HomeMy WebLinkAboutApprived PlanN
c
4=
N
8'X8' SUNDECK WITH 4
BUBBLERS AND
UMBRELLA SLEEVE
6 ft.
loft
111611 WALL
- HEIGHT%
-611
-611
-611
24"
THICKENED
FOOTER
24 ft.
3.5' DEEP
TILED BENCH
EDGE
58 ft. 1 in.
35 ft.
4.5' DEEP 5.5' DEEP
COLOR LED
..� lft6 1ft.6 \ f VAC L NE
3ft.0 n 5ft 4in
-6 -6' -6'
11'6" WALL
HEIGHT
TILED BENCH EDGE
0
6.5' DEEP 7.5' DEEP &' DEEP
O
(2) 2411 SHEER DESCENT
WATERFALLS
COLOR LED
5 ft. 4 in.
5ft 4in.
4=
m
ft 9 in.
O
x
7 ft. 2 in.
Jandy Pro Series VS FloPro Series Pump
VS-FHP2.0 Performance Curves
00
43
9D
39
80
35
° 70
30 0
6
a
LL60
28 �
v
E
50
22 c
N
60
17 m
� 30
p
13 a
20
9
10
4
0
0
IG
SP
ED
W
it
I m
500rp
2
L�W
m
S'�EED
0 10 20 3D 40 50 60 70 80 90 100 110 IM 130 IQ 150 160 170 180 190 200
FOOTER DETAIL.
(2) #5 REBAR
12" o O
12"
NO SCALE
24"
THICKENED
FOOTER,
FOOTER DETAIL.
2) #5 REI IAR
181,
12"
NO SCALE
' ncrune>i>e>eaeae>e>e>r>ciev>i>e>eae>.v. aewi_>e>.!>n
C
"LOCATION OF GFI
" RECEPTACLE
8ft. 4 in. 101 FASCIA TO BE DETERMINED IN \ ,
FIELD PER NEC 680 �U
HEIGHT
EQUIPMENT VERIFY
PAD EXACT L
LOCATION IN
PER FBC FIELD WITH CO
= R4501.22 SUPERVISOR W
m
O �/ DOOR AND WINDOW 0
X ALARMS BY OWNER ()
IQ
POOL BARRIER PER FRC R4501.17.1- '
R4501.17.3 AND ANSIINSPI-5-1995
SAFETY BARRIER PER FRC R4501.17.1- OWNER TO CLEAR
R4501.17.3 & ASTM5034-95, ASTM D3787- PATH IN GRASS. DO
19 ft. 5 in. 89, ASTM 653-96
NOT ACCESS OVER
DRIVEWAY WITH
HEAVY EQUIPMENT
I
I
I
I
I
PIPING SCHEMATIC MUST HOLD 35 PSI FOR AT NOTE: POOL PUMP MOTOR LOCATED ABOVE
-- LEAST 30 MIN. - GRADE. PROVIDE SEPARATE CIRCUIT FOR
(NO SCALE) ELECTRICAL _DIAGRAM AND GPI OUTLET PER 2011 NEC POOL PATIO
PUMP MOTOR(S)AND HEATER(S) ETC
(NO SCALE) WATER LEVEL
R -SSURE RAIN TIGHT OUTDOOR NOTE INSTALL 125V 15
FILTER GAUGE ELECTRICAL PANEL AMP WEATHERPROOF
(SIZEDPER LOAD) DUPLEX RECEPTACLE AT FROM
TO MAIN SERVICE PANEL IN LEAST 10 AWAY AND
APPROVED ONDUIT(SD:EO G'F'1 00 POWER
>REPER LOAD) OUTLET NOT MORE THAN 20' Z 1" LIGHT SUPPLY
TDOOR TIMEC cK FROM THE INSIDE WALL CONDUIT
WIRING TO POOL LIGHT IN OF THE POOL
APPROVED CONDUIT PUMP UNDERWATE UNDERWATEMoronLIGHTNOLIGHTDETAIL
UL APPROVED DECK BOX NICHENO SCALE)
FOR DIRECT CONNECTIO NOTES:
2)SEPARATO WET NICHE (1) POOL PANEL AND SWITCHES MUST eE AT APPROVED
RAINS 36'LEAST 5'FROM THE INSIDE WALL OF THE POOLGROUND CLAMP
IIIPART MUST I ELECTRICAL WIRING AND EQUPMENTCONTINUOUS BOND WIRE
�POOLL HT SWITCH' MUST INSTALLED IN ACCORDANCE WITH THEUNDERWATER \ EITHERINDOOROR 2008 EDITION OF THE NATIONAL ELECTRICAL
