Loading...
HomeMy WebLinkAboutRevision - E-Calcs i OFFICE USE ONLY: FILL.. ��o Py DATE FILED: I'3' a-\ PERMIT# 2001-0629 REVISION FEE: RECEIPT# OV RECE1995 - PLANNING&DEVELOPMENT SERVICE JAN 1 3 2020 COUNTYBUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE Sf. Lucie County, Permitting �' FORT PIERCE,FL 34982-5652 (772)462-1553 FAX(772)462 570 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/S,fl ADDRESS: CALLE DE LAGOS 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: E-CALCS CORRECTED TO REFLECT TANKLESS WATER HEATER 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: ST.LUCIE COUNTY CERT.#: 8898 BUSINESS NAME orpora ion ADDRESS: N A80 b South US Ilwy. 1 Suite CITY; Fort St. Lucie STATE: FE ZIP: 3495 PHONE(DAYTIME): - FAX: 772) 878-7656 4. OWNER/BUILDER INFORMATION: NAME: Wynne Building Corporation ADDRESS: 8000 SouthHwy. I Suite CITY: rOrL 3L. 1,UC1CSTATE: FL ZIP: 34952 PHONE: (772) 878-5513 FAX: (772) 878-7656 5. ARCHITECT/ENGINEER INFORMATION: NAME: BRADEN&BRADEN ADDRESS: CITY: STUART STATE: FL ZIP: 34996 PHONE(DAYTIME): (772)287-8258 FAX: Revised 07/22/20 14 FORM R405-2017 I i JA N 3 2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDIN a UtQ Florida Department of Business.and Professional Regulation it Residential performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: VYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: �ST. UCIE COUNTY City,State,Zip: FT.PIERCE,FL, \� Permit Number! Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1 18 3 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1478.30 ft2 b.Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units,if multiple family 1 c.N/A I R= ft2 4. Number of Bedrooms 1 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling.Types (1336.0 sgft.) Insulation Area. a.Under Attiel4Vented) R=30.0 1306.00 ft2 6. Conditioned floor area above,grade(W). 1306 b.Knee Wall /ented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 7. Windows(128.9 sgft.) Description Area 11.Ducts R ft2 a.Sup:Attic,F. Attic,AH:Attic 6 120 a. U-Factor: Sgl,U=1.02 .76.04 ft2 SHGC: SHG0=0.29 b. U=Factor: Sgl,U=1.03 40.00 ft2 12.Cooling sys gems kBtu/hr Efficiency SHGC: SHGC=0.27 a.Central U 1 al 29.0 SEER:14.00 c. U-Factor: Sgl,U=1.02 12.85 ft2 i SHGC: SHGC=0.26 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric He Pump 27.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.701 ft. Area Weighted Average SHGC: 0.281 14.Hot.water sys ems 8. Floor Types (1306.0 sgft.) Insulation Area a.Electric I Tankless Cap:1 gallons b a.Slab-On-Grade Edge Insulation R=0.0 1306.00 ft2 EF:0.600 b.N/A R= ft2 . Conservation features None c.N/A R= ft2 15.Credits I None Glass/Floor Area: 0.099 Total Proposed Modified Loads: 43.81 PASS Total Baseline Loads: 45.95 II I hereby certify that the plans and specifications covered by Review of the plat sand . VE this calculation are in compliance with the Florida Energy specifications coered by this Code. calculation indicates'Compliance with the Florida Energy Code. PREPARED BY: Before construction is completedJAI . DATE: 4-28-202 this building will be inspected for compliance with Section 553.908 ,� # I I hereby certify Florida Statutes:that this building,as designed, is in compliance with the Florida Energy Co OWNER G BUILDING OFFICIAL: DATE: a DATE: I(� - Compliance requires certification by the air handler unit manufacturer that the a I.ir handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accorldance with.R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(i 402.4.1.2). l G�z� FILE C'OPY' R EVI VIw �u, CODE C,OMPLIANCE 4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017.@CG6th'JdlS�[®® 281F QQP 36I a o Page 1 of 5 �OCO L (f�f 2 FORM R4Q5=2017 INPUT SUMMARY:CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE CO Bedrooms:_ 1 Address Type: Street Address Building Type: User Conditioned Area: 1306 Lot# Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180 qStreet: THE COTTAGE :Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,.State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Init Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce . FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume' i 1 Entire House 1306 10576.2 SPACES Number Name Area Volume Kitchen Occupants: Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 234 1895.4 No 0 1 1 Yes Yes Yes 2 DEN 144 1166.4 No 0. 