Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 8 Block 5 Waterstone 1780 AGR Builder Name: ADAMS HOMES Street: 5329 San Benedetto Place Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1512.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1244.60 ft2 b. Frame - Wood, Adjacent R=13.0 268.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1897.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1780.00 ft2 6. Conditioned floor area above grade (ft2) 1780 b. Knee Wall (Vented) R=19.0 117.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(177.0 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 356 a. U-Factor: Dbl, U=0.33 64.75 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.30 48.56 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.33 45.94 ft2 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 17.78 ft2 a. Electric Heat Pump 28.2 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 3.355 ft. Area Weighted Average SHGC: 0.272 14. Hot water systems 8. Floor Types (1780.0 sgInsulation Area a. Electric Cap: 40 gallonsft.) a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 56.34 Glass/Floor Area: 0.099 PASS Total Baseline Loads: 56.56 I hereby certify that the plans an e : ' tions covered by of the plans and ST,g this calculation are in complia e ' e Florida E y''�~ specifications covered by this �1,tfrtE Code. � calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed r DATE: a�-17-�o�n Winn KPomany this building will be inspected for compliance with Section 553.908 d C7 "t y *: ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OptZ� WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house. FILF COPY 9/17/2020 4:45 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 8 Block 5 Waterstone 178 Bedrooms: 3 User Conditioned Area: 1780 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 8 Block/Subdivision: Waterstone PlatBook: Street: 5329 San Benedetto PI County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1780 15664 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1780 15664 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0 1780 ft' ---- 0.38 0 0.62 ROOF # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1991 ftz 446 ftz Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1780 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 1780 ft' 0.11 Wood 117 ft2 0.11 Wood 9/17/2020 4:45 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS a Ornt Adjacent Space Cavity Width To Wall TypeEt In Et Height In Area Sheathing Framing Solar Below R-NIalile Fraction Ahqor C, 1 NW Exterior Concrete Block - Int Insul Main 4.1 40 0 8 0 320.0 ft2 0 0 0.6 0 2 NE Exterior Concrete Block - Int Insul Main 4.1 40 6 8 0 324.0 ft2 0 0 0.6 0 3 E Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ft2 0 0 0.6 0 4 SE Exterior Concrete Block - Int Insul Main 4.1 11 9 9 6 111.6 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ft2 0 0 0.6 0 6 SW Exterior Concrete Block - Int Insul Main 4.1 54 0 8 0 432.0 ft2 0 0 0.6 0 7 - Garage Frame - Wood Main 13 33 6 8 0 268.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Insulated Main None .25 3 6 8 20 ft2 2 Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 12 ft 0 in 0 ft 10 in None None 2 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 NE 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 4 E 3 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ft2 5 ft 6 in 0 ft 10 in Drapes/blinds Exterior 5 5 SE 4 Vinyl Low-E Double Yes 0.33 0.21 N 23.2 ft2 4 ft 6 in 0 ft 10 in Drapes/blinds Exterior 5 6 S 5 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ft2 5 ft 6 in 0 ft 10 in Drapes/blinds Exterior 5 7 SW 6 Vinyl Low-E Double Yes 0.3 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 391 ft2 391 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1827.5 100.33 188.68 .1409 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing[ HSPF:8.5 28.2 kBtu/hr 1 sys#1 9/17/2020 4:45 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 .28.4 kBtu/hr 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage. Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS ---- Supply --- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area -Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 356 ft' Main 89 ftZ Proposed Qn Main --- cfm 124.6 cfm 0.07 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan H Feb HeatinHJan Feb Mar Mar HX Apr APr I Jul May r j Jun Jul Ma X Jun ri Au ri Aug Se SeP Oct Oct Nov Nov HX Dec Dec H Ventin Jan Feb Mar [X] Apr May Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 9/17/2020 4:45 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 100 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.4 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1780 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.344 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.272 14. Heating system: Capacity 28.2 c) Area 7c. 177.0 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:. Date: Address of New Home: 5329 San Benedetto Place City/FL Zip: Fort Pierce, FL 34951 9/17/2020 4:45:59 PM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1