Engineer
Evaluation Report - HardcopY Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminan
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
PRJ Construction Materials Technologies, LLC
Quality Assurance Contrec Expiration Date
01/O1/2099
Validated By
John W. KnetaAch, PE
Validation Checklist - HardcoPY Received
Certificate of Independence
F 1➢6]4 001
R16 2010 01 Coi NI KIN N aL
Referenced Standard and Year (of Standard)
Standard
Year
A D1970
2015
ASTM D3161
2016
ASTM 03462
2010
ASTM D7158
2019
Equivalence of Product Standards
Certified By
Sections from the Code
Prod.d Approval Method Method 1 Option D
Data Submitted 12/11/2020
Date Validated 12/17/2020
Data Pending PIC Approval 12/26/2020
Summary a Products
r
FL s
bludelr Number or Name
ttescriptlon
30674.1
Owens Coming AsphaR Roofing
3-tab, 4-tab, laminated, starter and hip A ridge shingles
Shingles and Starters
Limits of use
Approved for use In HPI No
t
Installation Instructions
m ul
Approved for use outside Will Yes
FIL1Install
Rlfi 0 11 11 FINA 0. OC PF ALT
SHINGLES FL10674-R16pol
Design DResistsnt N/A
esign Pressure: N/A
Verified By: Robert d. M. Nieminen PE - 59166
Other: Refer [o ER, Section S.
Created by Independent Third Party: Yes
Evaluation Reports
FL106]4 Rlb AE 20 0 11 FINA R 0 A PH T
SHINGES FL10674-Rl6pol
Creabed by Independent Third Party: Yes
O Nwt
6aNan,.,:: ZiMil as' eb Williams, 1113's Ppone'-50187-1.1
The small of Honda is an WEO employee GwnF�a grva,dominant ;; -ep ry�en.�nt. ofad'd statement
Undid, mtHondda aw, emall adamod. are pYn; rtwde. If you do nM want your e-nad adores¢ mleaand In MsWw W a publicrecpEs rtpues[, do not aerd electronic
am an ¢moll address wM[b [ao be made avdu. m W Me public 2adetemiu nle If ,in a If you do no
you art a Ilttnaee
Product AePrml l[mph
®®®R®
Credt Card
Sate
21
ENGINEER EVALUATE
9N RFPr
NEMO l etc.
Certificate ofAuthonzation #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
TEST CONSULT
Owens Corning Evaluation Report 037940.02.12-1131
One Owens Corning Parkway FL30674-1136
Toledo, ON 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 11: 12/21/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the Th Edition (2020) Florida Building Code sections noted herein.
DESCRiPRON: Owens
LABEUNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPUANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by: ao�ov;^, , —
i'N
�9 sti :•,• meisonngeualaoseanM ngwasaunriad bracken Robert J.M. Merriman, P.E.-<."..'
••,•�9^``�:�i:,,£' Nieminen,Peon12/11/2020. mNdoesr eamasan
Florida Registration No. 59166, Florida DCA ANE1983 aecwnloalNslened aowmant.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is notowned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
Product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02028 NEW ETC, LLC
ROOFING SYSTEMS EVALUATION: OONEMOJetc.
r•
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 71° Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
Pr<�wn
Property
StanOrd
Year
1507.2.4, R905.2.3
Physical Pmperties
ASTM D1970
2015
1507.2.5, R905.2.4
Material standard
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2019
3. REFERENCES:
Lnft
Examination
Reference
Date
Owens Coming
Declaration
Equivalency Declaration
08/06/2019
PRI (TST5878)
ASTM D1970
OCF-382-02-01
10/24/2017
UL LLC(CER9626)
Physicals& Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC(CER9626)
Physicals& Wind Resistance
20120516-112453
05/16/2012
UL LLC(TST9628)
Physical Properties
06CA20263
04/18/2006
UL LUC(TST9628)
Wind Resistance
IICA34308
02/19/2012
UL LLC(TST9628)
Physicals& Wind Resistance
4786093137
02/01/2014
UL LLC(TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC(TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TS19628)
Physical Properties
Classification letter
10/02/2015
PRI(QUA9110)
qualityContml
Service Confirmation
04/OS/2020
PRI(QUA9330)
quality Control
Florida BCIS
Current
DESCRIPTION:4. PRODUCT
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type
Product
Plant(s)
Material
DescriptionStandard
Starter Stin Shingle
H-TX, OR
Accessory
Starter
Starter Strip Plus
MN, OR
ASTM D3462
starter strips for asphalt roofshingles
SRS TopShleld Starter
MN, OR
Strips
Starter Shingle Roll
