HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4
PublicationsContact Us 1 BCIS Site Ma Links% Search +
i 5 rcha e 11 Stats&Facts u p .
BCIS Home^ La In User Registration � Hot Topks � Subm t u rg t � � •
t 9 9 i
Product Approval
Rota
,max r n USER:Public User
• Product Aooroval Menu>Product or Aoulication Search>Aoolication List>Application Detail REVIEWED
FOR
FL# FLvision R7 CODE COMPLIANCE
• Application Type Revision
Code Version 2020 LlJC1
Application Status Approved STa E COUNTY
BOCC
Comments
Archived
Product Manufacturer Plastpro Inc./Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLV&
LOS ANGELES,CA 9 4
(440)969-9773 Ext� M.
IOTORCoPY
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbidgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440)969-9773 Ext18
scotUohnson@plastproinc.com
Quality Assurance Representative Ron O'Connell
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440)969-9773 Ext 16
ronoconnell@plastpro.com
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
01 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report .
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2021
Validated By Ryan J. King,P.E.
J Validation Checklist-Hardcopy Received
Certificate of Independence FL15210 R7 COI fbl Certificate of Independence.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1929 1996
ASTM D2843 1999
ASTM D635 1998
ASTM D638 2003
ASTM E1300 2004
ASTM E84 2005
ASTM G26 1995
G 155 2005
TAS 201,202,203 1994
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZl Q... 1/15/2021
Florida Building Code Online Page 2 of 4
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL15210 R7 Etc uiv of Standards(c)-off
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 07/21/2020
Date Validated 07/30/2020
Date Pending FBC Approval 08/05/2020
Date Approved 10/13/2020
Summary of Products
FL# Model,Number or Name Description
15210.1 a.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door-
Grain/Rustic/Mahogany Series O Inswing/Outswing(X-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes .FL15210 R7 II (c)Inst 15210.1.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.1 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.1.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.2 b.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door with Sidelite or
Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing(OX or XO;OXO-
Fiberglass Door Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.2.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.2 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.2.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.3 c.Smooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Double Door with or without
Grain/Rustic/Mahogany Series_ O Sidelites-Inswing/Outswing(XX;OXXO-Configurations)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL1521.0 R7 11 (c)Inst 15210.3.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.3 for Design Pressure Ratings,any F1L15210 R7 AE (_c].Eva(_15210.3.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.4 d.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door-
Grain/Rustic/Mahogany Series O Inswing/Outswing(X-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.4.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.4 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.4.ndf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.5 e.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door with Sidelite or
Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing(OX or XO;OXO-
Fiberglass Door Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.5.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 1/15/2021
Florida Building,Code Online Page 3 of 4
Other:See INST 15210.5 for Design Pressure Ratings,any I FL15210 R7 AE (c)Eval 15210.5.Ddf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.6 f.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Double Door with or without
Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing(XX;OXXO-Configurations)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 1S210.6.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.6 for Design Pressure Ratings,any FL1521.0 R7 AE (c)Eval 1.5210.6.1)df
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.7 g.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door-Outswing(X-
Grain/Rustic/Mahogany Series 0 Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 11 (c)Inst 15210.7.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.7 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.7.Ddf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.8 h.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door with Sidelite or
Grain/Rustic/Mahogany Series O Sidelites-Outswing(OX or XO;OXO-Configurations)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.8.0f
Approved for use outside HVHZ:Yes Verified By:.Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.8 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.8.0f
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.9 i.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Double Door with or without
Grain/Rustic/Mahogany Series O Sidelites-Outswing(XX;OXXO-Configurations)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL1.527;p R7 tI c lnst]_527.0.9.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.9 for Design Pressure Ratings,any FL15210 R`/ AE (c)Eval_15210.9.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.10 j.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door-Outswing(X-
