HomeMy WebLinkAboutBuilding PlansBottom Cord
of Truss
plate
yp. d.w.
Is 24"o.c.
d Grade
t. sill plate
)ase
Hard Coil
12"o.c. max.
Concrete
Foundation
Interior Wall Section
Non Load Bring. Wall Option
INTERIOR WALL FRAMING
Non Load Bearing:
Metal Studs (25 Gauge). Crimper may used
in lieu of screws. Walls to stop at Bottom Cord of
roof trusses.
Fastening Requirements
Top Track to Truss Cord / Roof Framing with I" "s" screw at 24"o.c.
Sill Track to cons. Slab with DN37P8 "Hilti" Shot 16"o.c.
or Stub Nails 16"o.c.
Studs to Top & Sill Track with One 3/8" "S" pan head screw each side
Wall Key
Load Brng. Frame
New Frame Walls 0
(Non Lead 6rng.)
Column Key
Grout Filled CMU Cell
with (1) #5 Vert. Rebar
�❑ Grout filled CMU Cell
CONTRACTOR TO VERIFY ALL WINDOW,
DOOR, AND MASONRY OPENING SIZES
PRIOR TO ORDERING WINDOWS AND
DOORS.
34'-8"
Installation Notes
1. Installation of U lintels must comply with architectural
and/or structural drawings.
2. U lintels can be field out to the required length.
3. Cast in place concrete may be provided in composite
U lintel in lieu of concrete masonry units.
4. The exterior surface of U lintels installed in exterior
concrete masonry walls shall have a coating of stucco
applied in accordance with ASTM C-926 or other
approved coating.
5. Concrete masonry units used in composite U lintel shall
e laid in a running bond.
6. Shore composite lintels as required.
7. J.lintels are manufactured with a 5 1/2" long notchat
oth ends to accomodate vertical cell reinforcing and
rout.
Composite U Lintel Materials
1. Grout per ASTM 0476 fg=3000 psi with maximum 3/8
inch aggregate and 8 to 11 inch slump.
2. Rebar per ASTM A615 Grade 60
3. Concrete masonry units (CMU) per ASTM C90 with
minimum net area compressive strength = 1900 psi
4. Mortar per ASTM C270 Type M or S
CONTRACTOR TO VERIFY ALL WINDOW,
Second Level Floor Plan DOOR, AND MASONRY OPENING SIZES
scale: 1/4" = 1'-0" PRIOR TO ORDERING WINDOWS AND
DOORS.
Cast Crete Lintel Schedule All Rebar to be #5 Grade 60 min.
MARK
LENGTH OF
LINTEL
ALLOWABLE
GRAVITY LOAD.
APPLIED
GRAVITY LOAD
ALLOWABLE
UPLIFT LOAD
APPLIED
UPLIFT LOAD.
BEAM SPECS.
L-1
13'-4"
1075
450
606
300
81`16-1B/IT
L-2
11'-4"
1366
450
798
300
81`16-1B/1T
L-3
4'-8"
4567
935
1960
476
8RF14-1B/1T
L-4
T-8"
1568
302
931
163
8RF14-1B/1T
-L-5
6'-0"
3480
323
1880
209
1 8F16-16/17T
L-6
6'-8"
2661
348
1634
300
1 81"16-1BAT
L-7
T-4"
2661
592
1634
245
8F16-1B/1T
Min. Beam depths shown, beams may be increased without comment
Add (1) #3 vertical rebar 24"o.c. in lintels over 24" deep.
Safe Load Table Notes
m. (U redd.
n°an;n,°i#5„ea"
1. All values based on. minimum 4" nominal bearing.
—
ea
Exception: Safe loads for unfilled U lintels must
F-fi11ede'nm
be reduced by 20% if bearing length is less than
w° n al
6 1 2.
CM
a,A..
�
F I
8F16-1 B/1 T
2. N.R. Not Rated
rnaed
3. Safe loads are superimposed allowable loads.
roaee
T qn;ry°f#s
4. One #7.rebar may be substituted for two #5.
#5,eba, at bottom minalJ
nt ntei°aal, nman '," bat t°°
rebarin fl inch U lintels only.
B" N°mfnal
7 5/8"
5. All safe loads in units of pounds per linier foot.
Lintel Type Designation
6. All safe loads are based on simply supported span.
7. Safe load ratings based on rational design analysis
per ACI 318 and ACI 530.
Scope of Work
New Two level CBS Utility Building
with pre engineered Roof and Floor
Trusses and a concrete foundation.
Building Data
Occupancy Type: Group U
Construction Type: V
Number of Stories: Two
Area Tabulation
Total 1,041 s.f.
Climatic & Geographic Design Criteria
Building Code
6th Edition Florida Building Code
2014 National Electrical Code: NFPA 70
Design Loads
Roof Live Load: 20.0 p.s.f.
Floor Live Load: 40.0 p.s.f.
Wind Speed: 150 MPH
Wind Importance Factor: 1 A
Building Category: I
Wind Exposure: B
Internal Pressure Coefficent: .18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
Weathering: Negligible Termite Area: Very Heavy
Flame Spread Index & Smoke Developed Index
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
U Z
y N O
:ode
� 0 a ca
a P E
` rn a
i In a>
©I� ! >'
U. 4)
OL
3
C/)
[W
O
M
L
W
z
M
0
LL
LO
N
act
CO
•
(D
Wp
n
ao
r
0
J
W
'4
Q
Q
z
_U
W
>
o
LO
W
N
M
V J
a'
Ct3
U
C
�
O
CV
-gym.