NH
ASTM D1970
minemisudaced, fiberglass -reinforce
self-adheringsBS modmM bltumenrtarter
Supreme'
GA, CA, CO, I -TX, NI, OH,
TN, OR, It
A5TM D3462
fiberglass reinforced 3-tab asphalt
roof shingles
Berkshire'
MN
ASTM D3462
fiberglass reinforced, 4-tab asphalt
roofshin les
Duration'Premium
CA, OR
Asphalt
Shingles
g
Duration' Premium COOL
CA
ASTM 03462
fiberglass reinforced, laminated
asphalt roof shingles
TruDeftnitlon' Duration'
IN, CM CO,1-TX, FL, Nl, OH,
MN, OR, GA, IL, TN
TruDefnition' Duration'
Designer Color Collectlon
Oakridge
GA, IN, CA, CO, H-TX,-TX,
FL, NI OH, TN
TruDefinition'Oakridge'
H-TX,I-TX
WeatherGuard' HP
TN
NEMO ETc, LL[ Evaluation Report 037540.02.11-1111
Qmpm .M.hnntadoam,ss 7a'EDITION (2020)FBC NON-HVHZ EVALUATION FL306]4-RS6
Owens Carving Asphalt Roof Shingles Revision 11: 12/11/ZO20
Page 2 of 10
ONFruiniptr
TABLE 1: ASPHALTSHINGIE COMPONENTS
Type
Product
Plants)
Material
DescriptionStandard
Berkshire HIPand Ridge
Shingles with Sealant
MN
Hip and
DuraRidgee Hip and Ridge
Ridge
Shingles with Sealant
MN
ASTM D3462
fiberglass reinforced, hip and ridge
Shingles
asphalt roof shingles
ProEdgee
GA, CA OH, OR
WeatherGuard' HP Hip and
Rid e5hingles
TN
5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications
TABLE ZA: WINO CLA59IFicA71oNs, AsP TSHINGLES
Product
FBC Table 1507.2.7.1 or R905.2.6.1
Supreme
ASTM D3361(F) &ASTM D7158(11)
Berkshire'
Duration Premium
Duration' Premium COOL
TruDefinition Duration
TruDefnition' Duration' Designer Color Collection
Oakndgea
TruDeOnRion Oakrldgee
Weathertivard* HP
5.5.1 Classification by ASTM D715g:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
NEMO mq LLC Evaluation Report 037M.02.12•g11
[ert�iWrtoJAUMONxmion Y32A56 7' EDITION (2020) FBC NON-WHZ EVALUATION FL106741136
Owens Coming Asphalt go& Shingles R¢Wsbn 12:12/11/2020
Page 3 of 10
ONEMOJetc.
TAgur 28: WIND CluSSDICATIONS, STARTER STRIPSAND HIP & RIWs
Type
Product
FBC Table 1507.2.7.1 or R905.2.6.1
Starterstdps
Starter Strip Shingle
ASTM D3161, Class
Starter Strip Plus
SRS TopShield Starter
HIP &Ridge
Shingles
Berkshire' Hip and Ridge Shingles with Sealant
ASTM D3161, Class F
DuraRidge° Hip and Ridge Shingles wRh Sealant
PmEdge°
WeatherGuard' HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Pagel of this Evaluation Report.
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use In reroof (tear -oft) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 Attetsoarr STARTED:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published Instructions, using minimum five (5) nails per strip.
Figure 1: Minimum Nallm& Starter Strip
Figure 2: Minimum Nailing, Starter Strip Plus
NEMO ETC, L C Evulanti Report 0379W.0212•N31
Cerfd ate ofAUMoNmrion p33455 7- EDITION (2020) I'M NON-HVHZ EVALUATION F406741136
Owens Carning Asphaft Roof Shingles Reeisron 11: 22/12/2020
Page 4 Pf 10
6.2.2
fkimojetc.
Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Figure 3: Starter Shingle Roll
6.3 ASPHA TSHINp1FS:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published Instructions, using
minimum four (4) nails per shingle In accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
Nasn.l Ma .... d.. A —pare
wind A.. High wind de.v.nea y
A/aa P/r/ vienrPf aermeix A.. ean,. =
+ ++
m E.poyun
E�p..icidn
Figure 4: Minimum Nailing, Supreme
(Standard Size)
N. .I M.merd or Arw p.r.
Wind Ar... High wind Menmey
Ares pen.iwrtee nnena,.x Aa.. viem.r hnn.
IAi * f+• IB 4• ,•
Le' Ex"Sure
Eapomcmn
Figure 5: Minimum Nailing, Supreme
(Metric Sim)
NEMO ETC, UC Evaluation Report 037M.M.12-KII
eenglmte ufA. d aden #3205 7'a EDITION (2020) FBC NON-HVHz EVALUAIION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 5 of 10
6.3.1.2 Berkshire..
SeabM Arip
Li III• MSaNIO
0N" 0Yf 9h' 0YY 1
Figure 6: 5-Nall Pattern, Berkshire
ONEMOjeft.
Srlen[stlip
1 /Le lvah iniatlor
Figure ): 6-Nail Pattern, Berkshire
sea6mnnp
Lzmatgyl4M
a s�rn p
1" l
re{"
1 ASOXaX roaTgsncenr
Cemmlo dahrMtle eVeM1a
Figure 8: Mansard or Steep Slope Pattem,Berkshire
NEMO ETC, LLC Evaluation Report 032940.02.12-101
Ceniift. ajAufFatlm(p002455 PE09ION 12020) FBC NON-HVHZ EVALUATION FLW674-1116
Owens Corning Asphalt goof Shingles Revision 11: 22/11120M
Page 6 of 10
ONEMOletc.
