Loading...
HomeMy WebLinkAboutApproved PlansMETAL ROOFING OVER WOOD PURLINS ATTACHED PER ROOF ATTACHMENT 2X4 WOOD PURLINS ATTACH TO EACH TRUSS WITH (2)- #12 X 3" LONG SCREWS PRE-ENGINEERED WOOD TRUSSES AT 24" O.C. (MAX SPAN) "SIMPSON" HTS20 WITH (20)- 10d X 1 1/2" EACH TRUSS 2X6 CEDAR FASCIA (2)- 5/8" THRU BOLTS EACH BEAM TO PILE (4)-2X12 WOOD HEADER WITH GLUED AND NAILED W/ 16d NAILS AT 8" O.C. STAGGERED TOP AND BOTTOM BOTH SIDESEACH COURSE 9" DIAMETER (MIN.) PRESSURE TREATED WOOD PILE FINISHED GRADE PILE BURRIED 48" DEEP (MIN.) IN WELL COMPACTED SOIL T� AL PILE DETAIL nts... (2)- 5/8" THRU BOLTS �-- (2)- 5/8" THRU BOLTS — (2)- 5/8" THRU BOLTS I BEAM REDUCED TO (2)- 2X12 AT PILE - 2X 12 WOOD HEADER WITH L GLUED AND NAILED W/ 16d NAILS PILE PER PLAN AT 8" O.C. STAGGERED TOP AND BOTTOM BOTH SIDESEACH COURSE TYPICAL PLAN VIEW AT PILE / BEAM CONNECTION nts... a _ (3)- 16dNA,ILS (TYPICAL) 2 X 4 "X" BRACING AT RIDGE AND 6 FEET O.C. EACH SIDE OF RIDGE 2 X 4 SPRUCE OR BETTER LATERAL BRACE AT 6 FEET O.C. FASTENED TO TOP OF BOTTOM CHORD OF TRUSSES WITH (2) - 16d NAILS EACH, AT GABLE END TRUSS AND 4 TRUSSES BACK OPENCEILING - --- P.T. 2 X 4 CONTINUOUS WITH'/2'=� LAG BOLTS AT 24" O.C. WITH n 2" X 2" X 1/8" WASHERS 1 REINFORCE EACH VERTICAL MEMBER OF GABLE END TRUSS WITH 2 X 4 T- BRACE WITH 16 D 1 V NAILS AT 8 INCHES O.C. PLAN VIEW T-BRACE RO�FING PER PLAN -2X CEDAR FASCIA TI-I I SOFFIT WITH 2" LONG RINGSHANK NAILS AT 6" O.C. A PERIMETER AND FIELD 1— 2X4 LADDER FRAMING AT 12 INCHES O.C. GABLE END TRUSS _ 5/8" TI-I 1 WITH 10d NAILS AT 6" O.C. PERIMETER AND FIELD GABLE END FASTENED TO J SLEEPER WITH 16 D COMMON NAILS AT 12" O.C. STRAP GABLE END TRUSS WITF "SIMPSON" LSTA 15 AT 48" O.C. WITH (12) - 10d X 1 V," NAILS (2)- 5/8" THRU BOLTS EACH BEAM TO PILE (2)- 2X12 WOOD HEADER WITH GLUED AND - NAILED W/ 16dNAILS AT 8" O.C. STAGGERED TOP AND BOTTOM BOTH SIDESEACH COURSE GABLE END DETAIL tits... Planting & Development Services Department owl Building & Regulations Division Product Review Affidavit Building Permit # Owners Name Rl E 47 U Applicant: Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment windows N A Mullions Flied Glass Block Glass Skylights sliding Glass Doors Swing Type Dares e French Doors Garage Doors Hurricane Protection Roor Ventilation Roaring Material orris✓ coeeutno✓6 � fV FI,N g555r I NIA' Pt IG PonFrN <✓ (a. TTC,c+Lt—CE K3-r oN Pa..s.N I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: Signature: - - PAUL WELCH P.E. ON PLAN Design Prot• . PAUL WELCH P.E.I Cert. No. 29945 Date: SCOPE OF WORK - CONSTRUCT POLE BARN PER PLAN NOTES: 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2014. 5) STRUCTURE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. STRUCTURAL NOTES I) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 4) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICI ES. 5) ALL THRU BOLTS SHALL BE GRADE 55 GALVANIZED. r _w0 11 IS I GI`pe � Ibl-t1r 3 (0 p � File Copy CONCEALED FASTENERS OR ATTACHMENTS Planning& Development Services Department ARE THE RESPON$IBILJTYOFTHE I, Building & Code Regulations Division C(1NTRAG`TOR4F RECORD 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance .fh'E5E PLANS AND ALL PROPOSED WORK Project Name: BEATH POLE BARN ARE SUBJECT TO ANY CORRECTIONS Project Address: 18003 BRIDLE WAY REQUIRED BY -FIELD INSPECTORS THAT MAY 85 NECESSARY IN ORDER TO Permit#: Occupancy Type: U Construction Type: 09MPLYVIONALAPPOCABLICODES, INSTRUCTIONS FOR USE: a This certification