FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LH-2369-MW Builder Name: LENNAR HOMES
Street: 9500 POINCIANA CT Permit Office:
City,State,Zip: FORT PIERCE,FL, Permit Number:
Owner: 2369 MODEL LOT 192 @ MEADOWOOD Jurisdiction:
Design Location: FL,Fort Pierce
_1. New construction or existing New(From Plans) 9. Wall Types(2164.7 sqft.) Insulation Area
12. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1964.70 ft2
b.Frame-Wood,Adjacent R=11.0 200.00 ft2
3. Number of units,if multiple family 1 c.N/A
R= ft2
4. Number of Bedrooms . 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (2370.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 2370.00 ft2
6. Conditioned floor area above grade(ft2) 2369 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(332.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:BED 3 6 300
a. U-Factor: Dbl,U=0.53 266.00 ft2
SHGC: SHGC=0.24
b. U-Factor: Dbl,U=0.56 66.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.23 a.Central Unit 42.5 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 42.5 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 5.090 ft.
Area Weighted Average SHGC: 0.238 14. Hot water systems
8. Floor Types (2369.0 sqft.) Insulation Area a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2369.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.140
Total Proposed Modified Loads: 62.31 PASS
Total Baseline Loads: 65.15
I hereby certify that the plans nd specifications covered by Review of the plans and O�SgE ST�q?�
this calculation are in complia a with the Florida Energy specifications covered by this
Code. calculation indicates compliance � .r,,;'' '_' •�
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes. ��-
with the Florida Energy Code. COD y �
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed.in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
tL-st report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.040 Qn for whole house.
4/12/2017 5:40 PM EnergyGauge@)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
WRM R405-2014
PROJECT
Title: LH-2369-MW Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 2369 Lot#
Owner: 2369 MODEL LOT 192 @ ME Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: LENNAR HOMES Rotate Angle: 0 Street: 9500 POINCIANA CT
Permit Office: Cross Ventilation: No County: St.Lucie
Jurisdiction: Whole House Fan: No City,State,Zip: FORT PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
'Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 2369 23690
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BED 3 176 1760 No 1 3 1 No Yes Yes
2 LAUNDRY 72 715 No 0 1 No Yes Yes
3 BATH 2 105 1050 No 0 1 No Yes Yes
4 WIC BED 2 22 220. No 0 1 No Yes Yes
5 BED 2 154 1540 No 1 1 No Yes Yes
6 BREAKFAST 105 1045 No 0 1 No Yes Yes
7 KITCHEN 220 2200 No 0 1 No Yes Yes
8 DINING ROOM 152 1523 No 0 1 No Yes Yes
9 GREAT ROOM 544 5440 No 0 1 No Yes Yes
10 FOYER 96 960 No 0 1 No Yes Yes
11 MASTER BATH 192 1920 No 0 1 No Yes Yes
12 TIOLET MASTER 22 220 No 0 1 No Yes Yes
13 WIC SML MASTER 46 455 No 0 1 No Yes Yes
14 EXT MASTER WIC 78 780 No 0 1 No Yes Yes
15 MASTER SUITE 286 2860 No 2 1 No Yes Yes
16 SITTING ROOM 99 990 No 0 1 No Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BED 3 25 ft 177.2 ftz ---- 0 0 1
2 Slab-On-Grade Edge Insulatio LAUNDRY 6.5 ft 71.5 ftz ---- 1 0 0
4/12/2017 5:40 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
RM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
3 Slab-On-Grade Edge Insulatio BATH 2 14 ft 105 ft2 ---- 1 0 0