—
r
� Z
r
t°
W
U
LU
cal
r
Q
00
°
G')
• Ell I I IB B B a -------------- Ells B '
® Lt'---— — — — — — — — — --J
• New Location of UP 120140 Roll Up Door n
the existing water,M
u softner lines "� ,.
Colo
L-4 do B Future
Lift
Platform
❑
B
N
II
II
O U
6'-0-
3'-2"
4'-0"
4'-8" I
14'-6"
LL.
B
II o
C)
,
o
® 2
W L.
6068
Existing
Well Head
i i c
L1
I I
Garage II
Garage
Q 0
L-4
B
s'-o" Ceiling
B
i
II
_D
Q m 0 U
8'-0"
A
> J
C>
-
Cling.
C) C:L. +i
p Storage
80A I
W !� C7
E P (2) 2 x 12 with 1/2" plywd. I I
= O co
flitch plate on 4 x 6 p.t. I I
CD
oD
00
column I I o
C)
C'7
B
B
B
II r
Q
ed.L-3
RL-5 i
i 3o6a
II o
II
F'
o
I
I
i
LU
o
-------- BBB B B 0, -----------------
BIDE]
---------------- _--- ------ L-6 L-2 date revision
o L-1 0
Cones
Pad Cons.
Pad
drawn
checked
QQ�daatt
� e
2'-0" 10'-0" 2'-0" 1 12'-0" T-0" c) p�/j� [/S/2p i 3/5/2020
12 6'-8 28'-0" REVIEW © `� 7 as Scale
noted
4'-0" 34'-8" CODECO Job number
O WA 19077
ST. LUCIE
First Level Floor Plan AUNTY sheet
scale: 1 /4" = 1'=0„ BO(iC A-1
FILE Copy
GENERAL FOUNDATION NOTES
Concrete shall be a minimum of 5" thick over clean, compacted,
termite treated fill and 6 mil polyethylene vapor barrier.
If concrete slab contains 6" x 6" 10/10 WWM provide 1 " coverage
Concrete shall have at minimum compressive strength of not less
than 3,000 p.s.i.
All 90% hooks are to be extended 10" minimum beyond the turn.
Field bends are to be done cold and the diameter of the bend,
measured on the inside of the bar, is not to be less than six
bar diameters.
Minimum coverage for rebar shall be 3" in footings and 1 1 /2" in
bond beams. Hooks may be rotated horizonitally if required to
achieve minimum coverages.
Reber overlap shall be 48 bar diameters. 30" for #5 rebar
The foundation design assumes that the soil has a minimum
load carrying capacity of 2000 p.s.f.
In the event the soil bearing capacity falls below 2000 p.s.f. This
foundation plan may be superceded by Foundation Design Engineer.
Satisfactory compaction test of fill does not verify lower soils are
adequate.
All specifications and dimensions to be verified by contractor.
All exterior slabs shall slope a minimum 1/8" per foot for drainage
FORMWORK & SHORING
No structural concrete shall be stripped until it has reached at least 80% of
the 28 day design strength.
Design, Erection, & Removal of all formwork, shores, & reshores shall meet
meet the ACI Standards 347 and 301
Contractor to verify all building setbacks prior to the start of construction.
A formboard survey shall be submitted to the building department for
approval prior to pouring concrete.
SOIL STATEMENT:
Foundation has been designed fora soil bearing capacity of 2000 ps.i.
Fill shall be laid in layers of 18". Each layer to be compacted to 95%
compaction,
If the contractor encounters, while digging the foundation, any
discrepancy to suggest the soil may be inadecuate, he must
immediately report it to the owner and the Architect or Engineer
so as to order a soil boring test.
Dowel Rod Repair Note
In the event vertical steel has been omitted from the down
Pour locations, drill 5" into concrete (no closer than 3 3/47
from edges and 5" from ends of cap walls) Remove dust
per manufacturers instructions and use Two part epoxy to
anchor the #5 rebar in place. Use either -Hilti C-100" or
Simpson Epoxy -Tie.
F-1
F-2
F-3
24" x 18" mono. footing
1 i3"' x 16" mono. footing
with (2) #5 rebarcont.
24" x 18" mono. footing
with (3) #5 rebar cont.
and curb 8„
~
with (3) #5 rebar cont.
- _
4'
18„
5„
16„
9
24"
24"'
18,
MONO.- EDGE FOOTING
CURB FOOTING
STEP FOOTING
F-4
F-5
F-6
18" x 16" mono. footing
with (2) #5 rebar cont.
18" x
with (
16"" mono. footing
t #5 rebar cont.
8" x 8" mono. footing
with (1) #5 rebar cont.
5"4
5„
8„ 5
J7-
8",
18"
18„
I,
INTERIOR FOOTING
- STEP
FOOTING
THICKENED EDGE
(2) 2 x 12 beam
with 1/2"plywood
flitch btwn. Fasten
with 16d 6'"o.c.
g'-0"-- - staggered
(2) MTS18 Straps with
(14) 10d x 1 1/2` nails
per strap at each end of
beam
4 x 6 P.T. Column
ABU46 Post Base with
(1) 5/8" dia, x 7" Wedge
Bolt to concrete and (12)
16d nails to column.
