HomeMy WebLinkAboutEngineering PlansCONNECTOR SCHEDULE
ARCHITECT
TRUSS NO.
BEARING
POINT(S)
TRUSS ACTUAL
UPLIFT ( GROUPED,
WORST CASE)
SIMPSON
CONNECTOR(S)
CONNECTOR(S)
UPLIFT DESIGN
FASTENERS
A-A3
1ST BRG
679#
(1) HETA 20
1810# ;
9-10d x 1-1/2"
2ND BRG
HANGER BY TRUSS COMPANY
A4-B
EACH
1190#
(1) HETA 20
1810#
9-10d x 1-1/2"
B1-B2
1ST BRG
HANGER BY TRUSS COMPANY
2ND BRG
1236#
(1) HETA20
1810#
9-10d x 1-1/2"
B3-B6
1ST BRG
HANGER BY TRUSS COMPANY
2ND BRG
1198#
(1) HETA 20
1810#
9-10d x 1-1/2"
C-C1
EACH
1165#
(1)HETA 20
1810#
9-10dx1-1/2"
C2-D1
EACH
3088#
(2)HETA 20
(1) LGT2
2500#
2150#
12-16d
16-16d & 7 1/4" x 2"
1/4" TITENS
D2-G2
EACH
1597#
(1) HETA 20
1810#
9-10d x 1-1/2"
GRA1-GRB
1ST BRG
2577#
(2) HETA 20
(1) LGT2
2500#
2150#
12-16d
16-16d & 7 1W' x 2"
1/4" TITENS
2ND BRG
HANGER BY TRUSS COMPANY
GRID
EACH
3793#
(2) HETA 20
(1) LGT2
2500#
2150#
12-16d
16-16d & 7 1/4" x 2"
1/4" TITENS
GRF
EACH
2286#
(2) HETA 20
2500#
12-16d x 1-1/2"
GRG
EACH
2620#
(2) HETA 20
(1) LGT2
2500#
2150#
12-16d
16-16d & 7 1/4" x 2"
1/4" TITENS
GRP
EACH
4840#
(1) FGTR
5000#
18 SIDS 1/4"x3" &
2 1/2"x5" TITEN/ 10-10d
& 4 1/4" X 2 1/4" TITEN
GRY
EACH
2620#
(2) HETA 20
(1) LGT2
2500#
2150#
12-16d
16-16d & 7 1/4" x 2"
1/4" TITENS
GRZ
1ST BRG
3182#
(2)HETA 20
(1) LGT2
2500#
2150#
12-16d
16-16d & 7 1/4" x 2"
1/4" TITENS
2ND BRG
2248#
(2) HETA 20
2500#
12-16d x 1-1/2"
KING JACKS
1ST BRG
743#
(1) HETA 20
1810#
9-10d x 1-1/2"
2ND BRG
591#
(1) MTS 16
1000#
14-10d x 1-1/2"
HIP JACKS
1ST BRG
157# (1) HETA 20 1810# 9-10d x 1-1/2"
NAILED PER TRUSS COMPANY
2ND BRG
VALLEY TR.
48" O.C.
672# 1
(1) MTS 16
1000#
14-10d x 1-1/2"
TRUSS INFORMATION TAKEN FROM MANUFACTURER'S SHOP DRAWINGS. CHAMBERS TRUSS, JOB # 74048,
DATED 1111/2017. ALL LOADS REPRESENT WORST CASE LOADING FOR GROUPED CATEGORIES. REFER TO
MANUFACTURER'S TRUSS LAYOUT FOR TRUSS ID AND STRAPPING PLACEMENT.
FOUNDATION SCHEDULE
KEY DESCRIPTION
F-1
18" WIDE X 16" DEEP THICKENED EDGE FOOTING W/ (2) #5 BARS CONTINUOUS.
F-2
24" WIDE X 18" DEEP MONOLITHIC FOOTING W/ (3) #5 BARS CONTINUOUS.