LIGxr OUTDOOR CODE COMMON TO POOL STEEL,
APPROVED WRONG IN 1" POOL FINISHRAILS & EQUIPMENT
SCH 40 PVC WI #8(3) PROVIDE PROPER WORKING CLEARANCE BONDING CONDUCTOR SPACES FOR ELECTRICAL EQUIPMENT AS PER
(COMPONENT OF PUMP) NO-26 OF NFPA 70
FOOTER DETAIL
2) #5 REI AR
G
12"
NO SCALE
THESE PLANS AND ALL PROPOSED WOW
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BB NECESSARY IN ORDER TO
COMPLY WRH ALL APPLICABLE CODES;
POOL RETURN LINES 2.5" TO FIRST TEE
POOL DETAIL
APPROVED MAIN DRAIN FRAMES AND
GRATES PER V.G.B. ASME/ANSI 112.19.8-2007
• APPROVED WITH THE 2014 FLORIDA BUILDING CODE FOR
° ° RESIDENTIAL WITH THE 2014 SUPPLEMENTS AND THE ANSI/
° APSP-7 2008 FOR SUCTION ENTRAPMENT AVOIDANCE
File Copy
.# n03-0454
ST. LU TF r0j- 'T'I' RT1II, nru.^ ^ry7SION
BFT iF1'LI E,}O. olvw LACE
itiLviDATE ;1;�T 5G�CM Dkll 1
PLANS ND PEILMI I MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE•
°
MINIMUM (2) SUCTION LINES PER PUMP 3_FT.
APPROVED WITH THE 2014 FLORIDA BUILDING CODE
SEPARATION OR SEPARATE PLANES
STH EDITION FOR RESIDENTIAL
°-
3 FT. MIN.
SPECIFICATIONS
•
MAX_. WIDTH 23' MAX. LENGTH 41'
•
MIN. DEPTH 3.5' MAX. DEPTH 8'
SHAPE CUST ELEVATION T.B.D
`I
FILL FROM EXCAVATION HAUL
3" SUCTION LINE TO
TILE - INTERIOR FINISH GEM FILTER CS200
PUMP MAX 181 G.P.M.
FPS 3" PLUMBING MAX
NG LINES
PUMP MAKE PER-FBC 450110 - S r\ C:,'r - --- -
TO FILTRATION PUMP
8 FPS M
FROM SUMP WI 3"
PUMP HP: POOL 2HP VS FLOPRO _ SPA NA
FILTRATION PUMP COMPLIANT WITH ANSIIAPSPIICC-15 2011
LIGHTS POOL 2CLR LED SPA NA
MI$C. NOTES
-- - --- -
TRNFORM: POOL 300 WATT SPA NA
1. ALL STEPS AND SWIMOUT BENCH
MAIN DRAIN: POOL 2 SPA NA _--
EDGES WILL HAVE 2X6 CAP TILE
- -
BORDER OF OPPOSITE COLOR OF GEM
SKIMMER (1) TIMER INCL
FINISH FOR VISIBILITY
2. HAND HOLD TO BE INSTALLED AT ARE
- - --- - --
RETURNS: POOL 3 SPA NA
WHERE DECK RAISED A6"
JETS: POOL 0 SPA NA
ABOVE POOL
_
VALVED VAC LINEINCLFILL LINE
#eGROUNDWIRE
DISCHARGE LINE TO GROUND
v
HANDRAIL BONDING DETAILCHLORINATOR
DANDY TRU CLEAR SALT
48" MAX
o
SZ I"FPS
WHERE APPLICABLE
PER NATIONAL ELECTRICAL CODE
ii
- --- - - -
HANDRAIL NA LADDER NA
WATER
DEPTH F,0- MIN.
--- - --
DIVING BOARD NA SLIDE NA
HEATER RHEEM16350 HEAT PUMP
TrE
1. TREAD IS MIN. OF IV WIDE.
VACUUM HEAD , INCL POLE INCL
12"
2. RISER NOT GREATER THAN 12" EXCEPT IF
VACUUM HOSE INCL -BRUSH
G MORE THAN (3) TREADS ARE USED.
_ _INCL-
3. ALL STEPS TO BE SOLID GUNITE 3000 PSI.
LEAF SKIMMER. INCL TEST KIT_ INCL
TREE I STUMP REMOVAL NA
REMOVE EXISITING CONCRETE NA
N.T.S.
