Loading...
HomeMy WebLinkAboutProduct Approval (5) 1 B lop • • B 0 ® + I I _ fil BCIS Home Log In i User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications FBC Staff I BCIS Site Map Links I Search Florida 1 �' :.1 Product Approval �° USER:Public User de `.ro�i p� Product Approval Menu>Product or Application Search>Application List>Application Detail • FL# FL15088-R1 Application Type Revision Code Version 2014 Application Status Approved S Comments Archived U w Product Manufacturer Global Protection Products, LLC. Address/Phone/Email 4800 SW 51st Street#100 Davie, FL 33314 (954) 689-7545 tim.robinson@gppent.com Authorized Signature y Tim Robinson tim.robinson@gppent.com Technical Representative Tim Robinson Address/Phone/Email 4800 SW 51st Street Davie, FL 33314-5537 (954) 689-7545 tim.robinson@gppent.com Quality Assurance Representative Address/Phone/Email Category Shutters Subcategory Fabric Storm Panel Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer N6 Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Walter A.Tillit Jr., P.E. the Evaluation Report Florida License PE-44167 Quality Assurance Entity National Accreditation and Management Institute _J = Quality Assurance Contract Expiration Date 12/31/2017 Validated By John W. Knezevich, PE u Validation Checklist- Hardcopy Received Certificate of Independence FL15088 R1 COI GLOBAL PROTECTION PRODUCTS C.I. DRWG.15- 020.pdf Referenced Standard and Year(of Standard) Standard Year ASTM E1886 2005 ASTM E1996 2005 ASTM E330 2002 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/24/2015 Date Validated 04/27/2015 Date Pending FBC Approval 05/03/2015 Date Approved 06/23/2015 Summary of Products FL# Model,Number or Name Description 15088.1 GPP FABRIC SHUTTER-SERIES 2000 Coated Polyethylene Fabric Panels retained by tracks or direct mounted to provide hurricane protection. Limits of Use Installation Instructions Approved for use in HVHZ: No FL15088 R1 II GLOBAL PROTECTION PRODUCTS DRWG.15- Approved for use outside HVHZ:Yes 020.pdf Impact Resistant:Yes Verified By: Walter A.Tillit Jr., P.E. PE-44167 Design Pressure: N/A Created by Independent Third Party: Yes Other: Large Missile Impact resistant with a Maximum span Evaluation Reports of 12'-7" @ 60 p.s.f. See sheet 13 of installation drawings for FL15088 R1 AE GLOBAL PROTECTION type and substrate permissible with maximum span as well PRODUCTS P.E.R. DRWG.15-020.pdf as other spans and pressures, based on mounting types and Created by Independent Third Party: Yes substrates. sack Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement:: Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. I Product Approval Accepts: r1IF51 RN eCheik �-� Credit Card Safe �T 7i�L r�-, TILLIT TESTING & ENGINEERING COMPANY WALTER A.TTLLTT,JR.,P.E. tilteco@aol.com FL .E.License No 4417 PRODUCT EVALUATION REPORT FLEBP License No.00 6719 REPORT NO.: 15-0319.01 DATE: March 19, 2015 PRODUCT CATEGORY: Shutters PRODUCT SUB-CATEGORY: Fabric Storm Panels PRODUCT NAME: GPP Fabric Shutter-Series 2000 MANUFACTURER: Global Protection Products, LLC 4800 S.W. 51 Street Davie, Florida 33314 1. PURPOSE OF EVALUATION: This is a Product Evaluation Report issued by Walter A. Tillit, Jr., P.E. (System iD # 1906) to the Global Protection Products, LLC , Rule Chapter No. 61G20-3, Method 1D of the Florida Department of Business and Professional Regulation. This product is being issued an Evaluation Report as described herein, and has been verified for compliance in accordance with the 2014 fifth edition of the Florida Building Code, and to verify that the product is for the purpose intended at least equivalent to that required by the Code. This Product Evaluation Report shall be subject to review and revision in case of a Building Code change that may affect its limitations and conditions. .2. EVIDENCE SUBMITTED: 2.1. PRODUCT EVALUATION DOCUMENT (P,E.D.): Drawing No. 15-020 (revises No. 11-212), titled "GPP Fabric Shutter-Series 2000", sheets 1 thru 15 of 15 prepared by Tilteco, Inc.;, sjgned and sealed by Walter A.Tillit, Jr., P.E.; dated 03112/2015. This drawl ig s� q�ral part of this Evaluation Report. 