S-1
4" (2500 PSI) POURED CONCRETE SLAB W/ FIB€RMESH REINFORCING ON 6MIL VAPOR
BARRIER OVER CLEAN, COMPACTED, TREATED FILL.
i
I
I
I
I
I
I
I
L---------
C2
FOUNDATION
1/4" = 11
-0"
PLAN
40'-0"
IN
CONIC. PAD -
FOUNDATION PLAN
Architectonic Inc
806 DELAWARE AVENUE
FORT PIERCE, FLORIDA 34950
T: 772 460 7751
F: 772 460 4244
W W W.ARCHITECTONICINC.COM
STATE REG # AA26003348
COPYRIGHT 2017
PROJECT
SALLVAD OSA
RESIDENCE
Vero Beach, Florida
CLIENT
RAFAEL SALGADOSA
1 CONSULTANTS
I REGISTRATION
i
* -v
MICHAEL J. SEAL, AIA
AR96898
REVISIONS
1:1:961reyk
KEY PLAN
SHEET TITLE / SHEET NUMBER
FOUNDATION PLAN
A2.00
PROJECT NUMBER 29827.00
DATE 03/14/2017
1-2 1/2" VTR
i
I ARCHITECT
Architectonic Ini
9
E
5 GARAGE DOOR BUCK DETAIL
w
m
Q
C�
P-2
P-3 P-1
RIDGE P-2
P-1 P-2
P-2
RIDGE
P-3 P-1
N N
P-1 °- a P-1
P-2 P-3 I P-3 P 2
GABLE
ROOF SHEATHING NAILING ZONE INFORMATION
-\O
3
M,gS�FR 3„
9q rti
SANITARY RISER DIAGRAM
7 3/4" = T 0"
TORSION BLOCK W/
1/2" X 5 1/2" REDHEAD
o
" 1'-0" V-0"
P.T. 2"X6" BUCK W/ 3/16" X 2 1/2"
TAPCONS @ 12" O.C. STAGGERED
0
P.T. 2"X6" BUCK W/ 1/2" X 5 1/2"
REDHEADS & 2" X 1/8" WASHERS
0
CP
0
it
P-3
IL
P-3
ZONE P1: REMAINING AREA W/ 8d RING SHANK @ 6" O.C. PERIMETER & 6" O.C. FIELD
ZONE P2: 4' LENTH W/ 8d RING SHANK @ 4" O.C. PERIMETER & 6" O.C. FIELD
ZONE P3: 5'X5' @ HIP AND 5' LENGTH @ GABLE ENDS W/ 8d RING SHANK @ 4" O.C. PERIMETER & 4" O.C. FIELD
NOTES
19/32" CDX PLYWOOD SHEATHING
25'-0" OR GREATER MEAN ROOF HEIGHT SHALL HAVE 10d RINGSHANK NAILS
UNDERLAYMENT FELT SHALL BE PEEL & STICK OR 30# FELT COMPLYING W/ ASTM D226
_(4 LEFT SIDE ELE
1/4
0
co
3 ROOF SHEATHING NAILING ZONE INFO. 2 PIPE B
1/2" = 1'-0" _ - - 3/4"
2" GALVANIZED PIPE W/
1/4" THICK WALL
4" COLLAR W/ (4) 1/4"X3"
TAPCONS
OLLARD DETAI
6 REAR ELEVATION - HOUSE
12
T.r,- 15
4
co
O
z
SS
LL. ,
0
806 DELAWARE AVENUE
FORT PIERCE, FLORIDA 34950
T: 772 460 7751
F: 772 460 4244
1L�1�i��13�771Ir��lYiLIL�]I►I�K�]u
STATE REG # AA26003348
COPYRIGHT 2017
PROJECT
TOP OF B OAO" SALGADOSA
RESIDENCE
IVero Beach, Florida
I CLIENT
1ST FLDOO
0 RAFAEL SALGADOSA
TOP OF BEAM
1ST FLOOR
0"
TOP OF BE
10'-0"
1ST FLOOR_Ad[-� �-w
o,.