Grain/Rustic/Mahogany Series O Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 11 (c)Inst 1 5210.10.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.10 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.10.1)df
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.11 k.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Sidelite or
Grain/Rustic/Mahogany Series O Sidelites-Outswing(OX or XO;OXO-Configurations)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.11.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.11 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.11.Ddf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.12 I.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with or without
Grain/Rustic/Mahogany Series O Sidelites-Outswing(XX;OXXO-Configurations)
Fiberglass Door
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZl Q... 1/15/2021
Florida Building Code Online Page 4 of 4
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.12.Ddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.12 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.12.Ddf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.13 m.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Surface
Grain/Rustic/Mahogany Series 0 Bolts-Outswing(X-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15210 R7 II (c)Inst 15210.13.odf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.13 for Design Pressure Ratings,any FL15210 R7 AE (c)Eval 15210.13.odf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.14 n.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with Surface
Grain/Rustic/Mahogany Series O Bolts on Active Door panel-Outswing(XX-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLIS210 R7 II (c)Inst 15210.14.2df
Approved for use outside HVHZ;Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.14 for Design Pressure Ratings,any FL15210 R7 AE (cC)Eval 15210.14.1)df
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15210.15 o.Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door utilizing the
Grain/Rustic/Mahogany Series O WINDSERTr"an operational window insert-Outswing(X-
Fiberglass Door Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL1;210 R7 II jc Inst 1.5210,iS.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15210.15 for Design Pressure Ratings,any FL1521.t)..f37__�E_.�c)_ val_15210.15.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
Bacic Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer,Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.•Pursuant to Section 455.27S
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ1 Q... 1/15/2021
PO t n+
R W R W Building Consultants,. Inc.
BConsulting and Engineering Services for the Building Industry
C P.O.Box 230 Valrico,FL 33595 Phone 813.659.0197
Florida Board of Professional Engineers Registry License No.9813
Product /n Report Repoallo.:
Product Sub Category Manufacturer Product Name
Category
Plastpro,Inc. Smooth L Wood Grain I White Wood Grain'
Exterior Swinging 5200 W.Century Blvd. Rustic I Mahogany
Doors Exterior Door
Assemblies Los Angeles,CA. 90045 Series O Fiberglass Door
Phone 440.969.9773 Inswing/Outswing-"Impact"
Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt, P.E. (System ID#1998)for
Plastpro Inc., based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of
Business&Professional Regulation.
RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and is in compliance with the 7th Edition(2020) Florida Building Code structural requirements
including the"High Velocity Hurricane Zone".
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact
resistant covering.
4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&
R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as
defined in ASTM E 1996 and FBC Sections 1609.1.2.2&13301.2.1.2.1.
5. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
6. Site conditions that deviate from the details of drawing FL-15210.4 require further engineering analysis by a licensed engineer or
registered architect.
7. Outswing configurations meet water infiltration requirements for"HVHZ". All other configurations do not meet the water infiltration
requirements for the"HVHZ"and must be installed only-in non-habitable areas or at habitable locations protected by an overhang or
canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees.
8. See drawing FL-15210.4 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Signed by
TEL 01390365 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,Inc. Lyndon F.Schmidt,P.E.
TEL 01391846 TAS 201-94,202-94&TAS 203-94 Testing Evaluation Lab.,Inc. William Shelton,P.E.
ETC-05-255-16776.0 ASTM D 635-98,638-03,1929-96&2843-99 ETC Laboratories Joseph L.Doldan,P.E.
ASTM G 26-95
ETC-06-255-17412.0 ASTM E 84-05 ETC Laboratories Joseph L.Doldan,P.E.
ETC-07-209-19303.0 ASTM D 635-98,638-03,1929-96&2843-99 ETC Laboratories Ben Meunier
2. Miami-Dade.NOA Materials
17-0712.05 Saflex PVB Interlayer(Eastman Chemical Company)
17-1026.08 Royal Mouldings(Ext.PVC)
No. Prepared by
inne
&Seale
by
3. No.FL Drawing 15210.4 RW Building Consultants,Inc.(#9813) ���e0a�S `-'�' 1����'9A Synd nF F.Schmidtt,,P.E.
°° �o°^GErJS: °o
4. Calculations Prepared by o� 4 �� C°"-," o® Signed&Sealed by
Anchoring RW Building Consultants,Inc.(#9813) o Ids 43�€OM, ;° ® Lyndon F.Schmidt,P.E.
