HomeMy WebLinkAboutProduct Approval; Roll-up Exterior Door AssembliesFlorida Building Code Online Pagel of 3
�"•Yi rrT' "fr�J 7,�M1i � �.� £i� � � _ } ..}.� z �,'�� r `+*, s, , a � Yt �'�� }��°"'�ti', v ¢.
�r ri
BuSmess Pr�ofesoa�al�gaii��, ��� ;I
,
,,,, „fit r:7,"�"�;� �tfT,'9t'u.>;+•:`��7u;.^s.k�-�st„��,.r �,b;,�t. �. I R9Pkt1o;�= aar,rruepa oai�+o�i•ic orra" zcu.Ttcf�n�rx;8CIS Home Log 1. User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Unks Search
• jProduct Approval
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL12765-R4
Affirmation
2014
Approved
Janus International Corporation
134 East Luke Road
Temple, GA 30179
(770) 562-2850 Ext360
curts@janusintl.com
Curtis Schroeder
curts@janusintl.com
Curtis L. Schroeder
134 Janus International Blvd.
Temple, GA 30179
(770) 562-2850 Ext360
curts@janusintl.com
Jake Lyons
134 Janus International Blvd. i
Temple, GA 30179 i
(770) 562-2850 Ext304
jakel@janusintl.com I
Exterior Doors
Roll -Up Exterior Door Assemblies I
Evaluation Report from a Florida Registered Architect or a -
Licensed Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Joseph H. Dixon, Jr
PE-7768
National Accreditation and Management Institute I
12/31/2018
Gordon Thomas, P.E.
❑ Validation Checklist - Hardcopy Received I
FL12765 R4 COI 29018 cert of ii. inden.odf
Standard
Year
ANSI/DASMA 108
2005
ASTM E330
2002
TAS 201
1994
TAS 202
1994
TAS 203
1994
FILE COPY
http://v ww.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgsmFBeODh9XI... 9/20/2016
`gig ��,�-
I" -
Florida Building Code Online rg ®ef— Page 2 of 3
Sections from the Code
91 affirm that there are no changes in the new Florida
Building Code which affect my product(s) and my product(s)
are in compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity OYes ONo ON/A
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL # Model, Number or Name
12765.1 Series 1100
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +24.4/-27
Other. Not for use In High Velocity Hurricane Zones
FL12765 R4 COC 35008 self affirm 12765 R3.Ddf
Method 1 Option D
03/10/2015
03/10/2015
03/15/2015
Series 1100 - 26 Gauge Door Assebmly Max Size: 8'-B" x
14'-0"
Installation Instructions
FL12765 R4 II 29018 Dwq T1012 Rev A.Ddf
FL12765 R4 TI 29018 install 750 1100.gyf
Verified By: Joseph H. Dixon, Jr. 7768
Created by Independent Third Party: No
Evaluation Reports
FL12765 R4 AE ER-09-0008-11,odf
Created by Independent Third Party: Yes
12765.2
Series 1100
Series 1100 - 26 Gauge Door Assembly Max Size: 10'-0" x
14'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12765 R4 II 29018 Dwq T1013 Rev A.Ddf
Approved for use outside HVHZ: Yes
FL12765 R4 II 29018 in II 750 1100.Ddf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +19.4/-22.7
Created by Independent Third Party: No
Other: Not for use in High Velocity Hurricane Zones
Evaluation Reports
FL12765 R4 AE ER-09-0008-R.odf
Created by Independent Third Party: Yes
12765.3 / I Series 3100
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +36/-41
Other: +36/-41 psf at 12'-0" wide. Varying loads are
shown for widths 8'-0" to 16'-0". Not for use in High Velocity
Hurricane Zones
12765.4 1 Series 3100
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +35/-38
Other: +35/-38 psf at 16'-0" wide. Varying loads are
shown for widths 15'-0" to 20'-0". Not for use In High
Velocity Hurricane Zones
Series 3100 - 26 Gauge Door Assembly Max Size: 16'-0" x
20'-0"
Installation Instructions
FL12765 R4 II 34012 Dwq T1004 E.Ddf
FL12765 R4 II 34022 Mod 3100 inst instr.pdf
Verified By: Joseph H. Dixon, Jr. 7768
Created by Independent Third Party: No
Evaluation Reports