I CONSULTANTS
I REGISTRATION
r
A .981
MICHAEL" T-SEAL, AIA
AR96898
REVISIONS
INO.1 DATE I REVISION
KEY PLAN
SHEET TITLE / SHEET NUMBER
EXTERIOR
ELEVATIONS
AIN
-PROJECT NUMBER 29827.
DATE 03/14/2U
STRUCTURAL NOTES:
1. STRUCTURAL LUMBER TO BE HEM -FIR #2 GRADE OR BETTER W/ 1000
PSI MIN. FIBER STRESS VALUE
2. CONCRETE SLABS AND FOOTINGS TO BE 2500 PSI MIN
3. REINFORCING STEEL SHALL BE GRADE 60 OR BETTER W/ 30" MIN.
LAP
4. CONCRETE COVER OVER REINFORCING STEEL:
A. FOOTINGS: 3"
B. BEAMS: 11/2"
C. COLUMNS: 11/2"
5. FILL (SOIL) SHALL BE PLACED IN LIFTS NOT TO EXCEED 12" AND
COMPACTED TO A MINIMUM OF 95% MODIFIED PROCTOR DENSITY
6. ALL COMPONENTS OF THIS STRUCTURE HAVE BEEN DESIGNED AND
SELECTED TO WITHSTAND FORCES PER THE FLORIDA BUILDING
CODE 2014 EDITION
7. DOOR & WINDOW ASSEMBLY COMPNENTS TO BE CERTIFIED BY
MANUFACTURER FOR WIND FORCES PER THE FLORIDA BUILDING
CODE 2014 EDITION PER WIND LOAD COMPLIANCE DESIGN
PRESSURES
8. PRECAST/ PRESTRESSED CONCRETE LINTELS TO HAVE 6" MINIMUM
BEARING. REFER TO LINTEL SCHEDULE FOR ADDITIONAL
INFORMATION.
9. FOR METHOD OF ATTACHMENT OF DOORS & WINDOWS, REFER TO
ATTACHED PRODUCT REVIEW AFFIDAVIT
NOTE: ALL SIMPSON STRONT-TIE PRODUCTS IN CONTACT WITH
TREATED LUMBER SHALL HAVE A MINIMUM Z-MAX COATING OR BETTER
5 RIGHT SIDE ELEVATION -GARAGE
1/4"
LEFT SIDE ELE
1/4" = 1'-0"
DRYWALL NOTES
DRYWALL SHALL CONFORM WITH SECTION R702.3.1 OF THE FLORIDA BUILDING CODE
(RESIDENTIAL).
CERAMIC TILE IN TUB/SHOWER COMPARTMENTS SHALL CONFORM WITH SECTION R702.4
OF THE FLORIDA BUILDING CODE (RESIDENTIAL).
WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF NOT
GREATER THAN 200 AND A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450.
ATTIC INSULATION SHALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER
SQUARE CENTIMETER WITH A FLAME SPREAD NOT EXCEEDING 25 WITH AN
ACCOMPANYING SMOKE -DEVELOPED INDEX NOT EXCEEDING 450,
FOAM BLOCK INSULATION SHALL HAVE A FLAME SPREAD OF NOT MORE THAN 75 AND
SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450.
DOOR & WINDOW BUCK FASTENING
DOOR AND WINDOW BUCKS SHALL BE ATTACHED WITH CASE HARD NAILS @ 12" G.C.,
WITH THE DOORS AND WINDOWS FASTENED W/ TAPCONS PER THE PRODUCT REVIEW
AFFIDAVIT WITH A MINIMUM OF 1 1/4" EMBEDMENT INTO CONCRETE (THROUGH FRAME).
BUCK SHALL EXTEND BEYOND THE INTERIOR FACE OF THE FRAME PER 2014 FLORIDA
BUILDING CODE W/ AMENDMENTS.
