Loading...
HomeMy WebLinkAboutConstruction PlansProvowide new frame waif behind vanity for recess MD cabinets Contractor to remove exi tub and surround for new cap existing plumbing as n, Replace existing bathroom endows with new PGT single Hung windows in existing opening. Windows to withstand pressures stated in permit info. box on this sheet for zone S. Exterior face of wall \ existing � '� WALL TV kEnAIN Attach window to block wall with 3/16" dia. x 3" tap -cons with min. 1 1/2" penetration at 12" o.c. max and 6" o.c. max from each corner thru 1" x 4" PT Buck P.T. Buck 7 airl�a f hP;grlpr NTS FL.00�', i'L,4N with n&w electric in existing openings - winnows to withstand pressures stated in permit info box on this sheet for zone 4 TYPICAL NOTES: SCALE 1/4" I. Contractor to verify ALL notes and dimensions prior to proceeding with work. 2. Contractor to STRICTLY enforce ALL OSHA Requirements. 3. ALL Lumber to be used as Beam, Rafters, etc... to have a minimum 1,400 F.S.I. fiber stress. 4. No dissimilar metals to touch. 5. ALL wood in contact with concrete shall be pressure treated.' 6. ALL wall dimensions are nominal and not finished wall or stud dimensions. 1. ALL plumbing fixtures to be low flow. Exterior face of wall—\ Detail FILE Product Approval Submittal Affidavit Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights Opening p g NOA FL Product Model # Manufacturer Glass Attachment method TEST Expiration Design Pressure g of Approved Tests Type NUMBER Date (. 0�1-0322,06 Single Hung Series SH-100 PGT 5/16° 1/4" dia. x 3" Tapcons w/ min. I I/2" penetration at 3-23-II + 70 psf Impact Type A 12" o.c. max and 6" o.c. max from each corner thru PT Buck 2. 08-1112.IQ Picture Window Series PW-701 PGT -1/1(." 11 1/4" dia. x 3" Tapcons w/ min. 1 1/2" penetration at -1� + 7O psf Impact Type A 12" o.c. max and 6" o.c. max from each corner thru PT Buck 08-1112.10 Picture Window Series PW-701 PGT VI „Air 1/4" dia. x 3" Tapcons w/ min. 1 I/2" penetration at 2-19-14 + 70 psf 3. Impact Type 12" o.c, max and 6" o.c. max from each corner thru PT Buck 4. FL %40.4 Fiberglass Door Fiber Classic Thermatru 1/16' „A" 1/4" dia. x 3" Tapcons w/ min. 1 1/2" penetration at Impact Type 12" o.c. max and 6" o.c. max from each corner thru PT Buck Product NOA FL � Model # Manufacturer Attachment Method TEST Expiration Design Pressure g of Approved Tests NUMBER Date Connect Mull to Clips w/ 1*12 SMS screws staggered and Mullions I" x 2 3/4" x .315" PGT connect clips to Buck with 3/1C dia x 3" Tapcons with 6-28-11 ± 91.0 PSF 06-0125.0-1 min. 1 1/2" penetration thru PT Buck ALL Product Testing by: Miami -Dade County Building Code Compliance Office / Product Control Division I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record ) >xlsting entry doors with Therma Tru 3/4 lite over fiberglass door. Door to Zone 4 Pressures stated in o box n this sheet 6 existing side kites/with new npact, glass PGT '�H 100 window ndmg zone 4 pressures stated in info box on t6s sheet TING �R GARAGE Attach door to block wall with 3/16" dia. x 3" tap -cons with min. 1 1/2" penetration at 12" o.c. max and 6" o.c. max from each corner thru I" x 8" PT Buck ___<I"x8" P.T. Buck 2 sides 1 header �rfOr DOOrS NTS =lorida Building Code: 2001 Edition with 2009 Supplements and ASCE 105 Building [Design is: Enclosed Mean Roof Height: 20'-0" Roof Pitch: 6:12 nternal Pressure Coefficient: ±0.I8 psf llidth OF Roof End Zone: 4'-0„ Wind Speed; 140 mph 3 second gust hind Exposure Classification: -a-Adjustment factor for Exposure Height:.1.0 components t Cladding Wind Pressure Roof Zone: I. Existing psf Roof Zone: 2.Existing psf Roof Zone: 3Existing psf :omponents t, Cladding Wall End Zone Width:3'-0" :omponents t Cladding Wind Pressure Wall- Zone: 4. +35.3/-38:2 psf Wall Zone: S. +35.3/-41.2 psf Omponents t Cladding Wind Pressure on Garage Door: Existing psf Shear Walls Considered for Structure? Yes .ontmuous Load Path Provided? Yes Are Components an Cladding Details Provided? Yes 'linimum Soil Bearing Pressure:2,500 psi, Presumptive: Yes By Test: This Building Shall Approved Shutters: Impact Glass: X Both: Existing window to remain -, THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE Cools. Privacy wall shown as dashed for clarity FLAT ROOF TO L 12 PITCH GABLE ROOF LESS GABLE ROOF FRS THAN 2:12 PITCH 2:12 TO 12:12 PITC 0 = Roof Zone I iE = Roof Zone 2 = Corner Zc Wells Zane 4 Walls Zone 5 Roof Zone 3 Replace existing bathroom windows with new PGT Single Hung windows in existing opening. Windows to withstand pressures stated in permit info. box on this sheet for zone 5. Verify exact size in field prior to ordering PGT sH '100 Pro -View windows in existing openings - Windows to withstand pressures stated in permit box on this sheet for zone 4 Info R T( A L F O I `�I l T ELEVATION Replace existing entry doors with with new Therma Tru 3/4 lite over one panel fiberglass door. Door to withstand Zone 4 Pressures stated in permit info box on this sheet SCALE: 1/4" = I'-O" - Braden Braden A1,4, PA Remodel For: Architects - Planners 411 Coconut Avenue M I �^ r 5. y Tel : (112) 281-8258 Fax : (112) 281-8283 %= Stuart, PL 349% I*AAC000032 St Lucie County Florida Date Drawn Drawn By: Sheet 6-7-10 C.C.U. a m Revisions Checked By: D.R.B. OF 6-21-10 Product Approval Revision Comm It O-92