FL12765 R4 AE M3100 FL12765 T1005G P2.odf
Created by Independent Third Party: Yes
Series 3100 - 26 Gauge Door Assembly Max Size: 20'-0" x
20'-0"
Installation Instructions
FL12765 R4 II 32041 FLT1005-F 0002.Ddf
FL12765 R4 II 34022 Mod 3100 inst instr.Ddf
Verified By: Joseph H. Dixon, Jr. 7768
Created by Independent Third Party: No
Evaluation Reports
FL12765 R4 AE 32041 ER-09-0007-R2 120112 0005.Ddf
Created by Independent Third Party: Yes
12765.5 I Series 750 112ries 750 - 26 Gauge Door Assembly Max Size: 3'-0" x
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +35/-45
Other: Not for use In High Velocity Hurricane Zones
Installation Instructions
FL12765 R4 II 29018 Dwq T1000 Rev B.Ddf
FL12765 R4 I1 29018 install 750 1100.Ddf
Verified By: Joseph H. Dixon, Jr. 7768
Created by Independent Third Party: No
Evaluation Reports
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?pararn=wGEVXQwtDgsmFBcODh9XI... 9/20/2016
Florida Building Code Online
Page 3 of 3
FL12765 R4 AE ER-09-0007-R.pdf
Created by Independent Third Party: Yes
12765.6
Series 750
Series 750 - 26 Gauge Door Assembly Max Size: V-0"
x12'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
I-LI2765 R4 I1 29018 Dwg T1001 Rev B.Ddf
Approved for use outside HVHZ: Yes
FL12765 R4 II 290 8 " stall 750 11QQpdf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +19.9/-24.4
Created by Independent Third Party: No
Other: Design pressures listed Is at test width of V-0". For
Evaluation Reports
pressures versus widths, see Table 1, Page 4 of evaluation
FL12765 R4 AE ER-09-0007-R.edf
report. Not for use in High Velocity Hurricane Zones.
Created by Independent Third Party: Yes
12765.7
Series 750
Series 750 - 26 Gauge Door Assembly Max Size:8'-8" x
12'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12765 R4 I1 29018 Dwo T1002 Rev B.odf
Approved for use outside HVHZ: Yes
FL12765 R4 II 29018 install 750 1100.odf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +24.4/-27.0
Created by Independent Third Party: No
Other: Not for use in High Velocity Hurricane Zones
Evaluation Reports
FL12765 R4 AE ER-09-0007-R.odf
Created by Independent Third Party: Yes
12765.8
Series 750
Series 750 - 26 Gauge Door Assembly Max Size: 10'-0" x
12'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12765 R4 II 29018 Dwg T1003 Rev B odf
Approved for use outside HVHZ: Yes
FL12765 R4 II 29018 install 750 1100.odf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +19.4/-22.7
Created by Independent Third Party: No
Other: Not For use in High Velocity Hurricane Zones
Evaluation Reports
FL12765 R4 AE ER-09-0007-R.odf
Created by Independent Third Party: Yes
12765.9 Series 850-S Series 850-S, 26 Gauge Door Assembly Max Size: 8'-8" x
12'-0"
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL12765 R4 II 29018 Dwg T1006-S Rev B.Ddf
Approved for use outside HVHZ: Yes FL12765 R4 II 29018 Install 850.odf
Impact Resistant: Yes Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +46/-54 Created by Independent Third Party: No
Other: Not for use in High Velocity Hurricane Zones Evaluation Reports
FL12765 R4 AE E11-09-0007-11.0f
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 201Z licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please dick hem .
Product Approval Accepts:
®M M
-Credit Card
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsmFBcODh9XI.
fr 9 ��ETC1�
9/20/2016
eRACKtTATTAC—
C°ICRETFIR—aLOCJt:POM'EPS WEDOEIOLT, 3Sx tau- LOW
alEEt:31E1, —T, aLa. ybte x ,-1M LQU
J gUiPNT4l
�ivArnoou
-
>a�
T
i MEAO a10P -
ol�oc
STEEL
JAM85
moMAx
°Iv Na
Ircx.Hr
ICtEAR OPe1cW1
axnAN
I
1
SIDE VIEW
%��QN H. D�XO� •,��
``���
' CEN 3
No. 7768
�: STATE OF of
A ¢1 t11¢
•.