must be completed, signed, and sealed by the design professional of record. a Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) * 1103 - villX! o Residential Addition ST. LUCIF 0-011 Y ALTRTrTN( DIVISION o Any accessory structure requiring a building permit RFVIFµ`ED FOR Qt MPLIANCt Rt v`IL t' u,"�1Y o Any non-residential structure. DATE _`I/�/1 + * Note: Form not required for interior renovations provided that no exterior structural elementVhW4FA�f}I W1(MIT MUST BE KEPT ON JOB certain minor building permits at the discretion of the local building official. Contact the # abovej;rVe6NrctAPTION WILL BE 4 ADE. DESIGN PARAMETERS AND ASSUMPTIONS • USED (complete all that ao IPam' ) 1. DESIGN CODE: Florida Building Code 2014 Edition with 20 _Supplements using ASCE 7-10 2. Structure Designed as (check one): _ Enclosed X Partially Enclosed _Open 3. Risk Category: X I_ II_ III IV Exposure Category: _ B X C D 4. Design Wind Velocity 150 mph 116 ASD N/A LRFD End Zone Width: 5 It S. Mean Roof Height: 13.7 ft Roof Pitch: s :12 Parapet: N/A It 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 23.6 23.6 23.6 38.6 38.6 N/A Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: -32.5 -49.2 -68.4 -41.1 -48.5 N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony: _N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? -&_Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Paul Welch P.E. 29945 / 5115 Print Name Cert # & Co. Cert Auth. Paul Welch Inc. ON PLAN 3/15/2017 Signature, Date, and Seal SLl Form # 020-12 Revised 3/15/12 (JS) - S N 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name & Address PAUL W,ELCHINC. ( MECHANICAL ELECTRICAL CIWL ENGINEERING 1984S.W. Ell TMOREST SUITE ,# f f4 PORTST. LUCIE, FL 34984. PHONE l77EI785-9888 E-MAIL PYVELCHINCOAOL.COM PAUL WELCH, P.E. FLA REGNo 29945 MAR 1 5 281 i • i� 1. M 1 ( 1 f A. Y d Mille P e 'tom T`' PANEL FASTENER #9-15 OR #10-14 X 1.5" LOOOD - SCREWS 0 MAX 12' O.C. ,.,/ FASTENER PATTERN NOM. 2 " X 7:" (MIN) SYP UNTREATED SUPPORT SPACING = 24" O.C. (DESIGN BY OTHERS) ALLOWABLE UPLIFT PRESSURE = 70,25 PSF PANEL FASTENER:#9-15 OR #10-14 X 1 Y2" LONG, HEX -BEAD SCREW WITH NEOPRENE WASHER IN THE RIB OF THE PANEL. ALL FASTENERS TO BE CORROSION RESISTANT. FASTENERS SHALL BE INSTALLED WITH SCREWS SPACED PER BELOW: ZONE 1, 2, & 3:SCREW SPACING 12" O.C. ACROSS PANEL WIDTH AND SPACING 24" O.C. PANEL ENDS: SCREW SPACING 12" O.C. ACROSS PANEL WIDTH METAL ROOF PANELS SHALL BE SECURED TO THE SUPPORTS IN ACCORDANCE WITH THE APPROVED MANUFACTURER'S FASTENERS. METAL PANELS SHALL BE ATTACHED PER MANUFACTURER'S SPECIFICATIONS AND DETAIL THIS SHEET. ROOFING ATTACHMENT nts... PER FL# 9555.1 5-V CRIMP UNION CORRUGATING COMPANY PRODUCT DESIGN PRESSURE: -70.25 PSF TRUSS CONNECTOR SCHEDULE TRUSS ID BEARING POINT TRUSS ACTUAL CONNECTOR CONNECTOR FASTENERS NOTES UPLIFT ID UPLIFT DESIGN A EACH I 1130 (1)- HTS 20 1450 (20) -10d GEA CONT. 248 PLF ( )-LSTA15 1110 (12)- 10d ( 1 STRAP AT EACH END AND AT48" O.C. TRUSS COMPANY CHAMBERS LAYOUT DATE 2 22 2017 1 CUT -SHEET DATE I 2 24 2017 NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED. TRUSS NOTES: 1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER. 2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) CONTRACTOR TO VERIFY ALL ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING, AND INSTALLING TRUSSES. 4) TRUSS TO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY. 5) SEE TRUSS CONNECTOR SCH. FOR TRUSS TO WALL CONNECTIONS. gm .