HomeMy WebLinkAboutApproved PlansPlanning & Development Services Department
o Building & Code Regulations Division
* 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553
Certification for Design Load Compliance
Project Name: HALL ADDITION
Project Address: 1040 PULITZER RD.
Permit #: Occupancy Type: R Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit 2 copies for residential 3 copies for commercial with all permit applications involving the following: ub ()cop , () p P aPP g
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code 2014 Edition with 20 _Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _ Partially Enclosed _Open
3. Risk Category: _I X II_ III IV Exposure Category: _ B X C_ D
4. Design Wind Velocity 160 mph 124 ASO N/A LRFD End Zone Width: 5 ft
S. Mean Roof Height: 15 ft Roof Pitch: 3.5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
19.3 19.3 19.3 33.6 33.6 N/A
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
-30.7 -53.5 -79.1 -36.4 -44.9 N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony: , N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
Building Permit #
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name IAAU-- Applicant:
Product
Opening Design
Pressures
Product Rated
Deal n Pressure
ManWaeturer
Model Number
Product Approval
Number
Glass
T
Method of Attachment
y
Windows a6YoF 1}
"r.7t'P ��^I,t+` 1,7,
-0f, SS
m-T
Gcx+,e�
�j14 /CJJ
ro.(!-rtl'M,I
a-N,P*t'
�8r J, �M/N 6sOv, -Nee NSQi "/R ex, r/N
IF/uulriw, (Vffoi7
it `r
al� iP
plsT
'541 -55c0
NoAx* IGr'0714,03
IMPacY
J Io q I'la'MiN AT 4` 0,t,ar,U
Fixed Glass
N l�
r�
�Vnin T rb(,G e-"
TulietUA 1V0
SWOTeI Sfct.
Rk 15201,5
IV A
-410 r I' Z'sA Cr A&SO .S[.ZBWS A17
Swino Type Doors
5ve tFWV15
q-l. 7(9
lvA56N1Tr
'7`(v-FI. OP4A
F0 A104..1
NIA
0/0Y lN/M, toae-6 gcper s 4-r
'b10 0 -4 4 ,
a2
341e,1%SllAkR
Itow cRov C
NOA-A15'404
R1A
FER 51 UCr, NoTS -All PIAN S14IFFT#'L
":Dt9FFa/-t
1'3141-.14.1
•..450
a0u �re��,
TRIP 4:.
-r-La1`4Ooq-I
N 1A
PIFR. SOF�ITDETAIL, ON F%AN 5At T-4T,
.�w.��s.a
`f0 FW2�6121LI
7-7..
'f
I+I�I(.%1tINTE"T:
ivlo l�, hjl Tl
I�PAII )Li•0$2`1,62
f�l
? i�LhN �U.EET 3LJ `�'•..,....
RocPing Material
µrtnd,7
- 79,1
-Ra$,5
(,ge Cmast
5Y'L2iM/
(llp5/,l
N��It
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
Name' _PAUL WELCH P.E. Signature: ON PLAN J f
Design Prof: PAUL WELCH P.F.'' Cert. No. 29945 Date:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes rJP:
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to* r-T
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Paul Welch P.E. 29945 / 5115
Print Name Cert It & Co, Cent Auth.
Paul Welch Inc.
ON PLAN 2/2/2017
Signature, Date, and Seal 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL
Company Name & Address
SLCCDV Form # 020-12 Revised 3/15/12 (15)
c
- "fin Y4",cCALL
LT-fP�
wALL+svis 7..t.Y R7z�
GRADE D FELT PAPER %
PROVIDE BEAD OF SEALANT "
FROM EDGE OF OPENING UNDER FELT
APPLY FELT TO EXTERIOR OF
OPENING AND FOLD FELT OVER JAMBS
DOOR OPENING
�I JJ -. DOOR OPENING WATERPROOF CD&TAIL
IY/ NOTE. APPROVED PEEL AND STICK MAY BE USED IN LIEU OF GRADED
File Copy
I \�
~' SCOPE OF WORK
f
FL IvrsrvfD CONSTRUCT COVERED PORCH ADDITION PER PLAN.
