Loading...
HomeMy WebLinkAboutProduct Approval (2) r Ile C®pyFLORIDA 130PARNONT'dOt r f IiE ® iness & ,Pr.o4ssipne t. BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications I FBC Staff BCIS Site Map Links I Search Florida Product Approval USER.Public User E w d ., pr Product Aporoval Menu>Product or Application Search>Application Lis[>Application Detail FL# FL11651-112 Application Type Revision Code Version 2014 Application Status Approved _ Comments Archived r Product Manufacturer Gulf Coast Supply&Manufacturing, LLC. Address/Phone/Email 4020 S. W.449th Street Horseshoe Beach,FL 32648 (352)498-7852 ray@gulfcoastsupply.com Authorized Signature Ray Bowen ray@gulfcoastsupply.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer FJ Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Daniel S. Kuhn the Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden Validation Checklist-Hardcopy Received Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Eng.pdf FL11651 R2 COI Letter of Name change.pdf Referenced Standard and Year(of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL1897 2004 UL580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/01/2015 Date Validated 07/10/2015 Date Pending FBC Approval 07/18/2015 Date Approved 08/18/2015 Summary of Products Go to Page �— Page 1/2 FL# Model, Description Number or Name 11651.1 0.032" 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Aluminum 5V Crimp Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 1 R2 0325vCrimo 15-32Plywood NonHVHZ odf HVHZ: No FL11651 R2 II 14FL11651 1 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 1 R2 0325vCrimp 15-32Plywood NonHVHZ odf Pressure: +N/A/-108.5PSF Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c.Install per manufacturers details. Not for use in HVHZ Zones. 11651.2 0.032" 0.032"Aluminum Gulf Lok 16"Wide Roof Panel over 15/32" Plywood Aluminum Gulf Lok Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 15-32Plywood NonHVHZ.pdf HVHZ: No FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL116S1 2 R2 032Gulfl-ok 16 15-32Plywood NonHVHZ.Pdf Pressure: +N/A/-116.OPSF Created by Independent Third Party: Yes Other: -52.5 psf @ 5 3/16" o.c.fastener spacing. -116.0 psf @ 5 3/16"o.c.fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.3 1"24ga. Gulf 1"Gulf Snap 24 Ga. 17"wide Roof Panel over 15/32" Plywood Snap Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.pdf HVHZ:Yes FL11651 R2 II 14FL11651 3 R2 1 24GulfSnap 17 15-32Plywood HVHZ..pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 3 R2 1 24GulfSnap 17 15-32Plywood HVHZ..pdf Pressure: +N/A/--131.OPS Created by Independent Third Party: Yes Other: -67.3 psf @ 24"o.c. clip spacing. -131 psf @ 6" o.c. clip spacing.Install per manufacturers details. For use in HVHZ Zones. 11651.4 1"24ga. 1"VersaLoc 24ga 16.5"Wide Roof Panel over 15/32"Plywood VersaLoc Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 4 R2 24VersaLoc SR 16.5 15-32Plywood HVHZ..pdf HVHZ:Yes FL11651 R2 II 14FL11651 4 R2 Metal Roof Panel Detail..pdf Approved for use outside Verified By: Dan Kuhn,P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 4 R2 24VersaLoc SR 16.5 15-32Plywood HVHZ..pdf Pressure: +N/A/-138.5PSF Created by Independent Third Party: Yes Other: -71 psf @ 24"o.c. clip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.5 1"VersaLoc 1"VersaLoc.032"Aluminum over 15/32" Plywood .032" Aluminum Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc SR 16 15-32Plywood HVHZ..pdf HVHZ:Yes FL11651 R2 II 14FL11651 5 R2 Metal Roof Panel Detail..pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 5 R2 lin 032VersaLoc SR 16 15-32Plywood HVHZ..pdf Pressure: +N/A/-101.OPSF Created by Independent Third Party: Yes Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.6 1.5" 24ga. 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/32" Plywood Gulf Snap Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 6 R2 1.5 24GulfSnap 16 15-32Plywood HVHZ..pdf HVHZ:Yes FL11651 R2 II 14FL11651 6 R2 Metal Roof Panel Detail..pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 6 R2 1.5 24GulfSnap 16 15-32Plywood HVHZ..pdf Pressure: +N/A/-116.OPSF Created by Independent Third Party: Yes Other: -86.0 psf @ 24"o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6"o.c. clip spacing. Install per manufacturers detals. For use in HVHZ Zones. 