0.Q0, -I
F.F.E.
i
F-7
_=L_8
18"x 18"x 18" L3-
pad footing with
(1) #5 rebar 6"o.c. V-6-
each way
Interior Brng. Column Detail
Product Approval Affidavit Form
Category
Subcategory
Approval
Numbers
Manufacturer
Model Number
Glass
Type
Attachment Method
Building Design
Pressures
Product Rated
Design Pressures
EXTERIOR DOORS
Swinging
g
FL#: 20468.1
Therma Tru
Fiberglass
N.A.
Head: 4" from comers. Jambs: 4-from corners
Use 1/4" dia. Tapcons with 1 1/4" embedment
and 16""o.c. max.
in concrete
` +33.5 -36.3
+50.0 -55.0
Double Swinging
FL#: 15037.2
Therma Tru
Fiberglass
N.A.
Head & Sill: 6" from corners & 3"& 7"from center.
from comers and 13.75"o.c. max. Use 1/4" dia
1 1/4" embedment in concrete
Jambs: 6"
Tapcons with
+33.5-36.3
+50.0 -55.0
Garage Overhead
FL#: 16546.4
Clopay
Model 73 W6
N.A.
(1) 5/16" x 1 5/8" lag screws. (9) total periam
+27.9 -31.2
+36.0 -42.0
Steel Rooling
Door
FL#: 12765.3
Janus International
3100
N.A.
3/8"dia. x 4-Powers Wedge Bolt 12"o.c
+24.3 -32.0
+36.0 -41.0
WINDOWS
Fixed
N.O.A.
18-0430.05
PGT
PW7720A
Impact
Head Sill: 6"from corners and 12"o.c. Jambs:
comers and 12"o.e. Use 1/4" Tapcon with 1
embedment into concrete
6"from
3/4"
+33.5 -36.3
+/- 80.0
ROOFING PRODUCTS
Metal Roof Panels
FL#: 11560.5
Metal Sales Mfg.
Image II
#10-12 Pancake Head Screws 1" Long at
6"o.c.
-57.5
-102.7
Underlayment
FL#: 16048-R6
Tri Built Materials
i Built Smooth
TrHT S/A
Direct Attachent to plywood)
SOFFIT
FL#: 13389-R5
Certain Teed
Corp.
Vinyl Carpentry
Triple 3-1/3
1 1/2'"x .125"shank dia. & min. 7/16"h
ails . F Channel 16"o.c., Center 10"o..,
ad dia. roof
End 10"o.c
-760
+246.0
4'
20'-8-
T-8" 6,-8,"
2"dia. PVC drain
line to outside.
`Coordinate with
/ owner
12'-0" 2'-0"
T-4- 12" 12
12"
F-6 IT
F-6
Slope for o
F
6 4
Garage Dr.
I
v
F-2
0.0'
;,
o
El
00bl
o F_1 0o
F-1 olio
-
F-600,
-I----------
r M
-----_ F-1
-
New Location of
the existing water
F_r3l softner lines
I i
ih
I F-7
,
I
I
I L-J IF-41 IF-4IEll
1
-4
I -4' t
z
tt
4'-0„ 4'-4", I I 4,_4", 2,". I w
13'-4"" I ❑�
M
slope
1
F-31
IF-1
I
I( I I(
o I
L J
010
L-
F
0
N
-
o f-2 10
1
t o
N
�
I
i-
N
1
1
1 5" 3000# CONCRETE WITH M
I
c
Q
6" 10/10 WELDED WIRE MESH r
co
F^6
1
Existing
1 Well Head
I OVER .006 VAPOR BARRIER
ON CLEAN, COMPACTED,
1
cn
M
I TERMITE TREATED FILL
0 ASSUMED F.F.E. 0.00' F-7
-4"
slope
-4'
F-31 -1
i
L -J
M
I
12'-8"
I
(
o
i
in
-IF-2
-
I
N
I
0
Em
Ell
o
IF-1
6'-8"
I
1
F-5 slope
F-1I Slope for
Garage Dr.
Slope for I
Garage Dr,
N
1
o I_----- - --
--- - J
100
cc
N
�•
o00 F-1 00o
F`1 o00
- -
F-6
0.0'
0.0'
IF-6
F
6
4
L
-
T-0"
6,-8 1
4'-0"
Foundation & Footing Plan
scale: 1 /4" = V-0
2" v.t.r
to sewer
system
Plumbing contractor to provide a
water hammer & shut off valve at
each fixture
Insulate all hot water lines
Sanitary Riser Diagram
F-6
8-
10'-0" 12'-0- T-0"
28'-0"
34'-8"
PLUMBING NOTES:
Plumber to consult with contractor and equipment ordered
for rough in dimensions.
Verify all dimensions with the floor plan. The floor plan
dimensions dictates all other dimensions on other sheets.
Do not scale drawings, if any conflicts arise, contact the
Architect or Engineer for clarification prior to construction.
All sanitary lines 2" or less shall have a slope of 1 /4" per
foot minimum.
All sanitary lines above 2" shall have a slope of 1 /8" per
foot minimum.
All Irrigation lines are to be 3/4"diameter minimum.
Main water line to be 1 "diameter minimum.