1 Yes Yes Yes 3 SINK AREA 42 340.2 No 0 1 Yes Yes Yes i 4 CLOSET 63 510.3 No 0 i 1 No Yes Yes 5 GREAT ROOM 452 3661.2 No 2 1 Yes Yes Yes 6 MASTER BATH 50 405 No 0 f 1 Yes Yes Yes 7 POWDER 25 202.5 No 0 1 No Yes Yes 8 KITCHEN 232 1879.2 Yes 0 1 Yes Yes Yes 9 LAUNDRY 40 324 No 0 I. 1 No. Yes Yes 10 STORAGE 24 192 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value AIea Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 31 ft 0 ��31 ft ___ 0 1 0 2 Slab-On-Grade Edge Insulatio DEN 24 ft 0 0 1 0 3 Slab-On-Grade Edge Insulatio SINK AREA 7 ft .0 42 ft2 ____ 0 1 0 4 Slab-On-Grade Edge Insulatio CLOSET 1 ft 0 63 ft2 ____ 0 1 0 5 Slab-On-Grade Edge Insulatio GREAT ROOM 32 ft 0 452 ft2i 0 1 0 6 Slab-On-Grade Edge Insulatio MASTER BATH 5 ft 0 101 ft2 0 1 0 7Slab-On-Grade Edge Insulatio POWDER 1 ft 0 25 ft2 _-__ 0 1 0 � I i 4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 �j ' FORM R405-2017 INPUT SUMMARY"CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge lnsulatio KITCHEN 38 ft 0 232 fie _--- 0 1 0 9 Slab-On-Grade Edge lnsulatio LAUNDRY 1 ft 0 40 fti ____ 0 1 0 !i 10SIab-On-Grade Edge lnsulatio STORAGE 21 ft 0 24 ft2 _ 0 0 1 ROOF / Roof Gable Roof Redl Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC... I V # Type Ventilation Vent Ratio('I in) Arla RBS IRCC I 1 Full attic Vented 150 1306 ft2 i N N CEILING # Ceiling Type Space R-Value Ins Type I Area Framing Frac Truss Type 1 Under Attic.(Vented) MASTER BEDRO 30 Blown 234ft2 0.1 Wood 2 Under Attic(Vented) DEN 30 Blown 144 ft2 0.1 Wood 3 Under Attic(Vented) SINK AREA 30 Blown 42 ft2 0.1 Wood 4 Under Attic(Vented) CLOSET 30 Blown 63 ft2 . 0.1 Wood 5 Under Attic(Vented) GREAT ROOM 30 Blown 452 ft2 0.1 Wood 6 Under Attic(Vented) MASTER BATH 30 Blown 50 ft2 0.1 Wood 7 Under Attic(Vented) POWDER 30 Blown 25 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 232 ft2 0.1 Wood 9 Under Attic(Vented) LAUNDRY 30 Blown 40 ft2 0.1 Wood 10 Under Attic(Vented) STORAGE 30 Blown 24 ft2 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar.. Below 1 S=>N Exterior Concrete Block-Int InsWASTER BE 4.1 18 0 . 8 �1 145.5 ft2 0 0 0.3, 0 2 W=>E Exterior Concrete Block-Int InsWASTER BE 4.1 13 0 8 I 105.1 ft2 0 0 0.3 0 3 N=>S Exterior Concrete Block.Int Insui DEN 4.1 12 0 8 l 97.0 ft2 0 0 0.3 0 _4 W=>E Exterior Concrete Block-Int Insul DEN 4.1 12 0 8 �1 97.0 ft2 0 0 0.3 0 . 5 S=>N Exterior Concrete Block-Int InsLSINK AREA 4.1 7 0 . 8 .1 56.6 ft2 0 0 0.3 0 _ 6 N=>S Exterior Concrete Block-Int InsGREAT ROO 4.1 22 0 8 I 177.8 ft2 0 0 0.3 0 _7 W=>E Exterior Concrete Block-Int InsGREAT ROO 4.1 10 0 8 80.8 ft2. 0 0 0.3 0 _ 8 S=>N Exterior Concrete Block-Int InsWASTER BA 4.1 5 0 8 40.4 ft2 0 0 0.3 0 9 N=>S Exterior Concrete Block-Int InsulKITCHEN 4.1 17 0 8 137:4 ft2 0 0 0.3 0 10 E=>W Exterior Concrete Block-Int InsuIKITCHEN 4.1 16 0 8" I 129.3 ft2 0 0 0.3 0 11 S=>N Exterior Concrete Block-Int InsulKITCHEN 4.1 5 0 8 40.4 ft2 0, 0 0.3 0 Ener Gau e®USA 6.0.02 Rev. 1 -FlaRes2017 FBC 6th Edition 1(201 7) Compliant Software Page 3 of 5 4/28/2020 2:17 PM 9Y 9 ( ) FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS f I Adjacent Space Cavity Width Height I Sheathing Framing Solar Below 12 N=>S Exterior Concrete Block-Int InsulKITCHEN 4.1 35 8 1 282.9 ftz 0 0 0.3 0 13 N=>S Exterior Concrete Block-Int InsuBTORAGE 4.0999 6 8 48.0 ftz 0 0 0.3 0 14 N=>S Exterior Concrete Block-Int InsuBTORAGE 4.0999 5 8 40.0 ftz 0 0 0.3 0 15 N=>S Garage Frame-Wood MASTER BE 11 30 8 0 240.0 ftZ 0 0.23 0.3 0 DOORS # Omt Door Type Space Storms UI-Value Width Height Area Ft In Ft In 1 E=>W Insulated KITCHEN None 32 3 6 8 20 ftz WINDOWS. Orientation shown is the entered orientation _> chan edl to Worst Case. / Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Areaf Depth Separation Int Shade Screening 1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N 32I I4 ft? 1 ft 5 in 1 ft 5 in None None 2. W=>E 4 Metal Low-E Single Yes 1.02 0.29. N 18`4 4 1 ft 5 in .1 ft 5 in None . None 3 _ N=>S 6 Metal Low-E Single Yes 1.02 029 N 18.4 ftl 1 ft 5 in 1 ft 5 in None None 4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N 400 ftl 12 ft 0 in 1 ft 5 in None None 5 S=>N 8. Metal Low-E Single Yes 1.02 0.29 N 6.9 ft 1 1 ft 5 in 1 ft 5 in None None 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N: 12If8 ft z 1 ft 5 in 1 ft 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter A yg. all Height Exposed Wall Insulation 1 280 ftz 280 ft' 35 ft 8.1 ft 11 INFILTRATION # Scope Method SLA , CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000257 881.4 48.38 90.99 f .0896 5 HEATING SYSTEM # System Type Subtype Speed. Efficiency I I Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.2 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:14 29I kBi u/hr cfm 0.8 1 sys#1 4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 FORM R405=2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType _ Location EF Cap Use: SetPnt . Conservation 1. Electric Tankless Garage 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS / --Supply--- ---Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Ha dler TOT OUT . QN RLF Heat Cool 1 Attic 6 '120 ftZ Attic 45 ftZ Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans: Cooling [[ ]]Jan Feb Mar Apr May Jun Jul Aug . Sep Oct NovDec Ventingg [X]Jan Feb Mar f Appr I May MJun Jul Au Sepp Oct EXj:Nov jj* DecVentin [[[[ ]II]Jan Feb Mar [Xl A r May Jun Jul [ Au Se [X]Oct [X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 1.2 Cooling(WD) AM 78 . 