STUCCO NOTES
STUCCO ON RIBLATH OR PAPER BACK SHALL BE ATTACHED TO HORIZONTAL FRAMING
PER ASTM C-1063/ASTM C-926. LATH SHALL BE ATTACHED TO FRAMING MEMBERS WITH
CORROSION RESISTANT MATERIALS. ATTACHMENTS SHALL BE SPACED NOT MORIE THAN
6" O.C. ALONG SUPPORTS. FASTENERS TO BE USED CAN BE 6d COMMON OR ROOFING
NAILS HAVING A MIN. 3/4" PENETRATION INTO HORIZONTAL FRAMING MEMBERS OR
STAPLES W/ A MIN. 3/4" CROWN ENGAGED NOT LESS THAN (3) STRANDS OF LATH AND
MUST PENETRATE THE WOOD FRAMING MEMBERS 3/4" MIN.
VATION - GARAGE
DETACHED GARAGE
T.O.B.
14'-0" V
DETACHED GARAGE
REAR ELEVATION - GARAGE
1/4" = 1'-0"
2 FRONT ELEVATION - GARAGE
1/4 = 1 0
)_
RIGHT SIDE ELEVATION - HOUSE
1/4" = 1'-0"
DETACHED GARAGE
T.O.B.
14'-0" -70
DETACHED GARAGE
_ T.O.B.
14'-0"
TOP OF SLAB
B
o' �I
1STFLOOR
0.
ARCHITECT
Architectonic Inc
806 DELAWARE AVENUE
FORT PIERCE, FLORIDA 34950
T: 772 460 7751
F: 772 460 4244
W W W.ARCHITECTONICINC.COM
STATE REG # AA26003348
COPYRIGHT 2017
PROJECT
SALGADOSA
RESIDENCE
Vero Beach, Florida
CLIENT
RAFAEL SALGADOSA
CONSULTANTS
REGISTRATION
"'0 OF_FLO�
n s
MICHAEL J. SEAL, AIA
AR96898
REVISIONS
NO.
DATE
REVISION
KEY PLAN
SHEET TITLE / SHEET NUMBER
EXTERIOR
ELEVATIONS
A4.00
PROJECT NUMBER 29827.00
DATE 03/14/2017
ARCHITECT
WINDOW
CAULKIN(
STUCCO
NATERPROOFING (CONCRETE
SEALER BEFORE & AFTER BUCK
INSTALLATION) TYP. OF ALL 4
3 1 D E S
WINDOW FLASHING n- WINDOW
1 1/2" = 1'-0"
METAL ROOFING ON 30# FELT
UNDERLAYMENT ON 5/8" CDX
PLYWOOD NAILED PER ROOF
SHEATHING NAILING ZONE DETAIL
SIMPSON HETA 20 PER SCHEDULE
PRE-ENGINEERED WOOD
TRUSSES @ 24" MAX - REFER TO
MANUF. SHOP DRAWINGS
METAL DRIP EDGE
1"X6" R.S.C. FASCIA ON 2"X4"
SUB -FASCIA
STUCCO SOFFIT ON RIBLATH W/
CONTINUOUS SCREEN VENT —
R-30 FIBERGLASS BATT INSULATION
(2) COURSES OF CONC. BILK. BOND
BEAM W/ (1) #5 BAR EACH
T1711 Innrn n nAll l l
SIMPSON
OVERFRAI
10d NAILS
lJV1VIVLV I VI\ U 1 11\VUJ VVIVlr f11V 1
12
5�— _ OVERFRAMED TRUSS DETAIL
O 1,1 = 1'-01, --- - -- ----- - - ---
1 /2" GYP. BOARD
CEILING
SIMPSON HETA 20 PER
20 SCHEDULE
TYP
12
5
8" PRECAST LINTEL W/ 1 #5 BAR
& 8" BOND BEAM W/ 1 #5 BAR
PRE -CAST LINTEL @ DOOR &
STUCCO ON RIB LATH OR 5/8
WINDOW OPENINGS - REFER TO i I
LINTEL SCHEDULE FOR o EXTERIOR SOFFIT BOARD W/ 1
ADDITIONAL INFORMATION Nt 1/2" DRYWALL SCREWS @ 4"