Provide drain line to the North from Toilet Room to the Lift Station
ci
Q
O LU M
0 Z
c� U_
C -
f/) cp
N w 1j 00
N a
J LPL
• N Q FU v
U
C0 Z °"
U W
O �
J CD
�
4) LV
Q� Q
is U
> LO h It
4
• �.. 0 L
t400
_ U Z N
W
:3 < U)
Q co
00.0
M
T
O
LL
w O G1"
c� Q o
Q
W .L V
Q m -�
O > -J
o C;
LU
_0 00
U N
H
w
date revision
drawn
S.I.
checked
sJ.
date
3/s/2020
scale
as noted
job number
19077
sheet
A-2
pke co
�w Ay
North Elevation
scale: 1 /4- = 1'-0-
I
1 -1
L
lFi
JL
ED
L❑
Do
El [I
no
El El
Do
I
South Elevation
scale: 1/4" = V-0"
corner bars at beam
(outside only)(2) corner
bars at footing (min.) —
vert. dowel lapped with
wall reinforcing, all
laps 30- (min.)in grout
filled cell
Corner Reinforcing Detail
I
I
L---------------------I
8'-0- T.O.B.
_
I
I
®®®®®
Open
®®®®
F.F.E.
0.00'
all corner bars to be the
same size, number, and
spacing as horizontial bars
in footing, beams, and walls
East Elevation
scale: 1/4" = 1'-0""
West Elevation
scale: 1/4"" = V-0-
8"" x 16"" C.M.U. WITH CELLS FILLED
i WITH GROUT & (1) #5 VERT.
DOWEL
F ..
x
w �...
P.T. 2 x 6 AT (3) SIDES OF
OPENING, FASTEN TO BLOCK
d
WITH 1/2" x 6"
aREDHEADS
WITH MIN. 2"" DIA. x 1/8""
0
WASHER (TYP.) SPACING AS NOTED.
O
DOOR SIDES
a
12"" FROM ENDS AND 16"o.c. MAX.
Sectional Garage Door Buck Detail
METAL ROOF PANELS
ON "PEEL AND STICK" UNDERLAYMENT
OVER 5/8" C.D.X. PLYWOOD —\
SEE CONNECTOR
SCHEDULE --\
GALV. DRIP EDGE ON
1 x3P.T.ON2x8
CEDAR FASCIA -\
2 x 4 BLOCKING CONT.
BETWEEN TRUSSES ALONG —
FASCIA & WALL & AT CENTER
OF OVERHANG
2 x 4 bottom cord bracine
Bottom Cord Lateral Braci
VINYL VENTED
SOFFIT
GRADE
N
•
F-1
•
12
5
PRE ENG. WD.
TRUSSES 24"c.c.
T.O
(2) COURSE BOND
BEAM WITH (1) #5
REBAR FILLED WITH
GROUT EACH COURSE
8 x 16 x 8 C.M.U.
WITH #5 VERT. DOWEL
IN GROUT FILLED CELLS
"ROVIDE CASTCRETE
RECAST LINTELS ABOVE
LL OPENINGS
18'-8"
OF BOND BEAM 10'-4""
(2) COURSE BOND
BEAM WITH (1) #5
REBAR FILLED WITH
GROUT EACH COURSE
5" 3000# CONCRETE WITH
6" 10/10 WELDED WIRE MESH
OVER .006 VAPOR BARRIER
ON CLEAN, COMPACTED,
TERMITE TREATED FILL F.F.E.
(3) #5 REBAR
CONTINUOUS
Two Level Wall Section
C
N
N
OCrM
L.
'R
J
w
Z
v
M
C�
lf)
b.0
U
.N
UJ
0
a
LO
O
00
0
J
Q
N
v
ZEF
�-
U
W
o
'
O
cL)
w
''N
VJ
to
~
>
cu
U
W
'C
r�
/
Ln
N
I
�y
T C
00
LL
U�Z
N
coLU
T
U
LL
w
O
iE
C7
Qb.0
i
Q
L
>
U
Q
00
U
>
J
N
0
N
LLI
=
N
O
U
I..L
00
CV
Q
L1J
In
drawn
s1
checked
s.l.
date
3/5/2020
scale
as noted
job number
19077
sheet
A-3
F4Fc
Opp,,
Ceramic Tile
Shall be installed in accordance with ANSI A108.1, A108.4, A108.5
A108.6, A108.11, Al 18.1, All 18.3, A136.1, & A137.1. Fiber mat reinforced
backer shall be used behind wall applied ceramic tiles in the tub
and shower areas and conform to ASTM C1325. Per Durock,
cement board exceeds ASTM C1325.
Gypsum Note
Gypsum board shall conform to ASTM C22, C475, C514, C1002, C1047
C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential
code. Per USG, Wallboard conforms to C1396.
Gypsum Board & Gypsum Panel Products
Gypsum board and gypsum panel products shall be applied
at right angles or parallel to framing members. All edges and
ends of gypsum board and gypsum panel products shall
occur on framing members, except those edges and ends that
are perpendicular to the framing members. Interior gypsum
board shall not be installed where it is directly exposed to
weather or to water.
Wall and ceiling gypsum board shall be fastened with screws
s aced at 12-o c Screws for attachin sum board and gypsum
12"" TYp•
O.H.
r�
5/12
5/12
5/12
5/12
5/12 5/12
5/12
r
v g gyp
panel products to wood framing shall be Type W or Type S in
accordance with ASTM 01002 andshall penetrate thewood not
less than 5/8- inch 05.9mm) Gypsum board and Gypsum panel Roof Plan
products shall be attached to cold formed steel framing less scale: 1/8- - V-0-
than 0.033- 0 mm) thick shall be Type S in accordance with
ASTM C1002 or bu le head st le in accordance with ASTM C1513
g Y
and shall penetrate the steel not less than 3/8"" to 0.112"
(1 mm to 3mm) thick shall be in accordance with ASTM C954 or
bugle head style in accordance with ASTM 1513. Screws for
attaching gypsum board or gypsum panel products to structural
� }
, + Calculation
Vents
Attic V e n l.s V a I c u I a i o n
insulated panles shall penetrate the wood structural panle facing,
not less than 7/16-o.c. 01.1mm).
