HomeMy WebLinkAboutRevisions OFFICE USE ONLY:
DATE FILED: -4 PERMIT# SLC-1703-0519
REVISION FEE: C RECEIPT#
µ. PLANNING & DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION ��� 3 ���
0 2300 VIRGINIA AVENUE PERIAIT MG
FORT PIERCE,FL 34982-5652 St. Lucie County, FL
(772)462-1553 FAX(772)462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/S T
ADDRESS: l Beach Avenue, Port St Lucie
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Installation of self adhered underlayment,Polyglass IR-X FL 5259-R24, in lieu of 301b felt.
Backtag 12"OC.'
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: CCC1326574 Inc. LUCIE COUNTY CERT.#: 23041
BUSINESS NAME: Code Red Roofeis
QUALIFIERS NAME: SE Slater Douglas Roe
ADDRESS: 333
CITY: Stuart STATE: ZIP:
PHONE(DAYTIME): - 7-2829 FAX: 772-287-7763
4. OWNER/BUILDER INFORMATION:
NAME: A I
ADDRESS:
CITY: S
PHONE: }`
S. ARCHITECT/ENGINEER INFORMATION: , = r
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
Revised 07/22/2014
R 0 N
i
FloridadBuild i, g Code 0n ine . Page.1 of.2.
-
KY
�/s
i10,6"J'a0T,3 tmPnt ` 6CIS Home ;Log;in { U,ser'Regisrraticn ? Hot_Topics Supm t5urctafg. z.SOts a F.,ects; -Pubifcat!ns MC:Staff 5'BclS site.mao links .ttard,
t� f �
_ a
1f�1�y�' TTff�`IppJ�CC�' Rroduc#Approval Lkt-
1 10i_L�J.I .a�#.(l;5 .PubixUser
e, ula.fll n ®ryp��ygp ep9�
>G�tFlLcetl�.: =>.;APPlicatiorr Detail A R 13 2017
jj U FL* FL5259-R23 PERRMITTIN IGa
Application:Type Revision St. Lucie County, FL
Code Version 2014
Application,Status 'Approved
Comments 04/27/2015
Archived `:
Product Manufacturer PO.LYGLASS USA
Address/Phone/Email. 150 Lyon Drive
Fernley;NV 89408
(.570),384-123,0 Ezt242
jaldns@polyg lass,eom
Au6orized Signature James Akins:
jabns*c'lyglass,com.
Technical Representative sieve Wadding
Address/Phone/Email, .150'.1-yon Drive
'Fernle 6s y,NV:98408
(602)3 -:7139
stevew @po I yg lass.eo m
Quality Assurance'RepresentatlVe: James'.Akiris:
Address/Phone/Email 555 Oakrldge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800).894-4563
j a ki n s'@P o f yg l a ss,co m
Category- Rocifing
Subcategory U nderiaymeets
Compliance Method" Evaluation Report'from a Florida Registered-Architect`ora Licensed
Florida Professional Engineer
Evaluation"Report-Hardcopy;'Recelved
Florida Engineer or Architect Name who developed �`�Nle �e r
the Evaluation Report OC U FASTENERS On ATTACHMENTS
Florida License P 59 6 I IE RESPONSIBILITY OF THE
Quality Assurance'Entity U Lb� a , 1 RESPONSIBILITY [[�� i tl
Quality Assurance Contract Expiration.Date 0 /A2 0{�l77" TRACTOR OF YYEb4Jrll
Validated By J n W:I( ezevic E
va rdahec Istc
L r
Cerfificate:of.19dependence FLS259 k..a 4t?T 015 01 C4I Nlemrnen.odf
Referenced.Standard and Year-(of Standard), Standard Year
ASTM(� 131976 2009 ASTM ET SE PLANS AND ALL PROPOSED WORK 2006
`ST.LUCIE CO ?jTY BUTLDLNG mm iT ASTM Aftg,SUBJECTTO ANY CORRECTIONS 20g5
REVIEWED FOR C " ASTMgYIRED 8Y FIELD INSPECTORS THAT Zoos,
REVJEIVI ASTM.Mg BE NECESSARY IN ORDER TO 2oo6
DATE aStm;( QMPLY WITH ALL APPL.ICAMS GODEtiS. zoos
TLANS f R-.NIIT MUST BE KEPT ON JOB FM 4474 2004
OR NO INSPECTION WILL BE I LUL n
f11F littp !'m �%tloridaliu lding:er r'pr/prJapp_1.aspx`?param=wGEVXQ,"!Dc1�TUS.gAaZp3Crl:2 7I2/2015
Florida Building Codz 01AMi Page.2 of 2.