ASTM E 1300 Glass Load Lyndon F.Schmidt,P.E. °
°
5. Quality AssuranceCIV
C�.
.P .
% Lyndon F.Schmidt,P.E.
��'a9 v �s Ii zt� FL PE No.43409
MR plastpro
5200 W. CENTURY BLVD.
LOS ANGELES, CA 90045
0 37.50"MAX.OVERALL
Smooth / Wood Grain / White Wood Grain FRAME WIDTH
Rustic /Mahogany
N Series O Fiberglass Door
INSWING / OUTSWING
"IMPACT"
GENERAL NOTES 0 _z
J Z
1. This product has been evaluated and is in compliance with the 7th Edition(2020)Florida Building z _
Code (FBC)structural requirements including the"High Velocity Hurricane Zone'(HVHZ). O
'-
x. _
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base W 0 ®/
material shall be beyond wall dressing or stucco. _ _
LU
w
3. When used in the"HVHT'this product complies with Section 1626 of the Florida Building Code and <
does not require an impact resistant covering.
oad
4. When used in areas outside of the"HVHT'requiring wind borne debris protection,this product > >
e complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering. 0 O
This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and FBC N M
Sections 1609.1.2.2&R301.2.1.2.1. aO 0
N5. For 2x stud construction,anchoring of these units shall be the same as that shown for 2x buck masonry
construction.
0
6. Site conditions that deviate from the details of this drawing require further engineering analysis by a
LL licensed engineer or registered architect.
0 7. Outswing configurations meet water infiltration requirements for"HVHT'. All other configurations do
not meet the water infiltration requirements for the"HVHT"and must be installed only in non-habitable
areas or at habitable locations protected by an overhang or canopy such that the angle between
o the edge of canopy or overhang to sill is less than 45 degrees.
s TABLE OF CONTENTS
SHEET# DESCRIPTION SHEET# DESCRIPTION
z1 Typical Elevations,Design Pressures&General Notes 8 Horizontal&Vertical Cross Sections(Direct to Masonry) MAX DESIGN PRESSURE(PSF]
2 Door Panel Details 9 3-point lock details CONFIGURATION FRAME
3 Lite frame details and glazing details 10 3-point lock details DIMENSION POSITIVE NEGATIVE
4 Horizontal&Vertical Cross Sections(2X Buck) 11 Buck and frame anchoring X 37.5"x 82.0" +75.Q -75.Q
0 5 Horizontal&Vertical Cross Sections(1X Buck) 12 Components
6 Horizontal&Vertical Cross Sections(Direct to Masonry) 13 Bill of materials See sheets 2&4 for hardware and lite frame design pressure limitations
7 Vertical Cross Sections(Thresholds)
cc
0.7' G1 G2 2.8"
TOP RAIL
0.41, —7EXTERIOR 0A, (COMP.)
•d•: a. .e :. IF
•� �V:
ED
•. .�,. .. tea. °� •• ,. �♦ .+ e . _♦ � ///
INTERIOR
C ,d
CAP(PVCJ AP(PVC)LATCH STILE(LVI:)
3 HINGE STILE(LVLJ _a�•
1 HORIZONTAL CROSS SECTION a '
2 d' •o •d
N
N
J
N . •�.
N
O j
N � •
J ....................................................................................................................................... .....................................