4 Slab-On-Grade Edge Insulatio WIC BED 2 4 ft 22 ft2 ____ 0 0 1
5 Slab-On-Grade Edge Insulatio BED 2 24.5 ft 154 ft2 ---- 0 0 1
6 Slab-On-Grade Edge Insulatio BREAKFAST 18 ft 104.5 ft2 -__- 1 0 0
7SIab-On-Grade Edge Insulatio KITCHEN 1 ft 220 ft2 ---- 1 0 0
8 Slab-On-Grade Edge Insulatio. DINING ROOM 12 ft 152.3 ft2 - 1 0 0
9 Slab-On-Grade Edge Insulatio GREAT ROOM 17 ft 544 ft2 ---- 0 0 1
10SIab-On-Grade Edge Insulatio FOYER 8 ft 96 ft2 ---- 1 0 0
11SIab-On-Grade Edge Insulatio MASTER BATH 26 ft 192 ft2 --__ 1 0 0
12SIab-On-Grade Edge Insulatio TIOLET MASTER 4 ft 22 ft2 -_-- 1 0 0
13SIab-On-Grade Edge Insulatio WIC SML MASTE 1 ft 45.5 ft2 _--- 0 0 1
14SIab-On-Grade Edge Insulatio EXT MASTER WI 12 ft 78 ft2 ---_ 0 0 1
15SIab-On-Grade Edge Insulatio MASTER SUITE 18 ft 286 ft2 ____ 0 0 1
16SIab-On-Grade Edge'lnsulatio SITTING ROOM 29 ft 99 ft2 __ 0 .0 1
ROOF
/ Roof, Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Barrel tile 2566 ft2 0 ft2 Medium 0.9 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 2369 ft2 N N
4/12/2017 5:40 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software page 3 of 6
4'
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under Attic(Vented) BED 3 30 177 ft2 0.1 Wood
2 Under Attic(Vented) LAUNDRY 30 72 ft2 0.1 Wood
3 Under Attic(Vented) BATH 2 30 105 ft2 0.1 Wood
4 Under Attic(Vented) WIC BED 2 30 22 ft2 0.1 Wood
5 Under Attic(Vented) BED 2 30 154 ft2 0.1 Wood
6 Under Attic(Vented) BREAKFAST 30 105 ft2 0.1 Wood
7 Under Attic(Vented) KITCHEN 30 220 ft2 0.1 Wood
8 Under Attic(Vented) DINING ROOM 30 152 ft2 0.1 Wood
9 Under Attic(Vented) GREAT ROOM 30 544 ft2 0.1 Wood
10 Under Attic(Vented) FOYER 30 96 ft2 0.1 Wood
11 Under Attic(Vented) MASTER BATH 30 192 ft2 0.1 Wood
12 Under Attic(Vented) TIOLET MASTER 30 22 ft2 0.1 Wood
13 Under Attic(Vented) WIC SML MASTE 30 46 ft2 0.1 Wood
14 Under Attic(Vented) EXT MASTER WI 30 78 ft2 0.1 Wood
15 Under Attic(Vented) MASTER SUITE 30 286 ft2 0.1 Wood
16 Under Attic(Vented) SITTING ROOM 30 99 ft2 0.1 Wood
WALLS
Adjacent In Et In Area R-�tahve Fraction Absor Grntle%9 nrnt Tn Wall TypeSpace Cavity Width Height Sheathing Framing Solar Below
1 S Exterior Concrete Block-Int Insul BED 3 4.1 15 0 10 0 150.0 ft2 0 0 0.5 0
2 S Exterior Concrete Block-Int Insul BATH 2 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0
3 S Exterior Concrete Block-Int InsLNVIC BED 2 4.1 4 0 10 0 40.0 ft2 0 0 0.5 0
4 S Exterior Concrete Block-Int Insul BED.2 4.1 13 6 10 0 135.0 ft2 0 0 0.5 0
5 W Exterior, Concrete Block-Int Insul BED 2 4.1 11 0 10 0 110.0 ft2 0 0 0.5 0
_ 6 S Exterior Concrete Block-Int InsOREAKFAST 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0
_ 7 W Exterior Concrete Block-Int InsBItEAKFAST 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0
8 NW Exterior Concrete Block-Int InsBREAKFAST 4.1 4 0 10 0 40.0 ft2 0 0 0.5 0 .
9 E Exterior Concrete Block-Int InsIANING ROO 4.1 10 11 11 0 120.1 ft2 0 0 0.5 0
10 W Exterior Concrete Block-Int Ins03REAT ROO 4.1 17 0 10 0 170.0 ft2 0 0 0.5 0
11 E Exterior Concrete Block-Int Insul FOYER 4.1 7 3 11 0 79.8 ft2 0 0 0.5 0
12 NE Exterior Concrete Block-Int InsIVASTER BA 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0
_13 E Exterior Concrete Block-Int InsMASTER BA 4.1 8 2 11 0 89.8 ft2 0 0 0.5 0
14 SE Exterior Concrete Block-Int InsMASTER BA 4.1 6 0 10 0 60.0 ft2 0 0 0.5 0
15 N Exterior Concrete Block-Int InsfflOLET MAS 4.1 4 0 10 0 40.0 ft2 0 0 0.5 0
_16 N Exterior Concrete Block-Int InstEXT MASTE 4.1 12 0 10 0 120.0 ft2 0 0 0.5 0