FRSA/TRI•Aprif 20:12"> 2012
TAS,103! 1995
Eq ulyalence;of.:Product:5tandards
Ceitifletl By
Sections from:the'Code
Oro
duct Approyal.Method, _ Ptetho4"10ptlon D
bate Submitted A4/24j2015
Date:ValidaEed 05/01/20Y5
gate;Pending FBC Approval OS/03/2015
Date Approved 06/23/:615
5uin'riary of.P'roducts
FL O. Model,Number or Description
Name
5259 f Polyglass Roof. Roofing iinderlaymen
,Undetla.yments'
Limitslof Use Instaliation Instructions
Approved for use'in HVHZ: No FL52s9 R23 II 2015•n5 FINAL Es POLYGLASS UNDERLAYMENTS FL52S9-
PR ,
Approved,For use outside HVk2'Yes R23.ndf
Impact kesistant:•.N/A Verified`Byi:,Robet Nientinert PE-59166
D"estgn,::Pressure::+NJA/=522.5; Created by':IndependeritThird::Party:Yes;
Other: 1.)The design pressure.in this Evaluation Reports
application,relates to one particular �L52S9;_R�3_AEOSS_Q5_EIPIAL_EliPQLYGLAS5 UNDEPLAYPIENTS FL5259_,
underiay'mentsystem(over concrete R23_pdf'
deck)for use under foam-on tile'systerns Created by Independent Third Patty::Yes
(where the underlaynlent-forms part of
the oad-path)'.Refer to ER Section,5;6.4
for other.systems;other deck.types and
assoclated maximum design`'pressures:
2.)Refer to-ER.Sectlon,5 forother limits
of use.
fa�u near
Ccmacttj i94o North-Monroe-"Streer:Tallahassee F 3y_2399 Phone::9SQ-48'JLP,
Tnz�tai:?_of Florida is.an A�'EEO emplgyeg_Jj7ynotit:z007-201:3State of.Etcr'da ;;,FnuaeV Statenient,:NccesslEu4tvSra Cement-:�I:ei�ratStatemeot
- ;Under Floridan lewrr email atldresys are:pt.fillcYOcords lP you 4o,not want yaik e-rrietl add(ess r2fease3 in resporte'N s pudic=re ards'requesp do-ne[serd
electronic mail-to,thls entity:instead,contactthe office by phone.orby:tradilional mall.l f,you:have any giesboiis;pleats tcdn_nSo.487:139S.*Pursuant to
racaon i55.275(1);.Flaida statutes;:effecdvebctcber 1,2012,Ilcensees Ilcensedn.nder Chapter4SS,F.S.mustprhvfde the Departmenrwltfianernai'add'essA
the.y.have one:71ie'emalls provided maybe used.for:ofriclal commurrcatlonwith[he licem o:However email'addi-e as:are.publtcteccrd;Lf You_do"not:w iI h to
supply a personal:eddres,please provltle tF Departm;ntwi h an email address:ivtilch an to made availaae to did pudic,Toidkermine it you are licencee'ur der
. Chapter 455,•F.S.,_please clickaiere.
product Approval;ActtNtsi.
!sCCU]iL4 di i[txi f E r:
s
liitip !Iwww:floridaliu lding orgi:pr%pr_app_dtl.aspx?parain=wGEVXQwtDgvUS.q-AaZ' p3Cr1:2.... 7/2/20.1S
r EXTERIOR RESEARCH&DESIGN, LLC.
Certificate of Authorization#9503
�:.. E�� 353 CHRISTIAN STREET, UNIT#13
TRINITY OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R20
150 Lyon Drive FL5259-R24
Fernley, NV 98408 Date of Issuance:02/24/2009
Revision 20:07/22/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity l ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 12.