Gypsum board used as the base orbacker for adhesive application
Attic Area: 1,041 s.f. / 150 = 6.94 s.f. required.
of ceramic tile or other required nonabsorbent finish material shall
conform to ASTM C1396, C1178, C1278. Use of water resistant
gypsum backing board shall be permitted on ceilings. Water
Soffit area = 179.3 Lf. x 2.0 = 358.6 s.f.
resistant gypsum board shall not be installed over a Class 1 or
Class 2 vapor retarder in a shower or tub compartment. Cut or
Venting Provided:
exposed edges, including those at wall intersections, shall be
sealed as recommended by the manufactuer. Water resistant
gypsum backing board shall not be used where there will be
Vented Soffit System provides 10 sq. In./ft.
direct exposure to water, or areas subject to continuous high
humidity.
179.3 If. x 10 sq. in. = 1,793 sq. in.
Cold Formed Steel Note
1,793 sq. in. / 144 = 12.4 s.f.
Cold formed steel framing supporting gypsum board and gypsum
Total Ventilation Provided: 12.4 sq. ft.
11/ ) 'd ' th
panel products shall be not less than 4 (32mm wl a In e
least dimension. Non Load bearing cold formed steel framing
shall comply with AISI S220 and ASTM C645, Section 10. Load
bearing cold formed steel framing shall comply with AISI S200
and ASTM C955, Section 8.
90 DEGREE HOOKS
Wood Framing Note OVERLAP 25" MIN.
Wood framing supporting gypsum board and gypsum panel
products shall be not less than 2`` (51 mm) nominal thickness
in th least dimension except that wood furring strips not less
than 1- by 2"" (25mm x 51 mm) nominal dimension shall be
permitted to be used over solid backing or framing spaced
nnf mnre than 94-n r.. (61 Omm)
Connector Notes:
Do not substitute connectors
Do not sheath trusses before all straps are in place
Attach valley trusses and piggy back trusses, if present,
to main trusses per truss manufacturer drawing.
Truss to truss connection by truss company, installed
per manufacturers specs.
I forces perpendicular and parallel to wall has been
Lateral f r p p
considered (less than 300 p.l.f.)
Contractor to approve temporary bracing to prevent toppling
of trusses, see HIB-9.
Other specs, if different from above, have priority.
A.T.R. = All Treaded Rod
Drill and Epoxy Set all A.T.R.
Use either -Hilti"` 0-100 or Simpson Epoxy Tie Epoxy
Provide equal number of studs under girders equal to
the number of plys.
3/6"" bead h
GENERAL ROOFING NOTES
(back
caulk (back bedding) behind
buck to prevent liquid passage
Roofing to be composed of and attached to pre manufactured
wood trusses as follows:
set flange in continuous
bead of caulk across the
Felt underlayment (min. ASTM 0 226 Type 11) with 4"" min. side and
entire face of buck
end laps, fasten with coorosion resistant annular ring shank nails
CBS
at 6""o.c. in laps and in staggered rows spaced 12"`o.c. in field.
If roof pitch is < 4/12 install (2) layers 15# felt.
If roof pitch is 4/12 or greater, install 0) layer 30# felt.
w
p
Min. 1 1 /4- embedment
at windows and min.
7/16"" o.s.b. sheathing or equal installed with staggered joints & GI clips
a
° .
1 1/2' embedment at
nailed to trusses with 8d corrosion resistant annular ring shank nails
ov y
a':
_'a
° e sl. gl. doors
spaced max. 6""o.c. throughout, except max. 4-o.c. at gable ends.
0o�
o
°
All roof trusses are to be pre -manufactured assemblies provided by
E
a
a licensed wood truss fabricator with seperate drawings and data
m d
d. • n
prepared for actual project conditions by a Florida registered
N «�-O
b
-°
professional engineer certified for truss design. Any deviation from
° o
the proposed plans as shown regarding placement or bearing shall
be brought to the attention of the truss engineer prior to fabrication
of the trusses. The truss manufacturer's certified layout shall govern
after fabrication.
The handling, erection, and fixing of wood trusses shall be in
accordance with the specifications contained on the certified mfgr's.
drawings and data.
perimeter caulk
1/4- max. struct shim
All engineered headers and truss hangers to be provided by the
Attach p.t. bucks
truss manufacturer.
with 8d coil nails at
12" o.c.
Splitting or cracking of structural components due to installation of
attach as per
hardware is not permitted.
Typ. Alum. window
manufacturers
jamb or sliding glass
product approvals
Unless otherwise noted, the installation of specified hardware shall
doorjamb
conform to the truss manufacturers installation instructions and
standard practice.
NOTE: Method of attachment and
Gunable sealants shall comply with
waterproofing procedures are the
ASTM C 920 Class 25 grade or
same at poured cone rete sill.
greater for properjoint expansion
BUCK ATTACHMENT NOTES
and contraction
Coat Bucks with Protecto-LWM200 Waterproofing
AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH
after they have been installed and Chaulked
BUCKS TO BLOCK WITH 1/4- DIA. TAPCON SCREWS
WITH 2 1/4""EMBEDMENT INTO C.B.S. SET A 6- FROM
Window & Door Flashing
Detail at CBS Wall
CORNERS AND AT 12""o.c. MAX.