6.3.1.3 Durationa Premium, TmDefinitione Duration, Duration* Premium COOL & TruDefinition' Duration' Designer Color
Collection:
Figure 9: Standard 0-N211 Pattern, Duration
6-Nail Fastening Pattern
surewaMIDraanNpan WEq
r fiat 1Ypcal
Ir I.
F1 F� [L
8118" Sy8
Figure 10: 4Nail Pattern, Duration
Na Greater Than 21:12
...xae®lummnp area.mh
r Nen. ryq[m
tg^
Fgure 11: Mansard or Steep Slope Pattern, Duration
NEMD Err, LLC EvaluaUOn Repun 037M.OZ.1Z•R31
redlfWWojAuthozvIYna3W5 T'vEDITION (2020)FaC NON-NVNZ EVALUATION FI10167"16
Causes Corning Asphalt Reol Shingles Revision 11: 12/11/20M
Page 7 P110
6.3.1.4 TruDeFlnition' Oakridgen Oakride W:
4 Nil Paltan
Es4uwn,t.4daws
T
ISM &pow wtq
65N 6E
Eyacddndm66/Ryu:g. Cb✓
Expasltiott&66R{
Figure 12: Standard 4-Nail Pattern, Oakridge
6.3.1.5 WeatherGuarde HP:
u^
ONEMOletc.
6 Nall Pytum
Epuwnays6Naws
1'P T
5�CxpauN Cb� fi6N Fkpoww�
FkpaMG'ds66/B➢WB. Ex{oadvn G66/BWIp
Figure 13:6-Nail Pattern, Oakrdge
swensa w...we .
r-NAA Taw!
rmure av: mansara or meep-mope Pattern, Oakndge
6 Nei Pattern
EsWesre con 6 dakos NO 6 W from Late.
of dingle
6518'EFpowre 6Fas[emrs Om a 6 tl8oW. deb
Eaposign de 5 6g fig. 6 sujetAi4rss Pate iNaia k iFja
t•
rPi isµ
NR �pts
EANNaLAeers 6e mN &,kg Was Chase, Fee W in seemMtotde t�eo5o de $fee de 1191l
Figure 15: 6-Nail Pattern, WeatherGuard HP figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HIP
NEMO ETC, LW EnaluatlOn Report 039940.02.12-1131
CeniAmt,0fA,ehwaaWn R324S5 Y"EDITION (2020)FK NON-HVHI EVALUATION FL30674-Ri6
Owens Corniry Asphalt Roof Shingles Rentalon 11: 12/11/2020
Page 8 of 10
ONEMOletc.
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
D Berkshire' Hip and Ridge Shingles with Sealant and DuraRidgee Hip and Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
➢ WeatherGuard' HP Hip and Ridge Shingles and Prolidgee require minimum four (4) nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire- Hioand Ridge with Sealant and D rallid es Hip and Ridge Shingles with Sealant
Prevailing Wind Direction
Direction del vlenW predominance
6.4.1.2 WeatherGuard-HP Hip and Ridge Shi gles-
Fig. A
vrawp name
�—olr«mn°
W Ib
I I i
A I I
I
�pauw
Figure 19: Isometric View, WeatherGuard
Fig. B
ToPviaw
Vima superior
1 1"
2W
NYI
as p
awYYfprnYlg (ANNYi'
I
I
I.
AIL
I
Sim
I�
I
�.
12'
Figure 18: Plan View, Berkshire and Durallidge
Fig. C Hip & Ridge Shingle Fastening
TopVW
We WIY
r.
T R"
r r
1" 1
6" sapow.
ie +r —al
Figure 20: Plan View, Weathercivard HP Hip and Ridge
NEMO rTS LLE EValUatlen Report 037940.02d2-R31
Gsrsf.o JAodprkarbn Y32455 TTM EDITION (2020) Pat NON-NVK EVAWATION FE30674-1136
Owens corning Asphalt Roof shingles Revision 11: IZIIVZ020
Page 9 of 10
6.4.1.3 ProEdge- NNEMO I etc.
Prevailing
Wind Dirasclon Seale"gtnp
fi'Eapesure
Fetlen TL-
Feewl ne en wlih
lInK cement
Figure 21: Isometric View, ProEdge
SWedeld •—it'—=
Fr 1"
PRlben
IY &alanl
7A' B'EWspNip
Figure M: Plan View, ProEdge
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
Construction Materials Technologies, LLC-
- END OFEVALUATION REPORT -
MEMO ETC, LLC EvaluatiDn Repon 0373a0A2.12-R31
RMprurcofpuMwIIa(wn p33055 7- EDITION 120201 Fat NON-NVNI EVPLUATION FL10E)MRlb
Owens Corning Asphah Roof shingles Revision 11: 12/11/20M
Page 10 of 10