17 N Exterior Concrete Block-Int InsMASTER SUI 4.1 18 0 10 0 180.0 ft2 0 0 0.5 0
18 N Exterior Concrete Block-Int Insi;91TTING RO 4.1 9 0 10 0 90.0 ft2 0 0 0.5 0
19 S Exterior Concrete Block-Int InsiSITTING RO 4.1 9 0 10 0 90.0 ft2 0 0 0.5 0
_20 W Exterior Concrete Block-Int InsiSITTING RO 4.1 11 0 10 0 110.0 ft2 0 0 0.5 0
_21 NE Garage Frame-Wood BED 3 11 20 10 200.0 ft2 0.23 0.75 0
4/12/2017 5:40 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 NE Wood BED 3 None .46 2.6 8 20.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 S 1 Metal Double(Tinted) Yes 0.53 0.24 15.0 ft2 2 ft 0 in 1 ft 0 in None None
2 S 2 Metal Double(Tinted) Yes 0.53 0.24 6.0 ft2 2 ft 0 in 1 ft 0 in None None
3 W 5 Metal Double(Tinted) Yes 0.53 0.24 15.0 ft2 2 ft 0 in 1 ft 0 in None None
4 W 7 Metal Double(Tinted) Yes 0.53 0.24 36.0 ft2 2 ft 0 in 1 ft 0 in None None
5 NW 8 Metal Double(Tinted) Yes 0.53 0.24 18.0 ft2 5 ft 0 in 1 ft 0 in None None
6 E 9 Metal Double(Tinted) Yes 0.53 0.24 23.0 ft2 2 ft 0 in 1 ft 0 in None None
7 W 10 Metal Double(Tinted) Yes 0.53 0.24 64.0 ft2 11 ft 0 in 1 ft 0 in None None
8 E 11 TIM Double(Clear) Yes 0.56 0.23 66.0 ft2 8 ft 0 in 1 ft 0 in None None
9 NE 12 Metal Double(Tinted) Yes 0.53 0.24 6.0 ft2 2 ft 0 in 1 ft 0 in None None
10 E 13 Metal Double(Tinted) Yes 0.53 0.24 6.0 ft2 2 ft 0 in 1 ft 0 in None None
11 SE 14 Metal Double(Tinted) Yes 0.53 0.24 6.0 ft2 2 ft 0 in 1 ft 0 in None None
12 N 15 Metal Double(Tinted) Yes 0.53 0.24 5.0 ft2 2 ft 0 in 1 ft 0 in None None
13 N 17 Metal Double(Tinted) Yes 0.53 0.24 36.0 ft2 2 ft 0 in 1 ft 0 in None None
14 W 20 Metal Double(Tinted) Yes 0.53 0.24 30.0 ft2 2 ft 0 in 1 ft 0 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 530 ft2 384 ft2 64 ft loft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH, ACH 50
1 Wholehouse Proposed ACH(50) .000318 1973.2 108.32 203.72 .2318 5
HEATING SYSTEM
# System Type Subtype - Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.2 42.5 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER:14 42.5 kBtu/hr 1275 cfm 0.75 1 sys#1
4/12/2017 5:40 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
:FORM R405-2014
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— ---Return— Air CFM 25 CFM25 HVAC#
�/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN, RLF Heat Cool
1 Attic 6 300 ft2 Attic 1 ft2 Proposed Qn BED 3 —cfm 94.8 cfm 0.04 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling Jan Feb y 9
Au ep Oct Dec
Nov
Venting Jan Feb �X�Mar Mar �C�Apr May rl Jun rl Jul I A Ma Jun Jul I Aug rj Sep �X�Oct �X�Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours,
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(VVD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
4/12/2017 5:40 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
ENERGY PERFORMANCE LEVEL .(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
9500 POINCIANA CT, FORT PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
w,2; Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1964.70 ft2
b. Frame-Wood,Adjacent R=11.0 200.00 ftZ
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 2370.00 ft2
6. Conditioned floor area(ft2) 2369 b.N/A R= ft2
7. Windows- Description Area c. R= ft2
a. U-Factor: Dbl,U=0.53 266.00 ft2 11.Ducts R ft2
SHGC: SHGC=0.24 a.Sup:Attic,Ret:Attic,AH:BED 3 6 300
b. U-Factor. Dbl,U=0.56 66.00 ft2
SHGC: SHGC=0.23 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 42.5 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 42.5 HSPF:8.20
Area Weighted Average Overhang Depth: 5.090 ft.