35.75 DOOR
......HAR
3 WIDTH ;:..::; MA]G DESfGN.;;'
o MANUFAG7URER MODEL
.......: ..:... . ..: .... ...... . PRESSORE.' S .
v 2 KWIKSET KNOB: SIGNATURE SERIES +75 G1
2 DEADBOLT: SIGNATURE SERIES(980) G2
KNOB: "F'SERIES(FS1) 75
SCHLAGE DEADBOLL "B"SERIES(860/62) ±
v
C / PAMEX LEVER: FL3B SERIES {75 INTERIOR EXTERIOR
sz DEADBOLT: FD7 SERIES
E / o.OL)
HOPPE MULTIPOINT LOCK: HLS90DO 3-POINT TONGUE +50
o, F
LL C7 ENDURA MULTIPOINT LOCK: TRILENNIUM 30W(3-PT) }75
Lu
Q 2 X -
N O See sheets 6 and 7 for multipoint lock details. .3
SEE HARDWARE
o TABLE FIBERGLASS SKIN
a h (0.126'MIN.THK.)
a /
FOAM CORE
2 (POLYURETHANE-
/ SEE HARDWARE 1.9 PCF MIN.) •a
v TABLE
Z :r
z BOTTOM RAIL
D (COMP.)
a
V
a
DOOR PANEL 2 VERTICAL CROSS SECTION
`o.
2
a
c
w
u
24.22'MAX. ���•
FRAME WIDTH 5/8"GLASS BITE
20'59 MAX' STRUCTURAL SILICINE(DOW 995)
D.L.O.WIDTH I A3
EXT. �N:
1"OVERALL GLASS THK.
U 1/8"ANNEALED GLASS Ei"
N1.860.090"SAFLEOPVB
INTERLAYER
_ 1/8 ANNEALED GLASS
= W 5 AIR SPACE h�
Lu = 1/8"TEMPERED GLASS
O (TYP•) EXT FRAME INT FRAME
s o ALUMINUM SPACER A3 A4
q 40 NON STRUCTURAL SEALANT
� A4 #7-19 X 1-3/4"PPH SELF-DRILLING SMS
INT.
c, 104
0 Gl GLAZING DETAIL
S .d ^a
% ° ui
e,
A—j
0
N `
FRAMI
4.26' I �=:DE IGN`>:=t
f i1kfAX...::..........:.
MANUFACTURER : ,..•: .
v �P•1 .,:,:-:::.-::��:::;•::::-:�::..:�::•:a;P.RESSURE S.
ODL LITE FRAME ppL ±75
0 24"MAX.
FRAME WIDTH RSL }SO
E 20.75"MAX.
D.L.O.WIDTH
m
a
a
N
= EXT.
_ `14 O 1/2"GLASS BITE,
A5
1-1/4"OVERALL THK.GLASS STRUCTURAL SILICINE(DOW 995)
1/8"ANNEALED GLASS
W
a w
a = 0.090"SAFLX®PVB
6 ITERLAYERQ 1.59"
o LL (nP') 1/8"ANNEALED GLASS
p 1.06"
o E. AIR SPACE - JLI
1/8"TEMPERED GLASS
z 1/2"NON-GROOVESWIGGLE
a `" W/DELCHEM#80 POLYSULFIDE A7 40 l g
1/8"BACKFILL A6
#10 X 1-3/4"PPH WOOD SCREW
o INT. G2 GLAZING DETAIL A5 EXT FRAME A6 INf FRAME A7 SCREW C
A
RSL LITE FRAME
v
R:\Clients\Plastpro,Inc PERMANENI\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-impact Opaque and Glazed\C-Drawings\FL-15210(2020)\FL-15210.1-G.dwg,4.4
�z
M
A
OOC
N
to O
0
0
7.� 00 W CD—• p..a IA ' p
N,y
Q Q
—0 o
Z ut v o
v to CO
Ja N M
� � W,{a t�N O•N �7t N A N
C V M 71 OD l
l=O Q � CIO O�
2
a V
n
cfl y n
Z
D ,
°
°q D D°
D. v.
m
Fp
D
D
a.. .D
A W 110
A
0< ;0
rri
D
D
a � D
7 y c
.rrnn
Q V a
O Z —4 o a.