O.C. PERIMETER & 8" O.C. FIELD
I � �
i
12"x12" CONCRETE BLOCK
COLUMN W/ (4) #5 BAR IN GROUT
PAINT INTERIOR OF WALLS FILLED CELLS — -
I � o
#5 VERTICAL DOWELS IN CONC. STUCCO FINISH
FILLED BLOCK CELLS @ CORNERS,
EACH SIDE OF OPENINGS AND @
4'-0" O.C. MAX. REFER TO FLOOR REFER TO FOUNDATION PLAN
PLAN FOR EXACT LOCATIONS FOR SIZES AND REINFORCING
777
I I
STUCCO FINISH
NOTE: REFER TO TYPICAL WALL
SECTION FOR ADDITIONAL I -
REFER TO FOUNDATION PLAN FOR SIZES INFOMRATION
AND REINFORCING
° Le • e ia° al I
:La��� IIII1
—III—III— : _ .y I—IIIII IIIIIII IIIII I
11=1 I I1 I �_ _� I I=1 I I —III —III 111 111 I I I '� 111 I II 111
6MIL VAPOR BARRIER _ pp I IIIIIIIIIIIIIIII1 � I1 —IIIIIIIIIIIIIII—III IIIIIII I
3 TYPICAL WALL SECTION @ DETACHED GARAGE 2 COLUMN DETAIL
2"X4" TOP PLATE
3YP. BOARD CLGS & WALLS
STUDS @ 24" O.C.
"'X4" BOTTOM PLATE
AS SELECTED BY OWNER
INTERIOR PARTITION DETAIL
3/4" = 1'-0"
METAL ROOFING ON 30# FELT
UNDERLAYMENT ON 5/8" CDX
PLYWOOD NAILED PER ROOF
SHEATHING NAILING ZONE DETAIL
1
PRE -EN INE'ERED WOOD
TRUSSES @ 24" MAX - REFER TO
MANUF. SHOP DRAWINGS
R-30 FIBERGLASS BATT INSULATION
SIMPSON HETA 20 PER SCHEDULE -
METAL DRIP EDGE
1"X6" R.S.C. FASCIA ON 2"X4"
SUB -FASCIA
STUCCO SOFFIT ON RIBLATH W/
CONTINUOUS SCREEN VENT
(2) COURSES OF CONC. BILK. BOND
BEAM W/ (1) #5 BAR EACH
PRE -CAST LINTEL @ DOOR &
WINDOW OPENINGS - REFER TO
LINTEL SCHEDULE FOR
ADDITIONAL INFORMATION
1/2" GYP BOARD ON 1"X2" P.T.
FURRING @ 16" O.C. W/ 3/4" RIGID
INSULATION
#5 VERTICAL DOWELS IN CONC.
FILLED BLOCK CELLS @ CORNERS,
EACH SIDE OF OPENINGS AND @
6'-0" O.C. MAX. REFER TO FLOOR
PLAN FOR EXACT LOCATIONS
STUCCO FINISH I
REFER TO FOUNDATION PLAN FOR SIZES
AND REINFORCING i
6MIL VAPOR BARRIER
TYPICAL WA
3/411 = 1'-01,
II=1 III
LL SECTION
12
5
1/2" GYP. BOARD
CEILING
WOOD
BASE
e
�
e- a
L
a
_
I IIIIIII—III:
—
_
_�
�
Architectonic Inc
806 DELAWARE AVENUE
FORT PIERCE, FLORIDA 34950
T: 772 460 7751
F: 772 460 4244
W W W.ARCHITECTONICINC.COM
STATE REG # AA26003348
COPYRIGHT 2017
ZOJECT
SALGADOSA
RESIDENCE
IVero Beach, Florida
I CLIENT
RAFAEL SALGADOSA
1 CONSULTANTS
I REGISTRATION
�j••GNPELJ.g 9
R96898
STFRED AaG�
MICHAEL J. SEAL, AIA
AR96898
IREVISIONS
NO. I DATE REVISION
1 04/28/17 1 BLDG DEPT COMMENTS
I
KEY PLAN