Area Weighted Average SHGC: 0.238
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2369.00 ft2EF:0.95
b.N/A R= ft2 b. Conservation features
c.N/A R= ft2
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building -0IE Sx
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise a new EPL Display Card will be completed
based on installed Code compliant
Builder Signature: Date:
Address of New Home: G,SUO ppij aj/� CT City/FL Zip: (-�{�, 1 e f7t OD WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Coriservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/12/2017 5:40 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
Project Summary Job:
Date: Jun 24,2016
;,•,,��,.,,AIR CONDITIONI G,INC. Entire House By: LINDSTROM
N
.._ Lindstrom Air Conditioning
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com
• • •
For: LENNAR
Notes:
Design lffo 6h
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
.Heating Summary Sensible Cooling Equipment Load Sizing
Structure 28478 Btuh Structure 25618 Btuh
Ducts 4247 Btuh Ducts 4879 Btuh
Central vent(75 cfm) 2309 Btuh Central vent (75 cfm) 1237 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load' 35034 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 30148 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3439 Btuh
Ducts 2085 Btuh
Heating Cooling Central vent (75 cfm) 3134 Btuh
Area(ftz) 2369 2369 Equipment latent load 8658 'Btuh
Volume ft') 23693 23693
Air changes/hour 0.32 0.16 Equipment total load 38806 Btuh
Equiv.AVF(cfm) 126 63 Req. total capacity at 0.79 SHR 3.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make LENNOX Make .LENNOX
Trade Trade
Model 14HPX-042 Cond 14HPX-042
AHRI ref Coil CBX25UH-042
AHRI ref
Efficiency 8.2 HSPF Efficiency 14 SEER
Heating input .Sensible cooling 33400 Btuh
Heating output 42500 Btuh @ 47OF Latent cooling 9100 Btuh
Temperature rise 28 OF Total cooling 42500 Btuh
Actual air flow 1400 cfm Actual air flow 1400 cfm
Air flow factor 0.043 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.79
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-Apr-12 17:54:08
A wrightsoft' Right-Suite®Universal 2013 13.0.12 RSU08398 Page 1
ACCA SAPROJECTS ENERGYIA-MANUAL J\LH-2369-MW.rup Calc=MJ8 Front Door faces: N
Righ"o Worksheet Job:
Entire House Date: Jun 24,2016
Lindstrom Air Conditioning By: LINDSTROM
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com
F3
1 Room name Entire House BED 3
2 Exposed wall 225.0 ft 25.0 ft
Room height 10.0 ft 10.0 ft heat/cool
ft
5 Room area 2369.2 ft2 177.8 ftz
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ftZ-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 430 389 1558 990 0 0 0 0
ID-h2om 0.870 n 24.36 2227 5 0 122 111 0 0 0 0
1D-h2om 0.870 n 24.36 22-27 36 0 877 802 0 0 0 0
tE 13A-4ocs 0.143 ne 4.00 2.55 60 54 216 137 0 0 0 0
11 1D-h2om 0.870 ne 24.36 43.19 6 0 146 259 0 0 0 0
13A-4ocs 0.143 a 4.00 Z55 290 195 781 496 0 0 0 0
10B-b 0.750 a 21.00 26.82 66 68 1386 1770 0 0 0 0
1 D-h2om 0.870 a 24.36 44.42 6 4 146 267 0 0 0 0
ID-h2om 0.870 a 24.36 50.97 23 6 560 1172 0 0 0 0
13A-4ocs• 0.143 se 4.00 2.55 60 54 216 137 0 0 0 0
Y--G 1D-h2om 0.870 se 24.36 22.27 6 12 146 134 0 0 0 0
13A-4ocs 0.143 s 4.00 2-55, 615 594 2378 1512 150 135 541 344
GG 1D-h2om 0.870 s 24.36 '2227 6 12 146 134 0 0 0 0
T- ID-h2om 0.870 s 24.36 22.27 15 30 365 334 15 15 365 334
13A-4ocs 0.143 w 4.00 2.55 470 325 1301 827 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 15 4 365 765 0 0 0 0
ID-h2om 0.870 w 24.36 50.97 30 8 731 1529 0 0 0 0
1D-h2om 0.870 w 24.36 51.69 36 8 877 1861 0 0 0 0
1D-h2omd 0.870 w 24.36 22.27 64 128 1559 1426 0 0 0 0
13A-4ocs 0.143 nw 4.00 Z55 40 22 88 56 0 0 0 0
ID-h2om 0.870 nw 24.36 43.19 18 0 438 777 0 0 0 0
126-0bw 0.097 - 2.72 0.85 165 143 388 122 100 100 272 85
D 11DO 0.390 n 10.92 11.31 22 22 240 249 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 2369 2369 2123 2464 178 178 159 185
F 22A-cpm 1.180 n 33.04 0.00 2369 225 7434 0 178 25 826 0
6 c)AED excursion 2925 -80
Envelope loss/gain. 24590 212571 2163 868
12 a) Infiltration 3888 1042 297 80
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 4 920 1 230
Appliances/other 2400 0
Subtotal(lines 6 to 13) 28478 25618 2460 1178
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 28478 25618 2460 1178
15 Duct loads 15% 19% 4247 4879 15% 19% 367 224
Total room load i 1 32725 30497 2826 1402
Air required(cfm) 1400 14001 121 64
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