11651.7 1.5" 24ga. 1.5"VersaLoc 24ga. 16"wide Roof Panel over 15/32" Plywood VersaLoc Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 7 R2 1.5 24VersaLoc 16 15-32Plywood HVHZ..pdf HVHZ:Yes FL11651 R2 II 14FL11651 7 R2 Metal Roof Panel Detail..pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc 16 15-32Plywood HVHZ..pdf Pressure: +N/A/-123.SPSF Created by Independent Third Party: Yes Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12" o.c.clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.8 FM "24ga. 24 Ga. 2" MegaLoc 18"wide Roof Panel over 15/32"Plywood egaLocc Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 8 R2 24MegaLoc 18 15-32Plywood NonHVHZ.pdf HVHZ: No FL11651 R2 II 14FL11651 8 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 8 R2 24MegaLoc 18 15-32Plvwood NonHVHZ.pdf Pressure: +N/A/-108.5PSF Created by Independent Third Party: Yes Other: -71.0 psf @ 24"O.C. clip spacing. -108.5 psf @ 12"o.c. clip spacing.Install per manufacturers details. Not for use in HVHZ Zones. 11651.9 24 Ga. Gulf 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood Lok Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 9 R2 24GulfLok 16 15-32Plvwood NonHVHZ.pdf HVHZ: No FL11651 R2 II 14FL11651 9 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn,P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 15-32Plvwood NonHVHZ.pdf Pressure: +N/A/-96.7PSF Created by Independent Third Party: Yes Other: -81.75 psf @ 10-1/4" o.c.fastener spacing. -96.76 psf @ 5-1/8" o.c.fastener spacing. -121.75 psf @ 5-1/8" fastener spacing. -161 psf @ 5-1/8"fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.10 24 Ga. Gulf 24 Ga. Gulf Seam 16"Wide Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Seam Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 10 R2 24GulfSeam 16 1x4 15-32Plywood NonHVHZ.pdf HVHZ: No FL11651 R2 II 14FL11651 10 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 10 R2 24GulfSeam 16 1x4 15-32Plvwood NonHVHZ.pdf Pressure: +N/A/-93.5PSF Created by Independent Third Party: Yes Other: -93.5 psf @ 18" o.c. Install per manufacturers details. Not for use in HVHZ Zones. 11651.11 24 Ga. Gulf 24 Ga. Gulf Seam, 1 3/4"Snap Lock, 18"Wide Roof Panel over 15/32" Plywood Seam Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 11 R2 24GulfSeam 18 15-32Plvwood NonHVHZ.pdf HVHZ: No FL11651 R2 II 14FL11651 it R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 it R2 24GulfSeam 18 15-32Plvwood NonHVHZ.pdf Pressure: +N/A/-108.5PSF Created by Independent Third Party: Yes Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.12 26 Ga. 5V 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood Crimp Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 12 R2 265vCrimp 15-32Plvwood HVHZ.pdf HVHZ:Yes FL11651 R2 II 14FL11651 12 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E.75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 12 R2 265vCrimp 15-32Plywood HVHZ.pdf Pressure: +N/A/-156.5PSF Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c.fastener spacing. -156.5 psf @ 6" o.c.fastener spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.13 26 Ga: 5V 26Ga.-5V Crimp over 15/32 Plywood Crimp Limits of Use. Installation Instructions, Approved fog use ie FL11651 R2 II 14FL11651 -13 R2-265JCrimp 15-32Plywood NonHVHZ.pdf - - - - - - - - HVHZ: No FL11651 R2 II 14FL11651 13 R2 Metal Roof Panel Detail.pdf Approved for.use outside Verified P.E-.75519 HVHZ Yes -Created-by Independent Third Party:Yes 1nipactResistant: N/A. Evaluation Reports Design FL11651-R2 AE-14FL1-1-651 13-R2-265,Crimp 15-32Plywood-NofiHVHZ.pdf ;Pressure:+N/A/-131.PSF Created 6y Independent Third Party:-Yes Other: -94.25 psf @ 16 o.c.fastener pattern. -131.0 psf @ 16"o.c.fastener: pattern_ Install peg manufacturers details:Not ;for use in HVHZ Zones: 11651.14 26 Ga. 5V 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32"Plywood Crimp Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 14 R2 265vCrimp 1x4 15-32Plvwood NonHVHZ.pdf HVHZ: No FL11651 R2 II 14FL11651 14 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 14 R2 265vCrimp 1x4 15-32Plvwood NonHVHZ.pdf Pressure: +N/A/-156.5PSF Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c.fastener spacing.-156.5 psf @ 6" o.c.fastener spacing.Install per manufacturers details. For use in HVHZ Zones. 