PUMP POOL PATIO INCL
SCREEN ENCLOSURE BY PIONEER
_ 18" MIN.
ELECTRICAL INCL
(ENTIRE PERIMETER)
POOL PATIO CONCRETE FLOCRETE
PAVER DECK OR CONCRETE DECK
-_
EXISTING PATIO LEAVE EXISTING ALONE
DECK DRAIN INC
GALLON CAPACITY -POOL 32,400 GAL.
ND- FR.`\soaGALLON
CAPACITY -SPA NA
IE
--I
RATE 6 hrs
CH
OLd
eonuGEsouocoPPE_'TURN-OVER
WARE RTERMITE
-
TREAT INC BARRIER INC
_ '- -j-
MAX. WATER VELOCITY-8 tt/s FROM TRUNKLINES
NTIAL oNDIN� ORID DETAIL -,
TO 8 tt1S SUCTION.' ES _101ps MAX RETURN LINE
PER N.E.C.2011 SEC.680.26 MINIMUMI8" FROM EDGE OF POOL
SKIMMER MIN. "W 25 GPM
(WHERE ADOPTED) AROUND ENTIRE POOL PERIMETER
- BURIED a TO6-DEEP
SURFACE AREA OF POOL - 755SQ. FT 128LN FT
wM.r.A%IeaN�w6.wNe:v6ew"
640-18XXV
e"Ibi"ST"FIOMIn WFaeew
Wamm'"Ednavren Newmvr mRSDlest(nrcum T. di, MJYCI
Cmm 400n ;ul anv C)LWeaaMQNfietlaN Ud IP:n "Emm
ffa"
blM1evllkeMnOdMWA11E198MhW SMEAI.19MYN9 R0.+lbxd
Ty�C41aV�}
m GscxlwmNe ANm62M1. rmneetr.wim..na.latmloxnmc
HHEImpeAalHgMry sureld Btu.G9ffiIb]]9.
a" 1bkN:
WaNrvw a0abd
D IMIk � Blazk D Gry Q pakGry D lNS<
LIaG,10 O.k.O
awpm�bretrrieMeea"xWL"ayb�v tiau4
W wFlo-ipdavtrtlWnWFw "4Wnwnsgn bWntr"emvwvnYPRYMewwvwvwaW.
EAEGVHXOTF9:
+. EFEEEME POOL CW9]IVGTONTO N YWIRA. KOO.CO MDVHTHLLL LOLL OFDRMNCESAN0
mxINE REouLAno
2 SVE0041W POOL TO BEM M ROCIL OR UFKXWMReiO SANL 4L W ILLS AND FLOORS SXRLL BE GIMREp
OR PPIWFOWAIICECONCREn1YtlMMWN; F.&LCONCRFI81Q2S Wra1EOWRE¢NB 91R6NGl%
S ENOXEERBXRLL¢HpM®N'8gL8FINNOL68nUN 25W P.SF., ¢i MICK,EILTORLOD¢, BOPTSgL
ISFOWG.A801LBlAINNGCNPICm'OR 2,Ma P.9F.XM Bi¢!UB®W lNE ¢BNNI
0. RBIFOROMOBARSWPBBSOEBMET. EL A4L
E6AM LRFWOTOBEP.V.GBCIEg11p401L1MORDMKNXEH9.F.MMOVK.
N HOO.M O.BB¢E S¢LCCEVNINLO LO ORMHNICE&
]. GI9POE OFrod.WRIER BINLLCONFORMTO LOCµ ORpN4NCE&SUMACEMAWNGSXALL CIX(rNH
WATFXRWMPROPERIYLI¢9PoMdOB N]TPBI818F FORM WCN COIpUR.
L NEM MIPPLYBMPLY RLM4LLLRE NSFRL®SO n1ATMFR@BIp CROfiSEOH1ECl10NltlniA
ODMl6IICWAI®IBUPPLYORYG1THt Gll081LL 8Y41FM
a aMIEATM.VlMNES SHWU1 HAAFIR:AREAOF 4%TNE VEA OFEEUMFREEAWE
MR SU 611M 61RIFSlBMULL NMEAMNOVAM.F M.YiEM! WIA NW.N1M FREE AWE OF9%n1E MFACi
I¢6uEnoxLeL.