PROVIDE 3/8"" CONTINUOUS BEAD OF CAULK (BACK BEDDING)
Includes Buck Attachment Method
BEHIND BUCK TO PREVENT LIQUID PASSAGE.
Alum. (window
SET THRESHOLD IN BEAD OF CAULK ALONG THE ENTIRE
LENGTH OF TRESHOLD TO PREVENT LIQUID PASSAGE
USE 'STRUCTURAL" SHIMS DURING DOOR INSTALLATION
corrosive resistant WOOD AND/OR CEDAR SHIMS SHALL NOT BE USED.
Tapcon concrete
srews installed as
specified in window manufacturers product SHEATHING NAILING NOTES
approval
,-window sill Nailing Pattern
Zone 1: 8d at 6""o.c. field & 4""o.c. edges
Zone 2: 8d at 4""o.c. edges & field
Zone 3: 8d at 4""o.c. edges & field
Pneumatic Nails
II Q S Pneumatic or mechanicaly driven nails will
III+ =I be accepted under the following conditions:
HORIZ. TIE BEAM STEEL Gunable sealants shall comply with u�
SEE WALL SECTION FOR ASTM C 920 Class 25 grade or ° e 4 •a ; • Min. nails size 8d or larger ring shank with
STEEL REQUIRMENTS greater for proper joint expansion Min. shank diameter:.113
and contraction precast Min. Length: 2'
cone. sill Min. Head Diameter:.280 Full Round
Min. Ring Diameter .012 over shank dia.
frame
3/8"' continuous bead of
caulk (back bedding) behind
shim to prevent liquid passage
1 /4- struct. shi
set flange in continuous
bead of caulk across the
entire face of buck
perimeter caulk
r'UUKtU UILLL.J VVI I r1 rvw ,. IV w cv nu 1sa yc, awn
(1) #5 BAR CONTINUOUS
FROM BEAM TO FOOTING Typical Precast Conc. Sill Detail Gun nails shall be permitted as an
acceptable fastener from any manufacturer
Nailin Schedule
Change in Bond Beam Elev.
Connector Schedule
Truss
Bearing
Truss
Connector
Qnty'
Connector
Fasteners
Point
Uplift
ID
Uplift
All
trusses.
ALL
<1000
MTS18
1
1000
(14) 10d x 1 1/2""
to Frame
All
trusses
ALL
<1800
HETA16
1
1810
(9) 1Od x 1 1/2"�
to CBS
Missed Tie Down Strap Note
In the event the Tie Down Strap has been omitted from the
Layout location, install one HTSM20 strap at the proper location
Fasten with (4) 1 /4"" x 2 1 /4"" Hex Head Titen screw to C.B.S.
and (10) 10d to truss. MAXIMUM UPLIFT 1175 lbs.
Wind Zones - Roof
Wind Zones - Walls
ROOF & FLOOR DIAGRAM
Use sheathing with #8 gun nails at 6-o.c.
at supported panel edges and #8 gun
nails at 6""o.c. at intermediate supports.
IROOF SHEATHING TO GABLE END FRAME
Use #8 gun nails at 4""o.c.
EXTERIOR SHEATHING
Use #8 gun nails at 4""o.c. at panel edges
and #8 gun nails at 4'o.c. at panel top and
bottom and 6" o.c.. in field
STRUCTURAL NOTES:
All reinforcing steel shall be high strength billet steel and shall
conform to ASTM A-615 grade 60 specifications. Lap continuous
reinforcing 48 bar diameters or 30- in beams and in slabs. Lap
bottom steel over supports and top steel at midspan. Hook
discontinuous ends of all top bars. Reinforcing steel shall have
a minimum of 1 "" concrete cover, or as follows:
BOTTOM TOP SIDES
Seams: 1 1 /2- 1 1 /2- 1 1/2-
Slab
on Grade: 1 1 /2'" 1" _
Structural Poured: 3/4"" 3/4""
Poured Walls: _ _ 3/4""
Slabs exposed
to the weather 3/4"" 1
Reinforcing steel shall be detailed and fabricated in accordance
with the "Manual of Standard Practice of Detailing Reinforcing
Concrete Structures" and the current -ACI Building Code 318""
All structural steel shall conform to current ASTM Specification A-36
All wood in contact with masonry shall be pressure treated or approved
seperating material.
All dimensions shall be verified in field by the contractor. If there are
any discrepancies the Architect or Engineer shall be notified before
proceeding.
No slump over 5" shall be permitted for any structural concrete without
the Architect or Engineer approval,
All Design and Construction shall be inaccordance with the current
American Concrete Institute (ACI). and the American Institute of Steel
Construction (AISC), The Florida Building Code and all applicable
local codes.
Structural Concrete shall attain a minimum ultimate compressive strength
(Fc') in 28 days as follows:
Column Footing and Wall Footing: 3000 p.s.i.
Column and walls from foundation to roof: see column schedule.
All other concrete: 3000 p.s.i.
Footing sizes and reinforcing are based on allowable soil bearing
capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this
is not the case, the Architect or Engineer shall be notified before
proceeding with the work,
Timber (Heavy Timber Construction)
(a) Truss manufacturer shall submit a signed and sealed shop
drawings by a registered Engineer.
(b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i.
(c) Roof members should be secured to the beams or other
structural components with hurricane anchors for wind uplift.