Prepared by:
-` = The facsimile seal appearing was authorized by Robert Nieminen,
P.E.on 07/22/2015. This does not serve as an electronically
signed document. Signed,sealed hardcopies have been
Robert J.M. Nieminen,P.E. ;,F
s� :.....;�.�:
Florida Registration No.59166,Florida DCA ANE1983 =!��„�;4a1«+'` transmitted to the Product Approval Administrator and to the
named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
" INI TY ERD
1
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1504.6 Accelerated Weathering ASTM G154 2006
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006
1507.8.3,1507.9.3
1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009
1507.11.2 Physical Properties ASTM D6164 2005
1507.11.2 Physical Properties ASTM D6222 2008
1507.3.3 Installation Practice FRSA/TRI April 2012 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000
PRI(TST5878) Physical Properties PRI01111 04/08/2002
PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002
PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002
PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003
PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005
PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006
PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006
PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007
PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008
PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008
PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009
MTI(TST 2508) Physical Properties JX20H7A 04/01/2008
MTI(TST 2508) Physical Properties RX14E8A 01/29/2009
ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003
ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007
ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008
ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009
ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009
ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010
ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 2 of 12
\ TR1N1TY ERD
I
Entity Examination Reference Date
ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD(TST 6049) Wind Uplift PLYG-SC8905.15 07/22/2015
]CC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/LAffidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation,R14571 Exp.08/08/2015
UL,LLC.(QUA9625) Quality Control Service Confirmation,MTS PLUS Exp.07/01/2017
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet.
4.2 Self-Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly-film surface;meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane,glass-fiber/polyester reinforced,
with a granular surface;meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and TAS 103.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-1120
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 3 of 12
Fi:_R�JNJTYJERD
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets;meet ASTM D6222.
4.2.8 Polystick Dual Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.9 Polystick Tile Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164.
4.3.2 Polyflex G and Polyflex G FR are polyester reinforced,APP modified bitumen cap sheets; meet ASTM D6222.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1:Rood COVER OPTIONS
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal wood Shakes& Slate
Shingles
Yes Yes
Elastobase Yes (base layer in 2-ply (base layer in 2-ply Yes Yes Yes
system) system)
Yes Yes
Elastobase P Yes (base layer in 2-ply (base layer in 2-ply Yes Yes Yes
system) system)
Polystick MTS Yes Yes No Yes Yes Yes
Polystick MTS PLUS Yes Yes No Yes Yes Yes
Polystick IR-Xe Yes No No No Yes Yes
Polystick TU P Yes Yes Yes No Yes Yes
See 5.5.1
PolystickTU Plus Yes Yes Yes Yes Yes Yes
See 5.5.1
Polystick TU Max No Yes Yes Yes No No
See 5.5.1
Polystick Dual Pro Yes Yes No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes Yes Yes Yes
See 5.5.1
Elastoflex S6 G Yes Yes Yes No Yes Yes
See 5.5.1
Elastoflex S6 G FR Yes Yes No No Yes Yes
Polyflex G Yes Yes Yes No Yes Yes
See 5.5.1
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes
See 5.5.1
Mule-Hide SA-APP Cap Sheet Yes Yes Yes No Yes Yes
or SA-APP Cap Sheet(FR) See 5.5.1
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 4 of 12
QYOTRINITYIERD
5.5.1 "Foam-On Tile' is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging
data from an accredited testing laboratory is provided.
✓ 3M` 2-Component Roof Tile Adhesive AH-160 (FL6332): Polystick TU P, Polystick TU Plus, Polystick TU Max,
Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP
Cap Sheet(FR)or Tile Pro.
✓ 31VI'"' Foam Roof Tile Adhesive RTA-1 (FL6276): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6
G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
or Tile Pro
✓ Dow TileBond(FL717): Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
✓ Convenience Products'Touch 'n Seal Storm Bond Roof Tile Adhesive (FL14506): Polystick TU Plus, Polystick TU
Max
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
' Note:Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch-applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyan u rate or Type V polyisocyanu rate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or G FR torch-applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 5 of 12
TRI! ITY ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or
Tile Pro self-adhered to:
➢ ASTM D226,Type I or II felt; Elastobase; Elastobase P or Mule-Hide Nail Base.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ ASTM D226,Type I or II felt; Elastobase; Elastobase P or Mule-Hide Nail Base.