,ii III
=
watt a'sttlsN�Iwsufa CONSTRUCT BATHROOM ADDITION PER PLAN.
I II
i
GRAllsDFELTPAPER(APPL®✓ T1 - CONVERT EXISTING BATHROOM INTO CLOSET / HALLWAY PER PLAN.
'III II
PROVIDE BEAD OF SEALANT''/."
al
9
FROM EDGE OFOPENING UNDER FELT THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 2014 FOR
APPLY FELT TO EXTERIOR OF
OPENING AND FOLD FELT OVER JAMBS EXISTING BUILDINGS CHAPTER R.
1.
!
wINDDw OPENING NOTES:
lls
. GRADE D FELT PAPER SILL PANNING
(APPLIED I) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL
WRAP OVER ENTIRE SILL, OVER DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT.
LAP SILL PANNING 4^ PROVIDE 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE
BEAD OFN NG LANT M" UNDERFE FROM EDGE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES.
OF OPENING UNDER FELT
1
3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER
I'
it 'I
i
GRADE DFELT PAPER APPRON (APPLIED 1n) `
9" WIDE CONITNUOUS UNDER SILL PROVIDE I SCALED DIMENSIONS.
`
BEAD oaSEALANT Y4"FROMEDGE 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE
'
_I
OF OPENING UNDER FELT
(FBC) 2014, FBC 2014 RESIDENTIAL, FBC 2014 PLUMBING CODE, FBC 2014
MECHANICAL CODE, FBC 2014 ENERGY CONSERVATION, AND THE NEC (NFPA
70) 2011 EDITION.
5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY IIEAVY
TERMITE INFESTATION AREA PER FRC 301.
J
6) ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0
2014 FOR EXISTING BUILDINGS.
WINDOW OPENING WATERPROOFI IG DETAIL HUC48 HANGER AT COV. PORCH
NOTE APPROVED PEEL AND STICK MAY BE USED IN LIEU OF GRADE DFELT. _.. USE "SIMPSON" HUC48 WITH (14)- 16d NAILS
TO EXISTING WALL OR POST
U
(6)-10d NAILS TO BEAM
CONGEALED FASTENEPS'OR ATTACHhiEAND
— ARE THE RESPONSIBILRY OF THE
--- ----.�
OUTWOR 4F CORD THESE PLANS AND ALL PROPOSED WORK
1i4 ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
0 MAY BB NECESSARY IWORDER,TO
ALL COMPLY WITH ALL APPLICABLE CODES."
MANUFAGTURa LURES SHOWING
U FACTORS AND SH(3C COMPLIANCE
WITH FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
\\LST
4111 pos-1 trrrj
UNTIL INSPECTIONS ARE APPROVED I NO.0SoL
LUCTF t•o U Tti RiTIT In",` T)TVISION
/�n� 1�;+
R'FVrrWiiTFv OFi �1?,iCE
A1,VIE't i B S 1(LG V�
DATE
Gad, ® I
ORNN0 INSPECTIPLAAND ON WILL HE A ADE.IT MUST BE KEPT O S JOW
TERMITE TREATMENT REQUIRED
cda
re KzaN
r
2> (v v] POP roof
�.,
,erg
lT'fP1CC.l-1' \/
.
.ems
f
IF\ \
�: ' C
pro p �^tyN
1 ?-i w ..7 x,i°°'.D.I K124P �.2
{
\ x
�xl�TljIIA 1,
\ + Zlo. _
• • � Iiy15T I�A'Iu�ool�t
AND F-EMopEL• Fv�
` L\Ln9E fRoss
w e\ I latir�b G —�p �A n� �InLI
A u 2%68 IT:tAPi
XI�T. Aral�� A4e. o
L W Nv'� t1I
• / S eWT
;1,1Z G , M
Ito
WG hPxE , LA,'/ T
R tr, H, IV E. D
APR 14 20V
PERMITTING
n�^
St. Lucie County, FL
L00 L.& 'A
H \L,L�C L N-C6 U PAUL WEI.CHINC.