wrigt�tsoft� 2017-Apr-12 17:54:08
Right-Suite®Universal 2013 13.0.12 RSU08398 Page 1
'��` SAPROJECTS ENERGM-MANUAL J%LH-2369-MW.rup Calc=MJ8 Front Door faces: N
Right-J®Worksheet Job:
Linw Entire House Date: Jun 24,2016
Lindstrom Air Conditioning By: LINDSTROM
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com
1 Room name LAUNDRY WIC BED 2
2 Exposed wall 6.5 ft 4.0 ft
3 Room height 10.0 ft heat/tool 10.0 ft heat/cool
4 Room dimensions 6.5 x 11.0 ft 5.5 x 4.0 ft
5 Room area 71.5 ft2 22.0 ftz
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ftz°F) (Btu ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 %r13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
-�G 1D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0
1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0
11 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0
13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
10B-b 0.750 a 21.00 26.82 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 44.42 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 50.97 0 0 0 0 0 0 0 0
W 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
�G 1D-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0
1(V 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 40 40 160 102
1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
1D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 51.69 0 0 0 0 0 0 0 0
ID-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0
1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0
12B-Obw 0.097 - 2.72 0.85 65 43 117 37 0 0 0 0
D 11DO 0.390 n 10.92 11.31 22 22 240 249 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 72 72 64 74 22 22 20 23
F 22A-cpm 1.180 n 33.04 0.00 72 7 215 0 22 4 132 0
6 c)AED excursion -23 -9
Envelope loss/gain 636 337 312 115
12 a) Infiltration 0 0 79 21
b) Room ventilation 10 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 636 337 391 137
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 636 337 391 137
15 Duct loads 15% 19% 95 64 15% 19. 58 26
Total room load 731 401 450 163
Air required(cfm) 31 18 19 7
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
wrightsoft- 2017-Apr-12 17:54:08
Right-Suite®Universal 2013 13.0.12 RSU06398'C Page 2
�` SAPROJECTS ENERGYIN-MANUAL J%LH-2369-M W.rup Calc=MJB Front Door faces: N
Right-JO Worksheet Job:
Entire House Date: Jun 24,2016
By: LINDSTROM
- Lindstrom Air Conditioning
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com
1 Room name BED 2 BREAKFAST
2 Exposed wall 24.5 ft 18.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 11.0 x 14.0 ft 11.0 x 9.5 ft
5 Room area 154.0 ftz 104.5 ftz
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ft2L-°F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
. 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
1D-h2om 0.870 n 24.36 2227 0 0 0 0 0 0 0 0
1D-h2om 0.870 n 24.36 2227 0 0 0 0 0 0 0 0
IN 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0
11 L-G 1 D-h2om 0870 ne 24.36 43.19 0 0 0 0 0 0 0 0
13A-4ocs 0. a 4.GO 255 0 0 0 0 0 0 0 0
10B-b 0.750 750 a 21.00 26.82 0 0 0 0 0 0 0 0
ID-h2om 0.870 a 24.36 44.42 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 50.97 0 0 0 0 0 0 0 0
13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
t-G 1D-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0
yV 13A-4ocs 0.143 s 4.00 2.55 135 135 541 344 60 60 240 153
II_GG 1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
1D-h2om 0.870 s 24.36 22-27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2-55 110 95 380 242 80 44 176 112
1 D-h2om 0.870 w 24.36 50.97 15 2 365 765 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 q 0 0 0 0 0 0 0
1D-h2om 0.870 w 24.36 51.69 0 0 0 0 36 4 877 1861
1D-h2omd 0.870 w 24.36 2227 0 0 0 0 0 0 0 0
13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 40 22 88 56
t-G 1D-h2om 0.870 rw 24.36 43.19 0 0 0 0 18 0 438 777
12B-Obw 0.097 - 2-72 0.85 0 0 0 0 0 0 0 0
D 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 154 154 138 160 105 105 94 109
F 22A-cpm 1.180 n 33.04 0.00 154 25 809 0 105 18 595 0
6 c)AED excursion 252 970
Envelope loss/gain 2234 1762 2508 4038
12 a) Infiltration 485 130 356 95
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 1 230 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2719 2122 2864 4133
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2719 2122 2864 4133
15 Duct loads 15% 19% 405 404 15% 19% 427 787
Total room load 3124 2526 3292 4921
Air required(cfm) 134 116 141 226
