HomeMy WebLinkAboutCertification for Design Load Compliancetc,2
„N� _ Lid 'J Planning & Development Services Department
® Building & Code Regulations Division
0
- - 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Complianri-
-
Project Name: Meadowood
Project Address: 9500 Poincianna Ct
Permit #: Occupancy Type: R-3 Construction Type: VB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 170 mph 132 ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height 15'-0" ft Roof Pitch: 5 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -35.0 Zone 2: -61 Zone 3: -90.2 Zone 4: -41.5 Zone 5: -51.3 Garage: -35.2
7. Design Loads: Floor: 40 PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: 60 PSF
Dock: NSA PSF Deck: 60 PSF Stairs: NSA PSF Fence: NSA PSF Railings: 50 PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
Co t I Iso certify that structural elements depicted on these plans provide adequate resistance to the design
E.. Stephen R. Walsh P.E. #33915
®�
® C' ��y• A` Print Name Cert # & Co. Cert Auth.
Co
0 3915V'• Walsh Engineering, Inc.
lgnature, Va te, a eal 3200 N. Federal Highway„Suite 226 Boca Raton FI 33431
G
es�, �ti/ , R I ®Q;•'��� Company Name & Address