HomeMy WebLinkAboutProject Information i- PLANNING & DEVELOPMENT BOARD OF SERVICES DEPARTMENT COUNTY COMMISSIONERS Building and Code Regulation GAS PIPING SCHEMATIC MAR 2 4 2017 PERMITTING St. Lucie'County, FL tA2] [A4] [A�] [L4] [I$] [L12] TANK Li 1,3 L5 L7 L9 SIZE ST. LUClE COU?VTY BUILDING DIVISION L2] [L6] [Lg ] REVIIE{I41'tED- � FOR COMPLII E REVIEWED BY //_ ►►►' [Al] [A3] [A5] DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE TANK SIZE: `�M/ GALS. / b3 - 0 :3111 APPLICANCE-TYPEISIZE Al Umdib pow _BTU A-1 Gty-u g qw-w ►aTu A3�@q S . 2.�0 -BTU tW WC) MIS BTU �'L - A4 RA --- Lc o,QQC) BTU A6 t ifi�p c, STU PIPING LENGTH &SIZE (PIPE SIZE WAS TAKEN FROM L1 FT. INCH DIA:PP THE 2010 FBC FUEL \GAS CODE— L2 4 FT. �� INCH DIA.-> %TABLE402 1­3 J FT. I INCH DIA.PG i q ryrjC � L4 alse , FT. '' INCH DIA.059f L5 t&5- FT. . It. INCH DIAOSSY _ L6 67(® FT. INCH DIA.d-P I Lt 1 y L7 1�t) FT. it, INCH DAM- p L8 FT. 31q INCH DIA.P►r- L9 FT. INCH DIA.Pa L10 FT. INCH DIA. L11 FT. INCH DIA. L12 FT. "INCH DIA. Website:my-olucieco.aov 2300 Virginia Avenue-Fort Pierce,FL, 34982-5652 Phone(772)462-1553 FAX(772)452-1576 Revised 7/22/14 OT 00,000 Sr fro PAW �' - _ ' dJ i 1 PROPERTY LINE - SEE SURVEY 20' SETBACK LINE i JJ.........._.... % —r-------------J-------- --- ----------------- ---- -- __ -- —r-------------------- ..-. ...f•..� ... O�: ,�! scrnc erjamrn=' I --_..� � PROP. 2 STORY CBS ESIDE CE i IN � l �• j t t! f _ 1 tt �w�se+a�ar otnca� 5'-0" z EMM.:::...... 10, cr- n W DECK ' 1 t r DECK = "t Pr E 1 s � 20' A i K LINE -- i ~" 1 NOTE: SEE SURVEY FOR CO ORD AT OF PROPOSED ESIDENGE 1 _.._.._.��_ .._.._.._-.—..__. .._.._.._. �..__._.._.._.._.._.. .._.._.. _.._. Ir V 1A 1 :32 T AL ARCHITECTURE POOL 051 PA,P(�l it 4m Oil 0.1101 SO (Dq PARl I —T ,p-r- El AT R.A -IT_�IA ................. IT Oi OFFICE ID P'l- C, 0 1-RD-N 2- FAMILY ROOM P,% F < LLJ W-. an __j _j STORAGE 11514 11 Lj- nr ti �al -3 ID z --24-7 Lj ----------- G HALL Ld V) `HALL � I BEDROOM 2 < ------ U- DINING ----- uj (_0 Cf) ----------- ENTRY PATIO 11 101 0 a LLJ 0 0 3 CAR GARAGE o gL----------- 3L, tt ----------- ! oo ----- ------- 22-Mar-17 Confined Space/Combustion Air Calculation Address 12132 Riverbend Rd Total Room Appliance Btu's Required Required Rooms Rooms sizes in Air Avail Air Calc Air in calc Dimmension Calc Cf vol Range 100,000 100,000/1000 x50 5000 Kitchen/FM Rm 32' x 20' x 10' 6400 No Makeup Air Required for Range Dryer#1 22,000 22,000/1000 x50 1100 1st fir laundry 14' x 6' x10' 840 Makeup Air Required for Dryer Dryer#2 22,000 22,000/1000 x50 1100 2nd fir 15' x 13' x 10' 1930 NO Makeup Air Required for Dryer I /^ Yable .P-1 Propane Low-Pressure. (Standard) Maximum.Capa dlty of Omega Flex TracpipeTM in Thousands of BTU per Hour propane Gas' Gas Pressure: 11 in. W.C. Pressure Drop: 0.5 in. W.C. (based on a,1.52 Specific Gravity Gas) del c � 0 1 / � � o . 1 � :o • 0 0o r o0 0 00 15 99 69 55 49 42 39 33 30� 26 1 25 23 22 20 15` 14 12 11 19 211 150 121 106 94 87 74 66 60 57 52 50 47 36 33 30 26 25 456 _ 325 267 232 209 191 166 149 136 126 118 112 106 87. 76 68 62. 31 . . 863 605 490 425. . 379 344. _ -207 265 241 222 208 197 186 143 129 117 107 . �'. 37 1424 971 775- 661 583 529 449 397; : 359 330 307 286 270 217 183 163 147_.; 46 2830 1993 1623 1404 1254 1143 . 988 884 806 745. -,696 656 621 506 438 -390 357 62 6547 4638 3,791 _ 3285 -2940 2684. 2327 2082 1902 1-761 1647. . 1554 1475 1205 1045 934 854 see notes below* EHD(Effective Hydraulic Diameter)A relative measure of tow Capacity;This number is used to compare individual sizes between different manufacturers.The higher the EHD number the greater flow capacity of the piping. �. Table P-2`Propane Medium Pressure Maximum Capacity of Omega Flex TracPipe in -housandls of BTU per Flour.Pr®pane Gas Gas Pressure: 112 psi (12-14 in.W. C-) Pressure Drop: 2:5 tn. W. C. (based on a 1.52 Specific Gravity Gas) 15 ",222 159 "131 ,•,1„14W%�, 3',' �81 67 62 58?