� v
OD
A
a
..a
' D
D
d
0.151C-SINK ........... 4�
(n,P)
�i
Q
d�
3
v
0
N
N
J
s A
N E C E
2 1 C
J
o °v vo
c o °
o ° 1
E
0 .7 7
INTERIOR 40 >
o G _
z
a
E - -
A c W
LL 40
= vo °v
o T1
EXTERIOR °
11 1 2
N 7
27 G
1-1/4"MIN. 9 40 EXTERIOR INTERIOR
EMB.(TYP.) 1-114"MIN.
EMB.(TYP.)
a
a
a
1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTION
a Shown w/1 X sub-buck $ Shown w/I X sub-buck $ Shown w/IX sub-buck
$ Outswing shown(Inswing similar) Outswing shown(Inswing similar) Outswing shown(Inswing similar)
a
z
z
a
a
V '•
G
O
!1.
A
2
C
W
V
moo`
N)i
.,
JIi
`t
d+
3 '
v
e
0
N
N
J
O
N N E-
E
0
N 2
C C
ME
D 1 2 D D
U
w
v
c e
° .o E
CT M e 40 T �°INTERIOR
CL
E < .
v C
m v v
rn
� a
N v •
11 EXTERIOR 7
1(f °
11 9 40 27 M EXTERIOR INTERIOR
i
0 1-114'MIN.
a EMB. EMB.INP•I
0
1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3�VER77CAL CROSS SECTION
6 Shown Direct to Masonry 6 Shown Direct to Masonry b Shown Direct to Masonry
Outswing shown(Inswing similar) Outswing shown[Inswing similar) Outswing shown(Inswing similar)
a '
z
z
a
ii
c
0
o`.
A
d
N
Y
lJ
R:\Clients\Plastpro,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-DrawingsNFL-15210(2020AFL-15210.1-6.dwg,TA
° rn
rn
C-4 M
°. v O
O<
=3
v
O
o° A
° g O
M
v ° W
o� N
° W
° 41
°
°
° V
m
0
o
• e oo
rn
rn
O
e ;0
<
f y e
ga >
1
D n
� c n
y ..
70
rD 0 a
R7
O 0 e �
rnM
j
rn
EMB.PP.)
n
o.
C-4
4
p •n
O '
w 4
M
� � A
0 n p
n o
o p
O y
Q �
Z
a.
0 _
Z
M
> � � `,11111111/1/��
ww � (A 0 sCH
0% ``�.�`�: lyjO�''�.
z i.5' z a
MAX. t✓ MAX
125' m :
E ^$w MIN. E
. ' -w MIN. 1 +t�1
X. N
MA
P
C
C
40 40 D.
N
J
O "
N _ _
N EXTERIOR INTERIOR EXTERIOR INTERIOR
0
N
vl
VERTICAL CROSS SECTION 6 VERTICAL CROSS SECTION
8 Shown Direct to Masonry g Shown Direct to Masonry
`
OutsMng only w/4-9/16'jamb OuNwhg only w/6-9/16'jamb
o ,
V
w
N
N
C
W
Q
d
x �
E
A I
N cti+ INTERIOR
-
N
t2 I1 INTERIOR
D
i
N 40 40 N
CL M
LLA M � M
1-1/4"MIN. `4
0
EMB.(TYP.)
a E ° EXTERIOR E c is ° c
r'
W EXTERIOR
z �1-1/4"MIN. 1-1/4"MIN.--4 IIA 1-1/4"he
EMB.(TYP.) EMB,(TYP.) EMB.(P
3 HORIZONTAL CROSS SECTION 4 HORIZONTAL CROSS A
1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION - g Shown Direct to Masonry 8 Shown Direct to Masonry
a1.