All wood members shall have a minimum fiber stress in bending
of 1200 p.s.i. with 1/360 max. deflection.
All bolted connections shall be 1/2" Cadmium plated or better.
Lag bolts to be used only in shear connections with minimum
4�" threaded penetration past steel plate.
Lag bolted conditions shall be drill tapped no larger than the
internal thread diameter and shall not be hammer driven.
Under Girder Trusses provide equal number of studs as girder
plys at frame bearing locations
GENERAL REQUIREMENTS
All work to be as per the current edition of the Florida Building Code
and meet or exceed all applicable local requirements.
General contractor is responsible for all labor, materials, utilities, testing,
waste removal, storage, securing of site, accomodation, transport/freight,
and all other cost related to the completion of this project., unless explicitly
identified here.
Owner is responsible for all municipal related charges such as impact
fees, and water connection, except building permit fees, which are to be
included in the construction bid.
General contractor to check all drawings for errors and ommissions and
bring them to the attention of the architect prior to starting any work, or
ordering any materials of the respective division of work. If such errors
and ommissions are not reported In writingto the architect, any resulting
damages or costs shall be born entirely by the general contractor.
Architect is not responsible for the contractors method or means of
construction.
General contractor is to keep the site in a clean and safe state through
out the course of construction. On building turnover, general contractor to
clean all surfaces so as to be free of dust, grease, stains, scuffs, etc.
Unless otherwise noted, the installation of specified hardware shall
conform to the manufacturers instructions and standard practice.
All plans and drawings are not considered complete until they have been
reviewed and approved by the Building Department
and the building permit has been issued.
U
l
Q
[V
0
M
'1_
V'
W
Z
le
C7
UL
In
N
ai
Uco
tt
,N
W
�,0
0
J
11 ''
-.
04
Q
N
.ri
Z
U-
LU
�
o
a
CD
(D
>
LU
'-F^,
V J
ar
O °�
U
LL _N
W 0 a
C7 LPL
Q > O
Q m U
> J
Q o +i
w
t� 0 N
_ y 00
U L1� °°
G'V
Q
H
w
0
date revision
drawn
s.l.
checked
s.l.
date
3/5/2020
scale.
as noted
job number
19077
sheet
A-4
Upper Roof Framing Plan
Scale: 1/4`= V-0""
JU
o'
0
0
0
3
J5
�✓9
9
=
FLE
4 0
o
`v
2'-0-
Bed
4
3
FGEA
Open
m
w
J7
FLD
F4F
7
FLD
FLB
FLB
J7
FLB
J7
FLB
3" ledger top @ 10'-3"
FLB
J7
FLB
J7
e ^ .
G
�
FLB
J7
FLB
J7
5
�P
FLB
FLB
;-J34--LB
28-00-CC
6-08-00
3=
Lower Roof & Floor Framing Plan
Scale: 1 /4""= V-0"
IN
T
Fill two courses of
CBS along Landing
Ledger solid with
Grout
m
I y
o �
Exterior
CBS wa
Top of Grout Fil
Perimeter Beam
- � 10'-3"
(2) 2 x 8 p.t. Ledger
Fasten to CBS 1/2" dia.
8" long wedge bolts
24"o.c. staggered
Ledger to CBS Detail
T-2" 9'-2"
(5) Treads at 10" (10) Treads at 10"
1.2""
Wall Mount Handrail
Ir"n. 36"" above Tread with
1 1/2"" Grip Surface
1 1 /2- min. from wall
See Ledger
Detail
(2) 2 x 12 Beam-/
with (2) 2 x 4 Ledger
attached
2 x 12 Stringer /
Three Places V
0) at each side
and (1) in center
1/2" d.w. on underside
of stringers & landing
Stair Section
Scale: 1/2""= V-0"
Simpson HU48 Hanger
with (14) 1 /4-x 2 3/4"
Titen to CMU and (6)
I Od to beam
0
0
Handrail at 36- above
Tread with 1 1/2" Grip
Surface.
1 " Nosi
2 x 4 p.t. plate fastened
to concrete with cased J
hard coil nails. Plate cont.
along with of stairs
(2)2x8
Ledger
Cover Joists with
2 x 6 Joists
x 3/4""T&G plywood
16"o.c.
c Glued & Screwed to
floor trusses per Nail
Schedules
(2)2x12
4x6p.t.
Simpson HU48 Hanger
Column
with 04) 1/4"x 2 3/4"
Simpson HUSC210-2
Titen to CMU and (6)
.
Hanger with (8) 16d to
1 Od to beam
Column and (8) 16d to
Beam. Typ. (2) places
Stair Landing Plan
Scale: 1/2""= 1'-0-
10`6""h l
9'-0"
2 x 4 cont. Horiz.
fasten with (2) 3""—
wood screws at each
intersection
3/4"T&G plywood
Glued & Screwed to
floor trusses per Nail
Schedules
pre engineered
trusses 24-o.c.-
1 /2"d.w.
0.00' $
TOILET
ROOM
2 x 6 cont. cap
2 x 4 Vertical at 48'o.c.
Fastened to the side of
the floor truss with (6)
16d nails
2 x 4 to extend up from
the top plate
2 x 6 cont.
(2) 2 x 4 plate
\_with SP4 with
(6) 10d x 1 1/2-
at each stud
\-1/2" gyp. d.w.
2 x 4 studs 16-o.c.
2 x 4 p.t. plate
with SP4 with
wood base (6) 10d x 1 1/2-
1 at each stud
see footing
details 1/2" dia. wedge bolt
with 3- x 1 /8 washer
7- embedment 24-o.c.