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft' 2017-Apr-12 17:54:08
Right-Suite®Universal 2013 13.0.12 RSU08398 Page 3
ACCP" S:%PROJECTS ENERGYIA-MANUAL J1LH-2369-MW.rup Calc=MJ8 Front Door faces: N
Right-M Worksheet Job:
Entire House Date: Jun 24,2016
_ By: LINDSTROM
Lindstrom Air Conditioning
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064-Web:www.lindstromair.com
1 Room name KITCHEN GREAT ROOM
2 Exposed wall 0 ft 17.0 ft
3 Room height 10.0 ft heaticool 10.0 ft heat/cool
4 Room dimensions 9.8 x 20.0 ft 17.0 x 32.0 ft
5 Room area 195.0 ftz 544.0 ft'
Ty Construction U-value Or HTM Area ffl Load Area (ft� Load
number (Btuh/fV °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
. 6 1(U 13A-4ocs 0.143 n 4.00 Z55 0 0 0 0 0 0 0 0
---�G 1 D-h2om 0.870 n 24.36 2227 0 0 0 0 0 0 0 0
1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0
11 ID-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0
13A-4ocs 0.143 a 4.00 255 0 0 0 0 0 0 0 0
10B-b 0.750 a 21.00 26.82 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 44.42 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 50.97 0 0 0 0 0 0 0 0
1(V 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
L .G ID-h2om 0.870 se 24.36 2227 0 0 0 0 0 0 0 0
13A-4ocs 0.143 s 4.00 2-55 0 0 0 0 0 0 0 0
1D-112om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 170 106 424 270
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 51.69 0 0 0 0 0 0 .0 0
ID-h2omd 0.870 w 24.36 22.27 0 0 0 0 64 64 1559 1426
13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0
1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0
12B-0bw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0
D 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 195 195 175 203 544 544 487 566
F 22A-cpm 1.180 n 33.04 0.00 195 0 0 0 544 17 562 0
6 c)AED excursion -1651 1932
Envelope loss/gain. 175 38 3033 4193
12 a) Infiltration 0 0 336 90
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 2400 0
Subtotal(lines 6 to 13) 175 2438 3369 4283
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 175 2438 3369 4283
151 Ductloads 15% 19% 26 464 15% 19% 502 816
Total room load 201 2903 3871 5098
Air required(cfm) 9 133 166 234
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
- wrightsoft- Right-Suite®Universal 2013 13.0.12 RSU08396 2017-Apr-12 17:54 Page 4e 4
AC Ck S:\PROJECTS ENERGYIA-MANUAL J\LH-2369-MW.rup Calc=MJ8 Front Door faces: N
Right-J®Worksheet Job:
Entire House Date: Jun 24,2016
By: LINDSTROM
Lindstrom Air Conditioning
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromaircom
1 Room name MASTER BATH TIOLET MASTER
2 Exposed wall 26.0 ft 4.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 16.0 x 12.0 ft 5.5 x 4.0 ft
5 Room area 192.0 ftz 220 ft2
Ty I Construction U-value Or HTM Area (ft� Load AreaLoad
number (Btuh/ftf°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimet r (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Irl
13A•4ocs 0.143 n 4.00 2.55 0 0 0 0 40 35 140 89
ID-h2om 0.870 n 24.36 22.27 0 0 0 0 5 0 122 111
1D-h2om 0.870 n 24.36 2227 0 0 0 0 0 0 0 0
�(�/ 13A•4ocs 0.143 ne 4.00 2.55 60 54 216 137 0 0 0 0
11 '-G 1 D-h2om 0.870 ne 24.36 43.19 6 0 146 259 0 0 0 0
13A-4ocs 0.143 a 4.00 255 90 84 336 214 0 0 0 0
108-b 0.750 a 21.00 26.82 0 0 0 0 0 0 0 0
iD-h2om 0.870 a 24.36 44.42 6 2 146 267 0 0 0 0
1 D-h2om 0.870 a 24.36 50.97 0 0 0 0 0 0 0 0
13A-4ocs 0.143 se 4.00 255 60 54 216 137 0 0 0 0
1D-h2om 0.870 se 24.36 2227 6 6 146 134 0 0 0 0
13A-4ocs 0.143 s 4.00 255 0 0 0 0 0 0 0 0
1D-h2om 0.870 s 24.36 2227 0 0 0 0 0 0 0 0
1D-112om 0.870 s 24.36 22-27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 51.69 0 0 0 0 0 0 0 0
ID-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0
1N 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0
L a 1D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0
12B-Obw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0
D 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 192 192 172 200 22 22 20 23
F 22A-cpm 1.180 n 33.04 0.00 192 26 859 0 22 4 132 0
6 c)AED excursion -92 -15
Envelope loss/gain 2238 1255 414 208
12 a) Infiltration 416 111 79 21
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2654 1367 493 229
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2654 1367 493 229
15 Duct loads 15% 19% 396 260 15% 19% 74 44
Total room load 3050 1627 566 273
Air required(cfm) 130 751 T
24 13
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