�. . ' 55 ` .52 491209 1$ 164' :T :1�50 - . 140 '.`'13 124 1,1 a,; 97, 85 76 70 4 1.9 ; = 1094 782 642 S59 304 285E 26956 2w1.0 183.. . .164 136 2S 501, '`` 459 399' 35828 31 2512 1863 . 1720 1343 1106 976 83` 825 771 719 673 632• 596; 470 39& 352 320 s 37 3476L-236e. 1891 1612 1424 1288' 104% 971 877 805 748 " 700; 661.; 528 44$ 397. 359: 46 63833663 2580.. 2230: 1993 1818 1682 1571: 1481: ' 1.404 1143 988 884 805621458 8443,' 7317 '6547 5980 . 5183 4638 4236 923 3671 ;. 3462. .E32$5 2684 2327 $2 1902 ES:Tables above"include losses for four 90 de ree fiends and two;end fltflngs Tubing runs wl�h larger numbers of bends°andtor fFttings shall°be Increased by.an ant,length gf'tubing;to the following 'NOT. g egriatlodrL�l.3n hrhere L to additional length of tublag end a Is,the number of additFdnaLfittings a}ld/or bends —J � t 0 � s> � Quality Steel Corporation AG/UG Propane Tanks OVERALL LENGTH Q � OVERALL HEIGHT LEC WIDTH ACING�LGG� LEG WIDTH 1-- 1450 wg. AND OF APPROXIMATE ABOVEGROUND/UNDEGROUND(AG/UG)VESSEL DIMENSIONS AND SPECIFICATIONS WATER DIAMETER HEAD OVERALL OVERALL LEG* LEG** WEIGHT **QUANTITY CAPACITY (OD) TYPE LENGTH HEIGHT WIDTH SPACING (lbs.) FULLLOAD PERSTACK *120 wg. 24" Ellip. 5'-8" 3' V-1 1/2" 2'-101/2" 260 108 196 16 112 *250 wg. 30" Hem!. 7'-10" 3'-8" 1'-5" 4'-11" 480 54 9 *320 wg. 30" Hemi. 9'-7" 3'-8" 1'-5" 5' 620 45 9 500 wg. 37 1/2" Hemi. 10' 4'-2" V-8" 5' 950 37 130 8 6 1000 wg. 41" Hemi. 16' - 4'-5" V-8" 11'-9 1/2" 1,800 17 115 6 5 1450 wg. 46 1/2" Ellip. 17'-4" 4'-11" 1'-9" 11'-7" 2,650 .___ 12 4 1990 wg. 461/2" Ellip. 23'-11" 4'-11" V-9" 16' 3,520 8- 4 Dimensions and specifications shown are approximate. Individual vessels may vary. •Leg spacing+/-2". Leg widths and spacing may vary based on mfg.location. Check with your salesperson for details. 120,250,320 wg.standard tanks no holes in legs(one center hole on request). 500 and 1000 wg.standard tanks-2 holes 16"on center. 1450 wg.and up as shown above. Full load and stack quantities vary by shipping location. Check with your salesperson for details. General Specifications -Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels,Section Vill, Division 1. Complies with NFPA 58. -Rated at 250 psig from-20° F to 125° F. All vessels registered with National Board. -Two service options available: Option 1: Ready-to-bury underground option,coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat,supplied with composite AG/UG dome. Option 2:A'ioveground option,coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane top coat,supplied with steel AG/UG dome. -All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel. Updated January 14,2015 y` PROPANE CONSTRUCTION NOTES 1. All pipe and fittings above ground and inside building shall be SCH. 40 Galvanized ASTM A120 or AGA approved corrugated stainless steel (C.S.S.T.) pipe. 2. All polypipe and fittings shall be ASTM D2513 or ASTM D2517 and shall be buried-outside underground at a depth of 18" with g P warning tape and tracer wire. 3. All pipe and meter locations are approximate and subject to change. 4: All polypipe shall be joined by heat fusion or approved mechanical couplings. 5. AlFgalvanized pipe shall be threaded. 6. All pipe shall be pressure tested to 20 # PSI for a period of 24 hours. 4 • '^:fig:•. . i tep UNDF-A ROUND TANK INSTALLAT1014 ' 2" bo O-. DOWNGRADED AWAY FROM DOME �• ___it W-- ' •Mle"t a26 I ANODE CABLE '�'• SACRIFICIAL ANODE (MAGNESIUM 9A,GI �•� •� ` ftum'Ai'GR 1, SHUT GA'S OFF AT ' -U SIDE VALVE 'f�•x IR71OVE GRADE i►+ • ~• NARN 110 TAPE R' �O Yr RISE GRADS/CONCRETE SLEEVE 1 .0�, �•• •;:,••�•O• �. • J•I.off• • Jr f• 11� I•'+�.0• }••� of 'p si• �• •�..� e,•o o f• rJll o `a a UHD2gO110V1101F0Af 001111UHER •SERVICE LINE `D rH' TRACE HIRB _ IS it1�►UlrfiCr'il l^:ti!•�iil-w 1�� •I f i"I -111"'(Is alw��nnrDw+ •