HomeMy WebLinkAboutREVISION1:12 MAX SLOPE MAX LENGTH RAMP SLOPE BETWEEN LANDINGS SCALE: 1/4" — T—O" Ham. O"__. ramp run landing " LANDING REQUIREMENTS CHANGE IN DIRECTION SCALE: NTS SCOPE OF WORK: TO CONSTRUCT NEW WOOD RAMP FASTENED TO THE EXISTING PORCH ST.I JAN 2 9 2018 I•— 32 —•� ry Gtu i 36" 35" 1 Grade RAMP SECTION VIEW SCALE:NTS a4Hd em"nave vd: Chsol Nl Ma 3ti(I x•ro2'm Imater. 314x6 nail _'2A rail IlandruiI I-1`2ii lw, % Irtkltl tit1f11tC4 ._,.„.,,. 2x4 we 1x1ard gr4\6 lk,t,ring 3.5 —J 2x6 stringer C:�_4x4 Ixtst POST DETAIL SCALE: NITS 1"x5—r PT WOOD DECK SPACE J" APART 2 #8 SCREWS PER JOIST MUST BEAR ON MIN. 3 JOISTS RUN PERPENDICULAR TO 2"x6" PT JOISTS JOISTS SPACED AT 16" O.C. r exterior sheathing existing stud wail — existing 2x band joist — or 1" minimum EWP rim joist 2" mina 1.518" min. 5" max. 2x floor joist, -- 41 2" min. wood I -joist, or MPCWT existing wall- 5' THESE PLANS AND ALL PROPOSED WCRii ARE SUBJECT TO ANY CORREC T ICNS REQUIRED BY FIELD INSPECTORS THAT 141-V BE NECESSARY IN ORD21"I TO C01"Vi LY WITH ALL APPLICABLE COTES. ST, LUCIE COUNTY BUILDING DIVISION REVIEWED BY_ DATE PLAN AND PEWIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE DESIGN PARAMETERS APPLICABLE CODES: 2014 FLORIDA BUILDING CODE, 5TH EDITION 2014 FLORIDA BUILDING CODE, 5TH EDITION (EXISTING BLDG.) BASIC WIND SPEED: 170 MPH (3-SECOND GUST) = 132 MPH (FASTEST MILE) EXPOSURE CATEGORY: B remove siding at ledger prior to installation threshold carefully flashed and caulked to prevent water intrusion ledger and joist flush on top continuous flashing extending past joist 311— hanger _, ,_--- deck joist 1f2" diameter lag screws or through -bolts with washers joist hanger 2x ledger board; must be greater than or equal to the depth of the 2"x10° deck joist and no greater than the LEDGER depth of the house band or rim joist LEDGER SECTION VIEW SCALE: NTS 14' c snigger Taman In 2 rows / 5 5"' min. for 2x8 ® ; 55" min. for 2x102.z10 i 7.5 min. mr2x12 lag screw. through -bolt, or T anchor with washer I 314' min. LEDGER CONNECTION SCALES NTS embed anchors —1 per manufacturer x recommendations I' i existing hollow ­0­' masonry wall i block cells tilled with grout or concrete at anchor locations (new construction) I I 8" block wait minimum to resist corrosion and decay. this area should be caulked t deck joist 1/2" diameter approved epoxy or adhesive anchors with washers �- joist hanger 2x ledger board; must be greater than or equal to the size Of the joist LEDGER SECTION VIEW MASONRY WALL SCALE: NTS posts must be centered on footing SIMPSON Pe about 1t=`— =:— 4 i •x, ".. �1I. a .. 17 min. r .a , I1 a 4 POST TO FOOTING SCALE: NTS USE STRONG BOLT WEDGE ANCHOR INTO EXISTING CONCRETE POST TO EXISTING CONCRETE SCALE: NTS Z 4i Z Lwl Q Q UJLU o r aR LJ o 5qy LU Z a5 N rW fir _ 0 > :E u a�eOPNER HgM�,00A ENS� . No 79154 �: llT$/*X2o18vv STATE OF r,O: ANip c� O R t.O s'0NA� `� `% If 6 It 52 R E V I S 1 0 N S N 2 a z n a z DRAWING TITLE: BUILDING DETAILS .lOH No: 2016 - Ramp DATE: 4/4/2017 DRAWN: T.H. CHECKED: T.II. Ll 4l r