HomeMy WebLinkAboutProduct Approval (5) 1 B lop
• •
B 0 ® + I I _
fil
BCIS Home Log In i User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications FBC Staff I BCIS Site Map Links I Search
Florida
1 �' :.1 Product Approval
�° USER:Public User
de `.ro�i
p� Product Approval Menu>Product or Application Search>Application List>Application Detail
• FL# FL15088-R1
Application Type Revision
Code Version 2014
Application Status Approved
S
Comments
Archived U
w
Product Manufacturer Global Protection Products, LLC.
Address/Phone/Email 4800 SW 51st Street#100
Davie, FL 33314
(954) 689-7545
tim.robinson@gppent.com
Authorized Signature y Tim Robinson
tim.robinson@gppent.com
Technical Representative Tim Robinson
Address/Phone/Email 4800 SW 51st Street
Davie, FL 33314-5537
(954) 689-7545
tim.robinson@gppent.com
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Fabric Storm Panel
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
N6 Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Walter A.Tillit Jr., P.E.
the Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
_J = Quality Assurance Contract Expiration Date 12/31/2017
Validated By John W. Knezevich, PE
u Validation Checklist- Hardcopy Received
Certificate of Independence FL15088 R1 COI GLOBAL PROTECTION PRODUCTS C.I. DRWG.15-
020.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM E1886 2005
ASTM E1996 2005
ASTM E330 2002
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/24/2015
Date Validated 04/27/2015
Date Pending FBC Approval 05/03/2015
Date Approved 06/23/2015
Summary of Products
FL# Model,Number or Name Description
15088.1 GPP FABRIC SHUTTER-SERIES 2000 Coated Polyethylene Fabric Panels retained by tracks or
direct mounted to provide hurricane protection.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15088 R1 II GLOBAL PROTECTION PRODUCTS DRWG.15-
Approved for use outside HVHZ:Yes 020.pdf
Impact Resistant:Yes Verified By: Walter A.Tillit Jr., P.E. PE-44167
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Large Missile Impact resistant with a Maximum span Evaluation Reports
of 12'-7" @ 60 p.s.f. See sheet 13 of installation drawings for FL15088 R1 AE GLOBAL PROTECTION
type and substrate permissible with maximum span as well PRODUCTS P.E.R. DRWG.15-020.pdf
as other spans and pressures, based on mounting types and Created by Independent Third Party: Yes
substrates.
sack Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement:: Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here. I
Product Approval Accepts:
r1IF51 RN
eCheik �-�
Credit Card
Safe
�T 7i�L r�-,
TILLIT TESTING & ENGINEERING COMPANY
WALTER A.TTLLTT,JR.,P.E. tilteco@aol.com
FL .E.License No 4417
PRODUCT EVALUATION REPORT FLEBP License No.00 6719
REPORT NO.: 15-0319.01
DATE: March 19, 2015
PRODUCT CATEGORY: Shutters
PRODUCT SUB-CATEGORY: Fabric Storm Panels
PRODUCT NAME: GPP Fabric Shutter-Series 2000
MANUFACTURER: Global Protection Products, LLC
4800 S.W. 51 Street
Davie, Florida 33314
1. PURPOSE OF EVALUATION:
This is a Product Evaluation Report issued by Walter A. Tillit, Jr., P.E. (System
iD # 1906) to the Global Protection Products, LLC , Rule Chapter No.
61G20-3, Method 1D of the Florida Department of Business and
Professional Regulation.
This product is being issued an Evaluation Report as described herein, and has
been verified for compliance in accordance with the 2014 fifth edition of the
Florida Building Code, and to verify that the product is for the purpose intended
at least equivalent to that required by the Code.
This Product Evaluation Report shall be subject to review and revision in case of
a Building Code change that may affect its limitations and conditions.
.2. EVIDENCE SUBMITTED:
2.1. PRODUCT EVALUATION DOCUMENT (P,E.D.):
Drawing No. 15-020 (revises No. 11-212), titled "GPP Fabric Shutter-Series
2000", sheets 1 thru 15 of 15 prepared by Tilteco, Inc.;, sjgned and sealed by
Walter A.Tillit, Jr., P.E.; dated 03112/2015. This drawl ig s� q�ral part of this
Evaluation Report.