IMECHANI+CAL ELECTRICAL CIVIL ENGINEERING
I9&4S. W &A-7NOREST. SUITE# 114
PORTST. LUCIE, FL34984,
PHONE (772) 7115 -9888 E-MAIL PWELCH/NC@TAOL COM
PAUL WELCH, P.E. FLA REG NO.29945
APR 1 41C17
6
R-30 INSULATION` -,
Y2" DRYWALL CLG ---
SIMPSON SP4 W/ (6)-1OD NAILS
EACH STUD TOP AND BOT. -
PLATE
R-11 INSULATION --- --
/2" DRYWALL - --- - -
WOOD OR VINYL BASE --
FLOORING PER OWNER
'�1 s
METAL ROOFING OVER 30 #
FELT ON 19/32" CDX
PLYWOOD SHEATHING
NAILED W/ 8d RINGSHANK
NAILS @ 4" O.C. PERIMETER
AND 6" O.C. FIELD
PRE-ENGINEERED ROOF
- TRUSSES @ 24" O.C. MAX
_ SIMPSON STRAP PER TRUSS
CONNECTOR SCH.
✓ ALUM. DRIP EDGE
_ 1 X 6 P.T. WD.FASCL4 OVER
2X4 P.T. WD. SUB -FASCIA
- - - SOFFIT PER DETAIL
DBL 2X4 CONT. WOOD TOP
PLATE
2 X 4 WD STUDS @ 16" O.C.
HARDIE PLANK SIDING PER
STRUCTURAL NOTES
2 X 4 P.T. WD BOTTOM PLATE
--------- W/ V2" 0 X 8" EMBED ANCHOR
BOLTS W/ 2" X 2" WASHERS @
24" O.C.
FINISHED GRADE
18" DEEP X 16" WIDE (2500 PSI)
CONC, FOOTING WITH (2)- 35
BARS CONTINUOUS (PER SCH)
TYPICAL FRAME BRIG. WALL DETAIL nt9
EXISTING ROOFING
METAL FLASHING AT PITCH
CHANGE
2X6 WOOD JOIST AT 24" O.C.
—SIMPSON STRAP NITS 16 WITH
(10)-1Od X 1 W' EACH JOIST
EXISTING FRAME WALL /
HEADER
ROOF TO EXIST. WALL DETAIL its...
(COV. PORCH)
_
2X4 VERTICAL SUPPORT AT SW O.C.
MAX
2X2 OR 2X4 CONTINUOUS AT ALL LEVEL
RETURNS OR AREAS OPEN TO ATTIC
SPACE
FASCIA
ALUMINUM FASCIA TRIM
#15 X 13W %S. TRIM NAIL INTO FASCIA
AT 16" O.0
18 GA. X'/." S.S. STAPLE W/ 7/8" MIN.
EMBEDMENT AT 8" O.C. INSTALLED IN
END OF PNL
QUAD PANEL ALUMINUM VENTED
SOFFIT "ACM"
18 GA. X VV S.S. STAPLE W/ 7/8" MIN.
EMBEDMENT AT 24" O.C. TO 2X4 CONT.
F" CHANNEL 0,0155" THK ALUM. WITH
8 GA. X %11 S.S. STAPLE W/ 7/8" MIN.
;MBEDMENT AT 12" O.C. AT F CHANNEL
AEG AND F CHANNEL SLOT
SOFFIT DETAIL nts...
AS PER FL#12019.1 MNFG: AMERICAN CONSTRUCTION METALS "AMC"
REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS FOR MORE INFORMATION
0
MAXIMUM HEADRER SPAN
NUMBER OF FULL LENTH STUDS EACH END OF HEADER
NUMBER OF HEADER STUDS SUPPORTING END OF HEADER
LIU
_ II_
K
DOOR OR WINDOW OPENING
DBL 2X4 SILL
(WINDOW ONLY)
130 STUDS AT 16" O,C:.
(WINDOW ONLY)
TT _ _
I�
TYPICAL HEADER DETAIL nts
TYPICAL 4X4 POST DETAILatg...
ky
TORH DOWN ROOFING PER
ROOF ATTACHMENT
�UIREMENTS PLAN SHEET
WOOD JOIST AT 24" O.C.