wrightsoft- Right-Suite®Universal 2013 13.0.12 RSU08398 2017-Apr-12 17:54:08
Page 5
'�� S:IPROJECTS ENERGYIA-MANUAL J1LH-2369-MW.rup Calc=MJ8 Front Door faces: N
Right-J®Worksheet Job:
Entire House Date: Jun 24,2016
Lindstrom Air Conditioning By: LINDSTROM
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com
1 Room name WIC SML MASTER EXr MASTER WIC
2 Exposed wall 0 ft 12.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 6.5 x 7.0 ft 12.0 x 6.5 ft
5 Room area 45.5 ft2 78.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 120 120 480 305
1D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0
1 D-h2om 0.870 n 24.36 2227 0 0 0 0 0 0 0 0
w 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0
11 Y--G 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0
13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
10B-b 0.750 a 21.00 26.82 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 44.42 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 50.97 0 0 0 0 0 0 0 0
lIV 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
-G ID-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
1 D-h2om 0.870 s 24.36 2227 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 51.69 0 0 0 0 0 0 0 0
1D-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0
1(V 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0
V CG 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0
R 12B-Obw 0.097 - Z72 0.85 0 0 0 0 0 0 0 0
`D 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 46 46 41 47 78 78 70 81
F 22A-cpm 1.180 n 33.04 0.00 46 0 0 0 78 12 396 0
6 c)A ED excursion -3 -28
Envelope loss/gain 41 44 947 358
12 a) Infiltration 0 0 237 64
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 41 44 1184 422
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 41 44 1184 422
15 Duct loads 150/0 19% 6 8 15% 19% 177 80
Total room load 47 53 1 1361 502
Air required(cfm) 2 2 158 23
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
+�- wrightsoft� 2017-Apr-12 17:54:08
Right-Suite®Universal 2013 13.0.12 RSU08398 Page 6
ACC` SAPROJECTS ENERGYIA-MANUAL J\1-1-1-2369-MW.rup Calc=MJ8 Front Door faces: N
Righ"o Worksheet Job:
Entire House Date: Jun 24,2016
Lindstrom Air Conditioning By: LINDSTROM
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromaircom
1 Room name MASTER SUITE SITTING ROOM
2 Exposed wall 18.0 ft 29.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 13.0 x 22.0 ft 9.0 x 11.0 ft
5 Room area 286.0 ft2 99.0 ft'
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ff-°F) (Btuh/ft� or perimeter (ft) (Stuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2-55 180 144 577 367 90 90 360 229
1D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0
1D-h2om 0.870 n 24.36 22.27 36 0 877 802 0 0 0 0
w 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0
11 �--G ID-h2om 0.870 ne 24.36 43.19 0. 0 0 0 0 0 0 0
1 0. a 4.00 255 0 0 0 0 0 0 0 0
1013-b 0B-b 0.750750 a 21.00 26.82 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 44.42 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 50.97 0 0 0 0 0 0 0 0
VII 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
--G ID-h2om 0.870 se 24.36 22-27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 s- 4.00 2.55 0 0 0 0 90 90 360 229
ID-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
1 D-h2om. 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 255 0 0 0 0 110 80 320 204
ID-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 30 4 731 1529
1D-h2om 0.870 w 24.36 51.69 0 0 0 0 0 0 0 0
1 D-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0
11V 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0
--G 1D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0
126-0bw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0
D 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 286 286 266 297 99 99 89 103
F 22A-cpm 1.180 n 33.04 0.00 286 18 595 0 99 29 958 0
i
6 c)AED excursion -128 585
Envelope loss/gain 2305 1338 2819 2879
12 a) Infiltration 356 95 574 154
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2661 1893 3393 3033
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2661 1893 3393 3033
15 DUCt IoadS1 15% 19% 3971 361 15% 19% 506 578
Total room load 3057 22-14 38981 3610
Air required(cfm) 131 103 167 166
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft- Ri ht-Suite®Universal 2013 13.0.12 RSU08398 2017-Apr-12 17:54e 7
'�C` SAPROJECTS ENERGM-MANUAL J%LH-2369-MW.rup Calc=MJ8 Front Door faces: N Page 7
Right-J®Worksheet Job:
' " Entire House Date: Jun 24,2016
_._ Lindstrom Air Conditioning By: LINDSTROM
3581 W MCNAB RD,POMPANO BEACH,FL 33059 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com
1 Room name PANTRY DINING ROOM
2 Exposed wall 0 ft 20.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 5.0 x 5.0 ft 20.0 x 12.4 ft
5 Room area 25.0 ft' 248.0 ft'
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ft;°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
_ 1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0
1 D-h2om 0.870 n 24.36 22.27. 0 0 0 0 0 0 0 0
13A-4ocs 0.143 ne 4.00 255 0 0 0 0 0 0 0 0
11 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0
13A-4ocs 0.143 a 4.00 255 0 0 0 0 200 111 444 283
106-b 0.750 a 21.00 26.82 0 0 0 0 66 34 1386 1770
1 D-h2om 0.870 a 24.36 44.42 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 50.97 0 0 0 0 23 3 560 1172
1(V 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
_,G 1 D-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0
13AAocs 0.143 s 4.00 255 0 0 0 0 0 0 0 0
1D-h2om 0.870 s 24.36 2227 0 0 0 0 0 0 0 0
1D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
ID-h2cm 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
ID-h2om 0.870 w 24.36 51.69 0 0 0 0 0 0 0 0
1D-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 nw 4.00 255 0 0 0 0 0 0 0 0
t-G 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0
12B-0bw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0
D 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 25 25 22 26 248 248 222 258
F 22A-cpm 1.180 n 33.04 0.00 25 0 0 0 248 20 661 0
6 c)AED excursion -2 -227
Envelope loss/gain 22 24 3274 3256
12 a) Infiltration 0 0 396 106
b) Room ventilation 0 0 01 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 22 24 3669 3362
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 22 24 3669 3362
15 Duct loads 15% 19% 3 5 15% 19% 547 640
Total room load 26 291 T 4217 4002
Air required(cfm) 1 1 180 184
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft- 2017-Apr-12 17:54:08
Right-Suite®Universal 2013 13.0.12 RSU08398 Page 8
'CO` SAPROJECTS ENERGYIA-MANUAL J%LH-2369-MW.rup Calc=MJ8 Front Door faces: N
Right-J®Worksheet Job:
Entire House Date: Jun 24,2016
Lindstrom Air Conditioning By: LINDSTROM
3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com
1 Room name BATH 2 BATH 2 SINKS
2 Exposed wall 14.0 ft 7.0 ft
3 Room height 10.0 ft heaYcool 10.0 ft heat/cool
4 Room dimensions 5.0 x 10.0 ft 5.5 x 10.0 ft
5 Room area 50.0.ftz 55.0 ft2
Ty Construction U-value Or HTM Area (ft� Load Area (112) Load
number (Btuhlftz°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
ID-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0
ID-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0
11 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0
• 13A-4ocs 0. a .00 2. 0 0 0 0 0 0 0 0
10B-b 0.750 750 a 21.00 26.8282 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 44.42 0 0 0 0 0 0 0 0
1 D-h2om 0.870 a 24.36 50.97 0 0 0 0 0 0 0 0
13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
t-G 1D-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0
r -G 13A-4ocs 0.143 s 4.00 2.55 70 67 268 171 70 67 268 171
1D-h2om 0.870 s 24.36 2227 3 3 73 67 3 3 73 67
ID-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0
13A-4ocs 0.143 w 4.00 255 0 0 0 0 0 0 0 0
1D-h2cm 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1 D-h2om 0.870 w 24.36 50.97 0 0 0 0 0 0 0 0
1D-h2om 0.870 w 24.36 51.69 0 0 0 0 0 0 0 0
1D-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0
13AAocs 0.143 nw 4.00 255 0 0 0 0 0 0 0 0
t-G ID-h2om 0.870 nw 24.36. 43.19 0 0 0 0 0 0 0 0
12B-0bw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0
D 11DO 0.390 n 10.92 11.31 0 0 0 0 0 0 0 0
C 16D-30td 0.032 n 0.90 1.04 50 50 45 52 55 55 49 57
F 22A-cpm 1.180 n 33.04 0.00 50 14 463 0 55 7 231 0
6 c)AED excursion -21 -21
Envelope loss/gain 849 . 269 622 274
12 a) Infiltration 139 37 139 37
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0. 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 987 306 760 311
"s
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 987 306 760 311
15 Ductloads 15% 19% 147 58 15% 19% 113 59
Total room load 1134 364 874 370
Air required(cfm) 49 17 37 17
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
WPi htsOfC 2017-Apr-1217:54:08
9 Right-Suite®Universal 2013 13.0.12 RSUD8398 Page 9
'`( C11'` SAPROJECTS ENERGYIA-MANUAL J1LH-2369-MW.rup Calc=MJ8 Front Door faces: N