�v
ry FOPwa HN OPEM ANeTa '# V,
F� P P; �4 NAL
,b101RRPE PF PNAN aI1NE:a•VE• e.�, . ���/ 1 i t 11111 .lose woN* ROE P wJe s�olw
1.125�1U R1.632
T COMMERCIAL
T WINDLOCK
MATERIAL: GW
gD1 I ASTM A653
STRUCTURAL STEEL
GMDE 50. CLASS 1
250 -�
100
570
115
(11 (iAy Ii go*
�+- 3.038 ---�
SEE SHEET 2 FOR NOTES
REQUIRED
OPDBlO
NExIHi
VEttTIGV.
IIEADRocM
NORRONIAL
Nr °RPou
TIPEU
ar
to-
rs
OVEN
rn
21•
21-
lvR
1P0
OVER
IPP
n1RU
Zo-,w
2,•
ea•
OVER
1.
TNRU
Z
Iwo
OVER
1aa
1
t&0
OVER
190
W.
ma
olwoE
e�we,mAvn
cYA was
1-- UP1 IARGEMIOtpIfNOPLATE
1V _ (NSTAIL°N BPTN JAL®S FPR 1
J°ALesP"n`o�P"c4A�L41t �;TEEL
I L
THESECONFDENTMOOCUMEWSSUBMRTE°BYJANV3CONFANW'OIOUnO OFAP0.0PNETMYMTURE
AIq MAYHOT ae n{FR°°yC®oR usFDT° MMufACTUxE NIYInIN° NPAitT OR N WIOLE FORANt
PUPPDSEO E PRE314TM138 IBIECE9 3 FOBWYREL OF MWMATAN TWL VIITK3Uf
THEEXPI1E1r PERMDBiON OF JANUSYA1x;H IMY RECALL DPCUMFIRSATANY THE
1.t4
-__ Am><.>m — DRAWING RELEASE OM
087 - r 104 carp A GUIDE ATTACH AT TOE 11.13-03 DM
J I �tiy 8 ADD GUIDE OPTMN3 h13U1 DM
-1 -_tTI PTEEL) m C NOTE REVISION B-17m CS
oR uoLe: wirN D AOPEn-rtwtc.Er oPTON tao-tz Cs
RW NELDEO I2-28-fAI CS
2XR.1W IT T ryiEfU .
.,ES
ALL COMPONENTS SHALL BE
ASTMASS3 STEEL WM°N
WINDBAR FY•33 KR DALVANUED A : • •, / ®t1iO.0 wY
PEP ASTMASSt SAS//
1.500
�
-T
I e'
.105 F 1 L . 2.000
III.1r..
1.145 I i"--- .• ~
GUIDE
InSOPLUPWELD CPNCpEIE/FAIEOBLOCR JAMafi
rm,:DZM.3 N3�,,. P„A.„Y,E�aPLi
EEL-9
'SELL DptlaIG SCREW
our LNA%O1
•^�' 13_OA .tl Oal GUiDENWN11N4,DETAIL
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES. TOLERANCES LISTED BELOW. urtaL3awvwe:
DECIMAL FRACTIONS ANGLES HOLE DIAMETERS
dvwe
xim 40.0w-14116- •/-0130' UNDER 0Z51 :o BECKY NELSON
XJ= N-0,W51 .Gam
0.251 -O.SOD ..X3 DON MILLS
OVER 0.6DO u1wYEa
DON MILLS
oen°PLA,MaENJI
JANUS INTERNATIONAL CORPORATION
135 JANUS INTERNATIONAL BLVD TEMPLE,GA 30179
770562.285WFax 770.562.2264
O 2014 Janus Inte national Cwporallon All Rights Reserved
CERTIFIED WIND LOAD RATED
26 GA SERIES 3100 DOOR ASSEMBLY
1-31-03 MAX. SIZE 10'-0" X 20'-0'
131-03 B MM....,..LA T1004 E
1-31-03 was NONE mKei. 1 m 2
L
N
L '
Ex6TN09FFEL
t-- AVr YTIKXiA55
srniw vWu 1•
m Ir OF YAY
L CUIITAN
Le• ,--� - L wroLDoaAnAw
+v1rH lEA01 YIr0
ruETs,-1Dm.-Eo
L WFmIOCRm EVGROiF¢R
cwmwATzw
OP "1
w•]17otF) w-lvl)
w,101110.H
V.-11®I0.F1 CiNTAN C
v-tw,
STEEL `W1S5-lM GUB� NWM SNONT!