++. ELECIxICAL:IxsrALL wMv+o s pEV Icle M fixdvx d vooL oArl• xm6oM uaxr cowFrnpx TO
CONFgfX TO XATN)XAL MFEIRIEµ EOm LAIEBT 1pmON.
12. ALL MErµ11C CO W YIR, RPNO 6YERlMa, RWI.ORfEp 8iE4 MOM FM W EB 8 FgU9N0, MRµ
PARrs of LAODBRx xAxprues, pnM4 wAlna a 6wroRrs To - Baxpfip roaRIBR a aMwpep TO A
COMMDx p1 W M. BdldM Cg011CTM 8 WLL XOT RE BMM.LMI TNM iB COPFB0.
18.INe OVEMMMOPM WIff OVERPoOL WAll0.
10. CMRRMIOEfLTBISMKLIMYEAPRIMTION WTF NOTN F%CFFOS 0.PM.IS.F.OI FLTM AMA HO
GCKYeA8X11EWR®.
1 S. CdfERACTp[ BN W L YHIBY µL pNW9M W N6 AND Cg101110N8IT M]G BEFORE SFMlllp THE pROIBtS.
14..PW KmEFm N SH L BE EARN
E FFERRCF.�YRF.BLCOMPMY.
ifi. BPECLLL ATIMIIIOM a1NLL ¢ ON1N TO E%IRIXO FCV NDATION TO PILE V MR MIpER¢XIENI.
JOB NAME:ALSDORF O.I KAX
A
__.""�® M� -.W. �•.W�-"w- DDRESS.11175 MUL ER RD. FT. PIERCE
v"Np1eVlXyanWYPR tr
�� OUTSIDE EMI""a" E' O PEPO E 34945
�v�mnmw.rvxarm.nms�mq�ea+am.auN9w.memmmM.-N„rnw�.nPxm-......lewrgaaoa. M.1.v��
�., _ 6 r. - _.
6' AND FURTHER 4" THICK WALLS WM3 REBAR @ 12" O.C. EACH WAY
9' TO 6' - S• THICK WALLS WM3 REBAR @ 12. O.C. EACH WAY
0' TO 3'- 8' THICK WALLS WM REBAR @ 12. O.C. EACH WAY
Cp I
< m m 3 ft.
0
J i j _', L
EXCAVATION INTO THE ANGLE OF REPB8E IS ALLOWABLE
PROVIDED:
' SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD
BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT
* NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES
• COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED
AT C.O. OF THE SWIMMING POOL
CONCRETE DECK
114" PER FT. SLOPE
NOTE: REMOVE GRATE 8
WELL POINT PLUG FROM MAIN
OVERPOUR
(OR CAP TIL"
BEND INTO D CK 48"
DRAIN S ATTACH AUX. PUMP
WHERE
LINE WHEN EMPTYING POOL
APPLICABLE
6"X6" TILE.
4" SLAB, }
INTERIOR
2500 FIBE
GRATE SHALL
FINISH
TYPICAL WALL
BE SECURED IN
4 112 TYP. SECTION
PLACE SO
WALL
WELL POINT
THAT TOOLS
ARE REQUIRED
(NO SCALE)
FOR RE AL
STEEL -TEN FORM
6" TYP•
R KRAFT WALL
FLOOR
#3 @ 12" O.C.B.W.
THREADE
NOTE: FOR DEPTHS
PLUG
REATER THAN V ADD 1-
#3 COVE BAR @ 6" O.C.
TO PUMP - 0
GRAVEL BED
PERMIT NO.:
DATE DRAWN:MARCH 3RD 2017
DRAWN BY: BOBBY AUSTIN
DESIGNER APPROVAL:
CUSTOMER APPROVAL:
SCALE: 1/4" = 1' RAY REINHARD
PE # 47041
1010 Easter Lilly Lane
Unit 203
fi
Vero Beach, FL 32963
1 ROW OF WATERLINE
3.5'
1' R
#3 STEEL 12"
O/C E.W.
FLOOR SLOPE
FLOOR SLOPES SHALL BE
REASONABLY UNIFORM AND
COMPLY WITH ARTICLES 5.6.1
THRU 5.6.3
32' ]_
THE SLOPE OF THE FLOOR FROM
THE SHALLOW END WALL
TOWARDS THE DEEP AREA SHALL
NOT EXCEED I FOOT IN 7 FOOT
CYCOLAC MAIN
35'
(NO SCALE)
8' """ WALLS
SHALL
NOT
6" THICK SLOP
GRnER
THAN 116
3'