PSON STRAP MTS16 WITH
lOd X 1 '/2" EACH JOIST
JM. DRIP EDGE
P.T. WD. FASCIA
WD, SUB -FASCIA
8 WOOD HEADER WITH
IPSON AC4 W/ (28)-16d
ILS EACH POST TO
ADER (USE SIMPSON LCE4
_ORNER POSTS WITH (24)-
1 NAILS)
APSON LSTA 18 W/ (14)- 10d
AILS AT CORNER POSTS (1)
R HEADER
T. 4X4 WOOD POST
MPSON ABU44 WITH (12)-
id AND (1)- 5/8"51 X 12"
NCHORBOLT
RUSHED GRADE
?500 PSI) CONC.
OUNDATION (PER SCH)
5'-O"
1T=0"
M
33
2
3
1 1 2
UUSSES OR ROOF JOIST PER PLANT
DBL 2 X 4 TOP PLATE
STRAP EACH STUD TO TOP PLATE
WITH-SIMPSON" SPH4 WITH (10) -
lOdX 1 V2" NAILS
STRAP EACH STUD TO HEADER
WITH "SIMPSON' LSTA 24 WITH (18)-
I Od NAILS
DBL 2 X 12 WOOD BEAM WITH V2"
PLYWOOD SPACER GLUED AND
NAILED WITH 10d NAILS AT 8" O.C.
STAGGERED TOP AND BQTTOM
BOTH SIDES
FULL LENGTH 2 X 4 WOOD STUDS
HEADER STUDS 2 X 4 WOOD STUDS
STRAP EACH STUD TO BOTTOM
- PLATE WITH "SIMPSON" SPH4 WITH
(10) - I Od NAILS
P.T. 2 X 4 WOOD BOTTOM PLATE
0)- 518" WEDGE ANCHORS X 8"
EMBED. WITH 2" X 2" X 1/8"
WASHERS EACH SIDE OF OPENING
AND 24" O.C.
G- -CONCRETE FLOOR / FOOTING
STRUCTURAL NOTES
1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10.
2) SOIL BEARING CAPACITY: 2500 PSF (MIN.).
3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICLE CELLS, AND
COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI
COMPRESSIVE STRENGTH AT 28 DAYS.
4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE
STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS.
5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTINGS: 3" BEAMS: 1 VS" SUSPENDED SLABS: 1 V2"
6) LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS
NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS.
7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED.
8) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO
INSTALATION OF HARDWARE IS NOT PERMITED.
9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE
SHALL CONFORM TO THE MANUFACTURE6INSTRUCTIONS AND STANDARD
PRACTICIES.
10) UNLESS OTHERWISE NOTED, ROOF SHEATHING TO BE NAILED WITH 8d RING -
SHANK NAILS AT 4" O.C. PERIMETER AND W O.C. FIELD.. ---�
11) HMOVER-LAPPED
ANK HARDIEPLANK SIDING TO 8E ATTACHED OVER TYVAK
BWRAP OR 15# FELT OVER PLYWOOD. HARDI2LANK TO APPLIED
HALLY WIT a APS AT TOP OF PLANK. HARDIPLANK TO BE
AD WITH FASTENERS 2 %" LONG, 0.223" HEAD DIAMETER, 0.092" SHANK
D, CORROSION -RESISTANT SIDING NAIL. FASTENERS SHALL BE
PTHE OVER -LAPPED AREA AT < 8-1/4" ON CENTER VERTICALLY AND16TER HORIZONTALLY INTO STUDS THROUGH 5/8"PLYWOODSG. 5/8" PLYWOOD SHEATHING TO BE NAILED TO STUDS WITH 8DN" O.C. PERIMETER AND FIELD.
WALL FINISH / INSULATION NOTES
1) INTERIOR TO BE V2" DRYWALL FINISH.
2) ALL INTERIOR GYPSUM BOARD TO BE MIN. V2" THICK WITH (13 GAGE, 1 3/8"
LONG, 19/64" HEAD; 0.098" DIAMETER, 1'/"" LONG, ANNULAR -RINGED; 5D
COOLER NAIL, 0.086" DIAMETER, 15/8" LONG, 15/64" HEAD; OR GYPSUM BOARD
NAIL, 0.086" DIAMETER, 15/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS
AND 12" O.C. FOR SCREWS.
3) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS
MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR
C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS'
RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2).
4) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF
NOT GREATER THAN 450.
5) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD
CLASSIFICATION OF NOT GREATER THAN 200..
6) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL
HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE
CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO
THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL
COMPLY WITH SECTION FRC316.
7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL
CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C
1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN
ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE
INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557
8) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS
OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING
ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL
SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25
WITH AN ACCOMPANYING SMOKE-DEVI LOPED INDEX NOT TO EXCEED 450
WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
ENERGY CONSERVATION NOTES
1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014
ENERGY CONSERVATION RESIDENTIAL.
2) CEILINGS WITH ATTIC SPACES SHALL HE INSULATED WITH R-38 INSULATION.
3) THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR
LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS R402.4.1 THROUGH
R402.4.4.
4) WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR
INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND
SWINGING DOORS NO MORE THAN 0.5 C�'M PER SQUARE FT AND MUST BE
TESTED LISTED AND LABELED IN ACCORDANCE WITH R402.4.3.
5) CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY
CARD IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION R401.3.
CONCRETE FOUNDATION NOTES _
I)SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 P5I COMPRESSIVE
STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS.
2)MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3"
SUBGRADE PREPERATION NOTES
1) THE AREA WITHIN THE LIMITS OF THE FOUNDATION SHALL HAVE ALL
VEGETATION, TOP SOIL AND FOREIGN MATERIAL REMOVED.
2) CLEAN FILL SAND AND OR GRAVEL FILL, FREE OF VEGETATION AND FOREIGN
MATERIAL, MUST BE PLACED TO DESIGN SUBGRADE LEVEL AND COMPACTED TO
ASSURE UNIFORM SUPPORT OF THE FLOOR SLAB.
3) SUBGRADE COMPACTION SHALL BE ACHIEVED BY MEANS AND METHODS
DETERMINED BY THE RESPONSIBLE CONTRACTOR. SOIL DENSITY TESTING BY
INDEPENDENT SOILS TESTING FIRM SHALL BE REQUIRED TO INSURE PRESCRIBED
SOIL DENSITIES ARE ACHIEVED.
4) AFTER FOOTING EXCAVATION, AND FORMING, CONTRACTOR SHALL RECOMPACT
SUBGRADE SOILS USING SUITABLE VIBRATORY MECHANICAL COMPACTOR THE
UPPER 16 INCHES OF SOILS UNDERLAYING THE WALL FOOTINGS SHOULD HAVE A
MINIMUM DENSITY OF 95% OF THE MAXIMUM DRY UNIT DENSITY AS DETERMINED
BY MODIFIED PROCTOR METHOD FOR THE EXISTING SOILS. IN -PLACE SOIL DENSITY
TESTS SHOULD BE PERFORMED IN ACCORDANCE WITH ASTM D-2922, AT A
FREQUENCY DETERMINED BY THE SOIL TECHNICIAN TO VERIFY UNIFORMITY OF THE
UNDERLYING SOIL DENSITY, PRIOR TO PLACING CONCRETE,
5) SUBBASE COMPACTION FOR THE FLOOR SLAB FILL MATERIAL SHALL BE
UNIFORMLY COMPACTED TO A MINIMUM DENSITY EQUAL TG 95% OF THE MAXIMUM
DRY UNIT' DENSITY OF THE FILL AS DETERMINED BY MODIFIED PROCTOR METHOD IN
ACCORDANCE WITH ASTM D-1557.
6) CONCRETE SLABS ON GRADE SHALL BE PLACED OVER A POLYETHYLENE VAPOR
j BARRIER WITH A MINIMUM THICKNESS OF 6 MILLS, INSTALLED WITH LAPPED JOINTS
NOT LESS THAN 6INCHES AND CONTINUOUSLY TAPPED WITH HIGH DENSITY
POLYETHYLENE ADHESIVE TAPE.