6355 N.W. 36th Street, Suite 305, Miami, Florida 33166 -Phone: (305) yi=j'530 -Fax: (305) 871-1531 . PRODUCT EVALUATION REPORT NO. 15-0319.01 2 2.2. TEST REPORTS: Large missile impact load tests were performed under ASTM E-1886 and ASTM E-1996 standards as per section 1609.1.2 of the Florida Building Code. Uniform static loads as per Section 1710.5.2, per ASTM E-330. Test reports prepared by American Testing Lab of South Florida, report No. 0904.01-09, dated 02/17/10, witnessed, signed and sealed by Edmundo Largaespada, P.E. Tensile test report No. 91M-865/9KM-1127 by QC Metallurgical, Inc., dated November 30, 2009, signed and sealed by Frank Grate, P.E. Fire Test Report No. 95138.01-106-18 by Architectural Testing Inc, dated 10/15109, signed and sealed by Joseph A. Reed, P.E. 2.3. STRUCTURAL ENGINEERING CALCULATIONS: On GPP Fabric Shutter-Series 2000 for maximum panel length vs. design wind load, as well as maximum anchor spacing vs. design wind load and panel length based on rational and comparative analysis, and in accordance with section 1604 of the Florida Building Code. Calculations prepared by Tilteco, Inc., dated 09/03/09, signed and sealed by Walter A. Tillit, Jr., P.E. 3. MISSILE IMPACT RESISTANCE: Large missile impact under section 1609.1.2 of the Florida Building Code, as per ASTM E-1996 corresponding to missile type D (basic protection). 4. WIND LOADS RESISTANCE: GPP Fabric Shutter-Series 2000 has been verified to sustain wind pressures. Maximum panel length shall be as indicated on sheet 13 of 15 of Product Evaluation Document ) 9,(P.E.D.), drawing No. 15-020. Maximum Anchor Spacing ( shall be as indicated on sheets 14 and 15 of 15, of Product Evaluation Document (P.E.D.), drawing No. 15-020. GPP Fabric Shutter-Series 2000 has been verified for code compliance to work as a non-porous storm shutter assembly, as per section 3.2.8 of ASTM E-1996. 5. INSTALLATION: Installation shall be performed strictly in accordance with details indicated on sheets 4 thru 12 of 15, of Product Evaluation Document (P.E.D.), drawing No. 15-020. Minimum separation to glass shall be9�p%IhVed on sheet 13 of 15, of Product Evaluation Document (P.E.D.), drawjftNo. r HMO" PRODUCT EVALUATION REPORT NO. 15-031%01 3 6. MATERIAL CHARACTERISTICS AND SPECIFICATIONS: Shall be strictly in accordance with General Notes and Components indicated on sheets 1, 2 and 3 of 15, of Product Evaluation Document (P.E.D.), drawing No. 15-020. Anchor specifications shall be as indicated on sheets 2, 14 and 15 of 15, of Product Evaluation Document(P.E.D.), drawing No. 15-020. 7. LIMITATIONS AND CONDITIONS OF USE: 7.1. Shall be strictly in compliance with General Notes No. 1, 5 thru 12, indicated on sheet 1 of 15 of Product Evaluation Document (P.E.D.), drawing No. 15-020 prepared by Tilteco, Inc. and signed and sealed by Walter A. Tillit, Jr., P.E. 7.2. Product shall not be installed within HIGH VELOCITY HURRICANE ZONES as defined on section 1620.2 of the Florida Building Code. 7.3. Product shall only be installed into poured concrete, grout filled concrete block, hollow concrete block, steel and wood frame structures. Product Evaluation Report prepared by Walter A. Tillit, Jr., P.E. (Florida License No. 44167), President of Tilteco, Inc. (Florida EB-0006719). No, 4 `R .gam 0e � ev109r;aria&'va��k -