' SHEET TITLE / SHEET NUMBER
DETAILS
A5.00
PROJECT NUMBER 29827.00
DATE 04/28/2017
ARCHITECT
Architectonic Inc
ELECTRICAL LOAD CALCUATIONS
HOUSE
2,493 SQUARE FEET @ 3VA/SF
7,479 VA
2 APLIANCE CIRCUITS
3,000 VA
1 DRYER
5,000 VA
1 LAUNDRY
1,500 VA
1 DISHWASHER
1,200 VA
1 REFIGERATOR
1,200 VA
1 RANGE/ OVEN
12,000 VA
1.DISPOSAL
800 VA
1 WATER HEATER
4,500 VA
1 MISC
2,000 VA
SUBTOTAL
38,679 VA
FIRST 10,000 VA @ 100%
10,000 VA
REAINDER @ 40%
11,472 VA
1 A/C & HEAT SYSTEM
12,000 VA
TOTAL
33,472 VA
33.472
240 140 AMPS
GARAGE
1,200 SQUARE FEET @ 4.5VA/SF
5,400 VA
1 WELDER
10,000 VA
1 COMPRESSOR
5,000 VA
1 MISCELLANEOUS
5,000 VA
SUBTOTAL
25,400 VA
FIRST 10,000 VA @ 100%
10,000 VA
REAINDER @ 40%
15,400 VA
1 A/C & HEAT SYSTEM
5,000 VA
TOTAL
30,400 VA
240 126 AMPS
USE NEW 300 AMP SERVICE
PROVIDE ARC FAULT AND TAMPER PROOF RECEPTACLES
THROUGHOUT
ELECTRICAL SERVICE
(3) 350 MCM, IN 2 1/2" CONDUIT
3# 1/0, #6, 1 1/2" CONDUIT
GARAGE HOUSE
120/240V O 120/240V
1 PH. 1 PH.
150A 150A
MAIN BR. MAIN BR.
#3 CU. GROUND TIED TO BLDG.
STEEL, CWB & DRIVEN GROUND ROD
ELECTRICAL RISER DIAGRAM
COPPER SERVICE
ELECTRICAL LEGEND
P SINGLE POLE SWITCH
�3 THREE WAY SWITCH
DUPLEX CONVENIENCE OUTLET
DUPLEX OUTLET W/ GROUND FAULT PROTECTION
DUPLEX OUTLET WEATHER PROOF & GFI
220V OUTLET
E) MOTOR OUTLET
tpr WALL MOUNT LIGHT FIXTURE
CEILING MOUNT LIGHT FIXTURE
10N RECESSED LIGHT FIXTURE
❑ JUNCTION BOX FOR FAN/ LIGHT COMBO
1,7 PHONE OULET
IJ CABLE TELEVISION OUTLET
�S1 SMOKE DETECTOR/ CARBON MONOXIDE
---0 DOORBELL
CH CHIMES
220/GFI G.FI GFI
i
i
i
GFI /
GARAGE
� I
1/2 BATH-
L
SP---
•
/
1
1� HOBBY ROOM
GFI
----------------------------------�
u
.
.
] -Ell�'�]
® WP/GFI
y
6
ELECTRIC
METER
� 1 I
1 r
i r
1 /
I /
1 /
I /
I
TO LAMP POST
1
I
I
i
I
i
I
I
I
I
r
r
r
r
r
r
r
806 DELAWARE AVENUE
FORT PIERCE, FLORIDA 34950
T: 772 460 7751
F: 772 460 4244
W W W.ARCHITECTON ICINC.COM
STATE REG # AA26003348
COPYRIGHT 2017
I PROJECT
SALGADOSA
RESIDENCE
Vero Beach, Florida
CLIENT
RAFAEL SALGADOSA
1 CONSULTANTS
1 REGISTRATION
y,' �pELJ. S E
y� ,
R9689i?'' -
MICHAEL J. SEAL, AIA
AR96898
REVISIONS
INO.1 DATE I REVISION
KEY PLAN
ISHEET TITLE / SHEET NUMBER
ELECTRICAL PLANS
2 1 ST FLOOR PLAN
1/4" = V-0"
0
1 1ST FLOOR ELECTRICAL PLAN
1411
A6.00
PROJECT NUMBER 29827.00
DATE
03/14/2017