- - File Copy
r
z to §.4
k a
P
E F o OPT
PLUMBING NOTES:
1) ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2014-PLUMBING
2) DW V PIPING SHALL BE SCHEDULE 40 PVC.
3) WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L
COPPER, CPVC, OR PEX.
4) SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND
WITHIN BLDG.
5) HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL
BE APPLIED TO PIPING LARGER THAN %" NOMINAL DIAMETER, PIPINGFROM
WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE
CONDITIONED SPACE, PIPING FROM THE WATER HEATER TO THE
DISTRIBUTION MANIFOLD, PIPING LOCATED UNDER THE FLOOR SLAB,
HURRIED PIPING, SUPPLY AND RETUN PIPING IN RECIRCULATION SYSTEMS,
PIPING WITH RUN LENGTHS GREATER THAN 20 FEET.
MON SCHEDULE
18" DEEP X 16" WIDE (2500 PSI) CONCRETE MONOLITHIC
FOOTING W/ (2)- #5 BARS CONTINUOUS
8" DEEP X 8" WIDE (2500 PSI) CONCRETE MONOLITHIC
FOOTING W/ (1)- #5 BARS CONTINI30US
4" THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH
OR 6"/ 6" 10/10 W WM OVER VAPOR BARRIER ON
CLEAN COMPACTED CHEMICALLY TREATED FILL
#5 BARS X 12" LONG DRILLED OUT & EPDXIED
WITH 6" MINIMUM EMBEDMENT @ 24" O.C.
ALL AREAS ADJACENT TO EXISTING FOUNDATION
PAUL WELCH INC.
MEECWAN/CAL ELE'CTR/CAL C/V/L ENGINEER/NG
f984S. W. BILTMOREST, SUITE # f 14
PORTST; LUCIE, FL 34984.
PHONE (772d 788-9888 E-MAIL PWE'LCH/NC&DAOL COM .
PAUL WELCH, P.E. FLA REGNO. 29948
APR 1 4 2017
TRUSS CONNECTOR SCHEDULE
TRUSS ID
BEARING POINT
TRUSS ACTUAL
CONNECTOR
CONNECTOR
FASTENERS
NOTES
UPLIFT
ID
UPLIFT DESIGN
A01
EACH
308
(1)- MIS 16
1000
(14)-10d X 11/2"
AO1GE
CONT.
217 PLF
( )-LSTA15
1110
(12)- 10d
SEE GABLE END
DETAIL
1 STRAP AT EACH END AND AT 24 O.C.
VALLEYS
CONT.
100 # PLF
( )- MIS 16
1000
(14)-10d X 11/2"
1
( 1 STRAP AT EACH END AND AT 24" O.C.
ALL OTHERS AT
FRAME BEARING
LESS THAN 1000#
EACH
< 1000#
(1)- MTS 16
1000
(14)-10d X 11/2"
AT FRAME BEARING
TRUSS COMPANY
ECT
LAYOUT DATE
2 22 2017
CUT -SHEET DATE
2 24 2017
NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED.
NOTES
1 VALLEY TRUSSES MAY BE ATTACHED WITH SIMPSON VTCR W/ (4)- #9 SD X 2 1/2" TO SUPPORTING TRUSS AND (3)- #9 SO X 11/2"
TO VALLEY TRUSS IN LIEU OF MTS16 AS STATED. VTCR SHALL BE INSTALLED AT EACH END AND 24" O.C. MAX.
TRUSS NOTES:
1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER.
2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED
TRUSS DRAWINGS BEFORE INSTALLING TRUSSES.
3) CONTRACTOR TO VERIFY ALL EXISTING ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING,
AND INSTALLING TRUSSES.
4) TRUSS TO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY.
5) SEE TRUSS CONNECTOR SCH. FOR TRUSS TO WALL CONNECTIONS.