Bearing Wall Detail
AND LOFT SECTION
METAL ROOFING 12
ON ""PEEL AND STICK"" UNDERLAYMENT
OVER 5/8" C.D.X. PLYWOOD 5
SEE CONNECTOR
SCHEDULE
GALV. DRIP EDGE ON
1 x 3 P.T. ON 2 x 8 PRE ENG. WD.
CEDAR FASCIAS TRUSSES 24'c
2 x 4 BLOCKING CONT.
BETWEEN TRUSSES ALONG -
FASCIA & WALL & AT CENTER
OF OVERHANG
VINYL VENTED-/
SOFFIT
GRADE
8'-0„
(2) COURSE BOND
- BEAM WITH (1) #5
REBAR FILLED WITH
GROUT EACH COURSE
8x16x8C.M.U.
WITH #5 VERT. DOWEL
IN GROUT FILLED CELLS
5" 3000# CONCRETE WITH
6" 10/10 WELDED WIRE MESH
OVER .006 VAPOR BARRIER
ON CLEAN, COMPACTED,
TERMITE TREATED FILL F.F.E.
gk — 0.00'
t� i
l F-2/
One Level Wall Section
U
Q
0
"
O
co
' R
v
W
z
�
M
LL
LO
C-
(n
N
co
co
_
a
LO
a3
00
0
J
L.L
04
Q
N
z
d
U
VQ3
LUa
O
_
Q
>
J
LO
LU
12�
m
d
4)
a--)
>
U
w
Lo C
rl-
~
O
N
2oZ
T
r
o0
ci
N
�a
00
rr
M
T
O
U
LL
L.
w
O
L.
a
,
n'
w
L
Q
>
0
Q
W
C)
U
C7
j
0
J
Lu
M
0
w
=
N
O
N
Q
Lu
Q
drawn
s.l.
checked
s.L
date
3/5/2020
scale
as noted
job number
19077
sheet
A-5
®4PP
--------------------I
gfi verify
location
Future
Lift
gfi
Loft
It
gfi
To switch at
Entry Door
Second Level Electric Plan
scale: 1/4- = V-0`"
ELECTRICAL LEDGEND
—E:}- SURFACE MOUNTED LIGHT FIXTURE
) SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE
® EXHAUST FAN OUTLET =0 DUPLEX OUTLET
_W SWITCH El PUSH BUTTON
-W THREE WAY SWITCH
aW
NOTE: RECEPTACLES IN BATH AREAS TO BE 45"' A.F.F.
ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING
OUTLETS THAT ARE NOT GFOI MUST BE AFCI.
TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE
PHASE 15 & 20 AMP BRANCH CIRCUITS
Electrical contractor to verify all equipment loads prior to
start of construction. Electrical contractor to recalculate
electrical schedule if loads are to be modified
Electrical Notes
1. All loads to be checked by a Florida Licensed Electrician
2. All work to meet the National Electrical Code
3. Calculations and panels below are for sizing conduit and overall
building load requirements only
4. Ensure min. 36" clear between equipment and disconnects, Typical.
VAI 01191uMl.[e]100
ELECTRICAL WIRING SHALL BE COPPER - TYPE THHN OR TYPE
THW FOR WIRING WITHIN BUILDING. TYPE THWN UNDERGROUND
OR ON BUILDING EXTERIOR. CONDUIT SHALL BE EMT WITHIN
BUILDING, PVC UNDERGROUND, GRS OR SCHEDULE 80 PVC FOR
SERVICE ABOVE GROUND.
INSTALL WIRING FOR WATER SOFTNER IN 1-MIN. CONDUIT
First Level Electric Plan
scale: 1/4- = 1'-0_
Replace the Existing
200A U.G. Meter Can
with 240/120V 200A
1 Phase Meter/Main
Combo.
To FPUA Pad —
Mount Transformer
ON
200A
Main 2-PVC with
(3) 2/0 CU &
(1) #6 CU Ground
#6 CU to (2)
8'-0- Rods
G.E.C.
GARAGE
EXISTING PANEL
200A 80A
M.L.0 1? Space
40 Space Load Center
Load Center
1 1/2- PVC with—/
(3) #4 CU & (1) #8 #6 Ufer
CU Ground Ground
Electrical Riser Diagram
Electrical Load Calculations
1041 Living S.F. at 3 VA
3123 watts
(3) Garage Doors
3600 watts
Well Pump
1200 watts
Water Softner
1200 watts
One Bath
1500 watts
Lift Station
2000 watts
Total 12,623 watts
12,623 W / 240 V = 52.6 Amps
Use 80A Service
Well Pump
Equipment
U
Q
(/)
cV
M
I—
'R
v
W
Z
-qt
M
C7
�
LO
N
i
•�
W
Q
N
d
I
LO
00
r
0
J
LL
.4
V°?
z
LU
d
�
_U
O
_
Q
J
(/a
LO
LU
m
41)
U)
�~
>
(Q
U
W
M •-1
LOC
T�
O
T
CV
r
Z
U
f/)
i
_
00
T
III
O
LL
W
�
_U
a
A
C7
LPL
C
Q
>
O
U
�My�►
W
Q
U
C7
>
J
Q
`U
(D
V
W
�
='10
�
co
O0
U
N
Q
W
Q
drawn
.J.
checked
.J.
date
3/5/2020
scale
as noted
job number
10077
sheet
A-6