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 . 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68. 68 68 PM 68 68 68 68 68 68 68 68 68 68 68. 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68- 68 68 68 PM 68 68 68 68 68 68 .68 68 68 68- 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftZ 0 ft 0l.3 MASTER BEDROO Default(8 lbs/sq.ft. ftZ ft 0.3 DEN Default(8 Ibs/sq.ft. ftz ft j .i.3 SINK AREA Default(8lbs/sq.ft. ftZ ft ; 0.3 CLOSET Default(8 Ibs/sq:ft. ft2 ft U GREAT ROOM. Default(8 Ibs/sq.ft. ftZ ft i.3 MASTER BATH Default(8 lbs/sq.ft. ftZ ft I.3 POWDER Default(8lbs/sq.ft. ftZ ft j 0.3 KITCHEN befault(81bs/sq.ft. ftZ ft .Q.3 LAUNDRY Default(8 lbs/sci.ft. 0 ftZ O ft I C.3 STORAGE i I 4/28/2020 2:17 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition( 01 ) Compliant Software Page 5 of 5 i 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: w Design Location: FL,Fort Pierce 0 COMPONENT `AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed: Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill:plate shall be sealed. Cavities within corners and headers of frame walls. The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per,inch minimum. Exterior thermal envelope insulation for framed walls shall be installed.in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 9s. ' Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated.. Plumbing and wiring Batt'insulation shall be cut neatly to.fit around wiring andlplumbing in exterior walls,or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication ` exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub=floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. , Caulking or other adhesive sealants shall not be usedto fill voids between nkI and walls or celliagg.�_ a.In addition,inspection of log.walls shall be in accordance with the provisions of ICC-400. 4/28/2020 2:18 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017)I Compliant Software Page 1 of 1 i 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL).DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*=92 The lower the Energy Performance Index, the more efficient the home. 1.New home or,addition 1.' New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Attic 3.No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 1 13, Cooling system: Capacity 29.0 a)Split system SEER 14.0 5..Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1306 d)Room unit/PTAC EER e)Other 7.Windows,type and area a)U-factor:(weighted average) 7a. 0.543 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c)Area 7c. 128.9 a)Split system heat pump HSPF 8.2 b)Single package heat pump HSPF - 8. Skylights c)Electric resistance COP a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type,insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15,Water heating system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.60 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A.Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e)Dedicated heat pump with tank. EF 2.Masonry(Insulation R-value) 10A2. 4.1 f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1..Wood frame(Insulation R=value), 10131. 1.1.0 2.Masonry(Insulation R-value) 1062. 16. HVAC credits claimed(Performance Method) 11.Ceiling type.and insulation level a)Ceiling fans a)Under attic 11a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c)Knee walls/skylight walls 11c. 19.0 d)Multizone cooling credit d)Radiant barrier installed 11d. No e)Multizone heating credit f)Programmable thermostat No "Label required:by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has compiled with the Florida Building Code,Energy Conservation,through the above energy saving features which will be installed (or exceeded).in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: A Address of New Home: THE COTTAGE v ���'� City/FL Zip: FT:PIERCE FL 5 1 4/2B/2020 2:21:49 PM EnergyGauge®USA 6.0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1