$ Shown Direct to Masonry g Shown Direct to Mason Outswin o
a
Outswing only w/4-9/16'jamb Outswirig only w/4 9/16�jamb Outswing only w/6-9/16'jamb g only w/6 9/16'jar
N
Al
u
R.\Clients\Plastpro,Inc PERMANENT\A-Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C- Drawings\FL-15210(2020)\FL-15210.1.6.dwg,9A
D
Z
c
rD— OVERALL HEIGHT
ti HANDLE HEIGHT
M
0 ° e
C)
0 O
M
D
M 10.04"
N
y
T,0
�V
MY
OHO $0
¢2j o
m o�
s 0 v
�O
� o
°n �.
d
N
w
� s -
n
mx
z 8.87'
CD
to
b
v _
'a
s
PU x � is „;SO2
08 c c C) c c O(� m m
�O .gip x n
�O
to a
3.61., w I�-16'
43.09" �•� F s....Mfzj)
i
55
3
o •
N
LL
� N
ry '
O
N
J d
N
C C7
3 C14
1O o
� O
s
N
0
10
N Q '
Q
0
C
d ®a
E
I
d Cl!
^' 0 57 w
b0
N
62
0
CL
9 MUCK 58
0
a IX BUCK G
43
0
0 DIRECTTO M
a
MASONRY
z -
z
s
a
V
o ENDURA TRILENNIUM 3000 STRIKE JAMB DETAIL
a 3 pt.Lock
R
a
d
z
4-9/16'JAMBT4-9/16"JAMB F DIRECT TO MASONRY JAMB(TYP.)
4,. (SEE SHEET 8)
(TYP.)
e °'. . °' V
41
;7
a
I4 ,Y.
SEE HINGE L 2X BUCK o
3 D TYP..HH B D DETAIL(TYP.)
G IX BUCK
DIRECT TO o
N MASONRY7 MASONRY D MASONRY ?;
t2 OPENING M OPENING TYP.HEAD
s
&JAMBS
N
O
N_
FRAME
_
U
3 2X BUCK 4-9/16"JAMB M v O c
o
V ^0 2X BUCK �6-9/16"JAMB N
s b DIRECT TO
MASONRY
JAMB(TYP.)
(SEE SHEET 8)
CL
'a ADA SILL
E a ( ONLY
• a
2' a
`m
x
7.
BUCKANCHORING STRIKE JAMB FRAMEANCHOR►NG HINGEJAMB
Masonry construction
21
CONCRETE ANCHOR NCHOR NOTES: DIRECT TO
a 1.Concrete anchor locations at the comers may be adjusted to maintain the min. DIRECT TO
a DIRECT MASONRY M
edge distance to mortorjoints. MASONRY M
"MAX Z Concrete anchor locations noted as ON CENTER"must be adjusted to M MASONRRYY
o maintain the min.edge distance to mortarjoints,additional concrete anchors 28 1 X BUCK G
a may be required to ensure the'MAXONCENTER"dimension are not exceeded. G 1XBUCK 9 1XBUCK G
v 3. Concrete anchor table: 2X BUCK L
`o MIN CLEARANCE MIN CLEARANCE 2X BUCK 58 58 2X BUCK 2X BUCK L
ANGN9R ANCHOR M1N TO MASONRY TO ADJACENT< 11
TYPE S1ZE EMBEDMENT
:..:.....EDGE: ..:... .ANCHOR...` 1X BUCK 11 DIRECT TO
z ITW v 11
z TAPCON 1/4" 1.1/4" �" DIRECT TO 11 ❑ M MASONRY 11
w ELCO
ULTRACON® t-1/4" t^ 4" MASONRY G 1X BUCK
a
S 1TW ® 3/16" 1-1/4" AS SHOWN 1.1/7 27 58 2X BUCK
0
TAPCON
Q 1,WOOD SCREW INSTALLATION NOTES: LATCH&DEADBOLT DETAIL HINGE DETAIL HINGE DETAIL
Maintain o minimum 5/8"edge distance,I"end distance,&1"o.c.spacing of
Inswing OUtswing
wood screws to prevent the sprfing of wood.