TORCHDOWN ROOF ATTACHMENT
ROOF ATTACHMENT REQUIREMENTS
ROOF DATA:
Manufacturer:
CERTAINTEED
- - ` Type:
MODIFIED BITUMEN
NOA#:
14-0529,02
System Type:
E(7) Base sheet Mechanically fastened page 27 of 42
Design Pressure:
60 (-PSF) PER NOA
Membrane Type:
SBS MODIFIED
Deck:
19/32 " Plywood
Base Sheet:
All Weather / Empire Base
Fasteners:
11 ga annular ring shank nails and approved tin caps
(spacing per base sheet attachment requirements)
BASE SHEET ATTACHMENT REQUIREMENTS:
ZONE 1 :
Base sheet attached to deck with Fasteners as specified above
(Field)
at 8 " O.C. in ( 4 ) rows. One row is in the side lap. The other rows
are equally spaced approximately 9 " O.C. in the field of the sheet.
(METHOD PERNOA) Design Pressure (-PSF): 60
ZONE 2:
Base sheet attached to deck with Fasteners as specified above
(Perimeter/ Ridge)
at 8 " O.C. in ( 4 ) rows. One row is in the side lap. The other rows
are equally spaced approximately 9" O.C. in the field of the sheet.
(METHOD PER NOA) Design Pressure (-PSF): 60
ZONE 3:
Base sheet attached to deck with Fasteners as specified above
(Corners)
at 4 " O.C. in ( 4) rows. One row is in the side lap. The other rows
are equally spaced approximately 9 " O.C. in the field of the sheeL
(ENHANCED FASTENERS) Design Pressure (-PSF): 106.67
MEMBRANE REOUIREMENTS:
One ply of Flintlast FR Cap 30 TCoolStar torch adhered to base sheet.
SURFACING
Any of the approved surfacing options as per Table 4 of the Product Approval
DECK INSTALLATION:
Nail all plywood sheathing (19/32" thick minimum) with 8D ring -shank nails at 4" O.C.
perimeter and 6" O.C. field for all zones.
NOTE: REFER TO MANUFACTURER'S SPECIFICATIONS AND INSTALLATION
INSTRUCTIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
4
A01
A01
A01
A01
A01 GE
EXISTING:
VERIFY ALL CONDITIONS,
PITCH, HEEL & DIMENSIONS
ADDITION NOTE
IT IS THE BUILDERS RESPONSIBILITY TO
VERIFY ALL EXISTING CONDITIONS,
EAST COAST TRUSS CANNOT BE
RESPONSIBLE FOR MATCHING
EXISTING ROOF CONDITIONS.
UPON SIGNING, BUILDER AGREES
TO ALL CONDITIONS AS
SHOWN ON THIS LAYOUT
9, 3„ J
MV5
A02GE
-
— - ------
— o
I
2' 1
1 /2"
0
0
0
- -
151011 -_— -�
TRUSS PLACEMENT PLAN nts...
METAL ROOF ATTACHMENT
- (1) #9-15 x 1-1/2'' HWH w/Sealing Washer
r I
At Panel Lap—/
PANEL FASTENER: #9 - 15 X I Y2" WOODGRIP WITH SEALING WASHER IN THE RIB OF THE PANEL,
%4" MINIMUM PENETRATION THROUGH THE PLYWOOD. ALL FASTENERS TO BE CORROSION
RESISTANT. FASTENERS SHALL BE INSTALLED AT 12" PARALLEL TO ROOF SLOPE AND 12" O.C.
PERPENDICULAR TO ROOF SLOPE.
ROOFING ATTACHMENT nts...
PER FL# 11651.12
METAL ROOF PANELS SHALL BE SECURED TO THE SUPPORTS IN ACCORDANCE WITH THE
APPROVED MANUFACTURER'S FASTENERS. METAL PANELS SHALL BE ATTACHED PER
MANUFACTURER'S SPECIFICATIONS AND DETAIL THIS SHEET.
UNDERLAYMENT SHALL BE INSTALLED AS PER MANUFACTURER'S INSTALLATION GUIDELINES
UNDERLAYMENT SHALL BE APPROVED 30# ROOFING FELT.
UNDERLAYMENT APPLICATION.
UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER. UNDERLAYMENT
SHALL BE APPLIED PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2INCHES (51
MM), FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN THE UNDERLAYMENT
SHALL NOT INTERFERE WITH ROOF PANNEL INSTALLATION.
FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING
THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE -PERMEABLE
MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS
THROUGH THE ROOF PLANE. ALL FLASHING SHALL BE IN ACCORDANCE WITH FLORIDA
BUILDING CODE
FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER
THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE
FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS NOT
LESS THAN PROVIDED IN FBC TABLE 1503.2. THIS REQUIREMENT DOES NOT APPLY TO HIP AND
RIDGE JUNCTIONS.
ALL ROOFING INSTALLATIONS SHALL BE IN ACCORANNCE WITH FBC 2014.
ROOFING/UNDERLAYMENT PER
PLAN -
2 X 4 X" BRACING AT RIDGE AND 19/32" ROOF SHEATHING
6 FEET O.C. EACH SIDE OF RIDGE ALUM. DRIP EDGE
-� - 1X P.T. WOOD FASCIA
y
OFFII PER DETAIL
(3)- 16d NAILS (TYPICAL)
2X4 LADDER FRAMING AT
—
12 INCHES O.C.
— GABLE END TRUSS
1 X 4 SPRUCE OR BETTER
HARDIE PER
LATERAL BRACE AT 6 FEET O.C.
_
STRUCTURAL NOTE #
FASTENED TO TOP OF BOTTOM
CHORD OF TRUSSES WITH (2) - 16d
GABLE END FASTENED TO
NAILS EACH, AT GABLE END
— SLEEPER WITH 16 D COMMON
TRUSS AND 4 TRUSS98 BACK
I NAILS AT 12" O.C.
STRAP GABLE END TRUSS WITH
ih
— "SIMPSON" LSTA 15 AT 48" O.C.
CV
WITH (12),- 1 Od X I %" NAILS
TOP PLATE
CEILING PER PLAN i
P.T. 2 X 8 CONTINUOUS WITH V3"
LAG BOLTS AT 24" O.C. WITH
2" X 2" X 1 /8" WASHERS
REINFORCE EACH VERTICAL
MEMBER OF GABLE END TRUSS
WITH 2 X 4 T- BRACE WITH 16 D PLAN VIEW T-SRACE t
NAILS AT 8 INCHES O.C.
GABLE END DETAIL, DtS...
File Copy
ELECTRICAL NOTES
1)
ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70)
2011 EDITION.
2)
RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN
CONDITIONED AND UNCONDITIONED SPACES.
3)
SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP - ARC FAULT CIRCUIT
4)
SMOKE DETECTORS TO BE LOCATED AS SHOWN, AND INSIDE AND OUTSIDE OF
ALL EXISTING BEDROOM INTERIOR DOORS (NOT SHOWN) IF NOT EXISTING
VERIFY.
5)
SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE
DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE
6)
PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS
SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS,
LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS.
7)
PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-
VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS,
GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF
EDGE OF ANY SINK.
8)
EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT.
9)
PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS.
10)
TIE ELECTRICAL INTO EXISTING ELECTRICAL SERVICE.
r L-, HIV 'J4 n 4CA L F
ELECTRICAL LOAD CALC'S
PER NEC
2093 S.F. @ 3 VA
TWO 20A APPLIANCE CKTS
LAUNDRY
DRYER
RANGE
WH
DW
WP TUB (OPTION)
REFRIG
IRR. PUMP (OPTION)
MISC
TOTAL
FIRST 10 KW @ 100%
REMAINDER ()a 40%
TOTAL
A/C HEAT (a) 100%
TOTAL
37071.6
240 = 154 AMPS
USE EXISTING 200 AMP SERVICE
PAUL, WEL cH we
1N$CHANICAL ELECTRICAL CIVIL LrJVGINEER/NG
1984S.W. SILTMOREST. SU/TE# f 14
PORTST, LUCIE, FL 24984.
PHONE (772d 785-9888 E-1AIL PINELCHINCLEDAOL.CO/N
PAUL WELCH, P.E. FLA REGNO.29945
6279 VA
3000
1500
5000
12000
4500
1200
1200
1200
1800
10000
47679 VA
10000
15071.6
25071.6
12000
37071.6 VA
MAIR`2 1.2017