% .... wv — '✓ /"v !"a ""r w 4 `+„" 'q+..,� � 4ay,-w..,,y�\. ,n}Yk ..ey .,k '�y.,�a r /"� rs,.r" ✓f ..,h T' Y + A "� �.s'�yr f J•- ` 't��,ty •, .^.. i. `"� „'� f„A✓ �f' YI" /'. ,r' • r' eM fI /�`/� ;i"` J:`v b.4�Yl'I.fi �llp¢MR f! 'air: :. ; .4y +" a• � 4 l `'�+ R f ✓ �2��`�.�N�V r wr J r v. f "•4 ..i ,;. ..�"' h.. ti.- �. '�. • "+v+� ham, f,,.t A y F. t � . PAUL. WELCH INC MECHANICAL ELECTRICAL CIVIL ENGINEERING - -- - Y984S.W.. BILTMOREST. SUITE' 114 PORTST. LUCIE, FL 34984 PHONE (77,2) 785 - 9888 E-MAIL PWELCH/NC@AOL. COM PA!UL LVELCAI, P ,5 FLA REG NO. E.9945 MAR 1 5 207 A=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. 5PAGING NOTE l� {t' It t �t r , rc* A DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span or less A 30' to 60' Span 60 degrees Sprea er Bar or less — 1 /2 —► Tag Line span approx. REFER TO BCSI Truss must be set this way if crane used, Truss s an example, your truss may not match. nsis: crane operator sets truss this way. h'oy Approx 2/3 to_ _� Line 1/2 of Span REFER TO BCSI ,ss must be set this way if crane used. This is an example, truss may not match. Insist crane operator sets truss this way. All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses ® are installed. A1R "A Ill E:>I IE=RZ Ill OT9= UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR ` 'HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIRE aEl THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. Carrying Girder For Truss to Truss Connections see hanger/connector schedule in engineering package. INDICATES LOAD BEARING REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 11 ABOVE FINISHED FLOOR Nails must be as shown. Guide tabs o Dome angle nails. A ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24' IN LENGTH A Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN NOTES: * ALL BEAMS ARE BY OTHERS. upset=1/4" heel=41/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 10' TYPICAL END DETAIL es File Cfoby FABRICATION AGREEMENT' •�TRU&4ES CANNOT BE STARTED UNTIL THI3 AGREEMENT IS SIGNED & RETURNED ' The lapel description of the property where the trusses will be Installed Is: The.undemlgned acknowledges and egress: - 1. Trusses will be made In strict accordance with this truss placement diagram layout, ufilch Is the sole autholity for determining successful fabrication of the trusses. �3. Atl dlmenalons kt this layout have been verified by the undersigned. :•,3'..Unlaee wrldan III Is provided by certified mall to Chambers Truss within ten (10) j gays cf delivery the undersigned apace that no backcharges. will be allowed. In the event le fumished Chambers Trues she have three (3) bu�nesa days In which such wrilten nodes toybepin ropelre required, or to substitute other mosses, at Chambers option. acknovedges mcelpt of "BCSI 1-03" summary sheet by TPI & WTCA. ' ;': ,4�The undersigned . 4 Oellvary Is to Job ells. It la the buysrs'responalbility to make the lob site suitable for delhlery. Chambers Truss has the sole euthodty to determine the sultablllty of the job site of a polticn of the Job ells for dalhrery. Chambers Trues vAII be responsible for tlump delivery only. The buyer Is reepomilbta for additional delivery expanses d Chambers Trues hea to redellver bet;6ece Job site le not prepared for delivery or buyer Is not prepared for delivery of trusses. Buy6ah responsible to Chambers Trues for towing coats due to ells conditions. - i Q:Priee ae shown In parapmph 7 below la aubl to change H any changes ere. made lo jhls.