HomeMy WebLinkAboutAPPROVEDwindow door scheduleA FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zane - 10% of least horizontal dimension or 40% of the mean roof hainht whirhr-vwr is smallor hart not lace than Aa1. of 1-1 hnri—i.i 6mcn6 nr 4 f+
OPENING
LOCATION
NUMBER
(Looation)
Garner Zone
or Interior
IS THIS A
WINDOW
OR DOOR
GLAZING
TYPE
PRODUCT
ACCEPTANCE
NUMBER
PRODUCT APPROVAL
APPROVED PRESSURE RATING
REQUIRED OPENING
DESIGN PRESSURE
MAXIMU
M
TESTED
SIZE
ROUGH
OPENING
DIMENSIONS
MULTIPLE
WINDOW
ARE
SHUTTERS
REQ YIN
+ PSF
()
(-) PSF
() PSF
{_) PSI
MULLION
REQ YIN/NA
1
End
Door
'" Larfli l6
FL 11103.1
60
60
36.6
-46.7
96.96
71 x79
YES
No
2
End
Window
I" t.ami lc
FL13010.4
55
55
38.8
-5 I..1
4802
7004
YES
No
3
End
Window
Wg`I.aniiI{l
FL16736.2
60
60
36.2
j -45.8
111,,63
1.09x61
YES
No
4
End
Window
I"l,amila
FL13010.4
55
55
37.4
-48.3
4802
109x38
YES
No
5
End
Widow
""" Lami "`
FL 16736.2
60
60
36.2
-45.8
l l l x 63
109x61
YES
No
6
End
Window
1" t.umi tG
FL 13010.4
55
55
37.4
-48.3
4802
109x38
YES
No
7
End
Window
7/8" 1:anii
FL 16177.1
70
70
40.2
-53.8
52x62
12x61.
No
No
8
End
Window
7/8"1—i
FL16177.1
70
70
40.2
-53.8
52x62
12x61
No
No