6355 N.W. 36th Street, Suite 305, Miami, Florida 33166 -Phone: (305) yi=j'530 -Fax: (305) 871-1531
. PRODUCT EVALUATION REPORT NO. 15-0319.01 2
2.2. TEST REPORTS:
Large missile impact load tests were performed under ASTM E-1886 and ASTM
E-1996 standards as per section 1609.1.2 of the Florida Building Code. Uniform
static loads as per Section 1710.5.2, per ASTM E-330. Test reports prepared by
American Testing Lab of South Florida, report No. 0904.01-09, dated 02/17/10,
witnessed, signed and sealed by Edmundo Largaespada, P.E.
Tensile test report No. 91M-865/9KM-1127 by QC Metallurgical, Inc., dated
November 30, 2009, signed and sealed by Frank Grate, P.E.
Fire Test Report No. 95138.01-106-18 by Architectural Testing Inc, dated
10/15109, signed and sealed by Joseph A. Reed, P.E.
2.3. STRUCTURAL ENGINEERING CALCULATIONS:
On GPP Fabric Shutter-Series 2000 for maximum panel length vs. design wind
load, as well as maximum anchor spacing vs. design wind load and panel length
based on rational and comparative analysis, and in accordance with section 1604
of the Florida Building Code. Calculations prepared by Tilteco, Inc., dated
09/03/09, signed and sealed by Walter A. Tillit, Jr., P.E.
3. MISSILE IMPACT RESISTANCE:
Large missile impact under section 1609.1.2 of the Florida Building Code, as per
ASTM E-1996 corresponding to missile type D (basic protection).
4. WIND LOADS RESISTANCE:
GPP Fabric Shutter-Series 2000 has been verified to sustain wind pressures.
Maximum panel length shall be as indicated on sheet 13 of 15 of Product
Evaluation Document ) 9,(P.E.D.), drawing No. 15-020. Maximum Anchor Spacing
(
shall be as indicated on sheets 14 and 15 of 15, of Product Evaluation Document
(P.E.D.), drawing No. 15-020. GPP Fabric Shutter-Series 2000 has been verified
for code compliance to work as a non-porous storm shutter assembly, as per
section 3.2.8 of ASTM E-1996.
5. INSTALLATION:
Installation shall be performed strictly in accordance with details indicated on
sheets 4 thru 12 of 15, of Product Evaluation Document (P.E.D.), drawing No.
15-020. Minimum separation to glass shall be9�p%IhVed on sheet 13 of 15, of
Product Evaluation Document (P.E.D.), drawjftNo.
r
HMO"
PRODUCT EVALUATION REPORT NO. 15-031%01 3
6. MATERIAL CHARACTERISTICS AND SPECIFICATIONS:
Shall be strictly in accordance with General Notes and Components indicated on
sheets 1, 2 and 3 of 15, of Product Evaluation Document (P.E.D.), drawing No.
15-020.
Anchor specifications shall be as indicated on sheets 2, 14 and 15 of 15, of
Product Evaluation Document(P.E.D.), drawing No. 15-020.
7. LIMITATIONS AND CONDITIONS OF USE:
7.1. Shall be strictly in compliance with General Notes No. 1, 5 thru 12, indicated
on sheet 1 of 15 of Product Evaluation Document (P.E.D.), drawing No. 15-020
prepared by Tilteco, Inc. and signed and sealed by Walter A. Tillit, Jr., P.E.
7.2. Product shall not be installed within HIGH VELOCITY HURRICANE ZONES
as defined on section 1620.2 of the Florida Building Code.
7.3. Product shall only be installed into poured concrete, grout filled concrete
block, hollow concrete block, steel and wood frame structures.
Product Evaluation Report prepared by Walter A. Tillit, Jr., P.E. (Florida License
No. 44167), President of Tilteco, Inc. (Florida EB-0006719).
No, 4 `R
.gam 0e �
ev109r;aria&'va��k -