nAFm _
IA.1 � �' HnRenB
f _ sEIFmnIxFD
SCREW
®1TM0.4 LLA%
BBOO IDGTKRE)
GLRTAN
It1N01DCxe ATTACH
wTM]Elol vlE•e
RNEISII`CCWTEp
[wND10CR m EVEwo1>aL
cmlRucATRN
OPT19j
CONICRf:TF1fRLE0 BLOCIL JAKBS
RN OUIOE SHOWN
GEWRAL NOTES
1, THIS ROLLLP DOOR SYSTEMS DESNiJED NACCORDANCE MIH Tiff FLdi[DA BURDN(i WOE (FBCI AND
NIERNATIONAL BWLWDq OOUE ID10E THE PEWNEDp6gNVSNDPRESSURF9 FOIL A DDOR N ANY
PMTCLAAR BULDNOSHALL BE OEIFRIRNFOINALWRDANCEWLTH SECTION IMW THE FSC. N CODE
MUSDITIONS OUTSIDE WNO
OF FIARILVA REOLFMEO DESIGN PRESSURES LMYBEDETER6 DN
CE 1Hn1 AOCORDANSECTIDN INS OF THE IBC OR WnH ilE LOLL BIFI-COM N EFFECT FOR THE
SFECPC LOCAT-L
2 TT6�W MSBEENSUCCEWF=YTE9TEDACCOR MMTHEIIMFORMSTATICNRPREBSIAiE
TEST PER ASTM E=ANDANSUDtSMA 1m TO SAFRYRE913TA Po$rWE AND NEOATNE VANOL LOAD AS
NOTED BELOW. A TEST LOAD OF 15X DESM LOAD HAS BED]USED.
DESIGN LOAD-�1-00 PSF
LOADS FOR BUEONO 01>-cN SHALL BE DETEAAINEO SY A PROFESSONIL ENOSVEER USNO
METS 4U WNO SPEEDAAO D6ADNORREII SuLn oop MAYB!V9W WHEIIE THE tR9GN LOAD
MEEISOR EXCFE06 THE DESIGN LOADFOI] 11IE BULOD100PENNO
A. SIPERII.wOSED LOADS ON THE LIME. FROM THIS DOOR ARE DESINED AS WAND VF )BREW.
CONTRACTORS L HAVE BUaDNG ENGSE RVERi ADEOLLYCYOF BMLDNG STRUCTURE TO RESIST
MPERRPOSEOLOADSVAW.
S. ALL WaO1NGSOMLLEE PERFOnLffDITYOUALFEDWFLOERSNACCORDANCEVILM A.W89PECiF10ATO1B
UIEST EpigaALL WELpNO ELECTRODES SHNLCOOFORM ro A.WS.A1.I GRADE E->0.
0. D001091NNBEPROVIDEDVRfII LC0IIECNAM51.6 AT Tiff OP1pHOF 1HE OWNER
1. ALL BOLTSAND WASIER39/WLBE GALVANI1ED00. STANt c"e S1EEllHFHA WOIJNTENSaE SiRENOM
OF N 16L
S. DESM BAEFD ON CFAnF1EDTE91NDlABORATORE9IVC. TESTREP SAG. OTLA-IDHW FORTIAOUON
DUDE ATTALTITEMTTO L SAND RD.CTA-11BFLVFDR TOE O<OLIDEAnXNMENTTojA ,
a ANCNgi NOTES:
A EL6EDMEMLENOTH DOES NOT BTCLUDE STUCCO NV6IL
B. FOR HOLLOW LAASMJRY. FDL ALL CE119 mANCuOR WI11I ]soppy r.ROUT,
C. ANLTION SOW T BE PATAIi Fn NAlLOR W. M WIM WNUFACTWERS SPECi1CxTpNs.
10. OOOR OPERATgN 7YFE To BE PUSH-W.IMFIDCINN, OR ELECTRIC.
It, GUW TO JAMSATTACLLFETFTFASTEl1ERS BEORI F-FRON1 ROORANO A'saOW TOPOF THE WALL OKWk
12
. TEBrppOq WALLOPINWOBDE: I]'-PxC•0•.