11651.15 26 Ga. Gulf 26 Ga. Gulf Lok 16"Wide Roof Panel over 15/32"Plywood Lok Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 15 R2 26GulfLok 16 15-32Plywood HVHZ.pdf HVHZ:Yes FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E.75519 ` HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16 15-32Plvwood HVHZ.pdf Pressure: +N/A/-161.OPSF Created by Independent Third Party: Yes Other: -63.5 psf @ 5 3/16" o.c.fastener spacing. -121.75 psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16"o.c.fastener spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.16 26 Ga. Gulf 26 Ga. Gulf Lok 16"Wide Roof Panel over 15/32" Plywood Lok Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 16 R2 26GulfLok 16 15-32Plvwood NonHVHZ.pdf HVHZ: No FL11651 R2 II 14FL11651 16 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 16 R2 26GuifLok 16 15-32Plywood NonHVHZ.pdf Pressure: +N/A/-63.SPSF Created by Independent Third Party: Yes Other: -63.5 psf @ 5 3/16" o.c.fastener spacing. -121.75 psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16"fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.17 26 Ga. 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood GulfPBR Limits of Use Installation Instructions Approved for use in FL11651 R2 II 17 R2 26GulfPBR 15-32Plywood NonHVHZ.pdf HVHZ: No FL11651 R2 II 17 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 17 R2 26GulfPBR 15-32Plywood NonHVHZ.pdf Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other: -59.25 psf @ 24" o.c.fastener pattern. -154.75 psf @ 12" o.c. fastener pattern. Install per manufacturer details. Not for use in HVHZ 11651.18 26 Ga. 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32"Plywood GulfPBR Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 18 R2 26GulfPBR 1x4 15-32Plywood HVHZ.pdf HVHZ:Yes FL11651 R2 II 18 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 18 R2 26GulfPBR 1x4 15-32Plywood HVHZ.pdf Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes Other: -100.5 psf @ 24" o.c.fastener spacing. -151.75 psf @ 12"fastener spacing. Install per manufacturer's details. For use in HVHZ Zones 11651.19 26 Ga. 26 Ga. GulfPBR over 15/32"Plywood GulfPBR Limits of Use Installation Instructions Approved for use in FL11651 R2 II 14FL11651 19 R2 26GulfPBR 15-32Plvwood HVHZ.pdf HVHZ:Yes FL11651 R2 II 19 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 14FL11651 19 R2 26GulfPBR 15-32Plywood HVHZ.pdf Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other: -60.5 psf @ 24"o.c. fastener spacing. -154.75 psf @ 12"o.c.fastener spacing. Install per manufacturer's details. For use in HVHZ Zones. 11651.20 26 Ga. 26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32" Plywood GulfPBR Limits of Use Installation Instructions Approved for use in FL11651 R2 II 20 R2 26GulfPBR 1x4 15-32PIVwood NonHVHZ.pdf HVHZ: No FL11651 R2 II 20 R2 Metal Roof Panel Detail.pdf Approved for use outside Verified By: Dan Kuhn, P.E. 75519 HVHZ:Yes Created by Independent Third Party: Yes Impact Resistant: N/A Evaluation Reports Design FL11651 R2 AE 20 R2 26GulfPBR 1x4 15-32Plvwood NonHVHZ Ddf Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes Other: -94.25 psf @ 24" o.c.fastener spacing. -151.75 psf @ 12"fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones Go to Page �— Page 1/2 Back Next Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter455,F.S.must provide the Department with an email address if they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here Product Approval Accepts: ® ® eChecY. Credit Card Safe 'CoA , ® . 0190 A ! ® m . Gulf SUPPLY & MANUFACTURING NIP 5 V ""nD 26 GUAGE SVCRIMP PANEL OVER 1X4 WOOD PURLINS OVER 15/32" PLYWOOD -ORIDA PRODUCT APPROVAL NO. 11 TIV[ Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC- 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15132"Plywood Florida Product Approval #11651.14 R2 Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 —D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. � 1EL S N .•k �. 14429 SW 2nd Place, Suite G30 SOP O\C ENs•�ti'L'; Newberry, FL 32669 F ; *; No. 75519 Engineer Evaluator: Dan Kuhn, P.E. #75519 ;0- STATE OF Florida Evaluation ANE ID: 10743 `�.s;c� oR yo 11�0NA L EN • Validator: 0.630�20 15 Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 FL#11651.14 R2•JUNE 15,2015 RORI-DA MODUC �A PPR 0",L Gul Cozi'� SUPPLY & MANUFACTURING RIMP . . . PURLINS . . • . FLORIDA PRODUCT APPROVAL NO. 11651 . 