Loading...
HomeMy WebLinkAboutAPPROVED, 5 V Product Approval _fl 17022 1 5v crimp-1Florida Building Code Online Page 1 of 4 RegulationBusiness Professional BCIS Home : Lag In I User Registration Hat Topic Submit Surcharge Stats & Faces Publications FBC Staff BCIS Site Map Links Search F{ ritl2 Product Approval %. USER: Public User J Prod LLct Approval Menu > Product or Application Search > Application List > Application Detail ® FL # FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidatiori@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 0412212024 Validated By Zachary R. Priest, P.E. � Validation Checklist - Hardcopy Received Certificate of Independence FL170 2 R7 COI FL 17022.1 5 V CRIMP ssr. df Referenced Standard and Year (of Standard) Standard TAS 123 UL 1897 U L 580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqv2aBQplipQQ... 5/29/2018 Florida Building Code Online Page 2 of 4 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Of Method 1 Option D 08/18/2017 09/25/2017 08/28/2017 10/10/2017 FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr.od Verified By: Locke Bowden, P.F. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf Created by Independent Third Party: Yes 17022.2 2 - "5V Crimp" (R6) 0.032" Aluminum, 3/8" Rib height, 21" wide tapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.F. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.03 assembly in compliance with the installation method listed in ALUM ssr.pdf this report and applicable code sections of FBC. Refer to Created by Independent Third Party: Yes manufacturer's installation instructions. 17022.3 13 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.4 14 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.5 15 - "1 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.3 1.5 MECHANICAL seam 24 a ssr. df Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.3 1.5 MECHANICAL seam 24aa ssr.pdf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.pdf Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to IS/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf Verified By: Locke Bowden, P.E, 49704 Created by Independent Third Party: Yes Evaluation Reports F1 17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.pdf Created by Independent Third Party: Yes http://www.floridabuilding.org/pr/pr� aspx?paratn=wGEVXQwtDgv2aBQpl-QQ... 5/29/2018 Florida Building Code Online Page 3 of 4 the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 16 - "1 in. Nail Strip" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.7 17 - "1.5 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 113 - "EMAX Rib" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 19 - " PBR MAX" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 II FL 17022.E 1. NAIL STRIP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15132" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr. df Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions 1`1_17022 R7 11 FL 177022.8 EMAX Rib ssr odf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pdf Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssr. df Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road Tallahassee FL 3R2292 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Co ri ht 2 7-2013 State of Flori .:: Privacy Statemert := Accessibility Stateme k :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a publicrecordsrequest, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M9 Oj Cre&' Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paramwGEVXQwtDgv 2aBQpHpQQ... 5/29/2018 Florida Building Code Online Page 4 of 4 http ://www. floridabuilding.orglprlpr_app_dtl. aspx?param=wGEV XQwtDgv2aB QpHpQQ... 5/29/2018 FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel -Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wljurisdiction is allowed by other registered engineers. 5, Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 15I32" or greater plywood, or Wood plank 14- 318" Y h h l* J l Panel Overlap - `OFToNALSTRAT10N5 Panel Profile Nominal 12" Nominal 12" O.C. o.c- Fasten Y9 x 1-112" Min. or #10 X 1-112" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel \Ndth Refer to Table "A" for Spacing Along Panel Length Deck-15132" or greater plywood, or -Wood plank 2160 SW Poma Drive Palm City, FL 34990 Compliant with Florida Building Code 2017 (61" ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" o.c. 8" O.C. 6" ox. FASTENER SPACING (ALONG Panel width) 12" ox. 12" o.c. FASTENER SIZE #9 #10 12" o.c. 12" O.C. #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & 1897-041 Test Report CM893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY--UL 1897-04 is equivalent to test standard UL 1897-1� *Design pressure margin of safety 2:1 ..tiiiiriff.. Locke Bowden, P.E. does not have, not will acquire a financial in4w � n4 m?;Wfacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by air coiApar1VPMbiW64ture0, or distributing products under this report. m + • ;G / , / • !r(t�1 r�f0 t•aF�01-VVD s•�' , ,"I(S.!.a110