olko
,,. ��Q •,-.....--• • ti
O •v%cElY
No. 7768
'a STATE OF r
�.4%- -ft OR101;••' .
r
- - ll;-
"Fill rltuti�� vDWCCHC¢�e
ORRlEO BLOb(LtM6-- I
I �
_-/N�iBTY T166�1
-.Rp.AM1 TWCMh35 ]TIA•m tr O.C.IIAx V*.,
wnmIEMBEOMNroF
surNwsEwTET1W.
� z r O lroc. LNz
1 CMTAN CURTAN r
W00lDf�SATTACN w90LOCx9AlTACN L
L2I-�- �]EACAl Y18'O PoV�E ]FAd YIYB If-yg-
� snx coA-Eo e-awaNTEo
i � oPDlNOwoM _ I + I
wMIOULmfVERIO- WNNOCK mEYERYOTIEA
I COPRINAIpN WNTNNCEET CO•mvOATtON _ 1
OPTIONS WNCRETFIFGLEOBLOCK h-mm
RH OVIDE MOUNT EHOWN
��--�-„aV- � •1A•TGi6
I auv. eTEE.N NACcdlN�ucA I
I MINABitl AFMDpD .�!•
ah4f1� THEE Yr PoATA]
WEORlOLT919 FYI
N EIlLOYMIN
CpRAfIEPi HI"FE Ys'
7E0.THNPDLT9 MOMNw
Bf[EL- M fbSTW E111511BTI,
u CNLMFt®PPORDIFf.
TNEBE CONFpEMNL DOCULOTS 6UBLOTIED BY LINOS CONTAN NFORYAnON OFA PROPRETARY HATUIIE
ANO AMT NOT BE PFPRogA:EOOR USED TO MANUFACTIFLEANYTTNO NPART OR N wNOLE FOp ANY
PLIRPO9E O-M TIVJ!THATWHLTINFECESW FORMYREATroNOF B1090FENONEME WRHOUT
TIE ElO'RESS PEREL6,SION OF JANUS WIOC11 VAY pECALL DOCUMEIITSATANY la1E
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCITES TOLERANCES LISTED BELOW
DECIMAL FRACTIONS ANGLES HOLE DIAMETERS
XJGr ooz" .I-tn6- .I.O. 7n UNDER 0.251
IXXI y-0.ow -om]
0.251-0.500 oam
OVER 0,500
BECKY NELSON
DON MILLS
ALLOWABLE TRANSVERSE DESIGN WIND LOADS
I.e.,
MAX
DOOR
WIDTH
8'-0'
MAX
DOOR
HEIGHT
20'-0'
DESIGN LOAD
POSITIVE
PSF
77.4
DESIGN LOAD
NEGATIVE
PSF
86A
91-0'
20'-0"
61.3
68.9
10'-0'
20'-0"
50.2
56.7
11'-0"
201,0"
42.1
47.7
12'-0'
20'-0"
36.0
41.0
13'-0"
20'-0"
31.3
35.8
W-V'
20'-0'
27.5
31.6
15'-0'
20'-0'
24.5 1
28-1
16'-0'
20'-0'
22.0
25.3
�KaR1NRCp1CRE1E
vtBwFioaTHpOP _ .� \\
1-31-03
1-31-03
1.31-03
u1� J M� yr FO.YHte
tIDE1TC ueFBIRNTM
CAxTCR ry{TIRIFE )T
STEEL V UDO'SlYa6 WSKKptRitt!'
JANUS INTERNATIONAL CORPORATION
135 JANUS INTERNATIONAL BLVD TEMPLE,GA 30179
770.562-2850/Fax 770-562.2264
O 2014 Janus International Corporation AA Rights Reserved
CERTIFIED WIND LOAD RATED
26 GA SERIES 3100 DOOR ASSEMBLY
MAX. SIZE 16'-0' X 20'-W
e = T1004 "E
NONE I 1 --.. 2 _. 2