1R TNI Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2, 1504.7. Product Description: 5V Crimp Roof Panel, Minimum 26 Ga. Steel, 24" Coverage, through fastened roof panel over Minimum 1x4 Wood Purlins over minimum75/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/s" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal '/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 1x4 No. 2 SYP wood purlins over min. 1-A2" thick, APA Rated plywood over supports at maximum 24" O.C. The 1x4 wood purlins shall be fastened to the plywood with minimum 8D x 2Y2" Ring Shank Nails at 4" O.C. Design of 1 x4 wood purlins, plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table "A" Maxim'uiri TotalUphft Deslg"n%Pressure � 149 �`5psf I _ �x E . , Fastener Pattern 12"-12" Fastener Spacing x 116 OTC Design Pressure includes a Safety Factor= 2.0. FL#11651.14 R2•JUNE 15,2015 11670 ISLAND LAKES LANE,BOCA RATON, 33498 -FL COA#30464 'Coz� � . . . . . Gulf SUPPLY & MANUFACTURING ImD- 5VCRIMP PANEL OVER • • OVER • • TNI Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04- Uplift Test for Roof Covering Systems. • FM 4471-1992, Section 4.4 Foot Traffic Resistance Test Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0053-T-05, Dated 05/18/2005 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0378T-11 B, Dated 02/15/2012 3. Certificate of Independence By Dan Kuhn, P.E. (FL#75519) @ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. 3. The FM 4471-95 test standard is equivalent to the FM 4471-1992 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. FL# 11651.14 R2 •JUNE 15,2015 ® o ® ® A A ENGINEERING,KUHN 11670 ISLAND LAXES LANE, BOCA RATON, 33498 •A a .4 FLORIDA PRODUCTAPPROVAL Gulfc&ist SUPPLY & MANUFACTURING 5VCRIMP WOOD PURLINS . . . . FLORIDA PRODUCT A• • • • NOO . 11651 . 12 TNl Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 11651.14R2 •JUNE 15,2015 PAtODUCT eL G61iCoA SUPPLY & MANUFACTURING 5VCHIHIP 26 GLIAGE 5VCRIMP PANEL OVER • • OVER • • TN1 ENGINEER LOAD TABLE: 26 Ga. 5V Crimp Panel over 1x4 Wood Purlins over 15/32" Plywood Buildings having a Roof Mean Heights 20'-0"'," Roof Slope: 2"/12" - 12"/12" Gable or Hip Roof; Wind Speeds 120- 180mph, Exposure C, Risk Category ll, Enclosed Building, based on Florida Building Code 2014. 120 130 140 150 160 170 180 WIIND FASTENER SPEED (MIN. SUBSTRATE ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 #9-15x1.5" 1x4 Wood 16" 16" 16" 16 16" 16 16" Purlins ZONE 2 #9-15x1.5" 1 P Wood d 16" 16" 16" 16" 16" 16" 16" ZONE 3 #9-15x1.5" 1x4 WoodPurlins 16. 16" 16" 16" 16" 16 16" 1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4"TALL. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-149.25 PSF Q 16" O.C. PSF BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)SUBSTRATE: 1X4 WOOD PURLINS OVER MIN.15/32" THICK PLYWOOD.WOOD PURLINS ATTACHED TO PLYWOOD W/MIN. 8D X 21/2" RING SHANK NAILS AT 4" O.C. PURLINS AND PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FBC 2014 5.)ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KID=0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 Note: Dimension(a)is defined as 10% of the minimum width of the building or ZONE 2 HIP ROOF ZONE 3—,,I 40% of the mean height of the roof,whichever is smaller,however, (a)cannot be r ——_ a less than either 4% of the minimum width of the building or 3 feet. 1 x 4 Wood Purlins @ 16" O.C. attached to Plywood -RIDGE -- % , w/(1) 8d x 2.5" Ring Shank Nails @ 4" O.C. 12" 12" ZONE \� \� t �t Panel Lap EAVE ZONE GABLE ROOF a 1 #9-15 x 1-1/211 Min. 15/32" Plywood Ll — ---- �� a ( ) -'- ----- ------- 12u-12u Fastener Pattern @ 16" O.C. < I I RIDGE --------- -------- -- --I- a ZONE 1 I I -�---\----------------------- -ZONE 3 EAVE FL# 11651.14 R2 •JUNE 15,2015 1 ® o © � W � ® ® ® Gulfs a- SUPP26 GLIAGE 5VCRIMP PANEL OVER 1X4 WOOD PURLINS OVER 15/32" PLYWOOD LY & MANUFACTURING I TM a 1 x 4 Wood Purlins @ 16" O.C. attached to Plywood w/(1 ) 8d x 2.5" Ring Shank Nails @ 4" O.C. 1211 1211 At Panel Lap (1 ) #9-15 x 1 -1/211 Min. 15/32" Plywood 12"-12" Fastener Pattern @ 1611 O.C. ,11 CEty *, No. 75519 � V- STATE ' OF :Q. � OR1DP' ••��Ci�;` 7_3 o7Zo15 oi FL# 11651.14 R2 •1UNE 15,2015 KUHN • 1 •ENGINEERING,BOCARATON, 49: FLCOA#30464