c
m
u
4.56" 4.6" 7 ��4.56"� o �U
N �
I ---2.44' 2.131,
N
3 SO OUTSWING THRESHOLD T, OUTSWING THRESHOLDr,-'%POLY FIBER JAMB
DLP(QOSR) Columbia High Dom(581) plgo
o -
N
i N
4.68" (� 4.56" ►I
a 47
LL
— II ----
zv F�-----2.36" 2.7'
o
�ZOUTSWING THRESHOLD OUTSWING THRESHOLD
DLP(Q05H) J Columbia(575) Z WOOD JAMB
t�
v
a
c 'v,
L rn
a
0.52, (�I—
N OLRSWING THRESHOLD WSWING THRESHOLD WEATHERSTRIP �n1 DOOR BOTTOM SWEEP
Endura(Z-Series) 38 Columbia Endura Force 5
0
a
0 5.625„ 4.56"� -
a
v
•``o ® �4.56'
ti
z
z l
a
tt
36 INSWING THRESHOLD 37 INSWING THRESHOLD 29 ADA THRESHOLD
0
Endura(Neries) DLP(ISCS) DLP
m
`a
c
a
V'
K
BILL OF MATERIALS
REM# DESCRIPTION MATERIAL V;
A 1 X BUCK SG>=0.55 WOOD
B 2X BUCK SG>=0.55 WOOD
C 1/4'MAX.SHIM SPACE
D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL
E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE
^ M C90
301 OR HOLLOW BLOCK CONFORMING TO AST
G 3/16'x 3-1/4'PFH ITW CONCRETE SCREW STEEL
° I 1 X X 1-3/4'PFH'ELCO OR ITW CONCRETE SCREW STEEL
N J 1/4"X 3-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL
K 1/4'X 2-1/4'TTW CONCRETE SCREW STEEL
L #10 X 2-1/2"PFH WOOD SCREW(1.1S MIN.EMBEDMENT) STEEL
N M 3/16'X 2-1/4'ITW CONCRETE SCREW STEEL
N N 3/16'X 2-3/4'ITW CONCRETE SCREW STEEL
P 11 X X 2-1/4'PFH ELCO CONCRETE SCREW STEEL
1 POLY FIBER JAMB COMP./VINYL
3 2 FINGER JOINTED PINE FRAME WOOD
0 7 WEATHERSTRIP FOAM
8 DOOR BOTTOM SWEEP VINYL
9 4'X 4'BUTT HINGE STEEL
11 #9 X 3/4"PFH WOOD SCREW STEEL
v
22 3 POINT"TONGUE"MULTIPOINT LOCKSET(Mfg.BY HOPPE) STEEL
23 MULTIPOINT STRIKE PLATE(TONGUE SYSTEM) STEEL
0 25 LATCH AND DEADBOLT STRIKE PLATE(TONGUE SYSTEM) STEEL
27 LATCH STRIKE PLATE STEEL
E 28 DEADBOLT STRIKE PLATE(SECURITY) STEEL
29 ADA THRESHOLD ALUM
30 OUTSWING THRESHOLD ALUM/WOOD
N 31 OUTSWING THRESHOLD ALUM/WOOD
> 32 OUTSWING THRESHOLD ALUM/WOOD
0 33 OUTSWING THRESHOLD ALUM/COMP
34 OUTSWING THRESHOLD ALUM/WOOD
36 INSWING THRESHOLD ALUM/COMP
37 INSWING THRESHOLD ALUM/WOOD
38 INSWING THRESHOLD ALUM/COMP
40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS -
g' 55 #10 X 1-1/2"PFH SCREW STEEL
57 BACKING PLATE STEEL
58 #8 X 7'PFH WS STEEL
60 MULTIPOINT STRIKE PLATE STEEL
z
62 ENDURA TRILENNIUM 3000 LOCK ASSEMBLY STEEL
z
w
a
V
C
O
a
m
a
c
v
U