Polyflex G or G FR torch-applied to:
➢ Elastobase; Elastobase P or Mule-Hide Nail Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A,Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
5.6.4.1 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.2 Maximum Design Pressure=-135 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)PG100 or ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.3 Maximum Design Pressure=-315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.4 Maximum Design Pressure=-622.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: PG 100 or ASTM D41
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.5 Maximum Design Pressure=-30.0 psf*.
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 6 of 12
TRINITY+ ERD
5.6.4.6 Maximum Design Pressure=-37.5 psf*.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.7 Maximum Design Pressure=-37.5 psf*.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.8 Maximum Design Pressure=-45 psf*.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: ll,ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.9 Maximum Design Pressure=-45 psf*.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.10 Maximum Design Pressure=-45 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.11 Maximum Design Pressure=-52.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.12 Maximum Design Pressure=-52.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-1124
Revision 20:07/22/2015
Page 7 of 12
FTINITY I ERD
5.6.4.13 Maximum Design Pressure=-52.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.14 Maximum Design Pressure=-60 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.15 Maximum Design Pressure=-60 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.16 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.17 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roof grip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
g P Y Y
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.18 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.19 Maximum Design Pressure=-97.5 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max, Polyflex SAP,Polyflex SAP FIR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FIR),self-adhered.
5.6.4.20 Maximum Design Pressure=-105 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
Exterior Research and Design,LLC. Evaluation Report P32060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 8 of 12
�,t YR.INI` Y ERD
5.6.4.21 Maximum Design Pressure=-112.5 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.22 Maximum Design Pressure=-120 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: CMG#12 Standard Roofgrip or CMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.23 Maximum Design Pressure=-120 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.24 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
5.6.4.25 For mechanically attached base sheet in a 2-ply system,the maximum design pressure for the selected assembly shall
meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12),Appendix A,
Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional
to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone
2/3 enhancements.
5.7 Exposure Limitations:
Elastobase or Elastobase P shall not be left exposed for longer than 30-days after installation.
Polystick IR-Xe shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 180-
days after installation.
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180
d ays.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-1120
Certificate of Authorization#9503 FL5259-1124
Revision 20:07/22/2015
Page 9 of 12
QTRINITYIERD
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and(lashings
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR), Dual Pro or Tile Pro,self-adhered, Elastoflex S6 G or S6 G FR in
hot asphalt or Polyflex G or G FR,torch applied.
6.3.3 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
6_4 Polystick MTS,MTS PLUS,IR-Xe,TU P,TU Plus,TU Max Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-
APP Cap Sheet(FR),Dual Pro or Tile Pro:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers:
All self-adhering materials,with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap
Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-Hide
Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter
metal disk or Simplex-type metal cap nail,at a minimum rate of 12"o.c. Polystick TU Plus should be back-nailed using
the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The
head lap membrane is to cover the area being back-nailed
All seal-lap seams (selvage laps) must be - •
firmly rolled with a minimum 28 lb. hand s
roller to ensure full contact and adhesion. _
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern;
(the sheet will overlap the fabric). ;,-
View of Ovelap Seam of Dual Pro and Tile Pro
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-1120
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 10 of 12
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps(min.28 lb roller)or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications(not allowed for Polystick IR-Xe):
Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein,using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of base sheet and self-adhering top sheet(s), base
sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.6.4 herein.
For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
For nail-on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.4.4 Two(2)Ply Underlayment SVstems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus,TU Max, TilePro or Polyflex SAP is
allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the
top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P, TU Plus, TU Max, TilePro or Polyflex SAP is allowable for use under
foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S6 G or S6 G FIR:
6.5.1 Elastoflex S6 G or S6 G FIR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications,reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein.
6.5.2 Elastoflex S6 G or S6 G FIR shall be fully asphalt-applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end
laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge.
6.6 Polyflex G or G FIR:
6.6.1 Polyflex G or G FIR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications, reference is made FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein.
6.6.2 Polyflex G or G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-
inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be
fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards,to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail-on tile systems over Polystick MTS, battens are required for loading/staging of the tile.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-1120
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 11 of 12
W., TRINITYERD
6.7.4 For nail-on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight
(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625;(314)578-3406; k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 12 of 12