(ayput. A S60 per hour fee for revisions may be charged try Chamber Truss. ' . '7p; is la a PURCHASE ORDER 10 Chambers.Trusa of the sum agreed to, or d nQ' price. Involoa will be made on delivery and paid within terms of nit *glob• ant a reasonebto onCdalivery. Invoice may be made at scheduled date of delivery d buyer cannot accept 011Nary'of fabricated trusses. The undersigned agrees to pay Chambers.TNss reasonable ettbmeys fee for collections In event of payment not timely made. 1-12 %per month service - 'charge will be added for all sums not paid within terms. '. ;S: Signature or Indlals anywhere on this sheet constitutes agreement to all terms herein. ,..S; In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees payment when due of any and all Indebtedness owed to . Chambers Truss by any entity receiving material and the undersigned agrees to pay such Including attorneys fees, If default In payment for material be made by the indebtedness recipient. of any 110gagon concerning this agreement, the dams fumished hereunder .. . 10, In the event .or payments referred to herein, the parties agree that the sole venue for any such action will . 'be Saint buds County. Florida. 11A. Design responsibilities are per "National Standard And Recommended Guidelines On Rasponelbllltles For Construction Using Metal Plate Connected Wood.Trusses ANSUTPUWTCA 4.2002'* GATED .._.V .. . SIGNED OR TfILF 4 . jsprealkrbazrrraYbaeecj4,IledP�"HCSI1-03 to pleuenttrtjlaYB�dartlaga' ,Muitiple ply trusses must be fastened together per engineering $ei'ore they are set failure to do so can result In roof collapse.' m ore and permanent bracing are required and can save Ilfe' q..,P rY and property and Is the responslblllty of the truss erector. Sttydy the contents of the Information packet Included on delivery before setting trusses. 11+1'.t9^ mustbesetand braced perdeslgn t9 PleveldWlaYBdalrta8e ' ."gTrusses Trueses must be set plumb and square Do noVeet bunks or stack of plywood, roofing material or any ttv this can cause collapse. 2 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT other edhoentiI loads on ss , 'iDO NOT SET TRUSSES USING THISUSE LAYOUT DELIVERED WITHTRUSSES T (CHAMBERS TRUSS INC 3105 Oleander Avenue . 3 Fort Plerce; Florida 34982-6423 ; 800-551-5932 FdrtPlerce 772.465-2012 Fax 772.465.3711 1., Veto Beach 772.569-2012 Stuart 772.286-3302 I;{r�;Wait Sitar CHAMBERSTRUSS.COM ' 92.0/93.2 MITEK 4.2 DESIGN CRITERIA County SAINT LUCIE Building Department FORT PIERCE Wind Design Criteria ASCE 7-2010 Wind Design Method Main Wind Force Resisting Roofing Material Metal Roof Loading in PSF Roof R.D.L. Top Chord Live 20 Top Chord Dead 7 4.2 Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 TOTAL Load 37 7.2 Duration Factor 1.25 Wind Speed 160mph Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Sheeting by builder. Highest Mean Height 15'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2014 R.U.L.=Restraining Uead Load C.B.=Continuous Bracin Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Enaineer of Record- Chambers Truss Inc. Drawing Name: 74160 Scale: 1/4 = 1' 19 total trusses, 2 different trusses. MI 4: RLC ACAD: RLC Reviewed By: A ,X*V-r r Date: 02/22/17 FOR PAL LCH MICHAEL BEATH MECHUELECT-CVINLENG DESCRIPTION: OR ST.LUBILTMOIE3L3T. 494 PORT ST. LUCIE, FL 34964 PAUL WELCH, P.E. FLA REG NO29945 POLE BARN �1�/ PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE V�v tt 74160 PAR 1 6 2011